SlideShare a Scribd company logo
1 of 32
Download to read offline
STEP-BY-STEP INSTRUCTIONS ON THE
PROSTHETIC PROCEDURES
Straumann®
Anatomic IPS e.max®
Abutment
15X.811.indd 1 09.10.12 11:40
The ITI (International Team for Implantology) is academic partner of Institut Straumann
in the areas of research and education.
15X.811.indd 2 09.10.12 11:40
CONTENT
Straumann®
Anatomic IPS e.max®1
Abutment 2
1. Cement-retained crowns and bridges 3
1.1 Straumann®
Anatomic IPS e.max®1
Abutment – Lab procedure 3
1.2 Straumann®
Anatomic IPS e.max®1
Abutment – Prosthetic procedure 7
1.3 Straumann®
Anatomic IPS e.max®1
Abutment – Chairside procedure for
temporary restorations 8
2. Screw-retained crowns, directly veneered 12
2.1 Straumann®
Anatomic IPS e.max®1
Abutment – Lab procedure 12
2.2 Straumann®
Anatomic IPS e.max®1
Abutment – Prosthetic procedure 17
3. Screw-retained crowns using the press-on technique 18
3.1 Straumann®
Anatomic IPS e.max®1
Abutment – Lab procedure 18
3.2 Straumann®
Anatomic IPS e.max®1
Abutment – Prosthetic procedure 26
Important guidelines 27
15X.811.indd 1 09.10.12 11:40
2
STRAUMANN®
ANATOMIC IPS e.max®1
ABUTMENT
Intended use
p Cement-retained crowns and bridges via mesostructure
– Conventional procedure
– Temporary restoration chairside
p Screw-retained crowns
– Direct veneering (with IPS e.max®
Ceram1
)
– Press-on technique (with IPS e.max®
ZirPress1
)
Material
p Zirconium dioxide
Characteristics
Simple
p Processing of a highly esthetic ceramic abutment in different
colors with conventional lab methods
p Less grinding necessary due to prepared mucosa margins
p Adaptation to natural soft tissue contour due to prepared
mucosa margins in different heights
p Oval shape resembles emergence profile of a natural tooth
Reliable
p Biocompatible and low thermal conductivity
p High-performance all-ceramics thanks to a high strength
and high fracture toughness
p Reduced risk of margins shining through the soft tissue even
with thin mucosa biotype
p CrossFit®
Connection
p Precise fit
Note
Only use an original Straumann®
basal screw for ceramic
abutment for the final insertion of the Straumann®
Anatomic
IPS e.max®1
Abutment. The Straumann®
Anatomic IPS e.max®1
Abutment is available in the following shades: MO 0 and
MO 1 (MO = Medium Opacity). Recommendations regard-
ing the sterilization procedure can be found in the instructions
for use.
Straumann®
Anatomic IPS e.max®
Abutment
15X.811.indd 2 09.10.12 11:40
1c
1a
1b
3
1.1 Straumann®
Anatomic IPS e.max®1
Abutment – Lab procedure
The following case describes the fabrication of a cement-retained crown by using the Straumann®
Anatomic IPS e.max®1
Abutment.
Step 1 – Fabricating the master cast and wax-up
p Fabricate the master cast including a gingival mask with the
corresponding implant analog (see instructions in chapter 5
in brochure Art. No. 152.810).
p For optimal esthetic planning, design a full anatomical wax-up.
p Make a silicone key over the full wax-up in order to define
the optimal shape of the modified abutment.
1. CEMENT-RETAINED CROWNS AND BRIDGES
1. Cement-retained crowns and bridges
Cement-retained restorations need to fulfill the following criteria (see 2c):
p Individualized abutments must have cusp and marginal ridge support.
p The maximum thickness of the veneering material on top of the coping must not exceed a maximum
of 2.0 mm in all directions.
p Avoid any sharp edges.
15X.811.indd 3 09.10.12 11:40
2c
2a
2b
NC NC
RC RC
2 mm
16 mm 16 mm
2 mm
2 mm
16 mm 16 mm
2 mm
NC GH 2 mm
RC GH 2 mm
4
Step 2 – Preparing the Straumann®
Anatomic
IPS e.max®1
Abutment
p Place the abutment on the polishing aid/analog and hand
tighten the screw using the SCS screwdriver.
p For the individualization of the Straumann®
Anatomic IPS
e.max®1
Abutment, it is recommended to work with a
water-cooled turbine and abrasive instruments that are ap-
propriate for grinding sintered ZrO2
material. Work with a
low grinding pressure and avoid any spark formation. The
Ivoclar Vivadent grinding instrument recommendations for
IPS e.max®1
must be followed.
Note
In order to keep sufficient stability of the abutment, do not
deviate from the dimensions shown in the following graphics
(2c). The height of the abutment must achieve at least 65 % of
the complete restoration.
p The final geometry of the abutment has to meet the require-
ments of the material of the final restoration for cement-
retained crowns and bridges.
1. Cement-retained crowns and bridges
Cemented
0.3 mm
1.3 mm
min. 4 mm
0.5 mm
3.5 mm
min. 4 mm
0.75 mm
0.5 mm
1.3 mm
min. 4 mm
0.75 mm
0.5 mm
3.5 mm
min. 4 mm
NC GH 3.5 mm
RC GH 3.5 mm
15X.811.indd 4 09.10.12 11:40
3a
2d
3b
5
Step 3 – Fabricating the superstructure
p Use a standard procedure to fabricate the ceramic coping
with the Straumann®
CARES®
Scan CS2 scanner and the
Straumann®
CARES®
Visual software.
p Following the Ivoclar Vivadent grinding instrument rec-
ommendations for IPS e.max®1
a regeneration firing for
cement-retained crowns and bridges is not required. The
regeneration firing has to be conducted if the Ivoclar Vivadent
grinding instrument recommendations for IPS e.max®1
are
not followed or if a further thermal processing is necessary.
The regeneration firing parameter are: 65 °C (117 °F) per
minute heating up to 1050 °C (1922 °F) / 15 minute hold-
ing time and long-term cooling down with 25 °C (45 °F)
per minute to 750 °C (1382 °F).
1. Cement-retained crowns and bridges
p Veneer the coping with conventional veneering material
synchronized to the thermal expansion coefficient of the
ceramic coping.
p Coefficient of thermal expansion2
(CTE) (100–500 °C)
10.80±0.25 10-6
K-1
p For veneering follow the recommendations of the ceramic
material manufacturer.
15X.811.indd 5 09.10.12 11:40
3c
3d
6
Note
In case of adhesive bonding, sandblast the portions of the
abutment surface which will be covered with cement with
Al2
O3
(type 100 microns) at 0.5–1.0 bar (15–30 psi). While
sandblasting, the implant configuration must be protected with
the polishing aid.
1. Cement-retained crowns and bridges
15X.811.indd 6 09.10.12 11:41
2a
2b
7
Step 1 – Preparation
p Remove the healing cap or temporary restoration.
p Remove the superstructure from the master cast and unscrew
the abutment from the analog.
p Clean and dry the interior of the implant and the abutment
thoroughly.
p Prepare the surface of the abutment corresponding to the
cementation material which will be used (e.g. in case of
adhesive bonding apply primer).
p Condition the inner surface of the superstructure according to
the instructions for use given by the according manufacturer
(e.g. in case of adhesive bonding apply primer).
1.2 Straumann®
Anatomic IPS e.max®1
Abutment – Prosthetic procedure
The final restoration is delivered to the doctor’s office on the master cast.
Step 2 – Final insertion
p Position the cleaned abutment in the implant. Tighten the
screw to 35 Ncm using the SCS screwdriver along with
the ratchet and the torque control device (see instructions in
chapter 7.5 in brochure Art. No. 152.810).
p Close the SCS screw channel with cotton and sealing
compound (i.e. gutta-percha). This allows for later re-
moval of the modified abutment in the event a restoration
replacement is required.
p Cement the superstructure onto the abutment.
p Remove any excess cement.
Note
Only use an original Straumann®
basal screw for ceramic
abutment for the final insertion of the Straumann®
Anatomic
IPS e.max®1
Abutment.
1. Cement-retained crowns and bridges
15X.811.indd 7 09.10.12 11:41
1b
1a
NC NC
RC RC
2 mm
16 mm 16 mm
2 mm
16 mm 16 mm
2 mm
NC GH 2 mm
RC GH 2 mm
2 mm
88
1.3 Straumann®
Anatomic IPS e.max®1
Abutment – Chairside procedure for temporary restorations
The following case describes the usage of the Straumann®
Anatomic IPS e.max®1
Abutment chairside.
Step 1 – Preparing the Straumann®
Anatomic
IPS e.max®1
Abutment
p For the individualization of the Straumann®
Anatomic IPS
e.max®1
Abutment, it is recommended to work with a water-
cooled turbine and abrasive instruments that are appropri-
ate for grinding sintered ZrO2
material. Work with a low
grinding pressure and avoid any spark formation. The Ivo-
clar Vivadent grinding instrument recommendations for IPS
e.max®1
must be followed.
Note
In order to keep sufficient stability of the abutment, do not
deviate from the dimensions shown in the following graphics
(1b). The height of the abutment must achieve at least 65 % of
the complete restoration.
p The final geometry of the abutment has to meet the require-
ments of the material of the final restoration for cement-
retained crowns and bridges.
1. Cement-retained crowns and bridges
Cemented
0.3 mm
1.3 mm
min. 4 mm
0.5 mm
3.5 mm
min. 4 mm
0.75 mm
0.5 mm
1.3 mm
min. 4 mm
0.75 mm
0.5 mm
3.5 mm
min. 4 mm
NC GH 3.5 mm
RC GH 3.5 mm
15X.811.indd 8 09.10.12 11:41
1c
2b
2a
99
p Following the Ivoclar Vivadent grinding instrument rec-
ommendations for IPS e.max®1
a regeneration firing for
cement-retained crowns and bridges is not required. The
regeneration firing has to be conducted if the Ivoclar Viva-
dent grinding instrument recommendations for IPS e.max®1
are not followed or if a further thermal processing is neces-
