  1. 1. fluid sensors and diagnostic systems bus, identification and control systems position sensors and object recognition www.ifm.com Innovations 2012
  2. 2. 2 *Some offered information is available country-specific. www.ifm.com Information around the clock and around the globe in 23 languages on the internet. • Information - product innovations - company news - exhibition info - locations - jobs • Documentation - data sheets - operating instructions - manuals - approvals - CAD data • Communication* - request for documents - recall service - live advice - newsletter • Selection - interactive product selection aids - configuration tools - data sheet direct • Animation - virtual product animations - flash movies (video sequences) • Application - applications - product recommendations - calculation aids • Transaction* - e-shop processing - e-procurement catalogues
  3. 3. 3 Convenient order processing via the e-shop** on the internet. Secured authentication Customer-related price indication Real time availability check Personal product favourites Online parcel tracking Individual order history Convenient quick input form Simple order processing Management of shipping addresses Confirmations by e-mail **Already available in many countries.
  4. 4. 4 Position sensors and object recognition ... maximum protection in hazardous areas ... safe detection of metal Inductive sensors Magnetic sensors, cylinder sensors ... now in full-metal housing Touch sensors ... capacitive touch sensors for installation on walls ... PMD distance sensor O1D now insensitive to extraneous light ... OG-Cube as AC version Photoelectric sensors Flow sensors ... measurement of liquids up to 180 °C ... space-saving ATEX control monitor with wire-break alarm ... compressed air meter with display and totalizer function ... modular flow monitoring for field applications ... temperature transmitter with 4...20 mA and IO-Link 1.1 ... for fast temperature changes ... hygienic Pt100 sensors with 4-wire connection ... head transmitter – the past; temperature plug – the future Temperature sensors ... PN7 pressure sensor with communication interface IO-Link 1.1 ... 2-wire pressure sensor, display, parameter setting via IO-Link Pressure sensors Fluid sensors and diagnostic systems ... new level sensor, ignores foam and build up ... improved performance, now also with IO-Link ... diagnostic system: oil moisture and temperature sensor Level sensors Object recognition ... the vision sensor – optical object inspection ... fast diagnostic electronics detects machine crash Diagnostic systems 6 - 7 8 - 9 10 - 11 12 - 13 14 - 15 16 - 17 26 - 27 28 - 29 30 - 31 32 - 33 38 - 39 40 - 41 42 - 43 44 - 45 (04.2012) (11.2011) 34 - 35 36 - 37 20 - 21 22 - 23 24 - 25 18 - 19 (11.2011) (04.2012) (04.2012) (04.2012) (04.2012) (04.2012) (11.2011) (11.2011) (04.2012) (11.2011) (11.2011) (11.2011) (04.2012) (04.2012) (11.2011) (04.2012) (11.2011) 46 - 47 (04.2012) (11.2011)
  5. 5. 5 ... AS-i gateways with ultra short transfer times ... AS-i safety made easy Bus system AS-Interface ... standstill safely detected Evaluation systems Bus systems ... RFID with Profibus-DP RF-identification systems ... dialogue module PMD360 NG for mobile vehicles Control systems for mobile vehicles Identification systems Control systems For further technical data please go to: www.ifm.com Evaluation systems, power supplies Connection technology Connection technology ... Y connection cable M12 for hygienic and wet areas ... Y connection cable M12 for factory automation 48 - 49 58 - 59 60 - 61 (04.2012) (11.2011) (11.2011) (11.2011) (04.2012) (04.2012) (04.2012) 50 - 51 52 - 53 54 - 55 56 - 57
  6. 6. 6 Inductive sensors for ATEX 3D (zone 22) and 3G (zone 2). EU-wide explosion protection The ATEX directive 94/9/EC (ATEX) sets out detailed rules for explosion prevention. This sensor family passed a very demanding test series of artificial ageing, 4 joules impact test and subsequent protection rating test. The result: the sensor housings are designed to ensure that, even in the toughest conditions they will not become an ignition source in explosive dusts or gaseous atmospheres. This guarantees maximum pro- tection in hazardous areas. Only safe with the matching connection ifm ecolink series connectors also comply with the strict requirements of the standard and are therefore allowed for use in hazardous areas of the categories 2D, 3D and 3G. product news The 4 joules impact test guarantees high mechanical stability of the housing. Full metal sensors as threaded M12, M18 and M30 types. M12 connector ecolink for ATEX categories 2D / 3D / 3G. High vibration and shock resistance. Maximum protection in hazardous areas. Positionsensorsandobjectrecognition bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition
  7. 7. 7 04.2012 Type Sensing range [mm] Ambient temperature [°C] f [Hz] CategoryHousing material Order no. M12 connector · output function NO · 3-wire DC PNP M12 3 f -40...60100 3D / 3Ghigh-grade stainless steel IF503A M12 Dimensions Length [mm] L = 60 L = 70 6 nf -40...60500 3D / 3Ghigh-grade stainless steel IF505A M18 L = 70 5 f -40...60100 3D / 3Ghigh-grade stainless steel IG510A M18 L = 70 12 nf -40...60500 3D / 3Ghigh-grade stainless steel IG511A M30 L = 70 10 f -40...6050 3D / 3Ghigh-grade stainless steel II502A M30 L = 70 25 nf -40...60250 3D / 3Ghigh-grade stainless steel II503A Threaded housings M12 connector · output function NC · 3-wire DC PNP M12 3 f -40...60100 3D / 3Ghigh-grade stainless steel IF504A M18 L = 60 L = 70 5 f -40...60100 3D / 3Ghigh-grade stainless steel IG512A M30 10 f -40...6050 2D / 3Ghigh-grade stainless steel II504AL = 70 Operating voltage [V DC] 10...36 Current rating [mA] 100 Short-circuit protection, pulsed • Reverse polarity / overload protection • / • Switching status LED yellow (4 x 90°) Protection in hazardous areas IP 67 Protection outside the hazardous area IP 65, IP 67, IP 68, IP 69K Full-metal inductive sensors M12, M18, M30 Common technical data Type Description Order no. Accessories Angle bracket for type M30, stainless steel E10737 Angle bracket for type M12, stainless steel E10735 Angle bracket for type M18, stainless steel E10736 Technical data: Operating voltage: 60 V AC / 60 V DC Nominal current: 2 A Protection rating: IP 67 in locked condition with the matching counterpart. Tightening torque of the nut: 1.2...1.5 Nm Ambient temperature: -20...60 °C Vibration / shock: 750 g, 1 million cycles Cable characteristics: drag chain: > 5 million cycles Type Description Order no. 2 m black, PUR cable EVC04A 5 m black, PUR cable EVC05A 10 m black, PUR cable EVC06A Sockets M12, 4-pole ecolink M12 – the safe connection in ATEX applications. This series of ecolink connectors meets the strict require- ments of the standard and is therefore allowed for use in ATEX areas of the categories 2D, 3D and 3G. It is a simple matter to tighten the connector so far that it complies with the ATEX requirements but cannot be loosened by hand. Observe the recommended tightening torques of 1.2...1.5 Nm! Inductive sensors Positionsensorsandobjectrecognition For further technical data please go to: www.ifm.com
  8. 8. 8 Safe state is reached when damped. Applications The safety function of the sensor allows the user to solve some applications easier than before. If there is no metal in the sensor field, the outputs are enabled. If there is metal in the sensor field, the outputs are safely switched off. Example crane bridge monitoring A fail-safe sensor monitors the position of the crane on the rail. So far the sensor was damped across the whole travel; the sensor was undamped only at the stop posi- tions. This new fail-safe sensor allows mounting of only one damping element each at the beginning and the end of the crane bridge which saves material and moun- ting cost. Fail-safe inductive sensor without magnetic or coded target. 2 OSSD outputs for connection to a safety relay or safety PLC. Diagnosis of different operating states via LED indication. Easy integration in the machine due to flush mounting. Certified to ISO 13849-1 PL d, IEC 61508 SIL 2 and IEC 62061 SIL cl2. Safe detection of metal. Positionsensorsandobjectrecognition bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition product news
  9. 9. 9 11.2011 Technical data (extract) Operating voltage [V] 24 DC (10...30 DC) Short-circuit protection • Reverse polarity protection • Operating mode permanent operation (maintenance-free) Safety-related [1/h] reliability (PFHd) < 1.0E-07 Status indication LED Switching status Operating voltage yellow green Certified to IEC 62061 SILcl2 Complies with the requirements to IEC 61508 SIL2 and to ISO 13849 PL d Inductive fail-safe applications are special applications requiring non-contact and safe detection of a metal object. M12 connector / output function 2 PNP (OSSD) Type / design Enable zone [mm] ProtectionCurrent load [mA] Safe switch-off distance [mm] Ambient temperature [°C] Order no. M18 / f 50> 10 GG851SIP 65 / IP 67< 5 -25...70 Connectors and splitter boxes Type Description Order no. Socket, M12, 2 m black, PUR cable EVC001 Socket, M12, 5 m black, PUR cable EVC002 Socket, M12, 2 m black, PUR cable EVC004 Socket, M12, 5 m black, PUR cable EVC005 Sensor damped: The definition of the safety function is new: The safe state is reached when the damping element (5) is within the safe switch-off distance of < 5 mm (2) is new. The outputs A1 and A2 are switched off (logic "0"). Sensor undamped: If the damping element (5) is in the enable zone (4) at a distance of > 10 mm of the sensing face and if there is no sensor fault, both outputs (OSSD) are enabled (logic "1"). Inadmissible zone Between the safe switch-off distance (2) of < 5mm and the enable zone (4) of > 10 mm there is the inadmissible zone (3). The user has to take measures to exclude the presence of the damping element in this zone. Evaluation unit Type Description Order no. G1501S Safety relay relay G1503S Safety relay semiconductor G1502S Safety relay relay 3 1 4 2 L+ L A1 A2 +24 V IN2 GND IN1 1 Wiring diagram 1) safety-related logic unit "0" LEDs "1" 21 3 4 5 Function of the sensor (1) MTTFd [years] 900 DC/CCF/Cat. 85 % / 65 % / 2 Inductive sensors Positionsensorsandobjectrecognition For further technical data please go to: www.ifm.com
  10. 10. 10 Now in full-metal housing: Reliable switch point even in the event of mechanical tolerances. Full-metal magnetic sensors for early detection of approaching objects. Use in hygienic areas and the food industry Magnetic sensors can be installed behind covers of stain- less steel, non-ferrous metal, plastic, wood or glass which ensures inexpensive and fast mounting. There is no need for bore holes or flush installation. The sensors are also used for cleaning pipes to detect pigs through pipe walls. Mechanically demanding applications Thanks to the tolerant response behaviour, reliable switch- point detection is also ensured with high mechanical tolerances. Long-life applications can be found on tele- scope and swivel arms or industrial trucks for example. Long sensing ranges even through non-magnetisable metals. No mutual interference of the sensors. Temperature-stable and reproducible switch point. IP 69K up to 100 °C in full-metal food-grade housing. Impact, shock and vibration-resistant for demanding applications. Our magnetic sensors begin where others end. Positionsensorsandobjectrecognition bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition product news
