PERME® VAC-V1 Gas Permeability Tester
Yarina Gao
Trade5@labthink.cn
VAC-V1 is based on the differential pressure method, and is
professionally applicable to the determination of gas transmission
rate as well as solubility coefficient, diffusion coefficient and
permeability coefficient of plastic films, composite films, high
barrier materials, sheeting, metal foils, rubber, tires, and
permeable membranes.

Professional Technology

    Gas transmission rate, solubility coefficient, diffusion coefficient, and permeability coefficient of the
     specimen could be obtained at one operation
    The instrument comes with two test modes: proportional mode and standard mode
    Test range could be extended based on user requirements to test materials with high permeability
    High precision temperature control to meet different test conditions
    Test results could be easily obtained even at extreme condition by data fitting function, which could fit any
     temperature
    The instrument could be used to test poisonous, inflammable, and explosive gases (customization required)
    The instrument is controlled by a computer and test process is automatic
    Reference film for fast calibration to ensure accurate and universal test data
    Fast-access calibration port for temperature and humidity, and standard RS232 port for convenient calibration
     and data transfer
    Support Lystem™ Lab Data Sharing System for uniform management of test results and test reports


Test Principle

The pre-conditioned specimen is mounted in the gas diffusion cell as to form a sealed barrier between two
chambers. The lower-pressure chamber is firstly evacuated, followed by the evacuation of the entire cell. A flow
of gas is thereafter introduced into the evacuated higher-pressure chamber and a constant pressure difference is
generated between the two chambers. The gas permeates through the specimen from the higher pressure side into
the lower side. The gas permeability and other barrier properties of the specimen can be obtained by monitoring
the pressure changes in the lower chamber.
This test instrument conforms to the following standards:
ISO 15105-1, ISO 2556, GB/T1038-2000, ASTM D1434, JIS K7126-1, YBB 00082003


Applications

This test instrument is applicable to the determination of gas permeability of:
                                                 Including plastic films, plastic composite films, paper-plastic
                               Films             composite films, geomembranes, coextruded films, aluminized films,
      Basic
                                                 aluminum foil, aluminum foil composite films, and many others
    Applications
                                                 Including engineering plastics, rubber, and building materials, e.g. PP,
                              Sheeting
                                                 PVC, and PVDC

     Labthink Instruments Co., Ltd.144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86-531-85068566 FAX: +86-531-85812140
                                                                            w w w.labthinkinter n atio n al.co m.cn
Test the permeability of various types of gases, e.g. O 2, CO2, N2, Air
                          Various Gases
                                                and Helium
                          Inflammable,
                                                Test the permeability of various films to inflammable, explosive gases
                         Explosive Gases
                                                Test gas permeability of various sorts of biodegradable films, e.g.
                      Biodegradable Films
                                                starch-based biodegradable bags
                           Materials for
                                                This instrument can test the Helium permeability of airship gas bag
                        Aerospace Usage
    Extended
                                                Test gas permeability of paper and paper-plastic composite materials,
   Applications          Paper and Paper
                                                e.g. aluminized paper, Tetra Pak sheeting, paper bowl for instant
                              Board
                                                noodles and disposable paper cup
                           Paint Films          Test gas permeability of substrates coated with paint films
                        Glass Fiber Cloth       Including glass fiber cloth and paper materials, e.g. Teflon paint cloth,
                            and Paper           Teflon welding cloth, and Teflon Silicon Rubber Cloth
                       Soft Tube Materials      Including various types of cosmetic tubes, aluminum-plastic tubes, and
                          for Cosmetics         toothpaste tubes
                         Rubber Sheeting        Including various sorts of rubber sheeting, e.g. car tires