sary. The regeneration firing parameter are: 65 °C (117 °F)
per minute heating up to 1050 °C (1922 °F) / 15 minute
holding time and long-term cooling down with 25 °C (45 °F)
per minute to 750 °C (1382 °F).
1. Cement-retained crowns and bridges
Step 2 – Placing the modified Straumann®
Anatomic
IPS e.max®1
Abutment
p Place the abutment on the implant and tighten the screw
with a torque between 15 Ncm and 35 Ncm using the
SCS screwdriver along with the ratchet and the torque
control device (see instructions in chapter 7.5 in brochure
Art. No. 152.810).
Note
Before taking the abutment level impression the abutment needs
to be torqued with 35 Ncm.
p Cover the screw head with absorbent cotton or gutta-percha
and seal the screw channel temporarily (e.g. with absorbent
cotton).
15X.811.indd 9 09.10.12 11:41
2c
4
3
10
p Take an impression with an individualized impression tray
and order the final restoration.
1. Cement-retained crowns and bridges
Step 3 – Fabricating the cement-retained temporary
single crown
Use a standard procedure to fabricate the cement-retained
single crown (e.g. grind out a prefabricated plastic tooth).
Step 4 – Cementing the temporary single crown
p Coat the internal configuration of the crown with temporary
cement and cement it onto the Straumann®
Anatomic IPS
e.max®1
Abutment.
p Remove any excess cement.
15X.811.indd 10 09.10.12 11:42
5a
5b
111. Cement-retained crowns and bridges
Step 5 – Insertion of the final restoration
p Remove the temporary restoration.
p Clean and dry the interior of the abutment thoroughly.
p Close the SCS screw channel with cotton and sealing com-
pound (i.e. gutta-percha). This allows for later removal of the
modified abutment in the event a restoration replacement
is required.
p Cement the superstructure onto the abutment.
p Remove any excess cement.
15X.811.indd 11 09.10.12 11:42
1c
1b
1a
12 2. Screw-retained crowns, directly veneered
2.1 Straumann®
Anatomic IPS e.max®1
Abutment – Lab procedure
The following case describes the fabrication of screw-retained crowns directly veneered, when using the Straumann®
Anatomic IPS e.max®1
Abutment and IPS e.max®
Ceram1
.
Step 1 – Fabricating the master cast and wax-up
p Fabricate the master cast including a gingival mask with the
corresponding implant analog (see instructions in chapter 5
in brochure Art. No. 152.810).
p For optimal esthetic planning, design a full anatomical
wax-up.
p Make a silicone key over the full wax-up in order to define
the optimal shape of the modified abutment.
2. SCREW-RETAINED CROWNS, DIRECTLY VENEERED
Screw-retained restorations need to fulfill the following criteria (see 2c):
p In the anterior region, screw hole access must be located in the palatal/lingual area of the restoration.
p The screw hole position in the incisal or labial area is contraindicated.
p In the posterior area, screw hole position must be located in the center of the occlusal area of the restoration.
p Before veneering or press-on procedure the individualized abutment must have a reduced anatomically supporting design
(cusp and marginal support).
p The maximum thickness of the veneering material on top of the individualized abutments (layering ceramic and/or press-on
ceramic) must not exceed a maximum of 2.0 mm in all directions of the screw retained restoration.
15X.811.indd 12 09.10.12 11:43
2a
2b
132. Screw-retained crowns, directly veneered
Step 2 – Preparing the Straumann®
Anatomic
IPS e.max®1
Abutment
p Place the abutment on the polishing aid/analog and hand
tighten the screw using the SCS screwdriver.
p For the individualization of the Straumann®
Anatomic
IPS e.max®1
Abutment, it is recommended to work with a
water-cooled turbine and abrasive instruments that are ap-
propriate for grinding sintered ZrO2
material. Work with a
low grinding pressure and avoid any spark formation. The
Ivoclar Vivadent grinding instrument recommendations for
IPS e.max®1
must be followed.
15X.811.indd 13 09.10.12 11:43
2c
2d
NC NC
RC RC
2 mm
16 mm 16 mm
2 mm
2 mm
16 mm 16 mm
2 mm
NC GH 2 mm
RC GH 2 mm
14
Note
In order to keep sufficient stability of the abutment, do not
deviate from the dimensions shown in the following graphics
(2c). The height of the abutment must achieve at least 65 % of
the complete restoration.
p The final geometry of the abutment has to meet the require-
ments of the veneering material.
2. Screw-retained crowns, directly veneered
p After grinding and/or polishing the abutment a regenera-
tion firing has to be conducted in a firing furnace: 65 °C
(117 °F) per minute heating up to 1050 °C (1922 °F) /
15 minutes holding time and long-term cooling down with
25 °C (45 °F) per minute to 750 °C (1382 °F).
Directly veneered
max.
2 mm
max.
2 mm
max.
2 mm
max.
2 mm
max.
2 mm
max.
2 mm
max.
2 mm
0.3 mm
1.3 mm
min. 4 mm
0.5 mm
3.5 mm
min. 4 mm
0.75 mm
0.5 mm
1.3 mm
min. 4 mm
0.75 mm
0.5 mm
3.5 mm
min. 4 mm
NC GH 3.5 mm
RC GH 3.5 mm
15X.811.indd 14 09.10.12 11:43
3a
3b
3c
152. Screw-retained crowns, directly veneered
Step 3 – Veneering
p For the veneering of the Straumann®
Anatomic IPS e.max®1
Abutment, use conventional veneering material synchronized
to the thermal expansion coefficient of the abutment.
p Coefficient of thermal expansion2
(CTE) (100–500 °C)
10.80±0.25 10-6
K-1
p In this case IPS e.max®
Ceram1
has been used. For fur-
ther details please consult the brochure “Instructions for use
IPS e.max®
Ceram1
” (www.ivoclarvivadent.com).
p Steam clean the abutment and apply the IPS e.max®
Ceram
ZirLiner1
only where IPS e.max®
Ceram1
will be applied
later on.
p The implant configuration must be protected with the polish-
ing aid while applying the IPS e.max®
Ceram ZirLiner1
.
Note
Do not sandblast the abutment before applying the IPS e.max®
Ceram Liner1
. Avoid any application of IPS e.max®
Ceram
ZirLiner1
into the screw channel.
Note
Do not apply IPS e.max®
Ceram ZirLiner1
on the inner con-
figuration. In case of an adaptation of the emergence profile
it is recommended to place the abutment upside down on the
firing tray to prevent the ZirLiner1
from flowing towards the inner
configuration during firing.
15X.811.indd 15 09.10.12 11:43
3f
3e
3d
16 2. Screw-retained crowns, directly veneered
p Particular attention must be given to an even layer thickness
of the porcelain veneered on the abutment.
Note
Observe the maximum thickness of the layering ceramic
material (max. 2 mm).
p Final restoration
15X.811.indd 16 09.10.12 11:44
2a
2b
172. Screw-retained crowns, directly veneered
2.2 Straumann®
Anatomic IPS e.max®1
Abutment – Prosthetic procedure
The final restoration is delivered to the doctor’s office on the master cast.
Step 1 – Preparation
p Remove the healing cap or temporary restoration.
p Remove the veneered abutment from the master cast.
p Clean and dry the interior of the implant and the abutment
thoroughly.
Step 2 – Final insertion
p Position the cleaned and veneered abutment in the implant.
Tighten the screw to 35 Ncm using the SCS screwdriver
along with the ratchet and the torque control device (see
instruction in chapter 7.5, in brochure Art. No. 152.810).
p Close the SCS screw channel with cotton and sealing com-
pound (i.e. gutta-percha, composite). This allows for later
removal of the modified abutment in the event a restoration
replacement is required.
Note
Only use an original Straumann®
basal screw for ceramic
abutment for the final insertion of the Straumann®
Anatomic
IPS e.max®1
Abutment.
15X.811.indd 17 09.10.12 11:44
1c
1b
1a
18 3. Screw-retained crowns using the press-on technique
3.1 Straumann®
Anatomic IPS e.max®1
Abutment – Lab procedure
The following case describes the fabrication of a screw-retained crown when using the Straumann®
Anatomic IPS e.max®1
Abutment in combination with the press-on technique. In this case IPS e.max®
ZirPress1
has been used.
Step 1 – Fabricating the master cast and wax-up
p Fabricate the master cast including a gingival mask with the
correspondingimplantanalog(seeinstructionsinchapter5in
brochure Art. No. 152.810).
p For optimal esthetic planning, design a full anatomical
wax-up.
p Make a silicone key over the full wax-up in order to define
the optimal shape of the modified abutment.
3. SCREW-RETAINED CROWNS USING THE PRESS-ON TECHNIQUE
Screw-retained restorations need to fulfill the following criteria (see 2c):
p In the anterior region, screw hole access must be located in the palatal/lingual area of the restoration.
p The screw hole position in the incisal or labial area is contraindicated.
p In the posterior area, screw hole position must be located in the center of the occlusal area of the restoration.
p Before veneering or press-on procedure the individualized abutment must have a reduced anatomically supporting design
(cusp and marginal support).
p The maximum thickness of the veneering material on top of the individualized abutments (layering ceramic and/or press-on
ceramic) must not exceed a maximum of 2.0 mm in all directions of the screw retained restoration.
15X.811.indd 18 09.10.12 11:44
2a
2b
193. Screw-retained crowns using the press-on technique
Step 2 – Preparing the Straumann®
Anatomic
IPS e.max®1
Abutment
p Place the abutment on the polishing aid/analog and hand
