1. GSM Communicators
iGSMV/GSMV/iGSMHS GSMCF
G
GSMX GSMVLP GSMVLP5 VISTA-GSM SERVICE
Honeywell is focused on providing the best alarm communication This groundbreaking communications solution offers full data
solutions for the security industry. Alternative communication reporting and uploading/downloading with most Honeywell
methods are critical in the marketplace due to VoIP, migration control panels. In addition, with onboard zone inputs and
from POTS and global growth of digital networks. optional dialer capture capability, we’re compatible with
other manufacturers’ security panels as well. Honeywell
Honeywell’s Digital Cellular Communicators deliver secure,
communication products and control panels combine to
reliable and complementary digital communications via
make installations faster and easier.
the GSM (Global System for Mobile) network. Our use of
Dual-Path GPRS service with SMS backup provides substantial All signals are delivered to Honeywell’s AlarmNet® Network
benefits to protect your investment, helping to maintain and Control Center, which routes the information to the appropriate
grow your recurring revenue. central station. The state-of-the-art AlarmNet Network Control
Center is fully redundant and monitored 24/7. AlarmNet
has the ability to route messages using AlarmNet-i and
800 PLUS services, providing true redundancy and multi-path
message delivery.
FEATURES
• Full Contact ID or ADEMCO • Integration • Web-Based Programming
High-Speed Reporting Quick and easy installation of GSM Allows complete interactive
Contact ID reporting using ECP mode for VISTA and LYNX controls. programming from AlarmNet Direct.
with compatible Honeywell control https://services.alarmnet.com
• Dynamic Signaling with Certain
panels or combined with optional /AlarmnetDirect
Honeywell Control Panels
dialer capture for non-ECP capable
Provides management of control • Intelligent Supervision
control panels.
panel dialer and digital cellular Any message generated serves as
• 256-bit AES Encryption communicator. Programmable priority a supervision message per optional
Advanced encryption standard used and delays determine signal path. 24 hour or 30 day intervals. This
for secure communications. feature effectively limits required
• Diagnostic LEDs
messages to be sent.
• Dual-Path Technology Provide signal strength and status
Uses GPRS (General Packet Radio indications. • Remote Services Capability*
Service) as primary digital cellular Optional Total Connect value-added
• QOS
path and automatically switches web-based or SMS system control as
Quality of Service diagnostics via
to SMS (Short Message Service) well as e-mail notification of system
AlarmNet supply vital information
if GPRS is unavailable. events.
including when a message was
• Triple-Path Technology received, battery voltage, input • Two-Way Voice Transport
Provides three paths of communication voltage, signal strength and GSM voice channel capable to allow
using Internet, GPRS (General Packet message path. two-way voice session in conjunction
Radio Service), and SMS (Short with an audio verification system.
• Commercial Fire Communicator
Message Service). Uses Internet as (GSMX/iGSMV/GSMV/iGSMHS)
Code compliant fire communication
primary with dual GSM technology
approved to replace one or both • Line Security
as back-up. GSM path utilizes GPRS
phone lines (standalone) in Approved for line security applications
and automatically switches to SMS if
commercial fire applications. with 200-second supervision intervals.
GPRS is unavailable (iGSMV only).
See agency listings for details. (iGSMHS)
• Upload/Download
With select Honeywell control panels
using GPRS. Requires Compass
*Service subscription required.
version 1.5.8.54a or higher.
2. GSM Communicators
FEATURES
Features that apply to the iGSMV/GSMV and iGSMHS
• Universal Control Panel • Dialer Capture Ready • Tamper Protected Enclosure
Compatibility Compatible with Dialer Capture Built-in tamper sends a report when
Flexible modes of operation allow Intelligence Device DCID (for LYNX) a tamper condition is detected and
ECP alarm reporting by Honeywell or DCID-EXT (other control panels). a restore when cleared.
control panels, 4204 relay mode Captures Contact ID messages from
• Built-in Power Supply
for Honeywell controls (that do not the panel’s phone line and sends
Onboard charging circuit design
support ECP alarm reporting) and them to the central station via the
accommodates back-up battery.
zone triggering for use with other GSM radio (not agency approved).
Includes primary power and battery
control panels. (GSMV only) (GSMV only)
supervision.
• Six Input Zones
• Back-Up Battery
Digital processing for improved
6V 3.1Ah supplied to deliver up to
detection and false alarm protection
24 hours of standby operation.