Technical Specifications

     Specifications                                                        Film
                                                                   3   2
                                               0.1 ~ 100,000 cm /m · 0.1MPa (standard volume)
                                                                   24h·
       Test Range
                                             At least 600,000 cm3/m2· 0.1MPa (extended volume)
                                                                    24h·
  Number of Specimens                                                        1
   Vacuum Resolution                                                       0.1Pa
 Vacuum Degree of Test
                                                                           <20Pa
      Chamber
      Temperature                                             Room temperature ~ 50°
                                                                                   C
        Accuracy                                                           ± C
                                                                            0.1°
     Specimen Size                                                         Φ97mm
        Test Area                                                  38.48 cm2(Φ70 mm)
        Test Gas                                        O2, N2, and CO2(not in supply scope)
     Test Pressure                                          -0.1MPa ~ +0.1MPa(standard)
  Gas Supply Pressure                                              0.4MPa ~ 0.6MPa
        Port Size                                                  Ф6 mm PU Tubing
    Instrument Size                                   680 mm(L) x 565 mm(W) x 550 mm(H)
         Power                                                      AC 220V 50Hz
       Net Weight                                                          130 kg


Configurations

     Standard             Mainbody, Professional Software, Round Sample Cutter, Vacuum Grease, Rapid
   Configurations         Quantitative Filter Paper, and Vacuum Pump (Imported)
   Optional Parts         Blades for Sample Cutter, Vacuum Grease, Vacuum Pump Oil, and Rapid Quantitative

    Labthink Instruments Co., Ltd.144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86-531-85068566 FAX: +86-531-85812140
                                                                            w w w.labthinkinter n atio n al.co m.cn
Filter Paper
                      1. The gas supply port of the instrument is Φ6 mm PU Tubing;
    Note
                      2. Customers will need to prepare for gas supply.




Labthink Instruments Co., Ltd.144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86-531-85068566 FAX: +86-531-85812140
                                                                       w w w.labthinkinter n atio n al.co m.cn

More Related Content

What's hot

Particulado respirável Niosh
Particulado respirável NioshParticulado respirável Niosh
Particulado respirável NioshAne Costa
 
W3 330-Water-Vapor-Transmission-rate-Test-System
W3 330-Water-Vapor-Transmission-rate-Test-SystemW3 330-Water-Vapor-Transmission-rate-Test-System
W3 330-Water-Vapor-Transmission-rate-Test-SystemLabthink International,Inc.
 
Ludwig Vinches et al._Study on the penetration of ti o2 nanoparticles through...
Ludwig Vinches et al._Study on the penetration of ti o2 nanoparticles through...Ludwig Vinches et al._Study on the penetration of ti o2 nanoparticles through...
Ludwig Vinches et al._Study on the penetration of ti o2 nanoparticles through...Ne3LS_Network
 
Viscol 10 series Fully Automatic Kinematic Viscometer
Viscol 10 series Fully Automatic Kinematic Viscometer Viscol 10 series Fully Automatic Kinematic Viscometer
Viscol 10 series Fully Automatic Kinematic Viscometer OmarSARKAHIAH
 
High Flow Filter for UPW Applications – A Field Case Study
High Flow Filter for UPW Applications – A Field Case StudyHigh Flow Filter for UPW Applications – A Field Case Study
High Flow Filter for UPW Applications – A Field Case Studygvanscho
 
Peek mod properties datasheet tecapeek_pvx_ensinger
Peek mod  properties datasheet  tecapeek_pvx_ensingerPeek mod  properties datasheet  tecapeek_pvx_ensinger
Peek mod properties datasheet tecapeek_pvx_ensingermandalika3
 
Melt Flow Index Tester, Melt Flow Index Tester Manufacturers and Suppliers In...
Melt Flow Index Tester, Melt Flow Index Tester Manufacturers and Suppliers In...Melt Flow Index Tester, Melt Flow Index Tester Manufacturers and Suppliers In...
Melt Flow Index Tester, Melt Flow Index Tester Manufacturers and Suppliers In...Presto Group
 
Astm c117 stm_materials_finer_than_75mm_no.200_sieve_in_mine
Astm c117 stm_materials_finer_than_75mm_no.200_sieve_in_mineAstm c117 stm_materials_finer_than_75mm_no.200_sieve_in_mine
Astm c117 stm_materials_finer_than_75mm_no.200_sieve_in_mineKemal Yücel
 
