SlideShare a Scribd company logo
1 of 2
MEDICAL RUBBER KT 001 Filaments
Technical Data sheet
rev. 1
DESCRIPTION
MEDICAL RUBBER KT001 is 3D Printing Filament in elastomer.
APPLICATIONS
3D Printing Prototyping Technologies
Property Test Condition Standard Unit Values
Mechanical Properties
Tensile Strength, at Break ASTM D 638 MPa 16
Elongation at Break ASTM D 638 % 800
Flexural Modulus ASTM D 790 MPa 35
SHORE D hardness 15” ASTM D 2240 Point 25
Other Properties
Specific Gravity ISO 1183 g/cm3 1,05
Processing
Printing Temperature Range °C 230 - 250
Keytech s.r.l. - via Coppetella, 4 60035 Jesi (AN) - Italy
REA 183526 P. I.V.A. C.F. 02387630425 – s.corinaldesi@gmail.com
MEDICAL RUBBER KT 001 Filaments
Technical Data sheet
SUPPLY FORM
MEDICAL RUBBER KT001 is supplied as Filaments. It has to be kept in its original
packaging. Avoid direct exposure to sunlight.
HAZARD AND HANDLING PRECAUTIONS
MEDICAL RUBBER KT001 is a copolyester based elastomer have a very low degree of toxicity
and, under normal conditions of use, should pose no unusual problems from incidental ingestion, or
eye and skin contact. However, caution is advised when handling, storing, using, or disposing of
these resins, and good housekeeping and controlling of dusts are necessary for safe handling of
product. Workers should be protected from the possibility of contact with molten resin during
fabrication. Handling and fabrication of resins can result in the generation of vapours and dusts that
may cause irritation to eyes and the upper respiratory tract. In dusty atmospheres, use an approved
dust respirator. Pellets or beads may present a slipping hazard. Good general ventilation of the
polymer processing area is recommended. At temperatures exceeding the polymer melt temperature,
polymer can release fumes, which may contain fragments of the polymer, creating a potential to
irritate eyes and mucous membranes. Good general ventilation should be sufficient for most
conditions.
PROCESSING
MEDICAL RUBBER KT001 Filaments can be processed by all conventional 3D printing
techniques. Mass temperature can be less as 260°C..
DISPOSAL
DO NOT DUMP INTO ANY SEWERS, ON THE GROUND, OR INTO ANY BODY OF WATER.
For unused or uncontaminated material, the preferred options include recycling into the process or
sending to an industrial composting facility, if available; otherwise, send to an incinerator or other
thermal destruction device. For used or contaminated material, the disposal options remain the
same, although additional evaluation is required. (For example, in the U.S.A., see 40 CFR, Part 261,
“Identification and Listing of Hazardous Waste.”) All disposal methods must be in compliance with
Federal, State/Provincial, and local laws and regulations.
DISCLAIMER
The above information is provided in good faith. Keytech is not responsible for any processing or
compounding which may occur to product finished articles, packaging materials or their
components. Further, MEDICAL RUBBER KT001 MAKES NO WARRANTY OR
REPRESENTATION OF ANY KIND, REGARDING THE INFORMATION GIVEN OR THE
PRODUCTS DESCRIBED, AND EXPRESSLY DISCLAIMS ALL IMPLIED WARRANTIES,
REPRESENTATIONS AND CONDITIONS, INCLUDING WITHOUT LIMITATION ALL
WARRANTIES AND CONDITIONS OF QUALITY, MERCHANTABILITY AND SUITABILITY
OR FITNESS FOR A PARTICULAR PURPOSE. Responsibility for use, storage, handling and
disposal of the products described herein is that of the purchaser or end user.
Keytech s.r.l. - via Coppetella, 4 60035 Jesi (AN) - Italy
REA 183526 P. I.V.A. C.F. 02387630425 – s.corinaldesi@gmail.com

