SlideShare a Scribd company logo
1 of 4
Download to read offline
SIMPLE INSTRUMENT MANAGEMENT THANKS TO DIGITAL COMMUNICATION 
With its HART® ability, the Dräger 
Polytron 8000 allows remote access using the Dräger PolySoft software for the quick and convenient evaluation of the instrument status. Integration in existing management systems (e.g. PactWare) is also possible using DTM. In addition, fieldbus systems such as Foundation Fieldbus or Profibus are supported by corresponding interfaces. 
PROVEN – AND STILL GETTING BETTER: DRÄGER MEASUREMENT TECHNOLOGY 
Dräger has been developing and manufacturing sensors and gas detectors for industrial use for more than 40 years. And with each new instrument generation, we drive our measurement technology a bit further. With the Polytron 8000, you will definitely benefit from this experience and power of innovation: 
––durable sensors 
––short response times 
––high sensitivity 
––high accuracy 
––low sensitivity to other gases or changing ambient conditions 
OPTIONAL: TWO MOUNTING SETS FOR EASY FLANGE-MOUNTING 
The housing has four mounting holes. Two different mounting sets are available for installing the Polytron 8000: a duct-mount and a pipe-mount set. This means that 
the transmitter can be easily installed 
anywhere – e.g., on a smooth wall, a pipe or an exhaust duct. 
Dräger Polytron 8000 
Stationary gas detector (EC) 
D-24180-2010 
The microprocessor-based transmitter can be equipped with various electrochemical DrägerSensors. This way, you can 
easily detect oxygen and various toxic gases in the ambient 
air. In addition, the Polytron 8000 can also be integrated into 
your digital fieldbus system, thus providing additional 
diagnostic functions. 
52603-2012 
D-52604-2012 
Dräger Polytron 8000 
Flameproof transmitter for monitoring toxic gases and oxygen. 
Same design, same operating principle: 
The Polytron 8000 series 
The Dräger Polytron 8000 is part of the Polytron 8000 series. All transmitters of this series have the same design and user interface, which guarantees a uniform operating philosophy. Your advantage: less training requirement and easier maintenance. 
Other transmitters of the Polytron 8000 series: 
– Dräger Polytron 8200 
(CatEx stationary gas detector) 
– Dräger Polytron 8310 
(DSIR stationary gas detector) 
– Dräger Polytron 8700 
(PIR 7000 stationary gas detector) 
– Dräger Polytron 8720 
(PIR 7200 stationary gas detector) 
Tel: +44 (0)191 490 1547 
Fax: +44 (0)191 477 5371 
Email: northernsales@thorneandderrick.co.uk 
Website: www.heattracing.co.uk www.thorneanderrick.co.uk
DRÄGER POLYTRON 8000 – STATIONARY GAS DETECTOR (EC) 
02 | 
Remote sensor terminals 
Relay terminals 
Power terminals 
Hinge pin 
Feed-through 
DRÄGER POLYTRON 8000 WITH 
E-BOX / DOCKING STATION ATTACHED 
OPTIONAL: THREE RELAYS FOR 
CONTROLLING EXTERNAL EQUIPMENT 
On request, the Dräger Polytron 8000 can be equipped with three integrated relays. This enables you to use it as an independent gas detection system with two arbitrarily adjustable concentration alarms and one fault alarm. Audio alarms, signal lights, or similar devices can, thus, be controlled locally – without an additional cable between the transmitter and a central 
controller. The sensor signal can be 
evaluated using the 4 to 20 mA signal. 
INTELLIGENT SENSORS 
The Dräger Polytron 8000 can detect over 100 different gases. DrägerSensors are specifically designed for the demands of 24 hours a day, 365 days per year operation. The large DrägerSensor size gives them their renowned long life and superior 
measurement performance. The integrated sensor memory contains all relevant sensor data. This also allows the Polytron 8000 to accept pre-calibrated sensors, the Dräger Polytron 8000 is a virtually maintenance- free transmitter. 
SOFTWARE OPTIONS 
With three different software dongles, a range of functions are incorporated into the transmitter adjusting it to user- or application-specific requirements. 
Sensor Test Dongle 
With this dongle, the Dräger Polytron 8000 performs many different patented sensor tests that ensure the reliability and functionality of the sensor and gas detection system. 
Sensor Diagnostic Dongle 
With the new sensor diagnostic function (including the sensor test), the stress and the remaining sensor life is evaluated so that maintenance and replacement cycles can be predicted and planned. 
Data Dongle 
Datalogger and eventlogger options are implemented in this dongle, which stores gas values and events such as faults and alarms. Using an IR interface, the data can be downloaded and evaluated on a PC using the Dräger PolySoft 8000 software package. Alternatively, a graphical 15 minute concentration history will be displayed on the transmitter screen, at the push of a button. 
FURTHER ADVANTAGES: 
––Easy and cost-effective: one-man calibration 
––Quick and easy wiring 
––Available as flameproof or increased safety version 
––Aluminium or 316 L stainless steel housing for the most extreme industrial conditions 