  11. 11. 11 11.2011 Type Protection rating Electrical design Iload [mA] Ambient temperature [°C] Order no. M12 connector, 4-pole M12 Sensing range [mm] 60 IP 65, IP 67 DC, PNP 200-25...75 MFS211 Output function NO M12 60 IP 65, IP 67 DC, NPN 200-25...75 MFS209NO M12 60 IP 65, IP 67 DC, PNP 200-25...75 MFS210NC M12 60 IP 68, IP 69K DC, PNP 1000...100 MFT202NO M12 connector, 4-pole M18 70 IP 65, IP 67 DC, PNP 200-25...75 MGS204NO M18 70 IP 65, IP 67 DC, NPN 200-25...75 MGS205NO M18 70 IP 65, IP 67 DC, PNP 200-25...75 MGS206NC M18 70 IP 68, IP 69K DC, PNP 1000...100 MGT203NO Operating voltage [V] 10...30 Current consumption [mA] < 20 Protection class III Switching frequency [Hz] 5000 Short-circuit protection, pulsed • Reverse polarity / overload protection • / • Voltage drop [V] < 2.5 Function display LED yellow (4 X 90°) Housing length [mm] 60 Housing material high-grade stainless steel Hysteresis [% of Sr] 1...10 Common technical dataAccessories Type Description Order no. Mounting clip for type M12, stainless steel (1.4310, 301) E11533 Mounting clip for type M18, stainless steel (1.4310, 301) E11534 Damping element M1.0, samarium cobalt E10749 Damping element M2.0, alnico E10750 Damping element M3.0, barium ferrite E10751 Damping element M4.0, barium ferrite E10752 Damping element M5.0, barium ferrite E10753 Damping element M5.1, barium ferrite with plastic sheathing ABS E10754 Damping element M4.1, barium ferrite / stainless steel (1.4571, 316Ti) E11803 Damping element M3.1, barium ferrite / stainless steel (1.4571, 316Ti) E12291 Connectors and splitter boxes Type Description Order no. Socket, M12, 4-pole, 5 m orange, PVC cable EVT001 Socket, M12, 4-pole, 10 m orange, PVC cable EVT002 Socket, M12, 4-pole, 5 m orange, PVC cable EVT004 Socket, M12, 4-pole, 10 m orange, PVC cable EVT005 Socket, M12, 4-pole, 5 m orange, PVC cable, LED EVT007 Socket, M12, 4-pole, 10 m orange, PVC cable, LED EVT008 Angle bracket for type M12, stainless steel E10735 Angle bracket for type M18, stainless steel E10736 Mounting clamp M12, PC E11047 Mounting clamp M18, PC E11048 Magnetic sensors, cylinder sensors Positionsensorsandobjectrecognition For further technical data please go to: www.ifm.com
  12. 12. 12 Capacitive touch sensors for installation on walls. Technology The capacitive measuring principle detects an approaching human hand. Dynamic touch sensors suppress interfer- ence such as water, layers of ice or foreign bodies to a large extent. However, a gloved hand will still trigger them. Static touch sensors detect hands and objects for as long as the sensing face is damped. Touch sensors also work through glass. Compared to mechanical switches the sen- sors operate without wear. Since they react to contact, no pressure is required for activation which means con- siderably increased ease of use. Non-contact switching, no pressure necessary, wear and tear-free. Optical feedback by LEDs in case of switching. Oil-resistant; protection rating IP 69K; impact and scratch resistant. Easy wiring thanks to tried-and-tested 3-wire technology. Touch sensitive sensors compatible with automotive applications. Positionsensorsandobjectrecognition bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition product news
  13. 13. 13 04.2012 Operating voltage [V DC] 24 (12...36) Current rating [mA] 500 Current consumption [mA] 30 Ambient temperature [°C] -40...85 Protection (front) IP 69K Common technical data Touch sensors Connectors and splitter boxes Type Description Order no. M8 socket, 2 m black, PUR cable EVC150 M8 socket, 5 m black, PUR cable EVC151 M8 socket, 2 m black, PUR cable EVC153 M8 socket, 5 m black, PUR cable EVC154 Other symbols as well as colours of the outer ring on request. The products Description Order no. Touch sensor, mounting on the wall, 2 m PUR cable KT5001 Touch sensor, mounting on the wall, 0.3 m PUR cable with M8 plug KT5002 Dimensions 100 60,2 10 60° 38 120° 4,3 Mounting options Three common M4 cylinder head bolts or tapping screws of Ø 3.9 mm diameter are required to mount the sensor on a wall. LEDs as optical feedback signal that the sensor has been activated. Applications Industry: Here, sensors are used as start / stop buttons on machines. Mobile applications: The sensors can be used as buttons on mobile vehicles and trailers. Furthermore they can be used as stop buttons or door openers. Designs for handicapped people with Braille are possible. Type Applications: Mobile area such as a start /stop button on mobile vehicles and semi-trailers, industrial applications. Positionsensorsandobjectrecognition Dynamic evaluation principle · DC PNP Touch sensor, mounting on the wall, 0.3 m PUR cable with M8 plug KT5007 Dynamic evaluation principle · DC NPN Touch sensor, mounting on the wall, 2 m PUR cable KT5005 Touch sensor, mounting on the wall, 0.3 m PUR cable with M8 plug KT5006 Static evaluation principle · DC PNP For further technical data please go to: www.ifm.com
  14. 14. 14 Object detection of gear parts No interference caused by extraneous light The new generation of the popular O1D sensors with the innovative on-chip time-of-flight measurement system based on PMD technology (Photonic Mixer Device) oper- ates reliably with extraneous light of up to 100,000 lux. This exceeds the values of standard optical sensors many times over and corresponds to the light conditions on a bright summer day with direct sunlight. These sensors can be used in workshops where daylight hits the sensor or target from above. Even reflective objects such as metal surfaces are reliably detected or reflective strips on high-vis vests reliably suppressed. PMD distance sensors O1D now insensitive to extraneous light up to 100,000 lux. Optical distance detection with a range of up to 10 m. 2 switching outputs; one output can be configured as analogue output. Scalable detection range and window function. Can be used in applications needing background suppression. Extensive range of fixing components. Optical distance sensors with sun protection factor. Positionsensorsandobjectrecognition bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition product news
  15. 15. 15 04.2012 Further technical data Type O1D Accessories Type Description Order no. Mounting set for clamp mounting, Ø 12 mm / stainless steel E2D101 Applications: Distance, level and object detection in automation technology. Distance detection Electrical design Background suppression [m] Switching outputs Laser class Sampling rate [Hz] Light spot diameter [mm] Operating range [m] Order no. DC PNP 0...19 2* 2 max. 50, adjustable 6 (for 10 m) 0.2...10 O1D100 DC NPN 0...19 2* 2 max. 50, adjustable 6 (for 10 m) 0.2...10 O1D103 DC PNP > 10...100 2* 2 max. 33, adjustable 6 (for 10 m) 0.2...10 O1D105 DC PNP > 6...100 2* 1 max. 33, adjustable 5 (for 6 m) 0.3...6 O1D155 Operating voltage [V] 10...30 DC Connection M12 connector Protection IP 67 / III Short-circuit protection, pulsed • Reverse polarity / overload protection • / • EMC EN 60947-5-2 Material housing front pane LED window diecast zinc glass polycarbonate Function display Switching status LED Operation LED yellow green Distance value, programming 4-digit alphanumeric display 52 1 2 30 45 2520 4,56 45 59 42 M12x1 30 Dimensions 1) 4-digit alphanumeric display 2) programming buttons Connectors and splitter boxes Type Description Order no. Socket, M12, 2 m black, PUR cable EVC001 Socket, M12, 5 m black, PUR cable EVC002 Socket, M12, 2 m black, PUR cable EVC004 Socket, M12, 5 m black, PUR cable EVC005 Cube for mounting on an aluminium profile, M10 thread, diecast zinc E20951 Mounting adapter, G1A process connection, stainless steel E21224 Protective cover, plastic, PMMA E21133 Protective cover, glass E21171 Cooling and protection box, aluminium E21248 Socket, M12, 2 m orange, PVC cable EVT064 Socket, M12, 5 m orange, PVC cable EVT001 Socket, M12, 2 m orange, PVC cable EVT067 Socket, M12, 5 m orange, PVC cable EVT004 Object detection DC PNP > 10...100 1 2 1 6 (for 10 m) 0.2...10 O1D101 DC NPN > 10...100 1 2 1 6 (for 10 m) 0.2...10 O1D104 Level detection DC PNP > 10...100 2* 2 max. 33, adjustable 6 (for 10 m) 0.2...10 O1D300 * one switching output can be configured as analogue output (0...10 V or 4...20 mA) Photoelectric sensors Positionsensorsandobjectrecognition For further technical data please go to: www.ifm.com
  16. 16. 16 2-wire photoelectric sensor in metal housing with M18 thread. New version in 2-wire AC The newly developed 2-wire output stage with a leakage current of only 1.7 mA allows for the sensor also to be used in alternating current networks. Robust metal housing This sensor is optimised for use in harsh industrial environ- ments. The powerful technology together with the small housing design provides more flexibility for machine build- ing. High optical performance Thanks to the minimal drift when detecting light or dark objects, the sensor achieves long ranges as well as a very good repeatability. Voltage supply 20...250 V AC in 2-wire technology. Small, compact and robust: a high performance sensor. Through-beam, retro-reflective and diffuse reflection sensors (background suppression). Fixed ranges for quick set-up. Universal mounting and large selection of fixing accessories. OG-Cube as AC version. Positionsensorsandobjectrecognition bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition product news
  17. 17. 17 04.2012 Applications: Conveying, packaging machinery, automotive and materials handling. Diffuse reflection sensor with background suppression · 1/2" connector · 2-wire AC Type OG-Cube Light spot diameter [mm] Light-on / dark-on mode Function display LED Order no. 11* OGH080 Range [m] 0.1 (fixed) light-on yellow 800* OGS080 – 20 (fixed) 20 (fixed) – dark-on green yellow OGE080 Operating voltage [V AC] 20...250 Type of light red light 633 nm Current rating [mA] 200 Voltage drop [V] < 8 Ambient temperature [°C] -25...60 Minimum load current [mA] 5 Leakage current / [mA] current consumption < 1.7 Dimensions (W x H x D) [mm] 19.1 x 52.6 x 36.9 Accessories Type Description Order no. Mounting rod, 100 mm, Ø 12 mm, M10 thread, stainless steel E20938 Mounting rod, 200 mm, Ø 12 mm, M10 thread, stainless steel E20940 Common technical data Housing materials zinc alloy, PEI Switching frequency [Hz] 20 11* OGH0810.1 (fixed) dark-on yellow 20 – 30 Protection rating, protection class IP 67,II IP 67,II IP 67,II IP 67,II –20 (fixed) light-on yellow OGE08130 IP 67,II Through-beam sensor – transmitter · 1/2" connector Through-beam sensor – receiver · 1/2" connector · 2-wire AC Prismatic reflector, Ø 80 mm, plastic E20005 Cube for mounting on an aluminium profile, M10 thread, diecast zinc E20951 Connectors and splitter boxes Type Description Order no. Socket 1/2", 2 m, PUR cable E12282 Socket 1/2", 5 m, PUR cable E10210 Socket 1/2", 10 m, PUR cable E12286 Socket 1/2", 5 m, PVC cable E10200 Socket 1/2", 10 m, PVC cable E10261 Socket 1/2", 5 m, PVC cable E10191 Socket 1/2", 10 m, PVC cable E11661 Retro-reflective sensor with polarisation filter · 1/2" connector · 2-wire AC 160* OGP0804 (fixed) dark-on yellow 30 160* OGP0814 (fixed) light-on yellow 30 IP 67,II IP 67,II * at maximum range Photoelectric sensors Positionsensorsandobjectrecognition Clamp for mounting rod Ø 12 mm, diecast zinc, steel E20721 Clamp for mounting rod Ø 12 mm, high-grade stainless steel E21207 Clamp for mounting rod Ø 12 mm, diecast zinc, steel E20720 Clamp for mounting rod Ø 12 mm, high-grade stainless steel E21206 For further technical data please go to: www.ifm.com
  18. 18. 18 The vision sensor checks if the chocolate mould is empty before it is refilled. Optical object inspection for packaging, manufacturing and quality control. Stand-alone unit with integrated lighting and evaluation in a robust, industrially compatible IP 67 housing for use in the tem- perature range of -10...60 °C. User-friendly parameter setting All parameters can be set conveniently via a menu-guided parameter setting software. Object recognition The blob analysis used determines the selected character- istics of objects. They allow to check the presence, size, position or completeness of the objects. Ethernet process interfaces The Ethernet interface also provides remote maintenance with storage of error images and evaluation data, an up- date option for the sensors as well as the process image for the connection of programmable logic controllers. Positionsensorsandobjectrecognition bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition Stand-alone unit with integrated illumination. For inspection tasks with variable features. Compact and robust design. User-friendly parameter setting. Integrated Ethernet process interfaces (TCP/IP, Ethernet IP). Vision sensor takes a closer look at your production. product news
