SlideShare a Scribd company logo
1 of 14
Download to read offline
D800032X012
May 2011
DeltaV SIS™
Process Safety System
Safety Manual
Printed in the Republic of Singapore.
© Emerson Process Management 1996 - 2011. All rights reserved. For Emerson Process Management trademarks and service
marks, go to http://www.emersonprocess.com/home/news/resources/marks.pdf. All other marks are property of their respective
owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to
ensure their accuracy, they are not to be construed as warranties or guarantees, expressed or implied, regarding the products or
services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on
request. We reserve the right to modify or improve the design or specification of such products at any time without notice.
Emerson Process Management
Distribution Ltd. Process Systems and
Solutions
Meridian East
Meridian Business Park
Leicester, LE19 1uX, UK
Emerson a.s.
European System and Assembly
Pieštanská 1202/44
Nové Mesto nad Váhom 91528
Slovakia
Fisher-Rosemount Systems, Inc. – an
Emerson Process Management company
12301 Research Blvd.
Research Park Plaza – Bldg. III
Austin, TX 78759
Contents iii
Contents
1 DeltaV SIS Process Safety System Safety Manual . . . . . . . . . . . . . . . . . . . . . . . . .1
2 Certification Coverage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
2.1 Certified Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2.2 SIL Applicability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2.2.1 De-energized to Trip Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.2.2 Response Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3 SIL Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4 Restrictions: SLS 1508 Specific . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5 Restrictions: All Logic Solver Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6 Special Features: SLS 1508 Specific . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
7 Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
7.1 Product Life. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
7.2 Environmental Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
7.3 Application Limits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
8 Recommendations for Management of Functional Competency. . . . . . . . . . . . . .7
9 Reporting Product Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
10 Other Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
10.1 Energized to Trip Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
10.1.1 Energized to Trip Applications (with Inverted Logic) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
10.1.2 Energized to Trip Applications (with Auxiliary Relay) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
10.2 High Demand Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
10.2.1 Response Time in High Demand Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
10.2.2 Other Considerations for High Demand Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
iv DeltaV SIS Process Safety System Safety Manual
DeltaV SIS Process Safety System Safety Manual 1
1 DeltaV SIS Process Safety System Safety
Manual
This document contains important information on how DeltaV SIS is to be used in a
safety instrumented system to place and/or maintain the equipment under control in
an appropriate state when expected to do so. The guidelines in this document should
be followed when using DeltaV SIS in safety-critical applications.
To determine whether this document is the most recent revision applicable to a
particular revision of the SLS 1508, compare the part number shown on the cover of
this document to the part number found on the SureService Guardian website:
https://guardian.emersonprocess.com
Log into the Guardian website and look for the DeltaV SIS links under Resources.
2 Certification Coverage
2.1 Certified Components
The information in this document applies to hardware and software components of
DeltaV SIS that have been certified according to IEC 61508. TUV has certified the
SLS 1508 hardware and firmware as suitable for use in safety applications with a
maximum Safety Integrity Level (SIL) of 3 (SIL3) according to IEC 61508 Part 1 to
Part 7. Refer to https://guardian.emersonprocess.com for a complete listing of the
certified SIL compliant and interference free hardware and software components of
DeltaV SIS.
2.2 SIL Applicability
The maximum Safety Integrity Level for the SLS 1508:
Refer to “Other Applications” on page 8 for SIL ratings and a discussion on energized
to trip applications.
Simplex Redundant
De-energized to
Trip application
SIL3 SIL3
2 DeltaV SIS Process Safety System Safety Manual
2.2.1 De-energized to Trip Applications
In de-energized to trip applications the advanced logic solver architecture of the SLS
1508 achieves SIL3 safety in a simplex hardware module. A simplex SLS 1508
provides the hardware fault tolerance and safe failure fraction to meet SIL3
architectural requirements. A redundant SLS 1508 meets SIL3 architectural
requirements, utilizing redundancy to increase availability and to reduce false trips.
The SIL3 rating applies to both the low and high demand modes of operation.
In a de-energized to trip application the safe state for all output channels of a given
safety instrumented function (SIF) is off/low. This corresponds to the safe state of
output channels if the SLS 1508 needs to remove power in response to a dangerous
failure being detected by its advanced diagnostics.
Refer to “Engineering Practices” in the DeltaV SIS Process Safety System Users Guide for
configuration guidelines for de-energized to trip applications.
When higher powered discrete outputs are needed, there are two standard product
options that utilize external relay modules as part of the logic solver subsystem. There
is a SIL3 option if line monitoring is not needed and a SIL2 option with line
monitoring. Refer to Installing Your DeltaV SIS Process Safety System Hardware for more
information. SIS module configuration techniques do not change when the auxiliary
relays are used in a de-energized to trip function.
2.2.2 Response Time
The response time for a SIF should be less than the process safety time. The SIF has
a response time associated with the sensor, logic solver, and final element subsystems.
The sum of the response times should be less than the process safety time. The
response time of the logic solver subsystem is the time between any change on a SIF
input channel that should result in a trip and the time that the output channel or
channels change to the tripped state. The time is measured from screw terminal to
screw terminal.
The response time is impacted by the configured scan rate of the SLS 1508 containing
the SIS module logic for the SIF. There is some variability due to the alignment of the
SIL Verification 3
change at the input screw terminal and I/O scanning in the SLS 1508. The following
table shows the maximum response times.
Note the following concerning response times for the logic solver subsystem.
1. The response time does not increase if an input channel of the SIF is on an SLS
1508 other than the SLS 1508 driving outputs.
2. If there are multiple SIS modules involved in the SIF with communication using
secure parameters, the maximum response time increases by the scan rate of the
SLS 1508 containing the secure parameter (not the secure parameter reference).
For example, two SIS modules at a 50 millisecond scan rate increases the
maximum response time from 175 to 225 milliseconds. If communication is
between DeltaV SIS nodes across the remote peer ring (SISNet), there is a
potential for the response time to increase by an additional 50 milliseconds.
3. If SIS module logic includes delays such as the trip delay time in voter function
blocks, the response time will increase by the length of those delays.
3 SIL Verification
In order to verify that a SIF meets the assigned SIL the probability of the SIF failing
dangerously is determined. The DeltaV SIS FMEDA Report contains failure rate and
other data to help you verify that your safety requirements are being met. It contains
the information necessary to do SIL verification calculations for the SIF’s logic solver
subsystem, including failure rates by failure category, diagnostic coverage and
common cause factors, hardware fault tolerance, and device type.
The use of a SIL verification tool is encouraged in order to get the most accurate
results possible. Emerson Process Management recommends the exida exSILentia
tool (SILVer), whose SIL verification uses Markov analysis and is based on data from
the DeltaV SIS FMEDA Report.
SLS 1508 scan rate
(milliseconds)
Maximum response
time
(milliseconds)
50 175
100 275
150 375
200 475
4 DeltaV SIS Process Safety System Safety Manual
The DeltaV SIS FMEDA Report is available at
https://guardian.emersonprocess.com.
4 Restrictions: SLS 1508 Specific
There are no SLS 1508 specific restrictions.
5 Restrictions: All Logic Solver Systems
As with all safety logic solvers, the SLS 1508 is to be used according to the practices
required by IEC 61508 and IEC 61511 as summarized below:
 As with any logic solver, any modification or change shall be subject to a safety
impact analysis to determine all software modules impacted and the necessary re-
verification activities. A full functional test of the logic solver configuration may
be needed before the logic solver provides the protection function in a running
process.
Your site acceptance procedures should address functional testing of the
applications running in logic solvers.
Note It is possible to assess what has changed in the SLS 1508 since the last functional test
by examining the CRC values in DeltaV Diagnostics Explorer.
 The SLS 1508 provides the ability to download configuration changes on-line.
When any safety instrumented function in any logic solver is disabled or
bypassed, safety should be provided by alternative means. If a logic solver allows
on-line changes, until those changes are verified via functional testing it is
assumed that the SIF(s) under change are disabled. For any disabled or bypassed
SIF:
1. The equipment under control should be supervised until completion of the
functional test (or the assessment of the need to test if a functional test is not
required).
2. The process safety time associated with the hazard should be long enough
for operators to monitor and react, and thus manually provide the protection
function during the bypass or download / functional test.
 A periodic proof test should be performed to reveal potentially dangerous faults
not detected by continuous runtime diagnostics in the logic solver. The necessary
frequency of the proof test is a function of the probability of dangerous failure
for the safety instrumented function(s) associated with the logic solver.
Special Features: SLS 1508 Specific 5
6 Special Features: SLS 1508 Specific
 The SLS 1508 provides a Non-Secure Parameter Reference feature. This is a user-
defined parameter type available in SIS modules for non safety-critical use. If a
parameter of this type contributes to a safety-critical control action, special
consideration is needed in SIS module logic to validate the parameter value. The
application programmer should not allow the safety function to be compromised
based on the value of a Non-Secure Parameter Reference. Refer to “Engineering
Practices” in the DeltaV SIS Process Safety System Users Guide for more information.
 Other than the Non-Secure Parameter Reference, all configuration elements
available in SIS modules may be used without special consideration in a safety-
critical application up to and including SIL3. This includes the Calculation-Logic
function block expression language, which is a limited variability language.
 The SLS 1508 automatically responds to faults common to all I/O channels, such
as malfunction of a processor or a memory failure, by de-energizing all output
channels. This leaves output devices under control of the partner when using
redundant SLS 1508s. A fault on an output channel will not prevent de-
energization in the case of a demand to trip on that channel. There is an
