KÜÇÜK SİSTEMLERDE FONKSİYONGRAFİĞİ
Saatlik tüketim, gaz basıncı ve sıcaklığı
Tüketim ortalama 40 sm3/h ve maksimumda 92 sm3/h olurken, gaz sıcaklıkları 10-40
‘C arasında değişmiş, 1. Kademe çıkışındaki gaz basıncı ise ani çekiş artışları veya
palet basıncının düşmesi sebebi ile 6.5 ile 9.5 bar arasında değiştiğini görüyoruz.
0
10
20
30
40
50
60
70
80
90
100
4/8/20168:00:00AM
4/22/20164:00:00PM
4/24/20166:00:00PM
4/26/20168:00:00PM
4/28/201610:00:00PM
5/1/201612:00:00AM
5/3/20162:00:00AM
5/5/20164:00:00AM
5/7/20166:00:00AM
5/9/20168:00:00AM
5/11/201610:00:00AM
5/13/201612:00:00PM
5/15/20162:00:00PM
5/17/20166:00:00PM
5/19/20168:00:00PM
5/21/201610:00:00PM
5/24/201612:00:00AM
5/26/20162:00:00AM
5/28/20164:00:00AM
5/30/20166:00:00AM
6/1/20169:00:00AM
6/3/201611:00:00AM
6/5/20161:00:00PM
6/7/20163:00:00PM
6/9/20165:00:00PM
6/11/20167:00:00PM
m3/s
T [hr_avg]
P [hr_avg]
ORTA BOY FONKSİYONGRAFİĞİ
Saatlik tüketim, gaz basıncı ve sıcaklığı
Saatlik tüketimin tek gün için 5.14.2016 Saat 12:00 am de 421 sm3 olması haricinde
200 sm3 civarında sabit olduğu görülüyor. Bu esnada gaz sıcaklıkları 10 -25 ‘ C
arasında, gaz basıncının ise 5-7 bar arasında olduğu. 6.6.2016 6:00 am de gazın
bittiği ve yedeklerin açıldığı görülmektedir.
0
50
100
150
200
250
300
350
400
450
5/1/20169:00:00AM
5/2/20169:00:00PM
5/6/20169:00:00PM
5/8/20169:00:00AM
5/9/20169:00:00PM
5/11/20169:00:00AM
5/12/20169:00:00PM
5/14/20163:00:00PM
5/16/201612:00:00PM
5/18/201612:00:00AM
5/19/201612:00:00PM
5/21/201612:00:00AM
5/22/201612:00:00PM
5/24/20162:00:00PM
5/26/20162:00:00AM
5/27/20162:00:00PM
5/29/20162:00:00AM
5/30/20162:00:00PM
6/1/20163:00:00AM
6/2/20163:00:00PM
6/4/20163:00:00AM
6/5/20163:00:00PM
6/7/20163:00:00AM
6/8/20163:00:00PM
6/10/20168:00:00AM
6/11/20168:00:00PM
6/13/20166:00:00PM
m3/s
10*P(bar)
10*T('C)
BÜYÜK BOY FONKSİYONGRAFİĞİ
Saatlik tüketim, gaz basıncı ve sıcaklığı;
Tesisatta saatte 1700 sm3 gaz yakıldığı görülmektedir. Gaz sıcaklığı 10-35 ‘C
arasında değişmiş. 1. Kademe gaz basıncı 6.5 – 9 bar arasında kalmış.
0
500
1000
1500
2000
2500
3000
3500
4000
4500
3/7/201611:00:00AM
3/9/20167:00:00PM
3/14/201611:00:00AM
3/18/20163:00:00AM
3/20/201611:00:00AM
3/22/20167:00:00PM
3/25/20164:00:00AM
3/27/201612:00:00PM
3/29/20168:00:00PM
4/1/20164:00:00AM
4/3/201612:00:00PM
4/5/20168:00:00PM
4/8/20164:00:00AM
4/10/201612:00:00PM
4/13/20161:00:00PM
4/17/20165:00:00AM
4/19/20161:00:00PM
4/21/20169:00:00PM
4/24/20165:00:00AM
4/26/20169:00:00PM
4/29/20165:00:00AM
5/1/20161:00:00PM
5/3/20169:00:00PM
5/6/20167:00:00AM
5/8/20163:00:00PM
5/10/201611:00:00PM
M3/S
100*P [hr_avg]
100*T [hr_avg]
7.
GAZ ISITMALI EXSİSTEMLER.
Isıtma sistemi olarak elektrik ısıtıcıları yerine teki yedek olmak üzere 2 adet kombi
kullanılmıştır. Isıtma maliyeti 1/3 oranına inmiştir.
9.
KUYUDAN CNG ÜRETİMİ
TransatlanticYıldırım 1
Arar Petrol Hamam Sahası
Önde görülen boru tipi slug catcher, derin deniz sondajlarında kullanılanlardan
esinlenmiştir.
10.
YANGIN SUYU İLEGAZ SOĞUTMA SİSTEMİ
5 Mayıs tarihinde çalışmaya başlayan sistem gaz sıcaklıklarını 15 derece
düşürmüştür.
-5
0
5
10
15
20
25
30
35
40
45
Ölçüm…
2.4.20…
3.4.20…
4.4.20…
5.4.20…
7.4.20…
8.4.20…
9.4.20…
10.4.2…
12.4.2…
14.4.2…
15.4.2…
18.4.2…
19.4.2…
20.4.2…
21.4.2…
22.4.2…
24.4.2…
26.4.2…
27.4.2…
28.4.2…
29.4.2…
30.4.2…
1.5.20…
3.5.20…
4.5.20…
5.5.20…