SMC(FRP) Valve Catalogue1
SMC(FRP) Valve Catalogue1SMC(FRP) Valve Catalogue1
SMC(FRP) Valve Catalogue1jejujung
 
Method developmment, trouble shooting ppt
Method developmment, trouble shooting pptMethod developmment, trouble shooting ppt
Method developmment, trouble shooting pptrdeepthi1
 
Paper packaging testing instruments
Paper packaging testing instrumentsPaper packaging testing instruments
Paper packaging testing instrumentsPacorr Testing
 

What's hot (15)

Particulado respirável Niosh
Particulado respirável NioshParticulado respirável Niosh
Particulado respirável Niosh
 
W3 330-Water-Vapor-Transmission-rate-Test-System
W3 330-Water-Vapor-Transmission-rate-Test-SystemW3 330-Water-Vapor-Transmission-rate-Test-System
W3 330-Water-Vapor-Transmission-rate-Test-System
 
Ludwig Vinches et al._Study on the penetration of ti o2 nanoparticles through...
Ludwig Vinches et al._Study on the penetration of ti o2 nanoparticles through...Ludwig Vinches et al._Study on the penetration of ti o2 nanoparticles through...
Ludwig Vinches et al._Study on the penetration of ti o2 nanoparticles through...
 
Viscol 10 series Fully Automatic Kinematic Viscometer
Viscol 10 series Fully Automatic Kinematic Viscometer Viscol 10 series Fully Automatic Kinematic Viscometer
Viscol 10 series Fully Automatic Kinematic Viscometer
 
Wvtr and otr
Wvtr and otrWvtr and otr
Wvtr and otr
 
G2-131-Gas-Permeability-Tester
G2-131-Gas-Permeability-TesterG2-131-Gas-Permeability-Tester
G2-131-Gas-Permeability-Tester
 
Safe Environmental Analytics
Safe Environmental Analytics Safe Environmental Analytics
Safe Environmental Analytics
 
High Flow Filter for UPW Applications – A Field Case Study
High Flow Filter for UPW Applications – A Field Case StudyHigh Flow Filter for UPW Applications – A Field Case Study
High Flow Filter for UPW Applications – A Field Case Study
 
G2 132-Gas-Permeability-Tester
G2 132-Gas-Permeability-TesterG2 132-Gas-Permeability-Tester
G2 132-Gas-Permeability-Tester
 
Peek mod properties datasheet tecapeek_pvx_ensinger
Peek mod  properties datasheet  tecapeek_pvx_ensingerPeek mod  properties datasheet  tecapeek_pvx_ensinger
Peek mod properties datasheet tecapeek_pvx_ensinger
 
Melt Flow Index Tester, Melt Flow Index Tester Manufacturers and Suppliers In...
Melt Flow Index Tester, Melt Flow Index Tester Manufacturers and Suppliers In...Melt Flow Index Tester, Melt Flow Index Tester Manufacturers and Suppliers In...
Melt Flow Index Tester, Melt Flow Index Tester Manufacturers and Suppliers In...
 
Astm c117 stm_materials_finer_than_75mm_no.200_sieve_in_mine
Astm c117 stm_materials_finer_than_75mm_no.200_sieve_in_mineAstm c117 stm_materials_finer_than_75mm_no.200_sieve_in_mine
Astm c117 stm_materials_finer_than_75mm_no.200_sieve_in_mine
 
SMC(FRP) Valve Catalogue1
SMC(FRP) Valve Catalogue1SMC(FRP) Valve Catalogue1
SMC(FRP) Valve Catalogue1
 
Method developmment, trouble shooting ppt
Method developmment, trouble shooting pptMethod developmment, trouble shooting ppt
Method developmment, trouble shooting ppt
 
Paper packaging testing instruments
Paper packaging testing instrumentsPaper packaging testing instruments
Paper packaging testing instruments
 

