E
MATERIAL
MATERIALE
SCALE
SCALA
Kg/mm²
HRC
mm
PESO
WEIGHT
TREATMENT
DATA
DATE
CONTROLLATO
CONTROLLED
DATA
DATE
DISEGNATO
DRAWN
UNI
A2
FOGLIO / SHEET
Documento riservato a termini di legge con divieto di riproduzione e divulgazione / Legally private document. All rights reserved
LUNGH. ANGOLI SMUSSI RAGGI
LENGTH ANGLES BEVELS RADIUS
UNI-ISO 2768 m
Kg
TOLLERANZE / TOLERANCES RESISTENZA STRENGTH
TRATTAMENTO
DUREZZA HARDNESS
ALBERI
SHAFTS h13
PROFONDITA' DEPTH
FORI
HOLES H13
DENOMINAZIONE
DENOMINATION
SOSTITUISCE IL
REPLACE THE CODICE
CODESOSTITUITO DAL
REPLACED FROM
C
B
A
IND. MODIFICA / MODIFICATION DATA / DATE SIGLA / NAME
544±12352
200235164
599
850
10069456
1013
780120
DN 25
#300
LIGUID GPL
GAS OUT
599
661
434
410
210
365
82
332100362
62
1
2
3
4
5
6
7
8
9
10
11
12
Ex
PEGORAROGAS INNOVATIVE TECHNOLOGIES
PEGORARO GAS TECHNOLOGIES S.R.L., VIA ENRICO FERMI, 253, 36100 VICENZA (VI), ITALY
0948
VAPORIZZATORE GPL - LPG VAPORIZER
HEATER ACC. DIR. 2014/34/UE ATEX II 3 G T5
PORTATA
FLOW RATE
TIPO
TYPE
N.F.
SERIAL N.
PED CAT.
ANNO
YEAR
PESO
WEIGHT
Kg
PRESSIONE MAX AMMISS.
MAX ALLOW PRESSURE
PS
LATO GAS
GAS SIDE
bar PS
LATO ACQUA
WATER SIDE
bar
PT barbarPT
PRESSIONE DI PROVA
TEST PRESSURE
TS °C°CTS
TEMPERATURA MIN/ MAX
TEMPERATURE MIN/MAX
V llV
VOLUME
CAPACITY
FLUIDO GRUPPO I
FLUID GROUP I
FLUIDO GRUPPO II
FLUID GROUP II
TENSIONE
VOLTAGE
V
POTENZA
POWER
kW
TARATURA VAL. SIC.
SAFETY VAL. SET PRES.
bar
kg/h
20
30
-40/+120 -10/+105
18
50
8 380
2018
EV2
I
3
4.5
Voltage ON
Heater ON
Heater Allarm
General Switch
Low water level
ON/OFF Button
ELECTRIC PANEL IP 65
GassensinelineWatersensineline
DN 25
#300
* Livellostato Opzionale/ Optional Level Gauge
110
36100 VICENZA (VI) ITALY
Tel. +39 0444289382
www.pegorarogas.com
L.P. 18/05/2018
1 /
Z:Disegni3D BLOCCHILIBRERIAECOVAPECOVAP 50EA36040041_ ECOVAP 50E_380V_External Use
00
1:8 S.C.
36040041
VAPORIZZATORE GPL ELETTRICO 8KW 380V 3PH
ECOVAP T 50 KG/H - ELECTRIC GPL VAPORIZER 8KW
380V 3PH ECOVAP T 50 KG/H
18/05/2018
1

Ecovap 50 kg elettrico - Ecovap 50 kg electric

  • 1.
    E MATERIAL MATERIALE SCALE SCALA Kg/mm² HRC mm PESO WEIGHT TREATMENT DATA DATE CONTROLLATO CONTROLLED DATA DATE DISEGNATO DRAWN UNI A2 FOGLIO / SHEET Documentoriservato a termini di legge con divieto di riproduzione e divulgazione / Legally private document. All rights reserved LUNGH. ANGOLI SMUSSI RAGGI LENGTH ANGLES BEVELS RADIUS UNI-ISO 2768 m Kg TOLLERANZE / TOLERANCES RESISTENZA STRENGTH TRATTAMENTO DUREZZA HARDNESS ALBERI SHAFTS h13 PROFONDITA' DEPTH FORI HOLES H13 DENOMINAZIONE DENOMINATION SOSTITUISCE IL REPLACE THE CODICE CODESOSTITUITO DAL REPLACED FROM C B A IND. MODIFICA / MODIFICATION DATA / DATE SIGLA / NAME 544±12352 200235164 599 850 10069456 1013 780120 DN 25 #300 LIGUID GPL GAS OUT 599 661 434 410 210 365 82 332100362 62 1 2 3 4 5 6 7 8 9 10 11 12 Ex PEGORAROGAS INNOVATIVE TECHNOLOGIES PEGORARO GAS TECHNOLOGIES S.R.L., VIA ENRICO FERMI, 253, 36100 VICENZA (VI), ITALY 0948 VAPORIZZATORE GPL - LPG VAPORIZER HEATER ACC. DIR. 2014/34/UE ATEX II 3 G T5 PORTATA FLOW RATE TIPO TYPE N.F. SERIAL N. PED CAT. ANNO YEAR PESO WEIGHT Kg PRESSIONE MAX AMMISS. MAX ALLOW PRESSURE PS LATO GAS GAS SIDE bar PS LATO ACQUA WATER SIDE bar PT barbarPT PRESSIONE DI PROVA TEST PRESSURE TS °C°CTS TEMPERATURA MIN/ MAX TEMPERATURE MIN/MAX V llV VOLUME CAPACITY FLUIDO GRUPPO I FLUID GROUP I FLUIDO GRUPPO II FLUID GROUP II TENSIONE VOLTAGE V POTENZA POWER kW TARATURA VAL. SIC. SAFETY VAL. SET PRES. bar kg/h 20 30 -40/+120 -10/+105 18 50 8 380 2018 EV2 I 3 4.5 Voltage ON Heater ON Heater Allarm General Switch Low water level ON/OFF Button ELECTRIC PANEL IP 65 GassensinelineWatersensineline DN 25 #300 * Livellostato Opzionale/ Optional Level Gauge 110 36100 VICENZA (VI) ITALY Tel. +39 0444289382 www.pegorarogas.com L.P. 18/05/2018 1 / Z:Disegni3D BLOCCHILIBRERIAECOVAPECOVAP 50EA36040041_ ECOVAP 50E_380V_External Use 00 1:8 S.C. 36040041 VAPORIZZATORE GPL ELETTRICO 8KW 380V 3PH ECOVAP T 50 KG/H - ELECTRIC GPL VAPORIZER 8KW 380V 3PH ECOVAP T 50 KG/H 18/05/2018 1