pH Chart
How to Measure : Place 10-15 ml of test water in a
container and add 2-3 drops of reagent. Then, mix well
and check color of the water with the pH chart above.
(Color is dependent on water quality and reagent)
User’s Manual
Under Counter Extream
MADE IN KOREA
2. UCE-9000 Turbo user’s manual
To Our Valued Customers Table of contents
To Our Valued Customers 2
Thank you for purchasing the UCE-9000 Turbo Water Ionizer.
Before Usage 4
Please read all safety warnings and this User’s Manual carefully
before using this product to ensure proper product usage. (Keep the Safety Precautions and Warnings 5
manual handy for easy reference.) Dispenser Overview 10
Unit Overview 11
• We are not responsible for any accidents and/or malfunctions due
to the improper use of this machine. Product Features 12
• Please keep the manual and warranty card in a safe place, so that Package Contents 16
it’ easily accessible when you need it.
s
Parts Drawing for Installation 17
• Please refer to this manual often when you have questions during
Under-Sink Installation 18
usage or when troubleshooting this unit.
Dispenser Installatio 19
Ionizer Installation 21
Customer Serviceable Parts 23
How to Change the Filters 24
Operation Touch Screen 26
To Our Valued Customers
Unit Usage 30
Intended Use System Setup Method 32
Voice On/Off Selection 36
Table of contents
Manual Cleaning Function 37
This device creates functional alkaline, ionized water. It changes
the properties of regular tap water through the use of electrolysis. Eco Mode 38
Following are the changes normal tap water undergoes via this process: Turbo Function 39
• An increase or decrease in pH level Recommendations for using this unit 40
• Creation of negatively charged hydrogen ions (anti-oxidants) Hot Water Sensor 42
• Smaller water molecule clusters for better absorption
Unit Specifications 43
• An increase in oxygen
Troubleshooting 44
• Purification through filtration
2 3
3. UCE-9000 Turbo user’s manual
Before Usage Safety Precautions and Warnings
Safety precautions are provided for the safe and proper use of this unit and can Regarding Power Supply
prevent danger, bodily harm and/or possible damage due to misuse. Please make
sure you are familiar with all the safety precautions and warnings associated with
this unit.
Do not use if the power cord is damaged or
in a loose power outlet.
DANGER (Red Warning Sign) WARNING (Orange Warning Sign) ATTENTION (Yellow Warning Sign)
–indicates an imminent hazard – indicates a potential hazard that – indicates a potential hazard that
that could result in serious injury could result in significant bodily harm could result in minor bodily harm or
or death. If you see this, stop the or damage to the unit. If you see this, damage to the unit.
Do not pull the power cord. Never touch power
use of this unit immediately. stop the use of this unit. cord or power outlet with wet hands.
PLEASE FOLLOW ALL INSTRUCTIONS WHEN YOU DRINK WATER CREATED BY
ELECTROLYSIS FROM THIS UNIT. (Hereinafter referred to as“functional water”)
Do not use power surge protectors with this unit.
Use unit with its own dedicated power source.
Safety Precautions and Warnings
1. Do not drink functional water with medication. 7. dispensed from this unit on a monthly basis
Use filtered Water instead. to ensure proper function. This can be done
with the supplied reagent drops and a pH
2. Always consult your primary care physician color chart.
before drinking functional water. Only drink
a small amount for the first week near a 8. When switching from one pH to another,
neutral pH level. This will give the body time it is good practice to let the water run for Do not forcibly bend, squeeze, damage or
to adjust to functional water during the several seconds before using. crush the power cord under heavy objects.
detoxification period.
9. It is common to drink half your body weight
3. If you notice any negative effects from drinking in ounces. For example, if you weigh 180
functional water, stop drinking immediately pounds, it may be wise to drink 90 ounces
and consult with your primary care physician of water per day. This especially applies
about changes in your body’s pH level. after you have given your body some time
to adjust to the new pH level. Unplug the power cord during general maintenance,
Before Usage
4. If you are currently under the care of a repair, inspection and while replacing parts.
primary care physician for an existing 10. 9.5 to 9.8 pH is the recommended drinking
condition, consult with your primary care level for functional water. It is not recommen
physician about how changes in pH and ded to drink functional water above 10 pH.
other characteristics of functional water
could affect your condition. 11. If you wish to store functional water, use a
glass, stainless steel or other non-leaching
5. If you suffer from gastric anacidity, kidney material and store in the refrigerator.
failure or potassium excretion, you should Only use the unit with the correct voltage.
not drink functional water. 12. Never run hot water through this unit.
