More Related Content
Similar to 02 - CONCOURSE - AREA 05A - SANITARY & STORM PIPING PLAN
Similar to 02 - CONCOURSE - AREA 05A - SANITARY & STORM PIPING PLAN (20)
More from Joseph Mayo (11)
02 - CONCOURSE - AREA 05A - SANITARY & STORM PIPING PLAN
- 1. 6G
H
.I.
J 5.
5.
4.
4.
L M N
11
1010
G.1
4.9
4.9
1' - 5 1/2"
9' - 8"
3 1/2"
1' - 2 1/4"
1' - 9 3/4"
3 3/8"
1'-77/8"
2'-101/2"
3'-17/8"
1' - 9 5/8"
2'-4"
5'-5"
8'-6"
10'-97/8"
11'-105/8"
71/2"
2'-21/4"
4'-91/4"
7'-41/4"
9'-113/8"
11'-73/4"
4"
CO
1'-67/8"
2'-73/8"
5'-8"
8'-93/8"
10'-97/8"
11'-97/8"
41/8"
5'-71/2"
8'-85/8"
12'-31/8"
13'-113/4"
3 3/8"
4' - 5 5/8"
3' - 1 1/4"
4' - 6 3/8"
1' - 1 1/8"
4 5/8"
3 7/8"
1 1/8"
4' - 3 1/2"
1' - 0"
5'-21/2"
8'-111/2"
3'-01/2"
2'-111/4"
6'-11/4"
9'-23/4"
10'-91/4"
13/4"
3'-15/8"
13' - 3 1/8"
1'-57/8"
1' - 5 5/8"
1 1/2"
1' - 3"
2' - 8 5/8"
8' - 3 1/8"
10'-91/4"
4" SAN
2" VENT
3" SAN
3" SAN
BP2205A.1BP2205A
1
BP2205A.1BP2205A
3
BP2205A.1BP2205A
4
BP2205A.1BP2205A
5
BP2205A.1BP2205A
6
2" VENT
6" SAN
2" VENT
2" VENT
2" VENT
4" SAN
2" VENT
4" SAN
2" VENT
4" SAN 2" VENT
2" VENT
3" VENT
4" VENT
4" VENT
4" VENT
2" VENT
2" VENT
2" VENT
6" SD
4" VENT
4" VENT
2" VENT
2" VENT
4" VENT
2" VENT
3" SAN
2" VENT
2" VENT
2" VENT
2" VENT
2" VENT
6" SD
EL: 4 1/8"
EL: 5"
EL: 6"
EL: 10' - 7"
EL: 11' - 4 7/8"
EL: 1 1/2"
EL: 11' - 6 3/8"
EL: 11' - 5 7/8"
EL: 11' - 5 5/8"
EL: 11' - 5 1/4"
EL: 11' - 5 5/8"
EL: 11' - 5 5/8"
EL: 12' - 10 1/8"
EL: 11' - 5 3/8"
EL: 11' - 5 7/8"
EL: 11' - 4 3/8"
EL: 4' - 7 1/8"
EL: 11' - 5 5/8"
EL: 5' - 2 1/4"
EL: 5' - 1 3/4"
EL: 5' - 1 1/4"
EL: 5' - 0 7/8"
EL: 12' - 7 1/2"
EL: 11' - 5 1/8"
EL: 2 7/8"
EL: 4' - 11 3/4"
EL: 5' - 11 5/8"
EL: 3"
EL: 5' - 3 1/8"
EL: 6' - 0 3/8"
EL: 3"
EL: 11' - 5 3/4"
EL: 11' - 5 1/2"
EL: 11' - 4"
EL: 11' - 6 3/8"
4" DN
6" DN
2" DN
2" DN
2" DN
6" UP
2" DN
2" DN
2" DN
4" DN
4" DN
2" DN
2" VENT
EL: 11' - 6 5/8"
2" DN
4: DN
2" DN
P-2
P-2
P-2
P-2
P-2A
P-2
P-1a P-1a
P-1
P-1
P-1
P-1
P-1
P-1
P-1
P-1
P-1
P-1
P-1
P-1
P-3a
P-3a
P-3a
P-3a
P-3a
P-3a
P-3a
P-3a
P-3a
WH-07
P-1a
P-6
FDR-1
3'-31/2"
12' - 1 5/8"
FDR-1
4'-117/8"
10' - 11 1/8"
FDR-1
FDR-1
4'-31/8"
11' - 3 1/2"
13'-113/4"
5' - 4"
P-4
P-13
(UNDER COUNTER)
P-13
(UNDER COUNTER)
1' - 0"
3'-5"
T U V
20.
