SlideShare a Scribd company logo
1 of 26
Download to read offline
СВЯЗЬПРИБОР 
ЛИС 
ЛИС-М 
ЛИС-М+ 
Искатель скрытых коммуникаций 
РУКОВОДСТВО 
ПО ЭКСПЛУАТАЦИИ 
v 1.0
2
ОГЛАВЛЕНИЕ 
1 ____________________________________________4 НАЗНАЧЕНИЕ 
2 _______________________________________________5 ВВЕДЕНИЕ 
3 __________________________________________5 БЕЗОПАСНОСТЬ 
4 ____________________________________________7 СЕРТИФИКАТ 
5 ______________________________7 УСЛОВИЯ ЭКСПЛУАТАЦИИ 
6 _______________________8 ТЕХНИЧЕСКИЕ ХАРАКТЕРИСТИКИ 
7 ______________8 СОСТАВ ИЗДЕЛИЯ И КОМПЛЕКТ ПОСТАВКИ 
8 _________________________________9 ОПИСАНИЕ КОМПЛЕКТА 
8.1 ___________________________________________9 Искатель 
8.2 _________________________________________10 Генератор 
8.3 ____________________________10 Соединительные провода 
9 _________________________11 ПРИНЦИП РАБОТЫ КОМПЛЕКТА 
10 ________________________________11 ПОДГОТОВКА К РАБОТЕ 
10.1 __________________________12 Замена элементов питания 
11 _________________________13 ПОДКЛЮЧЕНИЕ И УПРАВЛЕНИЕ 
11.1 ____________________________13 Подключение генератора 
11.2 ________________________________15 Работа с искателем 
12 ____________________________________________17 ИЗМЕРЕНИЯ 
12.1 ____________17 Поиск проводов в потолках, стенах и полах 
12.2 __________________________________________________18 Идентификация предохранителей в распределительном щите 
12.3 _________________________________________________19 Обнаружение нелегальных обводов счетчиков электроэнергии 
12.4 __________________________19 Отбор проводника из пучка 
12.5 _______________________20 Локализация подземного кабеля 
12.6 _____________________________________________21 Локализация подземного кабеля с применением внешней антенны (ЛИС-М+) 
12.7 _________________22 Определение глубины залегания кабеля 
12.8 _____________________________________23 Определение глубины залегания кабеля с применением внешней антенны (ЛИС-М+) 
12.9 _____________________23 Поиск замыканий между жилами 
12.10 _____________________24 Поиск места обрыва проводов 
12.11 _25 Поиск скрытой проводки без применения генератора 
13 _______________________________25 ЧИСТКА И КОНСЕРВАЦИЯ 
14 _______________________25 ТРАНСПОРТИРОВКА И ХРАНЕНИЕ 
15 _26 СВЕДЕНИЯ О СОДЕРЖАНИИ ДРАГОЦЕННЫХ МЕТАЛЛОВ 
16 ________________________26 ГАРАНТИЙНЫЕ ОБЯЗАТЕЛЬСТВА 
17 ___________________________26 СВИДЕТЕЛЬСТВО О ПРИЕМКЕ 
3
1 
НАЗНАЧЕНИЕ 
искатель скрытых коммуникаций ЛИС-М (+) предназначен для: 
1) 
Поиск трассы проводов в потолках, стенах и полах; 
2) 
Обнаружение нелегальных обводов счетчиков электроэнергии; 
3) 
Идентификация выключателей и предохранителей; 
4) 
Поиск трасс замкнутых и оборванных цепей; 
5) 
Поиск трассы водопроводных труб и труб теплоснабжения; 
6) 
Поиск отдельных жил в системе проводов и кабелей; 
7) 
Поиск трассы кабеля, а также водопроводных труб и труб теплоснабжения в полевых условиях – для ЛИС-М+ 
и на глубине до 2 метров – для ЛИС-М; 
8) 
Отбор пар в многопарном кабеле; 
9) 
Определение глубины залегания провода. 
Искатель ЛИС позволяет фиксировать сигнал с частотой 26 250 ± 3 Гц и работает в комплекте с генератором ЛИС. Искатель ЛИС имеет встроенную антенну, а также может работать с внешней антенной (комплект ЛИС-М+). Применение внешней антенны значительно увеличивает чувствительность искателя и позволяет с большим удобством работать с подземными коммуникациями. Генератор ЛИС позволяет проводить измерения на кабелях без отключения электропитания до ~220 В. 
Электропитание искателя осуществляется от 2-х алколайновых батарей или Ni-Mh аккумуляторов типоразмера «АА». 
Электропитание генератора осуществляется от 4-х алколайновых батарей или Ni-Mh аккумуляторов типоразмера «АА». 
Индикация обнаружения трассы осуществляется визуально и звуковым способом через встроенный излучатель и внешние наушники. 
4
2 
ВВЕДЕНИЕ 
Благодарим Вас за покупку нашего комплекта для поиска скрытых коммуникаций ЛИС-М (+). 
Перед началом работы внимательно прочитайте Руководством по эксплуатации. Следуйте правилам безопасности и рекомендациями Производителя это позволит избежать ошибок при поиске коммуникаций и предотвратит возможные проблемы при использовании комплекта. 
В данном Руководстве текст в рамке со знаком , указывает на возможные опасности, как для пользователя, так и для комплекта. Текст, начинающийся со словом «ПРЕДУПРЕЖДЕНИЕ» указывает на ситуации, представляющие угрозу жизни или здоровью людей в случае невыполнения требований данного Руководства. Слово «ВНИМАНИЕ» указывает на ситуацию, в которой невыполнение данного Руководства грозит повреждением прибора. 
3 
БЕЗОПАСНОСТЬ 
ПРЕДУПРЕЖДЕНИЕ: 
 
КОМПЛЕКТ ЛИС МОЖЕТ ЭКСПЛУАТИРОВАТЬСЯ ТОЛЬКО КВАЛИФИЦИРОВАННЫМИ ЛИЦАМИ, ИМЕЮЩИМИ ТРЕБУЕМУЮ ГРУППУ ДОПУСКА ДЛЯ ИЗМЕРЕНИЙ В ЭЛЕКТРИЧЕСКИХ СЕТЯХ. РАБОТА ЛИЦ БЕЗ ДОПУСКА К РАБОТЕ С КОМПЛЕКТОМ МОЖЕТ ПРИВЕСТИ К ЕГО ПОВРЕЖДЕНИЮ И СТАТЬ ИСТОЧНИКОМ СЕРЬЕЗНОЙ ОПАСНОСТИ ДЛЯ ПОЛЬЗОВАТЕЛЯ 
 
НЕ РАЗБИРАЙТЕ ПРИБОР 
 
НЕ ДОПУСКАЕТСЯ ЭКСПЛУАТАЦИЯ ПРИБОРА С ПОВРЕЖДЕННЫМ КОРПУСОМ, НЕИСПРАВНОГО ПОЛНОСТЬЮ ИЛИ ЧАСТИЧНО, С ПОВРЕЖДЕННОЙ ИЗОЛЯЦИЕЙ ПРОВОДОВ, А ТАКЖЕ ХРАНИВШЕГОСЯ В АГРЕССИВНЫХ УСЛОВИЯХ 5
 
НЕ ДОПУСКАЕТСЯ ЭКСПЛУАТАЦИЯ ПРИБОРА В ВЗРЫВО-, ПОЖАРООПАСНЫХ ПОМЕЩЕНИЯХ 
 
ПЕРЕД ПОДКЛЮЧЕНИЕМ ГЕНЕРАТОРА К СЕТЕВЫМ КАБЕЛЯМ ИЛИ РОЗЕТКАМ ПРОВЕРЬТЕ НАЛИЧИЕ СЕТЕВОГО НАПРЯЖЕНИЯ И ПРИ ЕГО НАЛИЧИИ БУДЬТЕ ПРЕДЕЛЬНО ОСТОРОЖНЫ 
 
ПРИ ПОДКЛЮЧЕНИИ ГЕНЕРАТОРА К СЕТЕВОМУ КАБЕЛЮ БЕЗ ОТКЛЮЧЕНИЯ СЕТЕВОГО НАПРЯЖЕНИЯ СЛЕДУЕТ В ПЕРВУЮ ОЧЕРЕДЬ ПОДКЛЮЧИТЬ СОЕДИНИТЕЛЬНЫЕ ПРОВОДА К ГЕНЕРАТОРУ, ДАЛЕЕ 1-ЫЙ ПРОВОД ПОДКЛЮЧИТЬ К ЗАЗЕМЛЕНЮ, А УЖЕ ПОСЛЕ ЭТОГО 2-ОЙ ПРОВОД ПОДКЛЮЧИТЬ К ИСКОМОМУ КАБЕЛЮ 
 
НЕ ДОПУСКАЕТСЯ ОСТАВЛЯТЬ НЕ ПОДКЛЮЧЕННЫМ ОДИН ПРОВОД ГЕНЕРАТОРА ПРИ ПОДКЛЮЧЕНИИ ГЕНЕРАТОРА К СЕТЕВОМУ КАБЕЛЮ БЕЗ ОТКЛЮЧЕНИЯ СЕТЕВОГО НАПРЯЖЕНИЯ 
 
