SlideShare a Scribd company logo
1 of 16
Download to read offline
w w w . d m c m e d i c a l . n e t
DMCM E D I C A L
Bryan Wixted
CEO DMC Medical Ltd. Ireland
Carolyne Deer
Administration Manager, Ireland
Mike Clancy
Product Development Manager, Ireland
Bill Zhang
Quality Engineering Manager, China
Andy Song
CEO DMC Medical Tech. & Mfg. Co. Ltd.
China
Charmaine Henderson
Regulatory Director, U.S.A.
Julie Torres
Customer Service, U.S.A.
Transportation/Logistics:
Hankyu Hanshin Express (USA) Inc.
Carson
CA 90746
DMC Medical Ltd embodies innovation, dedication
and professionalism that makes the support and trust
of you‘the customer’our number one priority.
Since its incorporation in late 1998 DMC Medical has
utilized a team of professionals, all of whom have spent
manyyearsservicingthehealthcareindustryonaglobal
basis. The team at DMC is drawn from a background of
medicaldevicemanufacture,qualityassurance,product
development, customer service and distribution.
All our finished medical devices are manufactured,
tested, sterilized and approved to the highest
international standards. Manufacturing is certified to
ISO 13485:2012, while our product range is tested and
evaluated in accordance with ISO 10993. Sterilization is
by EtO, Gamma Irradiation & Moist Steam, performed
to current ISO standards.
Quality is not an issue at DMC but a fact. Devices are
CE Marked, FDA 510k approved and listed as
appropriate.
Distribution and Customer Service facilities are located
in Carson, California and Shannon, Ireland. These key
locations allow DMC to provide an efficient and cost
effective service to existing and expanding markets.
Our ISO approved sister company DMC Medical Tech.
& Mfg. Co. Ltd., based in DaLang, China, offers us the
opportunity of increased capability and capacity plus
the ability to assist our customers in specific projects.
The last number of years has seen DMC develop a
diverse range of products such as the BPA free NuGen™
syringe, an innovative Eastman Chemical Copolymer,
that’s suitable for both EtO and irradiation sterilization
with improved lipid and chemical resistance suitable for
both the medical device and pharmaceutical markets.
The SureSafe™ syringe, a superbly engineered fully
automatic retractable syringe that addresses the
“accidental needlestick crisis” bringing both safety to
the healthcare worker and cost savings to the hospital.
SupraGel™ & SupraCel™ wound care hydrogels suitable
for direct hospital/acute care centres and OTC sales.
These gels address simple to complex wound care
solutions.
DMCM E D I C A L
DMCM E D I C A L
Automatic Retractable Syringe
Manual Retractable Syringe
SureSafe™ is an exceptionally engineered
safety syringe with automatic retraction that
fully addresses the accidental needlestick
crisis that sees close on 1million healthcare
workers put at risk every year in the U.S. alone.
SureSafe™ is available in 0.5ml, 1ml, 3ml, 5ml
& 10ml with a variety of high quality needle
bores and lengths. Simple single-hand use, the
SureSafe™ is an extremely cost effective syringe
when compared to the competition, with the
added benefit of up to 50% saving on Sharps
containers and disposal charges.
SureSafe™ Safety Syringes 1
Product Code Description
Needle
Gauge
Needle
Length
Units per
box
Total Units
percase
FD-SSFX01L-29 1ml Insulin syringe 29G 1/2” 100 2100
FD-SSFX01T-27 1mlTuberculin 27G 1/2" 100 2100
FD-SSFX01T-25 1mlTuberculin 25G 5/8" 100 2100
FD-SSFX01T-25-01 1mlTuberculin 25G 1" 100 2100
FD-SSFX01-25 1ml syringe 25G 5/8” 100 2100
FD-SSFX01-25-01 1ml syringe 25G 1” 100 2100
Product Code Description
Needle
Gauge
Needle
Length
Units per
box
Total Units
percase
FD-MSSFX005-29 0.5ml syringe 29G 1/2” 100 3000
FD-MSSFX005-29-01 0.5ml Insulin 29G 1/2” 100 3000
FD-MSSFX01-25 1ml syringe 25G 1” 100 3000
FD-MSSFX01-29-01 1ml Insulin 29G 1/2” 100 3000
FD-MSSIC03-25 3ml syringe 25G 1” 100 2400
FD-MSSIC05-22 5ml syringe 22G 1 1/2” 100 1800
FD-MSSIC10-21 10ml syringe 21G 1 1/2” 100 1200
Product Code Description
Needle
Gauge
Needle
Length
Units
perbox
Total Units
percase
FD-SSIC03-25 3ml syringe 25G 5/8" 100 1000
FD-SSIC03-25-01 3ml syringe 25G 1" 100 1000
FD-SSIC03-23 3ml syringe 23G 1" 100 1000
FD-SSIC03-23-01 3ml syringe 23G 1½" 100 1000
FD-SSIC03-22 3ml syringe 22G 1½” 100 1000
FD-SSIC03-22-01 3ml syringe 22G 1” 100 1000
FD-SSIC03-21 3ml syringe 21G 1" 100 1000
FD-SSIC03-21-01 3ml syringe 21G 1½" 100 1000
FD-SSIC05-22 5ml syringe 22G 1½” 100 1000
FD-SSIC05-21 5ml syringe 21G 1½” 100 1000
FD-SSIC10-22 10ml syringe 22G 1½” 100 800
FD-SSIC10-21 10ml syringe 21G 1½” 100 800
FIXEDNEEDLECHANGEABLENEEDLEMANUALRETRACTABLESYRINGE
DMCM E D I C A L
Healthcare workers, both in the U.S. and throughout the world,
continue to suffer “needless” accidental needlestick injuries
because the industry has been slow or reluctant to convert
to a fully automatic retractable needle safety device. There
are numerous needle devices on the market that are safe in
“name only”. Many of these devices require two-handed use
with sliding sheaths, hinged needle covers, manual retraction
and snap-off plungers. One of the major stumbling blocks to
the universal use of a “true” safety syringe has been cost of an
automatic retractable device. The SureSafe™ syringe addresses
the cost, ease of use and complete safety issues.
	
Accidental needlestick injuries cause healthcare workers to
be exposed to over 20 bloodborne pathogens and other
infectious agents including HIV/AIDS, hepatitis B and hepatitis
C. According to the WHO (World Health Organization)
1.3million people die per year from unsafe injection practices.
Despite legislation in the U.S. and the introduction of safe
practices around the world, the uptake of safety syringes has
been sluggish.
	
