RESIDENTIAL FIRE PROTECTION
F O R A L I F E T I M E
THE IDEAL
RETROFIT AND
NEW BUILD FIRE
PROTECTION
SOLUTION FOR
HELPING YOUR
COMPANY
GROW AND BE
SUCCESSFUL
T E C H N O L O G Y Y O U C A N T R U S T
Since 1984, BlazeMaster® Fire Sprinkler Systems have
provided fire protection to commercial and residential
properties across the U.K. These properties include,
but are not limited to, the high rise Callow Mount
retrofit project in Sheffield and many of the pilot
projects in Wales responding to legislation for all new
homes to be sprinkler protected.
A F F O R D A B L E
& R E L I A B L E
F I R E
P R O T E C T I O N
P R O D U C T F E AT U R E S
& B E N E F I T S
 Technology composed of flame-resistant
pipe engineered for ease of installation and
dependability.
 One-step joining system for reduced
labour costs.
 Eliminates the need for costly tools
and equipment.
 Proven resistance to corrosion
in all environments.
 Expert consultation regarding
compliance withlocal,regional and national
codes.
 Hands-on training and installation
available to alinstallers.
AVA I L A B I L I T Y A N D S I Z I N G
BlazeMaster® Fire Sprinkler Systems are available
worldwide through a network of manufacturers.
S I Z I N G
 Pipe: ASTM F442 in ¾" to 3" or
20mmto 76mm(SDR13.5 Iron Pipe Size)
 Fittings:ASTM F437or F438 in ¾" to 1¼"
or 20mmto32mm;ASTM F439 in 1½"to 3" or
38mm to 76mm
L I S T I N G S , A P P R O VA L S
A N D A P P L I C AT I O N S
BlazeMaster® Pipe & Fittings are UL listed, FM
Global and LPCB approved, and WRAS certified for
residential applications.
B S 9 2 5 1 : 2 0 1 4
BlazeMaster® Fire Sprinkler Systems can be
used in all three categories of system under BS
9251:2014fromsinglefamilydwellingsandHMO’s
up to care homes, student accommodation and
high-rise residential blocks.
A D VA N TA G E S O V E R
S T E E L
 Fits into tighter
spaces faster,easierand
quieter. Ideal for retrofits.
 Consistent
Hazen- WiliamsC Factor
of 150.
Steel hasa
starting C Factor of 120 but is
susceptible to corrosion over
time lowering thisfigure.


Lower environmental impact.
Easy to handle — no
specialtransportequipment
required.


Faster, cleaner installation.
Resistant to corrosion,
eveninsaltair environments.
B L A Z E M A S T E R
P I P E & F I T T I N G S
P E R F O R M A N C E IS
U N M AT C H E D
 BlazeMaster®
pioneered the use of non-
metallic fire sprinkler
systems.
 Higher impact
resistance onfittings and
higher level ASTM Material
classification over alternative
CPVC.
 FBC System
Compatible program offers
authoritative source on
chemical compatibility with
ancillary products.

Comprehensive
training andinstallation
process.
I N S TA L L AT I O N
CPVC
 Quick and simple installation
 Hand tools only, no power source
needed
 Solvent cement only, no heat
required
 Easy fit in tight spaces
PP-R



Costly power tools and electrical source required
Requires additional space
Takes longer to install
P I P E D I A M E T E R
1 " / 2 5 m m P P - R p i p e
1 " / 2 5 m m B l a z e M a s t e r p i p e
L A R G E R ID = B E T T E R F L O W
Because of the strength of its material,
BlazeMaster® Fire Sprinkler Systems have a
larger ID than PP-R pipe of the same diameter.
Delivering a better flow rate at smaller pipe size
which results in cost savings.
P P - R
PP-R fusion welding causes bead formation
in pipes, which can lead to reduced flow rate,
friction and increases potential for deposits.
O T H E R
A D VA N TA G E S
O V E R P P - R


No need for Hot Works permit.
FM approved for
concealedandexposed
(residential) applications.
 In the event of
a fire, will notsustain a flame
and is not combustible.