tighten the screw using the SCS screwdriver.
p For the individualization of the Straumann®
Anatomic
IPS e.max®1
Abutment, it is recommended to work with a
water-cooled turbine and abrasive instruments that are ap-
propriate for grinding sintered ZrO2
material. Work with a
low grinding pressure and avoid any spark formation. The
Ivoclar Vivadent grinding instrument recommendations for
IPS e.max®1
must be followed.
15X.811.indd 19 09.10.12 11:44
2c
2d
NC NC
RC RC
NC GH 2 mm
RC GH 2 mm
2 mm
16 mm
2 mm
16 mm 16 mm
2 mm
16 mm
2 mm
20 3. Screw-retained crowns using the press-on technique
Note
In order to keep sufficient stability of the abutment, do not
deviate from the dimensions shown in the following graphics
(2c). The height of the abutment must achieve at least 65 % of
the complete restoration.
p The final geometry of the abutment has to meet the require-
ments of the framework and veneering material.
p After grinding and/or polishing the abutment a regeneration
firing has to be conducted in a firing furnace: 65 °C (117 °F)
per minute heating up to 1050 °C (1922 °F)/15 minutes
holding time and long-term cooling down with 25 °C
(45 °F) per minute to 750 °C (1382 °F).
max.
2 mm
max.
2 mm
max.
2 mm
max.
2 mm
max.
2 mm
max.
2 mm
max.
2 mm
Directly veneered
0.3 mm
1.3 mm
min. 4 mm
0.5 mm
3.5 mm
min. 4 mm
0.75 mm
0.5 mm
1.3 mm
min. 4 mm
0.75 mm
0.5 mm
3.5 mm
min. 4 mm
NC GH 3.5 mm
RC GH 3.5 mm
15X.811.indd 20 09.10.12 11:44
3a
3b
3c
213. Screw-retained crowns using the press-on technique
Step 3 – Process of press-on technique
p For pressing onto the Straumann®
Anatomic IPS e.max®1
Abutment, use conventional press-on material synchronized
to the thermal expansion coefficient of the abutment.
p Coefficient of thermal expansion2
(CTE) (100–500 °C)
10.80±0.25 10-6
K-1
p In this case IPS e.max®
ZirPress1
has been used. For fur-
ther details please consult the brochure “Instructions for use
IPS e.max®
ZirPress1
” (www.ivoclarvivadent.com).
p Steam clean the abutment and apply the IPS e.max®
Ceram
ZirLiner1
only where IPS e.max®
ZirPress1
will be applied
later on.
p The implant configuration must be protected with the polish-
ing aid while applying the IPS e.max®
Ceram ZirLiner1
.
Note
Do not sandblast the abutment before applying the IPS e.max®
Ceram Liner1
. Avoid any application of IPS e.max®
Ceram
ZirLiner1
into the screw channel.
Note
Do not apply IPS e.max®
Ceram ZirLiner1
on the inner con-
figuration. In case of an adaptation of the emergence profile
it is recommended to place the abutment upside down on the
firing tray to prevent the ZirLiner1
from flowing towards the inner
configuration during firing.
15X.811.indd 21 09.10.12 11:45
3d
3f
3e
22 3. Screw-retained crowns using the press-on technique
Note
In order to prevent IPS e.max®
ZirPress1
to intrude into the screw
channel of the abutment do not cover the screw channel with
wax.
p Sprueing
p Observe the respective material thickness (minimum 0.7 mm
up to 2 mm) in order to ensure a proper press-on restora-
tion.
15X.811.indd 22 09.10.12 11:45
3h
3j
3i
3g
233. Screw-retained crowns using the press-on technique
p Cover the whole abutment with investment material and
ensure that the screw channel is also completely filled.
p Before pressing, ensure that the pressing furnace is suffi-
ciently preheated.
p The implant configuration must be protected with the
polishing aid (e. g. sandblasting).
15X.811.indd 23 09.10.12 11:46
3m
3l
3k
24 3. Screw-retained crowns using the press-on technique
Note
The long-term success of the prosthetic work depends on the
accurate fit of the restoration. Therefore the following recom-
mendations must be observed:
p Allow for enough cooling time of the press-on abutment
before divestment
p Rough divestment is carried out with glass polishing beads
at 4 bar (60 psi) pressure
p Fine divestment is carried out with glass polishing beads at
2 bar (30 psi) pressure
p Do not use Al2
O3
for rough or fine divestment
p Do not sandblast the conical portion of the abutment and
always protect the implant/abutment interface with the
polishing aid
p Immerse the pressed objects into the IPS e.max®
Press Invex
Liquid1
(min. 5 minutes, max. 10 minutes) and ensure that
they are completely covered.
p Carefully remove the white reaction layer on the pressed ob-
jects with Al2
O3
(type 100 microns) at 1–2 bar (15–30 psi)
pressure.
15X.811.indd 24 09.10.12 11:46
3n
3o
253. Screw-retained crowns using the press-on technique
p Veneer, shade and glaze the restoration according to the
individual situation.
Note
The implant configuration must be protected with the polishing
aid while applying the IPS e.max®
Ceram1
.
p Final restoration
15X.811.indd 25 09.10.12 11:46
2a
2b
26 3. Screw-retained crowns using the press-on technique
Step 1 – Preparation
p Remove the healing cap or temporary restoration.
p Remove the overpressed abutment from the master cast.
p Clean and dry the interior of the implant and the abutment
thoroughly.
Step 2 – Final insertion
p Position the cleaned abutment in the implant. Tighten the
screw to 35 Ncm using the SCS screwdriver along with
the ratchet and the torque control device (see instructions in
chapter 7.5 in brochure Art. No. 152.810).
p Close the SCS screw channel with cotton and sealing com-
pound (i.e. gutta-percha, composite). This allows a later
removal of the modified abutment in the event a restoration
replacement is required.
Note
Only use an original Straumann®
basal screw for ceramic
abutment for the final insertion of the Straumann®
Anatomic
IPS e.max®1
Abutment.
3.2 Straumann®
Anatomic IPS e.max®1
Abutment – Prosthetic procedure
The final restoration is delivered to the doctor’s office on the master cast.
15X.811.indd 26 09.10.12 11:47
27
Please note
Practitioners must have appropriate knowledge and instruction in the
handling of the Straumann CADCAM products or other Straumann
products (“Straumann Products”) for using the Straumann Products
safely and properly in accordance with the instructions for use.
The Straumann Product must be used in accordance with the
instructions for use provided by the manufacturer. It is the practitioner’s
responsibility to use the device in accordance with these instructions
for use and to determine, if the device fits to the individual patient
situation.
The Straumann Products are part of an overall concept and must be
used only in conjunction with the corresponding original components
and instruments distributed by Institut Straumann AG, its ultimate
parent company and all affiliates or subsidiaries of such parent
company (“Straumann”), except if stated otherwise in this document
or in the instructions for use for the respective Straumann Product.
If use of products made by third parties is not recommended by
Straumann in this document or in the respective instructions for use,
any such use will void any warranty or other obligation, express or
implied, of Straumann.
Availability
Some of the Straumann Products listed in this document may not be
available in all countries.
Caution
In addition to the caution notes in this document, our products must
be secured against aspiration when used intraorally.
Validity
Upon publication of this document, all previous versions are
superseded.
Documentation
For detailed instructions on the Straumann Products contact your
Straumann representative.
Copyright and trademarks
Straumann®
documents may not be reprinted or published, in whole
or in part, without the written authorization of Straumann.
Straumann®
and/or other trademarks and logos from Straumann®
mentioned herein are the trademarks or registered trademarks of
Straumann Holding AG and/or its affiliates.
Explanation of the symbols on labels and instruction leaflets
IMPORTANT GUIDELINES
Batch code
Catalogue number
Sterilized using irradiation
…min.
Lower limit of temperature
…max.
Upper limit of temperature
…max.
…min.
Temperature limitation
Caution: Federal law restricts this device
to sale by or on the order of a dental
professional.
Do not re-use
Non-sterile
Caution, consult accompanying documents
Use by
Keep away from sunlight
Straumann Products with the CE mark fulfill
the requirements of the Medical Devices
Directive 93/42 EEC
0123
Consult instructions for use
IMPORTANT GUIDELINES
15X.811.indd 27 09.10.12 11:47
28
Straumann®
Anatomic IPS e.max®1
Abutment is avaible in the following shades:
MO 0 and MO 1 (MO = Medium Opacity)
1
IPS e.max®
, IPS e.max®
Ceram, IPS e.max®
ZirPress, IPS e.max®
Ceram ZirLiner, IPS e.max®
Ceram Liner, IPS e.max®
Press Invex Liquid
are registered trademarks of Ivoclar Vivadent AG, Liechtenstein
2
Ivoclar Vivadent AG, Liechtenstein
15X.811.indd 28 09.10.12 11:47
15X.811.indd 3 09.10.12 11:47
International Headquarters
Institut Straumann AG
Peter Merian-Weg 12
CH-4002 Basel, Switzerland
Phone	+41 (0)61 965 11 11
Fax	 +41 (0)61 965 11 01
www.straumann.com
StraumannproductsareCEmarked    10/12  152.811/en    BG21012
© Institut Straumann AG, 2012. All rights reserved.
Straumann®
and/or other trademarks and logos from Straumann®
mentioned herein are the trademarks or registered trademarks of Straumann Holding AG
and/or its affiliates. All rights reserved.