  19. 19. 19 04.2012 Applications: Monitoring presence, completeness, position, size and quality as well as sorting tasks. Switching outputs PNP · Field of view size [mm] · Resolution from 0.1 mm Common technical data Operating voltage [V] 24 DC ± 10 % Detection rate [Hz] max. 10 Type of sensor CMOS image sensor black/white, 640 x 480 Motion speed [m/s] typ. 1 Function display LED 7 Current rating [mA] 100 (per switching output) Current consumption [mA] < 300 Ambient temperature [°C] -10...60 Protection IP 67, III housing Material front lens LED window diecast zinc glass polycarbonate Switching inputs (configurable) max. 2 , 24 V Switching outputs (configurable) max. 5, 24 V Connection external lighting DC 24 V Parameter setting interface Ethernet TCP/IP / Ethernet IP Dimensions [mm] 60 x 42 x 53 (59) Connectors and splitter boxes Type Description Order no. M12 socket, 2 m, PUR cable, 8-pole E11950 M12 socket, 5 m, PUR cable, 8-pole E11807 Parameter setting cable, 2 m, M12 D-coded / RJ45, cross-link E11898 Accessories Type Description Order no. Operating software for image sensor E2V100 Object recognition Positionsensorsandobjectrecognition Stainless steel mounting set for rod mounting Ø 12 mm E2D110 Stainless steel mounting set for rod mounting Ø 14 mm E2D112 Clamp linking ring, high-grade stainless steel E21076 E21110 Clamp, high-grade stainless steel, Ø 12 mm Mounting rod, 150 mm, Ø 12 mm E21111 Mounting rod, 200 mm, Ø 12 mm E21112 Mounting rod, 300 mm, Ø 12 mm E21113 Diffuser Protective plastic cover Protective glass cover Mounting rod, 100 mm, Ø 12 mm, M10 thread, stainless steel E20938 Mounting rod, 100 mm, Ø 14 mm, M12 thread, stainless steel E20939 Ethernet cable, 2 m, M12 D-coded E21138 Ethernet cable, 5 m, M12 D-coded E21139 Ethernet cable, 10 m, M12 D-coded E21137 Ethernet adapter, M12 / RJ45, angled E21140 E21165 E21166 E21168 50 75 100 200 400 1000 2000 Operating distance [mm] Order no. O2V100 O2V102 O2V104 Switching outputs NPN · Field of view size [mm] · Resolution from 0.1 mm O2V101 O2V103 O2V105 Type of light white light white light 16 x 12 33 x 24 24 x 18 50 x 36 32 x 24 66 x 47 64 x 48 132 x 94 128 x 96 264 x 189 320 x 240 660 x 472 640 x 480 1320 x 945 – 15 x 11 20 x 15 40 x 30 80 x 60 200 x 150 400 x 300 16 x 12 33 x 24 24 x 18 50 x 36 32 x 24 66 x 47 64 x 48 132 x 94 128 x 96 264 x 189 320 x 240 660 x 472 640 x 480 1320 x 945 – 15 x 11 20 x 15 40 x 30 80 x 60 200 x 150 400 x 300 For further technical data please go to: www.ifm.com
  20. 20. 20 Adjustable point level sensor for hygienic applications. Level under control The new hygienic point level sensor LMT safely monitors the level in storage tanks or protects pumps against run- ning dry. Its compact sensor tip allows integration even in small DN25 pipes. Versatile sensor for all media The LMT121 can be simply adjusted to virtually any liquid, viscous medium or bulk material thanks to IO-Link. Each of the two switching outputs can be set independently of each other so it is also possible to differentiate between two different media. The parameters can be set with IO- Link and USB interface accessory E30396. Food-grade The sensor with its high-quality housing materials such as high-grade stainless steel (316L / 1.4404) and PEEK meets all requirements for hygienic areas. A lasered type label for durable legibility as well as the high protection rating IP 68 / IP 69K for cleaning processes are natural. Identification of different media by two independently adjustable switch points. Hygienic design with maintenance-free sealing concept. Robust level probe is shock and vibration resistant. Resistant to foam and deposits. Easy mounting thanks to orientation-independent installation. New level sensor, ignores foam and build up. Fluidsensorsanddiagnosticsystems bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition product news
  21. 21. 21 04.2012 Process connection Maximum process pressure [bar] Application Protection Order no. M12 connector · output function 2 x programmable · 4-wire DC PNP · IO-Link 1.1 * preset for sugary, sticky media such as honey, sugar syrup, nougat spread Level sensors Fluidsensorsanddiagnosticsystems Accessories Type Description Order no. Adapter G 1/2 I – Clamp 1"–1.5" E33401 Adapter G 1/2 I – Clamp 2" E33402 Welding adapter ball, G 1/2 E30055 Welding adapter collar, G 1/2 E30056 Welding adapter, cylindrical, G 1/2 E43300 Welding adapter, cylindrical for pipes, G 1/2 E43301 Adapter G 1/2 I – G 3/4 A E43302 Adapter G 1/2 I – G 1 A E43303 Adapter G 1/2 I – DIN 11851 DN25 E43304 Adapter G 1/2 I – DIN 11851 DN40 E43305 Adapter G 1/2 I – Varivent D50 E43306 Adapter G 1/2 I – Varivent D68 E43307 Welding mandrel / aid E43314 Welding adapter, cylindrical, G 1/2 (3-A) E43309 Welding adapter, cylindrical for pipes, G 1/2 (3-A) E43310 Adapter G 1/2 I – Clamp 1"–1.5" (3-A) E43311 Adapter G 1/2 I – Clamp 1"–2" (3-A) E43312 Accessories 3-A Type Description Order no. Medium temperature [°C] Hydrous media -40...85 / 150 (1 h) Medium temperature [°C] Oils, fats, bulk materials -40...100 / 150 (1 h) Housing materials PEEK, high-grade stainless steel (316L/1.4404), PA12, FPM Materials (wetted parts) PEEK Shock resistance [g] 50 Vibration resistance [g] 20 Ambient temperature [°C] -40...60 EMC closed tanks: open tanks: EN 6100-6-2:2005 EN 6100-6-3:2006 EN 6100-6-4:2006 Operating voltage [V] 18...30 DC Current rating [mA] 100 Further technical data Connectors and splitter boxes Type Description Order no. Socket, M12, 5 m orange, PVC cable EVT001 Socket, M12, 10 m orange, PVC cable EVT002 Socket, M12, 5 m orange, PVC cable EVT004 Socket, M12, 10 m orange, PVC cable EVT005 Socket, M12, 5 m orange, PVC cable, LED EVT007 Socket, M12, 10 m orange, PVC cable, LED EVT008 G 1/2 -1...25 adjustable* IP 68 / IP 69K, III LMT121 Welding adapter, collar, G 1/2 (3-A) E43315 Adapter G 1/2 I – 3/4 NPT E43313 Parameter-setting systems Type Description Order no. IO-Link interface, current consumption from USB port E30396 Memory plug, parameter memory for IO-Link sensors E30398 For further technical data please go to: www.ifm.com
  22. 22. 22 Application efector gwr operates to the principle of guided wave radar and measures the level using electromagnetic pulses in the nanosecond range. The sensor is suited to continuous level monitoring in almost all liquids. Mounting The sensor is directly mounted in the tank using a process connection or flange plate. If necessary, the sensor rod can be easily shortened and adapted to the tank by the user. Setting Settings of all parameters as well as programming of the switch points and indication of the current level are carried out via a 4-digit alphanumeric display. In addition, the sensor can also be configured, documen- ted and the data record stored via IO-Link or the USB interface E30396. Fluidsensorsanddiagnosticsystems bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition Improved performance, now also with IO-Link. Versions with 2 or 4 switching outputs or analogue output 4...20 mA / 0...10 V. Easy operation via the user menu. Direct indication of the current level on the LED display. Sensor lengths up to 160 cm. If necessary, the sensor rod can be cut to length by the user. High flexibility due to modular sensor system. product news
  23. 23. 23 04.2012 Applications: aqueous media, coolants, cleaning agents, oils*. Accessories Type Description Order no. Connectors and splitter boxes Type Description Order no. Current consumption [mA] < 80 Dielectric constant medium 2...20* > 20 Operating temperature [°C] 0...60 Medium temperature [°C] 0...80 / (90 peak) Materials in contact with the medium stainless steel (303S22), PTFE, NBR Housing materials FKM, NBR, PBT, PC, TPE-V, stainless steel (304S15), PTFE, PEI Power-on delay time [s] 3 Operating voltage [V] 18...30 DC Current rating [mA] 200 Further technical data Socket, M12, 4-pole 2 m black, PUR cable Socket, M12, 4-pole 5 m black, PUR cable Socket, M12, 4-pole 2 m black, PUR cable, LED Socket, M12, 4-pole 5 m black, PUR cable, LED Level sensors Fluidsensorsanddiagnosticsystems EVC004 EVC005 EVC007 EVC008 Process connection Switch point accuracy [cm] Repeatability [cm] Maximum vessel pressure [bar] Protection Order no. M12 connector · output function 2 x programmable · 4-wire DC PNP M12 connector · output function 4 x programmable · 8-wire DC PNP G 3/4 ± 1.5 ± 0.5 -1...4 IP 67, III LR7000 Socket, M12, 8-pole 2 m black, PUR cable E11231 Socket, M12, 8-pole 5 m black, PUR cable E11232 G 3/4 ± 1.5 ± 0.5 -1...4 IP 67, III LR8000 M12 connector · output function 1 x programmable / 1 x analogue 4...20 mA / 0...10 V · 4-wire DC PNP G 3/4 ± 1.5 ± 0.5 -1...4 IP 67, III LR3000 * A coaxial pipe is required for the unit to function correctly in low dielectric media. Flange plate, LR 73-90 E43201 Flange plate, LR 73-90, NPT E43206 Flange plate, LR 65-80 E43202 Probes (to be ordered separately) Type Description stainless steel (303S22) Order no. E43203240 mm E43204450 mm E43226300 mm E43205700 mm E43227500 mm E432071000 mm E432081200 mm E432091400 mm E432101600 mm Coaxial pipes (to be ordered separately) Type Description stainless steel (303S22) Order no. IO-Link Device type of transmission COM2 (38.4 kbaud) E43211240 mm E43212450 mm E43213700 mm E432141000 mm E432151200 mm E432161400 mm E432171600 mm E43218450 mm E43228300 mm E43219700 mm E43229500 mm E432201000 mm E432211600 mm G 3/4 G 3/4 NPT 3/4" For further technical data please go to: www.ifm.com
  24. 24. 24 Combined oil moisture and temperature sensor. Application Water is generally not wanted in hydraulic liquids and lubricants. High concentrations of water can seriously affect operation or even cause damage. Measuring principle The sensor measures the relative humidity in the oil in the range of 0...100 % by means of a capacitive measur- ing element. At 0 % the oil is absolutely without any water content. At 100 %, however, the medium is com- pletely saturated. No more water is dissolved and is then present as free water. Besides the relative humidity the sensor also outputs the medium temperature as an analogue signal. Continuous condition monitoring of oils. Two analogue outputs (4...20 mA) for relative humidity and temperature. Wide input voltage range 9...33 V DC. Medium temperature -20...100 °C. G 3/4" process connection for direct mounting. Ensure oil remains dry! Fluidsensorsanddiagnosticsystems bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition product news
  25. 25. 25 11.2011 Wiring diagram Application: Oil moisture and temperature monitoring of mineral oils, synthetic esters and bio oils. Process connection Pressure resistance [bar] Output function Protection Medium temperature Oil Ambient temperature Order no. M12 connector, 8-pole G 3/4 10 4...20 mA IP 67 -20...85 °C -20...100 °C (short-term 120 °C) LDH100 Accessories Type Description Order no. Assembly block G 3/4 E43400 Connectors and splitter boxes Type Description Order no. Measuring resolution Rel. humidity [%] Temperature [K] 1 0.1 Current consumption [mA] < 60 Materials (wetted parts) aluminium, HNBR, polyurethane resin, epoxy resin EMC EN 13309:2000-11 Measuring accuracy Rel. humidity [%FS*] Temperature [%FS*] ± 3 ± 2 Operating voltage [V] 9...33 DC Measuring range Rel. humidity [%] Temperature [°C] 0...100 -20...120 Further technical data screen L+ L Out 1 Out 2 1 8 7 6 3 4 5 2 n.c. n.c. n.c. n.c. Socket M12, 8-pole 2 m PUR, shielded E80021 Socket M12, 8-pole 10 m PUR, shielded E11855 Socket M12, 8-pole 2 m PUR, shielded E80022 Dimensions 32 42 M12x1 21,6 54 44 43 14 G43 *FS = Full scale Fluidsensorsanddiagnosticsystems Level sensors For further technical data please go to: www.ifm.com
  26. 26. 26 Measurement of liquids up to 180 °C. Process cooling in an induction furnace. Mechatronic flow sensor The flow sensor works to the principle of spring-support- ed piston: the piston, located in the valve seat in the housing, is lifted by the flowing medium against the spring resistance. The piston position is monitored via a magnetic-field sensor and is output as an analogue signal. The spring resistance forces the piston to return to its original position with decreasing flow. This ensures posi- tion-independent installation of the flow sensor preven- ting backflow. Due to the temperature decoupling of the transducer from the electronics, this sensor is especially suitable for media in high temperature applications of up to 180 °C. The units are maintenance-free. For flow ranges of 0.3...25 l/min. Analogue output signal 4...20 mA. Simple and robust. Fast response time ≤ 10ms. Pressure ranges up to 15 bar. Mechatronic flow sensor for high temperatures. Fluidsensorsanddiagnosticsystems bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition product news