ПРИ ЗАМЕНЕ ЭЛЕМЕНТОВ ПИТАНИЯ, ОБЯЗАТЕЛЬНО ОТКЛЮЧИТЕ ГЕНЕРАТОР ОТ ВНЕШНИХ ЦЕПЕЙ 
 
ВЫКЛЮЧЕНИЕ ГЕНЕРАТОРА КНОПКОЙ НЕ ОТКЛЮЧАЕТ ВЫХОДНЫЕ КЛЕММЫ ОТ ВНУТРЕННИХ ЦЕПЕЙ 
Перед началом работы следует тщательно ознакомиться с настоящим Руководством; 
Прибор должен обслуживаться только лицами с соответствующей квалификацией; 
Ремонт может производиться только уполномоченными Сервисными центрами. 
6
4 
СЕРТИФИКАТ 
SVYAZPRIBOR Co Ltd 
170034 Russia, Tver, Koroleva str.9 
Directive RTTE 1999/5/WE on Radio Equipment and Telecommunication Terminal Equipment. 
Electromagnetic Compatibility EMC Directive 2004/108/WE 
Декларация о соответствии: РОСС RU.АЯ46.Д62614 
5 
УСЛОВИЯ ЭКСПЛУАТАЦИИ 
Комплект может эксплуатироваться: 
- на высоте до 2000 м над уровнем моря; 
- при температуре от +5 до +40 °С; 
- степень загрязнения воздуха – 2. 
ПРЕДУПРЕЖДЕНИЕ: 
НАРУШЕНИЕ УСЛОВИЙ ЭКСПЛУАТАЦИИ МОЖЕТ ВЫЗВАТЬ СНИЖЕНИЕ ХАРАКТЕРИСТИК ЭЛЕКТРОБЕЗОПАСНОСТИ ПРИБОРА 7
6 
ТЕХНИЧЕСКИЕ ХАРАКТЕРИСТИКИ 
Искатель 
Активная частота: 
26250 ± 3 Гц 
Полоса пропускания по уровню –3 дБ (не более) 
150 Гц 
Максимально определяемая глубина залегания трассы 
2 м 
Точность отыскания 
1 см 
Время непрерывной работы (не менее) 
20 ч 
Электропитание: алколайновые батареи или Ni- Mh, 2,3 А/ч аккумуляторы 
2 шт. АА 
Степень защиты корпуса 
IP42 
Габаритные размеры прибора 
135х70х24 мм 
Масса прибора (включая элементы питания) 
0,20 кг 
Габаритные размеры внешней антенны 
900х200х40 мм 
Генератор 
Выходной сигнал частота: 
26252 ± 1 Гц 
Выходная мощность 
1 вт 
Время непрерывной работы (не менее) 
20 ч 
Электропитание: алколайновые батареи или Ni-Mh, 2,1 А/ч аккумуляторы 
4 шт. АА 
Степень защиты корпуса 
IP42 
Габаритные размеры прибора (без сумки) 
180х65х27 
Масса прибора (без элементов питания) 
0,20 кг 
7 
СОСТАВ ИЗДЕЛИЯ И КОМПЛЕКТ ПОСТАВКИ 
№ 
Наименование 
Кол-во 
1. 
Искатель ЛИС 
1 
2. 
Генератор ЛИС 
1 
3. 
Комплект проводов универсальный для подключения генератора к нагрузке 
1 
4. 
Датчик 
1 
5. 
Руководство по эксплуатации 
1 
6. 
Сумка 
1 
7. 
Приемная антенна (комплектуется только ЛИС-М+) 
1 
8
8 О 
ПИСАНИЕ КОМПЛЕКТА 
8. 
1 Искатель 
На лицевой панели искателя расположены: 
1. 
Стрелка указывающая расположение датчика в корпусе прибора 
2. 
Разъем для подключения внешнего датчика или антенны 
3. 
индикатор уровня сигнала 
4. 
индикатор включения искателя 
 н 
е горит – выключено 
 
мигает – включено, элементы питания разряжены 
 го 
рит непрерывно - 
вк 
лючено 
5. - кнопка включения искателя 
6. 
индикатор включения фонового режима - кнопка включения фонового режима 
7. - кнопки изменения чувствительности искателя 
8 
. 
9 
. - кнопка включения встроенного фонарика 10. разъем дл 
9
8 
.2 Генератор 
На лицевой панели генератора расположены: 
1. 
выходные клеммы 
2. 
индикатор выходной мощности генератора 
 н 
е горит – минимальная мощность 
 м 
игает – средняя 
 г 
орит непрерывно – 
максимальная 
3. 
- кнопка регулировки мощности выходного сигнала 
4. 
индикатор включения питания 
 н 
е горит – выключено 
 м 
игает – включено, элементы питания разряжены 
 
горит непрерывно – включено 
5 
. - кнопка включения генератора 
8 
.3 Соединительные провода 
Комплект поставляется с универсальным набором соединительных проводов. На изолированные концы проводов могут надеваться как зажимы «Крокодил», так и зонды, поставляемые с проводами. 
10
9 П 
РИНЦИП РАБОТЫ КОМПЛЕКТА 
Генератор ЛИС является источником характерного сигнала, подключаемым к жиле искомого кабеля. Протекающий по кабелю переменный ток создает вокруг него магнитное поле, которое индуцирует сигнал в индуктивном датчике искателя. Принятый сигнал поступает в приемное устройство искателя, где осуществляется аналоговая и цифровая обработка. Полученные результаты выводятся на светодиодный индикатор и звуковой излучатель. 
10 
ПОДГОТОВКА К РАБОТЕ 
При получении комплекта искателя распакуйте его и внешним осмотром убедитесь в отсутствии механических повреждений корпусов и элементов, расположенных на лицевых панелях искателя и генератора. Если приборы хранились при повышенной влажности или в условиях низких температур, просушите его в течение 24 ч в нормальных условиях. 
ВНИМАНИЕ 
 