More Related Content

Similar to ivoclar ips manual

Report about the repairation of the Raw mill Slide Ring and shell (Modificat...
Report about the repairation of the Raw mill Slide Ring and  shell (Modificat...Report about the repairation of the Raw mill Slide Ring and  shell (Modificat...
Report about the repairation of the Raw mill Slide Ring and shell (Modificat...Moaz Emad gaber
 
IRJET- Cost Effective Manufacturing and Optimization of the Formula Student N...
IRJET- Cost Effective Manufacturing and Optimization of the Formula Student N...IRJET- Cost Effective Manufacturing and Optimization of the Formula Student N...
IRJET- Cost Effective Manufacturing and Optimization of the Formula Student N...IRJET Journal
 
IRJET- Manufacturing of Mould Die for Nut Ring and Process Cycle Optimization
IRJET- Manufacturing of Mould Die for Nut Ring and Process Cycle OptimizationIRJET- Manufacturing of Mould Die for Nut Ring and Process Cycle Optimization
IRJET- Manufacturing of Mould Die for Nut Ring and Process Cycle OptimizationIRJET Journal
 
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-AThorne & Derrick International
 
98f5ce56 bca9-41ef-b8c9-095d7bf17a1c-151202050517-lva1-app6891
98f5ce56 bca9-41ef-b8c9-095d7bf17a1c-151202050517-lva1-app689198f5ce56 bca9-41ef-b8c9-095d7bf17a1c-151202050517-lva1-app6891
98f5ce56 bca9-41ef-b8c9-095d7bf17a1c-151202050517-lva1-app6891AkashPatel747
 
A model support plan for underground coal mines , under regulation 123 of the...
A model support plan for underground coal mines , under regulation 123 of the...A model support plan for underground coal mines , under regulation 123 of the...
A model support plan for underground coal mines , under regulation 123 of the...nasina balasubrahmayam
 
Pharma catalogue 2017 18
Pharma catalogue 2017 18Pharma catalogue 2017 18
Pharma catalogue 2017 18vijay oak
 
publication_1580218342.pdf
publication_1580218342.pdfpublication_1580218342.pdf
publication_1580218342.pdfPradeepPokhrel5
 
Consistency test,Initial & Final setting time of Hydraulic Cement specimen
Consistency test,Initial & Final setting time of Hydraulic Cement specimenConsistency test,Initial & Final setting time of Hydraulic Cement specimen
Consistency test,Initial & Final setting time of Hydraulic Cement specimenMUST,Mirpur AJK,Pakistan
 
PLAIN AND REINFORCED CONRETE (LAB MANUAL)
PLAIN AND REINFORCED CONRETE (LAB MANUAL)PLAIN AND REINFORCED CONRETE (LAB MANUAL)
PLAIN AND REINFORCED CONRETE (LAB MANUAL)Hamza Waheed
 
Experimental Study of Improvement in Confinement of Reinforced Concrete Column
Experimental Study of Improvement in Confinement of Reinforced Concrete ColumnExperimental Study of Improvement in Confinement of Reinforced Concrete Column
Experimental Study of Improvement in Confinement of Reinforced Concrete ColumnIRJET Journal
 
Instruction- 3 Core Polymeric (XLPE EPR) 6.6kV-7.2kV Heat Shrink Cable Termin...
Instruction- 3 Core Polymeric (XLPE EPR) 6.6kV-7.2kV Heat Shrink Cable Termin...Instruction- 3 Core Polymeric (XLPE EPR) 6.6kV-7.2kV Heat Shrink Cable Termin...
Instruction- 3 Core Polymeric (XLPE EPR) 6.6kV-7.2kV Heat Shrink Cable Termin...Thorne & Derrick International
 
Piezoelectric Diaphram Bulk Manufacturing_v7.5
Piezoelectric Diaphram Bulk Manufacturing_v7.5Piezoelectric Diaphram Bulk Manufacturing_v7.5
Piezoelectric Diaphram Bulk Manufacturing_v7.5Shahriar Shariat
 
Inspecting Correctly Slide Show
Inspecting Correctly Slide ShowInspecting Correctly Slide Show
Inspecting Correctly Slide ShowScott Workman
 
BEHAVIOR OF CONCRETE WITH PARTIAL REPLACEMENT OF C- AGGREGATES BY GRANULATED ...
BEHAVIOR OF CONCRETE WITH PARTIAL REPLACEMENT OF C- AGGREGATES BY GRANULATED ...BEHAVIOR OF CONCRETE WITH PARTIAL REPLACEMENT OF C- AGGREGATES BY GRANULATED ...
BEHAVIOR OF CONCRETE WITH PARTIAL REPLACEMENT OF C- AGGREGATES BY GRANULATED ...IRJET Journal
 
Ppt on test certificate-Amit Payal
Ppt on test certificate-Amit PayalPpt on test certificate-Amit Payal
Ppt on test certificate-Amit PayalAMIT PAYAL
 
Sla user guide
Sla user guideSla user guide
Sla user guideKei Lim
 

Similar to ivoclar ips manual (20)

Ips+e max+clinical+guide
Ips+e max+clinical+guideIps+e max+clinical+guide
Ips+e max+clinical+guide
 
Report about the repairation of the Raw mill Slide Ring and shell (Modificat...
Report about the repairation of the Raw mill Slide Ring and  shell (Modificat...Report about the repairation of the Raw mill Slide Ring and  shell (Modificat...
Report about the repairation of the Raw mill Slide Ring and shell (Modificat...
 
IRJET- Cost Effective Manufacturing and Optimization of the Formula Student N...
IRJET- Cost Effective Manufacturing and Optimization of the Formula Student N...IRJET- Cost Effective Manufacturing and Optimization of the Formula Student N...
IRJET- Cost Effective Manufacturing and Optimization of the Formula Student N...
 
Guniting ppt.pptx
Guniting ppt.pptxGuniting ppt.pptx
Guniting ppt.pptx
 
IRJET- Manufacturing of Mould Die for Nut Ring and Process Cycle Optimization
IRJET- Manufacturing of Mould Die for Nut Ring and Process Cycle OptimizationIRJET- Manufacturing of Mould Die for Nut Ring and Process Cycle Optimization
IRJET- Manufacturing of Mould Die for Nut Ring and Process Cycle Optimization
 
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
 
98f5ce56 bca9-41ef-b8c9-095d7bf17a1c-151202050517-lva1-app6891
98f5ce56 bca9-41ef-b8c9-095d7bf17a1c-151202050517-lva1-app689198f5ce56 bca9-41ef-b8c9-095d7bf17a1c-151202050517-lva1-app6891
98f5ce56 bca9-41ef-b8c9-095d7bf17a1c-151202050517-lva1-app6891
 
A model support plan for underground coal mines , under regulation 123 of the...
A model support plan for underground coal mines , under regulation 123 of the...A model support plan for underground coal mines , under regulation 123 of the...
A model support plan for underground coal mines , under regulation 123 of the...
 
Pharma catalogue 2017 18
Pharma catalogue 2017 18Pharma catalogue 2017 18
Pharma catalogue 2017 18
 
publication_1580218342.pdf
publication_1580218342.pdfpublication_1580218342.pdf
publication_1580218342.pdf
 
Consistency test,Initial & Final setting time of Hydraulic Cement specimen
Consistency test,Initial & Final setting time of Hydraulic Cement specimenConsistency test,Initial & Final setting time of Hydraulic Cement specimen
Consistency test,Initial & Final setting time of Hydraulic Cement specimen
 
PLAIN AND REINFORCED CONRETE (LAB MANUAL)
PLAIN AND REINFORCED CONRETE (LAB MANUAL)PLAIN AND REINFORCED CONRETE (LAB MANUAL)
PLAIN AND REINFORCED CONRETE (LAB MANUAL)
 
Lining in tunnels
Lining in tunnelsLining in tunnels
Lining in tunnels
 
Experimental Study of Improvement in Confinement of Reinforced Concrete Column
Experimental Study of Improvement in Confinement of Reinforced Concrete ColumnExperimental Study of Improvement in Confinement of Reinforced Concrete Column
Experimental Study of Improvement in Confinement of Reinforced Concrete Column
 
Instruction- 3 Core Polymeric (XLPE EPR) 6.6kV-7.2kV Heat Shrink Cable Termin...
Instruction- 3 Core Polymeric (XLPE EPR) 6.6kV-7.2kV Heat Shrink Cable Termin...Instruction- 3 Core Polymeric (XLPE EPR) 6.6kV-7.2kV Heat Shrink Cable Termin...
Instruction- 3 Core Polymeric (XLPE EPR) 6.6kV-7.2kV Heat Shrink Cable Termin...
 
Piezoelectric Diaphram Bulk Manufacturing_v7.5
Piezoelectric Diaphram Bulk Manufacturing_v7.5Piezoelectric Diaphram Bulk Manufacturing_v7.5
Piezoelectric Diaphram Bulk Manufacturing_v7.5
 
Inspecting Correctly Slide Show
Inspecting Correctly Slide ShowInspecting Correctly Slide Show
Inspecting Correctly Slide Show
 
BEHAVIOR OF CONCRETE WITH PARTIAL REPLACEMENT OF C- AGGREGATES BY GRANULATED ...
BEHAVIOR OF CONCRETE WITH PARTIAL REPLACEMENT OF C- AGGREGATES BY GRANULATED ...BEHAVIOR OF CONCRETE WITH PARTIAL REPLACEMENT OF C- AGGREGATES BY GRANULATED ...
BEHAVIOR OF CONCRETE WITH PARTIAL REPLACEMENT OF C- AGGREGATES BY GRANULATED ...
 
Ppt on test certificate-Amit Payal
Ppt on test certificate-Amit PayalPpt on test certificate-Amit Payal
Ppt on test certificate-Amit Payal
 
Sla user guide
Sla user guideSla user guide
Sla user guide
 

Recently uploaded

Top Rated Bangalore Call Girls Richmond Circle ⟟ 8250192130 ⟟ Call Me For Gen...
Top Rated Bangalore Call Girls Richmond Circle ⟟ 8250192130 ⟟ Call Me For Gen...Top Rated Bangalore Call Girls Richmond Circle ⟟ 8250192130 ⟟ Call Me For Gen...
Top Rated Bangalore Call Girls Richmond Circle ⟟ 8250192130 ⟟ Call Me For Gen...narwatsonia7
 
(Rocky) Jaipur Call Girl - 09521753030 Escorts Service 50% Off with Cash ON D...
(Rocky) Jaipur Call Girl - 09521753030 Escorts Service 50% Off with Cash ON D...(Rocky) Jaipur Call Girl - 09521753030 Escorts Service 50% Off with Cash ON D...
(Rocky) Jaipur Call Girl - 09521753030 Escorts Service 50% Off with Cash ON D...indiancallgirl4rent
 
Top Rated Bangalore Call Girls Mg Road ⟟ 8250192130 ⟟ Call Me For Genuine Sex...
Top Rated Bangalore Call Girls Mg Road ⟟ 8250192130 ⟟ Call Me For Genuine Sex...Top Rated Bangalore Call Girls Mg Road ⟟ 8250192130 ⟟ Call Me For Genuine Sex...
Top Rated Bangalore Call Girls Mg Road ⟟ 8250192130 ⟟ Call Me For Genuine Sex...narwatsonia7
 
