1. Vibration Report
for the
Month of May 2010
Advanced Monitoring Service
55 Leedham Street Suite 3-6 South Attleboro Ma. 02703 774-219-9947
2. Enclosed is a current report of the data collected during our visit to CCE Elmsford, NY on June
23, 2005. This report will give you an overview of all data collected, the recommended action ,
and their priority levels. Please feel free to contact our office with any questions or concerns
you may have regarding this report or the services you received.
June 23, 2005
CCE Bottling Company of New York
111 View Park Drive
Elmsford, NY 10523
Attention : Mr. Michael P. Rose
Subject : Monthly Readings for the PdM Program
Dear Mike,
Sincerely,
Edward A. Bartnikowski
Reliability Consultant
Advanced Monitoring Service
55 Leedham Street Suite 3-6 South Attleboro Ma. 02703 774-219-9947
4. Alarm Report Summary
MACHINE ALARM PAGE PROBLEM
#3 Line Vacuum Pump CRITICAL 11 Lube
#7 Ammonia Compressor CRITICAL 5 Alignment
#1 Line Booster Pump CRITICAL 7 Balance
#2 Line Vacuum Pump CRITICAL 8 Loose
#3 Line Booster Pump HIGH 9 Lube
#2 Fridge Compressor HIGH 2 Mounting
#1 Air Compressor HIGH 3 Alignment
#3 Line Prod. Pump HIGH 10 Lube
#9 Ammonia Compressor LOW 4 Belt Alignment
#5 Ammonia Compressor LOW 1 Alignment
#1 Line Main Drive LOW 6 Electrical
5. DATE :
March 25,2010
COMPANY :
East Hartford
AREA :
Can Line
PRIORITY :
CRITICAL
PROBLEM STATEMENT :
INSPECT INPUT BEARING FOR PROPER MOUNTING AND WEAR
MACHINE NAME :
Seamier
ITEM NUMBER :
MACHINE DRAWING :
FINDINGS :
The spectrum on the motor indicates
an high nonsynchours peaks in the radial
position which is a indication of a bearing
problem.
RECOMMENDATIONS :
Recommend inspecting unit for
proper wear and replace or rebuild input
bearing housing as needed. .
PAGE : 7
M1A
M1R
M1V
M2A
M2R
M2V
P1A
P1R
P1V
7. DATE :
June 23, 2005
COMPANY :
East Hartford
AREA :
Ammonia room
PRIORITY :
LOW
PROBLEM STATEMENT :
INSPECT BELTS FOR PROPER WEAR AND FIT
MACHINE NAME :
#2 Ammonia Compressor
ITEM NUMBER :
MACHINE DRAWING :
FINDINGS :
The spectrum on the motor indicates
an increase in 1x belt with no harmonics,
which is a indication of a belt condition.
RECOMMENDATIONS :
Recommend inspecting belt for
proper wear and fit, also inspect sheaves for
wear and replace as needed.
PAGE : 3
C1A
C1R
C1V
C2A
C2R
C2V
M1A
M1R
M1V
M2A
M2R
M2V
9. DATE :
Oct. 27, 2006
COMPANY :
East Hartford
AREA :
Ammonia Room
PRIORITY :
HIGH
PROBLEM STATEMENT :
ENSURE PROPER ELECTRICAL
MACHINE NAME :
#2 Ammonia Compressor
ITEM NUMBER :
MACHINE DRAWING :
FINDINGS :
The Spectrums on the motor
indicates a high 1940 Hz peak with side
bands, which is a indication of a stator
problem.
RECOMMENDATIONS :
Recommend rewinding motor.
PAGE : 9
C1A
C1R
C1V
C2A
C2R
C2V
M1A
M1R
M1V
M2A
M2R
M2V
11. DATE :
June 23, 2005
COMPANY :
ABC Company
AREA :
Line #3
PRIORITY :
CRITICAL
PROBLEM STATEMENT :
ENSURE PROPER UNIT ALIGNMENT
MACHINE NAME :
#3 Can Line
Vacuum Pump
ITEM NUMBER :
MACHINE DRAWING :
FINDINGS :
The Spectrum on the pump indicates
a high 1xfr an 2xfr , which is a indication of
a coupling problem.
RECOMMENDATIONS :
Recommend ensuring proper
coupling wear replace as needed, realign
motor and pump.
PAGE : 12
M1A
M1R
M1V
M2A
M2R
M2V
P1A
P1R
P1V
P2A
P2R
P2V