ВО ИЗБЕЖАНИЕ ПОВРЕЖДЕНИЯ НЕ ДОПУСКАЕТСЯ ДЛИТЕЛЬНОЕ ХРАНЕНИЕ ИСКАТЕЛЯ С УСТАНОВЛЕННЫМИ ЭЛЕМЕНТАМИ ПИТАНИЯ 
 
НЕ ДОПУСКАЙТЕ ПОПАДАНИЯ ВОДЫ И ДРУГИХ ЖИДКОСТЕЙ ВО ВНУТРЬ КОРПУСА ПРИБОРА 
Установите элементы питания в соответствии с пунктом «Замена элементов питания» 
11
1 
0.1 Замена элементов питания 
ПРЕДУПРЕЖДЕНИЕ: 
ПРИ ЗАМЕНЕ ЭЛЕМЕНТОВ ПИТАНИЯ, ОБЯЗАТЕЛЬНО ОТКЛЮЧИТЕ ГЕНЕРАТОР ОТ ВНЕШНИХ ЦЕПЕЙ 
Электропитание искателя осуществляется от 2-х Ni-Mh аккумуляторов с напряжением 1,2 В и емкостью 2,3 А/ч или алкалайновых батарей типоразмера «АА». 
Откройте батарейный отсек на нижней стороне искателя и замените элементы питания, соблюдая полярность. 
Электропитание генератора осуществляется от 4-х Ni-Mh аккумуляторов с напряжением 1,2 В и емкостью 2,3 А/ч или алкалайновых батарей типоразмера «АА» 
Откройте батарейный отсек на нижней стороне генератора, открутив 1 винт, и замените элементы питания, соблюдая полярность. 
Включите прибор, нажав кнопку . При правильной установке элементов питания и их достаточной степени заряда свидетельствует зажигание индикатора питания. При разряде элементов питания индикатор начнет пульсировать, а при полном разряде искатель отключается. 
Включение и индикация разряда в генераторе и искателе организованы аналогично. 
12
11 
ПОДКЛЮЧЕНИЕ И УПРАВЛЕНИЕ 
11. 
1 Подключение генератора 
На работающем сетевом кабеле генератор испытательных сигналов может быть подключен непосредственно к жиле без отключения напряжения. 
ВНИМАНИЕ 
НЕДОПУСКАЕТСЯ ПОДКЛЮЧЕНИЕ ГЕНЕРАТОРА К КАБЕЛЮ С НАПРЯЖЕНИЕМ ВЫШЕ ~220 В 
ПРЕДУПРЕЖДЕНИЕ: 
ПРИ ПОДКЛЮЧЕНИИ ГЕНЕРАТОРА К СЕТЕВОМУ КАБЕЛЮ БЕЗ ОТКЛЮЧЕНИЯ СЕТЕВОГО НАПРЯЖЕНИЯ СЛЕДУЕТ В ПЕРВУЮ ОЧЕРЕДЬ ПОДКЛЮЧИТЬ СОЕДИНИТЕЛЬНЫЕ ПРОВОДА К ГЕНЕРАТОРУ, ДАЛЕЕ 1 ПРОВОД ПОДКЛЮЧИТЬ К ЗАЗЕМЛЕНЮ, А УЖЕ ПОСЛЕ ЭТОГО ПОДКЛЮЧИТЬ К ИСКОМОМУ КАБЕЛЮ 
13
Выходные клеммы генератора равнозначны, и при подключении можно выбирать любую клемму. 
Подключение генератора к кабелю: 
способ 1: любой вывод генератора подключить к жиле скрытой проводки, второй вывод ко второй жиле этой же скрытой проводки (например к розетке). 
При подключении таким способом следует учитывать что подключение к двум жилам одного провода вызывает эффект компенсации, что приводит к значительному уменьшению уровня сигнала. По этому предпочтительнее использовать способ 2 или 3. 
способ 2: вывод генератора подключить к жиле скрытой проводки, второй вывод к этой же жиле на дальнем конце проводки (например провод теплых полов) 
способ 3: вывод генератора подключить к жиле скрытой проводки, второй вывод к шине заземления (заземление в другой розетке, батарея центрального отопления, водопроводная труба). 
При включении генератора автоматически включается режим минимальной выходной мощности, индикатор выходной мощности не светится. В некоторых случаях описанных ниже требуется изменить выходную мощность генератора. Для увеличения нажмите один раз 14
кнопку , индикатор начнет мигать, что соответствует средней выходной мощности. Для включения максимальной выходной мощности нажмите еще один раз кнопку, индикатор начнет светиться непрерывно – максимальная выходная мощность. При нажатии на кнопку генератор вернется в режим минимальной выходной мощности 
1 
1.2Работа с искателем 
Регулировка усиления (меньше) ил При поиске трассы установите кнопкам (больше) показания индикатора в пределах шкал 
В момент нажатия кнопки или на индикаторе уровня сигнала кратковременно отображается положение регулятора усиления. 
Размещение антенны в корпусе искателя 
Для точного определения трассы следует учитывать расположение датчика в корпусе прибора. Расположение показано на передней панели приемника стрелкой. 
Режимы поиска и определения направления 
При поиске скрытого кабеля в зависимости от ориентации искателя существует два метода поиска «по максимуму» и «по минимуму». 
15
Поиск по максимуму: при данном расположении датчика над центром кабеля, уровень сигнала максимален. Этот способ используется для примерного определения расположения кабеля. 
Поиск по минимуму: при данном расположении датчика над центром кабеля, уровень сигнала минимален. При таком способе поиска достигается наибольшая точность отыскания. 
Определение направления прокладки кабеля: при вращении искателя вокруг своей оси над кабелем, положение с минимальным уровнем сигнала покажет направление прокладки кабеля. 16
12 
ИЗМЕРЕНИЯ 
1 
2.1 Поиск проводов в потолках, стенах и полах 
Подключите генератор как описано в пункте «Подключение генератора» способ 2: первый вывод к жиле скрытой проводки, второй вывод к этой же жиле на дальнем конце проводки (например к выводам провода теплого пола). Проводите поиск скрытой проводки ориентируясь по максимальному уровню сигнала. Для более точного определения местоположения трассы следует проводить поиск по минимуму. Теперь ориентируясь по минимальному уровню сигнала, определите точное расположение трассы. 
При невозможности подключить генератор как описано в пункте «Подключение генератора» способ. 2, можно провести поиск подключив генератор одним выводом к жиле обследуемого кабеля, вторым к заземлению, (пункт «Подключение генератора» способ 3.). Проведите поиск скрытой проводки, ориентируясь по максимальному уровню сигнала. 
17
1 
2.2 Идентификация предохранителей в распределительном щите 
Определите прохождение скрытой проводки до распределительного щита (пункт «Поиск проводов в потолках, стенах и полах»). 
Подключите генератор как описано в пункте «Подключение генератора» способ 1 первый вывод к жиле искомого кабеля, второй ко второй жиле того же кабеля. Включите генератор на минимальной мощности (при большом удалении от места подключения мощность генератора следует увеличить кнопкой ). Поднося приемник к предохранителям или выключателям определите искомый выключатель, ориентируясь по максимуму уровня сигнала. 
Поскольку современные предохранители, в частности выключатели дифференцированного тока, имеют внутри один или более витков провода, может оказаться, что понадобится различная ориентация приемника и повторение попыток локализации. 18
12.3 
Обнаружение нелегальных обводов счетчиков электроэнергии 
Подключите генератор одним вывод к жиле обследуемого кабеля, вторым к заземлению, (пункт «Подключение генератора» способ 3.) Продвигаясь по трассе скрытой проводки, располагайте приемник как показано на рисунке. Резкое повышение уровня сигнала свидетельствует о наличии отвода. 
12 
.4 Отбор проводника из пучка 
Подключите генератор одним вывод к жиле искомого проводника, вторым к заземлению, («Подключение генератора» способ 3.). Неиспользуемые проводники следует также заземлить. Включите генератор на максимальной мощности. 
Подключите к искателю внешний датчик. Поочередно касаясь приемником всех проводников, определите «свой» проводник по максимальному уровню сигнала. 
19
12.5 
Локализация подземного кабеля 
Для поиска трассы выход генератора подключают одним проводом к жиле кабеля, другим - к штырю заземления. Штырь заземления относится на 10 - 20 м в сторону от трассы. Жилу кабеля на дальнем конце, если возможно, следует заземлить. 
Включите генератор. Установите максимальную мощность выходного сигнала. 
Включите приемник. Расположите приемник над трассой как показано на рисунке. Ориентируясь по максимальному сигналу, продвигайтесь вдоль трассы. Для более точного определения местоположения трассы следует проводить поиск по минимуму (пункт «Подключение генератора»). Теперь ориентируясь по минимальному уровню сигнала, определите точное расположение трассы. 
20
12.6 
Локализация подземного кабеля с применением внешней антенны (ЛИС-М+) 
Подключение генератора осуществляется, так же как и без применения внешней антенны. Описание дано в предыдущем пункте. 
Подключите к разъему искателя внешнюю антенну. Для удобства работы датчик расположен под углом 45°. Расположение кабеля определяется по максимуму показаний индикатора при расположении антенны как показано на рисунке (а). 
Уточнение расположения кабеля производится по минимуму сигнала при расположении антенны как показано на рисунке (б). 
Для этого необходимо расположить датчик вертикально и добиться минимальных показаний индикатора. Зависимость уровня 21
сигнала от положения антенны над трассой и режима поиска показано на рисунке. 
12 
.7 Определение глубины залегания кабеля 
Подключите генератор: 
первый вывод к жиле скрытой проводки, второй вывод к этой же жиле на дальнем конце проводки (пункт «Подключение генератора» способ 2) или первый вывод к жиле искомого кабеля, второй 
емлению (пункт «Подключение генератора» способ 3) Определите точное расположение искомого провода (кабеля). Для определения глубины залегания, расположите прибор на поверхности стены или земли в максимуме сигнала. Установите усиление так, чтобы показания были в пределах шкалы светодиодного индикатора. Отводя прибор от стены (земли), добейтесь вдвое меньших показаний. Расстояние от прибора до 
22
12.8 
Определение глубины залегания кабеля с применением внешней антенны (ЛИС-М+) 
Подключите генератор как сказано в предыдущем пункте. Подключите к разъему искателя внешнюю антенну. Наилучшие результаты достигаются при работе по «минимуму» сигнала. Определите точное расположение искомого провода (кабеля). 
Расположите антенну вертикально над точкой прохождения трассы как показано на рисунке, вид а). Отводите антенну в сторону перпендикулярно трассе до точки, где уровень сигнала будет минимален, вид б). Расстояние между точками – hизм будет равно глубине залегания трассы - h. 
12.9 
Поиск замыканий между жилами 
Подключите генератор к любой жиле кабеля, пункт «Подключение генератора» способ 3. Включите генератор на минимальную мощность. Определите трассу проводки. Только после разметки трассы начинайте поиск КЗ. 23
Подключите генератор между замкнутыми жилами кабеля, пункт «Подключение генератора» способ 1. Включите генератор на максимальную мощность. Продвигайтесь по размеченной трассе и наблюдайте за уровнем сигнала. В месте короткого замыкания наблюдается понижение уровня сигнала. Причем после места КЗ сигнал будет прослушиваться, но с меньшим уровнем. Для уточнения места КЗ следует подключить генератор на дальнем конце и повторить поиск. Результат должен повторится! 
12.1 
0 Поиск места обрыва проводов 
Подключите генератор как описано в пункте «Подключение генератора» способ 3 первый вывод к жиле искомого кабеля, второй к заземлению. Включите генератор на минимальной мощности (при большом удалении от места подключения мощность генератора следует увеличить кнопкой ). Для обнаружения обрыва жил кабеля необходимо заземлить все жилы кроме подключенной к генератору, а также все жилы на дальнем конце кабеля. 
К искателю подключите внешний датчик. Продвигайтесь по трассе по максимуму сигнала, в месте обрыва сигнал уменьшается. 
24
12.1 
1 Поиск скрытой проводки без применения генератора 
Включите на искателе широкополосный режим, нажав кнопку . Проводите поиск скрытой проводки находящейся под напряжением ориентируясь по максимальному уровню сигнала. Наилучшие результаты достигаются при подключении нагрузки к искомой проводке. 
Также можно отыскать любые шумящие трассы. 
При данном способе поиска уровень сигнала зависит от ориентации датчика относительно искомого кабеля. 
13 ЧИ 
СТКА И КОНСЕРВАЦИЯ 
Корпуса передатчика и приемника можно протирать мягкой влажной фланелью с использованием общедоступных моющих средств. Нельзя пользоваться растворителями и чистящими средствами, которые могут поцарапать корпус (порошки, пасты и так далее). 
Электронная схема прибора не требует консервации. 
14 ТР 
АНСПОРТИРОВКА И ХРАНЕНИЕ 
Транспортирование комплектов искателя скрытых коммуникаций производится в упакованном виде железнодорожным или автомобильным транспортом в крытых вагонах или закрытых автомашинах в соответствии с правилами перевозки грузов, действующих на данном виде транспорта. 
В помещениях для хранения не должно быть паров кислот и щелочей, агрессивных газов и других вредных примесей, вызывающих коррозию. 
ПЕРЕД ДЛИТЕЛЬНЫМ ХРАНЕНИЕМ, ВО ИЗБЕЖАНИЕ ПОВРЕЖДЕНИЯ БАТАРЕИ, ИХ СЛЕДУЕТ ВЫНУТЬ ИЗ ПРИБОРОВ. 
25
26 
15 СВ 
ЕДЕНИЯ О СОДЕРЖАНИИ ДРАГОЦЕННЫХ МЕТАЛЛОВ 
Драгоценных металлов прибор не содержит. 
16 ГА 
РАНТИЙНЫЕ ОБЯЗАТЕЛЬСТВА 
Завод-изготовитель гарантирует работоспособность искателя скрытых коммуникаций при соблюдении условии эксплуатации, хранения, транспортирования, указанных в настоящем техническом описании. 
Гарантийный срок эксплуатации - 12 месяцев с момента продажи прибора. 
Гарантийные обязательства не распространяются на батареи. 
В случае выхода из строя прибора потребителем должно быть составлено сопроводительное письмо с указанием неисправности и подробным обратным адресом с указанием контактных телефонов. 
Письмо вместе с комплектом высылается предприятию- изготовителю по адресу: 
170030, г. Тверь, ул. Королева, д. 9, ООО «СВЯЗЬПРИБОР» 
тел.: (4822) 42-54-91, 72-52-76, 51-50-72 факс: (4822) 42-54-91 
E-mail: support@svpribor.ru http://www.svpribor.ru 
17 СВ 
ИДЕТЕЛЬСТВО О ПРИЕМКЕ 
Искатель скрытых коммуникаций ЛИС, заводской № ______________ соответствует ТУ 4221-021-40720371-12 и признан годным к эксплуатации. 
Представитель завода __________________