  27. 27. 27 04.2012 Common technical data Operating voltage [V] 24 DC (-15 % / + 10 %) Short-circuit protection • Materials in contact with the medium stainless steel 304/1.4301; nickel-plated brass; PPS; O-ring: FPM Ambient temperature [°C] 0...60 Response time [s] < 0.01 Current consumption [mA] < 30 Reverse polarity / overload protection • / • Type SBT, SBM Dimensions 35 65 M12x1 M12x1 13 76,5 13 Rp43 Rp43 L+ L 1 3 2 Wiring SBT633 Process connection Medium temperature [°C] Accuracy [% of the final value] Pressure resistance [bar] Order no. Connection cable 0.3 m with M12 connector · analogue function mode 4...20 mA Rp 3/4 20...180 ± 5 15 SBT633 Protection rating, protection class IP 67, III G 3/4 20...180 Measuring range [l/min] 0.3...25 0.3...25 ± 5 15 SBM613*IP 67, III Applications: Liquids (water, glycol solutions). * Only measuring insert for OEM solutions, no replacement part. 35 65 M12x1 M12x1 20 407047 157 30 G 43 SBM613 43 2 1 Thermographic diagram of an SBT type flow sensor. Fluidsensorsanddiagnosticsystems Flow sensors For further technical data please go to: www.ifm.com
  28. 28. 28 Space-saving ATEX control monitor with wire-break alarm. Flow and temperature monitoring in gas supply pipes. Easy handling and high functionality A pushbutton is used to set the flow range and adjust the switch. Nominal flow range and the switch point are indicated locally by a multicolour LED display. In addition, the user can set a temperature switch point. The signals are output via potential-free relays. In combination with the SP flow probes this monitor offers high repeatability of the switch points. Separate response settings for liquids and gases ensure the set up is tailored to its medium. The integrated teach function allows the flow monitor to be further individually adapt- ed to differing applications. Integrated wire-break monitoring between flow probes and the monitor plus electronic locking of the settings provide additional safety and full confidence in the out- put status. For all sensors of the type SP. Flow, temperature and wire-break monitoring. ATEX approval group II, category 2G. Potential-free relay outputs with changeover contact. Improved performance thanks to integrated medium selection. Flow and temperature monitor for ATEX applications. Fluidsensorsanddiagnosticsystems bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition product news
  29. 29. 29 04.2012 Temperature gradient [K/min] 30 Medium temperature [°C] -20...70 Protection IP 65 / IP 67 Materials in contact with the medium high-grade stainless steel (316L/1.4404) Housing materials high-grade stainless steel (316L/1.4404) Marking of the unit II 2G Ex ia IIC T4 Gb Response time [s] 1...10 Approvals ZELM 11 ATEX 0467 IECEx ZLM 11.0005 Further technical data type SP321A Dimensions G21 95 15 45 20 27 7,7 2 7 8 9BK BU BN WH Wiring SP321A Process connection Setting range liquids [cm/s] Pressure resistance [bar] Order no. Flow sensor for connection to a control monitor · connection cable 6 m G 1/2 A 3...300 30 SP321A ATEX approval group II, category 2G Setting range gases [cm/s] 100...15000 Applications: Liquids and gases. 107 113,6 35,2 104,5 LEDs SR307A 1) SR307A / VS4000 2) SP321A 22 23 24 28 29 30 31 32 34 35 36 2 7 8 9BK BU BN WH 1 2 3 L L+ Wiring Dimensions Output function relay Operating voltage [V] 24 DC Current consumption [mA] 100 Storage temperature [°C] -25...80 Ambient temperature [°C] -20...60 Protection housing terminals IP 20 IP 20 Marking of the unit II (1) G [Ex ia Ga] IIC Contact rating [A] 4 (250 V AC cos phi >0.7); 0.2 (250 V DC); 4 (24 V DC) Approvals ZELM 11 ATEX 0466 IECEx ZLM 11.0004 Technical data type SR307A Applications: flow, temperature and wire-break monitoring Control monitor for flow sensors 1) flow monitoring 2) fault monitoring 3) temperature monitoring 1) LED bar display 2) setting buttons Note: The switching amplifier must be mounted outside the Ex zone! Fluidsensorsanddiagnosticsystems Flow sensors For further technical data please go to: www.ifm.com
  30. 30. 30 Compressed air meter with display and totalizer function. Argon consumption measurement in a laser welding system. Calorimetric measuring principle The compressed air meter detects the standard volume flow directly (according to ISO 2533 and DIN 1343). This makes corrections, in case of temperature or pressure fluctuations, unnecessary. The high measurement dy- namics of the system enable the reliable detection of even minute quantities, e.g. leakage. High accuracy and repeat- ability are ensured by the integration of the measure- ment sensor’s key elements into a defined pipe length. Measuring compressed air consumption in air supply lines We offer additional compressed air sensors for larger measuring ranges on request, especially for supply and air supply lines. As an option compressed air sensors with exchangeable electronics, allowing subsequent calibration under oper- ating pressure, can also be used. Measurement to ISO 2533 and DIN 1343 possible. For compressed air in industrial use, argon, carbon dioxide, nitrogen. Large measuring range up to 700 Nm3/h. Larger measuring ranges on request. Fast response time and high response sensitivity. Volumetric flow quantity, flow velocity and temperature indication. To prevent your money from dissolving into thin air. Fluidsensorsanddiagnosticsystems bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition product news
  31. 31. 31 11.2011 Measuring range [Nm3/h] Pulse value [m3] Measuring accuracy [% of the final value] Process connection Order no. Application: compressed air in industrial use, air quality DIN 8573-1, class 141 (measurement error: value A) / class 344 (measurement error: value B) 0.06...15 0.001...1 000 000 A): ± (3 % MV + 0.3 % VMR) / B): ± (6 % MV + 0.6 % VMR) G 1/4 SD5000 0.25...75 0.001...1 000 000 A): ± (3 % MV + 0.3 % VMR) / B): ± (6 % MV + 0.6 % VMR) R 1/2 SD6000 0.25...75 0.001...1 000 000 ± (15 % MV + 1.5 % VMR) G 1/2 SD6050 0.75...225 0.003...3 000 000 A): ± (3 % MV + 0.3 % VMR) / B): ± (6 % MV + 0.6 % VMR) R 1 SD8000 1.3...410 0.005...4 000 000 A): ± (3 % MV + 0.3 % VMR) / B): ± (6 % MV + 0.6 % VMR) R 1 1/2 SD9000 2.3...700 0.010...4 000 000 A): ± (3 % MV + 0.3 % VMR) / B): ± (6 % MV + 0.6 % VMR) R 2 SD2000 Common technical data Operating voltage [V] 19...30 DC Analogue output [mA] 4...20 Housing materials PBT-GF 20; PC (APEC), Makrolon; stainless steel (304/1.4301); Viton Materials (wetted parts) high-grade stainless steel 316L /1.4404; ceramics; glass passivated; PEEK (polyetheretherketone); polyester; Viton; aluminium; anodized Medium temperature [°C] 0…60 Ambient temperature [°C] 0…60 Response time [s] < 0.1 (dAP = 0) Pressure resistance [bar] 16 Protection IP65, III Connection M12 connector Short-circuit protection, pulsed • Current rating [mA] 2 x 250 Type SD Connectors and splitter boxes Type Description Order no. Socket, M12, 2 m black, PUR cable EVC004 Socket, M12, 5 m black, PUR cable EVC005 Socket, M12, 10 m black, PUR cable EVC006 Larger measuring ranges on request. Reverse polarity / overload protection • / • Application: argon (Ar), carbon dioxide (CO2), nitrogen (N2) Ar: 0.08...24.54 CO2: 0.047...14.38 N2: 0.05...14.94 0.001...1 000 000 (6% MV + 0.6% VMR) G 1/4 SD5100 Ar: 0.39...118.2 CO2: 0.24...71.7 N2: 0.24...73.0 0.001...1 000 000 (6% MV + 0.6% VMR) R 1/2 SD6100 Fluidsensorsanddiagnosticsystems Flow sensors For further technical data please go to: www.ifm.com
  32. 32. 32 Fluidsensorsanddiagnosticsystems bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition On-site control monitor for the flexible connection of flow sensors. Flow monitoring in a return pipe with a large nominal width. High flexibility Standardised M12 connections are used to connect con- trol monitor and sensor as well as the supply. This allows the use of an evaluation and display unit in different applications, e.g. for different immersion depths and a wide range of aggressive liquids. Easy handling and high functionality Adjustment to the flow and setting of the switch points are carried out by pressing a pushbutton. Flow and switch point are indicated by a multicolour LED display. High re- peatability of the switch points offers an optimum choice for use. Electronic locking of the settings and factory reset of the parameters provide additional safety. For the connection of sensors with different immersion depths. For sensors made of ceramics, high-grade stainless steel and titanium. Teach button allows easy scaling of the measuring range. Flow and switch point are indicated by LEDs directly on the unit. Available in DC and AC versions. Modular flow monitoring for field applications. product news
  33. 33. 33 11.2011 Flow sensors Fluidsensorsanddiagnosticsystems Operating voltage [V] Current consumption [mA] Protection Power-on delay time [s] Ambient temperature [°C] Order no. M12 connector · electrical design DC PNP / AC, relay 19...36 DC < 75 IP 67 10 -20...60 Switch point adjustment via pushbuttons Material stainless steel (304S15) SR5900 Accessories Type Description Order no. Protective cover, PP colourless E40203 Connectors and splitter boxes Type Description Order no. Control monitor for flow sensors of the SF series * aluminium oxide, 99.7 % Setting range liquid / gaseous [cm/s] Medium temperature [°C] Response time [s] Temperature gradient [K/min] Pressure resistance [bar] Order no. M12 connector · process connection adapter 3...300 / 200...3000 -25...80 1...10 300 300 Sensor length [mm] 44 Material stainless steel (316S12) SF5200 3...300 / 200...3000 -25...80 1...10 300 30 55 stainless steel (316S12) SF5201 M12 connector · process connection clamp adapter · with flexible immersion depth 3...300 / 200...3000 -25...80 1...10 30 30 191 stainless steel (316S12) SF6200 M12 connector · process connection G 1/4 male, G 1/2 male, adapter · for aggressive media 3...60 / - 5...70 2...20 7 30 12 ceramics* SF2405 3...60 / - 5...70 2...20 7 30 15,5 ceramics* SF3405 3...300 / 200...3000 -25...80 1...10 300 300 44 titanium (3.7035) SF5700 Sensors for connection to control monitor M12 socket, 2 m black, PUR cable EVC001 M12 socket, 5 m black, PUR cable EVC002 M12 socket, 2 m black, PUR cable EVC004 M12 socket, 5 m black, PUR cable EVC005 Wiring diagram 90...240 AC < 45 IP 67 10 -20...60 über Taster stainless steel (304S15) SR5906 L+ L 1 4 3 1 3 4 2 5 n.c. L1 N Out SR5900 SR5906 3...300 / 200...3000 -25...80 1...10 30 30 106 stainless steel (316S12) SF6201 3...300 / 200...3000 -25...80 1...10 300 300 63 titanium (3.7035) SF5701 3...300 / 200...3000 -25...80 1...10 300 300 93 titanium (3.7035) SF5702 3...300 / 200...3000 -25...80 1...10 300 300 143 titanium (3.7035) SF5703 3...300 / 200...3000 -25...80 1...10 300 300 243 titanium (3.7035) SF5704 For further technical data please go to: www.ifm.com
  34. 34. 34 PN7 pressure sensor with communication interface IO-Link 1.1. PN7 pressure sensors in hydraulic and pneumatic lines Parameter setting, diagnosis and trans- mission of process values via IO-Link. High switch point accuracy and switching frequency. Ceramic measuring cell for more than 100 million switching operations. Dual independent switching outputs or switching and diagnostic output. Different versions with pressure ranges between -1...600 bar. Pressure sensor with choice of switch points or analogue values. Fluidsensorsanddiagnosticsystems bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition PN7 pressure sensor upgraded with IO-Link IO-Link is a simple, point-to-point, communication pro- tocol between an IO-Link enabled device, such as a sen- sor or actuator, and an IO-Link master. IO-Link advantages The IO-Link circuit allows the process measurement data, parameters and diagnostic information to be transmitted using the standard connection cable. For example, the pressure measurement can be transferred as a digital value directly to the PLC. The measurement is more accurate, free from conversion errors. IO-Link masters can also store the set up parameters of their sensors. If the original sensor is damaged, then the IO-Link master will recognise its "blank" replacement and automatically download the stored set up into the newly connected sensor, saving time and avoiding errors. product news