––Extremely user-friendly software thanks to a minimum number of menu items 
––Backlit display: easy to read, even in the dark and without a flash light 
––Traffic light status indicator 
(green = no danger, yellow = error, flashing red = gas alarm) 
––Intelligent sensors for predictive maintenance 
––Freely adjustable measuring ranges (within permitted ranges) 
––Matrix display allows the flexible setting of measuring ranges and units 
––SIL 2 certified by the German TÜV Süd 
D-15037-2010
DRÄGER POLYTRON 8000 – STATIONARY GAS DETECTOR (EC) 
| 03 
TECHNICAL DATA 
DRÄGER POLYTRON 8000 
Type Flameproof ‘d’ or combined increased safety ‘d/e’ transmitter 
Gases Toxic gases and oxygen (depending on the sensor used) 
Measuring ranges User adjustable (see sensor data sheet) 
Display Backlit graphic LCD; 3 status LEDs (green/yellow/red) 
Electrical data Analogue signal output Normal operation 4 to 20 mA 
Maintenance Steady 3.4 mA or 4 mA ± 1 mA 1 Hz modulation; 
user selectable 
Fault < 1.2 mA 
Digital signal output 
HART® 
Supply voltage 
10 to 30 V DC, 3-wire 
Relay rating 
2 alarm, 1 fault relay, SPDT 
(option) 
5 A @ 230 VAC, 5 A @ 30 VDC, resistive load 
Ambient conditions Temperature - 40 to + 150 °F / - 40 to + 65 °C 
(see also sensor data sheet) Pressure 20.7 to 38.4 inch Hg / 700 to 1300 mbar 
Humidity 
0 to 100% RH, non-condensing 
Enclosure Transmitter housing Epoxy-coated copper free aluminium 
or 316L stainless steel 
Sensor housing 
Polyamide 
Enclosure rating 
NEMA 4X & 7, IP 65/66/67 
Cable entry 
¾” NPT female conduit or M20 cable gland 
Size (l x w x d, approx.) without e-Box 11.0” x 5.9” x 5.1” / 280 x 150 x 130 mm 
with e-Box 11.0” x 7.1” x 7.5” / 280 x 180 x 190 mm 
Weight (approx.) without e-Box, 6.6 lbs / 3.0 kg 
aluminium 
without e-Box, 316 11.0 lbs / 5.0 kg 
stainless steel 
with e-Box, 9.9 lbs / 4.5 kg 
Aluminium 
with e-Box, 316 14.3 lbs / 6.5 kg 
stainless steel 
Approvals *) UL Class I, Div 1, Groups A, B, C, D; 
Class II, Div 1, Groups E, F, G 
Class I, Zone 1, Group IIC; T-Code T6 / T4 
CSA **) 
Class I, Div 1, Groups A, B, C, D; 
Class II, Div 1, Groups E, F, G 
Class I, Zone 1, Group IIC; T-Code T6 / T4 
IECEx 
Ex d [ia] IIC T6/T4 Gb, –40 ≤ Ta ≤ +40/+70 °C; 
‘d’ version 
Ex de [ia] IIC T6/T4 Gb, –40 ≤ Ta ≤ +40/+70 °C; 
‘e’ version; 
Ex tb [ia] IIIC T135 °C Db 
ATEX 
II 2G Ex d [ia] IIC T6/T4 Gb, –40 ≤ Ta ≤ +40/+70 °C; 
‘d’ version 
II 2G Ex de [ia] IIC T6/T4 Gb, –40 ≤ Ta ≤ +40/+70 °C; 
‘e’ version 
II 2D Ex tb [ia] IIIC T135 °C Db 
CE markings 
ATEX (Directive 94/9/EC) 
Electromagnetic Compatibility 
(Directive 2004/108/EC) 
Low Voltage (Directive 2006/95/EC) 
*) All e-Box versions are only ATEX / IECEx approved. 
**) Pending
ORDER INFORMATION 
DRÄGER POLYTRON 8000 
Aluminium ‘d’ 
SS316L ‘d’ Aluminium ‘e’ SS316L ‘e’ 
Without relays 45 44 403 45 44 412 45 44 421 *) 45 44 430 *) 
With relays 45 44 404 45 44 413 45 44 422 **) 45 44 431 **) 
*) Order e-Box 68 12 420 for power only wires separately. 
**) Order e-Box 68 12 275 for power and/or relay wires separately. 
Magnetic wand for menu access (blue body, white logo) 45 44 101 
e-Box Power only version (includes 1 cable gland) / Docking Station 68 12 420 
e-Box Power, Relay and/or Remote version 68 12 275 
(includes 2 cable glands) / Docking Station 
Cable Gland e-Box 68 12 868 
Sensor Test Dongle 83 17 619 
Diagnostic Dongle 83 17 860 
Data Dongle 83 17 618 
Combined Dongle (Data and Sensor Test Dongle) 83 23 218 
Combined Dongle (Data and Diagnostic Dongle) 83 23 219 
Pipe Mount Kit 45 44 198 
Duct Mount Kit 68 12 725 
Duct Mount Adapter for Remote EC Sensing Head 83 17 617 
EC Sensing Head Remote w/ mount kit 68 12 684 
MEC Sensor Adapter Polytron 5000/8000 68 12 695 
IR Connection Kit Polytron 5000/8000 45 44 197 
PolySoft 8000 83 23 405 PolySoft 8000 premium 83 23 411 
Connection cable w/ plug 
for Remote EC Sensing Head 16 ft / 5 m 83 23 305 49 ft / 15 m 83 23 315 98 ft / 30 m 83 23 330 
DrägerSensors 
Acidic Compounds AC 68 10 595 H2O2 HC 68 09 675 PH3/AsH3 68 09 695 NO2 68 09 655 
Cl2 68 09 665 H2O2 LC 68 09 705 Hydride 68 09 635 O2 68 09 720 
CO 68 09 605 H2S 68 10 435 Hydride SC 68 09 980 O2 LS 68 09 630 
CO LS 68 09 620 H2S HC 68 09 710 N2H4 68 10 180 O3 68 10 290 
CO LH 68 12 570 H2S LC 68 09 610 NH3 HC 68 09 645 OV1 68 10 740 
COCl2 68 09 930 HCl 68 09 640 NH3 LC 68 09 680 OV2 68 10 745 
H2 68 09 685 HCN 68 09 650 NO LC 68 09 625 SO2 68 09 660 
Accessories 
Splash guard 68 12 510 
Calibration Adapter PE, Europe 68 06 978 PE 45 09 314 
Calibration Adapter Viton 68 10 536 
DRÄGER POLYTRON 8000 – STATIONARY GAS DETECTOR (EC) 
04 | 
90 41 533 | 09.12-1 | Marketing Communications | PP | PR | LE | Printed in Germany | Chlorine-free – environmentally compatible | Subject to modifications | © 2012 Drägerwerk AG & Co. KGaA 
Tel: +44 (0)191 490 1547 
Fax: +44 (0)191 477 5371 
Email: northernsales@thorneandderrick.co.uk 
Website: www.heattracing.co.uk www.thorneanderrick.co.uk