More Related Content

What's hot

7.2 Каталог Easy 9 Schneider Electric
7.2 Каталог Easy 9 Schneider Electric7.2 Каталог Easy 9 Schneider Electric
7.2 Каталог Easy 9 Schneider ElectricIgor Golovin
 
астра, теко
астра, текоастра, теко
астра, текоjournalrubezh
 
1.2.9 Промышленные разъемы
1.2.9 Промышленные разъемы1.2.9 Промышленные разъемы
1.2.9 Промышленные разъемыIgor Golovin
 
Решение для оптимищзации и контроля напряжения
Решение для оптимищзации и контроля напряженияРешение для оптимищзации и контроля напряжения
Решение для оптимищзации и контроля напряженияMAYKOR
 
радиозонд малогабаритный и 2012
радиозонд малогабаритный и 2012радиозонд малогабаритный и 2012
радиозонд малогабаритный и 2012smoker403
 
Грибков М.А. - ПАО "МОЭСК"
Грибков М.А. - ПАО "МОЭСК"Грибков М.А. - ПАО "МОЭСК"
Грибков М.А. - ПАО "МОЭСК"DigitalSubstation
 
ссво от 06.11.2015
ссво от 06.11.2015 ссво от 06.11.2015
ссво от 06.11.2015 smoker403
 
система связи и_телемеханики_сстм
система связи и_телемеханики_сстмсистема связи и_телемеханики_сстм
система связи и_телемеханики_сстмsmoker403
 
ПС 110 кВ "Приречная"
ПС 110 кВ "Приречная"ПС 110 кВ "Приречная"
ПС 110 кВ "Приречная"DigitalSubstation
 
Защита информации от ВЧ навязывания и ВЧ облучения
Защита информации от ВЧ навязывания и ВЧ облученияЗащита информации от ВЧ навязывания и ВЧ облучения
Защита информации от ВЧ навязывания и ВЧ облученияkzissu
 
Контакторы малогабаритные серии КМИ
Контакторы малогабаритные серии КМИКонтакторы малогабаритные серии КМИ
Контакторы малогабаритные серии КМИalukianov
 
НАУЧНЫЕ РАЗРАБОТКИ 2011
НАУЧНЫЕ РАЗРАБОТКИ 2011 НАУЧНЫЕ РАЗРАБОТКИ 2011
НАУЧНЫЕ РАЗРАБОТКИ 2011 is1003
 
Реализация цифровых комплексов РЗА в ПАО «РусГидро». Итоги предварительных на...
Реализация цифровых комплексов РЗА в ПАО «РусГидро». Итоги предварительных на...Реализация цифровых комплексов РЗА в ПАО «РусГидро». Итоги предварительных на...
Реализация цифровых комплексов РЗА в ПАО «РусГидро». Итоги предварительных на...DigitalSubstation
 
Ограничители импульсных перенапряжений ОПС1
Ограничители импульсных перенапряжений ОПС1Ограничители импульсных перенапряжений ОПС1
Ограничители импульсных перенапряжений ОПС1alukianov
 
Сакмарская СЭС и новые разработки Прософт-Системы
Сакмарская СЭС и новые разработки Прософт-СистемыСакмарская СЭС и новые разработки Прософт-Системы
Сакмарская СЭС и новые разработки Прософт-СистемыDigitalSubstation
 

What's hot (20)

7.2 Каталог Easy 9 Schneider Electric
7.2 Каталог Easy 9 Schneider Electric7.2 Каталог Easy 9 Schneider Electric
7.2 Каталог Easy 9 Schneider Electric
 
астра, теко
астра, текоастра, теко
астра, теко
 
1.2.9 Промышленные разъемы
1.2.9 Промышленные разъемы1.2.9 Промышленные разъемы
1.2.9 Промышленные разъемы
 
Решение для оптимищзации и контроля напряжения
Решение для оптимищзации и контроля напряженияРешение для оптимищзации и контроля напряжения
Решение для оптимищзации и контроля напряжения
 
Oritemp2000
Oritemp2000Oritemp2000
Oritemp2000
 
радиозонд малогабаритный и 2012
радиозонд малогабаритный и 2012радиозонд малогабаритный и 2012
радиозонд малогабаритный и 2012
 
Грибков М.А. - ПАО "МОЭСК"
Грибков М.А. - ПАО "МОЭСК"Грибков М.А. - ПАО "МОЭСК"
Грибков М.А. - ПАО "МОЭСК"
 
ссво от 06.11.2015
ссво от 06.11.2015 ссво от 06.11.2015
ссво от 06.11.2015
 
презентация линтех
презентация линтехпрезентация линтех
презентация линтех
 
система связи и_телемеханики_сстм
система связи и_телемеханики_сстмсистема связи и_телемеханики_сстм
система связи и_телемеханики_сстм
 
ПС 110 кВ "Приречная"
ПС 110 кВ "Приречная"ПС 110 кВ "Приречная"
ПС 110 кВ "Приречная"
 
Scb
ScbScb
Scb
 
Автомат контроля изоляции АКИ-2М
Автомат контроля изоляции АКИ-2МАвтомат контроля изоляции АКИ-2М
Автомат контроля изоляции АКИ-2М
 
Защита информации от ВЧ навязывания и ВЧ облучения
Защита информации от ВЧ навязывания и ВЧ облученияЗащита информации от ВЧ навязывания и ВЧ облучения
Защита информации от ВЧ навязывания и ВЧ облучения
 
Контакторы малогабаритные серии КМИ
Контакторы малогабаритные серии КМИКонтакторы малогабаритные серии КМИ
Контакторы малогабаритные серии КМИ
 
НАУЧНЫЕ РАЗРАБОТКИ 2011
НАУЧНЫЕ РАЗРАБОТКИ 2011 НАУЧНЫЕ РАЗРАБОТКИ 2011
НАУЧНЫЕ РАЗРАБОТКИ 2011
 
Реализация цифровых комплексов РЗА в ПАО «РусГидро». Итоги предварительных на...
Реализация цифровых комплексов РЗА в ПАО «РусГидро». Итоги предварительных на...Реализация цифровых комплексов РЗА в ПАО «РусГидро». Итоги предварительных на...
Реализация цифровых комплексов РЗА в ПАО «РусГидро». Итоги предварительных на...
 
Пуляев В.И.
Пуляев В.И.Пуляев В.И.
Пуляев В.И.
 
Ограничители импульсных перенапряжений ОПС1
Ограничители импульсных перенапряжений ОПС1Ограничители импульсных перенапряжений ОПС1
Ограничители импульсных перенапряжений ОПС1
 
Сакмарская СЭС и новые разработки Прософт-Системы
Сакмарская СЭС и новые разработки Прософт-СистемыСакмарская СЭС и новые разработки Прософт-Системы
Сакмарская СЭС и новые разработки Прософт-Системы
 

Viewers also liked

Reynolds joanne 4.4
Reynolds joanne 4.4Reynolds joanne 4.4
Reynolds joanne 4.4jorey1687
 
atheism-a-philosophical-justification
atheism-a-philosophical-justificationatheism-a-philosophical-justification
atheism-a-philosophical-justificationCobol Engineering
 
Kalam debunked from iron chariots wiki
Kalam debunked from iron chariots wikiKalam debunked from iron chariots wiki
Kalam debunked from iron chariots wikiCobol Engineering
 
the sk3ptic 3ncyclopedia of ps3udoscience
the sk3ptic 3ncyclopedia of ps3udosciencethe sk3ptic 3ncyclopedia of ps3udoscience
the sk3ptic 3ncyclopedia of ps3udoscienceCobol Engineering
 
Technology used in World War 2
Technology used in World War 2Technology used in World War 2
Technology used in World War 2karolinaoles
 
Health Sciences 3P37: Finding qualitative and quantitative studies
Health Sciences 3P37: Finding qualitative and quantitative studiesHealth Sciences 3P37: Finding qualitative and quantitative studies
Health Sciences 3P37: Finding qualitative and quantitative studiesLydia Thorne
 
Women during World War 1
Women during World War 1Women during World War 1
Women during World War 1karolinaoles
 
Open Access Week 2015
Open Access Week 2015Open Access Week 2015
Open Access Week 2015Lydia Thorne
 
Nursing 3P70: Information Sources for Nursing Research
Nursing 3P70: Information Sources for Nursing ResearchNursing 3P70: Information Sources for Nursing Research
Nursing 3P70: Information Sources for Nursing ResearchLydia Thorne
 

Viewers also liked (13)

