TECH                          HNICAL BID           SO R PH OVO AIC          OLAR HOTO OLTA       ...
          CONT       TENT          1.           SY           YSTEM DESIG                     GN .............................
          1.  SY         YSTEM D               DESIGN      i.   CUS           STOMER R                  REQUIREM          ...
        vi. DES          SIGN SUMMARY        Total Installed capac                        city                        : 20...
       2.  SY         YSTEM D               DESCRIPT                      TION      i.         Solar PV G                 ...
                   3. SYSTEM                    M CONFIG                           GURATIO                                ...
       Modul        le Mountin                 ng Structu                          ures:       The  mo          odule  mou...
       Delta G          Grid Conn                  nect Invert                            ter:      The  5  k Delta  Grid ...
     Monitoring Syst                  tem:      Monito         oring  system is  mainly  used  to  mo                     ...
     Earthi         ing & Lightning Prot                            tection:      Earthing:  The  array structure  o the  ...
       4.  BI         ILL OF M                MATERIA                      AL       The brie           ef bill of mat     ...
Upcoming SlideShare
Loading in …5
×

08.20.24 kw.ongrid datasheet usl_06.05.2012

213 views
184 views

Published on

Published in: Technology, Business
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
213
On SlideShare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
8
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

08.20.24 kw.ongrid datasheet usl_06.05.2012

  1. 1.    TECH HNICAL BID   SO R PH OVO AIC OLAR HOTO OLTA  SYST S TEM PRO OSAL OPO L  SYST TEM PROPOSAL L FOR 20 KWP  GRID C 0.24  P CONNECT TED SOLAR  L PV V SYSTEM M                  CUST TOMER:   
  2. 2.        CONT TENT       1.    SY YSTEM DESIG GN ............................... ................... ................... ............................................   2.    SY YSTEM DESC CRIPTION  ...................... ................... ..............................................................   3.    SY YSTEM  CONF FIGURATION N  ................ ...................................................... ................... .........   4.    BI ILL OF MATE ERIAL ............................ ................... ................... ............................................               System P Proposal –  Page 2 of 11
  3. 3.        1.  SY YSTEM D DESIGN   i.   CUS STOMER R REQUIREM MENT    The  Customer  wou like  to  in uld  nstall  20.24 kWp  Grid  c connected  S Solar  Power  Plant  in region  of  South IIndia.    ii.  DES SIGN ASSU UMPTIONS S    Module Facing                                          : True e  e South   Module Tilt angle                                     : 14° e   Type  of f System                                         : Grid Connected System     iii. PRO OPOSED TECHNOLOG GY     The  on‐ ‐grid  solar  photovoltaic  power  plant to be  proposed  shall  b t  be consisting  of  Poly  crys stalline  solar  modules  with fixed  tilt  a m h  ting  systems and  the  solar  inverters  shall  be  of  grid  angle  mount s  interact tive  central t type.    iv. BEN NEFITS OF PROPOSED TECHNO OLOGY     The ben nefit  of cryst talline  technology  as com mpared  to other  existing technologie is as fo llo g  es  ows;     ‐  It occupi less area when comp   ies  pared  to other  thin film  technologies   ‐  Proven t   technology  o over years   rials  to support  high volu ‐  Abundan semiconductor  mater   nt  ume  product tion  and  demand d.  oduction  facilities  throug ‐  High volumes  of pro   ghout  world  v.   ENERGY SIMU ULATION R RESULT      Based  o the  above  inputs  &  assumption,  an  energy simulation  h been  carried  out  an the  on  a has  nd  results f for the same e are provide below.  ed  System P Proposal –  Page 3 of 11