Similar to Plastic packaging gas barrier property tester

Tsy w3 Electrolytic Detection Method Water Vapor Permeability Tester
Tsy w3 Electrolytic Detection Method Water Vapor Permeability TesterTsy w3 Electrolytic Detection Method Water Vapor Permeability Tester
Tsy w3 Electrolytic Detection Method Water Vapor Permeability TesterLabthink Instruments Co., Ltd
 
Dm2 330-Differential-and-Equal-Pressure-Method-Gas-Permeability-Tester
Dm2 330-Differential-and-Equal-Pressure-Method-Gas-Permeability-TesterDm2 330-Differential-and-Equal-Pressure-Method-Gas-Permeability-Tester
Dm2 330-Differential-and-Equal-Pressure-Method-Gas-Permeability-TesterLabthink International,Inc.
 
DM2-330-Films & Packages Differential and Equal Pressure Method Gas Permeabil...
DM2-330-Films & Packages Differential and Equal Pressure Method Gas Permeabil...DM2-330-Films & Packages Differential and Equal Pressure Method Gas Permeabil...
DM2-330-Films & Packages Differential and Equal Pressure Method Gas Permeabil...Labthink International,Inc.
 
Dm2-330-Differential-and-Equal-Pressure-Method-Gas-Permeability-Tester
Dm2-330-Differential-and-Equal-Pressure-Method-Gas-Permeability-TesterDm2-330-Differential-and-Equal-Pressure-Method-Gas-Permeability-Tester
Dm2-330-Differential-and-Equal-Pressure-Method-Gas-Permeability-TesterEmilywu12
 
water vapor permeability tester for flexible packaging
water vapor permeability tester for flexible packaging water vapor permeability tester for flexible packaging
water vapor permeability tester for flexible packaging Labthink Instruments Co., Ltd
 
TSY-W3-Electrolytic-Detection-Method-Water-Vapor-Permeability-Tester
TSY-W3-Electrolytic-Detection-Method-Water-Vapor-Permeability-TesterTSY-W3-Electrolytic-Detection-Method-Water-Vapor-Permeability-Tester
TSY-W3-Electrolytic-Detection-Method-Water-Vapor-Permeability-TesterLabthink International,Inc.
 
G2 132-Gas-permeability-tester
G2 132-Gas-permeability-testerG2 132-Gas-permeability-tester
G2 132-Gas-permeability-testerEmilywu12
 
G2-131-Gas Permeability Tester for Films and Sheeting
G2-131-Gas Permeability Tester for Films and SheetingG2-131-Gas Permeability Tester for Films and Sheeting
G2-131-Gas Permeability Tester for Films and SheetingLabthink International,Inc.
 
G2 131-Gas-permeability-tester
G2 131-Gas-permeability-testerG2 131-Gas-permeability-tester
G2 131-Gas-permeability-testerEmilywu12
 

Similar to Plastic packaging gas barrier property tester (20)

VAC-V2-Gas-Permeability-Tester
VAC-V2-Gas-Permeability-TesterVAC-V2-Gas-Permeability-Tester
VAC-V2-Gas-Permeability-Tester
 
VAC-V3-Gas-Permeability-Tester
VAC-V3-Gas-Permeability-TesterVAC-V3-Gas-Permeability-Tester
VAC-V3-Gas-Permeability-Tester
 
Tsy w3 Electrolytic Detection Method Water Vapor Permeability Tester
Tsy w3 Electrolytic Detection Method Water Vapor Permeability TesterTsy w3 Electrolytic Detection Method Water Vapor Permeability Tester
Tsy w3 Electrolytic Detection Method Water Vapor Permeability Tester
 
VAC-V1-Gas-Permeability-Tester
VAC-V1-Gas-Permeability-TesterVAC-V1-Gas-Permeability-Tester
VAC-V1-Gas-Permeability-Tester
 
VAC-VBS-Gas-Permeability-Tester
VAC-VBS-Gas-Permeability-TesterVAC-VBS-Gas-Permeability-Tester
VAC-VBS-Gas-Permeability-Tester
 
Dm2 330-Differential-and-Equal-Pressure-Method-Gas-Permeability-Tester
Dm2 330-Differential-and-Equal-Pressure-Method-Gas-Permeability-TesterDm2 330-Differential-and-Equal-Pressure-Method-Gas-Permeability-Tester
Dm2 330-Differential-and-Equal-Pressure-Method-Gas-Permeability-Tester
 
DM2-330-Films & Packages Differential and Equal Pressure Method Gas Permeabil...
DM2-330-Films & Packages Differential and Equal Pressure Method Gas Permeabil...DM2-330-Films & Packages Differential and Equal Pressure Method Gas Permeabil...
DM2-330-Films & Packages Differential and Equal Pressure Method Gas Permeabil...
 
