SlideShare a Scribd company logo
24.05.2011
2007             Eltec System

                                                                Eikelaarstraat 17
       1997         Eltec System                                B-3600 Genk
                                                                Opp.:1600m2
                    Eikelaarstraat 17                                                                    2011 – 2012
                                                                Employees: 40
                    B-3600 Genk                                                                          New concept!
                    Opp.: + 600m2
                    Employees: 10




1994                                                                                New Plant 06/2008
        Establishment Eltec System
                                     2001                                              Troisdorfstraat
        Joe Huygen                          Expansion Eltec System                       B-3600 Genk
        Sabine Hahn
                                                                                        Opp.:4000 m²
        Bedrijvencentrum                    Eikelaarstraat 17
                                                                                      Total: 10000 m²
        B-3600 Genk                         B-3600 Genk
                                                                                        Employees:46
        Opp.: 100m2                         Opp.: 1600m2
                                            Employees: 18
Repairs


Field Service


Sales


Motormanagement


EGS Program
gespecialiseerd service onderhoud herstelling industriële aandrijvingen pompen partner
herwikkelen sturingen Maintenance sales productgroep spares montage olie dichtingen
remmen laswerken retrofit trillingsanalyse veiligheid certificaten klant optimaliseren doel
productie registratie know how onderhoudskosten koolborstels sturingen ac lagers preventief
demontage tools balanceren draaiwerk werkomgeving eltec2.0 mechatronisch ondersteuning
gespecialiseerd service onderhoud herstelling industriële aandrijvingen pompen partner
herwikkelen sturingen Maintenance sales productgroep spares montage olie dichtingen
remmen laswerken retrofit trillingsanalyse    veiligheid certificaten klant optimaliseren doel
productie registratie know how onderhoudskosten koolborstels sturingen ac lagers preventief
demontage        tools     balanceren      draaiwerk       werkomgeving         mechatronisch
ondersteuninggespecialiseerd service onderhoud herstelling industriële aandrijvingen pompen
partner herwikkelen sturingen Maintenance sales productgroep spares montage olie
dichtingen remmen laswerken retrofit         trillingsanalyse veiligheid certificaten klant
optimaliseren doel productie
Eltec2.0




    Many think green , we act green !
Eltec2.0




   • 65% van alle energie wordt verbruikt door elektrische motors

   • €1 gespendeerd aan de aankoop van een motor ,worden er €100 gespendeerd aan
     het verbruik over de levensduur ervan !
Eltec2.0



           Besparen ?
               Investering ?
           Verplicht ?
                  Hoe ??
            Waarom ?
            Waar Hoeveel
                  ? ?
              Waarmee
Eltec2.0EGS Program




                       EGS Program
                       Eltec Green Screening
Eltec2.0EGS Program




International Efficiency   VSD / Softstarters   Energy Efficient     Downsizing
           IE                                       Repairs        Re-engineering
                                                                    Retrofitting
Eltec2.0EGS ProgramInternational Efficiency IE



     16 juni 2011     Geen motoren meer worden verkocht met een lagere efficiëntie dan rendementsklasse
                      IE2, wat impliceert dat de huidige klassen EFF2-3 niet langer verkrijgbaar zullen zijn


     1 januari 2015   Alleen nog IE3-motoren worden toegestaan voor direct online- werking, hoewel IE 2-motoren
                      uitgerust met aandrijvingen voor variabele snelheden worden toegestaan voor het
                      vermogenbereik 7,5 - 375 kW


     1 januari 2017   Dezelfde regel van toepassing op het volledige vermogenbereik, gaande van 0,75 kW
                      tot 375 kW
Eltec2.0EGS ProgramInternational Efficiency IE
                 Motor Details                         Motor 1                Motor 2                Motor 3                Motor 4                      Motor 5                 Motor 6
True Cost per kWh                                          0.2                    0.2                    0.2                    0.2                          0.2                     0.2
Speed (rpm)                                              1500                   1500                   1500                   1500                         1500                    1500
Rated output (kW)                                           90                     22                     15                     15                           11                      11
Load Point                                                  75                     75                     75                     75                           75                      75
No of hours run per day                                     24                     24                     24                     24                           24                      24
No of days run per week                                      7                      7                      7                      7                            7                       7
No of weeks run per year                                    40                     40                     40                     40                           40                      40
No of motors                                                 1                      1                      1                      1                            1                       1
No hours                                                 6720                   6720                   6720                   6720                         6720                    6720
              Benefits of IE2 Motor                    Motor 1                Motor 2                Motor 3                Motor 4                      Motor 5                 Motor 6

