HeartRec
Holter ECG Smallest in Size, Perfect in Performance,excellent technical characteristics,HeartRec elaborately designed to ensure the best possible experience for the patient and the user.
It is advanced HOLTER. sophisticated software system and elaborate HOLTER recorder, Heartrec as an integrate system combines both 3-channel and 12-lead recording and analyzing in one, meets all high-end performance and fiscal responsibility
👉 Chennai Sexy Aunty’s WhatsApp Number 👉📞 7427069034 👉📞 Just📲 Call Ruhi Colle...
Heartrec Holter ECG 72hours..more
1. Smallest in Size, Perfect in Performance
In addition to excellent technical
characteristics, HeartRec was elaborately
designed to ensure the best possible
experience for the patient and the user.
Specifications
▲ Channels: Two Work Modes
12-lead / 3-Channel Switchable by Changing Patient Cable
10-Wire Cable: 12-Lead: I, II, III, aVR, aVL, aVF, V1 - V6 5Wire or 7-Wire: Standard 3 Channels
▲ Program able Recording:
Time: 24h-72h, up to 7 days for 3ch
Sampling Rate: 128—1024/ch/s up to
10,000/ch/s Resolution: 12-16 bits
Independent Pace Maker Channel
▲ LCD Display:
Real Time ECG View
Instruction Programming
Multi-Language Selectable
▲ High Quality Recording:
Frequency Response:
0.05~60Hz CMMR: >80dB
Input Impedance: >5MΩ
▲ Double Work Modes in Data Access:
Removable SD Card: 512MB/1GB/
2GB USB connector
▲ Low Power Consuption:
One AAA Battery: up to 7 days for 3-Channel
▲ Compact Size & Light Weight:
72mm×53mm×16mm (2.8"×2.0"×0.63")
48g (1.7oz.), battery not included
Meditech Equipment Co., Ltd (Meditech Group)
Address: Nanjing Road No.100, Qingdao, Shandong Province, P. R. China
China Tel: 86-532-85832673 85820563
Fax: 86-532-85832155
Email: sales@meditech.com.cn sales@meditech.cn
USA Tel: +01 2399355088
UK Tel: +44 2081233737
Web: www.meditech.com.cn
2. Heartrec an advanced HOLTER developing history. Sophisticated software system
and elaborate HOLTER recorder, Heartrec as an integrate system combines both 3channel and 12-lead recording and analyzing in one, meets all high-end performance and
fiscal responsibility.
Automatic template Classification:
Color-enhanced,
beat-by-beat
Arrhythmiagraph
display showing heart rate and detected Normal, VE,
SVE, and Unknown beats. Quickly access any
displayed beat and view it
Automatic Atrial Fibrillation Analysis with Assistant Tools
On a 12-lead ECG strip. Sophisticated Templates
Editor:
Three advanced tools based on beats
superimposition
Fibrillation Analysis
Fibrillation Trend
Obstructive Sleep Apnea Syndrome
Analysis (Option)
Heart Rate Variability (HRV): With time-domain, frequency-domain and
nonlinear analysis Either 5min, 1 hour or 24 hours available
DEMIX
RR-HIST
BIRDVIEW
Tools for 12-Lead ST-T Analysis
With the finest tools to measure and analyze ST segment
episodes, the system is easy-using in myocardial ischemia
positioning depending on either event or entire period.
HRV HISH
HRV Frequency
Heart Rate Turbulence (VE
Chaos, HRT) Analysis (Option)
depression, elevation and slope, and combining ST-T trend,
superimposition, and scanning com partition to edit any ST
ST Segment Setting
12-Lead ST Trend with ECG Scanning
12-Lead T Trend with ECG Scanning
Comprehensive pacemaker report.
Pacemaker Analysis
The feature includes algorithms for a wide range of
pacer types including WI, AAI and DDD, etc., produces a
VVI AAI DDD Modes
VVI AAI DDD Trend
VVI AAI DDD Statistics Table
T wave Alterance Analysis
(Option) : A
Significant Index for Analyzing
Malignant
Arrhythmia and Sudden Cardiac
Death
QT dispersion
Bird View (Option) Including VCG
and VLP for Rest
ECG