Call Girls Service Jaipur Grishma WhatsApp ❤8445551418 VIP Call Girls Jaipur
Call Girls Service Jaipur Grishma WhatsApp ❤8445551418 VIP Call Girls JaipurCall Girls Service Jaipur Grishma WhatsApp ❤8445551418 VIP Call Girls Jaipur
Call Girls Service Jaipur Grishma WhatsApp ❤8445551418 VIP Call Girls Jaipurparulsinha
 
Top Quality Call Girl Service Kalyanpur 6378878445 Available Call Girls Any Time
Top Quality Call Girl Service Kalyanpur 6378878445 Available Call Girls Any TimeTop Quality Call Girl Service Kalyanpur 6378878445 Available Call Girls Any Time
Top Quality Call Girl Service Kalyanpur 6378878445 Available Call Girls Any TimeCall Girls Delhi
 
(👑VVIP ISHAAN ) Russian Call Girls Service Navi Mumbai🖕9920874524🖕Independent...
(👑VVIP ISHAAN ) Russian Call Girls Service Navi Mumbai🖕9920874524🖕Independent...(👑VVIP ISHAAN ) Russian Call Girls Service Navi Mumbai🖕9920874524🖕Independent...
(👑VVIP ISHAAN ) Russian Call Girls Service Navi Mumbai🖕9920874524🖕Independent...Taniya Sharma
 
Best Rate (Guwahati ) Call Girls Guwahati ⟟ 8617370543 ⟟ High Class Call Girl...
Best Rate (Guwahati ) Call Girls Guwahati ⟟ 8617370543 ⟟ High Class Call Girl...Best Rate (Guwahati ) Call Girls Guwahati ⟟ 8617370543 ⟟ High Class Call Girl...
Best Rate (Guwahati ) Call Girls Guwahati ⟟ 8617370543 ⟟ High Class Call Girl...Dipal Arora
 
Call Girls Varanasi Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Varanasi Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Varanasi Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Varanasi Just Call 9907093804 Top Class Call Girl Service AvailableDipal Arora
 
Call Girls Siliguri Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Siliguri Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Siliguri Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Siliguri Just Call 9907093804 Top Class Call Girl Service AvailableDipal Arora
 
Call Girls Faridabad Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Faridabad Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Faridabad Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Faridabad Just Call 9907093804 Top Class Call Girl Service AvailableDipal Arora
 
Book Paid Powai Call Girls Mumbai 𖠋 9930245274 𖠋Low Budget Full Independent H...
Book Paid Powai Call Girls Mumbai 𖠋 9930245274 𖠋Low Budget Full Independent H...Book Paid Powai Call Girls Mumbai 𖠋 9930245274 𖠋Low Budget Full Independent H...
Book Paid Powai Call Girls Mumbai 𖠋 9930245274 𖠋Low Budget Full Independent H...Call Girls in Nagpur High Profile
 
Night 7k to 12k Navi Mumbai Call Girl Photo 👉 BOOK NOW 9833363713 👈 ♀️ night ...
Night 7k to 12k Navi Mumbai Call Girl Photo 👉 BOOK NOW 9833363713 👈 ♀️ night ...Night 7k to 12k Navi Mumbai Call Girl Photo 👉 BOOK NOW 9833363713 👈 ♀️ night ...
Night 7k to 12k Navi Mumbai Call Girl Photo 👉 BOOK NOW 9833363713 👈 ♀️ night ...aartirawatdelhi
 
Call Girls Ooty Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Ooty Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Ooty Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Ooty Just Call 9907093804 Top Class Call Girl Service AvailableDipal Arora
 
Call Girls Dehradun Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Dehradun Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Dehradun Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Dehradun Just Call 9907093804 Top Class Call Girl Service AvailableDipal Arora
 
Bangalore Call Girls Nelamangala Number 7001035870 Meetin With Bangalore Esc...
Bangalore Call Girls Nelamangala Number 7001035870  Meetin With Bangalore Esc...Bangalore Call Girls Nelamangala Number 7001035870  Meetin With Bangalore Esc...
Bangalore Call Girls Nelamangala Number 7001035870 Meetin With Bangalore Esc...narwatsonia7
 
Call Girls Tirupati Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Tirupati Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Tirupati Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Tirupati Just Call 9907093804 Top Class Call Girl Service AvailableDipal Arora
 
The Most Attractive Hyderabad Call Girls Kothapet 𖠋 6297143586 𖠋 Will You Mis...
The Most Attractive Hyderabad Call Girls Kothapet 𖠋 6297143586 𖠋 Will You Mis...The Most Attractive Hyderabad Call Girls Kothapet 𖠋 6297143586 𖠋 Will You Mis...
The Most Attractive Hyderabad Call Girls Kothapet 𖠋 6297143586 𖠋 Will You Mis...chandars293
 
Call Girls Bhubaneswar Just Call 9907093804 Top Class Call Girl Service Avail...
Call Girls Bhubaneswar Just Call 9907093804 Top Class Call Girl Service Avail...Call Girls Bhubaneswar Just Call 9907093804 Top Class Call Girl Service Avail...
Call Girls Bhubaneswar Just Call 9907093804 Top Class Call Girl Service Avail...Dipal Arora
 
Call Girls Gwalior Just Call 8617370543 Top Class Call Girl Service Available
Call Girls Gwalior Just Call 8617370543 Top Class Call Girl Service AvailableCall Girls Gwalior Just Call 8617370543 Top Class Call Girl Service Available
Call Girls Gwalior Just Call 8617370543 Top Class Call Girl Service AvailableDipal Arora
 
Call Girls Coimbatore Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Coimbatore Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Coimbatore Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Coimbatore Just Call 9907093804 Top Class Call Girl Service AvailableDipal Arora
 

Recently uploaded (20)

Top Rated Bangalore Call Girls Richmond Circle ⟟ 8250192130 ⟟ Call Me For Gen...
Top Rated Bangalore Call Girls Richmond Circle ⟟ 8250192130 ⟟ Call Me For Gen...Top Rated Bangalore Call Girls Richmond Circle ⟟ 8250192130 ⟟ Call Me For Gen...
Top Rated Bangalore Call Girls Richmond Circle ⟟ 8250192130 ⟟ Call Me For Gen...
 
(Rocky) Jaipur Call Girl - 09521753030 Escorts Service 50% Off with Cash ON D...
(Rocky) Jaipur Call Girl - 09521753030 Escorts Service 50% Off with Cash ON D...(Rocky) Jaipur Call Girl - 09521753030 Escorts Service 50% Off with Cash ON D...
(Rocky) Jaipur Call Girl - 09521753030 Escorts Service 50% Off with Cash ON D...
 
Top Rated Bangalore Call Girls Mg Road ⟟ 8250192130 ⟟ Call Me For Genuine Sex...
Top Rated Bangalore Call Girls Mg Road ⟟ 8250192130 ⟟ Call Me For Genuine Sex...Top Rated Bangalore Call Girls Mg Road ⟟ 8250192130 ⟟ Call Me For Genuine Sex...
Top Rated Bangalore Call Girls Mg Road ⟟ 8250192130 ⟟ Call Me For Genuine Sex...
 
Call Girls Service Jaipur Grishma WhatsApp ❤8445551418 VIP Call Girls Jaipur
Call Girls Service Jaipur Grishma WhatsApp ❤8445551418 VIP Call Girls JaipurCall Girls Service Jaipur Grishma WhatsApp ❤8445551418 VIP Call Girls Jaipur
Call Girls Service Jaipur Grishma WhatsApp ❤8445551418 VIP Call Girls Jaipur
 
Top Quality Call Girl Service Kalyanpur 6378878445 Available Call Girls Any Time
Top Quality Call Girl Service Kalyanpur 6378878445 Available Call Girls Any TimeTop Quality Call Girl Service Kalyanpur 6378878445 Available Call Girls Any Time
Top Quality Call Girl Service Kalyanpur 6378878445 Available Call Girls Any Time
 
(👑VVIP ISHAAN ) Russian Call Girls Service Navi Mumbai🖕9920874524🖕Independent...
(👑VVIP ISHAAN ) Russian Call Girls Service Navi Mumbai🖕9920874524🖕Independent...(👑VVIP ISHAAN ) Russian Call Girls Service Navi Mumbai🖕9920874524🖕Independent...
(👑VVIP ISHAAN ) Russian Call Girls Service Navi Mumbai🖕9920874524🖕Independent...
 
Best Rate (Guwahati ) Call Girls Guwahati ⟟ 8617370543 ⟟ High Class Call Girl...
Best Rate (Guwahati ) Call Girls Guwahati ⟟ 8617370543 ⟟ High Class Call Girl...Best Rate (Guwahati ) Call Girls Guwahati ⟟ 8617370543 ⟟ High Class Call Girl...
Best Rate (Guwahati ) Call Girls Guwahati ⟟ 8617370543 ⟟ High Class Call Girl...
 
Call Girls Varanasi Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Varanasi Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Varanasi Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Varanasi Just Call 9907093804 Top Class Call Girl Service Available
 
Call Girls Siliguri Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Siliguri Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Siliguri Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Siliguri Just Call 9907093804 Top Class Call Girl Service Available
 
Call Girls Faridabad Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Faridabad Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Faridabad Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Faridabad Just Call 9907093804 Top Class Call Girl Service Available
 
Book Paid Powai Call Girls Mumbai 𖠋 9930245274 𖠋Low Budget Full Independent H...
Book Paid Powai Call Girls Mumbai 𖠋 9930245274 𖠋Low Budget Full Independent H...Book Paid Powai Call Girls Mumbai 𖠋 9930245274 𖠋Low Budget Full Independent H...
Book Paid Powai Call Girls Mumbai 𖠋 9930245274 𖠋Low Budget Full Independent H...
 
Night 7k to 12k Navi Mumbai Call Girl Photo 👉 BOOK NOW 9833363713 👈 ♀️ night ...
Night 7k to 12k Navi Mumbai Call Girl Photo 👉 BOOK NOW 9833363713 👈 ♀️ night ...Night 7k to 12k Navi Mumbai Call Girl Photo 👉 BOOK NOW 9833363713 👈 ♀️ night ...
Night 7k to 12k Navi Mumbai Call Girl Photo 👉 BOOK NOW 9833363713 👈 ♀️ night ...
 
