Trading Green imports and distributes high-performance eco-friendly materials since 2008.
Main areas of expertise: insulation materials, wastewater treatment.
Acoustic Ultraline: High-Performance Noise Reduction, Natural Fiber, Durable,...Trading Green Ltd.
The ASTM-certified Acoustic Ultraline series of acoustic insulation panels is designed to offer the highest noise reduction in a Do-It-Yourself ready-to-install package.
Acoustic Ultraline panels are made of 100% natural reinforced fiber, which makes for an aesthetic finish and easy installation. No additional wrapping or lining is necessary.
Acoustic Ultraline will last for decades without degradation in looks or performance, making it suitable for all noise insulation purposes in homes, theatres, commercial buildings and industrial facilities. Panels also offer additional thermal insulation and energy-efficiency with a very low thermal conductivity of 0.037 W/mK.
Trading Green imports and distributes high-performance eco-friendly materials since 2008.
Main areas of expertise: insulation materials, wastewater treatment.
Acoustic Ultraline: High-Performance Noise Reduction, Natural Fiber, Durable,...Trading Green Ltd.
The ASTM-certified Acoustic Ultraline series of acoustic insulation panels is designed to offer the highest noise reduction in a Do-It-Yourself ready-to-install package.
Acoustic Ultraline panels are made of 100% natural reinforced fiber, which makes for an aesthetic finish and easy installation. No additional wrapping or lining is necessary.
Acoustic Ultraline will last for decades without degradation in looks or performance, making it suitable for all noise insulation purposes in homes, theatres, commercial buildings and industrial facilities. Panels also offer additional thermal insulation and energy-efficiency with a very low thermal conductivity of 0.037 W/mK.
Apollo Insulation Aluminum Composite Foils - Catalog 2012Trading Green Ltd.
Apollo Insulation foils reflect more than 96% of radiating heat, reduce carbon emissions and last for life.
They are used for building insulation, pipe and vent insulation and cladding, foam panel and sandwich panel insulation.
Feb.10: True Corp.'s Internet made cooler with Planet Supra Thermal Barrier P...Trading Green Ltd.
True Corp. reduced temperature load on Internet distribution boxes by up to 16% by painting with Planet Supra Thermal Barrier Paint. The electronic equipment's reliability and lifetime will be improved, while maintenance costs are expected to be reduced.
Carrefour reduces building heat load with Thermal Barrier PaintTrading Green Ltd.
In the process of evaluating the Thermal Barrier Paint's performance and energy-saving potential, Carrefour Thailand painted half of a warehouse's rooftop. Temperatures were recorded simultaneously on both sides, the result demonstrated a dramatic heat load drop on the side painted. 1.1 Ton of CO2 are offset per year for up to 10 years by this project.
7-Eleven store in PTT gas station reduces air-con cost with Planet SupraTrading Green Ltd.
Petroleum Authority of Thailand (PTT) manages gas stations with co-located 7-11 stores. Both buildings' heat load dropped sharply after painting rooftops with Planet Supra Thermal Barrier Paint. Substantial cost-savings on air-conditioning are expected. 0.4 Ton of Carbon Credits are offset by this pilot project, contributing to reduce PTT's carbon footprint.
Carrefour aims for green cost-savings with Thermal Barrier PaintTrading Green Ltd.
Global retailer Carrefour successfully tested Planet Supra Thermal Barrier Paint to reduce its buildings' heat load. Direct consequence expected is a sharp drop on the air-conditioning system's heat load, translating into energy savings and carbon footprint reduction.
Four Seasons Hotel improves boiler insulation and energy-efficiency with Plan...Trading Green Ltd.
The Four Seasons Hotel in Bangkok, Thailand, is always looking for new ways to save energy and improve its eco-friendliness. Planet Supra Thermal Barrier Paint was successfully tested in october to reduce energy consumption of its boilers and improve staff working conditions and safety at the same time. Boilers' and hot pipes' urface temperature is reduced by up to 10 degrees Celsius.
NeoBio stops pollution caused by island resort's wastewaterTrading Green Ltd.
Sept. 2009: An island resort under construction in Thailand was polluting the environment with wastewater coming from the worker camps' toilets. After using NeoBio for 2 months, the pollution and nuisances have stopped.
5,000 vehicle logistics fleet's trucks are upgraded by painting cargo compartment rooftops with Thermal Barrier Paint. Trucks now qualify as Temperature Controlled and will generate more revenue.
Major logistics group in Japan choses Thermal Barrier Paint to control temperature inside its warehouses. Goods safety is improved and client has can be expanded, employee work conditions improved.