More Related Content

What's hot

Ngen oss bss - architecture evolution
Ngen oss bss - architecture evolution Ngen oss bss - architecture evolution
Ngen oss bss - architecture evolution Grazio Panico
 
PLNOG 22 - Aleksandra Chećko, Robert Cieloch - 5G: wydatek czy oszczędność?
PLNOG 22 - Aleksandra Chećko, Robert Cieloch - 5G: wydatek czy oszczędność?PLNOG 22 - Aleksandra Chećko, Robert Cieloch - 5G: wydatek czy oszczędność?
PLNOG 22 - Aleksandra Chećko, Robert Cieloch - 5G: wydatek czy oszczędność?PROIDEA
 
Foundation fieldbus technology
Foundation fieldbus technologyFoundation fieldbus technology
Foundation fieldbus technologyMohamed A Hakim
 
Katherine 80010606 v01
Katherine 80010606 v01Katherine 80010606 v01
Katherine 80010606 v01Azam Khan
 
OTDR OPERATION BASICS
OTDR OPERATION BASICSOTDR OPERATION BASICS
OTDR OPERATION BASICSimtfiber
 
VoLTE Interfaces , Protocols & IMS Stack Explained
VoLTE Interfaces , Protocols & IMS Stack ExplainedVoLTE Interfaces , Protocols & IMS Stack Explained
VoLTE Interfaces , Protocols & IMS Stack ExplainedVikas Shokeen
 
5G - Tech to business case
5G - Tech to business case5G - Tech to business case
5G - Tech to business case3G4G
 
Ethernet Over Dwdm Whitepaper
Ethernet Over Dwdm WhitepaperEthernet Over Dwdm Whitepaper
Ethernet Over Dwdm WhitepaperSarmad Saleem Gul
 
4G to 5G Evolution
4G to 5G Evolution4G to 5G Evolution
4G to 5G EvolutionManoj Singh
 
Lte project report
Lte project reportLte project report
Lte project reportRahul Kumar
 
Beginners: TCO of a Mobile Network
Beginners: TCO of a Mobile NetworkBeginners: TCO of a Mobile Network
Beginners: TCO of a Mobile Network3G4G
 
Synchronization for 5G Deployments
Synchronization for 5G DeploymentsSynchronization for 5G Deployments
Synchronization for 5G DeploymentsDhiman Chowdhury
 
Optical Transport Technologies and Trends
Optical Transport Technologies and TrendsOptical Transport Technologies and Trends
Optical Transport Technologies and TrendsMyNOG
 
Rocla concrete pole_guide_2010
Rocla concrete pole_guide_2010Rocla concrete pole_guide_2010
Rocla concrete pole_guide_2010fabriciomgomes
 
5G positioning for the connected intelligent edge
5G positioning for the connected intelligent edge5G positioning for the connected intelligent edge
5G positioning for the connected intelligent edgeQualcomm Research
 
Implementation of OSS/BSS Solution in IoT Ecosystem
Implementation of OSS/BSS Solution in IoT EcosystemImplementation of OSS/BSS Solution in IoT Ecosystem
Implementation of OSS/BSS Solution in IoT EcosystemVishal Kumar
 

What's hot (20)

Ngen oss bss - architecture evolution
Ngen oss bss - architecture evolution Ngen oss bss - architecture evolution
Ngen oss bss - architecture evolution
 
PLNOG 22 - Aleksandra Chećko, Robert Cieloch - 5G: wydatek czy oszczędność?
PLNOG 22 - Aleksandra Chećko, Robert Cieloch - 5G: wydatek czy oszczędność?PLNOG 22 - Aleksandra Chećko, Robert Cieloch - 5G: wydatek czy oszczędność?
PLNOG 22 - Aleksandra Chećko, Robert Cieloch - 5G: wydatek czy oszczędność?
 
Foundation fieldbus technology
Foundation fieldbus technologyFoundation fieldbus technology
Foundation fieldbus technology
 
Katherine 80010606 v01
Katherine 80010606 v01Katherine 80010606 v01
Katherine 80010606 v01
 
Drive Test Nemo
Drive Test NemoDrive Test Nemo
Drive Test Nemo
 
OTDR OPERATION BASICS
OTDR OPERATION BASICSOTDR OPERATION BASICS
OTDR OPERATION BASICS
 
Ofdm
OfdmOfdm
Ofdm
 
VoLTE Interfaces , Protocols & IMS Stack Explained
VoLTE Interfaces , Protocols & IMS Stack ExplainedVoLTE Interfaces , Protocols & IMS Stack Explained
VoLTE Interfaces , Protocols & IMS Stack Explained
 
5G - Tech to business case
5G - Tech to business case5G - Tech to business case
5G - Tech to business case
 
Ethernet Over Dwdm Whitepaper
Ethernet Over Dwdm WhitepaperEthernet Over Dwdm Whitepaper
Ethernet Over Dwdm Whitepaper
 
4G to 5G Evolution
4G to 5G Evolution4G to 5G Evolution
4G to 5G Evolution
 
Emerson DeltaV Control Network
Emerson DeltaV Control NetworkEmerson DeltaV Control Network
Emerson DeltaV Control Network
 
Lte project report
Lte project reportLte project report
Lte project report
 
Beginners: TCO of a Mobile Network
Beginners: TCO of a Mobile NetworkBeginners: TCO of a Mobile Network
Beginners: TCO of a Mobile Network
 
Synchronization for 5G Deployments
Synchronization for 5G DeploymentsSynchronization for 5G Deployments
Synchronization for 5G Deployments
 
Optical Transport Technologies and Trends
Optical Transport Technologies and TrendsOptical Transport Technologies and Trends
Optical Transport Technologies and Trends
 
Rocla concrete pole_guide_2010
Rocla concrete pole_guide_2010Rocla concrete pole_guide_2010
Rocla concrete pole_guide_2010
 