Call Girls Ooty Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Ooty Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Ooty Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Ooty Just Call 9907093804 Top Class Call Girl Service Available
 
Call Girls Dehradun Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Dehradun Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Dehradun Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Dehradun Just Call 9907093804 Top Class Call Girl Service Available
 
Bangalore Call Girls Nelamangala Number 7001035870 Meetin With Bangalore Esc...
Bangalore Call Girls Nelamangala Number 7001035870  Meetin With Bangalore Esc...Bangalore Call Girls Nelamangala Number 7001035870  Meetin With Bangalore Esc...
Bangalore Call Girls Nelamangala Number 7001035870 Meetin With Bangalore Esc...
 
Call Girls Tirupati Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Tirupati Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Tirupati Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Tirupati Just Call 9907093804 Top Class Call Girl Service Available
 
The Most Attractive Hyderabad Call Girls Kothapet 𖠋 6297143586 𖠋 Will You Mis...
The Most Attractive Hyderabad Call Girls Kothapet 𖠋 6297143586 𖠋 Will You Mis...The Most Attractive Hyderabad Call Girls Kothapet 𖠋 6297143586 𖠋 Will You Mis...
The Most Attractive Hyderabad Call Girls Kothapet 𖠋 6297143586 𖠋 Will You Mis...
 
Call Girls Bhubaneswar Just Call 9907093804 Top Class Call Girl Service Avail...
Call Girls Bhubaneswar Just Call 9907093804 Top Class Call Girl Service Avail...Call Girls Bhubaneswar Just Call 9907093804 Top Class Call Girl Service Avail...
Call Girls Bhubaneswar Just Call 9907093804 Top Class Call Girl Service Avail...
 
Call Girls Gwalior Just Call 8617370543 Top Class Call Girl Service Available
Call Girls Gwalior Just Call 8617370543 Top Class Call Girl Service AvailableCall Girls Gwalior Just Call 8617370543 Top Class Call Girl Service Available
Call Girls Gwalior Just Call 8617370543 Top Class Call Girl Service Available
 
Call Girls Coimbatore Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Coimbatore Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Coimbatore Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Coimbatore Just Call 9907093804 Top Class Call Girl Service Available
 

