Cleanrooms Slide 1 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Cleanrooms
Classification, Design and Testing
Ahmadreza Barazesh
Under the supervision of Dr. Vatanara
Cleanrooms Slide 2 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
References
 ISO 14644
– Part 1: Classification of air cleanliness
– Part 2: Continued compliance with
– Part 3: Metrology and test methods
– Part 4: Design, construction and start-up
 WHO Technical Report Series, No. 902, 2002
– Annex 6: Good manufacturing practices for sterile pharmaceutical products
 WHO Technical Report Series, No. 961, 2011
– Annex 5: WHO guidelines on good manufacturing practices for heating, ventilation and air-conditioning systems for
non-sterile pharmaceutical dosage forms
– Annex 6: WHO good manufacturing practices for sterile pharmaceutical products
 PIC/S GMP Guide (Part I: Basic Requirements For Medicinal Products)
 PIC/S Guide To Good Manufacturing Practice For Medicinal Products - Annexes
Disclaimer: The TUMS logo included, neither indicates that the lecturer is an official lecturer of TUMS nor the content
is approved by TUMS. It is just indicative of the department in which the lecture was prepared and presented.
Cleanrooms Slide 3 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Scope
 What will be covered during this presentation:
 A Brief review on cleanroom classification
 Introduction of Design Concepts and Considerations based on ISO
14644 Series Standards, PIC/S and WHO Guidelines.
 Testing Methods and Procedures According to
Cleanrooms Slide 4 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Introduction
 Cleanrooms provide for the control of airborne contamination
to levels appropriate for accomplishing contamination-
sensitive activities.
– Aerospace,
– Microelectronics,
– Pharmaceuticals,
– Medical devices,
– Healthcare (Hospitals)
– Food.
Cleanrooms Slide 5 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Definitions
 Cleanroom: room in which:
– The concentration of airborne particles is controlled,
– Constructed and used in a manner to minimize the introduction, generation,
and retention of particles inside the room,
– Other parameters (temperature, humidity, and pressure) are controlled
 Installation: cleanroom or one or more clean zones, together with all
associated structures, air-treatment systems, services, and utilities.
 Classification: level of airborne particulate cleanliness,
represents maximum allowable concentrations (in particles per
cubic metre of air) for considered sizes of particles
Cleanrooms Slide 6 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Definitions
 Particle: Solid or liquid object which, for purposes of classification of air
cleanliness, falls within a threshold size in the range from 0.1 to 5µm
 Occupancy states
 As-built: installation is complete, all services functioning, no
production equipment, materials, or personnel present
 At-rest: no personnel present
 Operational: the installation is functioning in the specified
manner, specified number of personnel present and working
Cleanrooms Slide 7 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Classification
 The particulate cleanliness of air shall be defined in one or
more of three occupancy states, viz. “as-built”, “at-rest”, or
“operational”
 The maximum permitted concentration of particles, Cn, for
each considered particle size, D,
 In which, N is the ISO classification number, which shall not
exceed a value of 9. (ISO Class 1 to 9)
Cleanrooms Slide 8 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Classification
Cleanrooms Slide 9 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Classification
Graphical representation of ISO-class concentration limits for selected ISO classes
Cleanrooms Slide 10 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Classification
 PIC/S Guide To GMP For Medicinal Products Annex 1
Cleanrooms Slide 11 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Classification
 WHO Technical Report Series, No. 902, 2002 Annex 6
Cleanrooms Slide 12 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Classification
 WHO Technical Report Series, No. 902, 2002 Annex 6
This comparison is defined based on at-rest limitations.
Cleanrooms Slide 13 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Classification
Class
maximum particles/m3
FED STD
209E
equivalent
EU GMP
Classification
≥0.1 µm ≥0.2 µm ≥0.3 µm ≥0.5 µm ≥1 µm ≥5 µm
ISO 1 10 2.37 1.02 0.35 0.083 0.0029
ISO 2 100 23.7 10.2 3.5 0.83 0.029
ISO 3 1,000 237 102 35 8.3 0.29 Class 1
ISO 4 10,000 2,370 1,020 352 83 2.9 Class 10
ISO 5 100,000 23,700 10,200 3,520 832 29 Class 100
Grade A and
Grade B
ISO 6 1.0×106 237,000 102,000 35,200 8,320 293 Class 1,000
ISO 7 1.0×107 2.37×106 1,020,000 352,000 83,200 2,930 Class 10,000 Grade C
ISO 8 1.0×108 2.37×107 1.02×107 3,520,000 832,000 29,300 Class 100,000 Grade D
ISO 9 1.0×109 2.37×108 1.02×108 35,200,000 8,320,000 293,000 Room air
Cleanrooms Slide 14 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Classification
 PIC/S Guide To GMP For Medicinal Products Annex 1
Cleanrooms Slide 15 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Classification: Designation
 The designation of airborne particulate cleanliness for clean rooms and
clean zones shall include:
– the classification number, expressed as “ISO Class N”;
– the occupancy state
– the considered particle size(s), and the concentration(s), 0,1µm through 5 µm.
 Example designation:
– ISO Class 4; operational state; considered sizes: 0,2µm (2 370 particles/m3), 1 µm
(83 particles/m3)
Cleanrooms Slide 16 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
 Airborne particle physical control:
– Filtration (HEPA)
– Dilution (Higher Airchange Rate)
– Isolation HEPA
class
retention (total) retention (local)
E10 > 85% ---
E11 > 95% ---
E12 > 99.5% ---
H13 > 99.95% > 99.75%
H14 > 99.995% > 99.975%
U15 > 99.9995% > 99.9975%
U16 > 99.99995% > 99.99975%
U17 > 99.999995% > 99.9999%
Cleanrooms Slide 17 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Classification: PIC/S
 Grade A: The local zone for high risk operations:
– Filling zone, open ampoules and vials, making aseptic connections.
– Provided by a LAF work station with a homogeneous air speed in a
range of 0.36 – 0.54 m/s (guidance value)
– A unidirectional air flow and lower velocities may be used in closed
isolators and glove boxes.
 Grade B: For aseptic preparation and filling, this is the background
environment for the grade A zone.
 Grade C and D: Clean areas for carrying out less critical stages in the
manufacture of sterile products.
Cleanrooms Slide 18 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
PIC/S General Paragraphs
 Clean Areas:
– Entry through airlocks for personnel and/or for equipment and materials.
– Supplied with air has passed through filters of an appropriate efficiency.
 The various operations of component preparation, product preparation
and filling  in separate areas within the clean area
 Manufacturing operations:
– Product is terminally sterilized,
– Conducted aseptically at some or all stages.
 In order to meet “in operation” conditions, areas should be designed to
reach certain air-cleanliness levels in the “at rest” occupancy state.
Cleanrooms Slide 19 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
PIC/S General Paragraphs
 “In operation” classification may be demonstrated during normal
operations, simulated operations or during media fills (worst-case)
 Clean rooms and clean air devices should be routinely monitored
– Monitoring locations based on risk analysis and the results of classification
– Grade A: full duration of critical processing
– Grade A: Such a frequency and sample size that all interventions, transient
events is captured and alarms triggered
– Grade B: The same as grade A; the sample frequency may be decreased.
– Grade C and D: in accordance with the principles of quality risk management.
Cleanrooms Slide 20 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
PIC/S General Paragraphs
 Terminally Sterilized Products
– Preparation of components and most products should be done in at
least a grade D environment
• Where the product is at a high or unusual risk of microbial contamination 
Grade C
– Filling of products for terminal sterilization  Grade C
• Where the product is at unusual risk of contamination from the environment,
filling  Grade A with Grade C background.
– Preparation and filling of ointments, creams, suspensions and
emulsions should  grade C before terminal sterilization
Cleanrooms Slide 21 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
PIC/S General Paragraphs
 Aseptic Preparation
– Components after washing  Grade D
– Handling of sterile starting materials, unless subjected to
sterilization or filtration  Grade A with Grade B background.
– Otherwise  Grade C
– Handling and filling of aseptically prepared products  Grade A
– Transfer of partially closed containers, as used in freeze drying,
 either in a Grade A environment with grade B background or in
sealed transfer trays in a grade B environment
Cleanrooms Slide 22 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
PIC/S Paragraphs on Premises
 All exposed surfaces should be smooth, impervious and unbroken
 To reduce accumulation of dust and to facilitate cleaning there should
be no uncleanable recesses and a minimum of projecting ledges,
shelves, cupboards and equipment.
 False ceilings should be sealed.
 Sinks and drains should be prohibited in grade A/B areas
 Changing rooms should be designed as airlocks, The final stage of the
changing room should, in the at-rest state, be the same grade as the
area into which it leads.
Cleanrooms Slide 23 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
PIC/S Paragraphs on Premises
 Both airlock doors should not be opened simultaneously; interlocking
system or a visual and/or audible warning system should be operated.
 A filtered air supply should maintain a positive pressure and an air flow
relative to surrounding areas of a lower grade. a pressure differential of
10-15 pascals