More Related Content

More from Stefano Corinaldesi

More from Stefano Corinaldesi (20)

Msds tek 200-ita
Msds tek 200-itaMsds tek 200-ita
Msds tek 200-ita
 
Covid19 la-gestione-dei-rifiuti-rappresentati-da-dpi-mascherine-guanti-ecc-pr...
Covid19 la-gestione-dei-rifiuti-rappresentati-da-dpi-mascherine-guanti-ecc-pr...Covid19 la-gestione-dei-rifiuti-rappresentati-da-dpi-mascherine-guanti-ecc-pr...
Covid19 la-gestione-dei-rifiuti-rappresentati-da-dpi-mascherine-guanti-ecc-pr...
 
Green apple smell, dlp lcd clear resin
Green apple smell, dlp lcd clear resinGreen apple smell, dlp lcd clear resin
Green apple smell, dlp lcd clear resin
 
Breviario i med-01
Breviario i med-01Breviario i med-01
Breviario i med-01
 
Msds ver-new or sver-new
Msds ver-new or sver-newMsds ver-new or sver-new
Msds ver-new or sver-new
 
First worldwide PBT filament food contact approved
First worldwide PBT filament food contact approvedFirst worldwide PBT filament food contact approved
First worldwide PBT filament food contact approved
 
pbt contatto alimentare ita
pbt contatto alimentare itapbt contatto alimentare ita
pbt contatto alimentare ita
 
ZCORY PLUS V2 –THERMAL BARRIER -
ZCORY PLUS V2 –THERMAL BARRIER -ZCORY PLUS V2 –THERMAL BARRIER -
ZCORY PLUS V2 –THERMAL BARRIER -
 
DLP Antibacteric Resin
DLP Antibacteric ResinDLP Antibacteric Resin
DLP Antibacteric Resin
 
MSDS TGK RESIN CLEANER
MSDS TGK RESIN CLEANERMSDS TGK RESIN CLEANER
MSDS TGK RESIN CLEANER
 
Multi bed for zortrax m200
Multi bed for zortrax m200Multi bed for zortrax m200
Multi bed for zortrax m200
 
MSDS TGK ODORLESS AND NOT FLAMMABLE SOLVENT FOR FORMLAB RESIN AND SIMILAR
MSDS TGK ODORLESS AND NOT FLAMMABLE SOLVENT FOR FORMLAB RESIN AND SIMILARMSDS TGK ODORLESS AND NOT FLAMMABLE SOLVENT FOR FORMLAB RESIN AND SIMILAR
MSDS TGK ODORLESS AND NOT FLAMMABLE SOLVENT FOR FORMLAB RESIN AND SIMILAR
 
Trasparent paint removed from carbon sheet autoclaved
Trasparent paint removed from carbon sheet autoclavedTrasparent paint removed from carbon sheet autoclaved
Trasparent paint removed from carbon sheet autoclaved
 
TEK 1960 MSDS EN
TEK 1960 MSDS ENTEK 1960 MSDS EN
TEK 1960 MSDS EN
 
TDS TEK 1969
TDS TEK 1969TDS TEK 1969
TDS TEK 1969
 
MSDS TEK1969_EN_1
MSDS TEK1969_EN_1MSDS TEK1969_EN_1
MSDS TEK1969_EN_1
 
100% safe liquid alternative to IPA for DLP and SLA washing
100% safe liquid alternative to IPA for  DLP and SLA washing100% safe liquid alternative to IPA for  DLP and SLA washing
100% safe liquid alternative to IPA for DLP and SLA washing
 
MSDS Tek 1969 rev.-3_ita
MSDS Tek 1969 rev.-3_itaMSDS Tek 1969 rev.-3_ita
MSDS Tek 1969 rev.-3_ita
 
Z Plate for M 200 Zortrax
Z Plate for M 200 ZortraxZ Plate for M 200 Zortrax
Z Plate for M 200 Zortrax
 