Comprehensive
instalationtraining andfree
consulting.
 BlazeMaster® Fire
Sprinkler Systems are UL listed
andWRAS approved for potable
water applications.
BEN EFITS O F A B L A Z E M A S T E R ®
FIRE S P R I N K L E R S Y S T E M
E N V I R O N M E N TA L I M PA C T
A study completed by FM Global and the Home Fire
Sprinkler Coalition in April 2010 lists the key benefits
of using a BlazeMaster® Fire SprinklerSystem.
 98% fewer greenhouse gases
released byburningbuildings
97% less overall fire damage
90% less water used to fight residential


fires
P R O T E C T I N G A G A I N S T
T H E D A N G E R S O F
M O D E R N H O M E
C O N S T R U C T I O N
Over the last 25 years, homes have been
built more economically, utilizing lightweight
construction techniques and products. While
cost-effective, this method can lead to a much
faster burn time and greater destruction of
property.
 A BlazeMaster® Fire Sprinkler
System reactsquicklyand provides additional
escape time from burning structures.

Increases
chance ofsurvival by
80%.*
 Reduces
property lossby70%.*
A S P R I N K L E R
S Y S T E M
I N C R E A S E S
C H A N C E
O F S U R V I VA L
B Y 8 0 % A N D
R E D U C E S
P R O P E R T Y
L O S S B Y 70%. *
*Fire Sprinkler Initiative: firesprinklerinitiative.org
T H E T R U T H A B O U T
B L A Z E M A S T E R ®
FIRE P R O T E C T I O N
S Y S T E M S
M I S C O N C E P T I O N F A C T
“When a fire occurs,
every sprinkler will go
off and ruin the whole
house.”
Only the fire sprinkler
closest to the fire wall will
activate. Approximately
85% of the time, just one
sprinkler operates.
“Burnt toast could set
them off.”
Sprinkler heads are not
triggered by smoke,
they activate only when
they sense extreme
temperatures between
135°F and 165°F (57°C
and 74°C).
“They’re ugly − they’ll ruin
the look of the house.”
New sprinkler models
can be mounted flush
with walls or ceilings
and concealed behind
decorative coverings.
A D D I T I O N A L R E S O U R C E S
British Automatic Fire Sprinkler Association: bafsa.org.uk
National Fire Sprinkler Network: nfsn.co.uk
European Fire Sprinkler Network: eurosprinkler.org
F B C S Y S T E M
C O M PAT IB L E
A range of ancillary products are tested
to ensure chemical compatibility with
BlazeMaster® Pipe and Fittings, including
thread sealants, construction materials and
firestops.
Visit FBCSystemCompatible.com for a
full list of compatible products and proceed
with confidence.
T R A I N I N G & E D U C AT I O N
To ensure proper installation, BlazeMaster®
Fire Sprinker Systems offer comprehensive
in-person and online training for installers,
contractors, engineers and construction
managers. Training covers cutting and
joining, listings and approvals, chemical
compatibility, best practices, health and
safety and more. Those who successfully
complete the course receive a BlazeMaster
training card and certificate of completion.
M A N U FA C T U R I N G N E T W O R K
BlazeMaster® Fire Protection Systemspartners with the top pipeandfittings manufacturersacross
the globe to ensure quality control and meet the most rigid specifications.
DELIVERING RELIABILITY.
F O R LIFE.
Visit blazemaster.eu or call 00 44 (0)1332 842211
or email blazemaster.emena@lubrizol.com to
contact a piping systems consultant.
The information contained herein is reliable based on current information but the advertiser makes
no representations, guarantees or warranties, express or implied, including any implied warranties of
merchantability or fitness for a particular purpose, or regarding the completeness, accuracy, or timeliness of
any information. Always consult your pipe and/or fitting manufacturer for current recommendations.
©The Lubrizol Corporation 2017, all rights reserved.
All marks are property of The Lubrizol Corporation,
a Berkshire Hathaway Company.
17-93972
Rev October 2017 - EU

