More Related Content Similar to Simplificação do Acesso à Ressonância Magnética e Redução de Disparidades na Saúde Brasileira (20) Simplificação do Acesso à Ressonância Magnética e Redução de Disparidades na Saúde Brasileira1. 1
Unrestricted © Siemens Healthineers, 2021
MAGNETOM Free.Star
MR para Todos.
Magnetic Resonance
Magnetic Resonance
Unrestricted © Siemens Healthineers, 2021
Daniela Barretto
Gerente de Desenvolvimento MR
América Latina
2. 2
Unrestricted © Siemens Healthineers, 2021
Unrestricted © Siemens Healthineers, 2021
2
Magnetic Resonance 2
MRI para Todos.
Nós acreditamos que todos merecem acesso a MRI.
3. 3
Unrestricted © Siemens Healthineers, 2022
Hoje é esta a realidade que temos no mundo…
milhões
De pessoas morrem de câncer a cada ano
10
pessoas
Sofrem com desordens neurológicas
1 em 4
bilhões
De pessoas possuem alguma condição
ortopédica
1.7
Já se provou desempenhar um papel fundamental no diagnóstico e tratamento das
doenças mais prevalentes do nosso mundo
MRI
Magnetic Resonance 3
Unrestricted © Siemens Healthineers, 2022
4. 4
Unrestricted © Siemens Healthineers, 2022
50 % das pessoas não possuem um
acesso adequado a MR
Mas infelizmente , o acesso a MR ainda é um desafio…
Magnetic Resonance
5. 5
Unrestricted © Siemens Healthineers, 2022
E para aqueles que tem acesso, muitas vezes enfrentam longas
filas de espera , além de enfrentarem longas viagens para
poder realizar um exame…
Magnetic Resonance
180 dias
Tempo de espera para
realizar
um exame no Brasil
SUS
7. Vertraulich © Siemens Healthineers, 2021
Magnetic Resonance
Infraestrututa e
suporte a toa
operação
Uma nova abordagem em
8. 8
Unrestricted © Siemens Healthineers, 2021
Unrestricted © Siemens Healthineers, 2021
8
Tecnologia DryCool
Liberdade além do hélio
hélio líquido
Magnetic Resonance 8
Benchmark em
operação Tempo para retorno de operação
Depois de um ramp down controlado:
< 4 horas
Ramp down time: < 30 min
Ramp up time depois de um
quench emergencial
: < 24 hours
9. Vertraulich © Siemens Healthineers, 2021
Light
< 3.2 t1
Small
24 m²
Our most compact MRI
MAGNETOM Free.Max
1
Measured in metric tons. Including all components within the scanner room.
Magnetic Resonance
Low
< 2 m
10. Vertraulich © Siemens Healthineers, 2021
MAGNETOM Free.Star Relocatable Suite
Uma “suite” de RM totalmente equipada pronta para
utilização
The information shown herein refers to products of 3rd party manufacturer’s and thus are in their regulatory responsibility. Please contact the 3rd party manufacturer for further information.
Magnetic Resonance
Controle do equipamento
e vestiáriao separados
Ambiente espaçoso
11. Vertraulich © Siemens Healthineers, 2021
Custo ao longo
dos anos
Redefinimos os impeditiditos de se ter uma Ressonância
Magnética
com o MAGNETOM Free.Star
Magnetic Resonance
High-value MRI enabled by digital innovations
myExam Companion
Innovative and intelligent service offering
Installation
Product
Operations
Service
Our most compact MRI & DryCool technology
12. Vertraulich © Siemens Healthineers, 2021
12
Unrestricted © Siemens Healthineers, 2023
Magnetic Resonance
Contour coils
Designed for comfort
14. Vertraulich © Siemens Healthineers, 2021
7 body regions
with flexible Contour Coils
5 body regions
with rigid / dedicated coils
BioMatrix Select&GO
Automatizado, preciso, e fácil posicionamento. Toda vez.
1
Data on file
Magnetic Resonance
30 % mais rápido1
E sempre reproduzível
AI BodyModel feito para facilitar a operação
Head
C-Spine
T-Spine
L-Spine
Shoulder
Thorax
Liver
Knee
Hip
Foot/Ankle
Pelvis
Powered by
Artificial Intelligence
15. Vertraulich © Siemens Healthineers, 2021
myExam Companion
Resultados consistentes. EvToda vez.
