Sun sparc enterprise t5140 and t5240 servers technical presentation

  1. 1. Sun SPARC EnterpriseT5140 and T5240Rack ServersTechnical Training Course<Name><Job Title>Sun Microsystems, Inc. 1
  2. 2. UltraSPARC T2: • Up to 8 cores @1.2GHz or 1.4GHzTrueSystem On a Chip • Up to 64 threads per CPU • Up to 16 FB-DIMMs, 4 memory controllers FB DIMM FB DIMM FB DIMM FB DIMM > Up to 64GB memory (4GB DIMMs) > 2.5x memory BW of UltraSPARC T1 FB DIMM FB DIMM FB DIMM FB DIMM • 8 x fully pipelined Floating Point units / core, 1 per core MCU MCU MCU MCU • Dual 10Gbit Ethernet and PCI-E integrated onto chip L2$ L2$ L2$ L2$ L2$ L2$ L2$ L2$ • 4MB L2 (8 banks) 16 way associative Full Cross Bar • Enhanced MAU/Security co-processor C0 C1 C2 C3 C4 C5 C6 C7 per core FPU FPU FPU FPU FPU FPU FPU FPU MAU MAU MAU MAU MAU MAU MAU MAU > DES, 3DES, AES, RC4, SHA1, DMA Sub-System SHA256, MD5, RSA to 2048 key, ECC,CRC32 NIU Sys I/F • Advanced Power saving features (E-net+) Buffer Switch Core PCI-E • 65nm process technology Power ~95W <1.5W/thread x8 @2.5GHz 2x 10GE Ethernet 4GBytes/s bi-directional Sun Internal and Approved Partners Only 2
  3. 3. UltraSPARC T2 Processor SPC SPARCv9 CMT Core L2 Data L2 Data Bank 0 Bank 4 CCX Core-Cache Crossbar L2B0 SPARC SPARC SPARC SPARC L2B4 L2$ Level 2 Cache Bank L2 Data Core 0 Core 1 Core 5 Core 4 L2 Data CLC Coherence & Link Controller Bank 1 Bank 5 MCU Memory Control Unit L2B1 L2B5 SIU System Interface Unit L2 L2 L2 L2 MCU0 MCU2 NCU Non-cacheable Unit NCU TAG0 TAG1 TAG5 TAG4 FSR MAC Media Access Controller EFU MCU1 MCU3 DMU Data Management Unit SIO SII L2B3 CCX L2B7 FSR CCU PEU PCI Express Unit L2 Data L2 Data Bank 3 Bank 7 L2 L2 L2 L2 L2B2 L2B6 TAG2 TAG3 TAG7 TAG6 L2 Data L2 Data Bank 2 Bank 6 SPARC SPARC SPARC SPARC DMU Core 2 Core 3 Core 7 Core 6 RDP TDS PEU RTX PSR ESR FSR MACFor a video tour with Rick Hetherington, go to http://www.youtube.com/watch?v=B8DNexYcsa4 Sun Internal and Approved Partners Only 3
  4. 4. UltraSPARC T2 Plus: • Per Socket Multi-Socket US T2 > Up to 8 cores @1.2GHz orEach Coherency Link 6.4GBytes/s per direction, 12.8GB/s total 1.4GHz 4 x Coherency links give Snoop bandwidth of 51.2GB/s > Up to 64 Threads per socket 4x Coherency > 4MB L2$ 8 banks x 16 Way SA Links > Up to 8 FPUs, 1 per core FB-DIMM FB-DIMM FB-DIMM FB-DIMM > Up to 8 Crypto cores, 1 per core FB-DIMM FB-DIMM FB-DIMM FB-DIMM > DES, 3DES, AES, RC4, SHA1, SHA256, MD5, RSA to 2048 key, ECC,CRC32 MCU MCU > 2 memory Controllers, 16 DIMMS CU CU CU CU > 25Read+13WriteGB/s Memory BW L2$ L2$ L2$ L2$ L2$ L2$ L2$ L2$ > One x8 PCIe interface Full Cross Bar • Per system CO C1 C2 C3 C4 C5 C6 C7 > 2 sockets glue-less FPU FPU FPU FPU FPU FPU FPU FPU > 4 sockets using UST2 Plus XBR MAU MAU MAU MAU MAU MAU MAU MAU > 16 or 32 PCIe lanes on 2 or 4 System I/F PCI-Express Socket systems • 65nm process technology SSI x8 @2.5GHz Bus Power ~105W 4GBytes/s <1.5W/thread bi-directional Sun Internal and Approved Partners Only 4