6. Verify the pH levels of the functional water 13. Never drink acidic water.
4 5
4. UCE-9000 Turbo user’s manual
Usage
Do not spray water on the main unit. Do not
Do not place ANY objects on top of this unit
clean with a damp cloth, benzene or other
regardless of how small.
chemicals, which may leak into the unit.
In case of strange noises, burning odor or smoke,
unplug the power cord immediately and refer Do not store unit near chemicals, food, metals
servicing to qualified service personnel. or medication.
benzene thinne
r
In case water leaks out of the unit (other than
hoses) or unit is standing in a puddle of water, Do not poke or scratch the touch pad or LCD
shut off the water supply, unplug the power cord display with sharp objects.
and refer servicing to qualified service personnel.
Safety Precautions and Warnings
Safety Precautions and Warnings
Replace filters every 6 months to optimize the It is beneficial for the maintenance of the machine
purification performance of this unit even if the to run a strong acidic level for a period of 5
replacement indicator light isn’t turned on. minute cycles twice weekly. This will help to
maintain a clean chamber.
Do not use alkaline or acidic water in fish bowls
or aquariums. The sudden change in pH could
be harmful or fatal to some marine life.
To reduce the risk of electric shock, do not
remove cover; no user-serviceable parts inside.
Refer servicing to qualified service personnel.
Removing the cover will void the warranty.
6 7
5. UCE-9000 Turbo user’s manual
Installation Storage
In the case where the unit isn’used over a
t
Do not place this unit near heat sources. long period of time, shut off the valve and unplug
the power cord.
Remove the filters and turn them upside down
Do not connect water line to a hot water supply.
to remove excess water before storing.
Do not place this unit on an uneven surface. In case the original packaging is not available,
Do not drop or use excessive force on this unit. cover the unit in plastic to avoid scratching the
Safety Precautions and Warnings
Safety Precautions and Warnings
surface.
Carefully remove this unit from packaging. Keep
Do not use unfit raw water in accordance to the original packaging for future storage and unit
standards of the water service act. transportation.
Do not use in areas of high humidity and/or high Store unit in its original packaging in a cool, dry
temperature. place when not in use.
8 9
6. UCE-9000 Turbo user’s manual
Dispenser Overview Unit Overview
Front View Rear View Front View Rear View
13.2cm
39.3cm
5.2inch
15.5inch
4
5
16cm
36cm
6
6.3inch 29.5cm
11.6inch 14.1 inch
11cm 38.2cm
15inch ● Front Case
1 1
● Hanging Groove
4.3inch 17.2cm
13.2cm 6.8inch ● Front Cover
2 2
● Rear Case
5.2inch
3
● Product Sticker
● Front Door Case
3
4
● Power Swich
5
● Fuse
6
● Power Cord
3.3cm
1.3inch
SINK
Bottom View
Dispenser Overview
5cm
2inch
Unit Overview
5
● Jog Dial
1
● Water Outlet Pipe
2
● Drain Pipe
3
● Alkaline Outlet
1 ● MCU Cable
4
● Fixing Nut
4
● Acid Outlet
2 ● Power Code
5
● Speaker
5 ● Tap Water Inlet
3
10 11
7. UCE-9000 Turbo user’s manual
CARE FOR EARTH’S ENVIRONMENT
Product Features
Leading Environmentally Friendly Technology by ECO MODE
A DESIGN MASTERPIECE True energy saving is accomplished with ultra low power consumption
during periods of non-use.