automatic, secondary means of de-energization when needed. For detail on fault
detection and how the SLS 1508 and DeltaV SIS respond to those faults, refer to
“Maintenance Practices” in the DeltaV SIS Process Safety System Users Guide.
 The person configuring SIS module logic has influence over the SLS 1508's
response to certain faults detected in the SLS 1508 and field instruments. For
faults specific to one I/O channel or one field device, the SLS 1508 integrates
Bad status with the value on the channel. The SIS module can be configured to
respond to Bad status as needed by the application. Configuring the system
response to Bad status is a matter of choosing status options, fault state options,
and certain time duration values as the application requires. Refer to “Engineering
Practices” in the DeltaV SIS Process Safety System Users Guide for more information
on configuring the system response to detected faults. The DeltaV SIS book in
DeltaV Books Online has detailed information on the features of the function
blocks available in SIS modules.
 SLS 1508 outputs configured as HART Two-state Output channels are intended
for certain final elements. You should physically connect a channel of this type to
only a Fisher Controls DVC6000 SIS (firmware revision 6 or later) or a digital
valve controller certified by Emerson Process Management as being equivalent.
6 DeltaV SIS Process Safety System Safety Manual
Refer to “Engineering Practices” in the DeltaV SIS Process Safety System Users Guide
for more information on using digital valve controllers with the SLS 1508.
 The DeltaV SIS secure write server is certified for use in safety rated applications
up to SIL3. Only the secure write server can make runtime changes to parameters
in the SLS 1508 made from DeltaV workstations, including maintenance
bypasses, operator resets, and all other parameters that are allowed to be changed
at runtime. The secure write capability is integrated with DeltaV Operate
dynamos and faceplates for the advanced SIS function blocks and in DeltaV
Control Studio Online/Debug for SIS modules.
Note It is not necessary to do a functional test after a secure write is done. You can be certain
that the parameter value in the SLS 1508 is the value confirmed.
 The secure write operation is in addition to DeltaV security. The user who is
logged in at the DeltaV workstation needs to have the software key to the lock
associated with the writable parameter and parameter field.
 DeltaV SIS has a built-in bypass facility for managing maintenance overrides. A
bypass allows a maintenance activity such as calibration, proof testing, or repair of
a transmitter or other sensor to take place without a concern for a spurious trip.
Bypasses in SIS module logic in the SLS 1508 can be set and cleared from DeltaV
workstations using a secure write operation. Refer to “Operations Practices” in
the DeltaV SIS Process Safety System Users Guide for additional information on the
DeltaV SIS bypass facility.
 A proof test of the SLS 1508 is conducted by forcing the logic solver to go
through reset and power-up testing. This is initiated by using a context menu
command from DeltaV Diagnostics Explorer and has no adverse impact to a
running process when redundant SLS 1508s are used. An automatic proof test is
optional for redundant SLS 1508s based on a configured proof test interval. Refer
to “Maintenance Practices” in the DeltaV SIS Process Safety System Users Guide for
more information on proof testing and additional topics on recommended
operations and maintenance practices for DeltaV SIS.
7 Limits
7.1 Product Life
The useful lifetime of the critical components of the SLS 1508 is 20 years.
Recommendations for Management of Functional Competency 7
7.2 Environmental Conditions
Refer to Installing Your DeltaV SIS Process Safety System Hardware for limits on
environmental conditions.
7.3 Application Limits
DeltaV engineering tools ensure that application limits are not exceeded. There are no
requirements to consider to prevent limits from being exceeded. Refer to “System
Capacities” in the Configuration book in DeltaV Books Online for the SIS application
limits.
8 Recommendations for Management of
Functional Competency
DeltaV SIS is intended to be used in accordance with a defined safety life cycle such as
that described in IEC 61511. IEC 61511 requires that persons, departments or
organizations involved in safety life-cycle activities shall be competent to carry out the
activities for which they are accountable. Emerson Process Management strongly
recommends that the following be considered when developing a competency
management program in order for DeltaV SIS users to achieve IEC 61511
compliance.
Competence of Persons - Engineering
All persons involved in the initial implementation or modification of the application
software should have appropriate training. Opportunities for training include reading
the DeltaV SIS Process Safety System Safety Manual, the DeltaV SIS Process Safety System
Users Guide, DeltaV Books Online, and attending a training class lead by Emerson
Process Management certified personnel. Formal training is available through
Emerson Process Management Educational Services. For information, visit:
http://www.emersonprocess.com/education/contacts_centers.asp
Competence of Persons - Installation and Hardware Maintenance
All persons involved in installation and hardware maintenance activities should have
appropriate training. Opportunities for training include reading the DeltaV SIS Process
Safety System Users Guide, Installing Your DeltaV SIS Process Safety System Hardware, reading
DeltaV Books Online, and attending a training class lead by Emerson Process
Management certified personnel. Formal training is available through Emerson
Process Management Educational Services.
8 DeltaV SIS Process Safety System Safety Manual
Competence of Persons - General
All persons involved in any aspect of DeltaV SIS, including engineers, operators,
supervisors, maintenance personnel, and system administrators, should have training
in the importance of safety instrumented systems. All persons should have specific
training in the procedures for which they are responsible. DeltaV system
administrators should ensure that all individuals having security keys for DeltaV SIS
activities are trained and competent.
For technical support contact information and for reporting product issues, visit:
http://www.emersonprocess.com/systems/support/ratecard.htm
9 Reporting Product Issues
Refer to “Maintenance Practices” in the DeltaV SIS Process Safety System Users Guide for
more information on reporting product issues.
10 Other Applications
10.1 Energized to Trip Applications
The maximum Safety Integrity Levels for the SLS 1508 in energized to trip
applications are as follows:
10.1.1 Energized to Trip Applications (with Inverted Logic)
When the safe state for an SLS 1508 output channel is on/high, the application is
energized to trip from the perspective of the output channel. Energized to trip output
channels require SIS module configuration to drive the SLS 1508 output channel
value on/high to achieve the safe state. The SIS module logic essentially inverts the
output signals as compared to de-energized to trip logic.
Simplex Redundant
With inverted logic
Low demand mode SIL3 SIL3
High demand mode ___ SIL1
With auxiliary relay SIL2 SIL2
Other Applications 9
If the SLS 1508 removes power in response to detecting a dangerous failure in an
application with inverted SIS module logic, the equipment under control remains in
the normal operating state. The DeltaV system annunciates a dangerous failure in a
SLS 1508 by means of a hardware alarm. In response to the alarm operators can
manually take the process to the safe state if the repair cannot be completed within the
mean time to repair (MTTR) used for SIL verification.
Refer to “Engineering Practices” in the DeltaV SIS Process Safety System Users Guide for
configuration guidelines for energized to trip applications using inverted logic. Refer
to “Maintenance Practices” in the DeltaV SIS Process Safety System Users Guide for more
information on DeltaV SIS fault annunciation.
10.1.1.1 Using Inverted Logic in Low Demand Mode
In the low demand mode of operation there is ample time to manually respond to an
annunciated dangerous failure. Credit can be taken for SLS 1508 diagnostics such that
dangerous detected failures are included in the safe failure fraction. The SLS 1508
meets SIL 3 architectural requirements as simplex or redundant.
10.1.1.2 Using Inverted Logic in High Demand Mode
In the high demand mode the process safety time or demand rate may not allow time
for a manual response following the annunciation of a dangerous failure. Emerson
Process Management recommends that no credit be taken for diagnostics when using
inverted logic in high demand mode.
A redundant hardware configuration is required for safety rated applications. In a
redundant configuration either of the two hardware modules is able to drive the
output channel on/high, providing the hardware fault tolerance and safe failure
fraction to meet SIL 1 architectural requirements. The amount of time operating
without an available partner SLS 1508 should be limited to the MTTR used in SIL
verification.
10.1.2 Energized to Trip Applications (with Auxiliary Relay)
If a higher powered discrete output is needed for an energized to trip application, an
Auxiliary Relay DTA-Inverting and Auxiliary Relay Diode module can be combined
with the SLS 1508. In this case the inverting of the output signal is done through
external hardware. The SIS module is configured to drive the outputs off/low to
achieve the safe state, the same as in a de-energized to trip application. The logic
solver subsystem meets a SIL2 architectural requirement with a simplex or redundant
SLS 1508 in both low and high demand modes. Refer to Installing Your DeltaV SIS
Process Safety System Hardware for more information.
10 DeltaV SIS Process Safety System Safety Manual
Refer to “Engineering Practices” in the DeltaV SIS Process Safety System Users Guide for
configuration guidelines for energized to trip applications using the auxiliary relay
modules.
10.2 High Demand Mode
10.2.1 Response Time in High Demand Mode
The response time discussion for low demand mode on page 2 also applies when
operating in high demand mode.
Although the probability of an undetected fault being present at the time of a demand
is extremely low, you should assume a fault may be present when allocating the
response time for the logic solver subsystem in high demand mode applications. The
maximum fault detection plus reaction time of the SLS 1508 for any scan rate is 400
milliseconds. Therefore, for high demand mode applications, you should allocate an
additional 400 milliseconds for the logic solver subsystem response time, for example,
575 milliseconds for an SLS 1508 whose scan rate is 50 milliseconds. Note that the
recommendation to include the fault detection plus reaction time in the response time
does not apply in the low demand mode.
10.2.2 Other Considerations for High Demand Mode
The high demand mode of operation is defined by IEC 61508. High demand mode
may apply by definition or whenever it is more appropriate to treat a SIF as operating
in high demand mode instead of low demand. The following applies to both de-
energized to trip and energized to trip applications.
The SLS 1508 does not automatically de-energize outputs when faults are detected on
input channels because the fault may originate in field devices or field wiring. Instead,
the SLS 1508 integrates Bad status with the channel value. SIS module logic can be
configured to respond appropriately to Bad status on input channels. In high demand
mode applications the allowed repair time for faults detected on input channels
should be limited by SIS module configuration so that the SLS 1508 will drive
applicable outputs to the safe state if the repair cannot be completed in time.
Refer to “Engineering Practices” in the DeltaV SIS Process Safety System Users Guide for
more information on configuring the system response to detected faults.