3D Printer OptiPlico 10 M
3D Printer OptiPlico 10 M3D Printer OptiPlico 10 M
3D Printer OptiPlico 10 M
 

Medical rubber kt001 3 d printing filament data sheet

  • 1. MEDICAL RUBBER KT 001 Filaments Technical Data sheet rev. 1 DESCRIPTION MEDICAL RUBBER KT001 is 3D Printing Filament in elastomer. APPLICATIONS 3D Printing Prototyping Technologies Property Test Condition Standard Unit Values Mechanical Properties Tensile Strength, at Break ASTM D 638 MPa 16 Elongation at Break ASTM D 638 % 800 Flexural Modulus ASTM D 790 MPa 35 SHORE D hardness 15” ASTM D 2240 Point 25 Other Properties Specific Gravity ISO 1183 g/cm3 1,05 Processing Printing Temperature Range °C 230 - 250 Keytech s.r.l. - via Coppetella, 4 60035 Jesi (AN) - Italy REA 183526 P. I.V.A. C.F. 02387630425 – s.corinaldesi@gmail.com
  • 2. MEDICAL RUBBER KT 001 Filaments Technical Data sheet SUPPLY FORM MEDICAL RUBBER KT001 is supplied as Filaments. It has to be kept in its original packaging. Avoid direct exposure to sunlight. HAZARD AND HANDLING PRECAUTIONS MEDICAL RUBBER KT001 is a copolyester based elastomer have a very low degree of toxicity and, under normal conditions of use, should pose no unusual problems from incidental ingestion, or eye and skin contact. However, caution is advised when handling, storing, using, or disposing of these resins, and good housekeeping and controlling of dusts are necessary for safe handling of product. Workers should be protected from the possibility of contact with molten resin during fabrication. Handling and fabrication of resins can result in the generation of vapours and dusts that may cause irritation to eyes and the upper respiratory tract. In dusty atmospheres, use an approved dust respirator. Pellets or beads may present a slipping hazard. Good general ventilation of the polymer processing area is recommended. At temperatures exceeding the polymer melt temperature, polymer can release fumes, which may contain fragments of the polymer, creating a potential to irritate eyes and mucous membranes. Good general ventilation should be sufficient for most conditions. PROCESSING MEDICAL RUBBER KT001 Filaments can be processed by all conventional 3D printing techniques. Mass temperature can be less as 260°C.. DISPOSAL DO NOT DUMP INTO ANY SEWERS, ON THE GROUND, OR INTO ANY BODY OF WATER. For unused or uncontaminated material, the preferred options include recycling into the process or sending to an industrial composting facility, if available; otherwise, send to an incinerator or other thermal destruction device. For used or contaminated material, the disposal options remain the same, although additional evaluation is required. (For example, in the U.S.A., see 40 CFR, Part 261, “Identification and Listing of Hazardous Waste.”) All disposal methods must be in compliance with Federal, State/Provincial, and local laws and regulations. DISCLAIMER The above information is provided in good faith. Keytech is not responsible for any processing or compounding which may occur to product finished articles, packaging materials or their components. Further, MEDICAL RUBBER KT001 MAKES NO WARRANTY OR REPRESENTATION OF ANY KIND, REGARDING THE INFORMATION GIVEN OR THE PRODUCTS DESCRIBED, AND EXPRESSLY DISCLAIMS ALL IMPLIED WARRANTIES, REPRESENTATIONS AND CONDITIONS, INCLUDING WITHOUT LIMITATION ALL WARRANTIES AND CONDITIONS OF QUALITY, MERCHANTABILITY AND SUITABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Responsibility for use, storage, handling and disposal of the products described herein is that of the purchaser or end user. Keytech s.r.l. - via Coppetella, 4 60035 Jesi (AN) - Italy REA 183526 P. I.V.A. C.F. 02387630425 – s.corinaldesi@gmail.com