 It should be demonstrated that air-flow patterns do not present a
contamination risk.
 A warning system should be provided to indicate failure in the air
supply.
Cleanrooms Slide 24 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Planning and Design
 A project plan shall be developed to define the requirements of the
products, the processes and the scope of the installation.
 A process equipment list shall be compiled, and shall include the critical
requirements for each piece of process equipment.
 Diversity factors shall be defined, considering peak and average
demand for each utility and environmental control system.
 A contamination control concept shall be developed for each zone of an
installation.
Cleanrooms Slide 25 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Design: Control and segregation concepts
 For economic, technical and operational reasons, clean zones are often
enclosed or surrounded by further zones of lower cleanliness.
 The zones with the highest cleanliness demands is reduced to the
minimum size.
 Movement of material and personnel between adjacent clean zones
gives rise to the risk of contamination transfer,
 management of material and personnel flow
Cleanrooms Slide 26 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Design: Control and segregation concepts
Cleanrooms Slide 27 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Design: Personnel flow and Material flow
 Personnel flows considered:
– Manufacturing personnel
– Maintenance personnel
– Quality control personnel
 Material flows considered:
– Raw materials
– Finished goods
– Waste
– Product (In-process, Intermediate & Final)
– Equipment
• Clean and dirty components
• Portable equipment
• Product containers
Cleanrooms Slide 28 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Design: Personnel flow and Material flow
Cleanrooms Slide 29 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Design: Personnel flow and Material flow
Desirable Layout Less Desirable Layout
Cleanrooms Slide 30 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Design: Air Flow Patterns
 Air flow patterns:
– Cleanroom airflow patterns can be categorized as either
unidirectional or non-unidirectional (or mixed)
 Unidirectional airflow
– ISO Class 5 and cleaner
– may be either vertical or horizontal
– airflow rely upon a final filtered air supply and
– return inlets are nearly opposite air supplies to maintain the
airstream straight
Cleanrooms Slide 31 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Design: Air Flow Patterns
 non-unidirectional airflow cleanrooms
– Air flow outlets located in multiple positions. Filter outlets may be
distributed at equal intervals or grouped over the core process.
– The final filter location may be remote, (avoid contamination ingress
between filters and cleanroom)
– Return air locations in non-unidirectional airflows are not as critical
– Distribute the returns to minimize dead zones within the cleanroom
Cleanrooms Slide 32 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Cleanrooms Slide 33 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Disturbance of unidirectional airflow
Cleanrooms Slide 34 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Contamination Control Concepts
Cleanrooms Slide 35 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Cleanrooms Slide 36 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
 In order to protect cleanrooms from contamination from adjacent less
clean spaces
 Displacement concept (low pressure differential, high airflow)
– by means of a low turbulent "displacement" airflow, >0,2 m/s
 Pressure differential concept (high pressure differential, low airflow)
– The pressure differential in the range of
5 - 20 Pa, to allow doors to be opened
and to avoid unintended turbulence.
 Physical barrier concept
– Use of an impervious barrier to prevent contamination transfer to a
clean zone from a less clean zone.
Design: Segregation Concepts
Cleanrooms Slide 37 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Design: Layout of an installation
 General Considerations:
 Size: of cleanroom should be minimum. if a large space is required, it
should be divided, with or without physical barriers.
 Workstation siting and organization: critical workstations away from,
major traffic pathways.
less clean operations site downstream of cleaner operations.
 Ancillary areas and adjacent cleanrooms:
– Pressure or flow differentials,
– Access and communication arrangements
(such as airlocks, speech panels and intercoms
cross-contamination from less
clean zones does not
compromise the cleaner zones.
Cleanrooms Slide 38 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Design: Layout of an installation
 General Considerations (contd.)
 Utility services and ancillary equipment
– General: Utility services should be designed and installed such that
the cleanroom is not compromised by contamination.
– exposed piping, tubing and cable runs should be minimized,
– Vacuum-cleaning equipment
– Sprinkler systems
– Communication systems: to reduce personnel movement
– Glazing: Avoid heat loss and solar gain, non-opening double glaze
Cleanrooms Slide 39 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Design: Layout of an installation
 Access:
 General: The number of openings should be minimized.
Normal (non-emergency) access should be through airlocks for both
personnel and material.
 Airlocks: In order to maintain pressure differential and integrity of
during entry and exit, airlocks or transfer hatches (pass-throughs) are
normally required.
 Emergency exits: Emergency exits should be provided with means
to show that they have been opened.
Cleanrooms Slide 40 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Design: Layout of an installation
 Access (contd.)
 Changing rooms: Have three functional zones:
– Entry: access from ancillary. appropriate for removal, storage,
disposal and/or redonnning of garments not permitted within the
cleanroom;
– Transition zone: where garments or personal equipment dedicated
to the cleanroom are stored, donned or removed.
– Inspection/access zone: where inspection of the completed
gowning is accomplished and provides access to cleanroom.
 The three functional zones may be separated by a physical barrier (e.g.
a stepover bench or airlock)
Cleanrooms Slide 41 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Changing Rooms
Cleanrooms Slide 42 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Design: Layout of an installation
 The following requirements should be defined:
– number of people passing through the gowning procedure
– the gowning procedure (i.e. what garments are to be taken off and put on)
– the frequency of garment replacement.
 Consideration should be given to the following provisions:
– Storage and disposal of garments;
– Storage before use and disposal of consumable items
– Storage of personal items;
– Hand-washing and drying or other decontamination processes;
– Display or posting of gowning sequence, with clear instructions;
– full-length mirrors to check effective fit.
Cleanrooms Slide 43 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Design: Construction and materials
 The materials used should be selected to meet the requirements of the
installation, and should take into account the following:
a) the cleanliness class;
b) effects of abrasion and impact;
c) cleaning and disinfection methods and frequencies;
d) chemical/microbiological attack and corrosion.
 Surface cleanliness and cleanability of materials of construction
 Fittings in airlocks: Minimum horizontal surfaces
Cleanrooms Slide 44 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Design: Construction and materials
 Ceilings: Ceilings should be sealed, penetration points should be kept
minimum.
 Walls: Materials and surface finishes should meet all general requirements.
–Particular consideration to impact and abrasion. (rubbing strips, protective bars)
–Cover strips or seals between panels should be smooth, with rounded edges
–Use double glazing, with airtight seal, which can enable flush mounting
–Doors should present as few horizontal surfaces as possible, thresholds avoided.
–Consider use of push plates, automatic openings, or appropriate door-swing
 Floors: Floors or floor coverings should be non-porous, slip-resistant, abrasion-
resistant, conductive if necessary.
Cleanrooms Slide 45 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Design: Construction and materials
Cleanrooms Slide 46 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Design: Control of air Cleanliness
 Air filtration systems
– Air filtration systems including filter elements, mounting frames,
housings, gaskets, sealants and clamping systems should be
selected to suit both the cleanliness and using condition.
– Three basic stages of air filtration are recommended:
• prefiltering of the outside air to ensure adequate quality of air
supply
• secondary filtering in the air conditioning plant to protect the
final filters;
• final filtering before cleanroom supply.
– “Sacrificial" filters or temporary filters: considered to protect the air
cleanliness of air-handling systems during construction and
commissioning.
Cleanrooms Slide 47 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
HVAC Systems
Cleanrooms Slide 48 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
HVAC Systems
Cleanrooms Slide 49 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
HVAC Systems
Cleanrooms Slide 50 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Tests Methods
 Cleanroom tests:
– Required Tests: An airborne particle count test shall be carried out
in order to classify an installation
– Optional Tests:
• Airborne particle count for ultrafine and/or Micro-particles
• Airflow test
• Air pressure difference tests
• Installed filter system leakage test
• Air flow direction tests and visualization
• Temperature, Humidity and Electrostatic tests
• Particle deposition tests
• Recovery tests
• Containment leak tests
Cleanrooms Slide 51 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Tests Methods
