2. Matrix
Linear attenuation coefficient
CT number and Unit
Window Level and Window Width
Different grey scales
CT post contrast enhancement
3. The image is represented as matrix of numbers
The 2D array of numbers arranged in rows or
columns
3D-voxel
2D-pixel
4. Fraction of a beam of x-rays that is absorbed or
scattered per unit thickness of absorber
-CT images are a display of amount of attenuation
when x ray beam penetrate body
5. The density measurement of this attenuated
beam is assigned a number.
Each pixel has a number which represents the
xray attenuation in corresponding voxel of
object.
6. This CT Number is
compared with
attenuation value of
water and displayed on
a scale of units called
Hounsfield unit.
This scale assigns water
as an attenuation
value(HU) as zero.
CT number-2000
Where +1000 (white)to -
1000(black) at either end
of spectrum
7. Window level –central
HU of all the numbers
within the window
width
Window width-covers
HU of all the tissues
of interest as shades of
gray(CT number
outside as black
/white)
8.
9. HYPODENSE HYPERDENSE
AIR
FAT
FLUID
GLIOSIS
VASOGENIC AND
CYTOTOXIC
EDEMA
BONE
ACUTE BLEED
METALLIC IMPLANTS
CALCULI-RENAL
ISODENSE
SUBACUTE
HAEMATOMA