SPECIFICATIONS
iGSMHS
Description • Current Drain: 35mA average Environmental
• Encrypted line security communication standby, 500mA peak transmit • Operating temperature:
Physical • Fault Relay Output: Open collector, -20º to 55º C
• Dimensions: 8.4" x 8.0" x 1.5" 12VDC, .25W max. • Storage temperature: -40º to 70º C
• Weight: 2.4 lbs. with battery • Input Trigger Levels: (V+) 6V – 13V; • Humidity: 0 to 95% relative humidity,
Electrical (V-) 0V – 1V non-condensing
• Input Power: 9VAC, 15VA transformer, RF • Altitude: to 10,000 ft. operating; to
Honeywell Model No. 1332 • Transceiver Type: Tri-Band GSM/ 40,000 ft. storage
• Backup Battery: 6V, 3.1AH, GPRS Class 10
Honeywell Part No. K14139, (included) • Modulation: GMSK
• Expected Battery Life: 5 years approx. • Antenna: Internal GSM quad-band
1.3dBi gain
GSMVLP (LYNX Plus only)/GSMVLP5 (LYNX Touch only)
Description Electrical Antenna
• Voice capable, quad band digital • Powered and battery backed directly • Quad Band: GSM 850, 900,
cellular communicator for use from L3000 Control 1800 & 1900
with L3000/L5000 series controls • Input Voltage: • VSWR: 3:1
• Uses an integrated quad band 10.5VDC nominal (GSMVLP) • Peak Gain: 3 dBi
antenna that eliminates the coaxial 5VDC nominal (GSMVLP5) • Impedance: 50 ohms
cable connections for a high reliability • Quiescent Current: • Polarization: linear
RF interface 40mA (GSMVLP)
Physical 15mA (GSMVLP5)
• Dimensions: • Average Current During Transmit:
5.5" x 2.5" (GSMVLP) 200mA (GSMVLP)
4.75" x 2.5" (GSMVLP5) 300mA (GSMVLP5)
GSMX
Description Electrical • Dialer Capture Ready: Compatible
• Quad band digital cellular • Input Voltage: 12VDC with Dialer Capture Intelligence
communicator for use with ECP (powered via the ECP bus) Device DCID (for LYNX) or DCID-EXT
capable Honeywell control panels • Standby Current: 30mA (other control panels). Captures
• Supports cabinet mount or may • Transmit Current: 200mA (Average) Contact ID messages from the
be remotely located • Transceiver Type: GSM/GPRS with panel’s phone line and sends them
Physical internal antenna to the central station via the GSM
radio (not agency approved).
• Dimensions: 4" x 7" x 1.75"
2
3. GSM Communicators
SPECIFICATIONS
VISTA-GSM
Physical VISTA-GSM Antenna • Polarization: Vertical
• Dimensions: 2.2" x 4.0" • Type: Dual band, dipole • Dimensions: 161mm x 26mm
Electrical • VSWR: <2:1 • Gain (Peak): 0-4 dBi
• Input Voltage: 4.1V • Bands: 824-896 MHz, • Connector Type: SMA male
• Peak Current During Transmit: 1.6A 1850-1990 MHz
• Quiescent Current: 20mA • Impedance: 50 ohms
*Standalone listing does not require a separate listed DACT.
Communications Device Agency Listings (U.S.) **Primary/backup listing requires use of a listed DACT.
Communication Testing
Devices Description Commercial Standards Residential Standards
Agency
UL1610
UL365 Police Central UL1635 Encrypted Line
Connected Station Digital Alarm Security California
Burglar Alarm UL609 Local Burglar Alarm Communications (Grade AA) UL864 State Fire UL1023 UL985
Commercial Burglar Alarm Commercial Commercial Commercial UL864 Primary/ Marshall Household Household
Burglar Systems Burglar Burglar Burglar Standalone* Backup** (CSFM) Burglar Alarm Fire
AlarmNet-G
Commercial Fire Kit
GSMCF (GSMV included)
UL/ETL 3 3 3 3 3 3 3 3
GSMV GSM Cellular (ETL Only) (UL Only) (ETL Only)
Communicator
Line Security
iGSMHS
Communicator
UL 3 3 3 3 3 3
GSM Communication
GSMVLP
Module for LYNX Plus
ETL 3 3 3
GSM Communication
GSMVLP5
Module for LYNX Touch
ETL 3 3 3
GSM Cellular
GSMX
Communicator
ETL 3 3 3
iGSMCF Internet/GSM Cellular
ETL
iGSMV Communicator 3 3 3 3 3 3
Snap-in GSM
VISTA-GSM Communication Module ETL 3 3 3 3 3 3 3
for VISTA-21iP Control
Communications Device Agency Listings (Canada)
Communication Description Testing Agency Canadian Standards
Devices
ULC-S304
ULC-S545
ULC-S303 Central and ULC/ORD-C1023
Residential Fire ULC-S559
Local Burglar Alarm Monitoring Station Household Burglar
Warning System
Burglar Alarm
AlarmNet-G
GSMCN cUL/ULC
GSM Cellular
Communicator
3 3 3 3 3
GSMVCN cETL
Snap-in GSM Communication
GSMLCN
Module for LYNX Control
ETL 3 3 3 3
GSM Communicator Module
GSMVLPCN
for LYNX Plus
ETL 3 3
GSM Communicator Module
GSMVLP5CN
for LYNX Touch
ETL 3 3
GSM Cellular
GSMXCN
Communicator
ETL 3 3
iGSMCN Internet/GSM Cellular
iGSMVCN Communicator
cUL/ULC 3 3 3 3 3
Snap-in GSM
VISTA-GSMCN Communication Module ETL 3 3 3 3
for VISTA-21iP Control
3