More Related Content

What's hot

Sistema de combustível PDE e S6 Motor scania
Sistema de combustível PDE e S6 Motor scaniaSistema de combustível PDE e S6 Motor scania
Sistema de combustível PDE e S6 Motor scaniaLuiz Antonio da Silva
 
Cdvr service manual renr7941-00 _ sis - caterpillar
Cdvr   service manual   renr7941-00 _ sis - caterpillarCdvr   service manual   renr7941-00 _ sis - caterpillar
Cdvr service manual renr7941-00 _ sis - caterpillarOtorongosabroso
 
Transformer oil purification plant globecore CMM(UVM) 4-7
Transformer oil purification plant globecore CMM(UVM) 4-7Transformer oil purification plant globecore CMM(UVM) 4-7
Transformer oil purification plant globecore CMM(UVM) 4-7GlobeCore
 
Mercedes Benz- eletricidade-veicular-completo-04-11-04
Mercedes Benz- eletricidade-veicular-completo-04-11-04Mercedes Benz- eletricidade-veicular-completo-04-11-04
Mercedes Benz- eletricidade-veicular-completo-04-11-04Jose Roberto
 
381743680-CAT-Codigos-de-Falha-Atual.pdf
381743680-CAT-Codigos-de-Falha-Atual.pdf381743680-CAT-Codigos-de-Falha-Atual.pdf
381743680-CAT-Codigos-de-Falha-Atual.pdfEguima Guima
 
11 a motor 4g6
11 a motor 4g611 a motor 4g6
11 a motor 4g6dpazos
 
Basic Control Valve Sizing and Selection
Basic Control Valve Sizing and SelectionBasic Control Valve Sizing and Selection
Basic Control Valve Sizing and SelectionISA Boston Section
 
Volvo+engine+d12 c+&+d12d+informacion+de+servicio+especificaciones+edicion 8
Volvo+engine+d12 c+&+d12d+informacion+de+servicio+especificaciones+edicion 8Volvo+engine+d12 c+&+d12d+informacion+de+servicio+especificaciones+edicion 8
Volvo+engine+d12 c+&+d12d+informacion+de+servicio+especificaciones+edicion 8VanessaPrimoMaia
 
Introduction to Functional Safety and SIL Certification
Introduction to Functional Safety and SIL CertificationIntroduction to Functional Safety and SIL Certification
Introduction to Functional Safety and SIL CertificationISA Boston Section
 
Testing of Safety Valves
Testing of Safety ValvesTesting of Safety Valves
Testing of Safety ValvesCarl Stevens
 
Pressure Safety Valve Sizing - API 520/521/526
Pressure Safety Valve Sizing - API 520/521/526Pressure Safety Valve Sizing - API 520/521/526
Pressure Safety Valve Sizing - API 520/521/526Vijay Sarathy
 

What's hot (20)

Aga table
Aga tableAga table
Aga table
 
Sistema de combustível PDE e S6 Motor scania
Sistema de combustível PDE e S6 Motor scaniaSistema de combustível PDE e S6 Motor scania
Sistema de combustível PDE e S6 Motor scania
 
Cdvr service manual renr7941-00 _ sis - caterpillar
Cdvr   service manual   renr7941-00 _ sis - caterpillarCdvr   service manual   renr7941-00 _ sis - caterpillar
Cdvr service manual renr7941-00 _ sis - caterpillar
 
Pressure Relief Devices
Pressure Relief DevicesPressure Relief Devices
Pressure Relief Devices
 
Sistema electrico 950 h
Sistema electrico 950 hSistema electrico 950 h
Sistema electrico 950 h
 
Sil presentation
Sil presentationSil presentation
Sil presentation
 
Transformer oil purification plant globecore CMM(UVM) 4-7
Transformer oil purification plant globecore CMM(UVM) 4-7Transformer oil purification plant globecore CMM(UVM) 4-7
Transformer oil purification plant globecore CMM(UVM) 4-7
 
Manual de sintomas e falhas
Manual de sintomas e falhasManual de sintomas e falhas
Manual de sintomas e falhas
 
Maxxforce Euro v Agrale
Maxxforce Euro v Agrale Maxxforce Euro v Agrale
Maxxforce Euro v Agrale
 
Mercedes Benz- eletricidade-veicular-completo-04-11-04
Mercedes Benz- eletricidade-veicular-completo-04-11-04Mercedes Benz- eletricidade-veicular-completo-04-11-04
Mercedes Benz- eletricidade-veicular-completo-04-11-04
 
381743680-CAT-Codigos-de-Falha-Atual.pdf
381743680-CAT-Codigos-de-Falha-Atual.pdf381743680-CAT-Codigos-de-Falha-Atual.pdf
381743680-CAT-Codigos-de-Falha-Atual.pdf
 