Efficiency @ Load Point of Std IE1 motor                     92                   90.7                   89.8                   89.8                         88                        88
Annual run cost of Std motor                            98,609                  24,45                 16,837                 16,837                        12,6                      12,6
Efficiency @ Load Point of IE2 motor                       95.1                   92.9                   92.3                   92.3                       91.2                      91.2
Annual run cost of IE2 motor                            95,394                 23,871                 16,381                 16,381                      12,158                   12,158
Siemens motor type                         1LG6283-4MA-60-ZA11    1LG6186-4MA-60-ZA11    1LE1001-1DB4-3-4AB0    1LE1001-1DB4-3-4AB0      1LE1001-1DB2-3-4AB0         1LE1001-1DB2-3-4AB0
Annual savings with IE2 motor                           3.215 €                 579 €                   456 €                  456 €                      442 €                     442 €
                                                                                                                                           Total anual savings :               5.590,00 €

                                                                                                                                         Total savings / hours :                   0,83 €
Purchase price IE1 ( Siemens )                          3.930 €                1.023 €                  711 €                  711 €                      549 €                  549,00 €

Purchase price IE2 ( Siemens )                          4.470 €                1.287 €                  933 €                  933 €                        732 €                732,00 €
                                                                                                                                                           Total:              9.087,00 €
                                                                                                                               ROI ( complete changeover IE2 )                  455 days
Investment / motor                                        540 €                  264 €                  222 €                  222 €                        183 €                     183
                                                                                                                                                           Total:              1.614,00 €
                                                                                                                                     ROI ( extra price IE2 / IE1 )                81 days
Eltec2.0EGS ProgramVSD . Softstarters
            Current

                                                                                       – Reduced start current
       8                                                                               – No hydraulic shocks
       7                                                                               – Smaller fuses and cables
                      DOL Start                                                          – nominal motor current
       6

       5
                             Y/D Start           Voltage/current                       – Less mechanical stress
                                                 control softstarter
   I/IN 4                                                                              – Reduced installation costs
       3
                                                   Torque control softstarter          – PFC: Power Factor Control
       2
                                                                                       – Smaller energy bills
       1


       0                 2               4   6             8           10       Time
Eltec2.0EGS ProgramEnergy Efficient Repairs


 Onze herstelling zal niet onderdoen voor nieuw materiaal !

 Integendeel , Eltec geeft als het ware een upgrade aan uw meest waarde volle aandrijving door enkel gebruik te maken van
 hoogwaardige materialen en onderdelen.

 Het gebruik van “ SKF Energy Efficient Bearings” en een precisie balancering volgens de DIN 1940 met als maatstaf G2.5 als
 groene leidraad door elke herstelling heen.
Eltec2.0EGS ProgramDownsizing . Re-engineering . Retrofitting




                             Total Drive Train Concept
EltecFoto’sRetrofit SVEX Antwerpen
EltecFoto’sRetrofit DP World Antwerpen
EltecFoto’sRetrofit DP World Antwerpen
EltecFoto’sRetrofit DP World Antwerpen
EltecFoto’sRetrofit DP World Antwerpen
EltecFoto’sRetrofit DP World Antwerpen
EltecFoto’sRetrofit DP World Antwerpen
EltecFoto’sRetrofit DP World Antwerpen
www.eltec.be   2011

More Related Content

Similar to Eltec - Company Presentation

Ecomobiel Euro Rally Colt - samenwerken is samen winnen
Ecomobiel Euro Rally Colt - samenwerken is samen winnen Ecomobiel Euro Rally Colt - samenwerken is samen winnen
Ecomobiel Euro Rally Colt - samenwerken is samen winnen
HANduurzaam
 
Duurzaam De Toepassing Van Ethanol, Scania
Duurzaam   De Toepassing Van Ethanol, ScaniaDuurzaam   De Toepassing Van Ethanol, Scania
Duurzaam De Toepassing Van Ethanol, Scania
Hans Mestrum videofilm expert
 