Bm uk residential brochure

  • 1.
    RESIDENTIAL FIRE PROTECTION FO R A L I F E T I M E THE IDEAL RETROFIT AND NEW BUILD FIRE PROTECTION SOLUTION FOR HELPING YOUR COMPANY GROW AND BE SUCCESSFUL
  • 2.
    T E CH N O L O G Y Y O U C A N T R U S T Since 1984, BlazeMaster® Fire Sprinkler Systems have provided fire protection to commercial and residential properties across the U.K. These properties include, but are not limited to, the high rise Callow Mount retrofit project in Sheffield and many of the pilot projects in Wales responding to legislation for all new homes to be sprinkler protected. A F F O R D A B L E & R E L I A B L E F I R E P R O T E C T I O N P R O D U C T F E AT U R E S & B E N E F I T S  Technology composed of flame-resistant pipe engineered for ease of installation and dependability.  One-step joining system for reduced labour costs.  Eliminates the need for costly tools and equipment.  Proven resistance to corrosion in all environments.  Expert consultation regarding compliance withlocal,regional and national codes.  Hands-on training and installation available to alinstallers. AVA I L A B I L I T Y A N D S I Z I N G BlazeMaster® Fire Sprinkler Systems are available worldwide through a network of manufacturers. S I Z I N G  Pipe: ASTM F442 in ¾" to 3" or 20mmto 76mm(SDR13.5 Iron Pipe Size)  Fittings:ASTM F437or F438 in ¾" to 1¼" or 20mmto32mm;ASTM F439 in 1½"to 3" or 38mm to 76mm
  • 3.
    L I ST I N G S , A P P R O VA L S A N D A P P L I C AT I O N S BlazeMaster® Pipe & Fittings are UL listed, FM Global and LPCB approved, and WRAS certified for residential applications. B S 9 2 5 1 : 2 0 1 4 BlazeMaster® Fire Sprinkler Systems can be used in all three categories of system under BS 9251:2014fromsinglefamilydwellingsandHMO’s up to care homes, student accommodation and high-rise residential blocks. A D VA N TA G E S O V E R S T E E L  Fits into tighter spaces faster,easierand quieter. Ideal for retrofits.  Consistent Hazen- WiliamsC Factor of 150. Steel hasa starting C Factor of 120 but is susceptible to corrosion over time lowering thisfigure.   Lower environmental impact. Easy to handle — no specialtransportequipment required.   Faster, cleaner installation. Resistant to corrosion, eveninsaltair environments. B L A Z E M A S T E R P I P E & F I T T I N G S P E R F O R M A N C E IS U N M AT C H E D  BlazeMaster® pioneered the use of non- metallic fire sprinkler systems.  Higher impact resistance onfittings and higher level ASTM Material classification over alternative CPVC.  FBC System Compatible program offers authoritative source on chemical compatibility with ancillary products.  Comprehensive training andinstallation process.
  • 4.
    I N STA L L AT I O N CPVC  Quick and simple installation  Hand tools only, no power source needed  Solvent cement only, no heat required  Easy fit in tight spaces PP-R    Costly power tools and electrical source required Requires additional space Takes longer to install P I P E D I A M E T E R 1 " / 2 5 m m P P - R p i p e 1 " / 2 5 m m B l a z e M a s t e r p i p e L A R G E R ID = B E T T E R F L O W Because of the strength of its material, BlazeMaster® Fire Sprinkler Systems have a larger ID than PP-R pipe of the same diameter. Delivering a better flow rate at smaller pipe size which results in cost savings. P P - R PP-R fusion welding causes bead formation in pipes, which can lead to reduced flow rate, friction and increases potential for deposits. O T H E R A D VA N TA G E S O V E R P P - R   No need for Hot Works permit. FM approved for concealedandexposed (residential) applications.  In the event of a fire, will notsustain a flame and is not combustible.  Comprehensive instalationtraining andfree consulting.  BlazeMaster® Fire Sprinkler Systems are UL listed andWRAS approved for potable water applications.