21.
X
Z.10 W.
1111
1010
BP2205A.1BP2205A
2
10' - 7 7/8"
1' - 0 1/8"
3' - 10"
6' - 5 5/8"
9' - 0 3/4"
11' - 7 1/2"
12' - 8 5/8"
4' - 0 5/8"
5' - 11 1/8"
9' - 8 3/8"
2' - 4"
5' - 7"
1' - 8 1/8"
2' - 0 3/8" 1' - 2"
8'-01/4"
4'-55/8"
5'-35/8"
7'-07/8"
9'-03/8"
13'-107/8"
14'-43/8"
6'-05/8"
6'-111/4"
7'-25/8"
5'-13/4"
8'-85/8"
11'-101/2"
18'-11"
6'-111/4"
6" SD
12"-6"
NH SHORT RCR
12"-8"
NH SHORT RCR
12"-12"-12"
WYE
2" VENT
2" VENT
2" VENT
2" SAN 4" SAN
4"
CO
3" SAN
3" SAN
2" SAN
2" VENT
2" VENT 3" VENT
3" VENT
4" SAN
4"
CO
4" SAN
4" SAN
2" VENT
2" VENT
4" SAN
2" VENT
2" VENT
3" VENT
4" VENT
3" VENT
EL: 12' - 4 5/8"
EL: 4"
EL: 3' - 11 5/8"
EL: 12' - 1 1/8"
EL: 12' - 11 1/8"
EL: 14' - 3 1/8"
EL: 12' - 8 1/2"
EL: 12' - 2"
EL: 14' - 3 1/8"
EL: 12' - 3"
EL: 3' - 8 1/2"
EL: 12' - 4"
EL: 12' - 3 5/8"
EL: 12' - 3 3/4"
EL: 12' - 2 5/8"
EL: 4' - 0"EL: 4' - 0"
EL: 3 5/8"
EL: 3 3/4"
EL: 4' - 7 7/8"
EL: 5 3/4"
EL: 4' - 9 1/4"
EL: 6 7/8"
EL: 11' - 2 1/2"
10" UP
3" DN
4"
UP
2" DN
2" DN
3" UP
2" UP
4" DN
2"
DN
2" DN 2" DN
3" DN
2" DN
2" DN
2" DN
3" UP 3" DN
2" DN
4" DN
2" DN
9' - 7 1/8"
10' - 11 3/8"
FDR-1
P-13
(UNDER COUNTER)
2'-31/8"
5'-13/4"
5' - 6 3/4"
FDR-1
P-1a
P-1
P-3a
P-3
P-3
P-3a
P-1
P-1aP-3a
P-2 P-2 P-2P-2P-2a
12' - 1 1/4"
13'-31/8"
DATE :
BELL CORP.
1340 LEXINGTON,AVE.
ROCHESTER,N.Y 14606
PHONE:(585)-277-1000
FAX:(585)-277-1092
DRAWN BY
CHECKED BY
PROJECT NO.
FILENAME:PLOTBY:PLOTDATE:
RECORD OF TRADE COORDINATION
TRADE COMPANY DATE AUTHORIZED SIGNATURE
MECH
PLUMBER
SHT MTL
SPRINKLER
ELCTN
GC
BELL
BELL
PURPOSE
REF. DRAWING
NO DESCRIPTION DATE
REVISIONS
SPOOL LIST
1. ELEVATIONS SHOWN ARE TO FINISH FL:
PLAN NOTES:
2. ELEVATIONS ARE TO BOTTOM OF PIPE OR DUCT
BELL
FOR
CONSTRUCTION
C:UsersjmayoDocumentsCHS_PLMB_CENTRAL_jmayo.rvt11/12/20141:36:44PM
5500InternationalBlvd.#101,Charleston,SC29418-6911
TERMINALREDEVELOPMENTAND
IMPROVEMENTPROJECT(TRIP)
BP2205A
C93230
DLB
SANITARY AND STORM PIPING
PLAN - LEVEL 02 - AREA 05A -
MAGNIFIED
WCS
WCS
P4002
02 - CONCOURSE - 39'-6"
07/09/14
SCALE: 3/8" = 1'-0"
02 - CONCOURSE - AREA 05A - SANITARY & STORM PIPING PLAN
SCALE: 3/8" = 1'-0"
02 - CONCOURSE - AREA 05B - SANITARY & STORM PIPING PLAN
1 FOR CONSTRUCTION 9/24/14
2 ANNOTATION 11/11/14