Dm2-330-Differential-and-Equal-Pressure-Method-Gas-Permeability-Tester
Dm2-330-Differential-and-Equal-Pressure-Method-Gas-Permeability-TesterDm2-330-Differential-and-Equal-Pressure-Method-Gas-Permeability-Tester
Dm2-330-Differential-and-Equal-Pressure-Method-Gas-Permeability-Tester
 
water vapor permeability tester for flexible packaging
water vapor permeability tester for flexible packaging water vapor permeability tester for flexible packaging
water vapor permeability tester for flexible packaging
 
TSY-W3-Electrolytic-Detection-Method-Water-Vapor-Permeability-Tester
TSY-W3-Electrolytic-Detection-Method-Water-Vapor-Permeability-TesterTSY-W3-Electrolytic-Detection-Method-Water-Vapor-Permeability-Tester
TSY-W3-Electrolytic-Detection-Method-Water-Vapor-Permeability-Tester
 
OX2-231-Oxygen-Permeability-Tester
OX2-231-Oxygen-Permeability-TesterOX2-231-Oxygen-Permeability-Tester
OX2-231-Oxygen-Permeability-Tester
 
W3-030-Water-Vapor-Transmission-Rate-Tester
W3-030-Water-Vapor-Transmission-Rate-TesterW3-030-Water-Vapor-Transmission-Rate-Tester
W3-030-Water-Vapor-Transmission-Rate-Tester
 
W3 0120-Water-Vapor-Transmission-rate-Tester
W3 0120-Water-Vapor-Transmission-rate-TesterW3 0120-Water-Vapor-Transmission-rate-Tester
W3 0120-Water-Vapor-Transmission-rate-Tester
 
G2 132-Gas-permeability-tester
G2 132-Gas-permeability-testerG2 132-Gas-permeability-tester
G2 132-Gas-permeability-tester
 
G2 132-Gas-Permeability-Tester-for-Paint-Films
G2 132-Gas-Permeability-Tester-for-Paint-FilmsG2 132-Gas-Permeability-Tester-for-Paint-Films
G2 132-Gas-Permeability-Tester-for-Paint-Films
 
Mixed Gas Permeability Analyzer
Mixed Gas Permeability AnalyzerMixed Gas Permeability Analyzer
Mixed Gas Permeability Analyzer
 
Hot Tack Tester for plastic packaging
Hot Tack Tester for plastic packaging Hot Tack Tester for plastic packaging
Hot Tack Tester for plastic packaging
 
G2/110 Separation Membrane Permeability Analyzer
G2/110 Separation Membrane Permeability AnalyzerG2/110 Separation Membrane Permeability Analyzer
G2/110 Separation Membrane Permeability Analyzer
 
G2-131-Gas Permeability Tester for Films and Sheeting
G2-131-Gas Permeability Tester for Films and SheetingG2-131-Gas Permeability Tester for Films and Sheeting
G2-131-Gas Permeability Tester for Films and Sheeting
 
G2 131-Gas-permeability-tester
G2 131-Gas-permeability-testerG2 131-Gas-permeability-tester
G2 131-Gas-permeability-tester
 

More from Labthink Instruments Co., Ltd

90 Degree Adhesive Peel Strength Test on a Tensile Testing Machine
90 Degree Adhesive Peel Strength Test on a Tensile Testing Machine90 Degree Adhesive Peel Strength Test on a Tensile Testing Machine
90 Degree Adhesive Peel Strength Test on a Tensile Testing MachineLabthink Instruments Co., Ltd
 