Gustavorea
GustavoreaGustavorea
Gustavorea
 
Gustavorea
GustavoreaGustavorea
Gustavorea
 
Reynolds joanne 4.4
Reynolds joanne 4.4Reynolds joanne 4.4
Reynolds joanne 4.4
 
atheism-a-philosophical-justification
atheism-a-philosophical-justificationatheism-a-philosophical-justification
atheism-a-philosophical-justification
 
Deans Resume 2014
Deans Resume 2014Deans Resume 2014
Deans Resume 2014
 
Kalam debunked from iron chariots wiki
Kalam debunked from iron chariots wikiKalam debunked from iron chariots wiki
Kalam debunked from iron chariots wiki
 
the sk3ptic 3ncyclopedia of ps3udoscience
the sk3ptic 3ncyclopedia of ps3udosciencethe sk3ptic 3ncyclopedia of ps3udoscience
the sk3ptic 3ncyclopedia of ps3udoscience
 
Ece 214 week 5 dq 2
Ece 214 week 5 dq 2Ece 214 week 5 dq 2
Ece 214 week 5 dq 2
 
Technology used in World War 2
Technology used in World War 2Technology used in World War 2
Technology used in World War 2
 
Health Sciences 3P37: Finding qualitative and quantitative studies
Health Sciences 3P37: Finding qualitative and quantitative studiesHealth Sciences 3P37: Finding qualitative and quantitative studies
Health Sciences 3P37: Finding qualitative and quantitative studies
 
Women during World War 1
Women during World War 1Women during World War 1
Women during World War 1
 
Open Access Week 2015
Open Access Week 2015Open Access Week 2015
Open Access Week 2015
 
Nursing 3P70: Information Sources for Nursing Research
Nursing 3P70: Information Sources for Nursing ResearchNursing 3P70: Information Sources for Nursing Research
Nursing 3P70: Information Sources for Nursing Research
 

Similar to D7c6ae90

NP-06 TD ME.3F.TxPD-U
NP-06 TD ME.3F.TxPD-UNP-06 TD ME.3F.TxPD-U
NP-06 TD ME.3F.TxPD-Umetersite
 
Генераторы электромагнитного шума
Генераторы электромагнитного шумаГенераторы электромагнитного шума
Генераторы электромагнитного шумаkzissu
 
NP-06 TD ME.3FD.SMxPD-U
NP-06 TD ME.3FD.SMxPD-UNP-06 TD ME.3FD.SMxPD-U
NP-06 TD ME.3FD.SMxPD-Umetersite
 
INVT_КАТАЛОГ ИНВЕРТОРОВ ДЛЯ СОЛНЕЧНЫХ БАТАРЕЙ_2023.4.10.pdf
 INVT_КАТАЛОГ ИНВЕРТОРОВ ДЛЯ СОЛНЕЧНЫХ БАТАРЕЙ_2023.4.10.pdf INVT_КАТАЛОГ ИНВЕРТОРОВ ДЛЯ СОЛНЕЧНЫХ БАТАРЕЙ_2023.4.10.pdf
INVT_КАТАЛОГ ИНВЕРТОРОВ ДЛЯ СОЛНЕЧНЫХ БАТАРЕЙ_2023.4.10.pdfSamuel Ou
 
Новинки продукции 2012
Новинки продукции 2012Новинки продукции 2012
Новинки продукции 2012ekfenergy
 
Micro Scanner2 Getting Started Guide Rus
Micro Scanner2 Getting Started Guide RusMicro Scanner2 Getting Started Guide Rus
Micro Scanner2 Getting Started Guide Ruskvz
 
Техническое описание счетчиков однофазных типа Np 06
Техническое описание счетчиков однофазных типа Np 06Техническое описание счетчиков однофазных типа Np 06
Техническое описание счетчиков однофазных типа Np 06metersite
 
Hioki pw6001 rus
Hioki pw6001 rusHioki pw6001 rus
Hioki pw6001 rushiokirus
 
Hioki pw6001 rus
Hioki pw6001 rusHioki pw6001 rus
Hioki pw6001 rushiokirus
 
Сварог tig200,315 p-dsp_ac_dc
Сварог tig200,315 p-dsp_ac_dcСварог tig200,315 p-dsp_ac_dc
Сварог tig200,315 p-dsp_ac_dcABoytsov
 
Каталог продукции ООО Харьковэнергоприбор
Каталог продукции ООО ХарьковэнергоприборКаталог продукции ООО Харьковэнергоприбор
Каталог продукции ООО ХарьковэнергоприборKEP Power Testing Ltd.
 
Филин-А
Филин-АФилин-А
Филин-АNTCRTS
 
Vnx.su системы впрыска sandero
Vnx.su системы впрыска sanderoVnx.su системы впрыска sandero
Vnx.su системы впрыска sanderovnx21
 
Специализированная аппаратура ВЧ связи для РЗ и ПА. Отличительные особенности...
Специализированная аппаратура ВЧ связи для РЗ и ПА. Отличительные особенности...Специализированная аппаратура ВЧ связи для РЗ и ПА. Отличительные особенности...
Специализированная аппаратура ВЧ связи для РЗ и ПА. Отличительные особенности...ООО "Прософт-Системы"
 
http://vnx.su/ thalia-symbol-2-diagnostika
http://vnx.su/ thalia-symbol-2-diagnostikahttp://vnx.su/ thalia-symbol-2-diagnostika
http://vnx.su/ thalia-symbol-2-diagnostikareno-rez
 
NP-06 TD MME.1F.1SM-U
NP-06 TD MME.1F.1SM-UNP-06 TD MME.1F.1SM-U
NP-06 TD MME.1F.1SM-Umetersite
 
Hioki pw3198 rus
Hioki pw3198 rusHioki pw3198 rus
Hioki pw3198 rushiokirus
 
Hioki pw3198
Hioki pw3198Hioki pw3198
Hioki pw3198hiokirus
 

Similar to D7c6ae90 (20)

NP-06 TD ME.3F.TxPD-U
NP-06 TD ME.3F.TxPD-UNP-06 TD ME.3F.TxPD-U
NP-06 TD ME.3F.TxPD-U
 
Генераторы электромагнитного шума
Генераторы электромагнитного шумаГенераторы электромагнитного шума
Генераторы электромагнитного шума
 
NP-06 TD ME.3FD.SMxPD-U
NP-06 TD ME.3FD.SMxPD-UNP-06 TD ME.3FD.SMxPD-U
NP-06 TD ME.3FD.SMxPD-U
 
INVT_КАТАЛОГ ИНВЕРТОРОВ ДЛЯ СОЛНЕЧНЫХ БАТАРЕЙ_2023.4.10.pdf
 INVT_КАТАЛОГ ИНВЕРТОРОВ ДЛЯ СОЛНЕЧНЫХ БАТАРЕЙ_2023.4.10.pdf INVT_КАТАЛОГ ИНВЕРТОРОВ ДЛЯ СОЛНЕЧНЫХ БАТАРЕЙ_2023.4.10.pdf
INVT_КАТАЛОГ ИНВЕРТОРОВ ДЛЯ СОЛНЕЧНЫХ БАТАРЕЙ_2023.4.10.pdf
 
Новинки продукции 2012
Новинки продукции 2012Новинки продукции 2012
Новинки продукции 2012
 
Micro Scanner2 Getting Started Guide Rus
Micro Scanner2 Getting Started Guide RusMicro Scanner2 Getting Started Guide Rus
Micro Scanner2 Getting Started Guide Rus
 
Техническое описание счетчиков однофазных типа Np 06
Техническое описание счетчиков однофазных типа Np 06Техническое описание счетчиков однофазных типа Np 06
Техническое описание счетчиков однофазных типа Np 06
 
Hioki pw6001 rus
Hioki pw6001 rusHioki pw6001 rus
Hioki pw6001 rus
 
Hioki pw6001 rus
Hioki pw6001 rusHioki pw6001 rus
Hioki pw6001 rus
 
Сварог tig200,315 p-dsp_ac_dc
Сварог tig200,315 p-dsp_ac_dcСварог tig200,315 p-dsp_ac_dc
Сварог tig200,315 p-dsp_ac_dc
 
Каталог продукции ООО Харьковэнергоприбор
Каталог продукции ООО ХарьковэнергоприборКаталог продукции ООО Харьковэнергоприбор
Каталог продукции ООО Харьковэнергоприбор
 
Instrukcija ridgid-seektech-sr-20
Instrukcija ridgid-seektech-sr-20Instrukcija ridgid-seektech-sr-20
Instrukcija ridgid-seektech-sr-20
 
Split addax
Split addaxSplit addax
Split addax
 
Филин-А
Филин-АФилин-А
Филин-А
 
Vnx.su системы впрыска sandero
Vnx.su системы впрыска sanderoVnx.su системы впрыска sandero
Vnx.su системы впрыска sandero
 
Специализированная аппаратура ВЧ связи для РЗ и ПА. Отличительные особенности...
Специализированная аппаратура ВЧ связи для РЗ и ПА. Отличительные особенности...Специализированная аппаратура ВЧ связи для РЗ и ПА. Отличительные особенности...
Специализированная аппаратура ВЧ связи для РЗ и ПА. Отличительные особенности...
 
http://vnx.su/ thalia-symbol-2-diagnostika
http://vnx.su/ thalia-symbol-2-diagnostikahttp://vnx.su/ thalia-symbol-2-diagnostika
http://vnx.su/ thalia-symbol-2-diagnostika
 