An Object that Offers both Kitchen Space & Ultimate Beauty
The Tyent’ Under Counter Extreme Water Ionizer not only attracts
s
person’s gaze with its well-differentiated appearance, but also MORE POWERFUL SYSTEM ENGINE !
helps to upgrade your kitchen’s interior decoration with a neat
and luxurious expression.
Upgraded TURBO SYSTEM
Turbo upgrades to the SMPS Type Power Supply system produce
FULL TOUCH LCD – TRANSFORMATION AT YOUR FINGERTIPS both the acid turbo water and strong alkali water you need!
Industry First Full Touch Screen Panel
The Full Touch Screen Panel System automatically activates
SMPS Type Power Supply System
the unit’ operations through a simple touch to the desired icon
s
displayed on the screen. SMPS Type Power Supply System provides the maximum
instantaneous output needed to produce the highly stable electric
power required for each phase of electrolysis.
TFT LCD Screen with a Clear Picture Tone
9 Electrodes with Round-Mesh Plate Technology
A 262,000 Color TFT LCD Display provides diverse information in
true vivid colors for user convenience. These 9 Platinum-Coated Titanium Plates are made with highly
stable, durable mesh technology that enhances the instantaneous
electrolysis efficiency.
Graphical User Interface
CAREFUL CONSIDERATION FOR THE USER
A Graphical User Interface is designed specifically for ease of use
Product Features
Product Features
and operation. Communication between the user and ionizer has
never been this simple! Light and Screen Indicators for Water Discharge Detection
Changes to the LCD screen and Jog Dial light can be easily
identified to check each selected phase.
JOG DIAL & TOUCH
Jog Dial & Touch with 2-Way Operation Compatibility Excellent MP3 Sound Quality with Guided Support
Choose from either the Jog Dial or the Touch Screen Panel system Functions under operation can be further identified by the top-
–both are available with 2-way operation compatibility and are quality voice guided system.
easy to use at your convenience
12 13
8. UCE-9000 Turbo user’s manual
Temperature Sensor Function for Safe Operation SELF MAINTENANCE MADE EASY – FROM INSTALLATION TO AFTER-SERVICE
If the temperature of the source water exceeds the normal operation Real Time Filter Usage Indication and Replacement Time Guide
range of 4~35℃ degrees Celsius, the incoming flow of water
is automatically interrupted, displaying a Warning Sign on screen. Level of filter usage can be identified through the LCD Screen on
a real time basis. The recommended replacement time is automatically
displayed on the screen with a voice guide.
Automatic Water Discharge Interruption Function
In order to prevent the overflow of water due to user negligence, Super Simple Filter Replacement System
the water discharge is automatically stopped after 15 minutes of use.
A simple filter replacement system along with one-touch Filter
Usage Initialization Setting System makes filter management easy
for any one.
Automatic Electrolysis Tank Cleaning Function
The interior of the Electrolysis Bath is automatically cleaned on a Convenience of Operating Condition Setting System
regular basis, ensuring stable electrolysis operating conditions.
Easy Setting System familiar to common users is employed, allowing
the convenience of setting or canceling the desired through the
LCD Screen.
Automatic Memory Function
The last function used by the user is automatically memorized and pH Control Function
displayed on the Standby Screen for fast and convenient operation.
Respective alkali, acid & turbo phases can be easily controlled
by the user.
Water Discharge Nozzle with Directional Control
The water discharge direction may be adjusted to many diverse Self Diagnosis Function
angles based on user preference.
When the condition of the source water is not suitable, the water
discharge is automatically suspended, displaying a Warning Sign
Product Features
Product Features
on screen.
FRESH, PURIFIED WATER IS A MUST ALONG WITH HEALTHY MINERALS!
Water Purification through Clean Processes and Minerals
Perfect, seamless elimination of foreign substances including residual
chlorine, organic & inorganic compounds through the filtering process
using functional UF and ∏ Ceramic materials, enhancing the alkali
water producing condition.
14 15
9. UCE-9000 Turbo user’s manual
Picture of components can be different from the real ones, and some items may be changed according to the situation.