  5. 5. UltraSPARC T2 Plus Processor SPC SPARCv9 CMT Core CCX Core-Cache Crossbar L2$ Level 2 Cache Bank CLC Coherence & Link Controller MCU Memory Control Unit SIU System Interface Unit NCU Non-cacheable Unit NCX Non-cacheable Crossbar DMU Data Management Unit PEU PCI Express Unit Sun Internal and Approved Partners Only 5
  6. 6. CMT Processor Comparison UltraSPARC T1 UltraSPARC T2 UltraSPARC T2 PlusTechnology 90nm 65nm 65nm# of Cores 8 8 8# of Threads 32 64 64# of Sockets 1 1 1–4Core Frequency (Ghz) 1 – 1.4 1.2 – 1.4 1.2 – 1.4Execution pipelines per core 1 2 2Instructions per cycle per pipe 1 1 1FPUs per chip 1 8 8I$ size (per core) 16KB 16KB 16KBD$ size (per core) 8KB 8KB 8KBL2$ size/Set Association 3MB/12-Way 4MB/16-Way 4MB/16-WayMemory Type DDR2 FBDIMM-1 FBDIMM-1Memory Bandwidth (GB/s) 21.3 42READ + 21WRITE 25READ + 13WRITECoherence Bandwdth (GB/s) - - 4 x (6.4READ +6.4WRITE)IO Bus JBUS x8 PCIe x8 PCIeIO Bandwidth (GB/s) 2.5 2+2 2+2On-chip Networking - 2 x 10GE -Crypto Acceleration RSA RSA, RC4, DES, 3DES, AES, SHA1-256, MD5Power (Watts, Watts/thread) 72, 2.25 95, 1.5 105, 1.6 * Sun Internal and Approved Partners Only 6
  7. 7. UltraSPARC T2 Plus 2-Socket System Coherency Links Dual Channel Dual Channel Dual Channel Dual Channel FBDIMM FBDIMM FBDIMM FBDIMM Memory Controller Memory Controller Memory Controller Memory Controller Coherence Coherence Coherence Coherence Coherence Coherence Coherence Coherence Unit Unit Unit Unit Unit Unit Unit Unit UltraSPARC T2 Plus Cores, Crossbar, L2$ UltraSPARC T2 Plus Cores, Crossbar, L2$ (8 cores, 64 threads, 4MB L2$) (8 cores, 64 threads, 4MB L2$) PCI-Express NCU, DMU NCX PCI-Express NCU, DMU NCX System IO (Network, Disk, etc.) Sun Internal and Approved Partners Only 7
  8. 8. UltraSPARC T2/Plus CPU Core Block Diagram • IFU – Instruction Fetch Unit > 16 KB I$, 32B lines, 8-way SA TLU IFU > 64-entry fully-associative ITLB • EXU0/1 – Integer Execution Units > 4 threads share each unit > Executes one integer instruction/cycle EXU0 EXU1 • LSU – Load/Store Unit > 8KB D$, 16B lines, 4-way SA MMU/ > 128-entry fully-associative DTLB HWTW • FGU – Floating/Graphics Unit • SPU – Stream Processing Unit > Cryptographic acceleration SPU FGU LSU • TLU – Trap Logic Unit > Updates machine state, handles exceptions and interrupts • MMU – Memory Management Unit > Hardware tablewalk (HWTW) Gasket – TLB miss handled by hardware > 8KB, 64KB, 4MB, 256MB pages xbar/L2 Sun Internal and Approved Partners Only 8