NP-06 TD MME.1F.1SM-U
NP-06 TD MME.1F.1SM-UNP-06 TD MME.1F.1SM-U
NP-06 TD MME.1F.1SM-U
 
Hioki pw3198 rus
Hioki pw3198 rusHioki pw3198 rus
Hioki pw3198 rus
 
Hioki pw3198
Hioki pw3198Hioki pw3198
Hioki pw3198
 

D7c6ae90

  • 1. СВЯЗЬПРИБОР ЛИС ЛИС-М ЛИС-М+ Искатель скрытых коммуникаций РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ v 1.0
  • 2. 2
  • 3. ОГЛАВЛЕНИЕ 1 ____________________________________________4 НАЗНАЧЕНИЕ 2 _______________________________________________5 ВВЕДЕНИЕ 3 __________________________________________5 БЕЗОПАСНОСТЬ 4 ____________________________________________7 СЕРТИФИКАТ 5 ______________________________7 УСЛОВИЯ ЭКСПЛУАТАЦИИ 6 _______________________8 ТЕХНИЧЕСКИЕ ХАРАКТЕРИСТИКИ 7 ______________8 СОСТАВ ИЗДЕЛИЯ И КОМПЛЕКТ ПОСТАВКИ 8 _________________________________9 ОПИСАНИЕ КОМПЛЕКТА 8.1 ___________________________________________9 Искатель 8.2 _________________________________________10 Генератор 8.3 ____________________________10 Соединительные провода 9 _________________________11 ПРИНЦИП РАБОТЫ КОМПЛЕКТА 10 ________________________________11 ПОДГОТОВКА К РАБОТЕ 10.1 __________________________12 Замена элементов питания 11 _________________________13 ПОДКЛЮЧЕНИЕ И УПРАВЛЕНИЕ 11.1 ____________________________13 Подключение генератора 11.2 ________________________________15 Работа с искателем 12 ____________________________________________17 ИЗМЕРЕНИЯ 12.1 ____________17 Поиск проводов в потолках, стенах и полах 12.2 __________________________________________________18 Идентификация предохранителей в распределительном щите 12.3 _________________________________________________19 Обнаружение нелегальных обводов счетчиков электроэнергии 12.4 __________________________19 Отбор проводника из пучка 12.5 _______________________20 Локализация подземного кабеля 12.6 _____________________________________________21 Локализация подземного кабеля с применением внешней антенны (ЛИС-М+) 12.7 _________________22 Определение глубины залегания кабеля 12.8 _____________________________________23 Определение глубины залегания кабеля с применением внешней антенны (ЛИС-М+) 12.9 _____________________23 Поиск замыканий между жилами 12.10 _____________________24 Поиск места обрыва проводов 12.11 _25 Поиск скрытой проводки без применения генератора 13 _______________________________25 ЧИСТКА И КОНСЕРВАЦИЯ 14 _______________________25 ТРАНСПОРТИРОВКА И ХРАНЕНИЕ 15 _26 СВЕДЕНИЯ О СОДЕРЖАНИИ ДРАГОЦЕННЫХ МЕТАЛЛОВ 16 ________________________26 ГАРАНТИЙНЫЕ ОБЯЗАТЕЛЬСТВА 17 ___________________________26 СВИДЕТЕЛЬСТВО О ПРИЕМКЕ 3
  • 4. 1 НАЗНАЧЕНИЕ искатель скрытых коммуникаций ЛИС-М (+) предназначен для: 1) Поиск трассы проводов в потолках, стенах и полах; 2) Обнаружение нелегальных обводов счетчиков электроэнергии; 3) Идентификация выключателей и предохранителей; 4) Поиск трасс замкнутых и оборванных цепей; 5) Поиск трассы водопроводных труб и труб теплоснабжения; 6) Поиск отдельных жил в системе проводов и кабелей; 7) Поиск трассы кабеля, а также водопроводных труб и труб теплоснабжения в полевых условиях – для ЛИС-М+ и на глубине до 2 метров – для ЛИС-М; 8) Отбор пар в многопарном кабеле; 9) Определение глубины залегания провода. Искатель ЛИС позволяет фиксировать сигнал с частотой 26 250 ± 3 Гц и работает в комплекте с генератором ЛИС. Искатель ЛИС имеет встроенную антенну, а также может работать с внешней антенной (комплект ЛИС-М+). Применение внешней антенны значительно увеличивает чувствительность искателя и позволяет с большим удобством работать с подземными коммуникациями. Генератор ЛИС позволяет проводить измерения на кабелях без отключения электропитания до ~220 В. Электропитание искателя осуществляется от 2-х алколайновых батарей или Ni-Mh аккумуляторов типоразмера «АА». Электропитание генератора осуществляется от 4-х алколайновых батарей или Ni-Mh аккумуляторов типоразмера «АА». Индикация обнаружения трассы осуществляется визуально и звуковым способом через встроенный излучатель и внешние наушники. 4
  • 5. 2 ВВЕДЕНИЕ Благодарим Вас за покупку нашего комплекта для поиска скрытых коммуникаций ЛИС-М (+). Перед началом работы внимательно прочитайте Руководством по эксплуатации. Следуйте правилам безопасности и рекомендациями Производителя это позволит избежать ошибок при поиске коммуникаций и предотвратит возможные проблемы при использовании комплекта. В данном Руководстве текст в рамке со знаком , указывает на возможные опасности, как для пользователя, так и для комплекта. Текст, начинающийся со словом «ПРЕДУПРЕЖДЕНИЕ» указывает на ситуации, представляющие угрозу жизни или здоровью людей в случае невыполнения требований данного Руководства. Слово «ВНИМАНИЕ» указывает на ситуацию, в которой невыполнение данного Руководства грозит повреждением прибора. 3 БЕЗОПАСНОСТЬ ПРЕДУПРЕЖДЕНИЕ:  КОМПЛЕКТ ЛИС МОЖЕТ ЭКСПЛУАТИРОВАТЬСЯ ТОЛЬКО КВАЛИФИЦИРОВАННЫМИ ЛИЦАМИ, ИМЕЮЩИМИ ТРЕБУЕМУЮ ГРУППУ ДОПУСКА ДЛЯ ИЗМЕРЕНИЙ В ЭЛЕКТРИЧЕСКИХ СЕТЯХ. РАБОТА ЛИЦ БЕЗ ДОПУСКА К РАБОТЕ С КОМПЛЕКТОМ МОЖЕТ ПРИВЕСТИ К ЕГО ПОВРЕЖДЕНИЮ И СТАТЬ ИСТОЧНИКОМ СЕРЬЕЗНОЙ ОПАСНОСТИ ДЛЯ ПОЛЬЗОВАТЕЛЯ  НЕ РАЗБИРАЙТЕ ПРИБОР  НЕ ДОПУСКАЕТСЯ ЭКСПЛУАТАЦИЯ ПРИБОРА С ПОВРЕЖДЕННЫМ КОРПУСОМ, НЕИСПРАВНОГО ПОЛНОСТЬЮ ИЛИ ЧАСТИЧНО, С ПОВРЕЖДЕННОЙ ИЗОЛЯЦИЕЙ ПРОВОДОВ, А ТАКЖЕ ХРАНИВШЕГОСЯ В АГРЕССИВНЫХ УСЛОВИЯХ 5
  • 6.  НЕ ДОПУСКАЕТСЯ ЭКСПЛУАТАЦИЯ ПРИБОРА В ВЗРЫВО-, ПОЖАРООПАСНЫХ ПОМЕЩЕНИЯХ  ПЕРЕД ПОДКЛЮЧЕНИЕМ ГЕНЕРАТОРА К СЕТЕВЫМ КАБЕЛЯМ ИЛИ РОЗЕТКАМ ПРОВЕРЬТЕ НАЛИЧИЕ СЕТЕВОГО НАПРЯЖЕНИЯ И ПРИ ЕГО НАЛИЧИИ БУДЬТЕ ПРЕДЕЛЬНО ОСТОРОЖНЫ  ПРИ ПОДКЛЮЧЕНИИ ГЕНЕРАТОРА К СЕТЕВОМУ КАБЕЛЮ БЕЗ ОТКЛЮЧЕНИЯ СЕТЕВОГО НАПРЯЖЕНИЯ СЛЕДУЕТ В ПЕРВУЮ ОЧЕРЕДЬ ПОДКЛЮЧИТЬ СОЕДИНИТЕЛЬНЫЕ ПРОВОДА К ГЕНЕРАТОРУ, ДАЛЕЕ 1-ЫЙ ПРОВОД ПОДКЛЮЧИТЬ К ЗАЗЕМЛЕНЮ, А УЖЕ ПОСЛЕ ЭТОГО 2-ОЙ ПРОВОД ПОДКЛЮЧИТЬ К ИСКОМОМУ КАБЕЛЮ  НЕ ДОПУСКАЕТСЯ ОСТАВЛЯТЬ НЕ ПОДКЛЮЧЕННЫМ ОДИН ПРОВОД ГЕНЕРАТОРА ПРИ ПОДКЛЮЧЕНИИ ГЕНЕРАТОРА К СЕТЕВОМУ КАБЕЛЮ БЕЗ ОТКЛЮЧЕНИЯ СЕТЕВОГО НАПРЯЖЕНИЯ  ПРИ ЗАМЕНЕ ЭЛЕМЕНТОВ ПИТАНИЯ, ОБЯЗАТЕЛЬНО ОТКЛЮЧИТЕ ГЕНЕРАТОР ОТ ВНЕШНИХ ЦЕПЕЙ  ВЫКЛЮЧЕНИЕ ГЕНЕРАТОРА КНОПКОЙ НЕ ОТКЛЮЧАЕТ ВЫХОДНЫЕ КЛЕММЫ ОТ ВНУТРЕННИХ ЦЕПЕЙ Перед началом работы следует тщательно ознакомиться с настоящим Руководством; Прибор должен обслуживаться только лицами с соответствующей квалификацией; Ремонт может производиться только уполномоченными Сервисными центрами. 6
  • 7. 4 СЕРТИФИКАТ SVYAZPRIBOR Co Ltd 170034 Russia, Tver, Koroleva str.9 Directive RTTE 1999/5/WE on Radio Equipment and Telecommunication Terminal Equipment. Electromagnetic Compatibility EMC Directive 2004/108/WE Декларация о соответствии: РОСС RU.АЯ46.Д62614 5 УСЛОВИЯ ЭКСПЛУАТАЦИИ Комплект может эксплуатироваться: - на высоте до 2000 м над уровнем моря; - при температуре от +5 до +40 °С; - степень загрязнения воздуха – 2. ПРЕДУПРЕЖДЕНИЕ: НАРУШЕНИЕ УСЛОВИЙ ЭКСПЛУАТАЦИИ МОЖЕТ ВЫЗВАТЬ СНИЖЕНИЕ ХАРАКТЕРИСТИК ЭЛЕКТРОБЕЗОПАСНОСТИ ПРИБОРА 7
  • 8. 6 ТЕХНИЧЕСКИЕ ХАРАКТЕРИСТИКИ Искатель Активная частота: 26250 ± 3 Гц Полоса пропускания по уровню –3 дБ (не более) 150 Гц Максимально определяемая глубина залегания трассы 2 м Точность отыскания 1 см Время непрерывной работы (не менее) 20 ч Электропитание: алколайновые батареи или Ni- Mh, 2,3 А/ч аккумуляторы 2 шт. АА Степень защиты корпуса IP42 Габаритные размеры прибора 135х70х24 мм Масса прибора (включая элементы питания) 0,20 кг Габаритные размеры внешней антенны 900х200х40 мм Генератор Выходной сигнал частота: 26252 ± 1 Гц Выходная мощность 1 вт Время непрерывной работы (не менее) 20 ч Электропитание: алколайновые батареи или Ni-Mh, 2,1 А/ч аккумуляторы 4 шт. АА Степень защиты корпуса IP42 Габаритные размеры прибора (без сумки) 180х65х27 Масса прибора (без элементов питания) 0,20 кг 7 СОСТАВ ИЗДЕЛИЯ И КОМПЛЕКТ ПОСТАВКИ № Наименование Кол-во 1. Искатель ЛИС 1 2. Генератор ЛИС 1 3. Комплект проводов универсальный для подключения генератора к нагрузке 1 4. Датчик 1 5. Руководство по эксплуатации 1 6. Сумка 1 7. Приемная антенна (комплектуется только ЛИС-М+) 1 8