Accidental needlestick injuries to healthcare workers are
estimated at between 800,000 to 1,000,000 per year in the
United States alone and a similar number reported in Europe.
Reports also indicate that many accidental needlestick injuries
are neither reported nor documented.
	
When using the SureSafe™ automatic retractable syringe, the
needle is automatically and instantly retracted from the patient
into the plunger of the syringe.The syringe is thereby rendered
non-reusable and the contaminated needle is not available to
prick either the medical worker, patient or disposal agent.
History:
The hypodermic syringe was invented in the mid-1840s.
Disposable standard syringes have been manufactured since
the early 1960s.
In 1978, a medical technician at the University of Wisconsin
Hospital contracted hepatitis B from an accidental needlestick
injury. The hospital’s Dr. Dennis Maki and Nurse Rita
McCormick began groundbreaking research that alerted the
medical community to the risk that healthcare workers
face from contracting bloodborne diseases via
contaminated needles.
Their report, published in 1981, Maki and
McCormick determined that many needlestick
injuries occurred during recapping attempts and
subsequently warned medical workers not to recap
needles. Despite the medical community’s realization
that hepatitis B and many other bloodborne pathogens
were frequently spread by accidental needlestick injuries,
it took the deadly spread of HIV/AIDS in the early 1980s to
truly focus attention on the need for needle safety devices
and procedures.
Cost:
Premium safety syringes are priced higher than conventional
(unsafe) syringes. The initial higher cost is very misleading as
to the true final cost when all the factors are totalled. When
comparing the cost of a safety syringe versus a conventional
disposable syringe, what must be factored in is the cost of tests
following an accidental needlestick injury. The cost of needle
disposal must also be included in arriving at the final cost.
A huge forgotten cost is the months of anxiety and worry an
accidental needlestick injury brings with it to the unfortunate
healthcare workers and their families plus the impact on
their personal lifestyles throughout the period of testing and
retesting.
Calculating that cost:
Accidental needlestick injuries occur approximately once
every 6,000 injections given with a conventional disposable
syringe.
SureSafe™ Safety Syringes2
Needle Stick Crisis
DMCM E D I C A L
SureSafe™ Safety Syringes 3
Whenever an accidental needlestick injury occurs, it is
imperative that tests are conducted to determine whether or
not a bloodborne disease has been contracted. It may take
several months before some pathogens can be detected so
follow up testing is necessary. HIV sometimes lies dormant in
the human body for up to three years. Such testing is expensive
with the average cost being in the region of $3,000.
The cost of testing must be taken into account mathematically
in order to arrive at the true cost of a syringe. For each
conventional syringe that is used for an injection, the
approximate testing cost can be calculated by dividing $3,000
by 6,000. So each injection with a conventional syringe carries
a hidden cost (the cost for disease testing of needlestick injury
victims) of approx. $0.50. However, SureSafe™ syringes virtually
eliminates any risk from accidental needle stick injury, so for
each SureSafe™ syringe that is used for an injection the testing
cost is essentially zero.
Disposal costs must also be taken into account. This
includes the cost of the sharps disposal box plus the cost
of transportation to the incineration site and the cost of
incineration. For a conventional disposable syringe, the
disposal cost is approximately $0.18 each. Any sharps disposal
box will hold at least twice as many activated SureSafe™
syringes as conventional syringes.
The true cost of a syringe can be calculated as follows:
Purchase price + testing cost + disposal cost = actual cost
Even if the purchase price of a SureSafe™ syringe were four
times as much as the purchase price of a conventional syringe,
the actual cost of the conventional syringe would still be
more expensive. Assuming a purchase price of $0.08 for a
conventional syringe, the actual cost is calculated below:
$0.08 + $0.50 + $0.18 = $0.76
Assuming a purchase price of $0.30 for a SureSafe™ syringe, the
actual cost is:
$0.30 + $0.00 + $0.09 = $0.39 - Automatic Version
$0.16 + $0.00 + $0.09 = $0.25 - Manual Version
An average 250 bed hospital spends between $80,000 to
$100,000 per year on the purchase of Sharps containers alone.
The overall saving for such a hospital purchasing at least 50%
less Sharps containers and the reduced tonnage of infectious
waste disposal represents an overall saving of at least $150,000,
not to mention the elimination of accidental needlestick
injuries and the protection of its healthcare workers.
When these costs are taken into account, it is actually more
cost effective to use a SureSafe™ safety syringe than to use
a conventional syringe or one of the many so-called semi
“safety” syringes that do not effectively prevent reuse, are not
single handed activated and safety in “name only”. SureSafe™
not only offers superb protection but also makes excellent
economic sense.
DMCM E D I C A L
DMC Medical has developed a comprehensive range of
Color Coded, Latex Free Polycarbonate Syringes available in
94 variations. Crystal clear barrels with a secure luer lock tip
are available in 1ml, 3ml, 6ml, 10ml, 20ml & 30ml. DMC also
offers a pre-printed custom syringe range in similar sizes and
colors. Supplied bulk non-sterile. Our Polycarbonate Syringes
are FDA 510k approved and manufactured in accordance with
ISO 13485.
Product Description Units perbox Boxes percarton Total Units
1ml Polycarbonate Syringe - 7 Colors Available + Printed Option 100 12 1200
3ml Polycarbonate Syringe - 7 Colors Available + Printed Option 100 12 1200
6ml Polycarbonate Syringe - 7 Colors Available + Printed Option 100 12 1200
10ml Polycarbonate Syringe - 7 Colors Available + Printed Option 100 8 800
20ml Polycarbonate Syringe - 7 Colors Available + Printed Option 50 12 600
30ml Polycarbonate Syringe - 7 Colors Available + Printed Option 50 12 600
Polycarbonate
Syringes
3ml Nitro
10ml Heparin
10ml Contrast
10ml Nitro
10ml Lidocane
10ml Saline
20ml Heparin
20ml Saline
Available Colors for Pre-Printed Syringes
1ml 3ml 6ml 10ml 20ml 30ml
FD-1017NS FD-1021NS FD-1025NS FD-1026NS FD-1031NS FD-1035NS
FD-1018NS FD-1022NS FD-1069NS FD-1027NS FD-1032NS FD-1036NS
FD-1110NS FD-1096NS FD-1100NS FD-1071NS FD-1103NS FD-1073NS
FD-1020NS FD-1024NS FD-1070NS FD-1029NS FD-1034NS FD-1106NS
FD-1019NS FD-1023NS FD-1099NS FD-1028NS FD-1033NS FD-1107NS
FD-1094NS FD-1097NS FD-1101NS FD-1030NS FD-1104NS FD-1108NS
FD-1095NS FD-1098NS FD-1102NS FD-1072NS FD-1105NS FD-1109NS
Polycarbonate Syringes4
DMCM E D I C A L
DMC Medical has developed a new and exciting range of
copolyester syringes with advanced features. This material offers
many advantages such as BPA free (Bisphenol A) improved
chemical & lipid resistance, glass like clarity, toughness and
suitable for both EtO & radiation sterilization. Available in luer
lock1ml,3ml,6ml,10ml,20ml&30mlwithsevendifferentplunger
color variations. Supplied bulk non-sterile the NuGen™ syringe
is FDA 510K approved and manufactured in accordance with
ISO 13485.
Product Description Units perbox Boxespercarton Total Units
1ml NuGen™ EastmanTritan ™ Copolyester Syringes - 7 Colors Available + Printed Option 100 12 1200
