<ul><li>DIRECT SENSING </li></ul><ul><li>SAMPLING </li></ul><ul><li>INSTALLATION </li></ul><ul><li>INJECTIONS </li></ul>ZE...
The Total System MIP DIRECT SENSING
What is the Membrane Interface Probe?  The  Membrane Interface Probe  (MIP) is rapid, high-resolution field screening tech...
THE  MIP PROBE DIRECT SENSING EC  Dipole Membrane Heater Block
THE  MIP TRUNKLINE DIRECT SENSING
The  System Components  DIRECT SENSING
FID PID ECD DIRECT SENSING
MIP Detection Limits DIRECT SENSING MIP DETECTORS Contaminates  Detection Limit Carrier Gas PID BTEX 1 PPM Nitrogen, Heliu...
The MIP Carrier Vehicle  Rods Generator DIRECT SENSING
Production rates:  150’ to 300’ per day. <ul><li>The production rate of the MIP is affected by : </li></ul><ul><li>the num...
MIP LOGGING DIRECT SENSING
Pre Log Response DIRECT SENSING
Example of a Microsoft  Excel Spreadsheet graphically displaying FID/PID/ECD and Conductivity Logs.  DIRECT SENSING
Post Log Response DIRECT SENSING
The Gator DIRECT SENSING
Gator In Action DIRECT SENSING
New and Improved DIRECT SENSING
DIRECT SENSING Heated Trunkline
CPT/MIP DIRECT SENSING
CPT/MIP CPT is ( Cone Penetration Testing )  commonly used to determine the subsurface stratigraphy in-situ and to estimat...
CPT/MIP ZEBRA ENVIRONMENTAL  CPT/MIP
CPT/MIP ZEBRA ENVIRONMENTAL  CPT/MIP
CPT/MIP Unit ZEBRA ENVIRONMENTAL  CPT/MIP
CPT/MIP Anchoring  ZEBRA ENVIRONMENTAL  CPT/MIP
CPT Response Graph Sleeve Friction Tip Pressure Lithology Description Friction Ratio Pore Pressure ZEBRA ENVIRONMENTAL  CP...
CPT/MIP ZEBRA ENVIRONMENTAL  CPT/MIP
DATA DATA INTEGRATION
SHAREPOINT WEBSITE FOR DATA SHARING DATA INTEGRATION
DATA INTEGRATION Remediation System Tracking (Multiple Mobilizations 2006 2008 2009
Cross-section from a 2D ECD Fence Slice.  Installed MW overlay ECD Background Slice Sampling Event Data Lithology Overlay ...
Using 3D modeling software, we can generate true 3D Solid Models.  This  Plan View  model was created using ECD data from ...
3D ECD Fence Model DATA INTEGRATION
3D ECD Solid Plume Model DATA INTEGRATION
3D Solid Model with Surface Objects DATA INTEGRATION
1-800-PROBE-IT www.TeamZEBRA.com ZEBRA Environmental Corporation 2010 For more information about the  Membrane Interface P...
New  HPT Hydraulic Profiling Tool (HPT)
New direct push technologies <ul><li>HPT Logging </li></ul><ul><li>Rhode Island </li></ul>Hydraulic Profiling Tool (HPT)
Hydraulic Profiling Tool (HPT)
Hydraulic Profiling Tool (HPT) Hydraulic Profiling Tool (HPT)
<ul><li>Advance probe at constant rate </li></ul><ul><li>Inject water at low flow rate </li></ul><ul><li>Measure formation...
Hydraulic Profiling Tool (HPT)
Depth SWL = Depth – Static Pressure 52ft – 21psi = 31ft 21psi 52ft Static Pressure Flow = 0 ROP = 0 Dissipation Test
SWL = Depth – Static Pressure Hydraulic Profiling Tool (HPT)
31 ft DPT Injection HPT SOLUTIONS Injection Wells MW Wells
HPT VA SITE  Case Study - HPT VA Site Hydraulic Profiling Tool (HPT)
Flow – Zero Pressure – High EC – Sand Case Study - HPT VA Site
Case Study - HPT VA Site
DAKOTA - UVOST/LIF UVOST/LIF
UVOST/LIF
UVOST/LIF
UVOST/LIF
UVOST/LIF
UVOST/LIF
UVOST/LIF
UVOST/LIF
UVOST/LIF
UVOST/LIF
UVOST/LIF
UVOST/LIF
UVOST/LIF
UVOST/LIF
UVOST/LIF
UVOST/LIF
UVOST/LIF
1-800-PROBE-IT www.TeamZEBRA.com ZEBRA Environmental Corporation For more information about the  Membrane Interface Probe:...
Upcoming SlideShare
Loading in …5
×