  9. 9. Floating Point Unit • Each Core has its own Floating Point Unit. This removes completely the 2% FP restriction of T1. • Only a 6 cycle penalty to the FPU > T1 required upwards of 28 cycles • Fully-pipelined (except divide/sqrt) Data > Divide/sqrt in parallel with add or multiply operations of other threads • Full VIS 2.0 implementation in hardware, no emulation • FPU performs integer multiply, divide, population count • Multiplier incorporates enhancements for offloading modular arithmetic operations to the Crypto Unit●● Sun Internal and Approved Partners Only 9
  10. 10. FB-DIMM Memory Interface Feature UltraSPARC T1 UltraSPARC T2 UltraSPARC T2 Plus Require Pins 1000 440 208 Available Bandwidth 23GBytes/second 50Gbytes/second 37.5Gbytes/second/socket Up to 64x DIMM slots Up to 32x DIMM slots/socket Memory Capacity up to 16x DIMM slots T5x20 uses 16 DIMM slots T5x40 uses 8/16 DIMM slots Data Memory Controllers 4 4 2 Memory Latency 96ns 126ns 126ns DIMM speeds 400MHz 667MHz 667MHz DIMM Power 7watts/DIMM 12.5Watts/DIMM 12.5Watts/DIMM●● Sun Internal and Approved Partners Only 10
  11. 11. 10/100/1000/10GbE Network Interfaces • Uses the Neptune Chip on the Motherboard which provides > Two RJ-45 ports dedicated for 10/100/1000 > Two RJ-45 ports capable of 10/100/1000 – Fitting a XAUI adapter disables the one of these ports per XAUI • Same 10 GbE XAUI cards as T5x20 server • 16 Rx and 24 Tx DMA channels for virtualization – Integrated NIU in T2 has 16 Tx channels Data – Raw UDP Tx performance on Neptune > T2 NIU – T2 processor network typically outperforms Neptune on most network benchmarks • Packet classification > Rx data can be HW classified at layer 2 ,3 and 4 – Put into the separate Rx DMA buffers by classification rules • Same nxge device driver as T2 NIU. • Performance estimates, testing/tuning ongoing – 1 port 10GbE TX/RX = 9.3 Gbps with CPUs still 65-75% idle● – 2 port 10GbE TX/RX = 12-19Gbps (better if dedicate RX/TX ports)● Sun Internal and Approved Partners Only 11
  12. 12. T5140/T5240 Extreme Rackmount Density Dual UltraSPARC T2 Plus • 1 / 2RU chassis, 28” depth • Two sockets > Up to 8 cores @ 1.2GHz at RR – 1.4GHz to follow > Up to 128 threads • 161U/2U/ 322U FB-DIMM memory slots > 64/128GB of memory, 4GB DIMMs High Reliability• Up to 128 threads / 128GB memory / 128 • Up to 4 (1U) or 8/16 (2U) Hot-Plug LDoms in a 1U / 2U redundant chassis SATA/SAS 2.5” HDD (Raid 0,1) > RAID 5 BBWC card post-RR• Over 5,100 threads per rack ! • Redundant, hot-swappable PSUs and• High RAS and I/O bandwidth Fans. DC Option for 2U • Certain Configs are Hi-Line Power only• Scale-Up / Scale-Out of application infrastructure Expandable • 3/6 PCI-E expansion slots > including 2 x 10 GBE I/0 XAUI slots • 4 x 1GbE Ethernet as standard • 4 USB ports Sun Internal and Approved Partners Only 12