11 a motor 4g6
11 a motor 4g611 a motor 4g6
11 a motor 4g6
 
Basic Control Valve Sizing and Selection
Basic Control Valve Sizing and SelectionBasic Control Valve Sizing and Selection
Basic Control Valve Sizing and Selection
 
Manual de diagnosticoacteon
Manual de diagnosticoacteonManual de diagnosticoacteon
Manual de diagnosticoacteon
 
Volvo+engine+d12 c+&+d12d+informacion+de+servicio+especificaciones+edicion 8
Volvo+engine+d12 c+&+d12d+informacion+de+servicio+especificaciones+edicion 8Volvo+engine+d12 c+&+d12d+informacion+de+servicio+especificaciones+edicion 8
Volvo+engine+d12 c+&+d12d+informacion+de+servicio+especificaciones+edicion 8
 
Introduction to Functional Safety and SIL Certification
Introduction to Functional Safety and SIL CertificationIntroduction to Functional Safety and SIL Certification
Introduction to Functional Safety and SIL Certification
 
Testing of Safety Valves
Testing of Safety ValvesTesting of Safety Valves
Testing of Safety Valves
 
SIL.ppt
SIL.pptSIL.ppt
SIL.ppt
 
Safety valves
Safety valvesSafety valves
Safety valves
 
Pressure Safety Valve Sizing - API 520/521/526
Pressure Safety Valve Sizing - API 520/521/526Pressure Safety Valve Sizing - API 520/521/526
Pressure Safety Valve Sizing - API 520/521/526
 

Similar to Delta v sis safety manual, may 2011

Siemens s7 300-400-testing your s7 programs with s7 plcsim
Siemens s7 300-400-testing your s7 programs with s7 plcsimSiemens s7 300-400-testing your s7 programs with s7 plcsim
Siemens s7 300-400-testing your s7 programs with s7 plcsimDien Ha The
 
Truyen thong
Truyen thongTruyen thong
Truyen thongTan Ngoc
 
Honeywell 7847i-install-guide
Honeywell 7847i-install-guideHoneywell 7847i-install-guide
Honeywell 7847i-install-guideAlarm Grid
 
Instruction Guide _ DeviceNet and RSNetWorx Configuration and Troubleshooting...
Instruction Guide _ DeviceNet and RSNetWorx Configuration and Troubleshooting...Instruction Guide _ DeviceNet and RSNetWorx Configuration and Troubleshooting...
Instruction Guide _ DeviceNet and RSNetWorx Configuration and Troubleshooting...Marco Enrique Ramos Castillo
 
Motorola solutions wing 4.4 ap7131 n access point product reference guide (pa...
Motorola solutions wing 4.4 ap7131 n access point product reference guide (pa...Motorola solutions wing 4.4 ap7131 n access point product reference guide (pa...
Motorola solutions wing 4.4 ap7131 n access point product reference guide (pa...Advantec Distribution
 
Motorola solutions wing 4.4 ap7131 n access point product reference guide (pa...
Motorola solutions wing 4.4 ap7131 n access point product reference guide (pa...Motorola solutions wing 4.4 ap7131 n access point product reference guide (pa...
Motorola solutions wing 4.4 ap7131 n access point product reference guide (pa...Advantec Distribution
 
Siemens catalog hmi-tp070 touch panel
Siemens catalog hmi-tp070 touch panelSiemens catalog hmi-tp070 touch panel
Siemens catalog hmi-tp070 touch panelDien Ha The
 
Siemens catalog hmi-tp070_e
Siemens catalog hmi-tp070_eSiemens catalog hmi-tp070_e
Siemens catalog hmi-tp070_eDien Ha The
 
V mware service-def-private-cloud-11q1-white-paper
V mware service-def-private-cloud-11q1-white-paperV mware service-def-private-cloud-11q1-white-paper
V mware service-def-private-cloud-11q1-white-paperChiến Nguyễn
 
Motorola solutions wing 4.4 ap51xx access point product reference guide (part...
Motorola solutions wing 4.4 ap51xx access point product reference guide (part...Motorola solutions wing 4.4 ap51xx access point product reference guide (part...
Motorola solutions wing 4.4 ap51xx access point product reference guide (part...Advantec Distribution
 
Essential Guide Cabeling System 2010
Essential Guide Cabeling System 2010Essential Guide Cabeling System 2010
Essential Guide Cabeling System 2010Gilbert Brault
 
Omron PLC cqm1 opearation manual
Omron PLC cqm1 opearation manualOmron PLC cqm1 opearation manual
Omron PLC cqm1 opearation manualYan Zhang
 
136280714-LTE100-Motorola-LTE-Training.pdf
136280714-LTE100-Motorola-LTE-Training.pdf136280714-LTE100-Motorola-LTE-Training.pdf
136280714-LTE100-Motorola-LTE-Training.pdfMohamedShabana37
 

Similar to Delta v sis safety manual, may 2011 (20)

Tdoct0713a eng
Tdoct0713a engTdoct0713a eng
Tdoct0713a eng
 
172809159 sip
172809159 sip172809159 sip
172809159 sip
 
Csdap
CsdapCsdap
Csdap
 
Siemens s7 300-400-testing your s7 programs with s7 plcsim
Siemens s7 300-400-testing your s7 programs with s7 plcsimSiemens s7 300-400-testing your s7 programs with s7 plcsim
Siemens s7 300-400-testing your s7 programs with s7 plcsim
 
430ug slau049f
430ug slau049f430ug slau049f
430ug slau049f
 
Truyen thong
Truyen thongTruyen thong
Truyen thong
 
Omron CS1D
Omron CS1DOmron CS1D
Omron CS1D
 
Honeywell 7847i-install-guide
Honeywell 7847i-install-guideHoneywell 7847i-install-guide
Honeywell 7847i-install-guide
 
Instruction Guide _ DeviceNet and RSNetWorx Configuration and Troubleshooting...
Instruction Guide _ DeviceNet and RSNetWorx Configuration and Troubleshooting...Instruction Guide _ DeviceNet and RSNetWorx Configuration and Troubleshooting...
Instruction Guide _ DeviceNet and RSNetWorx Configuration and Troubleshooting...
 
Motorola solutions wing 4.4 ap7131 n access point product reference guide (pa...
Motorola solutions wing 4.4 ap7131 n access point product reference guide (pa...Motorola solutions wing 4.4 ap7131 n access point product reference guide (pa...
Motorola solutions wing 4.4 ap7131 n access point product reference guide (pa...
 
Motorola solutions wing 4.4 ap7131 n access point product reference guide (pa...
Motorola solutions wing 4.4 ap7131 n access point product reference guide (pa...Motorola solutions wing 4.4 ap7131 n access point product reference guide (pa...
Motorola solutions wing 4.4 ap7131 n access point product reference guide (pa...
 
Siemens catalog hmi-tp070 touch panel
Siemens catalog hmi-tp070 touch panelSiemens catalog hmi-tp070 touch panel
Siemens catalog hmi-tp070 touch panel
 
Siemens catalog hmi-tp070_e
Siemens catalog hmi-tp070_eSiemens catalog hmi-tp070_e
Siemens catalog hmi-tp070_e
 
V mware service-def-private-cloud-11q1-white-paper
V mware service-def-private-cloud-11q1-white-paperV mware service-def-private-cloud-11q1-white-paper
V mware service-def-private-cloud-11q1-white-paper
 
802801 gbm
802801 gbm802801 gbm
802801 gbm
 
ISCO-3700-Manual.pdf
ISCO-3700-Manual.pdfISCO-3700-Manual.pdf
ISCO-3700-Manual.pdf
 
Motorola solutions wing 4.4 ap51xx access point product reference guide (part...
Motorola solutions wing 4.4 ap51xx access point product reference guide (part...Motorola solutions wing 4.4 ap51xx access point product reference guide (part...
Motorola solutions wing 4.4 ap51xx access point product reference guide (part...
 