Apollo Insulation Aluminum Composite Foils - Catalog 2012Trading Green Ltd.
Apollo Insulation foils reflect more than 96% of radiating heat, reduce carbon emissions and last for life.
They are used for building insulation, pipe and vent insulation and cladding, foam panel and sandwich panel insulation.
Feb.10: True Corp.'s Internet made cooler with Planet Supra Thermal Barrier P...Trading Green Ltd.
True Corp. reduced temperature load on Internet distribution boxes by up to 16% by painting with Planet Supra Thermal Barrier Paint. The electronic equipment's reliability and lifetime will be improved, while maintenance costs are expected to be reduced.
Carrefour reduces building heat load with Thermal Barrier PaintTrading Green Ltd.
In the process of evaluating the Thermal Barrier Paint's performance and energy-saving potential, Carrefour Thailand painted half of a warehouse's rooftop. Temperatures were recorded simultaneously on both sides, the result demonstrated a dramatic heat load drop on the side painted. 1.1 Ton of CO2 are offset per year for up to 10 years by this project.
7-Eleven store in PTT gas station reduces air-con cost with Planet SupraTrading Green Ltd.
Petroleum Authority of Thailand (PTT) manages gas stations with co-located 7-11 stores. Both buildings' heat load dropped sharply after painting rooftops with Planet Supra Thermal Barrier Paint. Substantial cost-savings on air-conditioning are expected. 0.4 Ton of Carbon Credits are offset by this pilot project, contributing to reduce PTT's carbon footprint.
Carrefour aims for green cost-savings with Thermal Barrier PaintTrading Green Ltd.
Global retailer Carrefour successfully tested Planet Supra Thermal Barrier Paint to reduce its buildings' heat load. Direct consequence expected is a sharp drop on the air-conditioning system's heat load, translating into energy savings and carbon footprint reduction.
Four Seasons Hotel improves boiler insulation and energy-efficiency with Plan...Trading Green Ltd.
The Four Seasons Hotel in Bangkok, Thailand, is always looking for new ways to save energy and improve its eco-friendliness. Planet Supra Thermal Barrier Paint was successfully tested in october to reduce energy consumption of its boilers and improve staff working conditions and safety at the same time. Boilers' and hot pipes' urface temperature is reduced by up to 10 degrees Celsius.
NeoBio stops pollution caused by island resort's wastewaterTrading Green Ltd.
Sept. 2009: An island resort under construction in Thailand was polluting the environment with wastewater coming from the worker camps' toilets. After using NeoBio for 2 months, the pollution and nuisances have stopped.
5,000 vehicle logistics fleet's trucks are upgraded by painting cargo compartment rooftops with Thermal Barrier Paint. Trucks now qualify as Temperature Controlled and will generate more revenue.
Major logistics group in Japan choses Thermal Barrier Paint to control temperature inside its warehouses. Goods safety is improved and client has can be expanded, employee work conditions improved.
Apollo Energy อลูมิเนียมฟอยล์ ฉนวนป้องกันความร้อนและเย็น
1. made
in UK ฉนวนกันความร้ อนและช่ วยลดปริมาณการปล่ อยก๊ าซคาร์ บอน
ECO-FOIL™ THERMO-FOIL ES™
ECO-BRITE™ ENCA-SEAL™
ENCA-CLAD™ INSUFLECT™
TERRETHENE™ เทปกาว
BS476
fire rated
w w w.t ra d i n g g r e e n l t d . c o m
2. in UK
made
ThermoFoil®ES /
Standard ThermoFoil® Tape Eco-Brite® Insuflect™ EncaSeal™ 150PE EncaSeal™ Tape EncaClad™ EcoFoil™ Terrethene™
Agriliner*
floor, ceiling, floor, ceiling, indoors: pipes, A/C ducts, pipes, outdoors: indoors ceiling,