Airborne particle count for classification and test measurement:
 Measurement of airborne particle concentrations with size 0.1 - 5 μm.
 A discrete-particle-counting, light-scattering instrument is used to
determine the concentration of airborne particles.
 Prior to testing, verify that all aspects of the cleanroom and functioning
in accordance with specifications.
– Airflow rate or velocity tests;
– Pressure difference test;
– Containment leakage test;
– Filter leakage test.
Cleanrooms Slide 52 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Airborne particle count for classification and test measurement:
 Sampling
– Minimum number of sampling point locations:
– Sampling locations evenly distributed, at the height of the work activity.
– Sample a sufficient volume of air that a minimum of 20 particles would be
detected if the particle concentration for the largest considered
particle size were at the class limit for the designated ISO class.
– The volume sampled at each location shall be at least 2 litres, with a minimum
sampling time at each location of 1 min.
– Compute the overall mean of the averages, standard deviation, and 95% upper
confidence limit from the average particle concentrations for all locations.
Tests Methods
Cleanrooms Slide 53 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Tests Methods
 Airborne particle count for ultrafine particles
– Smaller than 0,1μm
– DPC, with a capability for accurate particle size definition up to at least 1μm.
– Condensation nucleus counter (CNC)
– Small sampling flow & long sampling tube  diffusion loss.
 Airborne particle count for macro-particles
– Larger than 5 μm.
– There are two general categories of macroparticle measurement methods.
• collection by filtration or inertial effects, followed by microscopic
measurement
• in situ measurement of the concentration and size of macroparticles with a
time-of-flight particle counter or DPC
Cleanrooms Slide 54 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Tests Methods
 Two general categories of macroparticle measurement methods:
– collection by filtration or inertial effects, followed by microscopic measurement of
the number and size, or measurement of the mass of collected particles:
• filter collection and microscopic measurement will report macroparticles
using particle size based upon the agreed diameter;
• cascade impactor collection and microscopic measurement will report
macroparticles using particle size based upon the microscopist's choice of
reported particle diameter;
• cascade impactor collection and weight measurement will report
macroparticles using particle size based upon an aerodynamic diameter;
– In situ measurement of the concentration and size of macroparticles with a time-
of-flight particle counter or a DPC:
• DPC measurement of particle size based upon an equivalent optical
diameter;
• Time-of-flight particle size measurement based upon an aerodynamic
diameter.
Cleanrooms Slide 55 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Tests Methods
Airflow Test
 To measure airflow velocity and uniformity, and supply airflow rate
 Measurement of velocity distribution is necessary in unidirectional airflow
cleanrooms, and supply airflow rate in non-unidirectional cleanrooms.
 Supply airflow rate (air volume supplied to the clean installation per unit
of time) can also be used to determine the air changes.
 Airflow rate is measured either downstream of final filters or in air
supply ducts; both methods rely upon measurement of velocity of air
passing through a known area.
Cleanrooms Slide 56 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Tests Methods: Air Flow Test
Procedure for unidirectional airflow installation test
 Supply airflow velocity
– Measured at approximately 150-300 mm from the filter face.
– Number of measuring points should be the square root of 10 times
of area in m2 but no less than 4. At least 1 point for each filter outlet
 Uniformity of velocity within the cleanroom
– measured at approximately 150-300 mm from the filter face and the
subdivision into grid cells should be defined
 Supply airflow rate measured by filter face velocity
– The results of the airflow velocity test can be used to calculate the
total supply airflow rate.
 Supply airflow rate in air ducts
– by volumetric flowmeters (orifice meters, Venturi meters and anemometers)
Cleanrooms Slide 57 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Tests Methods: Air Flow Test
Procedure for non-unidirectional airflow installation test
 Air volume supply rate and air-change rate are the most important
parameters.
 Supply airflow rate measured at the inlet
– Because of local turbulence, use of a flowhood that captures all of the air
issuing from each supply diffuser is recommended.
 Supply airflow rate calculated from filter face velocity
– Evaluation of the supply airflow rate without a flowhood may be done with
an anemometer downstream of each final filter. The supply airflow rate is
determined from the airflow velocity multiplied by the area of exit.
Cleanrooms Slide 58 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Test Methods
Air pressure difference test
 Verify the capability of the complete installation to maintain the
specified pressure difference between separate spaces
 With all doors closed, the pressure difference between the cleanroom
and any surrounding should be measured and recorded.
 The following should be considered:
– installation of permanent measuring points;
– take measurements near the middle of the cleanroom
away from any supply air inlets or return air outlet.
Cleanrooms Slide 59 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Test Methods
Installed filter system leakage test
 To confirm that the filter system is properly installed and that leaks have
not developed
 Introducing an aerosol challenge upstream of the filters and scanning
immediately downstream of the filters and support frame or by sampling
in a downstream duct.
 Applied to cleanrooms in “as-built” or in “at-rest” occupational states,
and when commissioning new cleanrooms, or existing installations
require re-testing, or after the final filters have been replaced
 Detection of leakage by Scanning / Stationary remeasuring
Cleanrooms Slide 60 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Test Methods: Filter Leakage Test
Cleanrooms Slide 61 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Test Methods
 Apparatus and materials for installed filter system leakage tests
– Aerosol photometer
– Discrete-particle counter (DPC)
– Suitable pneumatic or thermal aerosol generator(s)
– Suitable aerosol dilution system.
– Suitable aerosol source substances
Cleanrooms Slide 62 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Test Methods
Airflow direction test and visualization
 To confirm that the airflow direction and its uniformity conform to the
design and performance specifications
 can be performed by the following four methods:
1. Tracer thread method;
silk threads, single nylon fibers, flags or thin film tapes and effective lighting
2. Tracer injection method;
tracer particles illuminated by high intensity light sources (DI Water ,
alcohol/glycol)
3. Airflow visualization method by image processing techniques; (Quantitative)
4. Airflow visualization method by the measurement of velocity distribution.
Cleanrooms Slide 63 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Test Methods: Air Flow Visualization
Cleanrooms Slide 64 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Test Methods
 Temperature test
– Capability to maintain the air temperature level within the control
– Measured at a minimum of one location for each temperature-
controlled zone.
– Measurement time should be at least 5 min with one value
recorded at least every minute.
– Comprehensive temperature test:
• At least 1 h after the air-conditioning system has been operated
• The number of measuring locations should be at least two.
• Probe should be positioned at work-level height and at a
distance of no less than 300 mm from the ceiling, walls, or floor
of the installation
Cleanrooms Slide 65 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Test Methods
 Humidity test
– Capability to maintain the air humidity level
– Expressed as relative humidity or dew point
– The sensor should be located at least at one location for each
humidity control zone, and sufficient time should be allowed for the
sensor to stabilize.
– The measurement time should be at least 5 min.
Cleanrooms Slide 66 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Test Methods
 Particle deposition test
– Sizing and counting particles that can be deposited from the air
onto product or work surfaces in the installation.
– Particles are collected on witness plates with surface
characteristics similar to those of the at-risk surface
– Are sized and counted using optical microscopes, electron
microscopes, or surface scanning apparatus.
– The witness plate should be placed in the same plane as the at-risk
surface. And at the same electrical potential as the test surface.
Cleanrooms Slide 67 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Test Methods
 Recovery test
– Ability of the installation to eliminate airborne particles.
– Only important and recommended for non-unidirectional airflow
systems
– This test is not recommended for ISO Classes 8 and 9.
– 100:1 recovery time is defined as the time required for decreasing
the initial concentration by a factor of 0,01
Cleanrooms Slide 68 of 68
November 2014
Tehran University of
Medical Sciences
School of Pharmacy
Test Methods
 Containment leak test
– Determine if there is intrusion of contaminated air into the clean
zones from non-controlled areas
– Particle concentration outside should be greater than the
cleanroom concentration by a factor of 103. If the concentration is
less, generate an aerosol.
– To check for leakage through construction joints, cracks or service
conduits, scan inside the enclosure at a distance of not more than 5
cm from the joint, at a scan rate of approximately 5 cm/s.