5G Network Overview
 5G Network Overview 5G Network Overview
5G Network Overview
 
5G positioning for the connected intelligent edge
5G positioning for the connected intelligent edge5G positioning for the connected intelligent edge
5G positioning for the connected intelligent edge
 
Implementation of OSS/BSS Solution in IoT Ecosystem
Implementation of OSS/BSS Solution in IoT EcosystemImplementation of OSS/BSS Solution in IoT Ecosystem
Implementation of OSS/BSS Solution in IoT Ecosystem
 

Similar to Drager Polytron 8000 Fixed Gas Detector - Spec Sheet

Drager Polytron 8200 Fixed Gas Detector - Spec Sheet
Drager Polytron 8200 Fixed Gas Detector - Spec SheetDrager Polytron 8200 Fixed Gas Detector - Spec Sheet
Drager Polytron 8200 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Drager Polytron 5200 Fixed Gas Detector - Spec Sheet
Drager Polytron 5200 Fixed Gas Detector - Spec SheetDrager Polytron 5200 Fixed Gas Detector - Spec Sheet
Drager Polytron 5200 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Drager Polytron 8310 Fixed Gas Detector - Spec Sheet
Drager Polytron 8310 Fixed Gas Detector - Spec SheetDrager Polytron 8310 Fixed Gas Detector - Spec Sheet
Drager Polytron 8310 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Drager Polytron 8700 Fixed Gas Detector - Spec Sheet
Drager Polytron 8700 Fixed Gas Detector - Spec SheetDrager Polytron 8700 Fixed Gas Detector - Spec Sheet
Drager Polytron 8700 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Dräger Polytron 8700 Fixed Gas Detector - Spec Sheet
Dräger Polytron 8700 Fixed Gas Detector - Spec SheetDräger Polytron 8700 Fixed Gas Detector - Spec Sheet
Dräger Polytron 8700 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Drager Polytron 5720 Fixed Gas Detector - Spec Sheet
Drager Polytron 5720 Fixed Gas Detector - Spec SheetDrager Polytron 5720 Fixed Gas Detector - Spec Sheet
Drager Polytron 5720 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Drager Polytron 8720 Fixed Gas Detector - Spec Sheet
Drager Polytron 8720 Fixed Gas Detector - Spec SheetDrager Polytron 8720 Fixed Gas Detector - Spec Sheet
Drager Polytron 8720 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Drager Polytron 5700 Fixed Gas Detector - Spec Sheet
Drager Polytron 5700 Fixed Gas Detector - Spec SheetDrager Polytron 5700 Fixed Gas Detector - Spec Sheet
Drager Polytron 5700 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Drager Polytron 5310 Fixed Gas Detector - Spec Sheet
Drager Polytron 5310 Fixed Gas Detector - Spec SheetDrager Polytron 5310 Fixed Gas Detector - Spec Sheet
Drager Polytron 5310 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Drager Polytron 7000 Fixed Gas Detector - Spec Sheet
Drager Polytron 7000 Fixed Gas Detector - Spec SheetDrager Polytron 7000 Fixed Gas Detector - Spec Sheet
Drager Polytron 7000 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Drager Polytron 5000 Fixed Gas Detector - Spec Sheet
Drager Polytron 5000 Fixed Gas Detector - Spec SheetDrager Polytron 5000 Fixed Gas Detector - Spec Sheet
Drager Polytron 5000 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Drager Polytron 7500 Fixed Gas Detector - Spec Sheet
Drager Polytron 7500 Fixed Gas Detector - Spec SheetDrager Polytron 7500 Fixed Gas Detector - Spec Sheet
Drager Polytron 7500 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Drager Polytron 3000 Fixed Gas Detector - Spec Sheet
Drager Polytron 3000 Fixed Gas Detector - Spec SheetDrager Polytron 3000 Fixed Gas Detector - Spec Sheet
Drager Polytron 3000 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Drager Polytron IR Fixed Gas Detector - Spec Sheet
Drager Polytron IR Fixed Gas Detector  - Spec SheetDrager Polytron IR Fixed Gas Detector  - Spec Sheet
Drager Polytron IR Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Draeger Pacific Fire & Gas Solutions
Draeger Pacific Fire & Gas SolutionsDraeger Pacific Fire & Gas Solutions
Draeger Pacific Fire & Gas SolutionsPreeju Anirudhan
 
Drager PointGard 2000 Series Gas Detection System
Drager PointGard 2000 Series Gas Detection SystemDrager PointGard 2000 Series Gas Detection System
Drager PointGard 2000 Series Gas Detection SystemFlow-Tech, Inc.
 
GCEM 40 series gas analyser insitu-codel datasheet
GCEM 40 series gas analyser insitu-codel datasheetGCEM 40 series gas analyser insitu-codel datasheet
GCEM 40 series gas analyser insitu-codel datasheetENVIMART
 
Labguard 3D Technical brochure
Labguard 3D Technical brochureLabguard 3D Technical brochure
Labguard 3D Technical brochureNestor Martinez
 
Drager Pac 3500 Portable Gas Detector - Spec Sheet
Drager Pac 3500 Portable Gas Detector - Spec SheetDrager Pac 3500 Portable Gas Detector - Spec Sheet
Drager Pac 3500 Portable Gas Detector - Spec SheetThorne & Derrick UK
 
Drager Variogard 3200 CAT Fixed Gas Detector - Spec Sheet
Drager Variogard 3200 CAT Fixed Gas Detector - Spec SheetDrager Variogard 3200 CAT Fixed Gas Detector - Spec Sheet
Drager Variogard 3200 CAT Fixed Gas Detector - Spec SheetThorne & Derrick UK
 

Similar to Drager Polytron 8000 Fixed Gas Detector - Spec Sheet (20)

Drager Polytron 8200 Fixed Gas Detector - Spec Sheet
Drager Polytron 8200 Fixed Gas Detector - Spec SheetDrager Polytron 8200 Fixed Gas Detector - Spec Sheet
Drager Polytron 8200 Fixed Gas Detector - Spec Sheet
 