  35. 35. 35 04.2012 M12 connector · output function 2 x NO/NC programmable or 1 x NO/NC + diagnosis 0...600 PN7060 0...400 PN7000 0...250 800 600 400 1200 1000 850 6...600 4...400 2...250 PN7001 Accessories Type Description Order no. Protective cover E30006 Adapter G 1/4 – G 1/2 E30050 Adapter G 1/4 – M20 x 1,5 E30010 Adapter G 1/4 – G 1/4 E30007 Adapter G 1/4 – 1/4" NPT E30058 Process connection G 1/4 I, PNP / NPN switching, diagnostic output Measuring range Relative pressure [bar] Order no. Poverload max. [bar] Pburst max. [bar] Set point SP1 / SP2 [bar] 3...597 2...398 1...249 0...100 PN7002 0...25 PN7003 -1...10 300 150 75 650 350 150 1...100 0.2...25 -0.90...10.00 PN7004 0.5...99.5 0.1...24.9 -0.95...9.95 Reset point rP1 / rP2 [bar] 3 2 1 0.5 0.1 0.05 0...2.5 PN7006 0...1 20 10 50 30 0.02...2.5 0.01...0.1 PN7007 0.01...2.49 0.005...0.995 0.01 0.005 Protection, class IP 67, III IP 67, III IP 67, III IP 67, III IP 65, III IP 65, III IP 65, III IP 65, III -1...1 20 50 -0.97...1 PN7009-0.98...0.99 0.01 IP 65, III Step increment [bar] Operating voltage [V DC] 18...36 Current rating [mA] 250 Current consumption [mA] < 50 Accuracy / deviation (in % of the span) turn down 1:1 Switch point accuracy Linearity error Hysteresis Repeatability Long-term stability Temperature coefficients (TEMPCO) in the temperature range 0...60 °C (in % of the span per 10 K) Greatest TEMPCO of zero Greatest TEMPCO of the span < ± 0.5 < ± 0.25 (BFSL) / < ± 0.5 (LS) < ± 0.25; PN7060: < ± 1.0 < ± 0.1 < ± 0.05 0.2 0.2 Type of pressure: relative pressure liquids and gases Common technical data Medium temperature [°C] -25...80 Housing materials stainless steel (304/1.4301), high-grade stainless steel (316L/1.4404),PC (Makrolon), PBT (Pocan), PEI, FPM (Viton) Materials in contact with the medium stainless steel (303/1.4305), ceramics, FPM (Viton) Function display switching status LED operation 2 x yellow 3 x green Communication interface IO-Link 1.1 COM2 slave; 38.4 kbaud Power-on delay time [s] 0.3 Switching frequency [Hz] ≤ 170 Shock resistance 50 g Vibration resistance 20 g Switching cycles PN700x: 100 million PN7060: 50 million Connectors and splitter boxes Short-circuit protection, pulsed • Protected against reverse polarity • Overvoltage protection up to 40 V Integrated watchdog • Voltage drop [V] < 2 IO-Link interface, current consumption from USB port E30396 Memory plug, parameter memory for IO-Link sensors E30398 Socket, M12, 2 m black, PUR cable EVC001 Socket, M12, 5 m black, PUR cable EVC002 Socket, M12, 2 m black, PUR cable EVC004 Socket, M12, 5 m black, PUR cable EVC005 Type Description Order no. Pressure sensors Fluidsensorsanddiagnosticsystems For further technical data please go to: www.ifm.com
  36. 36. 36 Flush design for hygienic applications. Pressure monitoring in hygienic areas. Flexible: 2, 3 or 4 wires The pressure sensors of the PI27/ PI28 series with clearly visible LED display can not only be connected as 3- or 4- wire units but also as 2-wire units in a current loop. This reduces the wiring complexity in new installations and facilitates exchange in existing 2-wire connections. Flush and hygienic The full-metal version of the PI pressure sensor is now also available with conical G1 process connection in addition to the Aseptoflex Vario connection available so far. It is also possible to use it for flush installation when using an adapter. It can also be used for hygienic appli- cations. This makes it easier to exchange units in existing installations. Process connection G1 Aseptoflex Vario or G1 conical. Programmable analogue output in 2-wire operation. Additional switching output in 3/4-wire operation. High overall accuracy (0.2 %) and electronic temperature compensation. High temperature resistance, therefore suitable for SIP and CIP processes. 2-wire pressure sensor with display, parameter setting via IO-Link. Fluidsensorsanddiagnosticsystems bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition product news
  37. 37. 37 11.2011 Flush pressure sensors with Aseptoflex Vario G1 process connection. Measuring range Relative pressure [bar] Order no. Poverload max. [bar] Analogue start point [bar] Analogue end point [bar] Set point SP1 [bar] Reset point rP1 [bar] Step increment [bar] Pressure sensors Fluidsensorsanddiagnosticsystems Output function switching output PNP/NPN programmable + analogue output programmable -1...25 PI2793 -1...10 PI2794 -1...4 100 50 30 -1.00...18.74 -1.0...7.5 -1.00...3.00 5.24...25.00 1.5...10.00 0.00...4.00 PI2795 Accessories Type Description Order no. Aseptoflex Vario adapter Clamp 1-1.5" for PEEK / O-ring E33201 Aseptoflex Vario adapter Clamp 1-1.5" Metal-to-metal seal E33701 G1 adapter for Clamp 1-1.5" E33601 G1 adapter for DIN11851 DN40 (1.5") E33612 Aseptoflex Vario adapter Clamp 2" for PEEK / O-ring E33202 Aseptoflex Vario adapter Clamp 2" Metal-to-metal seal E33702 FKM (Viton) sealing ring for Aseptoflex Vario adapter E30123 PEEK sealing ring for Aseptoflex Vario adapter E30124 -0.96...25.00 -0.98...10.00 -0.990...4.000 -0.124...2.5 PI2796 -0.05...1 PI2797 -0.0124...0.25 20 10 10 -0.124...1.880 -0.05...0.75 -0.0124...0.1874 0.500...2.500 0.2...1.00 0.05...0.25 PI2798 -0.120...2.500 -0.048...1.00 -0.012...0.25 -1.00...24.96 -1.00...9.98 -1.000...3.990 -0.124...2.496 -0.05...0.998 -0.0124...0.2496 -1...1 PI2799 -0.005...0.1 10 4 -1...0.5 -0.005...0.075 -0.5...1 0.02...0.1 PI2789 -0.998...1 -0.0048...0.1 -1...0.998 -0.005...0.098 0.02 0.01 0.005 0.002 0.001 0.0002 0.001 0.0001 Operating voltage [V DC] 20...32 (2W), 18...32 (3W) Current rating [mA] 250 Current consumption [mA] 3.6...21 (2W) / < 45 (3W) IO-Link Device type of transmission COM2 (38.4 kbaud) Accuracy / deviation (in % of the span) turn down 1:1 Deviation of the switch point Deviation of the characteristics Linearity Hysteresis Repeatability Long-term stability Temperature coefficients (TEMPCO) in the temperature range 0...70 °C (in % of the span per 10 K) Greatest TEMPCO of zero Greatest TEMPCO of the span PI2x9x < ± 0.2 < ± 0.2 < ± 0.15 < ± 0.15 < ± 0.1 < ± 0.1 < ± 0.05 < ± 0.15 PI2x89 < ± 0.5 < ± 0.5 < ± 0.25 < ± 0.2 < ± 0.1 < ± 0.1 < ± 0.1 < ± 0.2 Type of pressure: relative pressure Liquids and gases Common technical data Medium temperature [°C] -25...125 (145 max. 1 h) Materials (wetted parts) high-grade stainless steel 316L (1.4435); ceramics (99.9 % Al2O3); PTFE Power-on delay time [s] 1 (2W) / 0.5 (3W) Response time switching output [ms] 3 Protection IP 67 / IP 68 / IP 69KConnectors and splitter boxes Socket, M12, 4-pole 5 m orange, PVC cable EVT004 Socket, M12, 4-pole 10 m orange, PVC cable EVT005 Output function switching output PNP/NPN programmable + analogue output programmable PI2893 PI2894 PI2895 PI2896 PI2897 PI2898 PI2899 PI2889 Front flush pressure sensors with G1 process connection -1...25 -1...10 -1...4 100 50 30 -1.00...18.74 -1.0...7.5 -1.00...3.00 5.24...25.00 1.5...10.00 0.00...4.00 -0.96...25.00 -0.98...10.00 -0.990...4.000 -0.124...2.5 -0.05...1 -0.0124...0.25 20 10 10 -0.124...1.880 -0.05...0.75 -0.0124...0.1874 0.500...2.500 0.2...1.00 0.05...0.25 -0.120...2.500 -0.048...1.00 -0.012...0.25 -1.00...24.96 -1.00...9.98 -1.000...3.990 -0.124...2.496 -0.05...0.998 -0.0124...0.2496 -1...1 -0.005...0.1 10 4 -1...0.5 -0.005...0.075 -0.5...1 0.02...0.1 -0.998...1 -0.0048...0.1 -1...0.998 -0.005...0.098 0.02 0.01 0.005 0.002 0.001 0.0002 0.001 0.0001 For further technical data please go to: www.ifm.com
  38. 38. 38 Temperature transmitter with 4...20 mA and IO-Link 1.1. Increased confidence in process quality. The use of two different sensor elements which monitor each other in the process ensures that a developing sen- sor drift is immediately detected and reliably diagnosed. Furthermore, if one element fails, the process continues with the second measuring element (backup function). Application As an extension to the applications, the tried-and-tested and self-monitoring TAD temperature sensors are com- plemented by another probe length (50 mm). IO-Link With IO-Link 1.1 the sensors are of state-of-the-art tech- nology. Fluidsensorsanddiagnosticsystems bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition Integrated drift monitoring, diagnostic and backup function. Including 5-point calibration certificate. Precision of 0.2 K at -10...100 °C otherwise 0.3 K. Increased process safety due to self-monitoring. Cost savings possible through reduced calibration intervals. Reliable, self-monitoring temperature measurement. product news
  39. 39. 39 04.2012 Accessories Type Description Order no. Other technical data Measuring range [°C] -25...150 / 160 max. 1h Accuracy Process value, drift monitoring (-10...100 °C) [°C] (-25...-10 / 100...150 °C) [°C] ± 0.2 ± 0.3 Materials (wetted parts) high-grade stainless steel (316S12) Surface characteristics Ra: < 0.6 Connection M12 connector, gold-plated contacts Perm. overload pressure [bar] 50 Self-monitoring temperature sensor for liquids and gases Connectors and splitter boxes Type Description Order no. M12 socket, 5 m orange, PVC cable EVT001 M12 socket, 10 m orange, PVC cable EVT002 M12 socket, 5 m orange, PVC cable EVT004 M12 socket, 10 m orange, PVC cable EVT005 Resolution [°C] < 0.05 Measuring element Pt1000 / NTC, thermically coupled Electrical design Order no. Process connection Rod length [mm] Response time T05 / T09 [s] Programming interface TAD transmitters 4…20 mA · 2-wire or 3-wire operating 4...20 mA (scalable) 4...20 mA (scalable) Operating voltage [V DC] 4...20 mA (scalable) 4...20 mA (scalable) Programming options: Threshold for drift warning / alarm; fail-safe; display unit; scaling of the analogue output; redundancy switching; performance diagnostic output; output logic; normally open / normally closed Adapter G 1/2 female – clamp 1"–1.5" E33401 Adapter G 1/2 female – clamp 2" E33402 Welding adapter ball, G 1/2 E30055 Welding adapter collar, G 1/2 E30056 Temperature sensors Fluidsensorsanddiagnosticsystems * other Aseptoflex Vario adapters available TAD981Aseptoflex Vario 33 15...32 IO-Link 1.1 TAD081Aseptoflex Vario 50 15...32 IO-Link 1.1 G 1/2 male 33 15...32 IO-Link 1.1 TAD091G 1/2 male 50 3 / 6 3 / 6 3 / 6 3 / 6 15...32 IO-Link 1.1 Wiring 2 L+ L 1 L+ L 3 BU 4 BK 2 WH 1 BN 2 WH 1 BN TAD: 1) 2-wire operation, 2) 3-wire operation Protection IP 68 / IP 69K Aseptoflex Vario welding adapter* Ø 50 mm E30122 Sealing by O-ring Aseptoflex Vario adapter* Clamp 2", ISO 2852 E33702 Metal-to-metal seal Aseptoflex Vario adapter* Varivent type N, DN40 (1.5"), Ø 68 mm E33722 Metal-to-metal seal Aseptoflex Vario adapter* pipe fitting, DN40 (1.5"), DIN 11851 E33712 Metal-to-metal seal TAD1814...20 mA (scalable) Aseptoflex Vario 87.5 15...32 IO-Link 1.13 / 6 4...20 mA (scalable) G 1/2 male 87.5 3 / 6 15...32 IO-Link 1.1 TAD191 TAD991 For further technical data please go to: www.ifm.com
  40. 40. 40 New Pt100 sensors for industrial applications. Probe sensor with connected TR control monitor. Long lasting precision The probe sensors ensure very precise temperature measurement using a Pt100 element of precision class A. The high protection ratings IP 68 / IP 69K and the high- grade stainless steel housing guarantee long life of the sensors. Even faster response times Using the latest technologies and a very thin sensor tip, the response time is extremely fast. A wide range of applications These new sensors complete the existing product range and can be used in many application solutions. Fast response times of T05 = 1 s and T09 = 3 s. Probe diameter of 6 mm or 8.2 mm for TM9900 (titanium measuring probe). Robust stainless steel housing with IP 68 and IP 69K protection ratings. High pressure resistance for different application areas. Precise temperature measurement using a Pt100 sensor element, class A. For fast temperature changes. Fluidsensorsanddiagnosticsystems bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition product news
