TEST REPORT
REPORT No.: R2DG1409040375E Date: September 23, 2014 Page 1 of 11
This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version
7.0.
This Test Report is issued by the Company subject to its Conditions of Issuance of Test Report printed overleaf or attached. The results
shown in this Test Report refer only to the sample(s) tested unless otherwise stated and such sample(s) are retained for 30days only.
This Test Report shall not be reproduced expected in full, without written approval of the Company.
Bay Area Compliance Laboratories Corp. (Dongguan)
69#Pulongcun,Puxinhu Industrial Zone,Tangxia Town Dongguan, Guangdong, China
Tel: +86-769-86858888 Fax: +86-769-86858891
AGC Lighting Co., Ltd
2nd Floor,2nd Building, DingFeng High-Tech Zone, Fuyuan 1st Road, FuYong Sub-district,
Bao'An, ShenZhen, China
Report on the submitted samples said to be:
***********************************************************************************************************************************
Summary of Test Results:
TEST REQUEST CONCLUSION
A
EU RoHS Directive 2011/65/EU and its amendment directives -XRF and Chemical
test(Lead, Cadmium, Mercury, Hexavalent Chromium, PBBs & PBDEs content) in the
components of submitted sample as the requirement of client
Pass
***********************************************************************************************************************************
Signed for and on behalf of
BACL
Checked by: ______________ Approved by: __________________
Jane Xu William Wei
Sample Name : Fixed Luminaires(LED High Bay Light)
Style/ Item No.①
: AGC-HB01-200
Additional Style/ Item No.②
: AGC-HB01-100, AGC-HB01-120, AGC-HB01-150
Sample Receiving Date : September 4, 2014
Testing Period : From September 4, 2014 to September 19, 2014
Results : Please refer to next page(s).
Remark :
① The Style/ Item No. is tested by the lab. ② The Additional Style/ Item No. are
declared by the applicant that they are Multiple Style/ Item No. with the tested Style/
Item No. in the applicant’s Declaration. The applicant undertakes all the
consequences caused by any false information or concealing.
TEST REPORT
REPORT No.: R2DG1409040375E Date: September 23, 2014 Page 2 of 11
This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version
7.0.
This Test Report is issued by the Company subject to its Conditions of Issuance of Test Report printed overleaf or attached. The results
shown in this Test Report refer only to the sample(s) tested unless otherwise stated and such sample(s) are retained for 30days only.
This Test Report shall not be reproduced expected in full, without written approval of the Company.
Bay Area Compliance Laboratories Corp. (Dongguan)
69#Pulongcun,Puxinhu Industrial Zone,Tangxia Town Dongguan, Guangdong, China
Tel: +86-769-86858888 Fax: +86-769-86858891
Technical Supervisor Laboratory Manager
TEST REPORT
REPORT No.: R2DG1409040375E Date: September 23, 2014 Page 3 of 11
This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version
7.0.
This Test Report is issued by the Company subject to its Conditions of Issuance of Test Report printed overleaf or attached. The results
shown in this Test Report refer only to the sample(s) tested unless otherwise stated and such sample(s) are retained for 30days only.
This Test Report shall not be reproduced expected in full, without written approval of the Company.
Bay Area Compliance Laboratories Corp. (Dongguan)
69#Pulongcun,Puxinhu Industrial Zone,Tangxia Town Dongguan, Guangdong, China
Tel: +86-769-86858888 Fax: +86-769-86858891
Results:
A、EU RoHS Directive 2011/65/EU and its amendment directives on XRF in the components of submitted
sample as the requirement of client
Test method: With reference to IEC62321-3-1:2013 screening by X-ray Fluorescence Spectroscopy (XRF)
Seq.
No.
Tested Part(s)
Results
Pb Cd Hg Cr Br
1 Black coated silvery metal(housing of lamp) BL BL BL BL ---
2* Silvery metal(screw for logo board, housing) BL BL BL IN ---
3 Black printed silvery metal(logo board, housing) BL BL BL BL ---
4*1
Silvery plated golden metal(spiral tube, connector, housing) OL BL BL BL ---
5*1
Silvery plated golden metal(cap for spiral tube, connector, housing) OL BL BL BL ---
6 Grey plastic(tube, connector, housing) BL BL BL BL BL
7 Black soft plastic(tube, connector, housing) BL BL BL BL BL
8 Translucent soft plastic(ring, connector, housing) BL BL BL BL BL
9 Black coated silvery metal(ring, front cover) BL BL BL BL ---
10* Silvery metal(screw for ring, front cover) BL BL BL IN ---
11 Clear glass(board, front cover) BL BL BL BL BL
12 Black soft plastic(sealing ring, front cover) BL BL BL BL BL
13 White glue(under base of LED) BL BL BL BL BL
14 White coated silvery metal(base of LED) BL BL BL BL ---
15 Yellow/white body(LED) BL BL BL BL BL
16*1
Silvery plated golden metal(wire fixer, base of LED) OL BL BL BL ---
17* Silvery metal(screw for wire fixer, base of LED) BL BL BL IN ---
18* Silvery metal(screw for base of LED) BL BL BL IN ---
19 Black coated silvery metal(pcb housing) BL BL BL BL ---
20* Black soft plastic(film, pcb housing) BL BL BL BL IN
21 Grey soft plastic(filling, pcb housing) BL BL BL BL BL
*****************************************************
TEST REPORT
REPORT No.: R2DG1409040375E Date: September 23, 2014 Page 4 of 11
This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version
7.0.
This Test Report is issued by the Company subject to its Conditions of Issuance of Test Report printed overleaf or attached. The results
shown in this Test Report refer only to the sample(s) tested unless otherwise stated and such sample(s) are retained for 30days only.
This Test Report shall not be reproduced expected in full, without written approval of the Company.
Bay Area Compliance Laboratories Corp. (Dongguan)
69#Pulongcun,Puxinhu Industrial Zone,Tangxia Town Dongguan, Guangdong, China
Tel: +86-769-86858888 Fax: +86-769-86858891
Seq.
No.
Tested Part(s)
Results
Pb Cd Hg Cr Br
22* Silvery metal(screw for pcb housing) BL BL BL IN ---
23* Silvery metal(big gasket for pcb housing) BL BL BL IN ---
24* Silvery metal(small gasket for pcb housing) BL BL BL IN ---
25* Silvery metal(hook for pcb housing) BL BL BL IN ---
26* Silvery metal(gasket for hook) BL BL BL IN ---
27*1
Silvery metal(tube, pcb housing) OL BL BL BL ---
28 Black coated silvery metal(cover of pcb housing) BL BL BL BL ---
29 Silvery metal(screw ,cover of pcb housing) BL BL BL BL ---
30 Black/red printed silvery plastic(label, cover of pcb housing) BL BL BL BL BL
31 Black plastic(spiral tube/cap, connector, pcb housing) BL BL BL BL BL
32 Black plastic(tube, connector, housing) BL BL BL BL BL
33 Black soft plastic(tube, connector, housing) BL BL BL BL BL
34 Black soft plastic(ring, connector, housing) BL BL BL BL BL
35 Black plastic(ring, connector, housing) BL BL BL BL BL
36 Black coated silvery metal(board on the pcb) BL BL BL BL ---
37 Silvery metal(screw, board on the pcb) BL BL BL BL ---
38 Silvery metal(combination screw, for pcb) BL BL BL BL ---
39 White printed black pvc(insulator, 2-core cable) BL BL BL BL BL
40 Black pvc(wire jacket, 2-core cable) BL BL BL BL BL
41 Red pvc(wire jacket, 2-core cable) BL BL BL BL BL
42 Coppery metal(conductor, 2-core cable) BL BL BL BL ---
43 Black soft plastic(stopper for 2-core cable) BL BL BL BL BL
44 Black pvc(insulator, 3-core cable) BL BL BL BL BL
*****************************************************
TEST REPORT
REPORT No.: R2DG1409040375E Date: September 23, 2014 Page 5 of 11
