Schneider MiCOM P541 line differential numerical relays are built for high-performance overhead line & cable applications. This device interfaces readily with the longitudinal (end-to-end) communications channels and also has optional distance backup protection. The MiCOM P54x relay family provides users with reliable high-speed current differential unit protection.
Value Proposition canvas- Customer needs and pains
Untitled presentation (31).pptx
1.
2. Functions Of Schneider Micom P541 Line
Differential Protection Numerical Relay
● Schneider MiCOM P541 line differential numerical relays are built
for high-performance overhead line & cable applications.
● This device interfaces readily with the longitudinal (end-to-end)
communications channels and also has optional distance backup
protection.
● The MiCOM P54x relay family provides users with reliable high-
speed current differential unit protection.
www.dsgenterprisesltd.com 91-7021624024
marketing@dsgenterprises.in
3. Functions Of Schneider Micom P541 Line
Differential Protection Numerical Relay
● The interface options support direct fibre optic as well as multiplexed
digital links.
● Models available in these series are MiCOM P541, P542, P543, P544,
P545 & P546
● Optimum selectivity is assured, as the scheme measures the currents
entering & leaving the protected plant item.
● Instantaneous tripping results in an internal fault, with stability for out-of-
zone faults.
www.dsgenterprisesltd.com 91-7021624024
marketing@dsgenterprises.in
4. Functions Of Schneider Micom P541 Line
Differential Protection Numerical Relay
● Tripping employs a proven characteristic of comparing differential current with through current for ease of testing.
● Phase differential elements of this type offer consistent detection of solid & resistive faults with optimum faulted phase
selection, tripping & indication.
● A full range of backup protection to enhance the dependability of the protection as hot-standby elements (distance
zones & overcurrent) can be easily brought into service whenever a signalling channel outage may occur.
www.dsgenterprisesltd.com 91-7021624024
marketing@dsgenterprises.in
5. Functions Of Schneider Micom P541 Line
Differential Protection Numerical Relay
● P543 & P546 devices deliver resident subcycle distance protection and
complement the powerful suite of primary & backup protection.
● A full scheme, five zone distance protections can be derived from the class-
leading MiCOM P443.
● Today The P54x series has become a standard in all HV, EHV & UHV line
protection applications, duplicated especially when dual redundant main
protection is demanded.
www.dsgenterprisesltd.com 91-7021624024
marketing@dsgenterprises.in
6. We have all types of equipment to protect and enhance your electric power system. Grab the portfolio to explore all
Schneider Numerical Relays which will help in improving your business. We Digital & Smart Grid Enterprises are the
leading Schneider Micom P546 Line Differential Protection Numerical Relay suppliers and exporters in Maharashtra.
We also deliver a wide range of services & customized solutions for Industries & Panel Builders. Contact us at
+917021624024 or mail us at marketing@dsgenterprises.in. We also deal in a wide range of products in Schneider.
Please click here if you would like to know more about Schneider Numerical Relays.
www.dsgenterprisesltd.com 91-7021624024
marketing@dsgenterprises.in