  4. 4.      vi. DES SIGN SUMMARY     Total Installed capac city : 20.2 Kwp 24  PV Modu ule : 230W Crystalline Modules (K Wp KL230) Total Nu umber of Mod dules : 88 N Numbers String In nverter : 5 kW W  Total Nu umber of Inve erters : 4 No os.  Approx yearly genera ation / KWp : 1752 kwh /kwp / year 2.0 p rox Yearly generation ** Appr : 35.4 MWh/ann 46 num** Module T angle Tilt : 14 D Deg Module orientation : True South e  Area req quired for mo odule installat tion : 150 Sq.mtrs.    ** Note e:  1.  The above value es are indicative e for the location n based on the historical radiatio on data. The actu ual data may var ry  depending on th he site condition ns.  System P Proposal –  Page 4 of 11
  5. 5.     2.  SY YSTEM D DESCRIPT TION   i.         Solar PV G Grid Conne ected Syste em   A   grid   connected   system   is   connected   to   a   large   independe ent   grid   (ty ypically   the   public  city   grid)   an feeds   po electric nd   ower   into  t he  grid.   Th is  a  form of   decentralized   ele his   m   ectricity  generat tion.  In  the case  of  re e  esidential  or building  m r  mounted  grid connected PV  system the  d  d  ms,  electric demand  of  the  build city  ding  is  met  b the  PV  sy by  ystem.  Only the  excess  is  fed  into  t he  grid  when  t there  is  an  excess.  The  f e feeding  of  e electricity  int the  grid  r to  requires  the  transformat tion  of  DC into o AC by a spe ecial, grid‐co ontrolled  inv verter.    A grid‐t inverter  o a (GTI)  is  a special  ty of  Invert (electrica that  is  us in a rene tie  or  ype  ter  al)  sed  ewable  energy  power  syst tem  to  conv vert  direct  c current  into  alternating  current  an feed  it  in the  nd  nto  utility  g grid.  The  technical  nam for  a  grid me  d‐tie  inverte er  is  "grid‐interactive   in nverter".  The may  ey  also  be called  syn e  nchronous  in nverters.  Gr rid‐interactiv inverters typically  cannot  be  u ve  s  c used  in  standalone  applicat tions  where  utility powe is not available.  er  The Delta Grid Tie S Solar  Inverte is designed to convert  solar  electric  (photovoltaic  or PV) p er  d  power   into  uti ility‐grade  electricity  tha can  be us by  the  h at  sed  home  or  sold to the  loca power  com d  al  mpany.  In  orde er  to  operat te,  the  inver rter  must  h have  grid  po ower  availab ble  and  connected.  It  w not  will  provide backup  po e  ower  if  the  AC  grid  fails.   The  invert will  automatically  sy A ter  ynchronize  it tself  to  grid. Th he inverter  is s provided w with the isola ation transfo ormer  internally  with basic  insulation.   System P Proposal –  Page 5 of 11
  6. 6.         3. SYSTEM M CONFIG GURATIO ON   The maj jor compone ents  of the p proposed  po ower  plant ar re as follows s:    Sl. No.  Item m  Description  1  Module  Cr rystalline sola ar modules ea ach of  230 W Wp  2  Structure  Fixed Mountinng  3  Inverter  String inverter of 5Kw      4  Monitoring g System  Central l Monitoring  system      DC Combiner Box (DCCB)  5  Junction bo ox  AC Dist tribution Box (ACDB)  6  Cables  PVC Cu Cables P s      Accessories fo cable inter A or rconnection & 7  Accessories s  installa ation kit & co onduits  8  Lightning  Lightninng  Protectionn Units     Solar P PV Module es:    Solar  ce produce  direct  curre electricit from  light which  can be  used  to power  equi ells  ent  ty  t,  n  ipment  or   to   r recharge   a   battery.   Ce require  protection  from   the  e ells   t   and  are  usually  environment package behind  a  glass  sheet.  