Ontwikkeling alternatieve WKK voor biogas.
Ontwikkeling alternatieve WKK voor biogas.Ontwikkeling alternatieve WKK voor biogas.
Ontwikkeling alternatieve WKK voor biogas.
HANduurzaam
 
Produceer met minder engergie doordachte selectie van aandrijfcomponenten v...
Produceer met minder engergie   doordachte selectie van aandrijfcomponenten v...Produceer met minder engergie   doordachte selectie van aandrijfcomponenten v...
Produceer met minder engergie doordachte selectie van aandrijfcomponenten v...Sirris
 
Eltec - Stockbeheer in crisistijd
Eltec - Stockbeheer in crisistijdEltec - Stockbeheer in crisistijd
Eltec - Stockbeheer in crisistijd
haraldvandenbranden
 

Similar to Eltec - Company Presentation (6)

Ecomobiel Euro Rally Colt - samenwerken is samen winnen
Ecomobiel Euro Rally Colt - samenwerken is samen winnen Ecomobiel Euro Rally Colt - samenwerken is samen winnen
Ecomobiel Euro Rally Colt - samenwerken is samen winnen
 
Duurzaam De Toepassing Van Ethanol, Scania
Duurzaam   De Toepassing Van Ethanol, ScaniaDuurzaam   De Toepassing Van Ethanol, Scania
Duurzaam De Toepassing Van Ethanol, Scania
 
Ontwikkeling alternatieve WKK voor biogas.
Ontwikkeling alternatieve WKK voor biogas.Ontwikkeling alternatieve WKK voor biogas.
Ontwikkeling alternatieve WKK voor biogas.
 
Senertec dachs
Senertec dachsSenertec dachs
Senertec dachs
 
Produceer met minder engergie doordachte selectie van aandrijfcomponenten v...
Produceer met minder engergie   doordachte selectie van aandrijfcomponenten v...Produceer met minder engergie   doordachte selectie van aandrijfcomponenten v...
Produceer met minder engergie doordachte selectie van aandrijfcomponenten v...
 
Eltec - Stockbeheer in crisistijd
Eltec - Stockbeheer in crisistijdEltec - Stockbeheer in crisistijd
Eltec - Stockbeheer in crisistijd
 