This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version
7.0.
This Test Report is issued by the Company subject to its Conditions of Issuance of Test Report printed overleaf or attached. The results
shown in this Test Report refer only to the sample(s) tested unless otherwise stated and such sample(s) are retained for 30days only.
This Test Report shall not be reproduced expected in full, without written approval of the Company.
Bay Area Compliance Laboratories Corp. (Dongguan)
69#Pulongcun,Puxinhu Industrial Zone,Tangxia Town Dongguan, Guangdong, China
Tel: +86-769-86858888 Fax: +86-769-86858891
Seq.
No.
Tested Part(s)
Results
Pb Cd Hg Cr Br
45 Brown pvc(wire jacket, 3-core cable) BL BL BL BL BL
46 Green/yellow pvc(wire jacket, 3-core cable) BL BL BL BL BL
47 Blue pvc(wire jacket, 3-core cable) BL BL BL BL BL
48 Coppery metal(conductor, 3-core cable) BL BL BL BL ---
-- = Not Conducted
* = Screening by XRF and detected by chemical method. The test results of chemical method please
refer to next pages.
*1
= As claimed by the material declaration submitted by the client, the materials of the sample No. 4,
5, 16, 27 are copper alloy. And according to RoHS directive 2011/65/EU and its amendments,
Lead is exempted as an alloying element in Copper containing up to 4% (40000ppm) by weight.
*****************************************************
TEST REPORT
REPORT No.: R2DG1409040375E Date: September 23, 2014 Page 6 of 11
This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version
7.0.
This Test Report is issued by the Company subject to its Conditions of Issuance of Test Report printed overleaf or attached. The results
shown in this Test Report refer only to the sample(s) tested unless otherwise stated and such sample(s) are retained for 30days only.
This Test Report shall not be reproduced expected in full, without written approval of the Company.
Bay Area Compliance Laboratories Corp. (Dongguan)
69#Pulongcun,Puxinhu Industrial Zone,Tangxia Town Dongguan, Guangdong, China
Tel: +86-769-86858888 Fax: +86-769-86858891
Remark:
ⅰ Results were obtained by XRF for primary screening, and further chemical testing by ICP (for Cd, Pb,
Hg), UV-Vis (for Cr(Ⅵ)) and GC-MS (for PBBs, PBDEs) are recommended to be performed, if the
concentration exceeds the below warning value according to IEC62321-3-1:2013.
Element Unit Polymers Metal Composite Material
Cd mg/kg
BL≤70-3σ<X
<130+3σ≤OL
BL≤70-3σ<X
<130+3σ≤OL
BL≤50-3σ<X
<150+3σ≤OL
Pb mg/kg
BL≤700-3σ<X
<1300+3σ≤OL
BL≤700-3σ<X
<1300+3σ≤OL
BL≤500-3σ<X
<1500+3σ≤OL
Hg mg/kg
BL≤700-3σ<X
<1300+3σ≤OL
BL≤700-3σ<X
<1300+3σ≤OL
BL≤500-3σ<X
<1500+3σ≤OL
Cr mg/kg BL≤700-3σ<X BL≤700-3σ<X BL≤500-3σ<X
Br mg/kg BL≤300-3σ<X -- BL≤250-3σ<X
Note:
*****************************************************
BL = Below Limit
OL = Over Limit
IN = Inconclusive
TEST REPORT
REPORT No.: R2DG1409040375E Date: September 23, 2014 Page 7 of 11
This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version
7.0.
This Test Report is issued by the Company subject to its Conditions of Issuance of Test Report printed overleaf or attached. The results
shown in this Test Report refer only to the sample(s) tested unless otherwise stated and such sample(s) are retained for 30days only.
This Test Report shall not be reproduced expected in full, without written approval of the Company.
Bay Area Compliance Laboratories Corp. (Dongguan)
69#Pulongcun,Puxinhu Industrial Zone,Tangxia Town Dongguan, Guangdong, China
Tel: +86-769-86858888 Fax: +86-769-86858891
ⅱ The XRF screening test for RoHS elements – The reading may be different to the actual content in the
sample be of non-uniformity composition.
ⅲ The maximum permissible limit is quoted from the RoHS directive 2011/65/EU:
RoHS Restricted Substances
Maximum Concentration Value (mg/kg)
(by weight in homogenous materials)
Cadmium (Cd) 100
Lead (Pb) 1000
Mercury (Hg) 1000
Hexavalent Chromium (Cr(Ⅵ)) 1000
Polybrominated biphenyls (PBBs) 1000
Polybrominated diphenylethers (PBDEs) 1000
Disclaimers:
This XRF Screening report is for reference purposes only. The applicant shall make its/his/her own judgment as
to whether the information provided in this XRF screening report is sufficient for its/his/her purposes.
The result shown in this XRF screening report will differ based on various factors, including but not limited to, the
sample size, thickness, area, surface flatness, equipment parameters and matrix effect (e.g. plastic, rubber, metal,
glass, ceramic etc.). Further wet chemical pre-treatment with relevant chemical equipment analysis are required to
obtain quantitative data.
*****************************************************
TEST REPORT
REPORT No.: R2DG1409040375E Date: September 23, 2014 Page 8 of 11
This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version
7.0.
This Test Report is issued by the Company subject to its Conditions of Issuance of Test Report printed overleaf or attached. The results
shown in this Test Report refer only to the sample(s) tested unless otherwise stated and such sample(s) are retained for 30days only.
This Test Report shall not be reproduced expected in full, without written approval of the Company.
Bay Area Compliance Laboratories Corp. (Dongguan)
69#Pulongcun,Puxinhu Industrial Zone,Tangxia Town Dongguan, Guangdong, China
Tel: +86-769-86858888 Fax: +86-769-86858891
The Test Results of Chemical Method:
Test method:
Hexavalent Chromium Content (For metal material):
With reference to IEC 62321 Ed 1.0:2008 Annex B, by boiling-water-extraction and analysis was performed by
UV-visible spectrophotometer (UV-Vis)
PBBs & PBDEs Content:
With reference to IEC 62321 Ed 1.0:2008 Annex A, by solvent extraction and analysis was
performed by gas chromatographic-mass spectrometer (GC-MS)
(1) The test results of Cr (Ⅵ)
Item MDL
Results
Limit
2 10 17 18 22
Hexavalent Chromium
(Cr (Ⅵ))
** Negative Negative Negative Negative Negative #
Conclusion / Pass Pass Pass Pass Pass
Item MDL
Results
Limit
23 24 25 26
Hexavalent Chromium
(Cr (Ⅵ))
** Negative Negative Negative Negative #
Conclusion / Pass Pass Pass Pass
********************************************************
TEST REPORT
REPORT No.: R2DG1409040375E Date: September 23, 2014 Page 9 of 11
This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version
7.0.
This Test Report is issued by the Company subject to its Conditions of Issuance of Test Report printed overleaf or attached. The results
shown in this Test Report refer only to the sample(s) tested unless otherwise stated and such sample(s) are retained for 30days only.
This Test Report shall not be reproduced expected in full, without written approval of the Company.
Bay Area Compliance Laboratories Corp. (Dongguan)
69#Pulongcun,Puxinhu Industrial Zone,Tangxia Town Dongguan, Guangdong, China
Tel: +86-769-86858888 Fax: +86-769-86858891
Note:
- N.D. = Not Detected or less than MDL
- Negative = Absence of Cr(Ⅵ) on the tested areas
- MDL = Method Detection Limit
- mg/kg = ppm
- ** =
Spot-test:
Negative = Absence of Cr(Ⅵ) coating, Positive = Presence of Cr(Ⅵ) coating;
(The tested sample should be further verified by boiling-water-extraction method if the spot test result
cannot be confirmed)
Boiling-water-extraction:
Negative = Absence of Cr(Ⅵ) coating;
Positive = Presence of Cr(VI) coating; the detected concentration in boiling-water-extraction solution is
equal or greater than 0.02 mg/kg with 50 cm2
sample surface area.
 