Essential Guide Cabeling System 2010
Essential Guide Cabeling System 2010Essential Guide Cabeling System 2010
Essential Guide Cabeling System 2010
 
Omron PLC cqm1 opearation manual
Omron PLC cqm1 opearation manualOmron PLC cqm1 opearation manual
Omron PLC cqm1 opearation manual
 
136280714-LTE100-Motorola-LTE-Training.pdf
136280714-LTE100-Motorola-LTE-Training.pdf136280714-LTE100-Motorola-LTE-Training.pdf
136280714-LTE100-Motorola-LTE-Training.pdf
 

Recently uploaded

办理(UofR毕业证书)罗切斯特大学毕业证成绩单原版一比一
办理(UofR毕业证书)罗切斯特大学毕业证成绩单原版一比一办理(UofR毕业证书)罗切斯特大学毕业证成绩单原版一比一
办理(UofR毕业证书)罗切斯特大学毕业证成绩单原版一比一z xss
 
VIP Kolkata Call Girl Salt Lake 👉 8250192130 Available With Room
VIP Kolkata Call Girl Salt Lake 👉 8250192130  Available With RoomVIP Kolkata Call Girl Salt Lake 👉 8250192130  Available With Room
VIP Kolkata Call Girl Salt Lake 👉 8250192130 Available With Roomishabajaj13
 
Packaging the Monolith - PHP Tek 2024 (Breaking it down one bite at a time)
Packaging the Monolith - PHP Tek 2024 (Breaking it down one bite at a time)Packaging the Monolith - PHP Tek 2024 (Breaking it down one bite at a time)
Packaging the Monolith - PHP Tek 2024 (Breaking it down one bite at a time)Dana Luther
 
定制(CC毕业证书)美国美国社区大学毕业证成绩单原版一比一
定制(CC毕业证书)美国美国社区大学毕业证成绩单原版一比一定制(CC毕业证书)美国美国社区大学毕业证成绩单原版一比一
定制(CC毕业证书)美国美国社区大学毕业证成绩单原版一比一3sw2qly1
 
办理多伦多大学毕业证成绩单|购买加拿大UTSG文凭证书
办理多伦多大学毕业证成绩单|购买加拿大UTSG文凭证书办理多伦多大学毕业证成绩单|购买加拿大UTSG文凭证书
办理多伦多大学毕业证成绩单|购买加拿大UTSG文凭证书zdzoqco
 
Complet Documnetation for Smart Assistant Application for Disabled Person
Complet Documnetation   for Smart Assistant Application for Disabled PersonComplet Documnetation   for Smart Assistant Application for Disabled Person
Complet Documnetation for Smart Assistant Application for Disabled Personfurqan222004
 
A Good Girl's Guide to Murder (A Good Girl's Guide to Murder, #1)
A Good Girl's Guide to Murder (A Good Girl's Guide to Murder, #1)A Good Girl's Guide to Murder (A Good Girl's Guide to Murder, #1)
A Good Girl's Guide to Murder (A Good Girl's Guide to Murder, #1)Christopher H Felton
 
Git and Github workshop GDSC MLRITM
Git and Github  workshop GDSC MLRITMGit and Github  workshop GDSC MLRITM
Git and Github workshop GDSC MLRITMgdsc13
 
Call Girls South Delhi Delhi reach out to us at ☎ 9711199012
Call Girls South Delhi Delhi reach out to us at ☎ 9711199012Call Girls South Delhi Delhi reach out to us at ☎ 9711199012
Call Girls South Delhi Delhi reach out to us at ☎ 9711199012rehmti665
 
定制(UAL学位证)英国伦敦艺术大学毕业证成绩单原版一比一
定制(UAL学位证)英国伦敦艺术大学毕业证成绩单原版一比一定制(UAL学位证)英国伦敦艺术大学毕业证成绩单原版一比一
定制(UAL学位证)英国伦敦艺术大学毕业证成绩单原版一比一Fs
 
Font Performance - NYC WebPerf Meetup April '24
Font Performance - NYC WebPerf Meetup April '24Font Performance - NYC WebPerf Meetup April '24
Font Performance - NYC WebPerf Meetup April '24Paul Calvano
 
定制(AUT毕业证书)新西兰奥克兰理工大学毕业证成绩单原版一比一
定制(AUT毕业证书)新西兰奥克兰理工大学毕业证成绩单原版一比一定制(AUT毕业证书)新西兰奥克兰理工大学毕业证成绩单原版一比一
定制(AUT毕业证书)新西兰奥克兰理工大学毕业证成绩单原版一比一Fs
 
Call Girls Service Adil Nagar 7001305949 Need escorts Service Pooja Vip
Call Girls Service Adil Nagar 7001305949 Need escorts Service Pooja VipCall Girls Service Adil Nagar 7001305949 Need escorts Service Pooja Vip
Call Girls Service Adil Nagar 7001305949 Need escorts Service Pooja VipCall Girls Lucknow
 
Potsdam FH学位证,波茨坦应用技术大学毕业证书1:1制作
Potsdam FH学位证,波茨坦应用技术大学毕业证书1:1制作Potsdam FH学位证,波茨坦应用技术大学毕业证书1:1制作
Potsdam FH学位证,波茨坦应用技术大学毕业证书1:1制作ys8omjxb
 
Call Girls in Uttam Nagar Delhi 💯Call Us 🔝8264348440🔝
Call Girls in Uttam Nagar Delhi 💯Call Us 🔝8264348440🔝Call Girls in Uttam Nagar Delhi 💯Call Us 🔝8264348440🔝
Call Girls in Uttam Nagar Delhi 💯Call Us 🔝8264348440🔝soniya singh
 
Chennai Call Girls Alwarpet Phone 🍆 8250192130 👅 celebrity escorts service
Chennai Call Girls Alwarpet Phone 🍆 8250192130 👅 celebrity escorts serviceChennai Call Girls Alwarpet Phone 🍆 8250192130 👅 celebrity escorts service
Chennai Call Girls Alwarpet Phone 🍆 8250192130 👅 celebrity escorts servicevipmodelshub1
 
定制(Lincoln毕业证书)新西兰林肯大学毕业证成绩单原版一比一
定制(Lincoln毕业证书)新西兰林肯大学毕业证成绩单原版一比一定制(Lincoln毕业证书)新西兰林肯大学毕业证成绩单原版一比一
定制(Lincoln毕业证书)新西兰林肯大学毕业证成绩单原版一比一Fs
 
Call Girls In The Ocean Pearl Retreat Hotel New Delhi 9873777170
Call Girls In The Ocean Pearl Retreat Hotel New Delhi 9873777170Call Girls In The Ocean Pearl Retreat Hotel New Delhi 9873777170
Call Girls In The Ocean Pearl Retreat Hotel New Delhi 9873777170Sonam Pathan
 

Recently uploaded (20)

办理(UofR毕业证书)罗切斯特大学毕业证成绩单原版一比一
办理(UofR毕业证书)罗切斯特大学毕业证成绩单原版一比一办理(UofR毕业证书)罗切斯特大学毕业证成绩单原版一比一
办理(UofR毕业证书)罗切斯特大学毕业证成绩单原版一比一
 
VIP Kolkata Call Girl Salt Lake 👉 8250192130 Available With Room
VIP Kolkata Call Girl Salt Lake 👉 8250192130  Available With RoomVIP Kolkata Call Girl Salt Lake 👉 8250192130  Available With Room
VIP Kolkata Call Girl Salt Lake 👉 8250192130 Available With Room
 
Packaging the Monolith - PHP Tek 2024 (Breaking it down one bite at a time)
Packaging the Monolith - PHP Tek 2024 (Breaking it down one bite at a time)Packaging the Monolith - PHP Tek 2024 (Breaking it down one bite at a time)
Packaging the Monolith - PHP Tek 2024 (Breaking it down one bite at a time)
 
定制(CC毕业证书)美国美国社区大学毕业证成绩单原版一比一
定制(CC毕业证书)美国美国社区大学毕业证成绩单原版一比一定制(CC毕业证书)美国美国社区大学毕业证成绩单原版一比一
定制(CC毕业证书)美国美国社区大学毕业证成绩单原版一比一
 
