                                    Oakham Primary School, Dudley, West Midlands

Consultant
■   BSD



Client
■   Lord Combustion Limited
                                   Front Entrance



Sector
■ Education



Products
■ DW Flue System
                                   Twin wall flue                      Header System with 30 incline


Equipment                          Airtherm have recently designed, supplied and installed a complete twin wall
                                   stainless steel flue system serving each MHS Adinox ADI LT 200 modulating boiler
                                   at Oakham Primary School in Dudley in the West Midlands.
■ MHS ADI LT
                                   The existing cast iron boilers were removed by the contractor during the School
                                   summer shut-down, working on a tight program the MHS high efficiency boilers
                                   were installed followed by the installation of our flue system. All of the plant was
                                   commissioned in time for the return of the pupils to enter a new begging.
Application
                                   The flue system installed was designed to completely evacuate the products
■ High Efficiency Condensing       combustion taking into account for the over-pressure from each appliance. Each
                                   primary flue incorporated a volume control damper and draft regulator in the event
                                   of unstable operation. The complete system had a 30 fall back to the appliance to
                                   allow condense to vacate and drain from the flue.

                                   Airtherm Engineering Ltd only uses branded products which are synonymous with
                                   the highest quality - and it is this reputation that enables specifiers and contractors
                                   to use our versatile product range with total confidence

                                   We can provide technical solutions for the specialist areas of high temperature
                                   exhaust systems, serving generators & combined heat and powder units, fan
              MHS ADI LT Boilers   assisted, flue dilution and atmospheric applications.


          0844 809 2509 | airtherm.co.uk | info@airtherm.co.uk
Product Solution

                            •   Boilers:             MHS

                            •   Model:               ADI LT 200

                            •   Application:         Chimney / Flue system

                            •   Operating mode:      Wet

                            •   Pressure:            Negative / positive pressure

                            •   Working pressure: 200 Pa (product will operate 1000pa max)

                            •   Inner wall:          316L1.4404/1.457 thickness 0,6 mm

                            •   Outer wall:          304/ 1.4301 thickness 0,5

                            •   Insulation:          30mm thick Rockwool insulation

                            •   Sealant :            Tri-lip 'o' type silicone ring
Airtherm Masterflue         •   Fuel type:           Gas




                            •   Other Application Dinak Flues can be used:
                            •   Condensing boilers

                            •   Atmospheric gas-fired boilers

                            •   Gas blown boilers
Primary Flues
                            •   Industrial ovens, large-scale establishments

 Contact Details:           •   Wood-fired stoves
 Airtherm Engineering Ltd
 Ventilation House
 Pedmore
 Stoubridge
 West Midlands
 DY9 0DS


 Tel: 0844 8092509
 Fax: 01562 887312




              0844 809 2509 | airtherm.co.uk | info@airtherm.co.uk

More Related Content

More from Andy Brown

Single wall chimney brochure
Single wall chimney brochureSingle wall chimney brochure
Single wall chimney brochure
Andy Brown
 
Natural ventilation controls brochure
Natural ventilation controls brochureNatural ventilation controls brochure
Natural ventilation controls brochure
Andy Brown
 
Flues airtherm-
Flues airtherm-Flues airtherm-
Flues airtherm-
Andy Brown
 
Case study for slough police station
Case study for slough police stationCase study for slough police station
Case study for slough police station
Andy Brown
 

More from Andy Brown (20)

Viteous univit brochure
Viteous univit brochureViteous univit brochure
Viteous univit brochure
 
Single wall chimney brochure
Single wall chimney brochureSingle wall chimney brochure
Single wall chimney brochure
 
Masterflue MF Flue & Chimney Brochure
Masterflue MF Flue & Chimney BrochureMasterflue MF Flue & Chimney Brochure
Masterflue MF Flue & Chimney Brochure
 
Natural Ventilation Brochure
Natural Ventilation BrochureNatural Ventilation Brochure
Natural Ventilation Brochure
 
Heat pumps & Renewables
Heat pumps & RenewablesHeat pumps & Renewables
Heat pumps & Renewables
 