Magnetic Resonance
myExam Autopilot myExam Assist myExam Cockpit
NEW
Intelligently automated Flexibly guided Intuitively customized
Feito para dar assisteência, e desenhado para qualquer nível de conhecimento.
Powered by
Artificial Intelligence
16. 16
Unrestricted © Siemens Healthineers, 2022
Unrestricted © Siemens Healthineers, 2022
16
Transformando a MRI através da digitalização…
Magnetic Resonance
… Nos permitindo fazer mais com menos
Poder computacional
aumentado
drasticamente
Reconstrução de imagem
baseada em IA
Técnicas de aquisição
cada vez
mais eficientes
Simultaneous Multi-Slice
Compressed Sensing
CAIPIRINHA
E mais
Deep Resolve – O novo
paradigma
em performance clínica
17. 17
Unrestricted © Siemens Healthineers, 2022
Unrestricted © Siemens Healthineers, 2022
17
Poder da
digitalização
Inovação no processamento das imagens
Magnetic Resonance
0.55T
Benefícios clínicos inerentes
Unrestricted © Siemens Healthineers, 2022
17
High-V MRI
19. Vertraulich © Siemens Healthineers, 2021
Unrestricted © Siemens Healthineers, 2022
19
High-V MRI: uncovering root cause of paralysis
the difference made by effective diagnostics
Magnetic Resonance
Images courtesy of Dr. Elmar Merkle, University Hospital Basel | Case ID: 2aaaa2460
Reference X-Ray 3T image 1.5T image High-V image
20. Vertraulich © Siemens Healthineers, 2021
Unrestricted © Siemens Healthineers, 2022
20
High-V MRI
Strongly improves image quality for patients with implants
Magnetic Resonance
Study ID: 1aaaa3752 (left) and 4aaaa0508 (right)
Conventional MRI High-V MRI
21. Vertraulich © Siemens Healthineers, 2021
Unrestricted © Siemens Healthineers, 2022
21
High-V MRI
A paradigm shift for pulmonary MRI
Magnetic Resonance
Images courtesy of University Hospital Erlangen | Study ID: 5aaaa0007 & 4aaaa0418
High-V MRI
Post Covid-19 patient
Computed Tomography
Post Covid-19 patient
22. Vertraulich © Siemens Healthineers, 2021
Unrestricted © Siemens Healthineers, 2022
22
Reliable visualization of details in the small
Magnetic Resonance
PD TSE Fat Sat PD TSE
PAT 4 | Deep Resolve1
0.2 x 0.2 x 3.0 mm³
TA 2:08 min
PAT 4 | Deep Resolve1
0.3 x 0.3 x 3.0 mm³
TA 2:05 min
PAT 4 | Deep Resolve1
0.2 x 0.2 x 3.0 mm³
TA 2:07 min
T2 TSE
PAT 4 | Deep Resolve1
0.3 x 0.3 x 3.0 mm³
TA 1:44 min
T1 TSE
Total exam: 8:04 min
Powered by
Artificial Intelligence
23. Vertraulich © Siemens Healthineers, 2021
Unrestricted © Siemens Healthineers, 2022
23
Fast and detailed examination of elbow
Magnetic Resonance
PD TSE Fat Sat
PAT 4 | Deep Resolve1
0.2 x 0.2 x 3.0 mm³
TA 2:42 min
PAT 4 | Deep Resolve1
0.3 x 0.3 x 3.0 mm³
TA 2:21 min
PAT 4 | Deep Resolve1
0.3 x 0.3 x 3.0 mm³
TA 2:21 min
T2 TSE
PAT 4 | Deep Resolve1
0.3 x 0.3 x 3.0 mm³
TA 1:44 min
T1 SE
Total exam: 9:08 min