3ml NuGen™ EastmanTritan ™ Copolyester Syringes - 7 Colors Available + Printed Option 100 12 1200
6ml NuGen™ EastmanTritan ™ Copolyester Syringes - 7 Colors Available + Printed Option 100 12 1200
10ml NuGen™ EastmanTritan ™ Copolyester Syringes - 7 Colors Available + Printed Option 100 8 800
20ml NuGen™ EastmanTritan ™ Copolyester Syringes - 7 Colors Available + Printed Option 50 12 600
30ml NuGen™ EastmanTritan ™ Copolyester Syringes - 7 Colors Available + Printed Option 50 12 600
NuGen Eastman Tritan
Copolyester Syringes
™™
1ml 3ml 6ml 10ml 20ml 30ml
FD-1159NS FD-1178NS FD-1183NS FD-1188NS FD-1193NS FD-1198NS
FD-1172NS FD-1167NS FD-1161NS FD-1189NS FD-1170NS FD-1199NS
FD-1173NS FD-1179NS FD-1184NS FD-1165NS FD-1194NS FD-1171NS
FD-1174NS FD-1180NS FD-1185NS FD-1162NS FD-1195NS FD-1200NS
FD-1175NS FD-1160NS FD-1186NS FD-1190NS FD-1196NS FD-1201NS
FD-1176NS FD-1181NS FD-1168NS FD-1191NS FD-1163NS FD-1202NS
FD-1177NS FD-1182NS FD-1187NS FD-1192NS FD-1197NS FD-1164NS
NuGen™ Eastman Tritan ™ Copolyester Syringes 5
DMCM E D I C A L
Bevelled & Blunt (VIC & BIC)
Manufactured in a blunt and bevelled format, these cannulae may
be used in conjunction with the Saphenous Vein Distention system.
The cannulae are supplied both sterile and bulk non-sterile.
Product Code Description Units perbox Boxes percarton Total Units
FD-1006 VIC - Sterile - BevelledVein Irrigation Cannula 25 21 525
FD-1006NS VIC - Non Sterile - BevelledVein Irrigation Cannula 100 16 1600
FD-1007 BIC - Sterile - BluntVein Irrigation Cannula 25 21 525
FD-1007NS BIC - Non Sterile - BluntVein Irrigation Cannula 100 16 1600
FD-1006 FD-1007
Vein Irrigation Cannulae
Vein Irrigation Cannulae Bevelled & Blunt6
DMCM E D I C A L
Product Code Description Units perbox Boxes percarton Total Units
FD-1148 Add-A-Grip 2 part accessory -Thumb & Finger Grips 250 10 2500
FD-1152 Add-A-Grip 3 part accessory -Thumb & Finger Grips/Syringe 100 12 1200
The Add-A-Grip has been developed by DMC Medical to fit its
standard 10ml syringe, giving the operator greater control and
increased ability to push during the infusion procedure. Its simple
“snap-on” set up takes just a few seconds to assemble, ready for
use. It is supplied in 2 formats, format 1, which is the Thumb &
Finger Grips only and format 2, where the Thumb & Finger Grips
come fully assembled on the Syringe. Both formats are supplied
bulk non-sterile. Format 1 is packaged in lots of 250 pieces in a
double PE bag and format 2 in a single pouch.
Add-A-Grip
Add-A-Grip 7
Available with any
10ml syringe, either
printed or unprinted
in Polycarbonate or
NuGen™ formats
DMCM E D I C A L
A range of high quality connectors used to join tubing lines
in both anaesthesiology and cardiovascular procedures. Supplied
bulk non-sterile in both clear and blue tinted formats.
Polycarbonate
Connectors
Polycarbonate Connectors8
Product Code Description Units perbox Boxes percarton Total Units
FD-1009NS Non Sterile 3/8 x 3/8 x 3/8“Y”Connector - Clear 200 n/a 200
FD-1010NS Non Sterile 1/2 x 1/2 Straight Connector - Clear 200 n/a 200
FD-1011NS Non Sterile 3/8 x 3/8 Straight Connector - Clear 400 n/a 400
FD-1012NS Non Sterile 3/8 x 3/8 x 3/8“Y”Connector -Tint 200 n/a 200
FD-1013NS Non Sterile 1/2 x 1/2 Straight Connector -Tint 200 n/a 200
FD-1014NS Non Sterile 3/8 x 3/8 Straight Connector -Tint 400 n/a 400
DMCM E D I C A L
(SVDS)
The SVDS limits the pressure that can be applied to the
saphenous vein during the harvesting procedure. Unique
latex free pressure limiting balloon prevents complications
associated with overdistension, such as endothelial damage,
thrombosis, sub-endothelial hyperplasia and accelerated
lipid uptake. After harvesting, the vein is used as a graft in
bypassing blockages in the coronary arteries. Manufactured in
accordance with ISO13485 the device is FDA 510k approved.
Supplied sterile in two color coded pressure limiting sizes,
200mm Hg & 300mm Hg.
Saphenous Vein
Distention System
Saphenous Vein Distention System 9
Product Code Description Units perbox Boxes percarton Total Units
FD-1003 SaphenousVein Distension System - 200mm Hg - Sterile 5 3 15
FD-1004 SaphenousVein Distension System - 300mm Hg - Sterile 5 3 15
DMCM E D I C A L
The CIPA is manufactured in an adult size and protects the
heart from re-warming during the bypass procedure. The
pad is intended to insulate the myocardium from the warmer
descending thoracic aorta and surrounding pericardial tissues. It
alsoensuresagainstdamagetothephrenicnerve.Thepadisthin
and pliable and conforms well to the shape of the heart and may
be easily cut if required. Secure tape attached for easy removal.
The product is supplied both sterile and bulk non-sterile.
Cardiac Insulation Pad
(CIPA)
Cardiac Insulation Pad10
Product Code Description Units perbox Boxes percarton Total Units
FD-1001 Sterile Cardiac Insulation Pad - Adult 10 8 80
FD-1001NS Non-Sterile Cardiac Insulation Pad - Adult 45 4 180
DMCM E D I C A L
Thisheart positioningdevice is a polyester net used during open-
heart surgery. Greatly assists in positioning the heart at optimum
levels within the chest cavity. It allows access to the posterior side
of the heart for grafting. Supplied both sterile and bulk non-sterile.
HeartNet
Heart Positioning Device
™
HeartNet™ 11
Product Code Description Unitsperbox Boxes percarton Total Units
FD-1015 Sterile HeartNet™ - Heart Positioning Device 10 8 80
FD-1015NS Non-Sterile HeartNet™ - Heart Positioning Device 20 4 80
DMCM E D I C A L
SupraGel™ is a cross-linked sterile amorphous hydrogel
containing complex carbohydrates, CMC, propylene glycol and
ultra pure water. Dependent on wound conditions, SupraGel™ has
the ability to rehydrate dry necrotic tissue thus providing rapid
wound debridement in addition to absorbing slough and excess
exudates.Duetoitsfullycross-linkednature,nomacerationoccurs
and SupraGel™ maintains its physical integrity throughout its use.
wound care hydrogel
TM
SupraGel™ Wound Care Hydrogel12
Suitable for
Cuts
Grazes
Rashes
ExudingWounds
Burns 1st & 2nd degree
CavityWounds
Leg Ulcers
Product Code Description Units perbox Boxes percarton Total Units
FD-1140 SupraGel™ Amorphous Sterile Hydrogel - 25g tube 20 12 240
DMCM E D I C A L
SupraCel™ sheet dressing is a cross-linked sterile hydrogel containing a solid polymer matrix
with propylene glycol. Dependent on wound conditions, SupraCel™ has the ability to absorb
wound exudates while maintaining an excellent moisture balance. Due to its fully cross-linked
nature there will no maceration of the skin surrounding the wound. SupraCel™ maintains its
physical integrity throughout its use.
SupraCel™ Wound Care Hydrogel 13
Suitable for
Burns 1st & 2nd degree
Sunburn
Blisters
Rashes
Grazes
Leg Ulcers
Post Operative Surgical
Wounds
Pressure Ulcers
Product Code Description Units perbox Boxes percarton Total Units
FD-1143 SupraCel™ Flat Sheet Sterile Hydrogel - 2”x 2”(50mm x 50mm) 100 4 400
FD-1141 SupraCel™ Flat Sheet Sterile Hydrogel - 4”x 4”(100mm x 100mm) 100 2 200
FD-1151 SupraCel™ Flat Sheet Sterile Hydrogel - 8”x 3”(200mm x 75mm) 50 2 100
FD-1204 SupraCel™ Flat Sheet Sterile Hydrogel – 8”x 8”(200mm x 200mm) 50 2 100
DMC Medical Limited
Corporate Headquarters
Unit 2, Abbey House
Shannon
County Clare
Ireland
info@dmcmedical.net
www.dmcmedical.net
Telephone:	
Ireland: 	 +353 61 718900
U.S.A.:	 +1 949 916 7253
Fax:	
Ireland:	 +353 61 718944
U.S.A.:	 +1 949 916 7254
DMC Medical Tech. & Mfg. Co. Ltd
DaLang Town,
Dongguan City
Guangdong Province
China
info@dmcmedical.net
www.dmcmedical.net
w w w . d m c m e d i c a l . n e t
DMCM E D I C A L