Recommended usage roof, walls sandwich panels sub-surface
roof, wall roof, wall ducts, vents tanks pipes/ducts/vents walls
Reflectivity ASTM E903 96.7% 96.1% 96.1% 96.7% 96.1% 96.1% 96.1% 96.0%
Emissivity ASTM E408 0.046 0.048 0.048 0.048 0.048 0.048 0.048 0.05
Manufacturer guarantee (years) 20 20 20 20 20 20 20 10 20
Expected lifespan (years) 60+ 60+ 60+ 60+ 60+ 60+ 60+ 20+ 60+
Carbon Emissions Saved per SQM, per year up to 23kg up to 23kg up to 23kg up to 23kg up to 23kg up to 23kg up to 23kg up to 23kg
Roll size (widht x length) 1.25m x 96m 1.25m x 96m 100m x 5cm 1.25m x 96m 1.25m x 96m 1.25m x 96m 100m x 5cm 1.25m x 33m 1.25m x 96m 1.195m x 50m
Roll surface in SQM 120m2 120m2 5m2 120m2 120m2 120m2 5m2 41.25m2 120m2 60m2
Roll weight kg 18 1.1 18 20 20 1.1 20 18 24.8
Nominal thickness microns 145 145 135 230 150 150 345 91 460
ASTM D882
Tensile MD 6.620kN/m 3.905kN/m 3.905kN/m 6.000kN/m 6.620kN/m 6.620kN/m 5.900kN/m N/A 9.45kN/M
Tear resistant machine direction
Trouser tear MD 33.1N N/A 10.2N N/A N/A N/A N/A N/A
Elongation at break MD 222.60% N/A 232.80% N/A N/A N/A N/A N/A
ASTM D882
Tensile CD 5.487kN/m 4.096kN/m 4.096kN/m 5.000kN/m 5.000kN/m 5.000kN/m 4.900kN/m N/A
Tear resistant cross direction
Trouser tear CD 33.9N N/A 15.6N N/A N/A N/A N/A N/A
Elongation at break CD 210% 150% 100.40% N/A 150% 150% N/A N/A
Beach Puncture Resistance 40.1kg-cm 40.5kg-cm 40.5kg-cm 40.0kg-cm 40.5kg-cm 41.1kg-cm 40.0kg-cm
Moisture/vapour transmission rate ASTM E96, Procedure B, MVTR 0.021g/m3 0.045g/m3 0.045g/m3 0.021g/m3 0.021g/m3 0.021g/m3 0.020g/m3 <2g/ m²/24hrs 0.01g/m2/24h
Corrosion resistant Unique surface coating
UV resistant Tested for the equivalent of 30 years at 100% humidity & 100% UV Tested for 20 years
Fire Propagation BS476 Part 6 Class 0 Class 0 Class 0 Class 0 Class 0 Class 0 Class 0 N/A
Surface Flame Spread BS476 Part 7 Class 1 Class 1 Class 1 Class 1 Class 1 Class 1 Class 1 N/A
w w w.t ra d i n g g r e e n l t d . c o m
Temperature resistant -50°C to +127°C -50°C to +127°C -50°C to +127°C -37°C to +127°C -37°C to +127°C -37°C to +127°C -35°C to +127°C -35°C to +127°C -20°C to +80°C
Cross-Laminated Valeron® Core YES NO YES YES YES NO YES YES NO
Chemical resistant Approved concentrated disinfectants
Methane transmission <0.005cm3/h/m2
Oxygen transmission Nil
N/A
Radon improvement factor 500-1
CBR 708N
* ThermoFoil ES™ is also known as Agriliner™ in certain countries, for the livestock farms market.
ฉนวนกันความร้ อนและช่ วยลดปริมาณการปล่ อยก๊ าซคาร์ บอน
7. ThermoFoil®ES
อ ลู มิ เ นี ย ม ฟ อ ย ล์ ฉ น ว น ป อ ง กั น ค ว า ม ร้ อ น กั บ C r o s s - L a m i n a t e d V a l é r o n ® c o r e
้
ฉนวนกันความร้ อนและเย็นประสิทธิภาพสูง
มีความทนทานสูง
รั บประกัน 20 ปี อายุการใช้ งานมากกว่ า 60 ปี
พืนฐานเทคโนโลยีของ NASA
้
แกรนด์มสยิดอาบูดาบี
ั Raffles Hotel สิงคโปร์ โรงงาน Mattel ประเทศไทย
ปศุสตว์สหรัฐอเมริกาบ้ าน
ั กระทรวงการต่างประเทศอาบูดาบี อาคารสานักงานใหญ่ Sony ฉนวนกันความเย็นในสหราชอาณาจักร
สะท้ อนแสง 96.7%
ปล่อยมลภาวะเพียง 0.046 ปั กกิ่งโอลิมปิ ก 2008 ฉนวนกันความร้ อนหลังคาสหราชอาณาจักร
อัตราการส่งผ่านความชื ้น 0.021g/m 2
ลดการใช้ พลังงานภายในอาคาร
ลดการปล่อยก๊ าซคาร์ บอนออกสู่อากาศ
CARBON smart green
OFFSET product
8. ThermoFoil®ES
อ ลู มิ เ นี ย ม ฟ อ ย ล์ ฉ น ว น ป อ ง กั น ค ว า ม ร้ อ น กั บ C r o s s - L a m i n a t e d V a l é r o n ® c o r e
้
แนะนาการใช้ งาน หลังคาในประเทศโซนเขตร้ อน
Thermo-Foil®ES เป็ นอุปสรรคต่อความร้ อน: จะต้ องมีการติดตังหันหน้ าไปทางช่องว่างอากาศ
้
อย่างน้ อยหนึ่ง 19mm ถึง 25mm
เมื่อใช้ ร่วมกับโฟม PE foam, PU foam, ไฟเบอร์ กลาสหรือบนหลังคาสะท้ อนแสง Thermo-
Foil® ES สามารถปรับปรุง ค่า U - Value ของโครงสร้ างนันได้ ถึง 20% ในสภาพอากาศเขตร้ อน.