For corrosion protection coatings on metals: Information on storage conditions and production date of the
tested sample is unavailable and thus results of Cr(VI) represent status of the sample at the time of testing.
- # =
Positive indicates the presence of Cr(Ⅵ) on the tested areas and result be regarded as conflict with RoHS
requirement.
Negative indicates the absence of Cr(Ⅵ) on the tested areas and result be regarded as no conflict with
RoHS requirement.
********************************************************
TEST REPORT
REPORT No.: R2DG1409040375E Date: September 23, 2014 Page 10 of 11
This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version
7.0.
This Test Report is issued by the Company subject to its Conditions of Issuance of Test Report printed overleaf or attached. The results
shown in this Test Report refer only to the sample(s) tested unless otherwise stated and such sample(s) are retained for 30days only.
This Test Report shall not be reproduced expected in full, without written approval of the Company.
Bay Area Compliance Laboratories Corp. (Dongguan)
69#Pulongcun,Puxinhu Industrial Zone,Tangxia Town Dongguan, Guangdong, China
Tel: +86-769-86858888 Fax: +86-769-86858891
(2) The test results of PBBs & PBDEs
Item Unit MDL
Results
Limit
20
Polybrominated Biphenyls
(PBBs)
Monobromobiphenyl mg/kg 5 N.D.
Dibromobiphenyl mg/kg 5 N.D.
Tribromobiphenyl mg/kg 5 N.D.
Tetrabromobiphenyl mg/kg 5 N.D.
Pentabromobiphenyl mg/kg 5 N.D.
Hexabromobiphenyl mg/kg 5 N.D.
Heptabromobiphenyl mg/kg 5 N.D.
Octabromobiphenyl mg/kg 5 N.D.
Nonabromodiphenyl mg/kg 5 N.D.
Decabromodiphenyl mg/kg 5 N.D.
Total content mg/kg / N.D. 1000 mg/kg
Polybrominated Diphenylethers
(PBDEs)(Mon-Deca)
Monobromodiphenyl ether mg/kg 5 N.D.
Dibromodiphenyl ether mg/kg 5 N.D.
Tribromodiphenyl ether mg/kg 5 N.D.
Tetrabromodiphenyl ether mg/kg 5 N.D.
Pentabromodiphenyl ether mg/kg 5 N.D.
Hexabromodiphenyl ether mg/kg 5 N.D.
Heptabromodiphenyl ether mg/kg 5 N.D.
Octabromodiphenyl ether mg/kg 5 N.D.
Nonabromodiphenyl ether mg/kg 5 N.D.
Decabromodiphenyl ether mg/kg 5 N.D.
Total content mg/kg / N.D. 1000 mg/kg
Conclusion / / Pass
**********************************************************
TEST REPORT
REPORT No.: R2DG1409040375E Date: September 23, 2014 Page 11 of 11
This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version
7.0.
This Test Report is issued by the Company subject to its Conditions of Issuance of Test Report printed overleaf or attached. The results
shown in this Test Report refer only to the sample(s) tested unless otherwise stated and such sample(s) are retained for 30days only.
This Test Report shall not be reproduced expected in full, without written approval of the Company.
Bay Area Compliance Laboratories Corp. (Dongguan)
69#Pulongcun,Puxinhu Industrial Zone,Tangxia Town Dongguan, Guangdong, China
Tel: +86-769-86858888 Fax: +86-769-86858891
Note:
- N.D. = Not Detected or less than MDL
- mg/kg = ppm
- MDL = Method Detection Limit
- The results less than MDL are not taken into account while calculating the sum contents.
- Photo appendix is included.
Appendix
Photograph of Sample
BACL authenticate the photo on original report only
*** End of Report ***