  41. 41. 41 11.2011 Control monitor Description Order no. Control monitor, 1 x analogue output, 1 x PNP/NPN TR2432 Control monitor, 2 x PNP/NPN TR7432 Measured signal converter, Pt100 / Pt1000 in 4...20 mA, scaling 0...100 °C TP3237 Connectors and splitter boxes Type Description Order no. Socket, M12, 2 m black, PUR cable EVC004 Socket, M12, 5 m black, PUR cable EVC005 M12 jumper 2 m black, PUR cable EVC013 M12 jumper 5 m black, PUR cable EVC014 Accessories Type Description Order no. Mounting set, connection of TT sensors to TR, stainless steel (303 / 1.4305) E30017 Clamp fitting G 1/2, 6/8/10 mm, stainless steel (303 / 1.4305), FPM (Viton) E30018 Clamp fitting 1/2" NPT, 6/8/10 mm, stainless steel (303 / 1.4305); FPM (Viton) E30025 Progressive ring fitting G 1/2, 6 mm, high- grade stainless steel (316Ti / 1.4571) E30047 Progressive ring fitting 1/2" NPT, 6 mm, high-grade stainless steel (316Ti / 1.4571) E30049 Progressive ring fitting G 1/4, 6 mm, high- grade stainless steel (316Ti / 1.4571) E33431 Welding adapter, 24.7 mm, clamp adapter, high-grade stainless steel (316L / 1.4404) E30108 Adapter G 1/2 for TM9900, Titanium E40114 Adapter G 1/4 for TM9900, Titanium E40115 Nominal pressure [bar] (The fitting used determines the permissible operating pressure.) 160 / (TM4101 250) 300 Protection IP 68 / IP 69K Material high-grade stainless steel (316L/ 1.4404) titanium Dynamic response time T05 / T90 [s] 1 / 3 Measuring range [°C] -40...150 -40...125 Precision [%] ± (0.15 K + 0.002 x ItI) ± (0.3 K + 0.005 x ItI) Measuring element Pt100 to DIN EN 60571 Class A Class B Technical dataProbe sensors TT Type Nominal length L [mm] Order no. Pt100, 6 mm Probe sensors TM4 Type Nominal length L [mm] Order no. TM441150 TM4431100 TM4441150 TM4461250 Pt100, 6 mm, G 1/2 TM431150 TM4331100 TM4341150 TM4361250 Pt100, 6 mm, 1/2" NPT TT928150 TT0281100 TT1281150 TT2281250 TT3281350 Probe sensor titanium M18 x 1.5 Type Nominal length L [mm] Order no. Pt100, 8.2 mm, M18 x 1.5 TM990044 TM, TT TM9900 Temperature sensors Fluidsensorsanddiagnosticsystems TM410125 Pt100, 6 mm, G 1/4 For further technical data please go to: www.ifm.com
  42. 42. 42 Hygienic Pt100 sensors with 4-wire connection. Temperature measurement in beverage tanks. Process connection The TM45 series is equipped with a hygienic G1/2 thread. The TM48 and TM49 versions are fitted with an integra- ted 1...1.5" or 2" clamp process connection. The TTx291 probe is fixed using clamp fittings. Fast response time The 6 mm thin sensor tip guarantees an excellent re- sponse time of T05 = 1 s and T09 = 3 s while ensuring high stability. For hygienic areas The sensor is perfectly fitted for use in hygienic applica- tions thanks to its high protection rating of IP 68 / IP 69 K and high surface definition. As probe sensor or with integrated Tri-Clamp process connection. Probe diameter 6 mm. Robust stainless steel housing with IP 68 and IP 69K protection ratings. High pressure resistance for different application areas. Precise temperature measurement using a Pt100 sensor element, class A. New additions to the temperature probe range. Fluidsensorsanddiagnosticsystems bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition product news
  43. 43. 43 11.2011 Control monitor Description Order no. Control monitor, 1 x analogue output, 1 x PNP/NPN TR2432 Control monitor, 2 x PNP/NPN TR7432 Measured signal converter, Pt100 / Pt1000 in 4...20 mA, scaling 0...100 °C TP3237 Connectors and splitter boxes Type Description Order no. Socket, M12, 2 m orange PVC cable EVT067 Socket, M12, 5 m orange PVC cable EVT004 M12 jumper, 2 m orange, PVC cable EVT043 M12 jumper, 5 m orange, PVC cable EVT044 Accessories Type Description Order no. Mounting set, connection of TT sensors to TR, stainless steel (303 / 1.4305) E30017 Welding adapter, 24.7 mm, clamp fitting, PEEK sealing E30407 Nominal pressure [bar] (The fitting used determines the permissible operating pressure.) 160 Protection IP 68 / IP 69K Material high-grade stainless steel (316L/1.4404) Dynamic response time T05 / T90 [s] 1 / 3 Measuring range [°C] -40...150 Precision [%] ± (0.15 K + 0.002 x ItI) Measuring element Pt100 to DIN EN 60571 Class A Common technical dataSensors with process connection Type Nominal length L [mm] Order no. TM480130 TM481150 TM4831100 TM4841150 Pt100, 6 mm, Clamp 1...1.5" TM490130 TM491150 TM4931100 TM4941150 Pt100, 6 mm, Clamp 2" Probe sensors Type Nominal length L [mm] Order no. TT929150 TT0291100 TT1291150 TT2291250 TT3291350 Pt100, 6 mm Temperature sensors Fluidsensorsanddiagnosticsystems TM459120 TM450130 TM451150 TM4531100 TM4541150 Pt100, 6 mm, G 1/2 Welding adapter, cylindrical, G 1/2 E43300 Welding adapter, cylindrical for pipes, G 1/2 E43301 Adapter G 1/2 I – DIN 11851 DN25 E43304 Adapter G 1/2 I – DIN 11851 DN40 E43305 For further technical data please go to: www.ifm.com
  44. 44. 44 Type TP: Modular transmitter – great benefit. Minimised installation and error sources. Because of the use of two standardised M12 connec- tions, the installation complexity of the TP temperature plug is reduced to a minimum as compared to a common head / DIN rail transmitter. Furthermore, error sources such as cable clamps are eliminated. Versatile use. Thanks to 4-wire Pt100 / Pt1000 evaluation, the trans- mitter can also be connected to a Pt element using con- nection cables. Due to its small size, it is also suited for harsh applications, because it can be installed in a safe position. In addition the scalability of the TP between -50...300 °C, using the USB interface E30396 allows individual adapta- tion of the measuring range to almost any application. Small, light housing with M12 connections. Reduced mounting complexity and error sources. Scalable Pt100 / Pt1000 evaluation from -50...300 °C. Status LED signals the operating status. Full potting and ecolink M12 technology guarantee high vibration resistance. Head transmitter – a thing of the past. Temperature plug – the future. Fluidsensorsanddiagnosticsystems bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition product news
  45. 45. 45 11.2011 Factory setting measuring range (Measuring range scalable) Order no. M12 connections · output function 4...20 mA / IO-link 1.0 Sockets (extract) Type Description Order no. Socket, M12, 2 m orange, PVC cable EVT067 Socket, M12, 5 m orange, PVC cable EVT004 Socket, M12, 2 m black, PUR cable EVC004 Socket, M12, 5 m black, PUR cable EVC005 Operating voltage [V DC] 20...32 Ambient temperature [°C] -25...70 Max. measuring range (4...20 mA) [°C] -50...300 4-wire evaluation Pt100 and Pt1000 • Housing material PA PACM 12 (TROGAMID); PET; seal: FPM (Viton) Material coupling nut high-grade stainless steel (1.44.04) Protection IP 67, III Accuracy via: IO-Link Analogue output ± 0.3 K ± 0.3 K + (± 0.1 %) of the scaled span Temperature coefficient (in % of the span per 10 K) < 0.1 % Common technical data TP temperature plug Connection cables (extract) Type Description Order no. Connection cable, M12, 2 m orange, PVC cable EVT043 Connection cable, M12, 5 m orange, PVC cable EVT050 Connection cable, M12, 2 m black, PUR cable EVC013 Connection cable, M12, 5 m black, PUR cable EVC034 USB IO-Link interface E30396 Accessories Type Description Order no. Temperature sensors Fluidsensorsanddiagnosticsystems Vibration resistance 20 g Dimensions Wiring diagram 1) Connection for voltage supply and output signals 2) Connection for temperature sensor 18M12x1 M12x1 25 LED 22 52 2 1) Two-wire sensor 2) Four-wire sensor 3) Operation as 2-wire temperature transmitter 4) Operation as 3-wire unit, IO-Link communication possible B) Link TP3232 TP3237 -50...300 °C 0...100 °C TP3231-50...150 °C TP32330...300 °F M12 connections · output function 0...10 V / IO-link 1.1 TP92370...100 °C 4 1 3 2 L+ L IO-Link 1 2 3 4 1 2 1 2 3 4 B B TP 4 1 3 2 L+ L L IO-Link1 2 3 4 1 2 3 4 1 2 3 4 B B TP TP9237 TP3232, TP3237, TP3231, TP3233 For further technical data please go to: www.ifm.com
  46. 46. 46 Diagnostic electronics with fast reaction time, detects machine crash < 1 ms. Crash monitoring of machine tool spindle. Machine monitoring The diagnostic electronics type VSE offers a range of functions for early detection of damage and machine protection. Examples are detection of unbalance, moni- toring of overall vibration and bearing condition as well as trend analysis with integrated history function and condition counters. This increases machine availability, secures quality and makes maintenance planable. Machine protection An important aspect of machine monitoring is permanent machine protection. This avoids costly subsequential dam- ages and reduces maintenance costs. Additional process monitoring avoids waste and increases efficiency. An additional software is available for the simple inte- gration into Linux and Windows based PLCs. Variable switching levels for process monitoring. Progammable switching times and alarm reactions. Detects unbalance and damage to rolling element bearings. Protects machines from permanent overload. Records all relevant data with real-time stamp. The Fast One. Fluidsensorsanddiagnosticsystems bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition product news
  47. 47. 47 11.2011 Technical data Voltage supply [V] 24 DC ± 20 % Protection IP 20, III Ambient temperature [°C] 0...70 Housing DIN rail 2 inch Diagnostic electronics VSE100 Dimensions 50 114 LEDs 2 1 105 35,5 Diagnostic electronics for vibration sensors type VSA Wiring diagram L+ (24 V DC ±20 %) 18 17 20 19 14 13 16 15 22 21 24 23 6 5 8 7 2 1 4 3 10 9 12 11 L- OU 1: switch/analog OU 2: switch IN 1 (0/4...20 mA / pulse) GND 1 IN 2 (0/4...20 mA / pulse) GND 2 1 2 3 4 BN WH BU BK 4 3 2 1 BK BU WH BN I/O 7 30 29 32 31 34 33 36 35 26 25 28 27 43 44 41 42 47 48 45 46 39 40 37 38 GND I/O 8 GND I/O 5 GND I/O 6 GND I/O 1 GND I/O 2 GND I/O 3 GND I/O 4 GND U-OUT (0...10 V) GND U-IN 1 (0...10 V) GND 1 U-IN 2 (0...10 V) GND 2 1 2 3 4 BN WH BU BK 1 2 3 4 BN WH BU BK Data interface Ethernet TCP/IP, (10 / 100 Mbits) History memory integrated 1) Ethernet interface 2) Combicon connector with screw terminals (option) Accessories (to be ordered separately) Type Description Order no. Parameter software version 2.6 or higher VES003 octavis OPC server software German / English VOS001 Ethernet, cross-over patch cable 2 m EC2080 Inputs 4 sensor inputs 0...10 mA 2 rotational speed inputs (0/4...20 mA or 0...10 V or pulse 24 V) 8 x digital inputs/outputs (freely configurable) (PNP 100 mA) Outputs 2 x digital alarm outputs (PNP 100 mA) or: 1 x digital alarm output + 1 x analogue output 0/4...20 mA / 0...10 V 8 x digital inputs/outputs (freely configurable) (PNP 100 mA) Order no. Vibration sensors For connection to diagnostic electronics type VSE VSA001 Measurement range ± 25 g; IP 69K; frequency range 0...6.000 Hz; connection: M12 connector VSA002 Measurement range ± 25 g; IP 67; frequency range 0...10.000 Hz; connection: PUR cable with connecter M12, 0.6 m VSA004 Measurement range ± 25 g; IP 67; frequency range 0...10.000 Hz; connection: PUR cable, 3 m VSA005 Measurement range ± 25 g; IP 67; frequency range 0...10.000 Hz; connection: PUR cable, 10 m Type Description Fluidsensorsanddiagnosticsystems Diagnostic systems For further technical data please go to: www.ifm.com