Eltec - Company Presentation

  • 2. 2007 Eltec System Eikelaarstraat 17 1997 Eltec System B-3600 Genk Opp.:1600m2 Eikelaarstraat 17 2011 – 2012 Employees: 40 B-3600 Genk New concept! Opp.: + 600m2 Employees: 10 1994 New Plant 06/2008 Establishment Eltec System 2001 Troisdorfstraat Joe Huygen Expansion Eltec System B-3600 Genk Sabine Hahn Opp.:4000 m² Bedrijvencentrum Eikelaarstraat 17 Total: 10000 m² B-3600 Genk B-3600 Genk Employees:46 Opp.: 100m2 Opp.: 1600m2 Employees: 18
  • 4.
  • 5.
  • 6.
  • 7.
  • 8. gespecialiseerd service onderhoud herstelling industriële aandrijvingen pompen partner herwikkelen sturingen Maintenance sales productgroep spares montage olie dichtingen remmen laswerken retrofit trillingsanalyse veiligheid certificaten klant optimaliseren doel productie registratie know how onderhoudskosten koolborstels sturingen ac lagers preventief demontage tools balanceren draaiwerk werkomgeving eltec2.0 mechatronisch ondersteuning gespecialiseerd service onderhoud herstelling industriële aandrijvingen pompen partner herwikkelen sturingen Maintenance sales productgroep spares montage olie dichtingen remmen laswerken retrofit trillingsanalyse veiligheid certificaten klant optimaliseren doel productie registratie know how onderhoudskosten koolborstels sturingen ac lagers preventief demontage tools balanceren draaiwerk werkomgeving mechatronisch ondersteuninggespecialiseerd service onderhoud herstelling industriële aandrijvingen pompen partner herwikkelen sturingen Maintenance sales productgroep spares montage olie dichtingen remmen laswerken retrofit trillingsanalyse veiligheid certificaten klant optimaliseren doel productie
  • 9.
  • 10. Eltec2.0 Many think green , we act green !
  • 11. Eltec2.0 • 65% van alle energie wordt verbruikt door elektrische motors • €1 gespendeerd aan de aankoop van een motor ,worden er €100 gespendeerd aan het verbruik over de levensduur ervan !
  • 12. Eltec2.0 Besparen ? Investering ? Verplicht ? Hoe ?? Waarom ? Waar Hoeveel ? ? Waarmee
  • 13. Eltec2.0EGS Program EGS Program Eltec Green Screening
  • 14. Eltec2.0EGS Program International Efficiency VSD / Softstarters Energy Efficient Downsizing IE Repairs Re-engineering Retrofitting
  • 15. Eltec2.0EGS ProgramInternational Efficiency IE 16 juni 2011 Geen motoren meer worden verkocht met een lagere efficiëntie dan rendementsklasse IE2, wat impliceert dat de huidige klassen EFF2-3 niet langer verkrijgbaar zullen zijn 1 januari 2015 Alleen nog IE3-motoren worden toegestaan voor direct online- werking, hoewel IE 2-motoren uitgerust met aandrijvingen voor variabele snelheden worden toegestaan voor het vermogenbereik 7,5 - 375 kW 1 januari 2017 Dezelfde regel van toepassing op het volledige vermogenbereik, gaande van 0,75 kW tot 375 kW
  • 16. Eltec2.0EGS ProgramInternational Efficiency IE Motor Details Motor 1 Motor 2 Motor 3 Motor 4 Motor 5 Motor 6 True Cost per kWh 0.2 0.2 0.2 0.2 0.2 0.2 Speed (rpm) 1500 1500 1500 1500 1500 1500 Rated output (kW) 90 22 15 15 11 11 Load Point 75 75 75 75 75 75 No of hours run per day 24 24 24 24 24 24 No of days run per week 7 7 7 7 7 7 No of weeks run per year 40 40 40 40 40 40 No of motors 1 1 1 1 1 1 No hours 6720 6720 6720 6720 6720 6720 Benefits of IE2 Motor Motor 1 Motor 2 Motor 3 Motor 4 Motor 5 Motor 6 Efficiency @ Load Point of Std IE1 motor 92 90.7 89.8 89.8 88 88 Annual run cost of Std motor 98,609 24,45 16,837 16,837 12,6 12,6 Efficiency @ Load Point of IE2 motor 95.1 92.9 92.3 92.3 91.2 91.2 Annual run cost of IE2 motor 95,394 23,871 16,381 16,381 12,158 12,158 Siemens motor type 1LG6283-4MA-60-ZA11 1LG6186-4MA-60-ZA11 1LE1001-1DB4-3-4AB0 1LE1001-1DB4-3-4AB0 1LE1001-1DB2-3-4AB0 1LE1001-1DB2-3-4AB0 Annual savings with IE2 motor 3.215 € 579 € 456 € 456 € 442 € 442 € Total anual savings : 5.590,00 € Total savings / hours : 0,83 € Purchase price IE1 ( Siemens ) 3.930 € 1.023 € 711 € 711 € 549 € 549,00 € Purchase price IE2 ( Siemens ) 4.470 € 1.287 € 933 € 933 € 732 € 732,00 € Total: 9.087,00 € ROI ( complete changeover IE2 ) 455 days Investment / motor 540 € 264 € 222 € 222 € 183 € 183 Total: 1.614,00 € ROI ( extra price IE2 / IE1 ) 81 days
  • 17. Eltec2.0EGS ProgramVSD . Softstarters Current – Reduced start current 8 – No hydraulic shocks 7 – Smaller fuses and cables DOL Start – nominal motor current 6 5 Y/D Start Voltage/current – Less mechanical stress control softstarter I/IN 4 – Reduced installation costs 3 Torque control softstarter – PFC: Power Factor Control 2 – Smaller energy bills 1 0 2 4 6 8 10 Time
  • 18. Eltec2.0EGS ProgramEnergy Efficient Repairs Onze herstelling zal niet onderdoen voor nieuw materiaal ! Integendeel , Eltec geeft als het ware een upgrade aan uw meest waarde volle aandrijving door enkel gebruik te maken van hoogwaardige materialen en onderdelen. Het gebruik van “ SKF Energy Efficient Bearings” en een precisie balancering volgens de DIN 1940 met als maatstaf G2.5 als groene leidraad door elke herstelling heen.
  • 19. Eltec2.0EGS ProgramDownsizing . Re-engineering . Retrofitting Total Drive Train Concept
  • 28. www.eltec.be 2011