Zebra Direct Sensing MIP-CPT-HPT-LIF

870 views

Published on

All

Published in: Technology, Education
  • Be the first to comment

  • Be the first to like this

Zebra Direct Sensing MIP-CPT-HPT-LIF

  1. 1. <ul><li>DIRECT SENSING </li></ul><ul><li>SAMPLING </li></ul><ul><li>INSTALLATION </li></ul><ul><li>INJECTIONS </li></ul>ZEBRA ENVIRONMENTAL DIRECT SENSING
  2. 2. The Total System MIP DIRECT SENSING
  3. 3. What is the Membrane Interface Probe? The Membrane Interface Probe (MIP) is rapid, high-resolution field screening technology that provides information about relative concentrations of VOCs in the subsurface, and the Electrical Conductivity of the soil. <ul><li>The MIP uses a thin film fluorocarbon polymer membrane approx. 6.35mm in diameter which stays in direct contact with the soil during MIP logging. </li></ul><ul><li>The thin film membrane is impregnated into a stainless steel screen which serves as a rigid support for the fluorocarbon polymer. </li></ul><ul><li>The down-hole, permeable membrane serves as an interface to a detector at the surface. </li></ul><ul><li>Volatiles in the subsurface are getting transferred across the membrane and partition into a stream of carrier gas where they are swept to the detector. The membrane is heated in order to facilitate VOC transfer and self-cleaning. </li></ul>DIRECT SENSING
  4. 4. THE MIP PROBE DIRECT SENSING EC Dipole Membrane Heater Block
  5. 5. THE MIP TRUNKLINE DIRECT SENSING
  6. 6. The System Components DIRECT SENSING
  7. 7. FID PID ECD DIRECT SENSING
  8. 8. MIP Detection Limits DIRECT SENSING MIP DETECTORS Contaminates Detection Limit Carrier Gas PID BTEX 1 PPM Nitrogen, Helium FID Methane, Butane NA Nitrogen, Helium ECD Chlorinateds 250PPB Nitrogen
  9. 9. The MIP Carrier Vehicle Rods Generator DIRECT SENSING
  10. 10. Production rates: 150’ to 300’ per day. <ul><li>The production rate of the MIP is affected by : </li></ul><ul><li>the number of logging locations </li></ul><ul><li>the depth of logging </li></ul><ul><li>subsurface conditions </li></ul><ul><li>access restrictions </li></ul><ul><li>probe hole abandonment requirements </li></ul><ul><li>weather </li></ul>DIRECT SENSING
  11. 11. MIP LOGGING DIRECT SENSING
  12. 12. Pre Log Response DIRECT SENSING
  13. 13. Example of a Microsoft Excel Spreadsheet graphically displaying FID/PID/ECD and Conductivity Logs. DIRECT SENSING
  14. 14. Post Log Response DIRECT SENSING
  15. 15. The Gator DIRECT SENSING
  16. 16. Gator In Action DIRECT SENSING
  17. 17. New and Improved DIRECT SENSING
  18. 18. DIRECT SENSING Heated Trunkline
  19. 19. CPT/MIP DIRECT SENSING
  20. 20. CPT/MIP CPT is ( Cone Penetration Testing ) commonly used to determine the subsurface stratigraphy in-situ and to estimate geotechnical parameters of the materials present in the subsurface. <ul><li>Collect real time physical descriptions </li></ul><ul><li>Collect physical properties of the soil matrix </li></ul><ul><li>Tag a confining layer </li></ul><ul><li>Cost savings over more traditional boring and sampling methods </li></ul>DIRECT SENSING Advantages : Disadvantages: <ul><li>Must be pushed </li></ul>