้
แนะนาการใช้ ห้ องเย็น
ข้ อแนะนาในการติดตัง้ ThermoFoil ® ES ในช่องของแผงฉนวนกันความร้ อนเพื่อที่จะทาการ
สะท้ อนความร้ อนที่อยูนอกกลับออกไปและกลับมาเย็นภายใน
่
ฟอยล์เป็ นสินค้ าที่ปองการการก่อคามเสียหายด้ วยพวกแมลงไม่ก่อให้ เกิดเชื ้อรา นอกจากนี ้ยังเป็ น
้
อุปสรรคต่อความชื ้นที่ดีเยี่ยมแลปกปองและปองกันจากพวกะฝุ่ นละออง เหมาะสาหรับโครงสร้ าง
้ ้
หรือบริษัทที่ต้องการความปลอดภัยสูง เช่นอุตสาหกรรมยา,ะอาหารและเครื่องดื่ม
สะท้ อนแสง (ASTM E903) 96.70%
การปล่ อยมลภาวะเป็ นพิษออกสู่อากาศ (ASTM E408) 0.046
การปล่ อยก๊ าซคาร์ บอนที่บันทึกไว้ 23kg on un-insulated wall, 12.33kg on insulated wall per sqm per annum
ขนาดโรล์ และนาหนัก
้ 96m x 1.25m 120m² 18 kg
ขนาดโรล์ และนาหนัก
้ 145 microns
ทนต่ อแรงฉีกขาด Machine Direction (MD) (ASTM D882) Tensile MD 6.620kN/m, Trouser tear MD 33.1N, Elongation at break MD 222.6%
ทนต่ อแรงฉีกขาด Cross Direction (CD) (ASTM D882) Tensile CD 5.487kN/m, Trouser tear CD 33.9N, Elongation at break CD 210%
ความต้ านทานต่ อ Beach Puncture (ASTM D774) 40.1kg-cm
ความชืน/ไอ อัตราการส่ งผ่ าน (ASTM E96, ขันตอน B,
้ ้
0.021g/m²
MVTR)
ทนต่ อการกัดกร่ อน เคลือบพิ ้นผิวลักษณะเฉพาะตัว
ทน ต่ อ UV การทดสอบให้ ผลเท่ากันกว่า 30 ปี ที่ความชื ้น 100% และปกปองรังสี UV 100%
้
BS476 ส่ วนที่ 6 Fire กาลุกลามของไฟ Class 0
BS476 ส่ วนที่ 7 การกระจายตัวของไฟต่ อพืนผิว
้ Class 1
ทนอุณหภูมิ -50°C to +127°C
Cross ลามิเนต Valéron® Core ใช่ : ปองกันไม่ให้ ชนอลูมิเนียมและปองกันการเสื่อมเสียจากการฉีกขาด
้ ั้ ้
ทนความดันล้ างสูง 207 bar at 300mm
ทนต่ อสารเคมี Tested with approved concentrated disinfectants.
ติดต่อฝ่ ายขาย
Trading Green (Thailand) Ltd.
สานักงาน: +66 (0) 2660 3601
Email: info@tradinggreenltd.com
นาเข้ าเพียงผู้เดียวโดยกรีนเทรดดิ ้ง จากัด , อาคาร Interchange 21, ชัน 32, 399 ถนนสุขมวิทแขวงคลองเตยเหนือเขตวัฒนากรุงเทพฯ 10110 ประเทศไทย
้ ุ
สานักงาน: +66 (0) 2660 3601 แฟกซ์ : +66 (0) 2660 3881 Email: info@tradinggreenltd.com Internet: www.tradinggreenltd.com