  • 5.
    BEN EFITS OF A B L A Z E M A S T E R ® FIRE S P R I N K L E R S Y S T E M E N V I R O N M E N TA L I M PA C T A study completed by FM Global and the Home Fire Sprinkler Coalition in April 2010 lists the key benefits of using a BlazeMaster® Fire SprinklerSystem.  98% fewer greenhouse gases released byburningbuildings 97% less overall fire damage 90% less water used to fight residential   fires P R O T E C T I N G A G A I N S T T H E D A N G E R S O F M O D E R N H O M E C O N S T R U C T I O N Over the last 25 years, homes have been built more economically, utilizing lightweight construction techniques and products. While cost-effective, this method can lead to a much faster burn time and greater destruction of property.  A BlazeMaster® Fire Sprinkler System reactsquicklyand provides additional escape time from burning structures.  Increases chance ofsurvival by 80%.*  Reduces property lossby70%.* A S P R I N K L E R S Y S T E M I N C R E A S E S C H A N C E O F S U R V I VA L B Y 8 0 % A N D R E D U C E S P R O P E R T Y L O S S B Y 70%. * *Fire Sprinkler Initiative: firesprinklerinitiative.org
  • 6.
    T H ET R U T H A B O U T B L A Z E M A S T E R ® FIRE P R O T E C T I O N S Y S T E M S M I S C O N C E P T I O N F A C T “When a fire occurs, every sprinkler will go off and ruin the whole house.” Only the fire sprinkler closest to the fire wall will activate. Approximately 85% of the time, just one sprinkler operates. “Burnt toast could set them off.” Sprinkler heads are not triggered by smoke, they activate only when they sense extreme temperatures between 135°F and 165°F (57°C and 74°C). “They’re ugly − they’ll ruin the look of the house.” New sprinkler models can be mounted flush with walls or ceilings and concealed behind decorative coverings. A D D I T I O N A L R E S O U R C E S British Automatic Fire Sprinkler Association: bafsa.org.uk National Fire Sprinkler Network: nfsn.co.uk European Fire Sprinkler Network: eurosprinkler.org
  • 7.
    F B CS Y S T E M C O M PAT IB L E A range of ancillary products are tested to ensure chemical compatibility with BlazeMaster® Pipe and Fittings, including thread sealants, construction materials and firestops. Visit FBCSystemCompatible.com for a full list of compatible products and proceed with confidence. T R A I N I N G & E D U C AT I O N To ensure proper installation, BlazeMaster® Fire Sprinker Systems offer comprehensive in-person and online training for installers, contractors, engineers and construction managers. Training covers cutting and joining, listings and approvals, chemical compatibility, best practices, health and safety and more. Those who successfully complete the course receive a BlazeMaster training card and certificate of completion. M A N U FA C T U R I N G N E T W O R K BlazeMaster® Fire Protection Systemspartners with the top pipeandfittings manufacturersacross the globe to ensure quality control and meet the most rigid specifications.
  • 8.
    DELIVERING RELIABILITY. F OR LIFE. Visit blazemaster.eu or call 00 44 (0)1332 842211 or email blazemaster.emena@lubrizol.com to contact a piping systems consultant. The information contained herein is reliable based on current information but the advertiser makes no representations, guarantees or warranties, express or implied, including any implied warranties of merchantability or fitness for a particular purpose, or regarding the completeness, accuracy, or timeliness of any information. Always consult your pipe and/or fitting manufacturer for current recommendations. ©The Lubrizol Corporation 2017, all rights reserved. All marks are property of The Lubrizol Corporation, a Berkshire Hathaway Company. 17-93972 Rev October 2017 - EU