W ed  tightly  b When  more  power  is  re equired  than a  single  cell   can  n  deliver,  cells  are  electrically  co gether  to  form  photovoltaic  module or  solar  panels.  onnected  tog es,  A  phot ovoltaic   mo packaged   interconnected   assembly of  photovoltaic   cells,  which  odule  is  a  p y   convert sunlight  in electrical  power.  The ts  nto  e cells  are h hermitically s sealed  betwe glass  an back  een  nd  cover  (T Tedlar) to pr rotect them  from harsh  environmen nts.  The det tail technical specificatio of both t l  ons  types  of mod dules  are pro ovided  below w.      Technical  Specifica ations  for Cr rystalline  Mo odules  – As per KL 230 s specs  System P Proposal –  Page 6 of 11
  7. 7.     Modul le Mountin ng Structu ures:    The  mo odule  mount ting  structur is  designe for  holding  suitable number  of  modules  in series.  re  ed  dule  mounti ng  structure is  of  Mild Steel    of  s The  frames  and  leg assemblies of  the  mod g  s  es  d  suitable  sections of  Angle,  Channel,  T s   Tubes  or  any other  sec y  cti ons  confo orming   to  IS S:2062  to  me the  eet  design  criteria.  All  hardware  c considered  for  fastening modules  w g  with  this  stru ucture  are  o very  of  ainless  Steel (SS304).  Th module mounting  st good  quality  of  Sta l  he  tructure  is  d designed  in such  a  way  tha it  will  occupy  minimum  space  w at  without  sacrificing  the  o output  from m SPV  panels  at  the  same time it will wi ithstand  severe  wind spe eed up to a maximum  120 kmph.    Technical  S Specification – Module  M n  Mounting  St tructures  Mat terial  MS   Ove erall  dimensi ion  As pe er design    Coa ating  Powd der Coated  fo or MS  Win nd rating  120 k km/hr  Tilt angle  Fixed angle, depe ends  on the s site latitude Foundation  PCC for roof top f fixing  Fixin ng type  SS 304 fasteners   Junction Boxes:    The  jun nction  boxes s  are  of  dust,  vermin,  and  waterp proof   and  m made  of  The ermo  Plastic c.    The  termina will  be co als  onnected  to copper  bus ‐bar  arrange ement  of  pr roper  sizes.  The junction boxes  T n  will  hav ve  suitable   cable  entry y  points  fitt ted  with  cable  glands  of  appropriate  sizes  fo or  both  incomin and outgo ng  oing cables.   Technical  Specification  – Ju unction  Boxe es  Mat terial  Therm moplastic  Type  Dust, Vermin & W Water  proof  Har rdware  SS 304  Cab ble Gland  Therm moplastic  Prot tection  IP 65 System P Proposal –  Page 7 of 11
  8. 8.     Delta G Grid Conn nect Invert ter:   The  5  k Delta  Grid  Tie  Solar  Inverters  So kW  olivia  5.0  is being  used in  this  proje to  conve DC  ect  ert   power  i into AC and also to expo ort the gener rated  power r into public grid.    The Del Grid Tie S lta  Solar  Inverte is designe to convert solar  electric  (photovo er  ed  t  oltaic  or  PV) power  into  uti ility‐grade  electricity  tha can  be  us by  the  h at  sed  home  or  sold to the  loca power  com d  al  mpany.  In  orde er  to  operat te,  the  inver rter  must  h have  grid  po ower  availab ble  and  connected.  It  w not  will  provide backup  po e  ower  if  the  A grid  fails. The  invert will  auto AC  .   ter  omatically  sy ynchronize  it tself  to  grid.  Th inverter   is  provided  with  the  is he  solation  tran nsformer   int ternally  with  basic  insu ulation.  tput  of the inverter  will  be single ph The out hase 230V & with 50Hz frequency.    The  solar  inverter  from  Delta  h a  peak  e f has  efficiency  of 96.0%,  so it t rightfully  o occupies  first  place  among  inverters  with transform w mer.  The ele egant  and co ompact  desig of the  casing  and low noise  gn  w  charact teristics  of the  Solivia  5. makes  the solar  inv .0  ese  verters  from  Delta  look  good even in living  areas.   System P Proposal –  Page 8 of 11