ivoclar ips manual

  • 1. STEP-BY-STEP INSTRUCTIONS ON THE PROSTHETIC PROCEDURES Straumann® Anatomic IPS e.max® Abutment 15X.811.indd 1 09.10.12 11:40
  • 2. The ITI (International Team for Implantology) is academic partner of Institut Straumann in the areas of research and education. 15X.811.indd 2 09.10.12 11:40
  • 3. CONTENT Straumann® Anatomic IPS e.max®1 Abutment 2 1. Cement-retained crowns and bridges 3 1.1 Straumann® Anatomic IPS e.max®1 Abutment – Lab procedure 3 1.2 Straumann® Anatomic IPS e.max®1 Abutment – Prosthetic procedure 7 1.3 Straumann® Anatomic IPS e.max®1 Abutment – Chairside procedure for temporary restorations 8 2. Screw-retained crowns, directly veneered 12 2.1 Straumann® Anatomic IPS e.max®1 Abutment – Lab procedure 12 2.2 Straumann® Anatomic IPS e.max®1 Abutment – Prosthetic procedure 17 3. Screw-retained crowns using the press-on technique 18 3.1 Straumann® Anatomic IPS e.max®1 Abutment – Lab procedure 18 3.2 Straumann® Anatomic IPS e.max®1 Abutment – Prosthetic procedure 26 Important guidelines 27 15X.811.indd 1 09.10.12 11:40
  • 4. 2 STRAUMANN® ANATOMIC IPS e.max®1 ABUTMENT Intended use p Cement-retained crowns and bridges via mesostructure – Conventional procedure – Temporary restoration chairside p Screw-retained crowns – Direct veneering (with IPS e.max® Ceram1 ) – Press-on technique (with IPS e.max® ZirPress1 ) Material p Zirconium dioxide Characteristics Simple p Processing of a highly esthetic ceramic abutment in different colors with conventional lab methods p Less grinding necessary due to prepared mucosa margins p Adaptation to natural soft tissue contour due to prepared mucosa margins in different heights p Oval shape resembles emergence profile of a natural tooth Reliable p Biocompatible and low thermal conductivity p High-performance all-ceramics thanks to a high strength and high fracture toughness p Reduced risk of margins shining through the soft tissue even with thin mucosa biotype p CrossFit® Connection p Precise fit Note Only use an original Straumann® basal screw for ceramic abutment for the final insertion of the Straumann® Anatomic IPS e.max®1 Abutment. The Straumann® Anatomic IPS e.max®1 Abutment is available in the following shades: MO 0 and MO 1 (MO = Medium Opacity). Recommendations regard- ing the sterilization procedure can be found in the instructions for use. Straumann® Anatomic IPS e.max® Abutment 15X.811.indd 2 09.10.12 11:40
  • 5. 1c 1a 1b 3 1.1 Straumann® Anatomic IPS e.max®1 Abutment – Lab procedure The following case describes the fabrication of a cement-retained crown by using the Straumann® Anatomic IPS e.max®1 Abutment. Step 1 – Fabricating the master cast and wax-up p Fabricate the master cast including a gingival mask with the corresponding implant analog (see instructions in chapter 5 in brochure Art. No. 152.810). p For optimal esthetic planning, design a full anatomical wax-up. p Make a silicone key over the full wax-up in order to define the optimal shape of the modified abutment. 1. CEMENT-RETAINED CROWNS AND BRIDGES 1. Cement-retained crowns and bridges Cement-retained restorations need to fulfill the following criteria (see 2c): p Individualized abutments must have cusp and marginal ridge support. p The maximum thickness of the veneering material on top of the coping must not exceed a maximum of 2.0 mm in all directions. p Avoid any sharp edges. 15X.811.indd 3 09.10.12 11:40
  • 6. 2c 2a 2b NC NC RC RC 2 mm 16 mm 16 mm 2 mm 2 mm 16 mm 16 mm 2 mm NC GH 2 mm RC GH 2 mm 4 Step 2 – Preparing the Straumann® Anatomic IPS e.max®1 Abutment p Place the abutment on the polishing aid/analog and hand tighten the screw using the SCS screwdriver. p For the individualization of the Straumann® Anatomic IPS e.max®1 Abutment, it is recommended to work with a water-cooled turbine and abrasive instruments that are ap- propriate for grinding sintered ZrO2 material. Work with a low grinding pressure and avoid any spark formation. The Ivoclar Vivadent grinding instrument recommendations for IPS e.max®1 must be followed. Note In order to keep sufficient stability of the abutment, do not deviate from the dimensions shown in the following graphics (2c). The height of the abutment must achieve at least 65 % of the complete restoration. p The final geometry of the abutment has to meet the require- ments of the material of the final restoration for cement- retained crowns and bridges. 1. Cement-retained crowns and bridges Cemented 0.3 mm 1.3 mm min. 4 mm 0.5 mm 3.5 mm min. 4 mm 0.75 mm 0.5 mm 1.3 mm min. 4 mm 0.75 mm 0.5 mm 3.5 mm min. 4 mm NC GH 3.5 mm RC GH 3.5 mm 15X.811.indd 4 09.10.12 11:40
  • 7. 3a 2d 3b 5 Step 3 – Fabricating the superstructure p Use a standard procedure to fabricate the ceramic coping with the Straumann® CARES® Scan CS2 scanner and the Straumann® CARES® Visual software. p Following the Ivoclar Vivadent grinding instrument rec- ommendations for IPS e.max®1 a regeneration firing for cement-retained crowns and bridges is not required. The regeneration firing has to be conducted if the Ivoclar Vivadent grinding instrument recommendations for IPS e.max®1 are not followed or if a further thermal processing is necessary. The regeneration firing parameter are: 65 °C (117 °F) per minute heating up to 1050 °C (1922 °F) / 15 minute hold- ing time and long-term cooling down with 25 °C (45 °F) per minute to 750 °C (1382 °F). 1. Cement-retained crowns and bridges p Veneer the coping with conventional veneering material synchronized to the thermal expansion coefficient of the ceramic coping. p Coefficient of thermal expansion2 (CTE) (100–500 °C) 10.80±0.25 10-6 K-1 p For veneering follow the recommendations of the ceramic material manufacturer. 15X.811.indd 5 09.10.12 11:40
  • 8. 3c 3d 6 Note In case of adhesive bonding, sandblast the portions of the abutment surface which will be covered with cement with Al2 O3 (type 100 microns) at 0.5–1.0 bar (15–30 psi). While sandblasting, the implant configuration must be protected with the polishing aid. 1. Cement-retained crowns and bridges 15X.811.indd 6 09.10.12 11:41
  • 9. 2a 2b 7 Step 1 – Preparation p Remove the healing cap or temporary restoration. p Remove the superstructure from the master cast and unscrew the abutment from the analog. p Clean and dry the interior of the implant and the abutment thoroughly. p Prepare the surface of the abutment corresponding to the cementation material which will be used (e.g. in case of adhesive bonding apply primer). p Condition the inner surface of the superstructure according to the instructions for use given by the according manufacturer (e.g. in case of adhesive bonding apply primer). 1.2 Straumann® Anatomic IPS e.max®1 Abutment – Prosthetic procedure The final restoration is delivered to the doctor’s office on the master cast. Step 2 – Final insertion p Position the cleaned abutment in the implant. Tighten the screw to 35 Ncm using the SCS screwdriver along with the ratchet and the torque control device (see instructions in chapter 7.5 in brochure Art. No. 152.810). p Close the SCS screw channel with cotton and sealing compound (i.e. gutta-percha). This allows for later re- moval of the modified abutment in the event a restoration replacement is required. p Cement the superstructure onto the abutment. p Remove any excess cement. Note Only use an original Straumann® basal screw for ceramic abutment for the final insertion of the Straumann® Anatomic IPS e.max®1 Abutment. 1. Cement-retained crowns and bridges 15X.811.indd 7 09.10.12 11:41
  • 10. 1b 1a NC NC RC RC 2 mm 16 mm 16 mm 2 mm 16 mm 16 mm 2 mm NC GH 2 mm RC GH 2 mm 2 mm 88 1.3 Straumann® Anatomic IPS e.max®1 Abutment – Chairside procedure for temporary restorations The following case describes the usage of the Straumann® Anatomic IPS e.max®1 Abutment chairside. Step 1 – Preparing the Straumann® Anatomic IPS e.max®1 Abutment p For the individualization of the Straumann® Anatomic IPS e.max®1 Abutment, it is recommended to work with a water- cooled turbine and abrasive instruments that are appropri- ate for grinding sintered ZrO2 material. Work with a low grinding pressure and avoid any spark formation. The Ivo- clar Vivadent grinding instrument recommendations for IPS e.max®1 must be followed. Note In order to keep sufficient stability of the abutment, do not deviate from the dimensions shown in the following graphics (1b). The height of the abutment must achieve at least 65 % of the complete restoration. p The final geometry of the abutment has to meet the require- ments of the material of the final restoration for cement- retained crowns and bridges. 1. Cement-retained crowns and bridges Cemented 0.3 mm 1.3 mm min. 4 mm 0.5 mm 3.5 mm min. 4 mm 0.75 mm 0.5 mm 1.3 mm min. 4 mm 0.75 mm 0.5 mm 3.5 mm min. 4 mm NC GH 3.5 mm RC GH 3.5 mm 15X.811.indd 8 09.10.12 11:41
  • 11. 1c 2b 2a 99 p Following the Ivoclar Vivadent grinding instrument rec- ommendations for IPS e.max®1 a regeneration firing for cement-retained crowns and bridges is not required. The regeneration firing has to be conducted if the Ivoclar Viva- dent grinding instrument recommendations for IPS e.max®1 are not followed or if a further thermal processing is neces- sary. The regeneration firing parameter are: 65 °C (117 °F) per minute heating up to 1050 °C (1922 °F) / 15 minute holding time and long-term cooling down with 25 °C (45 °F) per minute to 750 °C (1382 °F). 1. Cement-retained crowns and bridges Step 2 – Placing the modified Straumann® Anatomic IPS e.max®1 Abutment p Place the abutment on the implant and tighten the screw with a torque between 15 Ncm and 35 Ncm using the SCS screwdriver along with the ratchet and the torque control device (see instructions in chapter 7.5 in brochure Art. No. 152.810). Note Before taking the abutment level impression the abutment needs to be torqued with 35 Ncm. p Cover the screw head with absorbent cotton or gutta-percha and seal the screw channel temporarily (e.g. with absorbent cotton). 15X.811.indd 9 09.10.12 11:41
  • 12. 2c 4 3 10 p Take an impression with an individualized impression tray and order the final restoration. 1. Cement-retained crowns and bridges Step 3 – Fabricating the cement-retained temporary single crown Use a standard procedure to fabricate the cement-retained single crown (e.g. grind out a prefabricated plastic tooth). Step 4 – Cementing the temporary single crown p Coat the internal configuration of the crown with temporary cement and cement it onto the Straumann® Anatomic IPS e.max®1 Abutment. p Remove any excess cement. 15X.811.indd 10 09.10.12 11:42
  • 13. 5a 5b 111. Cement-retained crowns and bridges Step 5 – Insertion of the final restoration p Remove the temporary restoration. p Clean and dry the interior of the abutment thoroughly. p Close the SCS screw channel with cotton and sealing com- pound (i.e. gutta-percha). This allows for later removal of the modified abutment in the event a restoration replacement is required. p Cement the superstructure onto the abutment. p Remove any excess cement. 15X.811.indd 11 09.10.12 11:42
  • 14. 1c 1b 1a 12 2. Screw-retained crowns, directly veneered 2.1 Straumann® Anatomic IPS e.max®1 Abutment – Lab procedure The following case describes the fabrication of screw-retained crowns directly veneered, when using the Straumann® Anatomic IPS e.max®1 Abutment and IPS e.max® Ceram1 . Step 1 – Fabricating the master cast and wax-up p Fabricate the master cast including a gingival mask with the corresponding implant analog (see instructions in chapter 5 in brochure Art. No. 152.810). p For optimal esthetic planning, design a full anatomical wax-up. p Make a silicone key over the full wax-up in order to define the optimal shape of the modified abutment. 2. SCREW-RETAINED CROWNS, DIRECTLY VENEERED Screw-retained restorations need to fulfill the following criteria (see 2c): p In the anterior region, screw hole access must be located in the palatal/lingual area of the restoration. p The screw hole position in the incisal or labial area is contraindicated. p In the posterior area, screw hole position must be located in the center of the occlusal area of the restoration. p Before veneering or press-on procedure the individualized abutment must have a reduced anatomically supporting design (cusp and marginal support). p The maximum thickness of the veneering material on top of the individualized abutments (layering ceramic and/or press-on ceramic) must not exceed a maximum of 2.0 mm in all directions of the screw retained restoration. 15X.811.indd 12 09.10.12 11:43
  • 15. 2a 2b 132. Screw-retained crowns, directly veneered Step 2 – Preparing the Straumann® Anatomic IPS e.max®1 Abutment p Place the abutment on the polishing aid/analog and hand tighten the screw using the SCS screwdriver. p For the individualization of the Straumann® Anatomic IPS e.max®1 Abutment, it is recommended to work with a water-cooled turbine and abrasive instruments that are ap- propriate for grinding sintered ZrO2 material. Work with a low grinding pressure and avoid any spark formation. The Ivoclar Vivadent grinding instrument recommendations for IPS e.max®1 must be followed. 15X.811.indd 13 09.10.12 11:43
  • 16. 2c 2d NC NC RC RC 2 mm 16 mm 16 mm 2 mm 2 mm 16 mm 16 mm 2 mm NC GH 2 mm RC GH 2 mm 14 Note In order to keep sufficient stability of the abutment, do not deviate from the dimensions shown in the following graphics (2c). The height of the abutment must achieve at least 65 % of the complete restoration. p The final geometry of the abutment has to meet the require- ments of the veneering material. 2. Screw-retained crowns, directly veneered p After grinding and/or polishing the abutment a regenera- tion firing has to be conducted in a firing furnace: 65 °C (117 °F) per minute heating up to 1050 °C (1922 °F) / 15 minutes holding time and long-term cooling down with 25 °C (45 °F) per minute to 750 °C (1382 °F). Directly veneered max. 2 mm max. 2 mm max. 2 mm max. 2 mm max. 2 mm max. 2 mm max. 2 mm 0.3 mm 1.3 mm min. 4 mm 0.5 mm 3.5 mm min. 4 mm 0.75 mm 0.5 mm 1.3 mm min. 4 mm 0.75 mm 0.5 mm 3.5 mm min. 4 mm NC GH 3.5 mm RC GH 3.5 mm 15X.811.indd 14 09.10.12 11:43