More Related Content

Viewers also liked (7)

Red Cross Searching for El Niño Volunteers
Red Cross Searching for El Niño VolunteersRed Cross Searching for El Niño Volunteers
Red Cross Searching for El Niño Volunteers
 
Предписание Роспотребнадзорпредписание роспотребнадзор
Предписание Роспотребнадзорпредписание роспотребнадзорПредписание Роспотребнадзорпредписание роспотребнадзор
Предписание Роспотребнадзорпредписание роспотребнадзор
 
CV Conrado Duque 23 May 2016-1
CV Conrado Duque 23 May 2016-1CV Conrado Duque 23 May 2016-1
CV Conrado Duque 23 May 2016-1
 
Emerging and re emerging infectious diseases
Emerging and re emerging infectious diseasesEmerging and re emerging infectious diseases
Emerging and re emerging infectious diseases
 
El computador
El computadorEl computador
El computador
 
Non communicable disease
Non communicable diseaseNon communicable disease
Non communicable disease
 
CHILDREN'S MUSIC EDUCATION
CHILDREN'S MUSIC EDUCATIONCHILDREN'S MUSIC EDUCATION
CHILDREN'S MUSIC EDUCATION
 

Similar to AGC Lighting_high bay_RoHS cert

BeStar Digital 4 mm Mic
BeStar Digital 4 mm MicBeStar Digital 4 mm Mic
BeStar Digital 4 mm Mic
bjoernholdth
 
IP67 Test Report
IP67 Test ReportIP67 Test Report
IP67 Test Report
Leo Huang
 
CE Certificate
CE CertificateCE Certificate
CE Certificate
Leo Lyu
 
RoHs report
RoHs reportRoHs report
RoHs report
Leo Lyu
 

Similar to AGC Lighting_high bay_RoHS cert (20)

Tuv ROHS certificate --plastic pneumatic push in fittings
Tuv ROHS certificate --plastic pneumatic  push in fittingsTuv ROHS certificate --plastic pneumatic  push in fittings
Tuv ROHS certificate --plastic pneumatic push in fittings
 
Rohs certificate gyta53 dual jacket armored fiber optic cable for aerial duct...
Rohs certificate gyta53 dual jacket armored fiber optic cable for aerial duct...Rohs certificate gyta53 dual jacket armored fiber optic cable for aerial duct...
Rohs certificate gyta53 dual jacket armored fiber optic cable for aerial duct...
 