  48. 48. 48 Redundant pulse evaluation system for safe standstill monitoring. Operating principle The standstill monitor is a pulse evaluation system for safe detection of underspeed or standstill. It receives the pulses from the pulse pick-ups connected on the inputs. The μPs calculate the pulse sequence time and the re- sulting frequency according to the principle of interval measurement. By continuously comparing the input fre- quency (actual value) and the switch point (preset value) the evaluation system promptly detects standstill and the output relays switch according to the preset switching function. Switching function In accordance with "safe" standstill signalling, the relays are energised when the event occurs. The relays switch when the actual value falls below the activated preset value by e.g. 5 %. The NO contacts of the relays are connected in "series" and connected to the terminals. Evaluationsystems,powersupplies Rotational speed detection by 2 sensors. Redundant structure of the hardware. Redundant evaluation of the pulse sequences. Relay with positively-driven contacts. 4 switch points selectable. Standstill safely detected! bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition product news
  49. 49. 49 11.2011 Applications: Monitoring rotational or linear movements for minimum switch point not reached (standstill). Evaluationsystems,powersupplies Evaluation systems Operating voltage [V] 24 DC (19.2...30 DC); incl. 5 % residual ripple Sensor supply [V] 24 DC / ≤ 50 mA Input frequency, max. [Hz] ≤ 3500 Current consumption [mA] ≤ 200 Switch points [Hz] 0.2 / 0.5 / 1.0 / 2.0 Input data Pulse inputs S34, S43: Input voltage: "1": ≥ 11 V, ≤ 10 mA "0": ≤ 5 V, ≤ 2 mA ≤ 36 V Output function 2 safety-related switching outputs (floating contacts); 1 fault output (positive switching) Contact rating 6 A, 250 V AC / 24 V DC Ambient temperature [°C] -25...55 Function display Voltage LED Fault LED Switching status LED Input signal LED green red 2 x yellow 2 x yellow Protection IP 20, II Housing materials PA (polyamide) Safety-related reliability PFHd [1/h] 3.38 x 10-9 Test interval T1 [years] 0.5 MTTFd [years] > 100 DC/CCF/Cat. 99 % / complied with / 4 Standstill monitor DA101S Dimensions 25 100 LED 35,5 105 1) Combicon connector with screw terminals 2) DIN rail mounting Technical dataSafety If during operation a mechanical or electrical error cau- ses one sensor to fail, there will be an interruption of the pulse sequence. In accordance with "safe" stand- still monitoring this is not considered as underspeed. The relays do not switch. Sensor monitoring: The function and the behaviour of the sensors are moni- tored dynamically and subjected to a plausibility check. • By permanently comparing the pulses it is evaluated whether the pulse sequences of both sensors differ from each other (f1 ≠ f2). • The arrangement of the mark-to-space ratio of the damping cams and gaps ensures that at no time are both sensors undamped but at least one sensor is always damped. • Switch points: Via an external circuit a switch point from among 4 preset values (2 Hz, 1 Hz, 0.5 Hz and 0.2 Hz) can be selected. • Feedback contact: The device monitors the position of an interlock by means of a feedback contact. When a movement starts, the output relays K1/K2 are de-energised. The switching outputs open. The output LEDs K1/ K2 flash when the feedback contact is open. • Error message: If faults such as described for "sensor monitoring" are detected by the μPs, the relays are kept in the "safe status" (no standstill message), the LED "Fault" lights and the output switches (opens). ≥5xD D D 3xD Meets the requirements of: ISO 13849-1: Category 4 ISO 13849-1: PL e EN 62061: SIL 3 For further technical data please go to: www.ifm.com
  50. 50. 50 ecolink – a new dimension in connection technology. For hygienic and wet areas in the food industry. ecolink M12 for demanding applications. Most applications require special solutions. Only high- quality materials, safe production processes and fault- less mounting lead to success in the long run. The integrated end stop protects the O-ring against destruction caused by tightening the nut too much. Mounting and removal are carried out without tools. The asymmetrically acting vibration protection holds the nut tight in its position, guaranteeing an optimum and permanent seal. High-quality materials especially adapted to the applica- tion and intensive monitoring during and after produc- tion guarantee maximum quality standards. Connectiontechnology bus, identification and control systems position sensors and object recognition fluid sensors and diagnostic systems Connection technology meets the M12 standard (EN 61076). Optimum sealing even when mounted without tools. The mechanical end stop protects the O-ring against destruction. Nut secured against shock/vibration due to saw tooth contoured vibration protection. LEDs clearly visible even in cases of high light exposure. ecolink M12 – the secure connection even in difficult applications. product news
  51. 51. 51 04.2012 Technical data Operating voltage: without LED: 60 V AC / 60 V DC with LED: 10...36 V DC Nominal current: 4 A Protection rating: IP 67, IP 68, IP 69K in locked condition with the matching counterpart. Tightening torque of the plug: 0.6...1.5 Nm (Take into account the max. value of the counterpart!) Tightening torque of the socket: 0.6...1.5 Nm Ambient temperature: -25...100 °C (cURus max. 50 °C) Vibration / shock: 750 g, 1 million cycles Materials: Housing / moulded body: without LED, PVC orange with LED, PVC black Contact carrier: PA 6.6 Coupling nut: high-grade stainless steel (316S12) Contacts: gold-plated Sealing ring: EPDM Cable: PVC, 4 x 0.34 mm2, Ø 4.9 mm 3 x 0.34 mm2, Ø 4.9 mm with LED Approvals: cURus in preparation Connectiontechnology Connection technology Applications: Hygienic and wet areas in the food industry (food and beverage) Type Description Order no. Dimensions L50 17 M12x1 15 15,5 45 14 M12x1 14 B A C Example EVT329 L50 17 M12x1 15 36,5 15,5 26,5 14 M12x1 14 B A C Example EVT332 L50 17 M12x1 15 36,5 15,5 26,5 14 M12x1 14 LEDB A C Example EVT335 1.0 m 2.0 m 5.0 m 1.0 m 2.0 m 5.0 m 1.0 m, LED 2.0 m, LED 5.0 m, LED EVT329 EVT330 EVT331 EVT335 EVT336 EVT337 EVT332 EVT333 EVT334 Y connection cable M12 For further technical data please go to: www.ifm.com
  52. 52. 52 ecolink – a new dimension in connection technology. From factory automation to machine tool industry. ecolink M12 for demanding applications. Most applications require special solutions. Only high- quality materials, safe production processes and fault- less mounting lead to success in the long run. The integrated end stop protects the O-ring against destruction caused by tightening the nut too much. Mounting and removal are carried out without tools. The asymmetrically acting vibration protection holds the nut tight in its position, guaranteeing an optimum and permanent seal. High-quality materials especially adapted to the applica- tion and intensive monitoring during and after produc- tion guarantee maximum quality standards. Connectiontechnology bus, identification and control systems position sensors and object recognition fluid sensors and diagnostic systems Connection technology meets the M12 standard (EN 61076). Optimum sealing even when mounted without tools. The mechanical end stop protects the O-ring against destruction. Nut secured against shock/vibration due to saw tooth contoured vibration protection. LEDs clearly visible even in cases of high light exposure. ecolink M12 – the secure connection even in difficult applications. product news
  53. 53. 53 04.2012 Technical data Operating voltage: without LED: 60 V AC / 60 V DC with LED: 10...36 V DC Nominal current: 4 A Protection rating: IP 67, IP 68, IP 69K in locked condition with the matching counterpart. Tightening torque of the plug: 0.6...1.5 Nm (Take into account the max. value of the counterpart!) Tightening torque of the socket: 0.6...1.5 Nm Ambient temperature: -25...90 °C (cURus max. 50 °C) Vibration / shock: 750 g, 1 million cycles Cable characteristics: Bending cycles: > 5 million Torsional strain: ± 180°/m Materials: Housing / moulded body: without LED, TPU orange with LED, TPU black Contact carrier: TPU Coupling nut: CuZn/Ni Contacts: gold-plated Sealing ring: Viton Cable: PUR, halogen-free, 4 x 0.34 mm2, Ø 4.9 mm 3 x 0.34 mm2, Ø 4.9 mm with LED Approvals: cURus in preparation Connectiontechnology Connection technology Applications: Factory automation, machine tool industry, construction of machinery, hydraulics Type Description Order no. NEW Order no. old Dimensions Example EVC431 Example EVC434 Example EVC437 Y connection cable M12 1.0 m EVC431 2.0 m EVC432 5.0 m EVC433 E11762 E11763 – 1.0 m EVC434 2.0 m EVC435 5.0 m EVC436 E11760 E11761 – 1.0 m, LED EVC437 2.0 m, LED EVC438 5.0 m, LED EVC439 E70063 E70065 – L50 17 M12x1 15 14 45 15,5 M12x1 14 B A C 4,2 L50 17 M12x1 15 14 36,5 26,5 14 15,5 M12x1 B A C 4,2 L50 17 M12x1 15 14 36,5 26,5 14 15,5 M12x1 LEDB A C 4,2 For further technical data please go to: www.ifm.com
  54. 54. 54 AS-i gateways with ultra short transfer times. The bus at a glance The new ifm gateways are the fast connection from AS-i to Profibus or Profinet. Thanks to a colour display and web interface, the status of all AS-i slaves is recognizable at a single glance. The quick set-up menu and intuitive handling facilitate installation and diagnosis. In addition, the web interface allows full remote access. Three types of voltage supply The flexible voltage supply ensures a low-cost integration into your application. The units can be operated via AS-i power supplies, DC power supplies, or a combination of both. It is also allowed to supply several AS-i networks via a single power supply. Colour display for clear diagnosis and set-up. AS-i double address recognition. Earth fault monitor. Profinet switch with 2 ports and certifica- tion according to Conformance Class B. Profibus DP interface with certified DPV0 and DPV1 functionality. Third-generation communicator. Bussystems bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition product news
  55. 55. 55 04.2012 The products Description Order no. AS-i Profinet gateway 1 AS-i master with M4 profile AC1401 AS-i Profinet gateway 2 AS-i masters with M4 profile AC1402 AS-i data decoupling, can be mounted on AS-i Profinet gateway AC1250 Functions • Pluggable data decoupling Via the optional data decoupling AC1250, the gateway and the connected AS-i slaves can be powered by one power supply. A single voltage source can hereby supply several gateways and their AS-i networks. Power supplies with a voltage of 30 V (DC or AS-i) allow any possible AS-i structure at full cable length. The use of a 24 V power supply offers the advantage of AS-i power24: For AS-i networks of up to 50 m the introduction of the bus system AS-interface will become even more cost-efficient. • Transfer of AS-i data PLC user programs of existing plant can be changed to the new AS-i gateways of the third generation without any changes to the I/O addresses. Advantages and customer benefits Communication interfaces: Profinet: Profinet Class B Profinet switch 2 ports integrated Profibus: Profibus DPV0 and DPV1 functionality AS-Interface: 1 and 2 AS-i masters pursuant to M4 profile Configuration interface: Ethernet with integrated web interface Connections: AS-i and auxiliary supply: plug-in terminals (supplied with the unit) Profinet 2 x RJ45 Profibus D-Sub 9 Configuration interface RJ45 Visualisation: 1.8" colour display LEDs for unit and fieldbus status Housing: Robust metal housing: aluminium powder-coated; steel sheet galvanised Ambient temperature: Operating temperature 0...60 °C Storage temperature -20...70 °C Bussystems Bus system AS-interface AS-i Profibus gateway 1 AS-i master with M4 profile AC1411 AS-i Profibus gateway 2 AS-i masters with M4 profile AC1412 Dimensions 106,293 135,5 128,2 AC1401 / AC1402 128,2 45 62,8 65,5 AC1250 106,293 135,5 128,2 AC1411 / AC1412 1) Sub-D (9 poles) For further technical data please go to: www.ifm.com
  56. 56. 56 System overview with safety-related components. host (PLC) standard module standard PLC standard AS-i master I3 I1 I2 I4 safety monitor safe input module e-stop standard switch AS-i safety monitor allows parameter setting via USB interface. Introduction The new AS-i safety monitor processes up to four safe inputs or eight standard inputs /outputs locally and up to 31 safe slaves in the AS-i system. The AS-i safety monitor is equipped with a USB interface and a chip card for an easy exchange of units. The user-friendly configuration and diagnostic software ASIMON V3.0 G2 enables clear and quick assignment and logical combination of the safety-related bus com- ponents in the tried-and-tested function block represen- tation under Windows. 4 safe inputs or 8 standard inputs/outputs locally. 2 safe electronic outputs locally, 6 triggerable outputs in the field. USB 2.0 interface for clear configuration and diagnosis using the PC. Saving of data on chip card for an easy exchange of units. Certification to EN 62061/ SIL3, IEC 61508 / SIL3 and EN ISO13849-1/PLe. AS-i safety made easy. Safety at Work Bussystems bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition product news
