1. KS-306FCT
KS-306FCT wireless curtain passive infrared detector adopts
advanced illegible logic intelligent recognising technology. It can detect
KS-306FCT Wireless Curtain PIR Detector
the intruder crossing the defence area. It is with automatic temperature
compensation and intelligent direction recognising function. It has the
advantage of low rate of false alarm, stable and easy installation in the
window, aisle and so on.
1.Main functions and features
* Anti- electromagnetic interference and spotlight; pet immune and low
false alarm
*The static current is particularly small, and two pieces of size
“AA” dry battery can be used for one year
*Two levels sensitivity setup, temperature compensation.
*One-way or two ways (direction) alarm are available.
*Directional recognition and time are adjustable in one-way mode.
*Easily installed on the wall or ceiling.
*Wireless transmission adopts SAWF
2.Cover opening
(1) Open
Users’ Manual
Insert the “-” screwdriver Unclench the screwdriver R emove the cover and
upright to the back hole of and the open the cover install the battery or set
the unit if n eed
V2.0
-1-
KS-306FCT KS-306FCT
(2) Close Transmitter jumper: be used for transmitting only.
Indicator:
Flash once: power on and initializing
Flash twice: finish initializtion/returning time arrival or trigger again
in returning time
Flash three times: when detecting intruder, it will send alarm signal to
panel
Match the hole of cover and press to close Flash five times: when detecting person goes from inside to outside, it
won't send alarm signal to panel.
Flash once every five seconds: battery low, please replace battery
3.Component Description
immediately.
Flash once per five seconds: low power
Infrared sensor: to detect the body infrared signal, it required to keep
in cleanness
Detective distance option(JP5)
Jumper inserted: high sensibility, detective distance is 1-8m(default)
Jumper removed: low sensibility, detective distance is 1-4m Please
choose the low sensibility if it meets the requirement
Anti-temper switch: when shell be opened and destroyed, the detector
will alarm
Battery case: put in two pieces of size “ AA” dry battery with the right
polarity as picture
Function jumper:
(3) Jp1: Mode option: to choose the working mode
8 (Note) (5) (6) (7)
4°
√ √ ×
√Alarm √ × √
× No Alarm A B A B A B
(4) Alarm in two directions A larm in o ne dire ction Mode 1 A larm in one direction Mode 2
-2- -3-
PDF created with pdfFactory trial version www.pdffactory.com
2. KS-306FCT KS-306FCT
Jumper removed: alarm in two directions, as picture 5,it will alarm Body Moving
W in d ow an d doo r Barrier
both from A to B and B to A (default)
Jumper inserted:alarm in one direction, as picture 6 and 7, it will alarm Air-condition
Carbinet
only in one direction, which depends on the Jp2
JP2: Direction option: to choose the direction when alarm in one
direction (only available for one direction mode)
Jumper Removed:one direction mode 1, as picture 6, it will alarm from
A to B but not B to A (default)
Jumper inserted:one direction mode 2, as picture 7, it will alarm from B
× × × ×
(8) (9) (10) (11)
4.Installation requirement
to A but not A to B As picture 8, stand off from the door and windows,,stand off the
It will be an opposite alarm direction with the JP2 jumper and without straight light (eg. Spotlight)
JP3: Returning time: to set up the longest lasting time when the person As picture 9, the detector is sensitive with the air convection and
comes across from one direction to another before returning back.(only temperature, so stand off the warm or cold sources and heavy air
available for one direction mode in JP1) convection, eg.,air flowing place, air-condition,electric radiators,door and
Jumper removed: 15 seconds (default) windows, etc.
Jumper inserted:4 minutes The infrared detector has the highest sensitivity when a human body
Eg: In JP1 Mode with jumper inserted (alarm in one direction), In JP2 moves parallel with the detector , pic 5, and the sensitivity is the lowest
mode with jumper removed (one direction mode 1, pic 6), in JP3 mode when vertically against the detector, pic 10.
with jumper removed (maximum 15 seconds), as picture 6 There is no barrier within the defended area of a detector, as pic 11
If person comes from A to B, it will alarm Choose the best location according to the requirement.
If person comes from B to A, the detector will count the time and has two
( 12 ) Installation
cases:
Ceiling
The detector won’t alarm if the person comes back from A to B within 15
seconds
The detector will alarm if the person comes back from A to B beyond 15
seconds
Wireless addressable code: not need to change it unless needed , If
needed please do it under the professional instruction. Wall Wall
1 0 0°
-4- -5-
KS-306FCT KS-306FCT
3 times, then the panel alarms. disarm the panel immediately and arm
5.Installation and being used again, come across the detector after waiting for 8 seconds, and see if it
Open the shell and set if needed, pic 1 alarms again. If it alarms in some times when testing, it is ok and can be
Put in the battery with the right polarity as picture 3, the indicator flash used.
once, and it begins to initialize If simulative test is failure, please check the setting and installation to
It finishes the initialization with flash twice. Then register the detector see if they are correct. and test again until it is successful.
to the panel (utilizing the anti-temper switch to trigger detector is Note:
The detector is designed for indoor use only.
available). Arm the panel, and trigger the anti-temper (press the anti-
Every alarm requires 8 seconds minimum interval.
temper metal bar for 2 seconds and loosen it), the detector will emit the
For each setup, it is required to re-install the battery and power on again
signal and flash three times, and the panel alarms, that is finished. If
to get effect.
failure, try again.
It is required to inspect the detector periodically, and repair if any trouble.
Cover the shell, as pic 2, have a motion about 20cm in front of If it is in battery low (flash every 5 seconds), change the battery
detector to create a simulative alarm to test, if it is not meet the immediately to avoid alarm lose.
requirement, it have to reset.
6.Technical Parameter
Fasten the mounting bracket on the required place with nail or
Detective distance: <8 m
screw, pic 13, and then mount the detector bearer on the bracket, as pic
Detective angle: as picture 5 and 12
14, adjust the angle and screw the bearer in the bracket . Then put out the
Working voltage: DC3V(2pcs, Size AA dry battery 1.5V)
full antennas to reach the better effect.
Initialization time: 20-120 seconds
Create a simulative alarm:arm the panel, after initialization, the human
Standby current: <60u A
body move across the detector, as pic 6 and 7, and the indicator will flash
Emission frequency:433.92MHz
Working temperature: -10C-+50C
Wireless distance:1-400m(in the open area)
Time between two alarm: >8s
Size: 110mmX70mmX40MM
Net weight: 103g(without battery)
( 13 ) ( 14 ) ( 15 ) ( 16 )