More Related Content

Similar to Cleanroom Classification, Design and Testing Slideshow

Contamination Control in Cleanrooms_Dr.A. Amsavel
Contamination Control in Cleanrooms_Dr.A. AmsavelContamination Control in Cleanrooms_Dr.A. Amsavel
Contamination Control in Cleanrooms_Dr.A. AmsavelDr. Amsavel A
 
SMALL VOLUME PARENTRALS , MANUFACTURING AND QUALITY CONTROL
SMALL VOLUME PARENTRALS , MANUFACTURING AND QUALITY CONTROLSMALL VOLUME PARENTRALS , MANUFACTURING AND QUALITY CONTROL
SMALL VOLUME PARENTRALS , MANUFACTURING AND QUALITY CONTROLDivya Thakur
 
Sterile Products Manufacturing-EU GMP Annex-1.pptx
Sterile Products Manufacturing-EU GMP Annex-1.pptxSterile Products Manufacturing-EU GMP Annex-1.pptx
Sterile Products Manufacturing-EU GMP Annex-1.pptxObyDulla1
 
Aseptic Technique for sterile area .pptx
Aseptic Technique for sterile area .pptxAseptic Technique for sterile area .pptx
Aseptic Technique for sterile area .pptxNaeemSarwar37
 
Sterile process validation
Sterile process validationSterile process validation
Sterile process validationSagar Savale
 
Advanced sterile product manufacturing technology
Advanced sterile product manufacturing technologyAdvanced sterile product manufacturing technology
Advanced sterile product manufacturing technologyPriyankaSananse
 
MFT Presentation 15 07 2020.pptx
MFT Presentation 15 07 2020.pptxMFT Presentation 15 07 2020.pptx
MFT Presentation 15 07 2020.pptxOwaisAhmed811958
 
The Fundamentals of Cleaning Validation
The Fundamentals of Cleaning ValidationThe Fundamentals of Cleaning Validation
The Fundamentals of Cleaning ValidationSGS
 

Similar to Cleanroom Classification, Design and Testing Slideshow (20)

TRS 961 (2011) - Annex 6 - WHO GMP for sterile pharmaceutical products
TRS 961 (2011) - Annex 6 - WHO GMP for sterile pharmaceutical productsTRS 961 (2011) - Annex 6 - WHO GMP for sterile pharmaceutical products
TRS 961 (2011) - Annex 6 - WHO GMP for sterile pharmaceutical products
 
Solid
SolidSolid
Solid
 
Contamination Control in Cleanrooms_Dr.A. Amsavel
Contamination Control in Cleanrooms_Dr.A. AmsavelContamination Control in Cleanrooms_Dr.A. Amsavel
Contamination Control in Cleanrooms_Dr.A. Amsavel
 
WHO_Sterile Products.ppt
WHO_Sterile Products.pptWHO_Sterile Products.ppt
WHO_Sterile Products.ppt
 
Gmp premicses
Gmp premicses Gmp premicses
Gmp premicses
 
SMALL VOLUME PARENTRALS , MANUFACTURING AND QUALITY CONTROL
SMALL VOLUME PARENTRALS , MANUFACTURING AND QUALITY CONTROLSMALL VOLUME PARENTRALS , MANUFACTURING AND QUALITY CONTROL
SMALL VOLUME PARENTRALS , MANUFACTURING AND QUALITY CONTROL
 
Sterile Products Manufacturing-EU GMP Annex-1.pptx
Sterile Products Manufacturing-EU GMP Annex-1.pptxSterile Products Manufacturing-EU GMP Annex-1.pptx
Sterile Products Manufacturing-EU GMP Annex-1.pptx
 
Aseptic Technique for sterile area .pptx
Aseptic Technique for sterile area .pptxAseptic Technique for sterile area .pptx
Aseptic Technique for sterile area .pptx
 
M03_A(1).ppt
M03_A(1).pptM03_A(1).ppt
M03_A(1).ppt
 
Sterile process validation
Sterile process validationSterile process validation
Sterile process validation
 
HVAC system
 HVAC system HVAC system
HVAC system
 
Asean tmhs-gmp-training-chapter-3-premises-and-equipment-21-nov-2016
Asean tmhs-gmp-training-chapter-3-premises-and-equipment-21-nov-2016Asean tmhs-gmp-training-chapter-3-premises-and-equipment-21-nov-2016
Asean tmhs-gmp-training-chapter-3-premises-and-equipment-21-nov-2016
 
Advanced sterile product manufacturing technology
Advanced sterile product manufacturing technologyAdvanced sterile product manufacturing technology
Advanced sterile product manufacturing technology
 
Environmental monitoring
Environmental monitoringEnvironmental monitoring
Environmental monitoring
 
Presentation22.ppt
Presentation22.pptPresentation22.ppt
Presentation22.ppt
 
EU GMP Revise.pdf
EU GMP Revise.pdfEU GMP Revise.pdf
EU GMP Revise.pdf
 
MFT Presentation 15 07 2020.pptx
MFT Presentation 15 07 2020.pptxMFT Presentation 15 07 2020.pptx
MFT Presentation 15 07 2020.pptx
 
Gmp ppt
Gmp pptGmp ppt
Gmp ppt
 
Royal Link Pharma
Royal Link PharmaRoyal Link Pharma
Royal Link Pharma
 
The Fundamentals of Cleaning Validation
The Fundamentals of Cleaning ValidationThe Fundamentals of Cleaning Validation
The Fundamentals of Cleaning Validation
 

Recently uploaded

Cheap Rate Call girls Kalkaji 9205541914 shot 1500 night
Cheap Rate Call girls Kalkaji 9205541914 shot 1500 nightCheap Rate Call girls Kalkaji 9205541914 shot 1500 night
Cheap Rate Call girls Kalkaji 9205541914 shot 1500 nightDelhi Call girls
 
SCRIP Lua HTTP PROGRACMACION PLC WECON CA
SCRIP Lua HTTP PROGRACMACION PLC  WECON CASCRIP Lua HTTP PROGRACMACION PLC  WECON CA
SCRIP Lua HTTP PROGRACMACION PLC WECON CANestorGamez6
 
MASONRY -Building Technology and Construction
MASONRY -Building Technology and ConstructionMASONRY -Building Technology and Construction
MASONRY -Building Technology and Constructionmbermudez3
 
Best VIP Call Girls Noida Sector 44 Call Me: 8448380779
Best VIP Call Girls Noida Sector 44 Call Me: 8448380779Best VIP Call Girls Noida Sector 44 Call Me: 8448380779
Best VIP Call Girls Noida Sector 44 Call Me: 8448380779Delhi Call girls
 
VIP Russian Call Girls in Gorakhpur Deepika 8250192130 Independent Escort Ser...
VIP Russian Call Girls in Gorakhpur Deepika 8250192130 Independent Escort Ser...VIP Russian Call Girls in Gorakhpur Deepika 8250192130 Independent Escort Ser...
VIP Russian Call Girls in Gorakhpur Deepika 8250192130 Independent Escort Ser...Suhani Kapoor
 
Raj Nagar Extension Call Girls 9711199012 WhatsApp No, Delhi Escorts in Raj N...
Raj Nagar Extension Call Girls 9711199012 WhatsApp No, Delhi Escorts in Raj N...Raj Nagar Extension Call Girls 9711199012 WhatsApp No, Delhi Escorts in Raj N...
Raj Nagar Extension Call Girls 9711199012 WhatsApp No, Delhi Escorts in Raj N...ankitnayak356677
 
VVIP Pune Call Girls Hadapsar (7001035870) Pune Escorts Nearby with Complete ...
VVIP Pune Call Girls Hadapsar (7001035870) Pune Escorts Nearby with Complete ...VVIP Pune Call Girls Hadapsar (7001035870) Pune Escorts Nearby with Complete ...
VVIP Pune Call Girls Hadapsar (7001035870) Pune Escorts Nearby with Complete ...Call Girls in Nagpur High Profile
 
VIP Call Girls Bhiwandi Ananya 8250192130 Independent Escort Service Bhiwandi
VIP Call Girls Bhiwandi Ananya 8250192130 Independent Escort Service BhiwandiVIP Call Girls Bhiwandi Ananya 8250192130 Independent Escort Service Bhiwandi
VIP Call Girls Bhiwandi Ananya 8250192130 Independent Escort Service BhiwandiSuhani Kapoor
 
call girls in Harsh Vihar (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️
call girls in Harsh Vihar (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️call girls in Harsh Vihar (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️
call girls in Harsh Vihar (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️9953056974 Low Rate Call Girls In Saket, Delhi NCR
 
Call Girls In Safdarjung Enclave 24/7✡️9711147426✡️ Escorts Service
Call Girls In Safdarjung Enclave 24/7✡️9711147426✡️ Escorts ServiceCall Girls In Safdarjung Enclave 24/7✡️9711147426✡️ Escorts Service
Call Girls In Safdarjung Enclave 24/7✡️9711147426✡️ Escorts Servicejennyeacort
 