Package Contents Parts Drawing for Installation
Ionizer
dispenser
fixing nut
Dispenser
Rubber packing
Rubber packing
rubber packing
(2EA) Bottom
Fixing nut
Tap water inlet Alkaline hose
Acid hose Acid outlet MCU cable
Acid hose
Water Outlet Pipe
Alkaline hose Union connector
Parts Drawing for Installation
Stem elbow Alkaline outlet Tap water hose
MCU cable connector
Cable Tie Cable tie
Wrench
MCU cable
Package Contents
Tap Water
hose
Adapter Adapter
Stem Elbows
(3EA) Acid hose
(Orange)
&
Alkaline hose
(White) Ionizer
L
UA
AN
M
Tap water hose
User’ Manual
s pH Testing
Solution Bottle
16 17
10. UCE-9000 Turbo user’s manual
Under-Sink Installation Dispenser Installation
1 First, the fixed nut to remove it from the
dispenser.
Water Outlet Pipe 2 Press the outflow pipes into the holes of the
dispenser.
*upper hole: water outlet pipe [152mm]
*lower hole : drain pipe [102mm]
1. Purchase either an under-sink installation kit (not included) or purchase
Drain Pipe
T-connection (with shut-off valve) from a hardware or plumbing supply
store.
2. Shut off both hot and cold water main supply at pipe under the sink.
3 Connect each hose from the ionizer to the
union connector. (when you connect the
3. Locate the cold water supply line valve. hoses, please match the hoses by color :
orange ‒ orange, white ‒ white)
4. Disconnect faucet cold water supply line from main cold water pipe–use
towel to catch small amount of water that may come from faucet supply
line.
Under-Sink Installation
Dispenser Installation
5. When connecting T-connection to cold water pipe, be sure to use plumbing
pipe thread seal tape (not included) to prevent leaks.
6. Reconnect faucet cold water supply line to T-connection. (now secured 4 Use a 32Ø drill bit to drill the hole.
32Ø
to main cold water pipe)
7. Be sure all connections are secure but do not over tighten.
*Do not turn on main water supply until all hoses are properly installed to
the unit.
18 19
11. UCE-9000 Turbo user’s manual
Ionizer Installation
5 Insert one of the provided rubber O-Rings
in the assembled dispenser.
1 Press the stem elbows into the water inflow,
alkali outlet and acidic outlet located on the
bottom of the ionizer.
6 Place the assembled dispenser into the
drilled hole.
acid hose 2 Connect the hoses of the dispenser to the
stem elbows. (when you connect the hoses,
use orange for the acid hose and white for
the alkaline hose)
alkaline hose
7 Insert the second rubber O-ring in the
assembled dispenser located underneath
the sink. 3 Connect the MCU cable of the dispenser to
the MCU cable on the bottom of the ionizer.
8 Tighten the fixing nut underneath the sink.
(do not over tighten) 4 Connect the hose from the inflow hole to
tap water inlet the cold water supply at the under-sink
Dispenser Installation
T-connection.
Ionizer Installation
5 Make sure all hose connections are firmly
seated in the correct holes, both on the
unit and at the water supply.
20 21
12. UCE-9000 Turbo user’s manual
Customer Serviceable Parts
6 Plug in the power cord and turn on the unit.
ATTENTION: The consumer accepts any and all responsibility and/or liability if
replacement filters and/or parts are not manufacturer specific. This unit contains
high-performance purifying filters and an advanced control system.
Primary Filter: 1st Filter
Recommended filter replacement cycle:
※ INTRO Screen appears only when Initial
Power is supplied. 951.0 gallons (3,600 L) / Every 6 months
Removes harmful chemicals like chlorine,
compounds such as agrichemicals and
1st Filter
detergents, large suspended matters like rust
and sediments as well as other volatile organic
compounds through an efficient, activated
absorption method. It also eliminates bad
smells and any remaining dissolved chlorine.
Customer Serviceable Parts
Secondary Filter: 2nd Filter
Recommended filterreplacement cycle:
951.0 gallons (3,600 L) / Every 6 months
Ionizer Installation
2nd Filter
0.01 micrometer artificial film filters contaminated
Caution materials including ordinary bacteria while
maintaining essential minerals in the water.