  • 9. 8 О ПИСАНИЕ КОМПЛЕКТА 8. 1 Искатель На лицевой панели искателя расположены: 1. Стрелка указывающая расположение датчика в корпусе прибора 2. Разъем для подключения внешнего датчика или антенны 3. индикатор уровня сигнала 4. индикатор включения искателя  н е горит – выключено  мигает – включено, элементы питания разряжены  го рит непрерывно - вк лючено 5. - кнопка включения искателя 6. индикатор включения фонового режима - кнопка включения фонового режима 7. - кнопки изменения чувствительности искателя 8 . 9 . - кнопка включения встроенного фонарика 10. разъем дл 9
  • 10. 8 .2 Генератор На лицевой панели генератора расположены: 1. выходные клеммы 2. индикатор выходной мощности генератора  н е горит – минимальная мощность  м игает – средняя  г орит непрерывно – максимальная 3. - кнопка регулировки мощности выходного сигнала 4. индикатор включения питания  н е горит – выключено  м игает – включено, элементы питания разряжены  горит непрерывно – включено 5 . - кнопка включения генератора 8 .3 Соединительные провода Комплект поставляется с универсальным набором соединительных проводов. На изолированные концы проводов могут надеваться как зажимы «Крокодил», так и зонды, поставляемые с проводами. 10
  • 11. 9 П РИНЦИП РАБОТЫ КОМПЛЕКТА Генератор ЛИС является источником характерного сигнала, подключаемым к жиле искомого кабеля. Протекающий по кабелю переменный ток создает вокруг него магнитное поле, которое индуцирует сигнал в индуктивном датчике искателя. Принятый сигнал поступает в приемное устройство искателя, где осуществляется аналоговая и цифровая обработка. Полученные результаты выводятся на светодиодный индикатор и звуковой излучатель. 10 ПОДГОТОВКА К РАБОТЕ При получении комплекта искателя распакуйте его и внешним осмотром убедитесь в отсутствии механических повреждений корпусов и элементов, расположенных на лицевых панелях искателя и генератора. Если приборы хранились при повышенной влажности или в условиях низких температур, просушите его в течение 24 ч в нормальных условиях. ВНИМАНИЕ  ВО ИЗБЕЖАНИЕ ПОВРЕЖДЕНИЯ НЕ ДОПУСКАЕТСЯ ДЛИТЕЛЬНОЕ ХРАНЕНИЕ ИСКАТЕЛЯ С УСТАНОВЛЕННЫМИ ЭЛЕМЕНТАМИ ПИТАНИЯ  НЕ ДОПУСКАЙТЕ ПОПАДАНИЯ ВОДЫ И ДРУГИХ ЖИДКОСТЕЙ ВО ВНУТРЬ КОРПУСА ПРИБОРА Установите элементы питания в соответствии с пунктом «Замена элементов питания» 11
  • 12. 1 0.1 Замена элементов питания ПРЕДУПРЕЖДЕНИЕ: ПРИ ЗАМЕНЕ ЭЛЕМЕНТОВ ПИТАНИЯ, ОБЯЗАТЕЛЬНО ОТКЛЮЧИТЕ ГЕНЕРАТОР ОТ ВНЕШНИХ ЦЕПЕЙ Электропитание искателя осуществляется от 2-х Ni-Mh аккумуляторов с напряжением 1,2 В и емкостью 2,3 А/ч или алкалайновых батарей типоразмера «АА». Откройте батарейный отсек на нижней стороне искателя и замените элементы питания, соблюдая полярность. Электропитание генератора осуществляется от 4-х Ni-Mh аккумуляторов с напряжением 1,2 В и емкостью 2,3 А/ч или алкалайновых батарей типоразмера «АА» Откройте батарейный отсек на нижней стороне генератора, открутив 1 винт, и замените элементы питания, соблюдая полярность. Включите прибор, нажав кнопку . При правильной установке элементов питания и их достаточной степени заряда свидетельствует зажигание индикатора питания. При разряде элементов питания индикатор начнет пульсировать, а при полном разряде искатель отключается. Включение и индикация разряда в генераторе и искателе организованы аналогично. 12
  • 13. 11 ПОДКЛЮЧЕНИЕ И УПРАВЛЕНИЕ 11. 1 Подключение генератора На работающем сетевом кабеле генератор испытательных сигналов может быть подключен непосредственно к жиле без отключения напряжения. ВНИМАНИЕ НЕДОПУСКАЕТСЯ ПОДКЛЮЧЕНИЕ ГЕНЕРАТОРА К КАБЕЛЮ С НАПРЯЖЕНИЕМ ВЫШЕ ~220 В ПРЕДУПРЕЖДЕНИЕ: ПРИ ПОДКЛЮЧЕНИИ ГЕНЕРАТОРА К СЕТЕВОМУ КАБЕЛЮ БЕЗ ОТКЛЮЧЕНИЯ СЕТЕВОГО НАПРЯЖЕНИЯ СЛЕДУЕТ В ПЕРВУЮ ОЧЕРЕДЬ ПОДКЛЮЧИТЬ СОЕДИНИТЕЛЬНЫЕ ПРОВОДА К ГЕНЕРАТОРУ, ДАЛЕЕ 1 ПРОВОД ПОДКЛЮЧИТЬ К ЗАЗЕМЛЕНЮ, А УЖЕ ПОСЛЕ ЭТОГО ПОДКЛЮЧИТЬ К ИСКОМОМУ КАБЕЛЮ 13
  • 14. Выходные клеммы генератора равнозначны, и при подключении можно выбирать любую клемму. Подключение генератора к кабелю: способ 1: любой вывод генератора подключить к жиле скрытой проводки, второй вывод ко второй жиле этой же скрытой проводки (например к розетке). При подключении таким способом следует учитывать что подключение к двум жилам одного провода вызывает эффект компенсации, что приводит к значительному уменьшению уровня сигнала. По этому предпочтительнее использовать способ 2 или 3. способ 2: вывод генератора подключить к жиле скрытой проводки, второй вывод к этой же жиле на дальнем конце проводки (например провод теплых полов) способ 3: вывод генератора подключить к жиле скрытой проводки, второй вывод к шине заземления (заземление в другой розетке, батарея центрального отопления, водопроводная труба). При включении генератора автоматически включается режим минимальной выходной мощности, индикатор выходной мощности не светится. В некоторых случаях описанных ниже требуется изменить выходную мощность генератора. Для увеличения нажмите один раз 14
  • 15. кнопку , индикатор начнет мигать, что соответствует средней выходной мощности. Для включения максимальной выходной мощности нажмите еще один раз кнопку, индикатор начнет светиться непрерывно – максимальная выходная мощность. При нажатии на кнопку генератор вернется в режим минимальной выходной мощности 1 1.2Работа с искателем Регулировка усиления (меньше) ил При поиске трассы установите кнопкам (больше) показания индикатора в пределах шкал В момент нажатия кнопки или на индикаторе уровня сигнала кратковременно отображается положение регулятора усиления. Размещение антенны в корпусе искателя Для точного определения трассы следует учитывать расположение датчика в корпусе прибора. Расположение показано на передней панели приемника стрелкой. Режимы поиска и определения направления При поиске скрытого кабеля в зависимости от ориентации искателя существует два метода поиска «по максимуму» и «по минимуму». 15
  • 16. Поиск по максимуму: при данном расположении датчика над центром кабеля, уровень сигнала максимален. Этот способ используется для примерного определения расположения кабеля. Поиск по минимуму: при данном расположении датчика над центром кабеля, уровень сигнала минимален. При таком способе поиска достигается наибольшая точность отыскания. Определение направления прокладки кабеля: при вращении искателя вокруг своей оси над кабелем, положение с минимальным уровнем сигнала покажет направление прокладки кабеля. 16
  • 17. 12 ИЗМЕРЕНИЯ 1 2.1 Поиск проводов в потолках, стенах и полах Подключите генератор как описано в пункте «Подключение генератора» способ 2: первый вывод к жиле скрытой проводки, второй вывод к этой же жиле на дальнем конце проводки (например к выводам провода теплого пола). Проводите поиск скрытой проводки ориентируясь по максимальному уровню сигнала. Для более точного определения местоположения трассы следует проводить поиск по минимуму. Теперь ориентируясь по минимальному уровню сигнала, определите точное расположение трассы. При невозможности подключить генератор как описано в пункте «Подключение генератора» способ. 2, можно провести поиск подключив генератор одним выводом к жиле обследуемого кабеля, вторым к заземлению, (пункт «Подключение генератора» способ 3.). Проведите поиск скрытой проводки, ориентируясь по максимальному уровню сигнала. 17