Recommendable # 971589162217 # philippine Young Call Girls in Dubai By Marina...
Recommendable # 971589162217 # philippine Young Call Girls in Dubai By Marina...Recommendable # 971589162217 # philippine Young Call Girls in Dubai By Marina...
Recommendable # 971589162217 # philippine Young Call Girls in Dubai By Marina...home
 
Revit Understanding Reference Planes and Reference lines in Revit for Family ...
Revit Understanding Reference Planes and Reference lines in Revit for Family ...Revit Understanding Reference Planes and Reference lines in Revit for Family ...
Revit Understanding Reference Planes and Reference lines in Revit for Family ...Narsimha murthy
 
Chapter 19_DDA_TOD Policy_First Draft 2012.pdf
Chapter 19_DDA_TOD Policy_First Draft 2012.pdfChapter 19_DDA_TOD Policy_First Draft 2012.pdf
Chapter 19_DDA_TOD Policy_First Draft 2012.pdfParomita Roy
 
Captivating Charm: Exploring Marseille's Hillside Villas with Our 3D Architec...
Captivating Charm: Exploring Marseille's Hillside Villas with Our 3D Architec...Captivating Charm: Exploring Marseille's Hillside Villas with Our 3D Architec...
Captivating Charm: Exploring Marseille's Hillside Villas with Our 3D Architec...Yantram Animation Studio Corporation
 
Design Portfolio - 2024 - William Vickery
Design Portfolio - 2024 - William VickeryDesign Portfolio - 2024 - William Vickery
Design Portfolio - 2024 - William VickeryWilliamVickery6
 
SD_The MATATAG Curriculum Training Design.pptx
SD_The MATATAG Curriculum Training Design.pptxSD_The MATATAG Curriculum Training Design.pptx
SD_The MATATAG Curriculum Training Design.pptxjanettecruzeiro1
 
VIP Call Girls Service Mehdipatnam Hyderabad Call +91-8250192130
VIP Call Girls Service Mehdipatnam Hyderabad Call +91-8250192130VIP Call Girls Service Mehdipatnam Hyderabad Call +91-8250192130
VIP Call Girls Service Mehdipatnam Hyderabad Call +91-8250192130Suhani Kapoor
 
A level Digipak development Presentation
A level Digipak development PresentationA level Digipak development Presentation
A level Digipak development Presentationamedia6
 
VIP Call Girl Amravati Aashi 8250192130 Independent Escort Service Amravati
VIP Call Girl Amravati Aashi 8250192130 Independent Escort Service AmravatiVIP Call Girl Amravati Aashi 8250192130 Independent Escort Service Amravati
VIP Call Girl Amravati Aashi 8250192130 Independent Escort Service AmravatiSuhani Kapoor
 

Recently uploaded (20)

Cheap Rate Call girls Kalkaji 9205541914 shot 1500 night
Cheap Rate Call girls Kalkaji 9205541914 shot 1500 nightCheap Rate Call girls Kalkaji 9205541914 shot 1500 night
Cheap Rate Call girls Kalkaji 9205541914 shot 1500 night
 
SCRIP Lua HTTP PROGRACMACION PLC WECON CA
SCRIP Lua HTTP PROGRACMACION PLC  WECON CASCRIP Lua HTTP PROGRACMACION PLC  WECON CA
SCRIP Lua HTTP PROGRACMACION PLC WECON CA
 
young call girls in Vivek Vihar🔝 9953056974 🔝 Delhi escort Service
young call girls in Vivek Vihar🔝 9953056974 🔝 Delhi escort Serviceyoung call girls in Vivek Vihar🔝 9953056974 🔝 Delhi escort Service
young call girls in Vivek Vihar🔝 9953056974 🔝 Delhi escort Service
 
MASONRY -Building Technology and Construction
MASONRY -Building Technology and ConstructionMASONRY -Building Technology and Construction
MASONRY -Building Technology and Construction
 
Best VIP Call Girls Noida Sector 44 Call Me: 8448380779
Best VIP Call Girls Noida Sector 44 Call Me: 8448380779Best VIP Call Girls Noida Sector 44 Call Me: 8448380779
Best VIP Call Girls Noida Sector 44 Call Me: 8448380779
 
VIP Russian Call Girls in Gorakhpur Deepika 8250192130 Independent Escort Ser...
VIP Russian Call Girls in Gorakhpur Deepika 8250192130 Independent Escort Ser...VIP Russian Call Girls in Gorakhpur Deepika 8250192130 Independent Escort Ser...
VIP Russian Call Girls in Gorakhpur Deepika 8250192130 Independent Escort Ser...
 
Raj Nagar Extension Call Girls 9711199012 WhatsApp No, Delhi Escorts in Raj N...
Raj Nagar Extension Call Girls 9711199012 WhatsApp No, Delhi Escorts in Raj N...Raj Nagar Extension Call Girls 9711199012 WhatsApp No, Delhi Escorts in Raj N...
Raj Nagar Extension Call Girls 9711199012 WhatsApp No, Delhi Escorts in Raj N...
 
VVIP Pune Call Girls Hadapsar (7001035870) Pune Escorts Nearby with Complete ...
VVIP Pune Call Girls Hadapsar (7001035870) Pune Escorts Nearby with Complete ...VVIP Pune Call Girls Hadapsar (7001035870) Pune Escorts Nearby with Complete ...
VVIP Pune Call Girls Hadapsar (7001035870) Pune Escorts Nearby with Complete ...
 
VIP Call Girls Bhiwandi Ananya 8250192130 Independent Escort Service Bhiwandi
VIP Call Girls Bhiwandi Ananya 8250192130 Independent Escort Service BhiwandiVIP Call Girls Bhiwandi Ananya 8250192130 Independent Escort Service Bhiwandi
VIP Call Girls Bhiwandi Ananya 8250192130 Independent Escort Service Bhiwandi
 
call girls in Harsh Vihar (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️
call girls in Harsh Vihar (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️call girls in Harsh Vihar (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️
call girls in Harsh Vihar (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️
 
Call Girls In Safdarjung Enclave 24/7✡️9711147426✡️ Escorts Service
Call Girls In Safdarjung Enclave 24/7✡️9711147426✡️ Escorts ServiceCall Girls In Safdarjung Enclave 24/7✡️9711147426✡️ Escorts Service
Call Girls In Safdarjung Enclave 24/7✡️9711147426✡️ Escorts Service
 
Recommendable # 971589162217 # philippine Young Call Girls in Dubai By Marina...
Recommendable # 971589162217 # philippine Young Call Girls in Dubai By Marina...Recommendable # 971589162217 # philippine Young Call Girls in Dubai By Marina...
Recommendable # 971589162217 # philippine Young Call Girls in Dubai By Marina...
 
Revit Understanding Reference Planes and Reference lines in Revit for Family ...
Revit Understanding Reference Planes and Reference lines in Revit for Family ...Revit Understanding Reference Planes and Reference lines in Revit for Family ...
Revit Understanding Reference Planes and Reference lines in Revit for Family ...
 
Chapter 19_DDA_TOD Policy_First Draft 2012.pdf
Chapter 19_DDA_TOD Policy_First Draft 2012.pdfChapter 19_DDA_TOD Policy_First Draft 2012.pdf
Chapter 19_DDA_TOD Policy_First Draft 2012.pdf
 
Captivating Charm: Exploring Marseille's Hillside Villas with Our 3D Architec...
Captivating Charm: Exploring Marseille's Hillside Villas with Our 3D Architec...Captivating Charm: Exploring Marseille's Hillside Villas with Our 3D Architec...
Captivating Charm: Exploring Marseille's Hillside Villas with Our 3D Architec...
 