In the event of a power failure
Remove the power cord from electrical socket and shut off source water
valve. The life of the filter may vary greatly due to use, water pressure, water quality and
seasonal changes. Filters may need to be replaced sooner than the scheduled
time due to these varying conditions, as you may notice reduced water quality or
water taste changing for the worse.
22 23
13. UCE-9000 Turbo user’s manual
How to Change the Filters How to Reset the Filters
1 Turn the power off and unplug the power cord. Shut
off the water supply to the unit. Make sure the faucet
is shut off.
1 1st filter reset icon
2 2nd filter reset icon
2 Open the front door of the unit. Beware of the sharp 1 2
corners of the cover of the unit when opening.
open
1. First Filter Reset
① Press the bottom part of LCD Screen.
MENU Window appears upper the bottom part of LCD Screen.
② To initialize, press the “F1 RESET” icon 2 times.
3 Pull the filter towards you so that it will be easier to *LCD : percentage (%) of initialization of filter
separate turn. The filter will turn more freely when tilted at a
slight angle. Remove the filter by rotating the filter 2. Second Filter Reset
connect
counter-clockwise. Install the new filter by turning ① Press the bottom part of LCD Screen.
it clockwise. Hand tighten only. Tilt the filter back MENU Window appears upper the bottom part of LCD Screen.
How to Change the Filters
into its original upright position. ② To initialize, press the “F2 RESET” icon 2 times.
How to Reset the Filters
*LCD : percentage (%) of initialization of filter
4 Close the cover of the unit. CAUTION! Use the Filter Initialization Icon only after Filter is changed.
How to Change the Fuse
1. Unplug the power cord.
5 Plug the power cord back in, re-engage the water 2. Locate the fuse cap on the lower back of the unit and turn it counter-
supply and switch the unit back on. clockwise to remove it.
3. Pull out the blown fuse and insert a new fuse.
4. Replace the fuse cap.
Important Information
Please be sure to contact manufacturer to obtain the correct fuse. Customer accepts all
reponsibility for damage to unit and other property due to the installation of incorrect fuse.
24 25
14. UCE-9000 Turbo user’s manual
Operation Touch Screen 2 Menu window
Push the upper part of LCD Screen. MENU Window appears below
1 standby mode the upper part of LCD Screen.
Display Line of the Set Status
1 2 3 4
1 setup mode (ref. 32p)
2 voice on/off (ref. 36p)
Functional Water Operation 3 cleaning (ref. 37p)
4 eco mode on/off (ref. 38p)
Display Line of the used amount
of a Filter
Push the bottom part of LCD Screen. MENU Window appears above
[intial: 00%,] the bottom part of the LCD Screen.
Operation Touch Screen
Operation Touch Screen
Icon : description
setup alkaline level 3
1 1st filter reset icon
voice on purified water
voice off turbo water
2 2nd filter reset icon
cleaning acidic level 1
1 2
eco mode on acidic level 2
eco mode off acidic level 3
alkaline level 1 1st filter life indicator
Use the Filter Initialization Icon only after Filter is changed.
alkaline level 2 2nd filter life indicator CAUTION!
(ref 25p)
26 7
27
15. UCE-9000 Turbo user’s manual
3 LCD Display 4 Message Display
selected mode
auto flow stop
time indicator
filter replacement
: : Filter replacement message
temperature error
: : Should water with a temperature higher than 95F (35℃) get into the unit, the water
supply will automatically be shut off and the unit will stop operating.
working indicator
outflow stop
: : In the event of suspen sion of water supply, a warning message is issued prior
to stopping water outflow.
Cleaning takes place automatically and/or manually
: : Auto Cleaning (15 Seconds)
•Performed during water outflow after more than 12 hours of non-operation
•Performed after 30 liters of water outflow
: : Manual Cleaning (15 Seconds)
•User may manually clean unit whenever desired. Simply touch icon.
Operation Touch Screen
Operation Touch Screen
IMPORTANT CAUTIONS in using the TOUCH Screen
Backlight of LCD display will match the pH level color according to water pH 1. Due to the uniqueness of the TOUCH Screen, TOUCH is not recognized if
level being used after icon is pressed. pushed by more than one finger. Please push with only one finger and be
careful of contamination to the screen that may cause damage to the TOUCH.