More Related Content

Similar to DMC Brochure 2016

Uniqsafe retractable safety syringe
Uniqsafe retractable safety syringeUniqsafe retractable safety syringe
Uniqsafe retractable safety syringeMichael Wu
 
Resource Pharmaceuticals, Vadodara, Surgical Equipment
 Resource Pharmaceuticals, Vadodara, Surgical Equipment Resource Pharmaceuticals, Vadodara, Surgical Equipment
Resource Pharmaceuticals, Vadodara, Surgical EquipmentIndiaMART InterMESH Limited
 
Roll of gloves
Roll of glovesRoll of gloves
Roll of glovesjindalcs
 
Work Related Infections
Work   Related InfectionsWork   Related Infections
Work Related Infectionsmeeqat453
 
Needlestick Injuries: A guide for safe needle handling
Needlestick Injuries: A guide for safe needle handlingNeedlestick Injuries: A guide for safe needle handling
Needlestick Injuries: A guide for safe needle handlingMarketLab Inc.
 
Zapper sales presentation
Zapper sales presentationZapper sales presentation
Zapper sales presentationCisco Martinez
 
Zapper sales presentation w my pic in it
Zapper sales presentation w my pic in itZapper sales presentation w my pic in it
Zapper sales presentation w my pic in itCisco Martinez
 
Why is an 'unnecessary' injection unsafe?
Why is an 'unnecessary' injection unsafe?Why is an 'unnecessary' injection unsafe?
Why is an 'unnecessary' injection unsafe?Aadhira Laghari
 
Medflybloodsupplies.pptx
Medflybloodsupplies.pptxMedflybloodsupplies.pptx
Medflybloodsupplies.pptxMedFly
 
Sharps Technology Investor Presentation June 2022
Sharps Technology Investor Presentation June 2022Sharps Technology Investor Presentation June 2022
Sharps Technology Investor Presentation June 2022RedChip Companies, Inc.
 