  57. 57. 57 11.2011 The products Description Order no. Functions The AS-i safety monitor controls, in the AS-i network, the code sequences which are to be transmitted. In the case of message deviations or timeouts it ensures the safe state of the system. The unit has two safe semi-con- ductor outputs. It is possible to trigger up to six further safe outputs independently in the field. The AS-i safety monitor can be integrated into the AS-i system at any position. Several AS-i safety monitors can be operated via one AS-i master. So grouping is possible to evaluate the safe AS-i slaves without problem. Known safety relay functions like "e-stop", "stop cat- egories 0 or 1", "two-hand operation", "enable switch" can be implemented via the software. One AS-i safety monitor thus replaces many traditional safety relays. Advantages and customer benefits Due to the extension of Safety at Work safe and non safe I/O signals can be transmitted via the same AS-i bus. The safety-related extension is fully downward compatible and can be retrofitted on existing installa- tions. All masters, power supplies and bus components can still be used. Application There is a wide range of applications for the new genera- tion of the AS-i Safety at Work safety monitors. Wherever a decentralised safety technology is important, AS-i safety monitors can be used. In conveying, special machines, handling and the food industry these safety-related as- semblies have established themselves. Operating voltage [V DC] 24 AS-i interface 1 Semi-conductor outputs 2 Current rating per output [A] 0.5 Service button • AS-i profile S-7.5.5 Ambient temperature [°C] 0...55 Protection IP 20 Connection Combicon screw terminals Dimensions (H x W x D) [mm] 99 x 22.5 x 114 Stop category to EN 60204-1 0/1 Technical data Accessories Type Description Order no. Parameter setting software ASIMON V3 G2 for safety monitor E7050S USB interface cable for the connection of the safety monitor to PC E7051S Chip card to save the configuration data E7052S AS-i safety monitor, 2 channels, with semi-conductor outputs AC041S Bussystems Bus system AS-interface E7053S Safe contact extension, 2 independent channels, without delay, for AS-i safety monitor with semi-conductor outputs For further technical data please go to: www.ifm.com
  58. 58. 58 Flexible RFID system with evaluation unit, antennas and transponders. The new RFID evaluation unit with integrated Profi- bus-DP interface and web server can be used in produc- tion to mark tools, for quality assurance such as monitor- ing production steps, in conveying and in automation technology. Easy to use – flexible parameter setting – you can solve any identification task. The antenna concept guarantees easy and fast con- nection of the LF and HF RFID antennas to the evalu- ation unit by means of M12 connectors from 0.3...20 m from ifm electronic. The production range of the transponders includes not only LF transponders with up to 2 Kbit-memory but also HF transponders with 16 Kbits as FRAM version which can be rewritten an unlimited number of times. RFID evaluation unit with Profibus-DP and web server. Evaluation unit with 4 antenna connections or digital I /Os. Read/write antennas in industrially compatible housing. Antennas and transponders from a few bits to Kbytes. Protection rating IP 67 meets the require- ments for harsh environments. RFID with Profibus-DP for production and conveying. bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition Identificationsystems product news
  59. 59. 59 11.2011 Applications The new ifm RFID system platform can be used in pro- duction for quality assurance such as for electronic route cards, in assembly/handling technology for the automo- tive industry and in conveying. The RFID system is optimised for applications in • production control • asset management • material flow control • track&trace All connections have industrial-compatible M12 connec- tions. Current is supplied directly via an M12 connection. The fast and easy integration into the higher-level auto- mation/process control is effected by means of provided program examples. Complex identification tasks are as easy to implement as reading a simple UID. As an option the RFID antenna inputs can also be used for controlling outputs or detecting input signals. The ifm standard configuration ensures that no complex wiring is necessary. The connected sensors/actuators are supplied directly from the RFID evaluation unit. The RFID system features a robust housing in the high protection rating IP 67 and a broad temperature range thus meeting the requirements of harsh industrial envi- ronments. The comprehensive accessories such as Profibus connec- tion cables and terminating resistors further facilitate the system set-up. Technical data RFID evaluation unit DTE100 Operating voltage [V] 18...30 DC Current rating outputs [mA] (IO-1, IO-2) 500 (IO-3, IO-4) 1000 Current consumption AUX [mA] < 0.2 A closed circuit current consumption; < 3.0 A at max. load on IO-1 to IO-4 Ambient temperature [°C] -20...60 Protection IP 67 Material metal housing with plastic cover Switching inputs at option 4 Switching outputs at option 4 Frequency range for ANT512 [KHz] 125 Frequency range for ANT513 [MHz] 13.56 Air interface ANT513 ISO 15693 Range [mm] 60, tag dependent Indicators LED red / green / yellow Antenna concept, external 4 Antenna terminal, external M12, 20 m unscreened Description Order no. DTE100 RFID evaluation unit, Profibus-DP EU/ETSI ANT512RFID antenna 125 KHz ANT513RFID antenna 13.56 MHz E80360ID tag/30X2.5/05 – 125 KHz 256 bits E80361ID tag/30X2.5/05 – 125 KHz 2048 bits E80370 ID tag/30X2.8/03–13.56 MHz 16 Kbits – FRAM E80371ID tag/30X2.5/06 – 13.56 MHz 896 bits RFID evaluation unit RFID antennas The products RFID transponders for ANT512 RFID transponders for ANT513 Connectors and splitter boxes Type Description Order no. M12 jumper 1 m, black, PUR cable EVC012 M12 jumper 5 m, black, PUR cable EVC059 Ethernet, cross-over patch cable, 2 m, PUR cable, M12 / RJ45 E11898 Ethernet, screened patch cable, 2 m, PUR cable, M12 / RJ45 E12090 RF-identification systems Identificationsystems Zubehör Description Order no. Profibus terminating resistor, M12 connector, 4 poles, B coding E12315 PROFIBUS cable: straight M12 connector to straight M12 socket, connection cable, 10 m E12317 PROFIBUS cable: M12 connector to free cable end, straight connector, 10 m E12319 PROFIBUS cable: M12 connector to free cable end, straight socket, 10 m E12321 Further cable lengths on request For further technical data please go to: www.ifm.com
  60. 60. 60 7.0" TFT colour display with a resolution of 800 x 480 pixels. PDM360 NG dialogue module In almost any mobile machinery a powerful process and dialogue unit is needed for machine operation and for indication of system messages. With its high-resolution graphic display, the powerful 32-bit controller and the flexible programming according to IEC 61131-3, the PDM360 NG is such a user interface. Its robust housing with protection rating IP 67 enables mounting inside or outside the cabin. It has been designed for surface and panel mounting. Up to four CAN interfaces, Ethernet and USB together with the Linux operating system form a universal plat- form for networking and communication with other vehicle components. Backlit function keys with tactile feedback. Optional encoder with pushbutton or scroll key. Internal mass storage, USB interface, interfaces for analogue cameras. Up to 4 CAN interfaces with CANopen and SAE J1939 protocol. Programmable to IEC 61131-3 with CoDeSys 2.3. Dialogue module PDM360 NG for mobile vehicles. Controlsystems bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition product news
  61. 61. 61 04.2012 Description Order no. Dialogue module PDM360 NG with encoder CR1080 Dialogue module PDM360 NG with rocker switch CR1081 Mounting frame for panel mounting EC2110 USB adapter cable, M12 / RJ45 socket, 1.5 m EC2099 Ethernet, cross-over patch cable, 2 m, PUR cable, M12 connector / RJ45 connector E11898 Socket, M12, 2 m black, PUR cable EVC001 Socket, M12, 5 m black, PUR cable EVC002 Programming software CoDeSys, German version CP9006 Programming software CoDeSys, English version CP9008 Technical data Dialogue modules PDM360 NG CR1080, CR1081, CR1083 Products Housing closed, diecast aluminium Device connection 1 x M12 connector 6 x M12 socket Protection IP 65, IP 67 Operating voltage [V DC] 10...32 Functions and advantages • High-resolution display Protected by a scratch-resistant glass pane, the modern display, which can even be read in sunlight, provides a resolution of 800 x 480 pixels with an aspect ratio of 15:9. Images and graphics can be shown with a colour depth of up to 18 bits. • Mechanical structure The PDM360 NG has a fully sealed diecast aluminium housing with protection rating IP 67. The integrated M12 connectors provide all important connections for supply, inputs /outputs and communication. It can be used as surface mount devices using the tried-and- tested RAM® mount system or can be mounted in a wall. The service lid on the back allows the exchange of the battery for the real-time clock as well as access to the USB 2.0 service interface. • The powerful electronics The integrated 32-bit controller and the operating system Embedded Linux are the basis for the visualisa- tion of the high-resolution graphics, the processing of the application program and the unit functions. Due to its universal software structure Embedded Linux furthermore provides many possibilities as regards com- munication and networking with other systems and networks. • Programming to IEC 61131-3 The CoDeSys software enables a clear and easy crea- tion of the application software for the user. Function libraries are available for the special functions of the display. The graphic elements are created and animated via the integrated visualisation. • The communication interfaces The PDM360 NG is equipped with up to four CAN interfaces to ISO 11898. These interfaces are for example used to exchange data with the connected controller, the de-centralised input/output modules or the engine controller. For this purpose the interfaces support the CANopen and the J1939 protocol among others. The integrated USB 2.0 interfaces provide easy data exchange with modern storage media. The Ethernet interface cannot only be used for pro- gramming but also for communication with other net- work participants. Applications: • Complex construction machines • Agricultural machines • Municipal vehicles Current consumption [mA] ≤ 300 Temperature range operation [°C] storage [°C] -30...65 -30...80 Display 7" TFT LCD display 800 x 480 pixels 18-bit colour depth Indication RGB LED Processor MPC5121/ PPC, 400 MHz Data memory Flash / SRAM [MB] 128 / 128 Internal mass storage [GB] (only CR1080 / CR1081) 1 Operating elements pushbuttons CR1080 (backlit) encoder 9 1 Operating elements pushbuttons CR1081 (backlit) rocker switch 9 1 Inputs (digital / analogue) 1 Inputs with special functions: Internal temperature sensors Photoelectric sensor 1 1 Outputs (digital) 1 Interfaces CR1080, CR1081 4 x CAN 1 x Ethernet 100 Mbits 2 x USB 2.0 Interfaces CR1083 2 x CAN 1 x Ethernet 100 Mbits 2 x USB 2.0 2 x analogue camera Supports CAN protocols CANopen (DS 301 V4) SAE J 1939 Programming software CoDeSys V2.3 Standards and tests (extract) CE, e1 (RL 2009/19/EC), BN 411 002 Control systems for mobile vehicles Controlsystems Dialogue module PDM360 NG with 8 function keys CR1083 Operating elements pushbuttons CR1083 (backlit) 8 For further technical data please go to: www.ifm.com

×