Design Portfolio - 2024 - William Vickery
Design Portfolio - 2024 - William VickeryDesign Portfolio - 2024 - William Vickery
Design Portfolio - 2024 - William Vickery
 
SD_The MATATAG Curriculum Training Design.pptx
SD_The MATATAG Curriculum Training Design.pptxSD_The MATATAG Curriculum Training Design.pptx
SD_The MATATAG Curriculum Training Design.pptx
 
VIP Call Girls Service Mehdipatnam Hyderabad Call +91-8250192130
VIP Call Girls Service Mehdipatnam Hyderabad Call +91-8250192130VIP Call Girls Service Mehdipatnam Hyderabad Call +91-8250192130
VIP Call Girls Service Mehdipatnam Hyderabad Call +91-8250192130
 
A level Digipak development Presentation
A level Digipak development PresentationA level Digipak development Presentation
A level Digipak development Presentation
 
VIP Call Girl Amravati Aashi 8250192130 Independent Escort Service Amravati
VIP Call Girl Amravati Aashi 8250192130 Independent Escort Service AmravatiVIP Call Girl Amravati Aashi 8250192130 Independent Escort Service Amravati
VIP Call Girl Amravati Aashi 8250192130 Independent Escort Service Amravati
 

Cleanroom Classification, Design and Testing Slideshow

  • 1. Cleanrooms Slide 1 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Cleanrooms Classification, Design and Testing Ahmadreza Barazesh Under the supervision of Dr. Vatanara
  • 2. Cleanrooms Slide 2 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy References  ISO 14644 – Part 1: Classification of air cleanliness – Part 2: Continued compliance with – Part 3: Metrology and test methods – Part 4: Design, construction and start-up  WHO Technical Report Series, No. 902, 2002 – Annex 6: Good manufacturing practices for sterile pharmaceutical products  WHO Technical Report Series, No. 961, 2011 – Annex 5: WHO guidelines on good manufacturing practices for heating, ventilation and air-conditioning systems for non-sterile pharmaceutical dosage forms – Annex 6: WHO good manufacturing practices for sterile pharmaceutical products  PIC/S GMP Guide (Part I: Basic Requirements For Medicinal Products)  PIC/S Guide To Good Manufacturing Practice For Medicinal Products - Annexes Disclaimer: The TUMS logo included, neither indicates that the lecturer is an official lecturer of TUMS nor the content is approved by TUMS. It is just indicative of the department in which the lecture was prepared and presented.
  • 3. Cleanrooms Slide 3 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Scope  What will be covered during this presentation:  A Brief review on cleanroom classification  Introduction of Design Concepts and Considerations based on ISO 14644 Series Standards, PIC/S and WHO Guidelines.  Testing Methods and Procedures According to
  • 4. Cleanrooms Slide 4 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Introduction  Cleanrooms provide for the control of airborne contamination to levels appropriate for accomplishing contamination- sensitive activities. – Aerospace, – Microelectronics, – Pharmaceuticals, – Medical devices, – Healthcare (Hospitals) – Food.
  • 5. Cleanrooms Slide 5 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Definitions  Cleanroom: room in which: – The concentration of airborne particles is controlled, – Constructed and used in a manner to minimize the introduction, generation, and retention of particles inside the room, – Other parameters (temperature, humidity, and pressure) are controlled  Installation: cleanroom or one or more clean zones, together with all associated structures, air-treatment systems, services, and utilities.  Classification: level of airborne particulate cleanliness, represents maximum allowable concentrations (in particles per cubic metre of air) for considered sizes of particles
  • 6. Cleanrooms Slide 6 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Definitions  Particle: Solid or liquid object which, for purposes of classification of air cleanliness, falls within a threshold size in the range from 0.1 to 5µm  Occupancy states  As-built: installation is complete, all services functioning, no production equipment, materials, or personnel present  At-rest: no personnel present  Operational: the installation is functioning in the specified manner, specified number of personnel present and working
  • 7. Cleanrooms Slide 7 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Classification  The particulate cleanliness of air shall be defined in one or more of three occupancy states, viz. “as-built”, “at-rest”, or “operational”  The maximum permitted concentration of particles, Cn, for each considered particle size, D,  In which, N is the ISO classification number, which shall not exceed a value of 9. (ISO Class 1 to 9)
  • 8. Cleanrooms Slide 8 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Classification
  • 9. Cleanrooms Slide 9 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Classification Graphical representation of ISO-class concentration limits for selected ISO classes
  • 10. Cleanrooms Slide 10 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Classification  PIC/S Guide To GMP For Medicinal Products Annex 1
  • 11. Cleanrooms Slide 11 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Classification  WHO Technical Report Series, No. 902, 2002 Annex 6
  • 12. Cleanrooms Slide 12 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Classification  WHO Technical Report Series, No. 902, 2002 Annex 6 This comparison is defined based on at-rest limitations.
  • 13. Cleanrooms Slide 13 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Classification Class maximum particles/m3 FED STD 209E equivalent EU GMP Classification ≥0.1 µm ≥0.2 µm ≥0.3 µm ≥0.5 µm ≥1 µm ≥5 µm ISO 1 10 2.37 1.02 0.35 0.083 0.0029 ISO 2 100 23.7 10.2 3.5 0.83 0.029 ISO 3 1,000 237 102 35 8.3 0.29 Class 1 ISO 4 10,000 2,370 1,020 352 83 2.9 Class 10 ISO 5 100,000 23,700 10,200 3,520 832 29 Class 100 Grade A and Grade B ISO 6 1.0×106 237,000 102,000 35,200 8,320 293 Class 1,000 ISO 7 1.0×107 2.37×106 1,020,000 352,000 83,200 2,930 Class 10,000 Grade C ISO 8 1.0×108 2.37×107 1.02×107 3,520,000 832,000 29,300 Class 100,000 Grade D ISO 9 1.0×109 2.37×108 1.02×108 35,200,000 8,320,000 293,000 Room air
  • 14. Cleanrooms Slide 14 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Classification  PIC/S Guide To GMP For Medicinal Products Annex 1
  • 15. Cleanrooms Slide 15 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Classification: Designation  The designation of airborne particulate cleanliness for clean rooms and clean zones shall include: – the classification number, expressed as “ISO Class N”; – the occupancy state – the considered particle size(s), and the concentration(s), 0,1µm through 5 µm.  Example designation: – ISO Class 4; operational state; considered sizes: 0,2µm (2 370 particles/m3), 1 µm (83 particles/m3)
  • 16. Cleanrooms Slide 16 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy  Airborne particle physical control: – Filtration (HEPA) – Dilution (Higher Airchange Rate) – Isolation HEPA class retention (total) retention (local) E10 > 85% --- E11 > 95% --- E12 > 99.5% --- H13 > 99.95% > 99.75% H14 > 99.995% > 99.975% U15 > 99.9995% > 99.9975% U16 > 99.99995% > 99.99975% U17 > 99.999995% > 99.9999%
  • 17. Cleanrooms Slide 17 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Classification: PIC/S  Grade A: The local zone for high risk operations: – Filling zone, open ampoules and vials, making aseptic connections. – Provided by a LAF work station with a homogeneous air speed in a range of 0.36 – 0.54 m/s (guidance value) – A unidirectional air flow and lower velocities may be used in closed isolators and glove boxes.  Grade B: For aseptic preparation and filling, this is the background environment for the grade A zone.  Grade C and D: Clean areas for carrying out less critical stages in the manufacture of sterile products.
  • 18. Cleanrooms Slide 18 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy PIC/S General Paragraphs  Clean Areas: – Entry through airlocks for personnel and/or for equipment and materials. – Supplied with air has passed through filters of an appropriate efficiency.  The various operations of component preparation, product preparation and filling  in separate areas within the clean area  Manufacturing operations: – Product is terminally sterilized, – Conducted aseptically at some or all stages.  In order to meet “in operation” conditions, areas should be designed to reach certain air-cleanliness levels in the “at rest” occupancy state.
  • 19. Cleanrooms Slide 19 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy PIC/S General Paragraphs  “In operation” classification may be demonstrated during normal operations, simulated operations or during media fills (worst-case)  Clean rooms and clean air devices should be routinely monitored – Monitoring locations based on risk analysis and the results of classification – Grade A: full duration of critical processing – Grade A: Such a frequency and sample size that all interventions, transient events is captured and alarms triggered – Grade B: The same as grade A; the sample frequency may be decreased. – Grade C and D: in accordance with the principles of quality risk management.
  • 20. Cleanrooms Slide 20 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy PIC/S General Paragraphs  Terminally Sterilized Products – Preparation of components and most products should be done in at least a grade D environment • Where the product is at a high or unusual risk of microbial contamination  Grade C – Filling of products for terminal sterilization  Grade C • Where the product is at unusual risk of contamination from the environment, filling  Grade A with Grade C background. – Preparation and filling of ointments, creams, suspensions and emulsions should  grade C before terminal sterilization
  • 21. Cleanrooms Slide 21 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy PIC/S General Paragraphs  Aseptic Preparation – Components after washing  Grade D – Handling of sterile starting materials, unless subjected to sterilization or filtration  Grade A with Grade B background. – Otherwise  Grade C – Handling and filling of aseptically prepared products  Grade A – Transfer of partially closed containers, as used in freeze drying,  either in a Grade A environment with grade B background or in sealed transfer trays in a grade B environment