  13. 13. T5x40 Standard Configurations (PTO) Part Number Description 1RU 2 x 4 Core, 64 Threads, 1.2Ghz, 8GB (8 X 1GB), SETPAAE1Z 4 disk capable, 2x 146GB disks, 2x 720W PSU, DVD 2 x 6 Core, 96 Threads, 1.2Ghz, 16GB (8 X 2GB), SETPBGE1Z 4 disk capable, 2x 146GB disks, 2x 720W PSU, DVD 2 x 8 Core, 128 Threads, 1.2Ghz, 32GB (16 X 2GB), SETPCJE1Z 4 disk capable, 2x 146GB disks, 2x 720W PSU, DVD 2 x 8 Core, 128 Threads, 1.2Ghz, 64GB (16 X 4GB), SETPCPE1Z 4 disk capable, 2x 146GB disks, 2x 720W PSU, DVD Part Number Description 2RU 2 x 6 Core, 96 Threads, 1.2Ghz, 8GB (8 X 1GB), SEUPBAE1Z 8 disk capable, 2x 146GB disks, 2x 1100W PSU, DVD 2 x 8 Core, 128 Threads, 1.2Ghz, 32GB (16 X 2GB), SEUPCJE1Z 8 disk capable, 2x 146GB disks, 2x 1100W PSU, DVD 2 x 8 Core, 128 Threads, 1.2Ghz, 64GB (16 X 4GB), SEUPCPE1Z 8 disk capable, 2x 146GB disks, 2x 1100W PSU, DVD 2 x 8 Core, 128 Threads, 1.2Ghz, 64GB (16 X 4GB), SEUPCPE2Z 16 disk capable, 2x 146GB disks, 2x 1100W PSU, DVD HIGHLINE POWER ONLY (220VAC) 2 x 8 Core, 128 Threads, 1.4Ghz, 64GB (16 X 4GB), SEUPDPE1Z 16 disk capable, 2x 146GB disks, 2x 1100W PSU, DVD HIGHLINE POWER ONLY (220VAC) Sun Internal and Approved Partners Only 13
  14. 14. Sun Fire T1000/T5120/T5140 Differences Feature Sun Fire T1000 SPARC Enterprise T5120 SPARC Enterprise T5140 Form Factor 1U, 18¾” deep 1U, 28” deep 1U, 28” deep UltraSPARC T1 UltraSPARC T2 2x UltraSPARC T2 Plus CPU 1.0 GHz, 16-32 threads 1.2/1.4 GHz 32-64 threads 1.2/1.4 GHz 64-128 threads DDR2 32GB Max FB-DIMM 64GB MAX FB-DIMM 64GB MAX Memory 8x slots 16x slots 16x slots 4 x 1GbE or Network 4 x GbE 4 x GbE + 2 x 10GbE 3 x 1Gbe + 1 x 10GbE or 2 x 1GbE + 2 x 10GbE 1x 3.5” SATA, non-hot-swap Internal Storage Up to 8 x 2.5” SAS, hot-swap Up to 4 x 2.5” SAS, hot-swap OR 2x 2.5” SAS Removable Media None 1x DVD-RW 1x DVD-RW Serial 1x RS-232, No USB 1x RS-232, 4x USB 1x RS-232, 4x USB PCI Express slots 1x (low profile) 3x(low profile) 3x(low profile) 1x 300W AC 2x 650W AC & DC option 2x 720W AC Power Supply Non-Redundant Redundant/Hot-Swap Redundant/Hot-Swap Fans Non-Hot-Swap 4 x Redundant/Hot-Swap 6 x Redundant/Hot-Swap Sun Internal and Approved Partners Only 14