Exposure control
Exposure controlExposure control
Exposure controlcallahand
 
Blood lancet manufacturers
Blood lancet manufacturersBlood lancet manufacturers
Blood lancet manufacturersjindalmedical
 
Prevent needle stick injuries (Mr.Ram.S)
Prevent needle stick injuries (Mr.Ram.S)Prevent needle stick injuries (Mr.Ram.S)
Prevent needle stick injuries (Mr.Ram.S)RAMS111
 
2 exposure control barriers for patient and clinician
2 exposure control barriers for patient and clinician2 exposure control barriers for patient and clinician
2 exposure control barriers for patient and cliniciandvernetti
 

Similar to DMC Brochure 2016 (20)

NeedleStick-p
NeedleStick-pNeedleStick-p
NeedleStick-p
 
Uniqsafe retractable safety syringe
Uniqsafe retractable safety syringeUniqsafe retractable safety syringe
Uniqsafe retractable safety syringe
 
U-Cann Article to send
U-Cann Article to sendU-Cann Article to send
U-Cann Article to send
 
Resource Pharmaceuticals, Vadodara, Surgical Equipment
 Resource Pharmaceuticals, Vadodara, Surgical Equipment Resource Pharmaceuticals, Vadodara, Surgical Equipment
Resource Pharmaceuticals, Vadodara, Surgical Equipment
 
Roll of gloves
Roll of glovesRoll of gloves
Roll of gloves
 
Flyer_WFA
Flyer_WFAFlyer_WFA
Flyer_WFA
 
NSI.pptx
NSI.pptxNSI.pptx
NSI.pptx
 
SECURINJECT.pdf
SECURINJECT.pdfSECURINJECT.pdf
SECURINJECT.pdf
 
Work Related Infections
Work   Related InfectionsWork   Related Infections
Work Related Infections
 
Needlestick Injuries: A guide for safe needle handling
Needlestick Injuries: A guide for safe needle handlingNeedlestick Injuries: A guide for safe needle handling
Needlestick Injuries: A guide for safe needle handling
 
Zapper sales presentation
Zapper sales presentationZapper sales presentation
Zapper sales presentation
 
Zapper sales presentation w my pic in it
Zapper sales presentation w my pic in itZapper sales presentation w my pic in it
Zapper sales presentation w my pic in it
 
Why is an 'unnecessary' injection unsafe?
Why is an 'unnecessary' injection unsafe?Why is an 'unnecessary' injection unsafe?
Why is an 'unnecessary' injection unsafe?
 
Medflybloodsupplies.pptx
Medflybloodsupplies.pptxMedflybloodsupplies.pptx
Medflybloodsupplies.pptx
 
Sharps Technology Investor Presentation June 2022
Sharps Technology Investor Presentation June 2022Sharps Technology Investor Presentation June 2022
Sharps Technology Investor Presentation June 2022
 
Exposure control
Exposure controlExposure control
Exposure control
 
Blood lancet manufacturers
Blood lancet manufacturersBlood lancet manufacturers
Blood lancet manufacturers
 
educational
educationaleducational
educational
 
Prevent needle stick injuries (Mr.Ram.S)
Prevent needle stick injuries (Mr.Ram.S)Prevent needle stick injuries (Mr.Ram.S)
Prevent needle stick injuries (Mr.Ram.S)
 
2 exposure control barriers for patient and clinician
2 exposure control barriers for patient and clinician2 exposure control barriers for patient and clinician
2 exposure control barriers for patient and clinician
 