办理多伦多大学毕业证成绩单|购买加拿大UTSG文凭证书
办理多伦多大学毕业证成绩单|购买加拿大UTSG文凭证书办理多伦多大学毕业证成绩单|购买加拿大UTSG文凭证书
办理多伦多大学毕业证成绩单|购买加拿大UTSG文凭证书
 
Complet Documnetation for Smart Assistant Application for Disabled Person
Complet Documnetation   for Smart Assistant Application for Disabled PersonComplet Documnetation   for Smart Assistant Application for Disabled Person
Complet Documnetation for Smart Assistant Application for Disabled Person
 
A Good Girl's Guide to Murder (A Good Girl's Guide to Murder, #1)
A Good Girl's Guide to Murder (A Good Girl's Guide to Murder, #1)A Good Girl's Guide to Murder (A Good Girl's Guide to Murder, #1)
A Good Girl's Guide to Murder (A Good Girl's Guide to Murder, #1)
 
Hot Sexy call girls in Rk Puram 🔝 9953056974 🔝 Delhi escort Service
Hot Sexy call girls in  Rk Puram 🔝 9953056974 🔝 Delhi escort ServiceHot Sexy call girls in  Rk Puram 🔝 9953056974 🔝 Delhi escort Service
Hot Sexy call girls in Rk Puram 🔝 9953056974 🔝 Delhi escort Service
 
Git and Github workshop GDSC MLRITM
Git and Github  workshop GDSC MLRITMGit and Github  workshop GDSC MLRITM
Git and Github workshop GDSC MLRITM
 
Call Girls South Delhi Delhi reach out to us at ☎ 9711199012
Call Girls South Delhi Delhi reach out to us at ☎ 9711199012Call Girls South Delhi Delhi reach out to us at ☎ 9711199012
Call Girls South Delhi Delhi reach out to us at ☎ 9711199012
 
定制(UAL学位证)英国伦敦艺术大学毕业证成绩单原版一比一
定制(UAL学位证)英国伦敦艺术大学毕业证成绩单原版一比一定制(UAL学位证)英国伦敦艺术大学毕业证成绩单原版一比一
定制(UAL学位证)英国伦敦艺术大学毕业证成绩单原版一比一
 
Font Performance - NYC WebPerf Meetup April '24
Font Performance - NYC WebPerf Meetup April '24Font Performance - NYC WebPerf Meetup April '24
Font Performance - NYC WebPerf Meetup April '24
 
定制(AUT毕业证书)新西兰奥克兰理工大学毕业证成绩单原版一比一
定制(AUT毕业证书)新西兰奥克兰理工大学毕业证成绩单原版一比一定制(AUT毕业证书)新西兰奥克兰理工大学毕业证成绩单原版一比一
定制(AUT毕业证书)新西兰奥克兰理工大学毕业证成绩单原版一比一
 
Model Call Girl in Jamuna Vihar Delhi reach out to us at 🔝9953056974🔝
Model Call Girl in  Jamuna Vihar Delhi reach out to us at 🔝9953056974🔝Model Call Girl in  Jamuna Vihar Delhi reach out to us at 🔝9953056974🔝
Model Call Girl in Jamuna Vihar Delhi reach out to us at 🔝9953056974🔝
 
Call Girls Service Adil Nagar 7001305949 Need escorts Service Pooja Vip
Call Girls Service Adil Nagar 7001305949 Need escorts Service Pooja VipCall Girls Service Adil Nagar 7001305949 Need escorts Service Pooja Vip
Call Girls Service Adil Nagar 7001305949 Need escorts Service Pooja Vip
 
Potsdam FH学位证,波茨坦应用技术大学毕业证书1:1制作
Potsdam FH学位证,波茨坦应用技术大学毕业证书1:1制作Potsdam FH学位证,波茨坦应用技术大学毕业证书1:1制作
Potsdam FH学位证,波茨坦应用技术大学毕业证书1:1制作
 
Call Girls in Uttam Nagar Delhi 💯Call Us 🔝8264348440🔝
Call Girls in Uttam Nagar Delhi 💯Call Us 🔝8264348440🔝Call Girls in Uttam Nagar Delhi 💯Call Us 🔝8264348440🔝
Call Girls in Uttam Nagar Delhi 💯Call Us 🔝8264348440🔝
 
Chennai Call Girls Alwarpet Phone 🍆 8250192130 👅 celebrity escorts service
Chennai Call Girls Alwarpet Phone 🍆 8250192130 👅 celebrity escorts serviceChennai Call Girls Alwarpet Phone 🍆 8250192130 👅 celebrity escorts service
Chennai Call Girls Alwarpet Phone 🍆 8250192130 👅 celebrity escorts service
 
定制(Lincoln毕业证书)新西兰林肯大学毕业证成绩单原版一比一
定制(Lincoln毕业证书)新西兰林肯大学毕业证成绩单原版一比一定制(Lincoln毕业证书)新西兰林肯大学毕业证成绩单原版一比一
定制(Lincoln毕业证书)新西兰林肯大学毕业证成绩单原版一比一
 
Call Girls In The Ocean Pearl Retreat Hotel New Delhi 9873777170
Call Girls In The Ocean Pearl Retreat Hotel New Delhi 9873777170Call Girls In The Ocean Pearl Retreat Hotel New Delhi 9873777170
Call Girls In The Ocean Pearl Retreat Hotel New Delhi 9873777170
 