BeStar Digital 4 mm Mic
BeStar Digital 4 mm MicBeStar Digital 4 mm Mic
BeStar Digital 4 mm Mic
 
Cd4011b
Cd4011bCd4011b
Cd4011b
 
IP67 Test Report
IP67 Test ReportIP67 Test Report
IP67 Test Report
 
CE Certificate
CE CertificateCE Certificate
CE Certificate
 
A RoHS Update
A RoHS UpdateA RoHS Update
A RoHS Update
 
Cap dieu khien Belden 9418 18AWG 2 pair
Cap dieu khien Belden 9418 18AWG 2 pairCap dieu khien Belden 9418 18AWG 2 pair
Cap dieu khien Belden 9418 18AWG 2 pair
 
RoHs report
RoHs reportRoHs report
RoHs report
 
Pv7 mp24 sh420-ip
Pv7 mp24 sh420-ipPv7 mp24 sh420-ip
Pv7 mp24 sh420-ip
 
M25 Conduit ATEX & Flameproof EXD Barrier Glands Zone 1 & Zone 2 Hazardous Areas
M25 Conduit ATEX & Flameproof EXD Barrier Glands Zone 1 & Zone 2 Hazardous AreasM25 Conduit ATEX & Flameproof EXD Barrier Glands Zone 1 & Zone 2 Hazardous Areas
M25 Conduit ATEX & Flameproof EXD Barrier Glands Zone 1 & Zone 2 Hazardous Areas
 
Cd 4017
Cd 4017Cd 4017
Cd 4017
 
Dust sensor by optical sensing system gp2y1010au0f -isweek.com
Dust sensor by optical sensing system   gp2y1010au0f -isweek.comDust sensor by optical sensing system   gp2y1010au0f -isweek.com
Dust sensor by optical sensing system gp2y1010au0f -isweek.com
 
Auroras Lighting C-tick report sept2014 for down light IP65
Auroras Lighting C-tick report sept2014 for down light IP65Auroras Lighting C-tick report sept2014 for down light IP65
Auroras Lighting C-tick report sept2014 for down light IP65
 
000884
000884000884
000884
 
Merkel compact seal_l-27
Merkel compact seal_l-27Merkel compact seal_l-27
Merkel compact seal_l-27
 
LED 3W MR16 Spotlights LED 3W MR16灯杯
LED 3W MR16 Spotlights LED 3W MR16灯杯LED 3W MR16 Spotlights LED 3W MR16灯杯
LED 3W MR16 Spotlights LED 3W MR16灯杯
 
Environmental Product Declaration 2023.pptx
Environmental Product Declaration 2023.pptxEnvironmental Product Declaration 2023.pptx
Environmental Product Declaration 2023.pptx
 
CMA05MT900-A版承認書(FOR 訊舟)20090615
CMA05MT900-A版承認書(FOR 訊舟)20090615CMA05MT900-A版承認書(FOR 訊舟)20090615
CMA05MT900-A版承認書(FOR 訊舟)20090615
 
Strategic Sourcing Case Study on Aluminum Industry by Dragon Sourcing
Strategic Sourcing Case Study on Aluminum Industry by Dragon SourcingStrategic Sourcing Case Study on Aluminum Industry by Dragon Sourcing
Strategic Sourcing Case Study on Aluminum Industry by Dragon Sourcing
 