Powered by
Artificial Intelligence
24. Vertraulich © Siemens Healthineers, 2021
Unrestricted © Siemens Healthineers, 2022
24
Fast cartilage examination of obese knee
Magnetic Resonance
PD TSE Fat Sat T1 TSE
Total exam: 7:29 min
PAT 4 | Deep Resolve1
0.3 x 0.3 x 3.0 mm³
TA 1:55 min
PAT 4 | Deep Resolve1
0.3 x 0.3 x 3.0 mm³
TA 1:55 min
PAT 2 I SMS 2 | Deep Resolve1
0.3 x 0.3 x 3.0 mm³
TA 1:44 min
PAT 4 | Deep Resolve1
0.3 x 0.3 x 3.0 mm³
TA 1:55 min
25. Vertraulich © Siemens Healthineers, 2021
Vertraulich © Siemens Healthineers, 2020
25
Deep Resolve
T2 TSE T2 TSE Dark-Fluid
Deep Resolve
0.4 x 0.4 x 5.0 mm³
TA 1:03 min
Deep Resolve
0.5 x 0.5 x 5.0 mm³
TA 3:12 min
Magnetic Resonance
Standard
0.5 x 0.5 x 5.0 mm³
TA 4:00 min
Standard
0.4 x 0.4 x 5.0 mm³
TA 2:50 min
Powered by
Artificial Intelligence
26. Vertraulich © Siemens Healthineers, 2021
Vertraulich © Siemens Healthineers, 2020
26
Fast and comprehensive Neuro examination
T1 SE EPI SWI
DWI b1000
T2 TSE T2 TSE Dark-Fluid Time of flight
Deep Resolve1
0.6 x 0.5 x 5.0 mm³
TA 2:46 min
Deep Resolve1
0.4 x 0.3 x 5.0 mm³
TA 1:03 min
Deep Resolve1
0.5 x 0.5 x 5.0 mm³
TA 3:12 min
PAT 2
0.7 x 0.7 x 5.0 mm³
TA 2:26 min
0.8 x 0.7 x 2.0 mm³
TA 4:04 min
0.5 x 0.2 x 0.5 mm³
TA 5:31 min
Magnetic Resonance
Total exam: 19:02 min
Powered by
Artificial Intelligence
27. Vertraulich © Siemens Healthineers, 2021
Unrestricted © Siemens Healthineers, 2022
27
Alta resolução – exame de próstata
T2 TSE
PAT 4 | Deep Resolve
0.5 x 0.5 x 3.0 mm³
TA 3:55 min
PAT 4 | Deep Resolve
0.4 x 0.4 x 3.0 mm³
TA 4:15 min
PAT 4 | Deep Resolve
0.5 x 0.5 x 3.0 mm³
TA 3:52 min
Diffusion
b800
2.0 x 2.0 x 3.0 mm³
TA 6:19 min
Total exam: 18:21 min
Powered by
Artificial Intelligence
28. Vertraulich © Siemens Healthineers, 2021
Unrestricted © Siemens Healthineers, 2022
Coluna Lombar
Magnetic Resonance
T2 TSE T2 TSE STIR
T1 TSE
PAT 3 | Deep Resolve
0.4 x 0.4 x 4.0 mm³
TA 1:12 min
PAT 3 | Deep Resolve
0.4 x 0.4 x 4.0 mm³
TA 1:33 min
PAT 3 | Deep Resolve
0.4 x 0.4 x 4.0 mm³
TA 1:47 min 03 series 4:32 min
28
Powered by
Artificial Intelligence
29. Vertraulich © Siemens Healthineers, 2021
Unrestricted © Siemens Healthineers, 2022
29
Deep Resolve1
Faster than ever before with even better image quality
1
Deep Resolve Boost is currently under development and not commercially available with MAGNETOM Free.Max. Its future availability cannot be guaranteed.
Study ID: 7aaaa0371
T2 TSE
Standard
0.4 x 0.4 x 5.0 mm³
TA 2:50 min
Deep Resolve
0.4 x 0.4 x 5.0 mm³
TA 2:06 min
Magnetic Resonance
Powered by
Artificial Intelligence
28%
faster
30. Vertraulich © Siemens Healthineers, 2021
Vertraulich © Siemens Healthineers, 2020
30
Magnetic Resonance
Nós acreditamos que todos merecem acesso a MRI.