DMC Brochure 2016

  • 1. w w w . d m c m e d i c a l . n e t DMCM E D I C A L
  • 2. Bryan Wixted CEO DMC Medical Ltd. Ireland Carolyne Deer Administration Manager, Ireland Mike Clancy Product Development Manager, Ireland Bill Zhang Quality Engineering Manager, China Andy Song CEO DMC Medical Tech. & Mfg. Co. Ltd. China Charmaine Henderson Regulatory Director, U.S.A. Julie Torres Customer Service, U.S.A. Transportation/Logistics: Hankyu Hanshin Express (USA) Inc. Carson CA 90746 DMC Medical Ltd embodies innovation, dedication and professionalism that makes the support and trust of you‘the customer’our number one priority. Since its incorporation in late 1998 DMC Medical has utilized a team of professionals, all of whom have spent manyyearsservicingthehealthcareindustryonaglobal basis. The team at DMC is drawn from a background of medicaldevicemanufacture,qualityassurance,product development, customer service and distribution. All our finished medical devices are manufactured, tested, sterilized and approved to the highest international standards. Manufacturing is certified to ISO 13485:2012, while our product range is tested and evaluated in accordance with ISO 10993. Sterilization is by EtO, Gamma Irradiation & Moist Steam, performed to current ISO standards. Quality is not an issue at DMC but a fact. Devices are CE Marked, FDA 510k approved and listed as appropriate. Distribution and Customer Service facilities are located in Carson, California and Shannon, Ireland. These key locations allow DMC to provide an efficient and cost effective service to existing and expanding markets. Our ISO approved sister company DMC Medical Tech. & Mfg. Co. Ltd., based in DaLang, China, offers us the opportunity of increased capability and capacity plus the ability to assist our customers in specific projects. The last number of years has seen DMC develop a diverse range of products such as the BPA free NuGen™ syringe, an innovative Eastman Chemical Copolymer, that’s suitable for both EtO and irradiation sterilization with improved lipid and chemical resistance suitable for both the medical device and pharmaceutical markets. The SureSafe™ syringe, a superbly engineered fully automatic retractable syringe that addresses the “accidental needlestick crisis” bringing both safety to the healthcare worker and cost savings to the hospital. SupraGel™ & SupraCel™ wound care hydrogels suitable for direct hospital/acute care centres and OTC sales. These gels address simple to complex wound care solutions. DMCM E D I C A L
  • 3. DMCM E D I C A L Automatic Retractable Syringe Manual Retractable Syringe SureSafe™ is an exceptionally engineered safety syringe with automatic retraction that fully addresses the accidental needlestick crisis that sees close on 1million healthcare workers put at risk every year in the U.S. alone. SureSafe™ is available in 0.5ml, 1ml, 3ml, 5ml & 10ml with a variety of high quality needle bores and lengths. Simple single-hand use, the SureSafe™ is an extremely cost effective syringe when compared to the competition, with the added benefit of up to 50% saving on Sharps containers and disposal charges. SureSafe™ Safety Syringes 1 Product Code Description Needle Gauge Needle Length Units per box Total Units percase FD-SSFX01L-29 1ml Insulin syringe 29G 1/2” 100 2100 FD-SSFX01T-27 1mlTuberculin 27G 1/2" 100 2100 FD-SSFX01T-25 1mlTuberculin 25G 5/8" 100 2100 FD-SSFX01T-25-01 1mlTuberculin 25G 1" 100 2100 FD-SSFX01-25 1ml syringe 25G 5/8” 100 2100 FD-SSFX01-25-01 1ml syringe 25G 1” 100 2100 Product Code Description Needle Gauge Needle Length Units per box Total Units percase FD-MSSFX005-29 0.5ml syringe 29G 1/2” 100 3000 FD-MSSFX005-29-01 0.5ml Insulin 29G 1/2” 100 3000 FD-MSSFX01-25 1ml syringe 25G 1” 100 3000 FD-MSSFX01-29-01 1ml Insulin 29G 1/2” 100 3000 FD-MSSIC03-25 3ml syringe 25G 1” 100 2400 FD-MSSIC05-22 5ml syringe 22G 1 1/2” 100 1800 FD-MSSIC10-21 10ml syringe 21G 1 1/2” 100 1200 Product Code Description Needle Gauge Needle Length Units perbox Total Units percase FD-SSIC03-25 3ml syringe 25G 5/8" 100 1000 FD-SSIC03-25-01 3ml syringe 25G 1" 100 1000 FD-SSIC03-23 3ml syringe 23G 1" 100 1000 FD-SSIC03-23-01 3ml syringe 23G 1½" 100 1000 FD-SSIC03-22 3ml syringe 22G 1½” 100 1000 FD-SSIC03-22-01 3ml syringe 22G 1” 100 1000 FD-SSIC03-21 3ml syringe 21G 1" 100 1000 FD-SSIC03-21-01 3ml syringe 21G 1½" 100 1000 FD-SSIC05-22 5ml syringe 22G 1½” 100 1000 FD-SSIC05-21 5ml syringe 21G 1½” 100 1000 FD-SSIC10-22 10ml syringe 22G 1½” 100 800 FD-SSIC10-21 10ml syringe 21G 1½” 100 800 FIXEDNEEDLECHANGEABLENEEDLEMANUALRETRACTABLESYRINGE
  • 4. DMCM E D I C A L Healthcare workers, both in the U.S. and throughout the world, continue to suffer “needless” accidental needlestick injuries because the industry has been slow or reluctant to convert to a fully automatic retractable needle safety device. There are numerous needle devices on the market that are safe in “name only”. Many of these devices require two-handed use with sliding sheaths, hinged needle covers, manual retraction and snap-off plungers. One of the major stumbling blocks to the universal use of a “true” safety syringe has been cost of an automatic retractable device. The SureSafe™ syringe addresses the cost, ease of use and complete safety issues. Accidental needlestick injuries cause healthcare workers to be exposed to over 20 bloodborne pathogens and other infectious agents including HIV/AIDS, hepatitis B and hepatitis C. According to the WHO (World Health Organization) 1.3million people die per year from unsafe injection practices. Despite legislation in the U.S. and the introduction of safe practices around the world, the uptake of safety syringes has been sluggish. Accidental needlestick injuries to healthcare workers are estimated at between 800,000 to 1,000,000 per year in the United States alone and a similar number reported in Europe. Reports also indicate that many accidental needlestick injuries are neither reported nor documented. When using the SureSafe™ automatic retractable syringe, the needle is automatically and instantly retracted from the patient into the plunger of the syringe.The syringe is thereby rendered non-reusable and the contaminated needle is not available to prick either the medical worker, patient or disposal agent. History: The hypodermic syringe was invented in the mid-1840s. Disposable standard syringes have been manufactured since the early 1960s. In 1978, a medical technician at the University of Wisconsin Hospital contracted hepatitis B from an accidental needlestick injury. The hospital’s Dr. Dennis Maki and Nurse Rita McCormick began groundbreaking research that alerted the medical community to the risk that healthcare workers face from contracting bloodborne diseases via contaminated needles. Their report, published in 1981, Maki and McCormick determined that many needlestick injuries occurred during recapping attempts and subsequently warned medical workers not to