AGC Lighting_high bay_RoHS cert

  • 1. TEST REPORT REPORT No.: R2DG1409040375E Date: September 23, 2014 Page 1 of 11 This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This Test Report is issued by the Company subject to its Conditions of Issuance of Test Report printed overleaf or attached. The results shown in this Test Report refer only to the sample(s) tested unless otherwise stated and such sample(s) are retained for 30days only. This Test Report shall not be reproduced expected in full, without written approval of the Company. Bay Area Compliance Laboratories Corp. (Dongguan) 69#Pulongcun,Puxinhu Industrial Zone,Tangxia Town Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 AGC Lighting Co., Ltd 2nd Floor,2nd Building, DingFeng High-Tech Zone, Fuyuan 1st Road, FuYong Sub-district, Bao'An, ShenZhen, China Report on the submitted samples said to be: *********************************************************************************************************************************** Summary of Test Results: TEST REQUEST CONCLUSION A EU RoHS Directive 2011/65/EU and its amendment directives -XRF and Chemical test(Lead, Cadmium, Mercury, Hexavalent Chromium, PBBs & PBDEs content) in the components of submitted sample as the requirement of client Pass *********************************************************************************************************************************** Signed for and on behalf of BACL Checked by: ______________ Approved by: __________________ Jane Xu William Wei Sample Name : Fixed Luminaires(LED High Bay Light) Style/ Item No.① : AGC-HB01-200 Additional Style/ Item No.② : AGC-HB01-100, AGC-HB01-120, AGC-HB01-150 Sample Receiving Date : September 4, 2014 Testing Period : From September 4, 2014 to September 19, 2014 Results : Please refer to next page(s). Remark : ① The Style/ Item No. is tested by the lab. ② The Additional Style/ Item No. are declared by the applicant that they are Multiple Style/ Item No. with the tested Style/ Item No. in the applicant’s Declaration. The applicant undertakes all the consequences caused by any false information or concealing.
  • 2. TEST REPORT REPORT No.: R2DG1409040375E Date: September 23, 2014 Page 2 of 11 This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This Test Report is issued by the Company subject to its Conditions of Issuance of Test Report printed overleaf or attached. The results shown in this Test Report refer only to the sample(s) tested unless otherwise stated and such sample(s) are retained for 30days only. This Test Report shall not be reproduced expected in full, without written approval of the Company. Bay Area Compliance Laboratories Corp. (Dongguan) 69#Pulongcun,Puxinhu Industrial Zone,Tangxia Town Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 Technical Supervisor Laboratory Manager
  • 3. TEST REPORT REPORT No.: R2DG1409040375E Date: September 23, 2014 Page 3 of 11 This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This Test Report is issued by the Company subject to its Conditions of Issuance of Test Report printed overleaf or attached. The results shown in this Test Report refer only to the sample(s) tested unless otherwise stated and such sample(s) are retained for 30days only. This Test Report shall not be reproduced expected in full, without written approval of the Company. Bay Area Compliance Laboratories Corp. (Dongguan) 69#Pulongcun,Puxinhu Industrial Zone,Tangxia Town Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 Results: A、EU RoHS Directive 2011/65/EU and its amendment directives on XRF in the components of submitted sample as the requirement of client Test method: With reference to IEC62321-3-1:2013 screening by X-ray Fluorescence Spectroscopy (XRF) Seq. No. Tested Part(s) Results Pb Cd Hg Cr Br 1 Black coated silvery metal(housing of lamp) BL BL BL BL --- 2* Silvery metal(screw for logo board, housing) BL BL BL IN --- 3 Black printed silvery metal(logo board, housing) BL BL BL BL --- 4*1 Silvery plated golden metal(spiral tube, connector, housing) OL BL BL BL --- 5*1 Silvery plated golden metal(cap for spiral tube, connector, housing) OL BL BL BL --- 6 Grey plastic(tube, connector, housing) BL BL BL BL BL 7 Black soft plastic(tube, connector, housing) BL BL BL BL BL 8 Translucent soft plastic(ring, connector, housing) BL BL BL BL BL 9 Black coated silvery metal(ring, front cover) BL BL BL BL --- 10* Silvery metal(screw for ring, front cover) BL BL BL IN --- 11 Clear glass(board, front cover) BL BL BL BL BL 12 Black soft plastic(sealing ring, front cover) BL BL BL BL BL 13 White glue(under base of LED) BL BL BL BL BL 14 White coated silvery metal(base of LED) BL BL BL BL --- 15 Yellow/white body(LED) BL BL BL BL BL 16*1 Silvery plated golden metal(wire fixer, base of LED) OL BL BL BL --- 17* Silvery metal(screw for wire fixer, base of LED) BL BL BL IN --- 18* Silvery metal(screw for base of LED) BL BL BL IN --- 19 Black coated silvery metal(pcb housing) BL BL BL BL --- 20* Black soft plastic(film, pcb housing) BL BL BL BL IN 21 Grey soft plastic(filling, pcb housing) BL BL BL BL BL *****************************************************
