DYX-302 Coverlever-type weighing sensor
Features:
·High stability
·The structure is highly low
·The comprehensive accuracy is high
·Anti-interference signals are stable
·Quality alloy steel with nickel plating
·widely used in electronic belt scale,
packaging scale, filling scale
In the equal weighing equipment.And the
automation equipment field and testing
Trial field.
qualification
Rated quantitative schedule T 0-5
Output sensitivity mV/V 2.0±0.02
Zero point output %F.S. ±1
Non-linear %F.S. 0.03
lag %F.S. 0.03
Repeatability %F.S. 0.02
Creep (30 min) %F.S. 0.02
Temperature sensitivity drift %F.S./10℃ 0.03
Zero temperature drift %F.S./10℃ 0.03
Response frequency Hz 1k
Material 42CrMoA
impedance Ω 350
Insulation resistance MΩ/100V DC ≥5000
Use voltage V 5-15
Operating temperature range ℃ -20-80
Safety overload %R.C. 150
Extreme overload %R.C. 300
Cable line specifications m Φ5*5m
Cable limit pull force N 98
TEDS selectable
1) High temperature sensors are available, with a maximum operating temperature of 150℃.
2) High impedance sensors can be provided with an output impedance of 1000 Ω.
https://www.loadcells.store
DAYSENSOR
Product Size Fig
Unit: mm
Range L L1 L2 L3 L4 L5 W1 H H1 φD ΦD1 φD2
0.5-2T 203 95 26 22 98 64 36.5 43 30.4 16 32 13
3T 203 95 26 22 98 64 36.5 43 30.4 16 32 15
5T 234 110 26 22 124 66 47.5 52 30 22 38 20
force diagram
Pressure points or support feet shall be added to the force point

DYX-302.pdf

  • 1.
    DAYSENSOR DYX-302 Coverlever-type weighingsensor Features: ·High stability ·The structure is highly low ·The comprehensive accuracy is high ·Anti-interference signals are stable ·Quality alloy steel with nickel plating ·widely used in electronic belt scale, packaging scale, filling scale In the equal weighing equipment.And the automation equipment field and testing Trial field. qualification Rated quantitative schedule T 0-5 Output sensitivity mV/V 2.0±0.02 Zero point output %F.S. ±1 Non-linear %F.S. 0.03 lag %F.S. 0.03 Repeatability %F.S. 0.02 Creep (30 min) %F.S. 0.02 Temperature sensitivity drift %F.S./10℃ 0.03 Zero temperature drift %F.S./10℃ 0.03 Response frequency Hz 1k Material 42CrMoA impedance Ω 350 Insulation resistance MΩ/100V DC ≥5000 Use voltage V 5-15 Operating temperature range ℃ -20-80 Safety overload %R.C. 150 Extreme overload %R.C. 300 Cable line specifications m Φ5*5m Cable limit pull force N 98 TEDS selectable 1) High temperature sensors are available, with a maximum operating temperature of 150℃. 2) High impedance sensors can be provided with an output impedance of 1000 Ω. https://www.loadcells.store
  • 2.
    DAYSENSOR Product Size Fig Unit:mm Range L L1 L2 L3 L4 L5 W1 H H1 φD ΦD1 φD2 0.5-2T 203 95 26 22 98 64 36.5 43 30.4 16 32 13 3T 203 95 26 22 98 64 36.5 43 30.4 16 32 15 5T 234 110 26 22 124 66 47.5 52 30 22 38 20 force diagram Pressure points or support feet shall be added to the force point