2. Be careful of electrostatic materials near the TOUCH Screen. Stimulation from
such materials may cause damage to the TOUCH.
3. Screen may not be seen well under direct sunlight.
Alkaline Water 1 Alkaline Water 2 Alkaline Water 3 Acidic Water 1 Acidic Water 2 Acidic Water 3 Clean Water Turbo
Sky Blue Back-Light Blue Back-Light Violet Back-Light Yellow Back-Light Orange Back-Light Deep Pink Back-Light Green Back-Light Red Black Back-Light
4. Do not push the Screen hard with sharp or pointy objects.
28 29
16. UCE-9000 Turbo user’s manual
Unit Usage
2 When JOG Dial is used
1 When TOUCH Screen is used
1 DI
A
JOG
◀
Mode Selection
Turn the JOG Dial clockwise (or counter
L
▶
▶
DIAL
◀JO
clockwise) to select desired function.
G
1 Mode Selection
G
O
D J
IA ◀
L▶
Press the desired icon on LCD Screen. * LCD Display: White edge is displayed
around the selected icon.
DI JOG
2 Water Outflow
A ◀
L
▶
▶
DIAL
◀JO
After checking the selected icon on
G
G
O
D J
IA ◀
L▶
2 Water Outflow LCD screen, push the area of
Water outflow starts. “PUSH ON/OFF”of the JOG Dial.
* LCD Display: Current Outflow Level and Auto
flow Stop time are displayed. Water outflow starts.
DI JOG
3 Water Outflow Stop
A ◀
L
▶
▶
DIAL
◀JO
Press the “PUSH ON/OFF”
G
G
O
D J
3 Water Outflow Stop
IA ◀
L▶
of the JOG Dial to stop the flow.
Press the screen to stop the flow.
4 Standby Mode
4 Standby Mode Moves to standby mode screen.
Moves to standby mode screen. (Last used icon is displayed.)
Unit usage
Unit usage
(Last used icon is displayed.)
30 31
17. UCE-9000 Turbo user’s manual
SYSTEM SETUP METHOD 2 Acidic pH Level Adjustment
1 Alkali pH Level Adjustment 1
1 Press the upper part of LCD Screen.
2 MENU Window appears below the upper
1 part of LCD Screen.
1 Press the upper part of LCD Screen.
2 MENU Window appears below the upper part
of LCD Screen. 2 Press the setup icon
2 Press the setup icon
3 Select “ACIDIC pH”
3 Select “ALKALI pH”
3
3
SYSTEM SETUP METHOD
SYSTEM SETUP METHOD
4 Select desired level. 4 Select desired level.
5 5
4 5 4 5 : LEVEL UP (18%, 19%, 20%.....)
: LEVEL UP (14%, 15%, 16%.....)
: LEVEL DOWN (12%, 11%, 10%.....) : LEVEL DOWN (16%, 15%, 14%.....)
Setup is completed Setup is completed
* If UP/DOWN Icon is pushed, digital number moves by one step
* If UP/DOWN Icon is pushed, digital number moves by one step
Push the RETURN Icon : Move upward by one step. Push the RETURN Icon : Move upward by one step.
32 33
18. UCE-9000 Turbo user’s manual
3 Volume Level Adjustment 4 TIME
1
1
1 Press the upper part of LCD Screen. 2 1 Press the upper part of LCD Screen.
2 MENU Window appears below the upper part MENU Window appears below the upper part of
of LCD Screen. LCD Screen.
2 Press the setup icon 2 Press the setup icon
3
3 Select “TIME”
3 Select “VOLUME”
3
ⓐ Year
ⓑ Month
ⓒ Date
ⓓ Hour
SYSTEM SETUP METHOD
SYSTEM SETUP METHOD
ⓔ Minute
4 ,
4
Select desired VOLUME : Select desired VOLUME
4 Adjustment : /
by pushing +.– Icon.