Delta v sis safety manual, may 2011

  • 1. D800032X012 May 2011 DeltaV SIS™ Process Safety System Safety Manual
  • 2. Printed in the Republic of Singapore. © Emerson Process Management 1996 - 2011. All rights reserved. For Emerson Process Management trademarks and service marks, go to http://www.emersonprocess.com/home/news/resources/marks.pdf. All other marks are property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, expressed or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the design or specification of such products at any time without notice. Emerson Process Management Distribution Ltd. Process Systems and Solutions Meridian East Meridian Business Park Leicester, LE19 1uX, UK Emerson a.s. European System and Assembly Pieštanská 1202/44 Nové Mesto nad Váhom 91528 Slovakia Fisher-Rosemount Systems, Inc. – an Emerson Process Management company 12301 Research Blvd. Research Park Plaza – Bldg. III Austin, TX 78759
  • 3. Contents iii Contents 1 DeltaV SIS Process Safety System Safety Manual . . . . . . . . . . . . . . . . . . . . . . . . .1 2 Certification Coverage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2.1 Certified Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2.2 SIL Applicability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2.2.1 De-energized to Trip Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2.2.2 Response Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 3 SIL Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 4 Restrictions: SLS 1508 Specific . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 5 Restrictions: All Logic Solver Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 6 Special Features: SLS 1508 Specific . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 7 Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 7.1 Product Life. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 7.2 Environmental Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 7.3 Application Limits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 8 Recommendations for Management of Functional Competency. . . . . . . . . . . . . .7 9 Reporting Product Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 10 Other Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 10.1 Energized to Trip Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 10.1.1 Energized to Trip Applications (with Inverted Logic) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 10.1.2 Energized to Trip Applications (with Auxiliary Relay) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 10.2 High Demand Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 10.2.1 Response Time in High Demand Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 10.2.2 Other Considerations for High Demand Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
  • 4. iv DeltaV SIS Process Safety System Safety Manual
  • 5. DeltaV SIS Process Safety System Safety Manual 1 1 DeltaV SIS Process Safety System Safety Manual This document contains important information on how DeltaV SIS is to be used in a safety instrumented system to place and/or maintain the equipment under control in an appropriate state when expected to do so. The guidelines in this document should be followed when using DeltaV SIS in safety-critical applications. To determine whether this document is the most recent revision applicable to a particular revision of the SLS 1508, compare the part number shown on the cover of this document to the part number found on the SureService Guardian website: https://guardian.emersonprocess.com Log into the Guardian website and look for the DeltaV SIS links under Resources. 2 Certification Coverage 2.1 Certified Components The information in this document applies to hardware and software components of DeltaV SIS that have been certified according to IEC 61508. TUV has certified the SLS 1508 hardware and firmware as suitable for use in safety applications with a maximum Safety Integrity Level (SIL) of 3 (SIL3) according to IEC 61508 Part 1 to Part 7. Refer to https://guardian.emersonprocess.com for a complete listing of the certified SIL compliant and interference free hardware and software components of DeltaV SIS. 2.2 SIL Applicability The maximum Safety Integrity Level for the SLS 1508: Refer to “Other Applications” on page 8 for SIL ratings and a discussion on energized to trip applications. Simplex Redundant De-energized to Trip application SIL3 SIL3
  • 6. 2 DeltaV SIS Process Safety System Safety Manual 2.2.1 De-energized to Trip Applications In de-energized to trip applications the advanced logic solver architecture of the SLS 1508 achieves SIL3 safety in a simplex hardware module. A simplex SLS 1508 provides the hardware fault tolerance and safe failure fraction to meet SIL3 architectural requirements. A redundant SLS 1508 meets SIL3 architectural requirements, utilizing redundancy to increase availability and to reduce false trips. The SIL3 rating applies to both the low and high demand modes of operation. In a de-energized to trip application the safe state for all output channels of a given safety instrumented function (SIF) is off/low. This corresponds to the safe state of output channels if the SLS 1508 needs to remove power in response to a dangerous failure being detected by its advanced diagnostics. Refer to “Engineering Practices” in the DeltaV SIS Process Safety System Users Guide for configuration guidelines for de-energized to trip applications. When higher powered discrete outputs are needed, there are two standard product options that utilize external relay modules as part of the logic solver subsystem. There is a SIL3 option if line monitoring is not needed and a SIL2 option with line monitoring. Refer to Installing Your DeltaV SIS Process Safety System Hardware for more information. SIS module configuration techniques do not change when the auxiliary relays are used in a de-energized to trip function. 2.2.2 Response Time The response time for a SIF should be less than the process safety time. The SIF has a response time associated with the sensor, logic solver, and final element subsystems. The sum of the response times should be less than the process safety time. The response time of the logic solver subsystem is the time between any change on a SIF input channel that should result in a trip and the time that the output channel or channels change to the tripped state. The time is measured from screw terminal to screw terminal. The response time is impacted by the configured scan rate of the SLS 1508 containing the SIS module logic for the SIF. There is some variability due to the alignment of the
  • 7. SIL Verification 3 change at the input screw terminal and I/O scanning in the SLS 1508. The following table shows the maximum response times. Note the following concerning response times for the logic solver subsystem. 1. The response time does not increase if an input channel of the SIF is on an SLS 1508 other than the SLS 1508 driving outputs. 2. If there are multiple SIS modules involved in the SIF with communication using secure parameters, the maximum response time increases by the scan rate of the SLS 1508 containing the secure parameter (not the secure parameter reference). For example, two SIS modules at a 50 millisecond scan rate increases the maximum response time from 175 to 225 milliseconds. If communication is between DeltaV SIS nodes across the remote peer ring (SISNet), there is a potential for the response time to increase by an additional 50 milliseconds. 3. If SIS module logic includes delays such as the trip delay time in voter function blocks, the response time will increase by the length of those delays. 3 SIL Verification In order to verify that a SIF meets the assigned SIL the probability of the SIF failing dangerously is determined. The DeltaV SIS FMEDA Report contains failure rate and other data to help you verify that your safety requirements are being met. It contains the information necessary to do SIL verification calculations for the SIF’s logic solver subsystem, including failure rates by failure category, diagnostic coverage and common cause factors, hardware fault tolerance, and device type. The use of a SIL verification tool is encouraged in order to get the most accurate results possible. Emerson Process Management recommends the exida exSILentia tool (SILVer), whose SIL verification uses Markov analysis and is based on data from the DeltaV SIS FMEDA Report. SLS 1508 scan rate (milliseconds) Maximum response time (milliseconds) 50 175 100 275 150 375 200 475
  • 8. 4 DeltaV SIS Process Safety System Safety Manual The DeltaV SIS FMEDA Report is available at https://guardian.emersonprocess.com. 4 Restrictions: SLS 1508 Specific There are no SLS 1508 specific restrictions. 5 Restrictions: All Logic Solver Systems As with all safety logic solvers, the SLS 1508 is to be used according to the practices required by IEC 61508 and IEC 61511 as summarized below:  As with any logic solver, any modification or change shall be subject to a safety impact analysis to determine all software modules impacted and the necessary re- verification activities. A full functional test of the logic solver configuration may be needed before the logic solver provides the protection function in a running process. Your site acceptance procedures should address functional testing of the applications running in logic solvers. Note It is possible to assess what has changed in the SLS 1508 since the last functional test by examining the CRC values in DeltaV Diagnostics Explorer.  The SLS 1508 provides the ability to download configuration changes on-line. When any safety instrumented function in any logic solver is disabled or bypassed, safety should be provided by alternative means. If a logic solver allows on-line changes, until those changes are verified via functional testing it is assumed that the SIF(s) under change are disabled. For any disabled or bypassed SIF: 1. The equipment under control should be supervised until completion of the functional test (or the assessment of the need to test if a functional test is not required). 2. The process safety time associated with the hazard should be long enough for operators to monitor and react, and thus manually provide the protection function during the bypass or download / functional test.  A periodic proof test should be performed to reveal potentially dangerous faults not detected by continuous runtime diagnostics in the logic solver. The necessary frequency of the proof test is a function of the probability of dangerous failure for the safety instrumented function(s) associated with the logic solver.
  • 9. Special Features: SLS 1508 Specific 5 6 Special Features: SLS 1508 Specific  The SLS 1508 provides a Non-Secure Parameter Reference feature. This is a user- defined parameter type available in SIS modules for non safety-critical use. If a parameter of this type contributes to a safety-critical control action, special consideration is needed in SIS module logic to validate the parameter value. The application programmer should not allow the safety function to be compromised based on the value of a Non-Secure Parameter Reference. Refer to “Engineering Practices” in the DeltaV SIS Process Safety System Users Guide for more information.  Other than the Non-Secure Parameter Reference, all configuration elements available in SIS modules may be used without special consideration in a safety- critical application up to and including SIL3. This includes the Calculation-Logic function block expression language, which is a limited variability language.  The SLS 1508 automatically responds to faults common to all I/O channels, such as malfunction of a processor or a memory failure, by de-energizing all output channels. This leaves output devices under control of the partner when using redundant SLS 1508s. A fault on an output channel will not prevent de- energization in the case of a demand to trip on that channel. There is an automatic, secondary means of de-energization when needed. For detail on fault detection and how the SLS 1508 and DeltaV SIS respond to those faults, refer to “Maintenance Practices” in the DeltaV SIS Process Safety System Users Guide.  The person configuring SIS module logic has influence over the SLS 1508's response to certain faults detected in the SLS 1508 and field instruments. For faults specific to one I/O channel or one field device, the SLS 1508 integrates Bad status with the value on the channel. The SIS module can be configured to respond to Bad status as needed by the application. Configuring the system response to Bad status is a matter of choosing status options, fault state options, and certain time duration values as the application requires. Refer to “Engineering Practices” in the DeltaV SIS Process Safety System Users Guide for more information on configuring the system response to detected faults. The DeltaV SIS book in DeltaV Books Online has detailed information on the features of the function blocks available in SIS modules.  SLS 1508 outputs configured as HART Two-state Output channels are intended for certain final elements. You should physically connect a channel of this type to only a Fisher Controls DVC6000 SIS (firmware revision 6 or later) or a digital valve controller certified by Emerson Process Management as being equivalent.