  15. 15. Sun Fire T2000/T5220/T5240 Differences Feature Sun Fire T2000 SPARC Enterprise T5220 SPARC Enterprise T5240 Form Factor 2U, 24” deep 2U, 28” deep 2U, 28” deep UltraSPARC T1 UltraSPARC T2 2x UltraSPARC T2 Plus CPU 1.0 - 1.4GHz 32 threads 1.2/1.4 GHz 64 threads 1.2/1.4 GHz 64-128 threads DDR2, 64GB MAX FB-DIMM, 64GB MAX FB-DIMM 128GB MAX Memory 16x Slots 16x Slots 32x slots 4 x GbE or Network 4x GbE 3 x GbE + 1 x 10GbE or 4x GbE + 2x 10GbE 2 x GbE + 2 x 10GbE Internal Storage 4x 2.5” SAS, hot-swap 8 x 2.5” SAS, hot-swap Up to 16 x 2.5” SAS, hot-swap Removable Media 1x DVD-ROM 1x DVD-RW 1x DVD-RW Serial 1x RS-232, 4x USB 1x RS-232, 4x USB 1x RS-232, 4x USB PCI Express slots 3x (low profile) 6x (low profile) 6x (low profile) PCI-X slots 2x (low profile) None None 2x 450W AC 2x 750W AC 2x 1100W AC/2 x1200Watt DC Power Supply Redundant/Hot-Swap Redundant/Hot-Swap Redundant/Hot-Swap Fans 3 x Redundant Hot-Swap 3 x Redundant Hot-Swap 5x Redundant/Hot-Swap Sun Internal and Approved Partners Only 15
  16. 16. Front Panel Dual USB 2.0 ports Locator LED /Button DVD-RW Disk Drive Map Fault LED Top Fault LED Status LED Power Button DISK 0 DISK 1 DISK 2 DISK 3 PSU Fault LED Temp Fault LEDSerial Number label Locator LED /Button Fault LED Status LED Top Fault LED Power Button PSU Fault LED Temp Fault LED DISK 1 DISK 3 DISK 5 DVD-ROM Disk Drive MapSerial Number DISK 0 DISK 2 DISK 4 DISK 6 DISK 7 Dual USB 2.0 ports DISK 3 DISK 7 DISK 12 DISK 15 DISK 2 DISK 6 DISK 11 DISK 14 DISK 1 DISK 5 DISK 9 DVD-RW DISK 0 DISK 4 DISK 8 DISK 10 DISK 13 Sun Internal and Approved Partners Only 16
  17. 17. Rear Panel PCI/XAUI 0 PCI/XAUI 1 PCI 2PSU PSU 0 PSU 1StatusLEDs Chassis Status LEDs Quad Gigabit Dual POSIX DB-9 and Locator Button Ethernet Ports USB 2.0 Serial Port SP SP Ports Serial Network Port Port PSU 1 PCI 3 PCI 4 PCI 5 PCI/XAUI 0 PCI/XAUI 1 PCI 2 PSU 0 Chassis PSU Status LEDs Quad Gigabit POSIX DB-9 Status Dual and Locator Button Ethernet Ports USB 2.0 Serial Port LEDs SP SP Ports Serial Network Port Port Sun Internal and Approved Partners Only 17
  18. 18. T5140 Block Diagram CL 1RU=16 DIMMS x8 SSI x8 SSI x4 x4 PCIe x8 x8 PCIe LSI x1 Switch SwitchDisk Chassis 1068E PLX 8548 PLX 8548 FPGA1RU=4 Disks x8 x8 PCIe x8 to x4 NEPTUNE PCI Ethernet 33MHz XAUI XAUI 2 x 10/100/1000 2 x 10/100/1000/10000 32bit USB 2.0 to IDE PCI to MPC885 DVD USB ILOM USB 2.0 2.0 QUAD GbE Service Hub PHY BCM5466R Processor USB 2.0Front Panel 0 1 2 3 USB PCIe PCIe PCIe Quad GbE Serial Network POSIX Rear Panel x16 x8 x8 Connectors Mgt Mgt Serial DB-9 Slot2 Slot1 Internal and Approved Partners Only Sun Slot0 18
  19. 19. T5240 Block Diagram 2RU Memory Mezzanine Tray 2RU=16 DIMMS without Mezannine, 32 DIMMS with mezannine Option CL x8 SSI x8 SSI x4 x4 PCIe x8 x8 PCIe LSI x1 Switch SwitchDisk Chassis x4 1068E PLX 8548 PLX 8548 FPGA2RU = 8 or 16 Disks x8 x8 x8 PCIe x8 x8 x8 to x4 NEPTUNE PCI Ethernet 33MHz XAUI XAUI 2 x 10/100/1000 2 x 10/100/1000/10000 32bit USB 2.0 to IDE PCI to MPC885 DVD USB ILOM 2RU 2RU 2RU USB 2.0 2.0 QUAD GbE Service Hub PHY BCM5466R Processor USB 2.0Front Panel 0 1 2 3 USB PCIe PCIe PCIe PCIe PCIe PCI- Quad GbE Serial Network POSIX Rear Panel x16 x8 x8 x8 x8 ex8 Connectors Mgt Mgt Serial DB-9 Slot2 Slot5 Slot1 Internal and Approved Partners Only Sun Slot4 Slot0 Slot3 19
