2. Agenda
Day 1 - 24th Sept
Hardware architecture including development environment
Hardware spec
Storage Solution and Architecture
HADR Implementation
Day 2 - 25th Sept
Data warehouse architecture (keep very much an as is for migration)
OS design
Back-up process
Migration plan
3. Hardware Architecture
Outcomes required on completion
Confirm that architecture will support future plans
Confirm that we are not doing anything out of the ordinary /
following best practice
Sign off final high level plan
4. Hardware Architecture
High Level Hardware Architecture - Phase 1
Physical Server - A
Virtual Machine - VMUKTRA1 Virtual Machine - VMUKCUS1 Virtual Machine - VMCTRL1
DB Instance -INUKTRA1 DB Instance -INUKCUS1 DB Instance -INCTRL1
UKWEBP UKREPOP
UKTRANSP UKCUSTP CONTROLP
(Standby) (Standby)
Physical Server - B
Virtual Machine - VMUKWEB1 Virtual Machine - VMUKREP1 Virtual Machine - VMCTRL2
DB Instance -INUKWEB1 DB Instance -INUKREP1 DB Instance -INCTRL2
UKTRANSP UKCUSTP CONTROLP
UKWEBP UKREPOP
(Standby) (Standby) (Standby)
5. Hardware Architecture
High Level Hardware Architecture - Phase 2
Physical Server - A
Virtual Machine - VMUKTRA1 Virtual Machine - VMCTRL1
DB Instance -INUKTRA1 DB Instance -INCTRL1
UKWEBP
UKTRANSP CONTROLP
(Standby)
Physical Server - B
Virtual Machine - VMUKWEB1 Virtual Machine - VMCTRL2
DB Instance -INUKWEB1
DB Instance -INCTRL2
UKTRANSP CONTROLP
UKWEBP
(Standby) (Standby)
Physical Server - C
Virtual Machine - VMUKCUS1
DB Instance -INUKCUS1
UKREPOP
UKCUSTP
(Standby)
Physical Server - D
Virtual Machine - VMUKREP1
DB Instance -INUKREP1
UKCUSTP
UKREPOP
(Standby)
6. Hardware Architecture
High Level Hardware Architecture - Phase 3
Physical Server - A
Virtual Machine - VMUKTRA1 Virtual Machine - VMEUTRA1 Virtual Machine - VMCTRL1
DB Instance -INUKTRA1 DB Instance -INEUTRA1 DB Instance -INCTRL1
UKWEBP EUWEBP CONTROLP
UKTRANSP EUTRANSP
(Standby) (Standby)
Physical Server - B
Virtual Machine - VMUKWEB1 Virtual Machine - VMUKTRA1 Virtual Machine - VMCTRL2
DB Instance -INUKWEB1 DB Instance -INUKTRA1 DB Instance -INCTRL2
UKTRANSP EUTRANSP CONTROLP
UKWEBP EUWEBSP
(Standby) (Standby) (Standby)
Physical Server - C
Virtual Machine - VMUKCUS1 Virtual Machine - VMUKTRA1 Virtual Machine - VMCTRL1
DB Instance -INUKCUS1 DB Instance -INUKTRA1 DB Instance -INCTRL1
UKREPOP EUREPOP
UKCUSTP EUCUSTSP GLOBALP
(Standby) (Standby)
Physical Server - D
Virtual Machine - VMUKREP1 Virtual Machine - VMUKTRA1 Virtual Machine - VMCTRL2
DB Instance -INUKREP1 DB Instance -INUKTRA1 DB Instance -INCTRL2
UKCUSTP EUCUSTP GLOBALP
UKREPOP EUREPOP
(Standby) (Standby) (Standby)
8. Storage Solution and
Architecture
Outcomes required on completion
Decision on Storage solution
Architecture of buffer pools, tablespaces
Confirmation of SAN Disk set-up
10. HADR Implementation
Outcomes required on completion
Method of implementation
Understanding of overhead on existing system
Implementation Architecture