Commercial itchen Ventilation
Commercial itchen VentilationCommercial itchen Ventilation
Commercial itchen Ventilation
 
Air conditioning
Air conditioningAir conditioning
Air conditioning
 
Natural ventilation controls brochure
Natural ventilation controls brochureNatural ventilation controls brochure
Natural ventilation controls brochure
 
Flues airtherm-
Flues airtherm-Flues airtherm-
Flues airtherm-
 
Flue dilution
 Flue dilution  Flue dilution
Flue dilution
 
Airtherm twin wall flue systems
Airtherm twin wall flue systemsAirtherm twin wall flue systems
Airtherm twin wall flue systems
 
Airtherm dwhp twin wall flue systems
Airtherm dwhp twin wall flue systemsAirtherm dwhp twin wall flue systems
Airtherm dwhp twin wall flue systems
 
Press release we have moved
Press release we have movedPress release we have moved
Press release we have moved
 
Airtherm hvr-
Airtherm hvr-Airtherm hvr-
Airtherm hvr-
 
Case study for st bernard's
Case study for st bernard'sCase study for st bernard's
Case study for st bernard's
 
Case study for slough police station
Case study for slough police stationCase study for slough police station
Case study for slough police station
 
Case study for elmhurst school
Case study for elmhurst schoolCase study for elmhurst school
Case study for elmhurst school
 
Airtherm flue portfolio
Airtherm flue portfolioAirtherm flue portfolio
Airtherm flue portfolio
 
Flues
FluesFlues
Flues
 
Airtherm grilles & louvre booklet
Airtherm grilles & louvre bookletAirtherm grilles & louvre booklet
Airtherm grilles & louvre booklet
 

Case study for oakham primary school

  • 1. Project Profile Oakham Primary School, Dudley, West Midlands Consultant ■ BSD Client ■ Lord Combustion Limited Front Entrance Sector ■ Education Products ■ DW Flue System Twin wall flue Header System with 30 incline Equipment Airtherm have recently designed, supplied and installed a complete twin wall stainless steel flue system serving each MHS Adinox ADI LT 200 modulating boiler at Oakham Primary School in Dudley in the West Midlands. ■ MHS ADI LT The existing cast iron boilers were removed by the contractor during the School summer shut-down, working on a tight program the MHS high efficiency boilers were installed followed by the installation of our flue system. All of the plant was commissioned in time for the return of the pupils to enter a new begging. Application The flue system installed was designed to completely evacuate the products ■ High Efficiency Condensing combustion taking into account for the over-pressure from each appliance. Each primary flue incorporated a volume control damper and draft regulator in the event of unstable operation. The complete system had a 30 fall back to the appliance to allow condense to vacate and drain from the flue. Airtherm Engineering Ltd only uses branded products which are synonymous with the highest quality - and it is this reputation that enables specifiers and contractors to use our versatile product range with total confidence We can provide technical solutions for the specialist areas of high temperature exhaust systems, serving generators & combined heat and powder units, fan MHS ADI LT Boilers assisted, flue dilution and atmospheric applications. 0844 809 2509 | airtherm.co.uk | info@airtherm.co.uk
  • 2. Product Solution • Boilers: MHS • Model: ADI LT 200 • Application: Chimney / Flue system • Operating mode: Wet • Pressure: Negative / positive pressure • Working pressure: 200 Pa (product will operate 1000pa max) • Inner wall: 316L1.4404/1.457 thickness 0,6 mm • Outer wall: 304/ 1.4301 thickness 0,5 • Insulation: 30mm thick Rockwool insulation • Sealant : Tri-lip 'o' type silicone ring Airtherm Masterflue • Fuel type: Gas • Other Application Dinak Flues can be used: • Condensing boilers • Atmospheric gas-fired boilers • Gas blown boilers Primary Flues • Industrial ovens, large-scale establishments Contact Details: • Wood-fired stoves Airtherm Engineering Ltd Ventilation House Pedmore Stoubridge West Midlands DY9 0DS Tel: 0844 8092509 Fax: 01562 887312 0844 809 2509 | airtherm.co.uk | info@airtherm.co.uk