More Related Content
Similar to SCS6000 Controlled Atmosphere Control System (20)
SCS6000 Controlled Atmosphere Control System
- 1. T U P S B H F ! D P O U S P M ! T Z T U F N T - ! J O D
1 0 0 A P P L E W O O D D R I V E · S P A R T A M I C H I G A N 4 9 3 4 5 · U N I T E D S T A T E S O F A M E R I C A
T 6 1 6 . 8 7 7 . 7 9 9 4 · F 6 1 6 . 8 7 7 . 1 1 2 8 · I N F O @ S T O R A G E C O N T R O L . C O M · S T O R A G E C O N T R O L . C O M
© 3 1 2 8 ! T U P S B H F ! D P O U S P M ! T Z T U F N T - ! J O D / ! ! B M M ! S J H I U T ! S F T F S W F E / ! ! D P O U B D U ! V T ! G P S ! N P S F ! J O G P S N B U J P O©
TDT7111!DB!DPOUSPM!TZTUFNThe SCS6000 system is the latest in a long line of integrated systems for the
measurement and control of Controlled Atmosphere fruit or vegetable storage rooms. It
is an extremely flexible system that is configured to meet the needs of each application
and can have a capacity from 4 to 56 rooms. The system is independent of any
proprietary CA machinery and can be used with many types of carbon dioxide and
oxygen control equipment.
The SCS6000 includes gas analyser sensors which are regularly checked for calibration
and can be set to automatically correct for any drift. The sampling system comprises a
high quality pump, vacuum gauge and filter/separator. The PLC controls the room
sampling sequence by selecting the appropriate sampling solenoid valves. For small
cabinets used in research and CA testing the system can be built with solenoids to return
the sample gas.
Control outputs for room ventilation, nitrogen purge and CO2 scrubbing are time
proportional to provides accurate control of the gas atmosphere in each storage room.
Control of CO2 add is also available for specialist applications such as berry storage.
Temperature is measured from up to 6 probes per room with the high accuracy SCS28
temperature probes. Connection is available to permit the SCS6000 to monitor the
settings and operation of Dixell room temperature controllers. Inputs are also available
for Humidity measurement, Ammonia or other refrigeration gas alarm and the
measurement of ethylene from 0.2 to 25 ppm.
The operation of the SCS6000 is from a touch screen controller which permits all
readings and setting adjustments to be easily made. This screen can also be accessed
remotely on a connected PC or mobile device. The SCS6000 is connected to a standard
Ethernet network and has its own IP address for connection to a wired or wireless
network and through a broadband internet connection using industry standard IT
techniques.
There is additional .NET software available to use on a connected PC computer to
provide full screen data displays and tabular and graphical reports which can be stored
and exported in many common data formats. Alarm alerts can be sent directly by email
from the controller to a mail address of choice.
The modular design of the system is taken to another level with all the input and output
modules interconnected with an industry standard CANbus network that uses a single
twisted pair wire connection. This permits the simplification of the installation with
substantial savings to be made in wiring and pipework.
The flexibility of the design gives the ability to provide systems from a simple one box
system for 2 CA rooms to a full 56 way laboratory. Upgrades are also available for David
Bishop OXYSTAT systems and ICA61 controllers.
A version of the SCS6001 is also available for temperature and RH monitoring without
the gas analyser functions.
For more information please ask for a copy of the manual and a detailed specification
sheet.
SCS6000 in CA Research Lab
Full Touchscreen or Remote Online Operation
Hand Built in the UK using Bespoke SCS Controllers