Drager Polytron 5200 Fixed Gas Detector - Spec Sheet
Drager Polytron 5200 Fixed Gas Detector - Spec SheetDrager Polytron 5200 Fixed Gas Detector - Spec Sheet
Drager Polytron 5200 Fixed Gas Detector - Spec Sheet
 
Drager Polytron 8310 Fixed Gas Detector - Spec Sheet
Drager Polytron 8310 Fixed Gas Detector - Spec SheetDrager Polytron 8310 Fixed Gas Detector - Spec Sheet
Drager Polytron 8310 Fixed Gas Detector - Spec Sheet
 
Drager Polytron 8700 Fixed Gas Detector - Spec Sheet
Drager Polytron 8700 Fixed Gas Detector - Spec SheetDrager Polytron 8700 Fixed Gas Detector - Spec Sheet
Drager Polytron 8700 Fixed Gas Detector - Spec Sheet
 
Dräger Polytron 8700 Fixed Gas Detector - Spec Sheet
Dräger Polytron 8700 Fixed Gas Detector - Spec SheetDräger Polytron 8700 Fixed Gas Detector - Spec Sheet
Dräger Polytron 8700 Fixed Gas Detector - Spec Sheet
 
Drager Polytron 5720 Fixed Gas Detector - Spec Sheet
Drager Polytron 5720 Fixed Gas Detector - Spec SheetDrager Polytron 5720 Fixed Gas Detector - Spec Sheet
Drager Polytron 5720 Fixed Gas Detector - Spec Sheet
 
Drager Polytron 8720 Fixed Gas Detector - Spec Sheet
Drager Polytron 8720 Fixed Gas Detector - Spec SheetDrager Polytron 8720 Fixed Gas Detector - Spec Sheet
Drager Polytron 8720 Fixed Gas Detector - Spec Sheet
 
Drager Polytron 5700 Fixed Gas Detector - Spec Sheet
Drager Polytron 5700 Fixed Gas Detector - Spec SheetDrager Polytron 5700 Fixed Gas Detector - Spec Sheet
Drager Polytron 5700 Fixed Gas Detector - Spec Sheet
 
Drager Polytron 5310 Fixed Gas Detector - Spec Sheet
Drager Polytron 5310 Fixed Gas Detector - Spec SheetDrager Polytron 5310 Fixed Gas Detector - Spec Sheet
Drager Polytron 5310 Fixed Gas Detector - Spec Sheet
 
Drager Polytron 7000 Fixed Gas Detector - Spec Sheet
Drager Polytron 7000 Fixed Gas Detector - Spec SheetDrager Polytron 7000 Fixed Gas Detector - Spec Sheet
Drager Polytron 7000 Fixed Gas Detector - Spec Sheet
 
Drager Polytron 5000 Fixed Gas Detector - Spec Sheet
Drager Polytron 5000 Fixed Gas Detector - Spec SheetDrager Polytron 5000 Fixed Gas Detector - Spec Sheet
Drager Polytron 5000 Fixed Gas Detector - Spec Sheet
 
Drager Polytron 7500 Fixed Gas Detector - Spec Sheet
Drager Polytron 7500 Fixed Gas Detector - Spec SheetDrager Polytron 7500 Fixed Gas Detector - Spec Sheet
Drager Polytron 7500 Fixed Gas Detector - Spec Sheet
 
Drager Polytron 3000 Fixed Gas Detector - Spec Sheet
Drager Polytron 3000 Fixed Gas Detector - Spec SheetDrager Polytron 3000 Fixed Gas Detector - Spec Sheet
Drager Polytron 3000 Fixed Gas Detector - Spec Sheet
 
Drager Polytron IR Fixed Gas Detector - Spec Sheet
Drager Polytron IR Fixed Gas Detector  - Spec SheetDrager Polytron IR Fixed Gas Detector  - Spec Sheet
Drager Polytron IR Fixed Gas Detector - Spec Sheet
 
Draeger Pacific Fire & Gas Solutions
Draeger Pacific Fire & Gas SolutionsDraeger Pacific Fire & Gas Solutions
Draeger Pacific Fire & Gas Solutions
 
Drager PointGard 2000 Series Gas Detection System
Drager PointGard 2000 Series Gas Detection SystemDrager PointGard 2000 Series Gas Detection System
Drager PointGard 2000 Series Gas Detection System
 
GCEM 40 series gas analyser insitu-codel datasheet
GCEM 40 series gas analyser insitu-codel datasheetGCEM 40 series gas analyser insitu-codel datasheet
GCEM 40 series gas analyser insitu-codel datasheet
 
Labguard 3D Technical brochure
Labguard 3D Technical brochureLabguard 3D Technical brochure
Labguard 3D Technical brochure
 
Drager Pac 3500 Portable Gas Detector - Spec Sheet
Drager Pac 3500 Portable Gas Detector - Spec SheetDrager Pac 3500 Portable Gas Detector - Spec Sheet
Drager Pac 3500 Portable Gas Detector - Spec Sheet
 
Drager Variogard 3200 CAT Fixed Gas Detector - Spec Sheet
Drager Variogard 3200 CAT Fixed Gas Detector - Spec SheetDrager Variogard 3200 CAT Fixed Gas Detector - Spec Sheet
Drager Variogard 3200 CAT Fixed Gas Detector - Spec Sheet
 

More from Thorne & Derrick UK

Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...
Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...
Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...Thorne & Derrick UK
 
Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...
Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...
Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...Thorne & Derrick UK
 
Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2016
Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2016Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2016
Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2016Thorne & Derrick UK
 
Wolf - Hazardous Area Portable & Temporary Lighting - Brochure
Wolf - Hazardous Area Portable & Temporary Lighting - BrochureWolf - Hazardous Area Portable & Temporary Lighting - Brochure
Wolf - Hazardous Area Portable & Temporary Lighting - BrochureThorne & Derrick UK
 
VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...
VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...
VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...Thorne & Derrick UK
 
Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...
Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...
Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...Thorne & Derrick UK
 