  20. 20. Internal View (T5140) Fault Remind System Configuration Service Processor Button Card (SCC)EEPROM FB0/FM0 FB1/FM0 FB0/FM0 UltraSPARC UltraSPARC UltraSPARC UltraSPARC PCIe Slot 2 T2 Plus 0 T2 Plus 0 x16(m)/x8(e) FB-DIMMs FB0/FM1 FB1/FM1 FB0/FM1 PCIe Slot 1 x8(m)/x8(e) or XAUI 1 T2 Plus 1 T2 Plus 1 Disk Chassis FB-DIMMs FB1/FM2 FB0/FM2 PCIe Slot 0 x8(m)/x8(e) or XAUI 0 Neptune PSU1 Network ASIC Power Power Board Supplies PSU0SAS x4 cable to Power BUS Bars Memory Mezannine Connectors Disk Chassis 6 Fan Assemblies are required X4 SAS Connector 0 (cable attached) RED = +12Volts (not used on T5140) X4 SAS Connector 1 (not used in 1RU) (chassis can take up to 8) BLUE = Ground Chassis Intrusion Reed Switch (magnet on underside of lid) Sun Internal and Approved Partners Only 20
  21. 21. Internal View (T5240 without Mezzanine) Fault Remind System Configuration Service Processor Button Card (SCC)EEPROM FB0/FM0 FB1/FM0 FB0/FM0 PCIe Slot 2 UltraSPARC UltraSPARC UltraSPARC UltraSPARC x8(m)/x8(e) T2 Plus 0 T2 Plus 0 x16(m)/x8(e) FB-DIMMs PCIe Slot 1 x8(m)/x8(e) x8(m)/x8(e) FB0/FM1 FB1/FM1 FB0/FM1 FB1/FM1 or T2 Plus 1 T2 Plus 1 XAUI 1 Disk Chassis FB-DIMMs PCIe Slot 0 x8(m)/x8(e) x8(m)/x8(e) or XAUI 0 FB0/FM2 FB0/FM2 Power Power PSUs Board Supplies Vertically Stacked Power BUS Bars Memory Mezannine Connectors X4 SAS Connector 0 (cable attached) 5 Fan Assemblies are required RED = +12Volts X4 SAS Connector 1 (not used in 1RU) (chassis can take up to 6) BLUE = Ground Chassis Intrusion Reed Switch (magnet on underside of lid) Sun Internal and Approved Partners Only 21
  22. 22. Internal View (T5240 with Mezzanine) Mezzanine Air Fault Remind System Configuration Service Processor Guide Button Card (SCC)EEPROM FB0/FM0 FB1/FM0 FB1/FM0 PCIe Slot 2 x8(m)/x8(e) x16(m)/x8(e) FB-DIMMs PCIe Slot 1 x8(m)/x8(e) x8(m)/x8(e) FB0/FM1 FB1/FM1 FB0/FM1 FB1/FM1 or XAUI 1 Disk Chassis FB-DIMMs PCIe Slot 0 x8(m)/x8(e) x8(m)/x8(e) or XAUI 0 FB0/FM2 FB0/FM2 Power Power PSUs Board Supplies Vertically Stacked Power BUS Bars Memory Mezannine Handles 5 Fan Assemblies are required RED = +12Volts (chassis can take up to 6) BLUE = Ground Chassis Intrusion Reed Switch (magnet on underside of lid) Sun Internal and Approved Partners Only 22