  • 10. 6 DeltaV SIS Process Safety System Safety Manual Refer to “Engineering Practices” in the DeltaV SIS Process Safety System Users Guide for more information on using digital valve controllers with the SLS 1508.  The DeltaV SIS secure write server is certified for use in safety rated applications up to SIL3. Only the secure write server can make runtime changes to parameters in the SLS 1508 made from DeltaV workstations, including maintenance bypasses, operator resets, and all other parameters that are allowed to be changed at runtime. The secure write capability is integrated with DeltaV Operate dynamos and faceplates for the advanced SIS function blocks and in DeltaV Control Studio Online/Debug for SIS modules. Note It is not necessary to do a functional test after a secure write is done. You can be certain that the parameter value in the SLS 1508 is the value confirmed.  The secure write operation is in addition to DeltaV security. The user who is logged in at the DeltaV workstation needs to have the software key to the lock associated with the writable parameter and parameter field.  DeltaV SIS has a built-in bypass facility for managing maintenance overrides. A bypass allows a maintenance activity such as calibration, proof testing, or repair of a transmitter or other sensor to take place without a concern for a spurious trip. Bypasses in SIS module logic in the SLS 1508 can be set and cleared from DeltaV workstations using a secure write operation. Refer to “Operations Practices” in the DeltaV SIS Process Safety System Users Guide for additional information on the DeltaV SIS bypass facility.  A proof test of the SLS 1508 is conducted by forcing the logic solver to go through reset and power-up testing. This is initiated by using a context menu command from DeltaV Diagnostics Explorer and has no adverse impact to a running process when redundant SLS 1508s are used. An automatic proof test is optional for redundant SLS 1508s based on a configured proof test interval. Refer to “Maintenance Practices” in the DeltaV SIS Process Safety System Users Guide for more information on proof testing and additional topics on recommended operations and maintenance practices for DeltaV SIS. 7 Limits 7.1 Product Life The useful lifetime of the critical components of the SLS 1508 is 20 years.
  • 11. Recommendations for Management of Functional Competency 7 7.2 Environmental Conditions Refer to Installing Your DeltaV SIS Process Safety System Hardware for limits on environmental conditions. 7.3 Application Limits DeltaV engineering tools ensure that application limits are not exceeded. There are no requirements to consider to prevent limits from being exceeded. Refer to “System Capacities” in the Configuration book in DeltaV Books Online for the SIS application limits. 8 Recommendations for Management of Functional Competency DeltaV SIS is intended to be used in accordance with a defined safety life cycle such as that described in IEC 61511. IEC 61511 requires that persons, departments or organizations involved in safety life-cycle activities shall be competent to carry out the activities for which they are accountable. Emerson Process Management strongly recommends that the following be considered when developing a competency management program in order for DeltaV SIS users to achieve IEC 61511 compliance. Competence of Persons - Engineering All persons involved in the initial implementation or modification of the application software should have appropriate training. Opportunities for training include reading the DeltaV SIS Process Safety System Safety Manual, the DeltaV SIS Process Safety System Users Guide, DeltaV Books Online, and attending a training class lead by Emerson Process Management certified personnel. Formal training is available through Emerson Process Management Educational Services. For information, visit: http://www.emersonprocess.com/education/contacts_centers.asp Competence of Persons - Installation and Hardware Maintenance All persons involved in installation and hardware maintenance activities should have appropriate training. Opportunities for training include reading the DeltaV SIS Process Safety System Users Guide, Installing Your DeltaV SIS Process Safety System Hardware, reading DeltaV Books Online, and attending a training class lead by Emerson Process Management certified personnel. Formal training is available through Emerson Process Management Educational Services.
  • 12. 8 DeltaV SIS Process Safety System Safety Manual Competence of Persons - General All persons involved in any aspect of DeltaV SIS, including engineers, operators, supervisors, maintenance personnel, and system administrators, should have training in the importance of safety instrumented systems. All persons should have specific training in the procedures for which they are responsible. DeltaV system administrators should ensure that all individuals having security keys for DeltaV SIS activities are trained and competent. For technical support contact information and for reporting product issues, visit: http://www.emersonprocess.com/systems/support/ratecard.htm 9 Reporting Product Issues Refer to “Maintenance Practices” in the DeltaV SIS Process Safety System Users Guide for more information on reporting product issues. 10 Other Applications 10.1 Energized to Trip Applications The maximum Safety Integrity Levels for the SLS 1508 in energized to trip applications are as follows: 10.1.1 Energized to Trip Applications (with Inverted Logic) When the safe state for an SLS 1508 output channel is on/high, the application is energized to trip from the perspective of the output channel. Energized to trip output channels require SIS module configuration to drive the SLS 1508 output channel value on/high to achieve the safe state. The SIS module logic essentially inverts the output signals as compared to de-energized to trip logic. Simplex Redundant With inverted logic Low demand mode SIL3 SIL3 High demand mode ___ SIL1 With auxiliary relay SIL2 SIL2
  • 13. Other Applications 9 If the SLS 1508 removes power in response to detecting a dangerous failure in an application with inverted SIS module logic, the equipment under control remains in the normal operating state. The DeltaV system annunciates a dangerous failure in a SLS 1508 by means of a hardware alarm. In response to the alarm operators can manually take the process to the safe state if the repair cannot be completed within the mean time to repair (MTTR) used for SIL verification. Refer to “Engineering Practices” in the DeltaV SIS Process Safety System Users Guide for configuration guidelines for energized to trip applications using inverted logic. Refer to “Maintenance Practices” in the DeltaV SIS Process Safety System Users Guide for more information on DeltaV SIS fault annunciation. 10.1.1.1 Using Inverted Logic in Low Demand Mode In the low demand mode of operation there is ample time to manually respond to an annunciated dangerous failure. Credit can be taken for SLS 1508 diagnostics such that dangerous detected failures are included in the safe failure fraction. The SLS 1508 meets SIL 3 architectural requirements as simplex or redundant. 10.1.1.2 Using Inverted Logic in High Demand Mode In the high demand mode the process safety time or demand rate may not allow time for a manual response following the annunciation of a dangerous failure. Emerson Process Management recommends that no credit be taken for diagnostics when using inverted logic in high demand mode. A redundant hardware configuration is required for safety rated applications. In a redundant configuration either of the two hardware modules is able to drive the output channel on/high, providing the hardware fault tolerance and safe failure fraction to meet SIL 1 architectural requirements. The amount of time operating without an available partner SLS 1508 should be limited to the MTTR used in SIL verification. 10.1.2 Energized to Trip Applications (with Auxiliary Relay) If a higher powered discrete output is needed for an energized to trip application, an Auxiliary Relay DTA-Inverting and Auxiliary Relay Diode module can be combined with the SLS 1508. In this case the inverting of the output signal is done through external hardware. The SIS module is configured to drive the outputs off/low to achieve the safe state, the same as in a de-energized to trip application. The logic solver subsystem meets a SIL2 architectural requirement with a simplex or redundant SLS 1508 in both low and high demand modes. Refer to Installing Your DeltaV SIS Process Safety System Hardware for more information.
  • 14. 10 DeltaV SIS Process Safety System Safety Manual Refer to “Engineering Practices” in the DeltaV SIS Process Safety System Users Guide for configuration guidelines for energized to trip applications using the auxiliary relay modules. 10.2 High Demand Mode 10.2.1 Response Time in High Demand Mode The response time discussion for low demand mode on page 2 also applies when operating in high demand mode. Although the probability of an undetected fault being present at the time of a demand is extremely low, you should assume a fault may be present when allocating the response time for the logic solver subsystem in high demand mode applications. The maximum fault detection plus reaction time of the SLS 1508 for any scan rate is 400 milliseconds. Therefore, for high demand mode applications, you should allocate an additional 400 milliseconds for the logic solver subsystem response time, for example, 575 milliseconds for an SLS 1508 whose scan rate is 50 milliseconds. Note that the recommendation to include the fault detection plus reaction time in the response time does not apply in the low demand mode. 10.2.2 Other Considerations for High Demand Mode The high demand mode of operation is defined by IEC 61508. High demand mode may apply by definition or whenever it is more appropriate to treat a SIF as operating in high demand mode instead of low demand. The following applies to both de- energized to trip and energized to trip applications. The SLS 1508 does not automatically de-energize outputs when faults are detected on input channels because the fault may originate in field devices or field wiring. Instead, the SLS 1508 integrates Bad status with the channel value. SIS module logic can be configured to respond appropriately to Bad status on input channels. In high demand mode applications the allowed repair time for faults detected on input channels should be limited by SIS module configuration so that the SLS 1508 will drive applicable outputs to the safe state if the repair cannot be completed in time. Refer to “Engineering Practices” in the DeltaV SIS Process Safety System Users Guide for more information on configuring the system response to detected faults.