SIRAI - Solenoid Valves (WRAS Approved) - Overview Catalogue
SIRAI - Solenoid Valves (WRAS Approved) - Overview CatalogueSIRAI - Solenoid Valves (WRAS Approved) - Overview Catalogue
SIRAI - Solenoid Valves (WRAS Approved) - Overview CatalogueThorne & Derrick UK
 
Sika Measuring Metering Calibration Instruments
Sika Measuring Metering Calibration InstrumentsSika Measuring Metering Calibration Instruments
Sika Measuring Metering Calibration InstrumentsThorne & Derrick UK
 
SICK - Sensors & Sensor Solutions - Catalogue
SICK - Sensors & Sensor Solutions - CatalogueSICK - Sensors & Sensor Solutions - Catalogue
SICK - Sensors & Sensor Solutions - CatalogueThorne & Derrick UK
 
Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...
Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...
Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...Thorne & Derrick UK
 
Patol Analogue Linear Heat Detection Cable
Patol Analogue Linear Heat Detection CablePatol Analogue Linear Heat Detection Cable
Patol Analogue Linear Heat Detection CableThorne & Derrick UK
 
Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...
Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...
Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...Thorne & Derrick UK
 
MSA Gas Detectors – Portable & Fixed Gas Detection - Brochure
MSA Gas Detectors – Portable & Fixed Gas Detection - BrochureMSA Gas Detectors – Portable & Fixed Gas Detection - Brochure
MSA Gas Detectors – Portable & Fixed Gas Detection - BrochureThorne & Derrick UK
 
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp On
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp OnFlow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp On
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp OnThorne & Derrick UK
 
LMK Thermosafe Hazardous Area Drum & IBC Product Overview
LMK Thermosafe Hazardous Area Drum & IBC Product OverviewLMK Thermosafe Hazardous Area Drum & IBC Product Overview
LMK Thermosafe Hazardous Area Drum & IBC Product OverviewThorne & Derrick UK
 
Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...
Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...
Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...Thorne & Derrick UK
 
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product Brochure
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product BrochureKatronic - Ultrasonic Flow Measurement & Flowmeters - Product Brochure
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product BrochureThorne & Derrick UK
 
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...Thorne & Derrick UK
 
Itron - Gas, Water & Heat Meters - Corporate Brochure
Itron - Gas, Water & Heat Meters - Corporate BrochureItron - Gas, Water & Heat Meters - Corporate Brochure
Itron - Gas, Water & Heat Meters - Corporate BrochureThorne & Derrick UK
 

More from Thorne & Derrick UK (20)

Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...
Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...
Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...
 
Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...
Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...
Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...
 
Dart Valley Systems Catalogue
Dart Valley Systems CatalogueDart Valley Systems Catalogue
Dart Valley Systems Catalogue
 
Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2016
Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2016Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2016
Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2016
 
Wolf - Hazardous Area Portable & Temporary Lighting - Brochure
Wolf - Hazardous Area Portable & Temporary Lighting - BrochureWolf - Hazardous Area Portable & Temporary Lighting - Brochure
Wolf - Hazardous Area Portable & Temporary Lighting - Brochure
 
VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...
VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...
VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...
 
Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...
Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...
Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...
 
SIRAI - Solenoid Valves (WRAS Approved) - Overview Catalogue
SIRAI - Solenoid Valves (WRAS Approved) - Overview CatalogueSIRAI - Solenoid Valves (WRAS Approved) - Overview Catalogue
SIRAI - Solenoid Valves (WRAS Approved) - Overview Catalogue
 
Sika Measuring Metering Calibration Instruments
Sika Measuring Metering Calibration InstrumentsSika Measuring Metering Calibration Instruments
Sika Measuring Metering Calibration Instruments
 
SICK - Sensors & Sensor Solutions - Catalogue
SICK - Sensors & Sensor Solutions - CatalogueSICK - Sensors & Sensor Solutions - Catalogue
SICK - Sensors & Sensor Solutions - Catalogue
 
Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...
Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...
Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...
 
Patol Analogue Linear Heat Detection Cable
Patol Analogue Linear Heat Detection CablePatol Analogue Linear Heat Detection Cable
Patol Analogue Linear Heat Detection Cable
 
Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...
Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...
Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...
 
MSA Gas Detectors – Portable & Fixed Gas Detection - Brochure
MSA Gas Detectors – Portable & Fixed Gas Detection - BrochureMSA Gas Detectors – Portable & Fixed Gas Detection - Brochure
MSA Gas Detectors – Portable & Fixed Gas Detection - Brochure
 
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp On
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp OnFlow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp On
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp On
 
LMK Thermosafe Hazardous Area Drum & IBC Product Overview
LMK Thermosafe Hazardous Area Drum & IBC Product OverviewLMK Thermosafe Hazardous Area Drum & IBC Product Overview
LMK Thermosafe Hazardous Area Drum & IBC Product Overview
 
Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...
Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...
Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...
 
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product Brochure
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product BrochureKatronic - Ultrasonic Flow Measurement & Flowmeters - Product Brochure
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product Brochure
 
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...
 
Itron - Gas, Water & Heat Meters - Corporate Brochure
Itron - Gas, Water & Heat Meters - Corporate BrochureItron - Gas, Water & Heat Meters - Corporate Brochure
Itron - Gas, Water & Heat Meters - Corporate Brochure
 

Recently uploaded

A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)Gabriella Davis
 
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptxFactors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptxKatpro Technologies
 
Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024The Digital Insurer
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsMaria Levchenko
 
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking MenDelhi Call girls
 
CNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of ServiceCNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of Servicegiselly40
 
Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024The Digital Insurer
 
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...apidays
 
Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Enterprise Knowledge
 
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptxEIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptxEarley Information Science
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024The Digital Insurer
 
The Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxThe Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxMalak Abu Hammad
 
Real Time Object Detection Using Open CV
Real Time Object Detection Using Open CVReal Time Object Detection Using Open CV
Real Time Object Detection Using Open CVKhem
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...Martijn de Jong
 
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...Igalia
 
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdfThe Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdfEnterprise Knowledge
 
Presentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreterPresentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreternaman860154
 
Boost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfBoost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfsudhanshuwaghmare1
 
IAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI SolutionsIAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI SolutionsEnterprise Knowledge
 
08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking MenDelhi Call girls
 

Recently uploaded (20)

A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)
 
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptxFactors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
 
Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed texts
 
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
 
CNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of ServiceCNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of Service
 
Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024
 
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
 
Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...
 