  • 4. TEST REPORT REPORT No.: R2DG1409040375E Date: September 23, 2014 Page 4 of 11 This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This Test Report is issued by the Company subject to its Conditions of Issuance of Test Report printed overleaf or attached. The results shown in this Test Report refer only to the sample(s) tested unless otherwise stated and such sample(s) are retained for 30days only. This Test Report shall not be reproduced expected in full, without written approval of the Company. Bay Area Compliance Laboratories Corp. (Dongguan) 69#Pulongcun,Puxinhu Industrial Zone,Tangxia Town Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 Seq. No. Tested Part(s) Results Pb Cd Hg Cr Br 22* Silvery metal(screw for pcb housing) BL BL BL IN --- 23* Silvery metal(big gasket for pcb housing) BL BL BL IN --- 24* Silvery metal(small gasket for pcb housing) BL BL BL IN --- 25* Silvery metal(hook for pcb housing) BL BL BL IN --- 26* Silvery metal(gasket for hook) BL BL BL IN --- 27*1 Silvery metal(tube, pcb housing) OL BL BL BL --- 28 Black coated silvery metal(cover of pcb housing) BL BL BL BL --- 29 Silvery metal(screw ,cover of pcb housing) BL BL BL BL --- 30 Black/red printed silvery plastic(label, cover of pcb housing) BL BL BL BL BL 31 Black plastic(spiral tube/cap, connector, pcb housing) BL BL BL BL BL 32 Black plastic(tube, connector, housing) BL BL BL BL BL 33 Black soft plastic(tube, connector, housing) BL BL BL BL BL 34 Black soft plastic(ring, connector, housing) BL BL BL BL BL 35 Black plastic(ring, connector, housing) BL BL BL BL BL 36 Black coated silvery metal(board on the pcb) BL BL BL BL --- 37 Silvery metal(screw, board on the pcb) BL BL BL BL --- 38 Silvery metal(combination screw, for pcb) BL BL BL BL --- 39 White printed black pvc(insulator, 2-core cable) BL BL BL BL BL 40 Black pvc(wire jacket, 2-core cable) BL BL BL BL BL 41 Red pvc(wire jacket, 2-core cable) BL BL BL BL BL 42 Coppery metal(conductor, 2-core cable) BL BL BL BL --- 43 Black soft plastic(stopper for 2-core cable) BL BL BL BL BL 44 Black pvc(insulator, 3-core cable) BL BL BL BL BL *****************************************************
  • 5. TEST REPORT REPORT No.: R2DG1409040375E Date: September 23, 2014 Page 5 of 11 This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This Test Report is issued by the Company subject to its Conditions of Issuance of Test Report printed overleaf or attached. The results shown in this Test Report refer only to the sample(s) tested unless otherwise stated and such sample(s) are retained for 30days only. This Test Report shall not be reproduced expected in full, without written approval of the Company. Bay Area Compliance Laboratories Corp. (Dongguan) 69#Pulongcun,Puxinhu Industrial Zone,Tangxia Town Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 Seq. No. Tested Part(s) Results Pb Cd Hg Cr Br 45 Brown pvc(wire jacket, 3-core cable) BL BL BL BL BL 46 Green/yellow pvc(wire jacket, 3-core cable) BL BL BL BL BL 47 Blue pvc(wire jacket, 3-core cable) BL BL BL BL BL 48 Coppery metal(conductor, 3-core cable) BL BL BL BL --- -- = Not Conducted * = Screening by XRF and detected by chemical method. The test results of chemical method please refer to next pages. *1 = As claimed by the material declaration submitted by the client, the materials of the sample No. 4, 5, 16, 27 are copper alloy. And according to RoHS directive 2011/65/EU and its amendments, Lead is exempted as an alloying element in Copper containing up to 4% (40000ppm) by weight. *****************************************************
  • 6. TEST REPORT REPORT No.: R2DG1409040375E Date: September 23, 2014 Page 6 of 11 This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This Test Report is issued by the Company subject to its Conditions of Issuance of Test Report printed overleaf or attached. The results shown in this Test Report refer only to the sample(s) tested unless otherwise stated and such sample(s) are retained for 30days only. This Test Report shall not be reproduced expected in full, without written approval of the Company. Bay Area Compliance Laboratories Corp. (Dongguan) 69#Pulongcun,Puxinhu Industrial Zone,Tangxia Town Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 Remark: ⅰ Results were obtained by XRF for primary screening, and further chemical testing by ICP (for Cd, Pb, Hg), UV-Vis (for Cr(Ⅵ)) and GC-MS (for PBBs, PBDEs) are recommended to be performed, if the concentration exceeds the below warning value according to IEC62321-3-1:2013. Element Unit Polymers Metal Composite Material Cd mg/kg BL≤70-3σ<X <130+3σ≤OL BL≤70-3σ<X <130+3σ≤OL BL≤50-3σ<X <150+3σ≤OL Pb mg/kg BL≤700-3σ<X <1300+3σ≤OL BL≤700-3σ<X <1300+3σ≤OL BL≤500-3σ<X <1500+3σ≤OL Hg mg/kg BL≤700-3σ<X <1300+3σ≤OL BL≤700-3σ<X <1300+3σ≤OL BL≤500-3σ<X <1500+3σ≤OL Cr mg/kg BL≤700-3σ<X BL≤700-3σ<X BL≤500-3σ<X Br mg/kg BL≤300-3σ<X -- BL≤250-3σ<X Note: ***************************************************** BL = Below Limit OL = Over Limit IN = Inconclusive
  • 7. TEST REPORT REPORT No.: R2DG1409040375E Date: September 23, 2014 Page 7 of 11 This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This Test Report is issued by the Company subject to its Conditions of Issuance of Test Report printed overleaf or attached. The results shown in this Test Report refer only to the sample(s) tested unless otherwise stated and such sample(s) are retained for 30days only. This Test Report shall not be reproduced expected in full, without written approval of the Company. Bay Area Compliance Laboratories Corp. (Dongguan) 69#Pulongcun,Puxinhu Industrial Zone,Tangxia Town Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 ⅱ The XRF screening test for RoHS elements – The reading may be different to the actual content in the sample be of non-uniformity composition. ⅲ The maximum permissible limit is quoted from the RoHS directive 2011/65/EU: RoHS Restricted Substances Maximum Concentration Value (mg/kg) (by weight in homogenous materials) Cadmium (Cd) 100 Lead (Pb) 1000 Mercury (Hg) 1000 Hexavalent Chromium (Cr(Ⅵ)) 1000 Polybrominated biphenyls (PBBs) 1000 Polybrominated diphenylethers (PBDEs) 1000 Disclaimers: This XRF Screening report is for reference purposes only. The applicant shall make its/his/her own judgment as to whether the information provided in this XRF screening report is sufficient for its/his/her purposes. The result shown in this XRF screening report will differ based on various factors, including but not limited to, the sample size, thickness, area, surface flatness, equipment parameters and matrix effect (e.g. plastic, rubber, metal, glass, ceramic etc.). Further wet chemical pre-treatment with relevant chemical equipment analysis are required to obtain quantitative data. *****************************************************