  21. 21. CPT/MIP ZEBRA ENVIRONMENTAL CPT/MIP
  22. 22. CPT/MIP ZEBRA ENVIRONMENTAL CPT/MIP
  23. 23. CPT/MIP Unit ZEBRA ENVIRONMENTAL CPT/MIP
  24. 24. CPT/MIP Anchoring ZEBRA ENVIRONMENTAL CPT/MIP
  25. 25. CPT Response Graph Sleeve Friction Tip Pressure Lithology Description Friction Ratio Pore Pressure ZEBRA ENVIRONMENTAL CPT/MIP
  26. 26. CPT/MIP ZEBRA ENVIRONMENTAL CPT/MIP
  27. 27. DATA DATA INTEGRATION
  28. 28. SHAREPOINT WEBSITE FOR DATA SHARING DATA INTEGRATION
  29. 29. DATA INTEGRATION Remediation System Tracking (Multiple Mobilizations 2006 2008 2009
  30. 30. Cross-section from a 2D ECD Fence Slice. Installed MW overlay ECD Background Slice Sampling Event Data Lithology Overlay ECD Graph Overlay DATA INTEGRATION
  31. 31. Using 3D modeling software, we can generate true 3D Solid Models. This Plan View model was created using ECD data from a recent MIP project . Any orientation can be displayed and cross-sections or fence diagrams can be created. DATA INTEGRATION
  32. 32. 3D ECD Fence Model DATA INTEGRATION
  33. 33. 3D ECD Solid Plume Model DATA INTEGRATION
  34. 34. 3D Solid Model with Surface Objects DATA INTEGRATION
  35. 35. 1-800-PROBE-IT www.TeamZEBRA.com ZEBRA Environmental Corporation 2010 For more information about the Membrane Interface Probe: MIP DIRECT SENSING
  36. 36. New HPT Hydraulic Profiling Tool (HPT)
  37. 37. New direct push technologies <ul><li>HPT Logging </li></ul><ul><li>Rhode Island </li></ul>Hydraulic Profiling Tool (HPT)
  38. 38. Hydraulic Profiling Tool (HPT)
  39. 39. Hydraulic Profiling Tool (HPT) Hydraulic Profiling Tool (HPT)
  40. 40. <ul><li>Advance probe at constant rate </li></ul><ul><li>Inject water at low flow rate </li></ul><ul><li>Measure formation pressure response </li></ul>2 cm/sec Hydraulic Profiling Tool (HPT)
  41. 41. Hydraulic Profiling Tool (HPT)
  42. 42. Depth SWL = Depth – Static Pressure 52ft – 21psi = 31ft 21psi 52ft Static Pressure Flow = 0 ROP = 0 Dissipation Test
  43. 43. SWL = Depth – Static Pressure Hydraulic Profiling Tool (HPT)
  44. 44. 31 ft DPT Injection HPT SOLUTIONS Injection Wells MW Wells
  45. 45. HPT VA SITE Case Study - HPT VA Site Hydraulic Profiling Tool (HPT)
  46. 46. Flow – Zero Pressure – High EC – Sand Case Study - HPT VA Site
  47. 47. Case Study - HPT VA Site
  48. 48. DAKOTA - UVOST/LIF UVOST/LIF
  49. 49. UVOST/LIF
  50. 50. UVOST/LIF
  51. 51. UVOST/LIF
  52. 52. UVOST/LIF
  53. 53. UVOST/LIF
  54. 54. UVOST/LIF
  55. 55. UVOST/LIF
  56. 56. UVOST/LIF
  57. 57. UVOST/LIF
  58. 58. UVOST/LIF
  59. 59. UVOST/LIF
  60. 60. UVOST/LIF
  61. 61. UVOST/LIF
  62. 62. UVOST/LIF
  63. 63. UVOST/LIF
  64. 64. UVOST/LIF
  65. 65. 1-800-PROBE-IT www.TeamZEBRA.com ZEBRA Environmental Corporation For more information about the Membrane Interface Probe: ZEBRA DIRECT SENSING

×