Tensile strength testing machine for flexible materials
Tensile strength testing machine for flexible materials Tensile strength testing machine for flexible materials
Tensile strength testing machine for flexible materials Labthink Instruments Co., Ltd
 

More from Labthink Instruments Co., Ltd (20)

1 oxygen permeability test method of pudding cups
1   oxygen permeability test method of pudding cups1   oxygen permeability test method of pudding cups
1 oxygen permeability test method of pudding cups
 
1 oxygen permeability test method of pudding cups
1   oxygen permeability test method of pudding cups1   oxygen permeability test method of pudding cups
1 oxygen permeability test method of pudding cups
 
1 oxygen permeability test method of pudding cups
1   oxygen permeability test method of pudding cups1   oxygen permeability test method of pudding cups
1 oxygen permeability test method of pudding cups
 
90 Degree Adhesive Peel Strength Test on a Tensile Testing Machine
90 Degree Adhesive Peel Strength Test on a Tensile Testing Machine90 Degree Adhesive Peel Strength Test on a Tensile Testing Machine
90 Degree Adhesive Peel Strength Test on a Tensile Testing Machine
 
Plastic film hot tack test
Plastic film hot tack testPlastic film hot tack test
Plastic film hot tack test
 
Plastic film hot tack test
Plastic film hot tack testPlastic film hot tack test
Plastic film hot tack test
 
Medical blister leak and seal strength test
Medical blister leak and seal strength testMedical blister leak and seal strength test
Medical blister leak and seal strength test
 
Medical blister leak and seal strength test
Medical blister leak and seal strength testMedical blister leak and seal strength test
Medical blister leak and seal strength test
 
Break force test of ampoule bottle
Break force test of ampoule bottleBreak force test of ampoule bottle
Break force test of ampoule bottle
 
Xlw (g6) auto tensile tester
Xlw (g6) auto tensile testerXlw (g6) auto tensile tester
Xlw (g6) auto tensile tester
 
Ft f1 fogging tester
Ft f1 fogging testerFt f1 fogging tester
Ft f1 fogging tester
 
Box Compression Tester
Box Compression TesterBox Compression Tester
Box Compression Tester
 
Xyd 15 k
Xyd 15 kXyd 15 k
Xyd 15 k
 
Tensile strength at break tester
Tensile strength at break testerTensile strength at break tester
Tensile strength at break tester
 
Tension and Elongation rate tester
Tension and Elongation rate testerTension and Elongation rate tester
Tension and Elongation rate tester
 
Material universal testing machine
Material universal testing machine Material universal testing machine
Material universal testing machine
 
Puncture strength tester for packaging
Puncture strength tester for packaging Puncture strength tester for packaging
Puncture strength tester for packaging
 
Tensile Tester
Tensile TesterTensile Tester
Tensile Tester
 
Tensile strength testing machine for flexible materials
Tensile strength testing machine for flexible materials Tensile strength testing machine for flexible materials
Tensile strength testing machine for flexible materials
 
Air permeability Tester
Air permeability TesterAir permeability Tester
Air permeability Tester
 