  • 8. TEST REPORT REPORT No.: R2DG1409040375E Date: September 23, 2014 Page 8 of 11 This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This Test Report is issued by the Company subject to its Conditions of Issuance of Test Report printed overleaf or attached. The results shown in this Test Report refer only to the sample(s) tested unless otherwise stated and such sample(s) are retained for 30days only. This Test Report shall not be reproduced expected in full, without written approval of the Company. Bay Area Compliance Laboratories Corp. (Dongguan) 69#Pulongcun,Puxinhu Industrial Zone,Tangxia Town Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 The Test Results of Chemical Method: Test method: Hexavalent Chromium Content (For metal material): With reference to IEC 62321 Ed 1.0:2008 Annex B, by boiling-water-extraction and analysis was performed by UV-visible spectrophotometer (UV-Vis) PBBs & PBDEs Content: With reference to IEC 62321 Ed 1.0:2008 Annex A, by solvent extraction and analysis was performed by gas chromatographic-mass spectrometer (GC-MS) (1) The test results of Cr (Ⅵ) Item MDL Results Limit 2 10 17 18 22 Hexavalent Chromium (Cr (Ⅵ)) ** Negative Negative Negative Negative Negative # Conclusion / Pass Pass Pass Pass Pass Item MDL Results Limit 23 24 25 26 Hexavalent Chromium (Cr (Ⅵ)) ** Negative Negative Negative Negative # Conclusion / Pass Pass Pass Pass ********************************************************
  • 9. TEST REPORT REPORT No.: R2DG1409040375E Date: September 23, 2014 Page 9 of 11 This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This Test Report is issued by the Company subject to its Conditions of Issuance of Test Report printed overleaf or attached. The results shown in this Test Report refer only to the sample(s) tested unless otherwise stated and such sample(s) are retained for 30days only. This Test Report shall not be reproduced expected in full, without written approval of the Company. Bay Area Compliance Laboratories Corp. (Dongguan) 69#Pulongcun,Puxinhu Industrial Zone,Tangxia Town Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 Note: - N.D. = Not Detected or less than MDL - Negative = Absence of Cr(Ⅵ) on the tested areas - MDL = Method Detection Limit - mg/kg = ppm - ** = Spot-test: Negative = Absence of Cr(Ⅵ) coating, Positive = Presence of Cr(Ⅵ) coating; (The tested sample should be further verified by boiling-water-extraction method if the spot test result cannot be confirmed) Boiling-water-extraction: Negative = Absence of Cr(Ⅵ) coating; Positive = Presence of Cr(VI) coating; the detected concentration in boiling-water-extraction solution is equal or greater than 0.02 mg/kg with 50 cm2 sample surface area.   For corrosion protection coatings on metals: Information on storage conditions and production date of the tested sample is unavailable and thus results of Cr(VI) represent status of the sample at the time of testing. - # = Positive indicates the presence of Cr(Ⅵ) on the tested areas and result be regarded as conflict with RoHS requirement. Negative indicates the absence of Cr(Ⅵ) on the tested areas and result be regarded as no conflict with RoHS requirement. ********************************************************
  • 10. TEST REPORT REPORT No.: R2DG1409040375E Date: September 23, 2014 Page 10 of 11 This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This Test Report is issued by the Company subject to its Conditions of Issuance of Test Report printed overleaf or attached. The results shown in this Test Report refer only to the sample(s) tested unless otherwise stated and such sample(s) are retained for 30days only. This Test Report shall not be reproduced expected in full, without written approval of the Company. Bay Area Compliance Laboratories Corp. (Dongguan) 69#Pulongcun,Puxinhu Industrial Zone,Tangxia Town Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 (2) The test results of PBBs & PBDEs Item Unit MDL Results Limit 20 Polybrominated Biphenyls (PBBs) Monobromobiphenyl mg/kg 5 N.D. Dibromobiphenyl mg/kg 5 N.D. Tribromobiphenyl mg/kg 5 N.D. Tetrabromobiphenyl mg/kg 5 N.D. Pentabromobiphenyl mg/kg 5 N.D. Hexabromobiphenyl mg/kg 5 N.D. Heptabromobiphenyl mg/kg 5 N.D. Octabromobiphenyl mg/kg 5 N.D. Nonabromodiphenyl mg/kg 5 N.D. Decabromodiphenyl mg/kg 5 N.D. Total content mg/kg / N.D. 1000 mg/kg Polybrominated Diphenylethers (PBDEs)(Mon-Deca) Monobromodiphenyl ether mg/kg 5 N.D. Dibromodiphenyl ether mg/kg 5 N.D. Tribromodiphenyl ether mg/kg 5 N.D. Tetrabromodiphenyl ether mg/kg 5 N.D. Pentabromodiphenyl ether mg/kg 5 N.D. Hexabromodiphenyl ether mg/kg 5 N.D. Heptabromodiphenyl ether mg/kg 5 N.D. Octabromodiphenyl ether mg/kg 5 N.D. Nonabromodiphenyl ether mg/kg 5 N.D. Decabromodiphenyl ether mg/kg 5 N.D. Total content mg/kg / N.D. 1000 mg/kg Conclusion / / Pass **********************************************************
  • 11. TEST REPORT REPORT No.: R2DG1409040375E Date: September 23, 2014 Page 11 of 11 This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This Test Report is issued by the Company subject to its Conditions of Issuance of Test Report printed overleaf or attached. The results shown in this Test Report refer only to the sample(s) tested unless otherwise stated and such sample(s) are retained for 30days only. This Test Report shall not be reproduced expected in full, without written approval of the Company. Bay Area Compliance Laboratories Corp. (Dongguan) 69#Pulongcun,Puxinhu Industrial Zone,Tangxia Town Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 Note: - N.D. = Not Detected or less than MDL - mg/kg = ppm - MDL = Method Detection Limit - The results less than MDL are not taken into account while calculating the sum contents. - Photo appendix is included. Appendix Photograph of Sample BACL authenticate the photo on original report only *** End of Report ***