recap needles. Despite the medical community’s realization that hepatitis B and many other bloodborne pathogens were frequently spread by accidental needlestick injuries, it took the deadly spread of HIV/AIDS in the early 1980s to truly focus attention on the need for needle safety devices and procedures. Cost: Premium safety syringes are priced higher than conventional (unsafe) syringes. The initial higher cost is very misleading as to the true final cost when all the factors are totalled. When comparing the cost of a safety syringe versus a conventional disposable syringe, what must be factored in is the cost of tests following an accidental needlestick injury. The cost of needle disposal must also be included in arriving at the final cost. A huge forgotten cost is the months of anxiety and worry an accidental needlestick injury brings with it to the unfortunate healthcare workers and their families plus the impact on their personal lifestyles throughout the period of testing and retesting. Calculating that cost: Accidental needlestick injuries occur approximately once every 6,000 injections given with a conventional disposable syringe. SureSafe™ Safety Syringes2 Needle Stick Crisis
  • 5. DMCM E D I C A L SureSafe™ Safety Syringes 3 Whenever an accidental needlestick injury occurs, it is imperative that tests are conducted to determine whether or not a bloodborne disease has been contracted. It may take several months before some pathogens can be detected so follow up testing is necessary. HIV sometimes lies dormant in the human body for up to three years. Such testing is expensive with the average cost being in the region of $3,000. The cost of testing must be taken into account mathematically in order to arrive at the true cost of a syringe. For each conventional syringe that is used for an injection, the approximate testing cost can be calculated by dividing $3,000 by 6,000. So each injection with a conventional syringe carries a hidden cost (the cost for disease testing of needlestick injury victims) of approx. $0.50. However, SureSafe™ syringes virtually eliminates any risk from accidental needle stick injury, so for each SureSafe™ syringe that is used for an injection the testing cost is essentially zero. Disposal costs must also be taken into account. This includes the cost of the sharps disposal box plus the cost of transportation to the incineration site and the cost of incineration. For a conventional disposable syringe, the disposal cost is approximately $0.18 each. Any sharps disposal box will hold at least twice as many activated SureSafe™ syringes as conventional syringes. The true cost of a syringe can be calculated as follows: Purchase price + testing cost + disposal cost = actual cost Even if the purchase price of a SureSafe™ syringe were four times as much as the purchase price of a conventional syringe, the actual cost of the conventional syringe would still be more expensive. Assuming a purchase price of $0.08 for a conventional syringe, the actual cost is calculated below: $0.08 + $0.50 + $0.18 = $0.76 Assuming a purchase price of $0.30 for a SureSafe™ syringe, the actual cost is: $0.30 + $0.00 + $0.09 = $0.39 - Automatic Version $0.16 + $0.00 + $0.09 = $0.25 - Manual Version An average 250 bed hospital spends between $80,000 to $100,000 per year on the purchase of Sharps containers alone. The overall saving for such a hospital purchasing at least 50% less Sharps containers and the reduced tonnage of infectious waste disposal represents an overall saving of at least $150,000, not to mention the elimination of accidental needlestick injuries and the protection of its healthcare workers. When these costs are taken into account, it is actually more cost effective to use a SureSafe™ safety syringe than to use a conventional syringe or one of the many so-called semi “safety” syringes that do not effectively prevent reuse, are not single handed activated and safety in “name only”. SureSafe™ not only offers superb protection but also makes excellent economic sense.
  • 6. DMCM E D I C A L DMC Medical has developed a comprehensive range of Color Coded, Latex Free Polycarbonate Syringes available in 94 variations. Crystal clear barrels with a secure luer lock tip are available in 1ml, 3ml, 6ml, 10ml, 20ml & 30ml. DMC also offers a pre-printed custom syringe range in similar sizes and colors. Supplied bulk non-sterile. Our Polycarbonate Syringes are FDA 510k approved and manufactured in accordance with ISO 13485. Product Description Units perbox Boxes percarton Total Units 1ml Polycarbonate Syringe - 7 Colors Available + Printed Option 100 12 1200 3ml Polycarbonate Syringe - 7 Colors Available + Printed Option 100 12 1200 6ml Polycarbonate Syringe - 7 Colors Available + Printed Option 100 12 1200 10ml Polycarbonate Syringe - 7 Colors Available + Printed Option 100 8 800 20ml Polycarbonate Syringe - 7 Colors Available + Printed Option 50 12 600 30ml Polycarbonate Syringe - 7 Colors Available + Printed Option 50 12 600 Polycarbonate Syringes 3ml Nitro 10ml Heparin 10ml Contrast 10ml Nitro 10ml Lidocane 10ml Saline 20ml Heparin 20ml Saline Available Colors for Pre-Printed Syringes 1ml 3ml 6ml 10ml 20ml 30ml FD-1017NS FD-1021NS FD-1025NS FD-1026NS FD-1031NS FD-1035NS FD-1018NS FD-1022NS FD-1069NS FD-1027NS FD-1032NS FD-1036NS FD-1110NS FD-1096NS FD-1100NS FD-1071NS FD-1103NS FD-1073NS FD-1020NS FD-1024NS FD-1070NS FD-1029NS FD-1034NS FD-1106NS FD-1019NS FD-1023NS FD-1099NS FD-1028NS FD-1033NS FD-1107NS FD-1094NS FD-1097NS FD-1101NS FD-1030NS FD-1104NS FD-1108NS FD-1095NS FD-1098NS FD-1102NS FD-1072NS FD-1105NS FD-1109NS Polycarbonate Syringes4
  • 7. DMCM E D I C A L DMC Medical has developed a new and exciting range of copolyester syringes with advanced features. This material offers many advantages such as BPA free (Bisphenol A) improved chemical & lipid resistance, glass like clarity, toughness and suitable for both EtO & radiation sterilization. Available in luer lock1ml,3ml,6ml,10ml,20ml&30mlwithsevendifferentplunger color variations. Supplied bulk non-sterile the NuGen™ syringe is FDA 510K approved and manufactured in accordance with ISO 13485. Product Description Units perbox Boxespercarton Total Units 1ml NuGen™ EastmanTritan ™ Copolyester Syringes - 7 Colors Available + Printed Option 100 12 1200 3ml NuGen™ EastmanTritan ™ Copolyester Syringes - 7 Colors Available + Printed Option 100 12 1200 6ml NuGen™ EastmanTritan ™ Copolyester Syringes - 7 Colors Available + Printed Option 100 12 1200 10ml NuGen™ EastmanTritan ™ Copolyester Syringes - 7 Colors Available + Printed Option 100 8 800 20ml NuGen™ EastmanTritan ™ Copolyester Syringes - 7 Colors Available + Printed Option 50 12 600 30ml NuGen™ EastmanTritan ™ Copolyester Syringes - 7 Colors Available + Printed Option 50 12 600 NuGen Eastman Tritan Copolyester Syringes ™™ 1ml 3ml 6ml 10ml 20ml 30ml FD-1159NS FD-1178NS FD-1183NS FD-1188NS FD-1193NS FD-1198NS FD-1172NS FD-1167NS FD-1161NS FD-1189NS FD-1170NS FD-1199NS FD-1173NS FD-1179NS FD-1184NS FD-1165NS FD-1194NS FD-1171NS FD-1174NS FD-1180NS FD-1185NS FD-1162NS FD-1195NS FD-1200NS FD-1175NS FD-1160NS FD-1186NS FD-1190NS FD-1196NS FD-1201NS FD-1176NS FD-1181NS FD-1168NS FD-1191NS FD-1163NS FD-1202NS FD-1177NS FD-1182NS FD-1187NS FD-1192NS FD-1197NS FD-1164NS NuGen™ Eastman Tritan ™ Copolyester Syringes 5