  9. 9.   Monitoring Syst tem:   Monito oring  system is  mainly  used  to  mo ms  onitor  the  performance of  the  Inve erter,  energy yield,  y  rature,  etc.  At additiona temper al cost the sys stem at optio on of custom mer it can  pro ovide an  ext tremely  flexible interface  to  facilitate   PC‐  base inverter monitoring and  contro via  Ethern e  e  ed  ol  net,  or  Interne et connections.  Industr ry‐Leading  Features  and d Performance:   • Inverter   mo onitoring   pa arameters   in nclude:   ene ergy   yield,   p power,   array voltages,  array  y   currents,  AC C parameters,  and temp peratures.   Field‐Pr roven  Reliab bility:   • Enhanced  remote‐moni itoring   capa abilities  enab the  colle ble  ection  and  a analysis  of  c critical  data needed to facilitate  increased power  syste reliability d  em  y.  Installe Friendly:  er   • A  front‐mounted   LCD   display   pro ovides   visua confirmation   of   all   critical   operating  al   parameters s.  • Compact  ea asy‐to‐install  package  with readily‐ac ccessible  ele ectrical  conn nections.   Unmatc ched  Applica ations  Flexib bility:   • Data logger  and display‐enabled  configurations are available.    Cables s:   The  size of  the  cab e  bles  between array  inter n  rconnections s,  array  to junction  box xes,  junction  boxes  to Char rge controlle etc is so se er  elected  to ke eep the volta drop and age  d losses to t he minimum m.  Technical  S Specification  – Cables  Type  PV Ins sulated,  sheath & UV resistance  Mat terial  Copper  Volt tage  Max. 1100V  Test t Voltage  650V/ /1.1V  Tem mperature  10 – 7 70 °C  Colo our  Red/ Black / Gree en   The  bright  anneale 99.97%  pure  bare  copper  conduc ed  ctors  that  offer  low  con nductor  resistance,  esult  in  lowe heating  th they  re er  hereby  incre ease  in  life  and  savings in  power  co a onsumption.  These  wires  a are  insulated with  a  sp d   pecial  grade e  PVC  comp pound   formu ulated   and   manufactur red   in ‐  house.  The skin coloration  offers high insul lation  resista ance  and lon ng life.       System P Proposal –  Page 9 of 11
  10. 10.   Earthi ing & Lightning Prot tection:   Earthing:  The  array structure  o the  PV  yard  will  be  gr y  of  rounded  pro operly  using  adequate  n number  of earth hing  kits. All metal  casin / shielding of the plan shall  be th ng  g  nt  horoughly  grounded  to  ensure  safety o of the power plant.  r    rovided  with lightning  & over  voltage  protectio The  Lightnin The  SPV  Power  Plan shall  be  pr ng:  nt  h  &  on.  main  aim  in  this  protection  sh be  to  re hall  educe  the  ov voltage to  a  tolerab value  be ver  ble  efore  it  reaches the  PV  or other  sub  sy s  ystem  comp ponents.  The source  of over  voltage can  be  lightning,  e  e  atmosp phere   distur rbances   etc Metal   ox c.   xide   variasto ors   shall   be provided   inside   the   Array  e   Combin Boxes.  In  addition  suitable  SPD also  sha be  provid ner  I D’s  all  ded  in  the  Inverter  to  protect  the inve erter  from o over voltage. .  System P Proposal –  Page 1 of 11 10
  11. 11.     4.  BI ILL OF M MATERIA AL    The brie ef bill of mat terial  is prov vided  below as ready ref ference.    Sl.No.  Descript tion  Qu uantity  1  230W Wp Crystalline  Modules  88 8 Nos.  2  Mou unting  struct tures  As required  3  Soliv via 5.0 string g inverter  4 Nos.  4  Mon nitoring  Syst tem  1 Set  1 5  Earthing  & lightn ning  protect tion  As required  6  Junc ction  boxes  As required  7  Cables  As required    8  Acce essories  1 Set  1  System P Proposal –  Page 1 of 11 11

×