Fiber Optic
Chlorophyll
Analyzer
MODEL NO
VEFOC1008
The Fiber-optic Chlorophyll Analyzer adopts the principle of fluorescence method. According
to the spectral absorption characteristics of chlorophyll a, the water body is irradiated by a
high-energy LED light source, and the chlorophyll a in the water body is excited to generate
fluorescence of a specific wavelength, and the concentration of chlorophyll a in the water is
measured. The sensor's fiber-optic structure provides excellent repeatability and stability and
is less susceptible to ambient light. With an automatic cleaning brush to eliminate air bubbles,
reduce the impact of contamination on the measurement, make the maintenance cycle longer,
and maintain excellent stability for long-term online use.
Fiber Optic
Chlorophyll
Analyzer
VASTHI INSTRUMENTS
Plot no:21&22, Block no:24, Phase-IV
Feature
 Digital sensor, RS-485 output, support MODBUS.
 Automatic cleaning brush to prevent contamination and eliminate air
bubbles
 Direct measurement is easier than traditional analysis methods
 Continuous online monitoring and real-time control of water quality
Technical Specifications
Product name Fiber Optic Chlorophyll
Analyzer
Self-cleaning Chlorophyll
Analyzer
Model VEFOC1008A VEFOC1008B
Principle Fluorescence method
Range 0~400 ug/L or 0 ~100 RFU
Resolution 0.1μg/L or 0.1% RFU
Linearity R2>0.99
temperature range 0~ 50°C
Protection level Ip68
Depth 60m Max 10m Max
Sensor interface Support RS-485, MODBUS protocol
assembly Input type
Power information DC 5~12V, I<50mA DC 5~12V, I<50mA (Without
wiping)
Probe cable length 10 meters (default), can be customized
Dimension Φ22*120 mm Φ33*156mm
Housing material SS316 (customizable titanium alloy)
Optical window optical fiber
Self-cleaning
system
no Yes
Auto Nagar, Guntur-522001. Andhra Pradesh, India.
Tel:+91 863 2253 667, +91 738 2708 685, +91 958 1678 685
web: www. vasthi. com, E:info@vasthi.com.

Fiber Optic Chlorophyll Analyzer.pdf

  • 1.
    Fiber Optic Chlorophyll Analyzer MODEL NO VEFOC1008 TheFiber-optic Chlorophyll Analyzer adopts the principle of fluorescence method. According to the spectral absorption characteristics of chlorophyll a, the water body is irradiated by a high-energy LED light source, and the chlorophyll a in the water body is excited to generate fluorescence of a specific wavelength, and the concentration of chlorophyll a in the water is measured. The sensor's fiber-optic structure provides excellent repeatability and stability and is less susceptible to ambient light. With an automatic cleaning brush to eliminate air bubbles, reduce the impact of contamination on the measurement, make the maintenance cycle longer, and maintain excellent stability for long-term online use. Fiber Optic Chlorophyll Analyzer
  • 2.
    VASTHI INSTRUMENTS Plot no:21&22,Block no:24, Phase-IV Feature  Digital sensor, RS-485 output, support MODBUS.  Automatic cleaning brush to prevent contamination and eliminate air bubbles  Direct measurement is easier than traditional analysis methods  Continuous online monitoring and real-time control of water quality Technical Specifications Product name Fiber Optic Chlorophyll Analyzer Self-cleaning Chlorophyll Analyzer Model VEFOC1008A VEFOC1008B Principle Fluorescence method Range 0~400 ug/L or 0 ~100 RFU Resolution 0.1μg/L or 0.1% RFU Linearity R2>0.99 temperature range 0~ 50°C Protection level Ip68 Depth 60m Max 10m Max Sensor interface Support RS-485, MODBUS protocol assembly Input type Power information DC 5~12V, I<50mA DC 5~12V, I<50mA (Without wiping) Probe cable length 10 meters (default), can be customized Dimension Φ22*120 mm Φ33*156mm Housing material SS316 (customizable titanium alloy) Optical window optical fiber Self-cleaning system no Yes Auto Nagar, Guntur-522001. Andhra Pradesh, India. Tel:+91 863 2253 667, +91 738 2708 685, +91 958 1678 685 web: www. vasthi. com, E:info@vasthi.com.