  • 8. DMCM E D I C A L Bevelled & Blunt (VIC & BIC) Manufactured in a blunt and bevelled format, these cannulae may be used in conjunction with the Saphenous Vein Distention system. The cannulae are supplied both sterile and bulk non-sterile. Product Code Description Units perbox Boxes percarton Total Units FD-1006 VIC - Sterile - BevelledVein Irrigation Cannula 25 21 525 FD-1006NS VIC - Non Sterile - BevelledVein Irrigation Cannula 100 16 1600 FD-1007 BIC - Sterile - BluntVein Irrigation Cannula 25 21 525 FD-1007NS BIC - Non Sterile - BluntVein Irrigation Cannula 100 16 1600 FD-1006 FD-1007 Vein Irrigation Cannulae Vein Irrigation Cannulae Bevelled & Blunt6
  • 9. DMCM E D I C A L Product Code Description Units perbox Boxes percarton Total Units FD-1148 Add-A-Grip 2 part accessory -Thumb & Finger Grips 250 10 2500 FD-1152 Add-A-Grip 3 part accessory -Thumb & Finger Grips/Syringe 100 12 1200 The Add-A-Grip has been developed by DMC Medical to fit its standard 10ml syringe, giving the operator greater control and increased ability to push during the infusion procedure. Its simple “snap-on” set up takes just a few seconds to assemble, ready for use. It is supplied in 2 formats, format 1, which is the Thumb & Finger Grips only and format 2, where the Thumb & Finger Grips come fully assembled on the Syringe. Both formats are supplied bulk non-sterile. Format 1 is packaged in lots of 250 pieces in a double PE bag and format 2 in a single pouch. Add-A-Grip Add-A-Grip 7 Available with any 10ml syringe, either printed or unprinted in Polycarbonate or NuGen™ formats
  • 10. DMCM E D I C A L A range of high quality connectors used to join tubing lines in both anaesthesiology and cardiovascular procedures. Supplied bulk non-sterile in both clear and blue tinted formats. Polycarbonate Connectors Polycarbonate Connectors8 Product Code Description Units perbox Boxes percarton Total Units FD-1009NS Non Sterile 3/8 x 3/8 x 3/8“Y”Connector - Clear 200 n/a 200 FD-1010NS Non Sterile 1/2 x 1/2 Straight Connector - Clear 200 n/a 200 FD-1011NS Non Sterile 3/8 x 3/8 Straight Connector - Clear 400 n/a 400 FD-1012NS Non Sterile 3/8 x 3/8 x 3/8“Y”Connector -Tint 200 n/a 200 FD-1013NS Non Sterile 1/2 x 1/2 Straight Connector -Tint 200 n/a 200 FD-1014NS Non Sterile 3/8 x 3/8 Straight Connector -Tint 400 n/a 400
  • 11. DMCM E D I C A L (SVDS) The SVDS limits the pressure that can be applied to the saphenous vein during the harvesting procedure. Unique latex free pressure limiting balloon prevents complications associated with overdistension, such as endothelial damage, thrombosis, sub-endothelial hyperplasia and accelerated lipid uptake. After harvesting, the vein is used as a graft in bypassing blockages in the coronary arteries. Manufactured in accordance with ISO13485 the device is FDA 510k approved. Supplied sterile in two color coded pressure limiting sizes, 200mm Hg & 300mm Hg. Saphenous Vein Distention System Saphenous Vein Distention System 9 Product Code Description Units perbox Boxes percarton Total Units FD-1003 SaphenousVein Distension System - 200mm Hg - Sterile 5 3 15 FD-1004 SaphenousVein Distension System - 300mm Hg - Sterile 5 3 15
  • 12. DMCM E D I C A L The CIPA is manufactured in an adult size and protects the heart from re-warming during the bypass procedure. The pad is intended to insulate the myocardium from the warmer descending thoracic aorta and surrounding pericardial tissues. It alsoensuresagainstdamagetothephrenicnerve.Thepadisthin and pliable and conforms well to the shape of the heart and may be easily cut if required. Secure tape attached for easy removal. The product is supplied both sterile and bulk non-sterile. Cardiac Insulation Pad (CIPA) Cardiac Insulation Pad10 Product Code Description Units perbox Boxes percarton Total Units FD-1001 Sterile Cardiac Insulation Pad - Adult 10 8 80 FD-1001NS Non-Sterile Cardiac Insulation Pad - Adult 45 4 180
  • 13. DMCM E D I C A L Thisheart positioningdevice is a polyester net used during open- heart surgery. Greatly assists in positioning the heart at optimum levels within the chest cavity. It allows access to the posterior side of the heart for grafting. Supplied both sterile and bulk non-sterile. HeartNet Heart Positioning Device ™ HeartNet™ 11 Product Code Description Unitsperbox Boxes percarton Total Units FD-1015 Sterile HeartNet™ - Heart Positioning Device 10 8 80 FD-1015NS Non-Sterile HeartNet™ - Heart Positioning Device 20 4 80
  • 14. DMCM E D I C A L SupraGel™ is a cross-linked sterile amorphous hydrogel containing complex carbohydrates, CMC, propylene glycol and ultra pure water. Dependent on wound conditions, SupraGel™ has the ability to rehydrate dry necrotic tissue thus providing rapid wound debridement in addition to absorbing slough and excess exudates.Duetoitsfullycross-linkednature,nomacerationoccurs and SupraGel™ maintains its physical integrity throughout its use. wound care hydrogel TM SupraGel™ Wound Care Hydrogel12 Suitable for Cuts Grazes Rashes ExudingWounds Burns 1st & 2nd degree CavityWounds Leg Ulcers Product Code Description Units perbox Boxes percarton Total Units FD-1140 SupraGel™ Amorphous Sterile Hydrogel - 25g tube 20 12 240
  • 15. DMCM E D I C A L SupraCel™ sheet dressing is a cross-linked sterile hydrogel containing a solid polymer matrix with propylene glycol. Dependent on wound conditions, SupraCel™ has the ability to absorb wound exudates while maintaining an excellent moisture balance. Due to its fully cross-linked nature there will no maceration of the skin surrounding the wound. SupraCel™ maintains its physical integrity throughout its use. SupraCel™ Wound Care Hydrogel 13 Suitable for Burns 1st & 2nd degree Sunburn Blisters Rashes Grazes Leg Ulcers Post Operative Surgical Wounds Pressure Ulcers Product Code Description Units perbox Boxes percarton Total Units FD-1143 SupraCel™ Flat Sheet Sterile Hydrogel - 2”x 2”(50mm x 50mm) 100 4 400 FD-1141 SupraCel™ Flat Sheet Sterile Hydrogel - 4”x 4”(100mm x 100mm) 100 2 200 FD-1151 SupraCel™ Flat Sheet Sterile Hydrogel - 8”x 3”(200mm x 75mm) 50 2 100 FD-1204 SupraCel™ Flat Sheet Sterile Hydrogel – 8”x 8”(200mm x 200mm) 50 2 100
  • 16. DMC Medical Limited Corporate Headquarters Unit 2, Abbey House Shannon County Clare Ireland info@dmcmedical.net www.dmcmedical.net Telephone: Ireland: +353 61 718900 U.S.A.: +1 949 916 7253 Fax: Ireland: +353 61 718944 U.S.A.: +1 949 916 7254 DMC Medical Tech. & Mfg. Co. Ltd DaLang Town, Dongguan City Guangdong Province China info@dmcmedical.net www.dmcmedical.net w w w . d m c m e d i c a l . n e t DMCM E D I C A L