  • 22. Cleanrooms Slide 22 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy PIC/S Paragraphs on Premises  All exposed surfaces should be smooth, impervious and unbroken  To reduce accumulation of dust and to facilitate cleaning there should be no uncleanable recesses and a minimum of projecting ledges, shelves, cupboards and equipment.  False ceilings should be sealed.  Sinks and drains should be prohibited in grade A/B areas  Changing rooms should be designed as airlocks, The final stage of the changing room should, in the at-rest state, be the same grade as the area into which it leads.
  • 23. Cleanrooms Slide 23 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy PIC/S Paragraphs on Premises  Both airlock doors should not be opened simultaneously; interlocking system or a visual and/or audible warning system should be operated.  A filtered air supply should maintain a positive pressure and an air flow relative to surrounding areas of a lower grade. a pressure differential of 10-15 pascals  It should be demonstrated that air-flow patterns do not present a contamination risk.  A warning system should be provided to indicate failure in the air supply.
  • 24. Cleanrooms Slide 24 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Planning and Design  A project plan shall be developed to define the requirements of the products, the processes and the scope of the installation.  A process equipment list shall be compiled, and shall include the critical requirements for each piece of process equipment.  Diversity factors shall be defined, considering peak and average demand for each utility and environmental control system.  A contamination control concept shall be developed for each zone of an installation.
  • 25. Cleanrooms Slide 25 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Design: Control and segregation concepts  For economic, technical and operational reasons, clean zones are often enclosed or surrounded by further zones of lower cleanliness.  The zones with the highest cleanliness demands is reduced to the minimum size.  Movement of material and personnel between adjacent clean zones gives rise to the risk of contamination transfer,  management of material and personnel flow
  • 26. Cleanrooms Slide 26 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Design: Control and segregation concepts
  • 27. Cleanrooms Slide 27 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Design: Personnel flow and Material flow  Personnel flows considered: – Manufacturing personnel – Maintenance personnel – Quality control personnel  Material flows considered: – Raw materials – Finished goods – Waste – Product (In-process, Intermediate & Final) – Equipment • Clean and dirty components • Portable equipment • Product containers
  • 28. Cleanrooms Slide 28 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Design: Personnel flow and Material flow
  • 29. Cleanrooms Slide 29 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Design: Personnel flow and Material flow Desirable Layout Less Desirable Layout
  • 30. Cleanrooms Slide 30 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Design: Air Flow Patterns  Air flow patterns: – Cleanroom airflow patterns can be categorized as either unidirectional or non-unidirectional (or mixed)  Unidirectional airflow – ISO Class 5 and cleaner – may be either vertical or horizontal – airflow rely upon a final filtered air supply and – return inlets are nearly opposite air supplies to maintain the airstream straight
  • 31. Cleanrooms Slide 31 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Design: Air Flow Patterns  non-unidirectional airflow cleanrooms – Air flow outlets located in multiple positions. Filter outlets may be distributed at equal intervals or grouped over the core process. – The final filter location may be remote, (avoid contamination ingress between filters and cleanroom) – Return air locations in non-unidirectional airflows are not as critical – Distribute the returns to minimize dead zones within the cleanroom
  • 32. Cleanrooms Slide 32 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy
  • 33. Cleanrooms Slide 33 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Disturbance of unidirectional airflow
  • 34. Cleanrooms Slide 34 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Contamination Control Concepts
  • 35. Cleanrooms Slide 35 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy
  • 36. Cleanrooms Slide 36 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy  In order to protect cleanrooms from contamination from adjacent less clean spaces  Displacement concept (low pressure differential, high airflow) – by means of a low turbulent "displacement" airflow, >0,2 m/s  Pressure differential concept (high pressure differential, low airflow) – The pressure differential in the range of 5 - 20 Pa, to allow doors to be opened and to avoid unintended turbulence.  Physical barrier concept – Use of an impervious barrier to prevent contamination transfer to a clean zone from a less clean zone. Design: Segregation Concepts
  • 37. Cleanrooms Slide 37 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Design: Layout of an installation  General Considerations:  Size: of cleanroom should be minimum. if a large space is required, it should be divided, with or without physical barriers.  Workstation siting and organization: critical workstations away from, major traffic pathways. less clean operations site downstream of cleaner operations.  Ancillary areas and adjacent cleanrooms: – Pressure or flow differentials, – Access and communication arrangements (such as airlocks, speech panels and intercoms cross-contamination from less clean zones does not compromise the cleaner zones.
  • 38. Cleanrooms Slide 38 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Design: Layout of an installation  General Considerations (contd.)  Utility services and ancillary equipment – General: Utility services should be designed and installed such that the cleanroom is not compromised by contamination. – exposed piping, tubing and cable runs should be minimized, – Vacuum-cleaning equipment – Sprinkler systems – Communication systems: to reduce personnel movement – Glazing: Avoid heat loss and solar gain, non-opening double glaze
  • 39. Cleanrooms Slide 39 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Design: Layout of an installation  Access:  General: The number of openings should be minimized. Normal (non-emergency) access should be through airlocks for both personnel and material.  Airlocks: In order to maintain pressure differential and integrity of during entry and exit, airlocks or transfer hatches (pass-throughs) are normally required.  Emergency exits: Emergency exits should be provided with means to show that they have been opened.
  • 40. Cleanrooms Slide 40 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Design: Layout of an installation  Access (contd.)  Changing rooms: Have three functional zones: – Entry: access from ancillary. appropriate for removal, storage, disposal and/or redonnning of garments not permitted within the cleanroom; – Transition zone: where garments or personal equipment dedicated to the cleanroom are stored, donned or removed. – Inspection/access zone: where inspection of the completed gowning is accomplished and provides access to cleanroom.  The three functional zones may be separated by a physical barrier (e.g. a stepover bench or airlock)
  • 41. Cleanrooms Slide 41 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Changing Rooms
  • 42. Cleanrooms Slide 42 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Design: Layout of an installation  The following requirements should be defined: – number of people passing through the gowning procedure – the gowning procedure (i.e. what garments are to be taken off and put on) – the frequency of garment replacement.  Consideration should be given to the following provisions: – Storage and disposal of garments; – Storage before use and disposal of consumable items – Storage of personal items; – Hand-washing and drying or other decontamination processes; – Display or posting of gowning sequence, with clear instructions; – full-length mirrors to check effective fit.
  • 43. Cleanrooms Slide 43 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Design: Construction and materials  The materials used should be selected to meet the requirements of the installation, and should take into account the following: a) the cleanliness class; b) effects of abrasion and impact; c) cleaning and disinfection methods and frequencies; d) chemical/microbiological attack and corrosion.  Surface cleanliness and cleanability of materials of construction  Fittings in airlocks: Minimum horizontal surfaces
  • 44. Cleanrooms Slide 44 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Design: Construction and materials  Ceilings: Ceilings should be sealed, penetration points should be kept minimum.  Walls: Materials and surface finishes should meet all general requirements. –Particular consideration to impact and abrasion. (rubbing strips, protective bars) –Cover strips or seals between panels should be smooth, with rounded edges –Use double glazing, with airtight seal, which can enable flush mounting –Doors should present as few horizontal surfaces as possible, thresholds avoided. –Consider use of push plates, automatic openings, or appropriate door-swing  Floors: Floors or floor coverings should be non-porous, slip-resistant, abrasion- resistant, conductive if necessary.
  • 45. Cleanrooms Slide 45 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Design: Construction and materials
  • 46. Cleanrooms Slide 46 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Design: Control of air Cleanliness  Air filtration systems – Air filtration systems including filter elements, mounting frames, housings, gaskets, sealants and clamping systems should be selected to suit both the cleanliness and using condition. – Three basic stages of air filtration are recommended: • prefiltering of the outside air to ensure adequate quality of air supply • secondary filtering in the air conditioning plant to protect the final filters; • final filtering before cleanroom supply. – “Sacrificial" filters or temporary filters: considered to protect the air cleanliness of air-handling systems during construction and commissioning.
  • 47. Cleanrooms Slide 47 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy HVAC Systems
  • 48. Cleanrooms Slide 48 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy HVAC Systems
  • 49. Cleanrooms Slide 49 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy HVAC Systems