Setup is completed. - (17, 18, 19 ..... 24)
- (16, 15, 14 ..... 0)
Setup is completed.
4 4
Push the RETURN Icon : Move upward by one step.
Push the RETURN Icon : Move upward by one step.
34 35
19. UCE-9000 Turbo user’s manual
User may manually clean unit whenever desired.
Voice On/Off Selection Manual Cleaning Function
1 Press the upper part of LCD Screen. MENU 1 Press the upper part of LCD Screen.
Window appears below the upper part of MENU Window appears below the upper part
LCD Screen. of LCD Screen.
2 Select Voice icon. 2 Select CLEANING icon.
Manual Cleaning Function
Voice On/Off Selection
3 Whenever you press the voice icon 3 Cleaning mode is operated.
shortly, you can change in this sequence. [ cleaning time : 15 sec.]
36 37
20. UCE-9000 Turbo user’s manual
ECO Mode is a feature for saving power consumption during periods of non-use.
ECO MODE TURBO Function
The TURBO Function allows you to create strong alkaline and acidic water.
1 Press the upper part of LCD Screen. MENU These types of water are ONLY to be used for cleaning, sanitizing and
Window appears below the upper part of disinfecting purposes.
LCD Screen.
TURBO pH 2.5 Used to Disinfect
Strong Acidic Water ~ pH 3.8 and Sterilize
TURBO pH 10.0 To remove stains from
Strong Alkaline Water ~ pH 11.8 fabrics/carpet/upholstery.
2 Whenever you press the eco icon
shortly, you can change in this sequence.
3 When the ECO Mode is set,
TURBO Function
the LCD Screen isn’displayed anything.
t
Alkaline Turbo Water Outflow Acidic Turbo Water Outflow
ECO MODE
CAUTION!
The waters produced in TURBO mode are not intended for drinking.
If the Screen is pushed, it is changed into Standby DO NOT DRINK these types of waters.
Screen Mode. DO NOT Use the TURBO function in a manner other than directed.
38 39
21. UCE-9000 Turbo user’s manual
Recommendations for using this unit
Light Alkaline Water Medium Alkaline Water
Recommendations for using this unit
Recommendations for using this unit
Light Acidic Water Medium Acidic Water
(Drinking Level 1) (Drinking Level 2) (DO NOT DRINK) (DO NOT DRINK)
Suitable for initial stage of drinking. For making coffee, tea and for For washing hands, face. For washing vegetables and fruits.
watering plants.
Strong Alkaline Water Clean Water Strong Acidic Water TURBO Function
(Drinking Level 3) Creates purified water. For (DO NOT DRINK)
DO NOT DRINK. Strong acid/
For washing vegetables, dishes taking medications and making For washing dishes. alkaline water that must be used
and making rice. baby formula. when cleaning, disinfecting, washing
and sterilizing.
40 41
22. UCE-9000 Turbo user’s manual
Temperature Sensor Unit Specifications
1. Should water with a temperature
In flow higher than 95℉ (35℃) get into
Product Name Water Ionizer
the unit, the water supply will
automatically be shut off and the
unit will stop operating. Model Number UCE-9000 Turbo
4℃ or 35℃
2. LCD:
“TEMP ERROR” Purifying Mode TM Filtration Mode
Rated Power AC100V~AC130V, AC200~AC240V/50Hz~60Hz
Power Consumption Max. 374.4 VA
Available temperature 39º-95º F (4º-35º C)
Operating Pressure Range 0.1 ~ 0.5MPa
pH Levels 3 Alkaline, 1 Neutral, 3 Acidic, Turbo
Adjustable pH User adjustable pH levels control
Filters Configuration 2 Filters System
Filter Life Display LCD filter replacement and announcement
Hot Water Sensor
Unit Specifications
Electrolytic Cell Quantity of Poles 9
Water Cell Plate Materials Platinum and Titanium
Dispenser : 2(D) x 12.7(H) inches
Product Size
Ionizer : 14.1(W) x 5.2(D) x13.9(H) inches
Product Weight Dispenser : 1.1 Lbs / Ionizer : 15.2 Lbs