  • 18. 1 2.2 Идентификация предохранителей в распределительном щите Определите прохождение скрытой проводки до распределительного щита (пункт «Поиск проводов в потолках, стенах и полах»). Подключите генератор как описано в пункте «Подключение генератора» способ 1 первый вывод к жиле искомого кабеля, второй ко второй жиле того же кабеля. Включите генератор на минимальной мощности (при большом удалении от места подключения мощность генератора следует увеличить кнопкой ). Поднося приемник к предохранителям или выключателям определите искомый выключатель, ориентируясь по максимуму уровня сигнала. Поскольку современные предохранители, в частности выключатели дифференцированного тока, имеют внутри один или более витков провода, может оказаться, что понадобится различная ориентация приемника и повторение попыток локализации. 18
  • 19. 12.3 Обнаружение нелегальных обводов счетчиков электроэнергии Подключите генератор одним вывод к жиле обследуемого кабеля, вторым к заземлению, (пункт «Подключение генератора» способ 3.) Продвигаясь по трассе скрытой проводки, располагайте приемник как показано на рисунке. Резкое повышение уровня сигнала свидетельствует о наличии отвода. 12 .4 Отбор проводника из пучка Подключите генератор одним вывод к жиле искомого проводника, вторым к заземлению, («Подключение генератора» способ 3.). Неиспользуемые проводники следует также заземлить. Включите генератор на максимальной мощности. Подключите к искателю внешний датчик. Поочередно касаясь приемником всех проводников, определите «свой» проводник по максимальному уровню сигнала. 19
  • 20. 12.5 Локализация подземного кабеля Для поиска трассы выход генератора подключают одним проводом к жиле кабеля, другим - к штырю заземления. Штырь заземления относится на 10 - 20 м в сторону от трассы. Жилу кабеля на дальнем конце, если возможно, следует заземлить. Включите генератор. Установите максимальную мощность выходного сигнала. Включите приемник. Расположите приемник над трассой как показано на рисунке. Ориентируясь по максимальному сигналу, продвигайтесь вдоль трассы. Для более точного определения местоположения трассы следует проводить поиск по минимуму (пункт «Подключение генератора»). Теперь ориентируясь по минимальному уровню сигнала, определите точное расположение трассы. 20
  • 21. 12.6 Локализация подземного кабеля с применением внешней антенны (ЛИС-М+) Подключение генератора осуществляется, так же как и без применения внешней антенны. Описание дано в предыдущем пункте. Подключите к разъему искателя внешнюю антенну. Для удобства работы датчик расположен под углом 45°. Расположение кабеля определяется по максимуму показаний индикатора при расположении антенны как показано на рисунке (а). Уточнение расположения кабеля производится по минимуму сигнала при расположении антенны как показано на рисунке (б). Для этого необходимо расположить датчик вертикально и добиться минимальных показаний индикатора. Зависимость уровня 21
  • 22. сигнала от положения антенны над трассой и режима поиска показано на рисунке. 12 .7 Определение глубины залегания кабеля Подключите генератор: первый вывод к жиле скрытой проводки, второй вывод к этой же жиле на дальнем конце проводки (пункт «Подключение генератора» способ 2) или первый вывод к жиле искомого кабеля, второй емлению (пункт «Подключение генератора» способ 3) Определите точное расположение искомого провода (кабеля). Для определения глубины залегания, расположите прибор на поверхности стены или земли в максимуме сигнала. Установите усиление так, чтобы показания были в пределах шкалы светодиодного индикатора. Отводя прибор от стены (земли), добейтесь вдвое меньших показаний. Расстояние от прибора до 22
  • 23. 12.8 Определение глубины залегания кабеля с применением внешней антенны (ЛИС-М+) Подключите генератор как сказано в предыдущем пункте. Подключите к разъему искателя внешнюю антенну. Наилучшие результаты достигаются при работе по «минимуму» сигнала. Определите точное расположение искомого провода (кабеля). Расположите антенну вертикально над точкой прохождения трассы как показано на рисунке, вид а). Отводите антенну в сторону перпендикулярно трассе до точки, где уровень сигнала будет минимален, вид б). Расстояние между точками – hизм будет равно глубине залегания трассы - h. 12.9 Поиск замыканий между жилами Подключите генератор к любой жиле кабеля, пункт «Подключение генератора» способ 3. Включите генератор на минимальную мощность. Определите трассу проводки. Только после разметки трассы начинайте поиск КЗ. 23
  • 24. Подключите генератор между замкнутыми жилами кабеля, пункт «Подключение генератора» способ 1. Включите генератор на максимальную мощность. Продвигайтесь по размеченной трассе и наблюдайте за уровнем сигнала. В месте короткого замыкания наблюдается понижение уровня сигнала. Причем после места КЗ сигнал будет прослушиваться, но с меньшим уровнем. Для уточнения места КЗ следует подключить генератор на дальнем конце и повторить поиск. Результат должен повторится! 12.1 0 Поиск места обрыва проводов Подключите генератор как описано в пункте «Подключение генератора» способ 3 первый вывод к жиле искомого кабеля, второй к заземлению. Включите генератор на минимальной мощности (при большом удалении от места подключения мощность генератора следует увеличить кнопкой ). Для обнаружения обрыва жил кабеля необходимо заземлить все жилы кроме подключенной к генератору, а также все жилы на дальнем конце кабеля. К искателю подключите внешний датчик. Продвигайтесь по трассе по максимуму сигнала, в месте обрыва сигнал уменьшается. 24
  • 25. 12.1 1 Поиск скрытой проводки без применения генератора Включите на искателе широкополосный режим, нажав кнопку . Проводите поиск скрытой проводки находящейся под напряжением ориентируясь по максимальному уровню сигнала. Наилучшие результаты достигаются при подключении нагрузки к искомой проводке. Также можно отыскать любые шумящие трассы. При данном способе поиска уровень сигнала зависит от ориентации датчика относительно искомого кабеля. 13 ЧИ СТКА И КОНСЕРВАЦИЯ Корпуса передатчика и приемника можно протирать мягкой влажной фланелью с использованием общедоступных моющих средств. Нельзя пользоваться растворителями и чистящими средствами, которые могут поцарапать корпус (порошки, пасты и так далее). Электронная схема прибора не требует консервации. 14 ТР АНСПОРТИРОВКА И ХРАНЕНИЕ Транспортирование комплектов искателя скрытых коммуникаций производится в упакованном виде железнодорожным или автомобильным транспортом в крытых вагонах или закрытых автомашинах в соответствии с правилами перевозки грузов, действующих на данном виде транспорта. В помещениях для хранения не должно быть паров кислот и щелочей, агрессивных газов и других вредных примесей, вызывающих коррозию. ПЕРЕД ДЛИТЕЛЬНЫМ ХРАНЕНИЕМ, ВО ИЗБЕЖАНИЕ ПОВРЕЖДЕНИЯ БАТАРЕИ, ИХ СЛЕДУЕТ ВЫНУТЬ ИЗ ПРИБОРОВ. 25
  • 26. 26 15 СВ ЕДЕНИЯ О СОДЕРЖАНИИ ДРАГОЦЕННЫХ МЕТАЛЛОВ Драгоценных металлов прибор не содержит. 16 ГА РАНТИЙНЫЕ ОБЯЗАТЕЛЬСТВА Завод-изготовитель гарантирует работоспособность искателя скрытых коммуникаций при соблюдении условии эксплуатации, хранения, транспортирования, указанных в настоящем техническом описании. Гарантийный срок эксплуатации - 12 месяцев с момента продажи прибора. Гарантийные обязательства не распространяются на батареи. В случае выхода из строя прибора потребителем должно быть составлено сопроводительное письмо с указанием неисправности и подробным обратным адресом с указанием контактных телефонов. Письмо вместе с комплектом высылается предприятию- изготовителю по адресу: 170030, г. Тверь, ул. Королева, д. 9, ООО «СВЯЗЬПРИБОР» тел.: (4822) 42-54-91, 72-52-76, 51-50-72 факс: (4822) 42-54-91 E-mail: support@svpribor.ru http://www.svpribor.ru 17 СВ ИДЕТЕЛЬСТВО О ПРИЕМКЕ Искатель скрытых коммуникаций ЛИС, заводской № ______________ соответствует ТУ 4221-021-40720371-12 и признан годным к эксплуатации. Представитель завода __________________