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptxEIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024
 
The Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxThe Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptx
 
Real Time Object Detection Using Open CV
Real Time Object Detection Using Open CVReal Time Object Detection Using Open CV
Real Time Object Detection Using Open CV
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...
 
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
 
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdfThe Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
 
Presentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreterPresentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreter
 
Boost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfBoost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdf
 
IAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI SolutionsIAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI Solutions
 
08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men
 

Drager Polytron 8000 Fixed Gas Detector - Spec Sheet

  • 1. SIMPLE INSTRUMENT MANAGEMENT THANKS TO DIGITAL COMMUNICATION With its HART® ability, the Dräger Polytron 8000 allows remote access using the Dräger PolySoft software for the quick and convenient evaluation of the instrument status. Integration in existing management systems (e.g. PactWare) is also possible using DTM. In addition, fieldbus systems such as Foundation Fieldbus or Profibus are supported by corresponding interfaces. PROVEN – AND STILL GETTING BETTER: DRÄGER MEASUREMENT TECHNOLOGY Dräger has been developing and manufacturing sensors and gas detectors for industrial use for more than 40 years. And with each new instrument generation, we drive our measurement technology a bit further. With the Polytron 8000, you will definitely benefit from this experience and power of innovation: ––durable sensors ––short response times ––high sensitivity ––high accuracy ––low sensitivity to other gases or changing ambient conditions OPTIONAL: TWO MOUNTING SETS FOR EASY FLANGE-MOUNTING The housing has four mounting holes. Two different mounting sets are available for installing the Polytron 8000: a duct-mount and a pipe-mount set. This means that the transmitter can be easily installed anywhere – e.g., on a smooth wall, a pipe or an exhaust duct. Dräger Polytron 8000 Stationary gas detector (EC) D-24180-2010 The microprocessor-based transmitter can be equipped with various electrochemical DrägerSensors. This way, you can easily detect oxygen and various toxic gases in the ambient air. In addition, the Polytron 8000 can also be integrated into your digital fieldbus system, thus providing additional diagnostic functions. 52603-2012 D-52604-2012 Dräger Polytron 8000 Flameproof transmitter for monitoring toxic gases and oxygen. Same design, same operating principle: The Polytron 8000 series The Dräger Polytron 8000 is part of the Polytron 8000 series. All transmitters of this series have the same design and user interface, which guarantees a uniform operating philosophy. Your advantage: less training requirement and easier maintenance. Other transmitters of the Polytron 8000 series: – Dräger Polytron 8200 (CatEx stationary gas detector) – Dräger Polytron 8310 (DSIR stationary gas detector) – Dräger Polytron 8700 (PIR 7000 stationary gas detector) – Dräger Polytron 8720 (PIR 7200 stationary gas detector) Tel: +44 (0)191 490 1547 Fax: +44 (0)191 477 5371 Email: northernsales@thorneandderrick.co.uk Website: www.heattracing.co.uk www.thorneanderrick.co.uk
  • 2. DRÄGER POLYTRON 8000 – STATIONARY GAS DETECTOR (EC) 02 | Remote sensor terminals Relay terminals Power terminals Hinge pin Feed-through DRÄGER POLYTRON 8000 WITH E-BOX / DOCKING STATION ATTACHED OPTIONAL: THREE RELAYS FOR CONTROLLING EXTERNAL EQUIPMENT On request, the Dräger Polytron 8000 can be equipped with three integrated relays. This enables you to use it as an independent gas detection system with two arbitrarily adjustable concentration alarms and one fault alarm. Audio alarms, signal lights, or similar devices can, thus, be controlled locally – without an additional cable between the transmitter and a central controller. The sensor signal can be evaluated using the 4 to 20 mA signal. INTELLIGENT SENSORS The Dräger Polytron 8000 can detect over 100 different gases. DrägerSensors are specifically designed for the demands of 24 hours a day, 365 days per year operation. The large DrägerSensor size gives them their renowned long life and superior measurement performance. The integrated sensor memory contains all relevant sensor data. This also allows the Polytron 8000 to accept pre-calibrated sensors, the Dräger Polytron 8000 is a virtually maintenance- free transmitter. SOFTWARE OPTIONS With three different software dongles, a range of functions are incorporated into the transmitter adjusting it to user- or application-specific requirements. Sensor Test Dongle With this dongle, the Dräger Polytron 8000 performs many different patented sensor tests that ensure the reliability and functionality of the sensor and gas detection system. Sensor Diagnostic Dongle With the new sensor diagnostic function (including the sensor test), the stress and the remaining sensor life is evaluated so that maintenance and replacement cycles can be predicted and planned. Data Dongle Datalogger