Plastic packaging gas barrier property tester

  • 1. PERME® VAC-V1 Gas Permeability Tester Yarina Gao Trade5@labthink.cn VAC-V1 is based on the differential pressure method, and is professionally applicable to the determination of gas transmission rate as well as solubility coefficient, diffusion coefficient and permeability coefficient of plastic films, composite films, high barrier materials, sheeting, metal foils, rubber, tires, and permeable membranes. Professional Technology  Gas transmission rate, solubility coefficient, diffusion coefficient, and permeability coefficient of the specimen could be obtained at one operation  The instrument comes with two test modes: proportional mode and standard mode  Test range could be extended based on user requirements to test materials with high permeability  High precision temperature control to meet different test conditions  Test results could be easily obtained even at extreme condition by data fitting function, which could fit any temperature  The instrument could be used to test poisonous, inflammable, and explosive gases (customization required)  The instrument is controlled by a computer and test process is automatic  Reference film for fast calibration to ensure accurate and universal test data  Fast-access calibration port for temperature and humidity, and standard RS232 port for convenient calibration and data transfer  Support Lystem™ Lab Data Sharing System for uniform management of test results and test reports Test Principle The pre-conditioned specimen is mounted in the gas diffusion cell as to form a sealed barrier between two chambers. The lower-pressure chamber is firstly evacuated, followed by the evacuation of the entire cell. A flow of gas is thereafter introduced into the evacuated higher-pressure chamber and a constant pressure difference is generated between the two chambers. The gas permeates through the specimen from the higher pressure side into the lower side. The gas permeability and other barrier properties of the specimen can be obtained by monitoring the pressure changes in the lower chamber. This test instrument conforms to the following standards: ISO 15105-1, ISO 2556, GB/T1038-2000, ASTM D1434, JIS K7126-1, YBB 00082003 Applications This test instrument is applicable to the determination of gas permeability of: Including plastic films, plastic composite films, paper-plastic Films composite films, geomembranes, coextruded films, aluminized films, Basic aluminum foil, aluminum foil composite films, and many others Applications Including engineering plastics, rubber, and building materials, e.g. PP, Sheeting PVC, and PVDC Labthink Instruments Co., Ltd.144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86-531-85068566 FAX: +86-531-85812140 w w w.labthinkinter n atio n al.co m.cn
  • 2. Test the permeability of various types of gases, e.g. O 2, CO2, N2, Air Various Gases and Helium Inflammable, Test the permeability of various films to inflammable, explosive gases Explosive Gases Test gas permeability of various sorts of biodegradable films, e.g. Biodegradable Films starch-based biodegradable bags Materials for This instrument can test the Helium permeability of airship gas bag Aerospace Usage Extended Test gas permeability of paper and paper-plastic composite materials, Applications Paper and Paper e.g. aluminized paper, Tetra Pak sheeting, paper bowl for instant Board noodles and disposable paper cup Paint Films Test gas permeability of substrates coated with paint films Glass Fiber Cloth Including glass fiber cloth and paper materials, e.g. Teflon paint cloth, and Paper Teflon welding cloth, and Teflon Silicon Rubber Cloth Soft Tube Materials Including various types of cosmetic tubes, aluminum-plastic tubes, and for Cosmetics toothpaste tubes Rubber Sheeting Including various sorts of rubber sheeting, e.g. car tires Technical Specifications Specifications Film 3 2 0.1 ~ 100,000 cm /m · 0.1MPa (standard volume) 24h· Test Range At least 600,000 cm3/m2· 0.1MPa (extended volume) 24h· Number of Specimens 1 Vacuum Resolution 0.1Pa Vacuum Degree of Test <20Pa Chamber Temperature Room temperature ~ 50° C Accuracy ± C 0.1° Specimen Size Φ97mm Test Area 38.48 cm2(Φ70 mm) Test Gas O2, N2, and CO2(not in supply scope) Test Pressure -0.1MPa ~ +0.1MPa(standard) Gas Supply Pressure 0.4MPa ~ 0.6MPa Port Size Ф6 mm PU Tubing Instrument Size 680 mm(L) x 565 mm(W) x 550 mm(H) Power AC 220V 50Hz Net Weight 130 kg Configurations Standard Mainbody, Professional Software, Round Sample Cutter, Vacuum Grease, Rapid Configurations Quantitative Filter Paper, and Vacuum Pump (Imported) Optional Parts Blades for Sample Cutter, Vacuum Grease, Vacuum Pump Oil, and Rapid Quantitative Labthink Instruments Co., Ltd.144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86-531-85068566 FAX: +86-531-85812140 w w w.labthinkinter n atio n al.co m.cn
  • 3. Filter Paper 1. The gas supply port of the instrument is Φ6 mm PU Tubing; Note 2. Customers will need to prepare for gas supply. Labthink Instruments Co., Ltd.144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86-531-85068566 FAX: +86-531-85812140 w w w.labthinkinter n atio n al.co m.cn