  • 50. Cleanrooms Slide 50 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Tests Methods  Cleanroom tests: – Required Tests: An airborne particle count test shall be carried out in order to classify an installation – Optional Tests: • Airborne particle count for ultrafine and/or Micro-particles • Airflow test • Air pressure difference tests • Installed filter system leakage test • Air flow direction tests and visualization • Temperature, Humidity and Electrostatic tests • Particle deposition tests • Recovery tests • Containment leak tests
  • 51. Cleanrooms Slide 51 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Tests Methods Airborne particle count for classification and test measurement:  Measurement of airborne particle concentrations with size 0.1 - 5 μm.  A discrete-particle-counting, light-scattering instrument is used to determine the concentration of airborne particles.  Prior to testing, verify that all aspects of the cleanroom and functioning in accordance with specifications. – Airflow rate or velocity tests; – Pressure difference test; – Containment leakage test; – Filter leakage test.
  • 52. Cleanrooms Slide 52 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Airborne particle count for classification and test measurement:  Sampling – Minimum number of sampling point locations: – Sampling locations evenly distributed, at the height of the work activity. – Sample a sufficient volume of air that a minimum of 20 particles would be detected if the particle concentration for the largest considered particle size were at the class limit for the designated ISO class. – The volume sampled at each location shall be at least 2 litres, with a minimum sampling time at each location of 1 min. – Compute the overall mean of the averages, standard deviation, and 95% upper confidence limit from the average particle concentrations for all locations. Tests Methods
  • 53. Cleanrooms Slide 53 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Tests Methods  Airborne particle count for ultrafine particles – Smaller than 0,1μm – DPC, with a capability for accurate particle size definition up to at least 1μm. – Condensation nucleus counter (CNC) – Small sampling flow & long sampling tube  diffusion loss.  Airborne particle count for macro-particles – Larger than 5 μm. – There are two general categories of macroparticle measurement methods. • collection by filtration or inertial effects, followed by microscopic measurement • in situ measurement of the concentration and size of macroparticles with a time-of-flight particle counter or DPC
  • 54. Cleanrooms Slide 54 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Tests Methods  Two general categories of macroparticle measurement methods: – collection by filtration or inertial effects, followed by microscopic measurement of the number and size, or measurement of the mass of collected particles: • filter collection and microscopic measurement will report macroparticles using particle size based upon the agreed diameter; • cascade impactor collection and microscopic measurement will report macroparticles using particle size based upon the microscopist's choice of reported particle diameter; • cascade impactor collection and weight measurement will report macroparticles using particle size based upon an aerodynamic diameter; – In situ measurement of the concentration and size of macroparticles with a time- of-flight particle counter or a DPC: • DPC measurement of particle size based upon an equivalent optical diameter; • Time-of-flight particle size measurement based upon an aerodynamic diameter.
  • 55. Cleanrooms Slide 55 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Tests Methods Airflow Test  To measure airflow velocity and uniformity, and supply airflow rate  Measurement of velocity distribution is necessary in unidirectional airflow cleanrooms, and supply airflow rate in non-unidirectional cleanrooms.  Supply airflow rate (air volume supplied to the clean installation per unit of time) can also be used to determine the air changes.  Airflow rate is measured either downstream of final filters or in air supply ducts; both methods rely upon measurement of velocity of air passing through a known area.
  • 56. Cleanrooms Slide 56 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Tests Methods: Air Flow Test Procedure for unidirectional airflow installation test  Supply airflow velocity – Measured at approximately 150-300 mm from the filter face. – Number of measuring points should be the square root of 10 times of area in m2 but no less than 4. At least 1 point for each filter outlet  Uniformity of velocity within the cleanroom – measured at approximately 150-300 mm from the filter face and the subdivision into grid cells should be defined  Supply airflow rate measured by filter face velocity – The results of the airflow velocity test can be used to calculate the total supply airflow rate.  Supply airflow rate in air ducts – by volumetric flowmeters (orifice meters, Venturi meters and anemometers)
  • 57. Cleanrooms Slide 57 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Tests Methods: Air Flow Test Procedure for non-unidirectional airflow installation test  Air volume supply rate and air-change rate are the most important parameters.  Supply airflow rate measured at the inlet – Because of local turbulence, use of a flowhood that captures all of the air issuing from each supply diffuser is recommended.  Supply airflow rate calculated from filter face velocity – Evaluation of the supply airflow rate without a flowhood may be done with an anemometer downstream of each final filter. The supply airflow rate is determined from the airflow velocity multiplied by the area of exit.
  • 58. Cleanrooms Slide 58 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Test Methods Air pressure difference test  Verify the capability of the complete installation to maintain the specified pressure difference between separate spaces  With all doors closed, the pressure difference between the cleanroom and any surrounding should be measured and recorded.  The following should be considered: – installation of permanent measuring points; – take measurements near the middle of the cleanroom away from any supply air inlets or return air outlet.
  • 59. Cleanrooms Slide 59 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Test Methods Installed filter system leakage test  To confirm that the filter system is properly installed and that leaks have not developed  Introducing an aerosol challenge upstream of the filters and scanning immediately downstream of the filters and support frame or by sampling in a downstream duct.  Applied to cleanrooms in “as-built” or in “at-rest” occupational states, and when commissioning new cleanrooms, or existing installations require re-testing, or after the final filters have been replaced  Detection of leakage by Scanning / Stationary remeasuring
  • 60. Cleanrooms Slide 60 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Test Methods: Filter Leakage Test
  • 61. Cleanrooms Slide 61 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Test Methods  Apparatus and materials for installed filter system leakage tests – Aerosol photometer – Discrete-particle counter (DPC) – Suitable pneumatic or thermal aerosol generator(s) – Suitable aerosol dilution system. – Suitable aerosol source substances
  • 62. Cleanrooms Slide 62 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Test Methods Airflow direction test and visualization  To confirm that the airflow direction and its uniformity conform to the design and performance specifications  can be performed by the following four methods: 1. Tracer thread method; silk threads, single nylon fibers, flags or thin film tapes and effective lighting 2. Tracer injection method; tracer particles illuminated by high intensity light sources (DI Water , alcohol/glycol) 3. Airflow visualization method by image processing techniques; (Quantitative) 4. Airflow visualization method by the measurement of velocity distribution.
  • 63. Cleanrooms Slide 63 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Test Methods: Air Flow Visualization
  • 64. Cleanrooms Slide 64 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Test Methods  Temperature test – Capability to maintain the air temperature level within the control – Measured at a minimum of one location for each temperature- controlled zone. – Measurement time should be at least 5 min with one value recorded at least every minute. – Comprehensive temperature test: • At least 1 h after the air-conditioning system has been operated • The number of measuring locations should be at least two. • Probe should be positioned at work-level height and at a distance of no less than 300 mm from the ceiling, walls, or floor of the installation
  • 65. Cleanrooms Slide 65 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Test Methods  Humidity test – Capability to maintain the air humidity level – Expressed as relative humidity or dew point – The sensor should be located at least at one location for each humidity control zone, and sufficient time should be allowed for the sensor to stabilize. – The measurement time should be at least 5 min.
  • 66. Cleanrooms Slide 66 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Test Methods  Particle deposition test – Sizing and counting particles that can be deposited from the air onto product or work surfaces in the installation. – Particles are collected on witness plates with surface characteristics similar to those of the at-risk surface – Are sized and counted using optical microscopes, electron microscopes, or surface scanning apparatus. – The witness plate should be placed in the same plane as the at-risk surface. And at the same electrical potential as the test surface.
  • 67. Cleanrooms Slide 67 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Test Methods  Recovery test – Ability of the installation to eliminate airborne particles. – Only important and recommended for non-unidirectional airflow systems – This test is not recommended for ISO Classes 8 and 9. – 100:1 recovery time is defined as the time required for decreasing the initial concentration by a factor of 0,01
  • 68. Cleanrooms Slide 68 of 68 November 2014 Tehran University of Medical Sciences School of Pharmacy Test Methods  Containment leak test – Determine if there is intrusion of contaminated air into the clean zones from non-controlled areas – Particle concentration outside should be greater than the cleanroom concentration by a factor of 103. If the concentration is less, generate an aerosol. – To check for leakage through construction joints, cracks or service conduits, scan inside the enclosure at a distance of not more than 5 cm from the joint, at a scan rate of approximately 5 cm/s.