and eventlogger options are implemented in this dongle, which stores gas values and events such as faults and alarms. Using an IR interface, the data can be downloaded and evaluated on a PC using the Dräger PolySoft 8000 software package. Alternatively, a graphical 15 minute concentration history will be displayed on the transmitter screen, at the push of a button. FURTHER ADVANTAGES: ––Easy and cost-effective: one-man calibration ––Quick and easy wiring ––Available as flameproof or increased safety version ––Aluminium or 316 L stainless steel housing for the most extreme industrial conditions ––Extremely user-friendly software thanks to a minimum number of menu items ––Backlit display: easy to read, even in the dark and without a flash light ––Traffic light status indicator (green = no danger, yellow = error, flashing red = gas alarm) ––Intelligent sensors for predictive maintenance ––Freely adjustable measuring ranges (within permitted ranges) ––Matrix display allows the flexible setting of measuring ranges and units ––SIL 2 certified by the German TÜV Süd D-15037-2010
  • 3. DRÄGER POLYTRON 8000 – STATIONARY GAS DETECTOR (EC) | 03 TECHNICAL DATA DRÄGER POLYTRON 8000 Type Flameproof ‘d’ or combined increased safety ‘d/e’ transmitter Gases Toxic gases and oxygen (depending on the sensor used) Measuring ranges User adjustable (see sensor data sheet) Display Backlit graphic LCD; 3 status LEDs (green/yellow/red) Electrical data Analogue signal output Normal operation 4 to 20 mA Maintenance Steady 3.4 mA or 4 mA ± 1 mA 1 Hz modulation; user selectable Fault < 1.2 mA Digital signal output HART® Supply voltage 10 to 30 V DC, 3-wire Relay rating 2 alarm, 1 fault relay, SPDT (option) 5 A @ 230 VAC, 5 A @ 30 VDC, resistive load Ambient conditions Temperature - 40 to + 150 °F / - 40 to + 65 °C (see also sensor data sheet) Pressure 20.7 to 38.4 inch Hg / 700 to 1300 mbar Humidity 0 to 100% RH, non-condensing Enclosure Transmitter housing Epoxy-coated copper free aluminium or 316L stainless steel Sensor housing Polyamide Enclosure rating NEMA 4X & 7, IP 65/66/67 Cable entry ¾” NPT female conduit or M20 cable gland Size (l x w x d, approx.) without e-Box 11.0” x 5.9” x 5.1” / 280 x 150 x 130 mm with e-Box 11.0” x 7.1” x 7.5” / 280 x 180 x 190 mm Weight (approx.) without e-Box, 6.6 lbs / 3.0 kg aluminium without e-Box, 316 11.0 lbs / 5.0 kg stainless steel with e-Box, 9.9 lbs / 4.5 kg Aluminium with e-Box, 316 14.3 lbs / 6.5 kg stainless steel Approvals *) UL Class I, Div 1, Groups A, B, C, D; Class II, Div 1, Groups E, F, G Class I, Zone 1, Group IIC; T-Code T6 / T4 CSA **) Class I, Div 1, Groups A, B, C, D; Class II, Div 1, Groups E, F, G Class I, Zone 1, Group IIC; T-Code T6 / T4 IECEx Ex d [ia] IIC T6/T4 Gb, –40 ≤ Ta ≤ +40/+70 °C; ‘d’ version Ex de [ia] IIC T6/T4 Gb, –40 ≤ Ta ≤ +40/+70 °C; ‘e’ version; Ex tb [ia] IIIC T135 °C Db ATEX II 2G Ex d [ia] IIC T6/T4 Gb, –40 ≤ Ta ≤ +40/+70 °C; ‘d’ version II 2G Ex de [ia] IIC T6/T4 Gb, –40 ≤ Ta ≤ +40/+70 °C; ‘e’ version II 2D Ex tb [ia] IIIC T135 °C Db CE markings ATEX (Directive 94/9/EC) Electromagnetic Compatibility (Directive 2004/108/EC) Low Voltage (Directive 2006/95/EC) *) All e-Box versions are only ATEX / IECEx approved. **) Pending
  • 4. ORDER INFORMATION DRÄGER POLYTRON 8000 Aluminium ‘d’ SS316L ‘d’ Aluminium ‘e’ SS316L ‘e’ Without relays 45 44 403 45 44 412 45 44 421 *) 45 44 430 *) With relays 45 44 404 45 44 413 45 44 422 **) 45 44 431 **) *) Order e-Box 68 12 420 for power only wires separately. **) Order e-Box 68 12 275 for power and/or relay wires separately. Magnetic wand for menu access (blue body, white logo) 45 44 101 e-Box Power only version (includes 1 cable gland) / Docking Station 68 12 420 e-Box Power, Relay and/or Remote version 68 12 275 (includes 2 cable glands) / Docking Station Cable Gland e-Box 68 12 868 Sensor Test Dongle 83 17 619 Diagnostic Dongle 83 17 860 Data Dongle 83 17 618 Combined Dongle (Data and Sensor Test Dongle) 83 23 218 Combined Dongle (Data and Diagnostic Dongle) 83 23 219 Pipe Mount Kit 45 44 198 Duct Mount Kit 68 12 725 Duct Mount Adapter for Remote EC Sensing Head 83 17 617 EC Sensing Head Remote w/ mount kit 68 12 684 MEC Sensor Adapter Polytron 5000/8000 68 12 695 IR Connection Kit Polytron 5000/8000 45 44 197 PolySoft 8000 83 23 405 PolySoft 8000 premium 83 23 411 Connection cable w/ plug for Remote EC Sensing Head 16 ft / 5 m 83 23 305 49 ft / 15 m 83 23 315 98 ft / 30 m 83 23 330 DrägerSensors Acidic Compounds AC 68 10 595 H2O2 HC 68 09 675 PH3/AsH3 68 09 695 NO2 68 09 655 Cl2 68 09 665 H2O2 LC 68 09 705 Hydride 68 09 635 O2 68 09 720 CO 68 09 605 H2S 68 10 435 Hydride SC 68 09 980 O2 LS 68 09 630 CO LS 68 09 620 H2S HC 68 09 710 N2H4 68 10 180 O3 68 10 290 CO LH 68 12 570 H2S LC 68 09 610 NH3 HC 68 09 645 OV1 68 10 740 COCl2 68 09 930 HCl 68 09 640 NH3 LC 68 09 680 OV2 68 10 745 H2 68 09 685 HCN 68 09 650 NO LC 68 09 625 SO2 68 09 660 Accessories Splash guard 68 12 510 Calibration Adapter PE, Europe 68 06 978 PE 45 09 314 Calibration Adapter Viton 68 10 536 DRÄGER POLYTRON 8000 – STATIONARY GAS DETECTOR (EC) 04 | 90 41 533 | 09.12-1 | Marketing Communications | PP | PR | LE | Printed in Germany | Chlorine-free – environmentally compatible | Subject to modifications | © 2012 Drägerwerk AG & Co. KGaA Tel: +44 (0)191 490 1547 Fax: +44 (0)191 477 5371 Email: northernsales@thorneandderrick.co.uk Website: www.heattracing.co.uk www.thorneanderrick.co.uk