  • 17. 3a 3b 3c 152. Screw-retained crowns, directly veneered Step 3 – Veneering p For the veneering of the Straumann® Anatomic IPS e.max®1 Abutment, use conventional veneering material synchronized to the thermal expansion coefficient of the abutment. p Coefficient of thermal expansion2 (CTE) (100–500 °C) 10.80±0.25 10-6 K-1 p In this case IPS e.max® Ceram1 has been used. For fur- ther details please consult the brochure “Instructions for use IPS e.max® Ceram1 ” (www.ivoclarvivadent.com). p Steam clean the abutment and apply the IPS e.max® Ceram ZirLiner1 only where IPS e.max® Ceram1 will be applied later on. p The implant configuration must be protected with the polish- ing aid while applying the IPS e.max® Ceram ZirLiner1 . Note Do not sandblast the abutment before applying the IPS e.max® Ceram Liner1 . Avoid any application of IPS e.max® Ceram ZirLiner1 into the screw channel. Note Do not apply IPS e.max® Ceram ZirLiner1 on the inner con- figuration. In case of an adaptation of the emergence profile it is recommended to place the abutment upside down on the firing tray to prevent the ZirLiner1 from flowing towards the inner configuration during firing. 15X.811.indd 15 09.10.12 11:43
  • 18. 3f 3e 3d 16 2. Screw-retained crowns, directly veneered p Particular attention must be given to an even layer thickness of the porcelain veneered on the abutment. Note Observe the maximum thickness of the layering ceramic material (max. 2 mm). p Final restoration 15X.811.indd 16 09.10.12 11:44
  • 19. 2a 2b 172. Screw-retained crowns, directly veneered 2.2 Straumann® Anatomic IPS e.max®1 Abutment – Prosthetic procedure The final restoration is delivered to the doctor’s office on the master cast. Step 1 – Preparation p Remove the healing cap or temporary restoration. p Remove the veneered abutment from the master cast. p Clean and dry the interior of the implant and the abutment thoroughly. Step 2 – Final insertion p Position the cleaned and veneered abutment in the implant. Tighten the screw to 35 Ncm using the SCS screwdriver along with the ratchet and the torque control device (see instruction in chapter 7.5, in brochure Art. No. 152.810). p Close the SCS screw channel with cotton and sealing com- pound (i.e. gutta-percha, composite). This allows for later removal of the modified abutment in the event a restoration replacement is required. Note Only use an original Straumann® basal screw for ceramic abutment for the final insertion of the Straumann® Anatomic IPS e.max®1 Abutment. 15X.811.indd 17 09.10.12 11:44
  • 20. 1c 1b 1a 18 3. Screw-retained crowns using the press-on technique 3.1 Straumann® Anatomic IPS e.max®1 Abutment – Lab procedure The following case describes the fabrication of a screw-retained crown when using the Straumann® Anatomic IPS e.max®1 Abutment in combination with the press-on technique. In this case IPS e.max® ZirPress1 has been used. Step 1 – Fabricating the master cast and wax-up p Fabricate the master cast including a gingival mask with the correspondingimplantanalog(seeinstructionsinchapter5in brochure Art. No. 152.810). p For optimal esthetic planning, design a full anatomical wax-up. p Make a silicone key over the full wax-up in order to define the optimal shape of the modified abutment. 3. SCREW-RETAINED CROWNS USING THE PRESS-ON TECHNIQUE Screw-retained restorations need to fulfill the following criteria (see 2c): p In the anterior region, screw hole access must be located in the palatal/lingual area of the restoration. p The screw hole position in the incisal or labial area is contraindicated. p In the posterior area, screw hole position must be located in the center of the occlusal area of the restoration. p Before veneering or press-on procedure the individualized abutment must have a reduced anatomically supporting design (cusp and marginal support). p The maximum thickness of the veneering material on top of the individualized abutments (layering ceramic and/or press-on ceramic) must not exceed a maximum of 2.0 mm in all directions of the screw retained restoration. 15X.811.indd 18 09.10.12 11:44
  • 21. 2a 2b 193. Screw-retained crowns using the press-on technique Step 2 – Preparing the Straumann® Anatomic IPS e.max®1 Abutment p Place the abutment on the polishing aid/analog and hand tighten the screw using the SCS screwdriver. p For the individualization of the Straumann® Anatomic IPS e.max®1 Abutment, it is recommended to work with a water-cooled turbine and abrasive instruments that are ap- propriate for grinding sintered ZrO2 material. Work with a low grinding pressure and avoid any spark formation. The Ivoclar Vivadent grinding instrument recommendations for IPS e.max®1 must be followed. 15X.811.indd 19 09.10.12 11:44
  • 22. 2c 2d NC NC RC RC NC GH 2 mm RC GH 2 mm 2 mm 16 mm 2 mm 16 mm 16 mm 2 mm 16 mm 2 mm 20 3. Screw-retained crowns using the press-on technique Note In order to keep sufficient stability of the abutment, do not deviate from the dimensions shown in the following graphics (2c). The height of the abutment must achieve at least 65 % of the complete restoration. p The final geometry of the abutment has to meet the require- ments of the framework and veneering material. p After grinding and/or polishing the abutment a regeneration firing has to be conducted in a firing furnace: 65 °C (117 °F) per minute heating up to 1050 °C (1922 °F)/15 minutes holding time and long-term cooling down with 25 °C (45 °F) per minute to 750 °C (1382 °F). max. 2 mm max. 2 mm max. 2 mm max. 2 mm max. 2 mm max. 2 mm max. 2 mm Directly veneered 0.3 mm 1.3 mm min. 4 mm 0.5 mm 3.5 mm min. 4 mm 0.75 mm 0.5 mm 1.3 mm min. 4 mm 0.75 mm 0.5 mm 3.5 mm min. 4 mm NC GH 3.5 mm RC GH 3.5 mm 15X.811.indd 20 09.10.12 11:44
  • 23. 3a 3b 3c 213. Screw-retained crowns using the press-on technique Step 3 – Process of press-on technique p For pressing onto the Straumann® Anatomic IPS e.max®1 Abutment, use conventional press-on material synchronized to the thermal expansion coefficient of the abutment. p Coefficient of thermal expansion2 (CTE) (100–500 °C) 10.80±0.25 10-6 K-1 p In this case IPS e.max® ZirPress1 has been used. For fur- ther details please consult the brochure “Instructions for use IPS e.max® ZirPress1 ” (www.ivoclarvivadent.com). p Steam clean the abutment and apply the IPS e.max® Ceram ZirLiner1 only where IPS e.max® ZirPress1 will be applied later on. p The implant configuration must be protected with the polish- ing aid while applying the IPS e.max® Ceram ZirLiner1 . Note Do not sandblast the abutment before applying the IPS e.max® Ceram Liner1 . Avoid any application of IPS e.max® Ceram ZirLiner1 into the screw channel. Note Do not apply IPS e.max® Ceram ZirLiner1 on the inner con- figuration. In case of an adaptation of the emergence profile it is recommended to place the abutment upside down on the firing tray to prevent the ZirLiner1 from flowing towards the inner configuration during firing. 15X.811.indd 21 09.10.12 11:45
  • 24. 3d 3f 3e 22 3. Screw-retained crowns using the press-on technique Note In order to prevent IPS e.max® ZirPress1 to intrude into the screw channel of the abutment do not cover the screw channel with wax. p Sprueing p Observe the respective material thickness (minimum 0.7 mm up to 2 mm) in order to ensure a proper press-on restora- tion. 15X.811.indd 22 09.10.12 11:45
  • 25. 3h 3j 3i 3g 233. Screw-retained crowns using the press-on technique p Cover the whole abutment with investment material and ensure that the screw channel is also completely filled. p Before pressing, ensure that the pressing furnace is suffi- ciently preheated. p The implant configuration must be protected with the polishing aid (e. g. sandblasting). 15X.811.indd 23 09.10.12 11:46
  • 26. 3m 3l 3k 24 3. Screw-retained crowns using the press-on technique Note The long-term success of the prosthetic work depends on the accurate fit of the restoration. Therefore the following recom- mendations must be observed: p Allow for enough cooling time of the press-on abutment before divestment p Rough divestment is carried out with glass polishing beads at 4 bar (60 psi) pressure p Fine divestment is carried out with glass polishing beads at 2 bar (30 psi) pressure p Do not use Al2 O3 for rough or fine divestment p Do not sandblast the conical portion of the abutment and always protect the implant/abutment interface with the polishing aid p Immerse the pressed objects into the IPS e.max® Press Invex Liquid1 (min. 5 minutes, max. 10 minutes) and ensure that they are completely covered. p Carefully remove the white reaction layer on the pressed ob- jects with Al2 O3 (type 100 microns) at 1–2 bar (15–30 psi) pressure. 15X.811.indd 24 09.10.12 11:46
  • 27. 3n 3o 253. Screw-retained crowns using the press-on technique p Veneer, shade and glaze the restoration according to the individual situation. Note The implant configuration must be protected with the polishing aid while applying the IPS e.max® Ceram1 . p Final restoration 15X.811.indd 25 09.10.12 11:46
  • 28. 2a 2b 26 3. Screw-retained crowns using the press-on technique Step 1 – Preparation p Remove the healing cap or temporary restoration. p Remove the overpressed abutment from the master cast. p Clean and dry the interior of the implant and the abutment thoroughly. Step 2 – Final insertion p Position the cleaned abutment in the implant. Tighten the screw to 35 Ncm using the SCS screwdriver along with the ratchet and the torque control device (see instructions in chapter 7.5 in brochure Art. No. 152.810). p Close the SCS screw channel with cotton and sealing com- pound (i.e. gutta-percha, composite). This allows a later removal of the modified abutment in the event a restoration replacement is required. Note Only use an original Straumann® basal screw for ceramic abutment for the final insertion of the Straumann® Anatomic IPS e.max®1 Abutment. 3.2 Straumann® Anatomic IPS e.max®1 Abutment – Prosthetic procedure The final restoration is delivered to the doctor’s office on the master cast. 15X.811.indd 26 09.10.12 11:47
  • 29. 27 Please note Practitioners must have appropriate knowledge and instruction in the handling of the Straumann CADCAM products or other Straumann products (“Straumann Products”) for using the Straumann Products safely and properly in accordance with the instructions for use. The Straumann Product must be used in accordance with the instructions for use provided by the manufacturer. It is the practitioner’s responsibility to use the device in accordance with these instructions for use and to determine, if the device fits to the individual patient situation. The Straumann Products are part of an overall concept and must be used only in conjunction with the corresponding original components and instruments distributed by Institut Straumann AG, its ultimate parent company and all affiliates or subsidiaries of such parent company (“Straumann”), except if stated otherwise in this document or in the instructions for use for the respective Straumann Product. If use of products made by third parties is not recommended by Straumann in this document or in the respective instructions for use, any such use will void any warranty or other obligation, express or implied, of Straumann. Availability Some of the Straumann Products listed in this document may not be available in all countries. Caution In addition to the caution notes in this document, our products must be secured against aspiration when used intraorally. Validity Upon publication of this document, all previous versions are superseded. Documentation For detailed instructions on the Straumann Products contact your Straumann representative. Copyright and trademarks Straumann® documents may not be reprinted or published, in whole or in part, without the written authorization of Straumann. Straumann® and/or other trademarks and logos from Straumann® mentioned herein are the trademarks or registered trademarks of Straumann Holding AG and/or its affiliates. Explanation of the symbols on labels and instruction leaflets IMPORTANT GUIDELINES Batch code Catalogue number Sterilized using irradiation …min. Lower limit of temperature …max. Upper limit of temperature …max. …min. Temperature limitation Caution: Federal law restricts this device to sale by or on the order of a dental professional. Do not re-use Non-sterile Caution, consult accompanying documents Use by Keep away from sunlight Straumann Products with the CE mark fulfill the requirements of the Medical Devices Directive 93/42 EEC 0123 Consult instructions for use IMPORTANT GUIDELINES 15X.811.indd 27 09.10.12 11:47
  • 30. 28 Straumann® Anatomic IPS e.max®1 Abutment is avaible in the following shades: MO 0 and MO 1 (MO = Medium Opacity) 1 IPS e.max® , IPS e.max® Ceram, IPS e.max® ZirPress, IPS e.max® Ceram ZirLiner, IPS e.max® Ceram Liner, IPS e.max® Press Invex Liquid are registered trademarks of Ivoclar Vivadent AG, Liechtenstein 2 Ivoclar Vivadent AG, Liechtenstein 15X.811.indd 28 09.10.12 11:47
  • 32. International Headquarters Institut Straumann AG Peter Merian-Weg 12 CH-4002 Basel, Switzerland Phone +41 (0)61 965 11 11 Fax +41 (0)61 965 11 01 www.straumann.com StraumannproductsareCEmarked    10/12  152.811/en    BG21012 © Institut Straumann AG, 2012. All rights reserved. Straumann® and/or other trademarks and logos from Straumann® mentioned herein are the trademarks or registered trademarks of Straumann Holding AG and/or its affiliates. All rights reserved.