  23. 23. Motherboard Memory Physical LayoutChassis ChassisFront Rear Channel0/DIMM 1/Branch 1 CMP0/Branch1/Channel1/DIMM0 1 Channel0/DIMM 1/Branch 1 CMP0/Branch1/Channel1/DIMM1 3 2 Channel0/DIMM 1/Branch 1 CMP0/Branch1/Channel0/DIMM1 2 Channel0/DIMM 1/Branch 1 CMP0/Branch1/Channel0/DIMM0 1 SECOND Install ALL DIMMs in UltraSPARC Channel0/DIMM 1/Branch 1 CMP0/Branch0/Channel0/DIMM0 1 Group 2 T2 Plus 0 Channel0/DIMM 1/Branch 1 CMP0/Branch0/Channel0/DIMM1 2 12 DIMM Config Channel0/DIMM 1/Branch 1 CMP0/Branch0/Channel1/DIMM1 2 Channel0/DIMM 1/Branch 1 CMP0/Branch0/Channel1/DIMM0 1 FIRST Install ALL DIMMs in Group 1 8 DIMM Minimum UltraSPARC Channel0/DIMM 1/Branch 1 CMP1/Branch1/Channel1/DIMM0 1 Config T2 Plus 1 Channel0/DIMM 1/Branch 1 CMP1/Branch1/Channel1/DIMM1 3 Channel0/DIMM 1/Branch 1 CMP1/Branch1/Channel0/DIMM1 3 Channel0/DIMM 1/Branch 1 1 THIRD CMP1/Branch1/Channel0/DIMM0 Install ALL DIMMs in Channel0/DIMM 1/Branch 1 CMP1/Branch0/Channel0/DIMM0 1 Group 3 Channel0/DIMM 1/Branch 1 CMP1/Branch0/Channel0/DIMM1 3 16 DIMM Config Channel0/DIMM 1/Branch 1 CMP1/Branch0/Channel1/DIMM1 3 Channel0/DIMM 1/Branch 1 CMP1/Branch0/Channel1/DIMM0 1 At RR, Supported configs will be ... All DIMMs MUST be the same Size i.e 1GB, 2GB, 4GB, no mixing Fully Populate Group 1 and 2 (8 DIMMS) All DIMMs in a Branch must be the same Sun Part Number Fully Populate Groups 1, 2 and 3 (16 DIMMS) Unused DIMM locations must be occupied with DIMM Fillers Sun Internal and Approved Partners Only 23
  24. 24. Mezzanine Memory Physical LayoutChassis ChassisFront Rear Channel0/DIMM 1/Branch 1 CMP0/MR0/BR1/CH1/DIMM3 4 Channel0/DIMM 1/Branch 1 CMP0/MR0/BR1/CH1/DIMM2 3 4 CMP0/MR0/BR1/CH0/DIMM2 4 CMP0/MR0/BR1/CH0/DIMM3 4 FOURTH Install ALL DIMMs in CMP0/MR0/BR0/CH0/DIMM3 4 Group 4 CMP0/MR0/BR0/CH0/DIMM2 4 24 DIMM Config CMP0/MR0/BR0/CH1/DIMM2 4 CMP0/MR0/BR1/CH1/DIMM3 4 CMP1/MR1/BR1/CH1/DIMM3 5 CMP1/MR1/BR1/CH1/DIMM2 5 CMP1/MR1/BR1/CH0/DIMM2 5 5 FIFTH CMP1/MR1/BR1/CH0/DIMM3 Install ALL DIMMs in CMP1/MR1/BR0/CH0/DIMM3 5 Group 5 CMP1/MR1/BR0/CH0/DIMM2 5 32 DIMM Config CMP1/MR1/BR0/CH1/DIMM2 5 Channel0/DIMM 1/Branch 1 CMP1/MR1/BR0/CH1/DIMM3 5 At RR, Supported configs will be ... All DIMMs MUST be the same Size i.e 1GB, 2GB, 4GB, no mixing Fully Populate Groups 1, 2, 3 , 4 and 5 (32 DIMMS) All DIMMs in a Branch must be the same Sun Part Number Unused DIMM locations must be occupied with DIMM Fillers Sun Internal and Approved Partners Only 24
  25. 25. Memory Configuration Rules• Populate at least 4 DIMMS at a time• Populate by complete group only (set 1, 2, 3, 4, 5) > Groups may be 4 or 8 DIMMs, check service labels on lid• Ensure proper installation of Airflow Guides > All Configs require DIMM fillers for correct air-flow > 1RU has no Airflow Guide > 2RU has two configurations – No Mezzanine – Install Lower Air Guide – With Mezzanine – Install Lower PDB Guide and Mezzanine Guide• All DIMMS must be the same size(i.e all 1GB, 2GB or 4GB, no mixing)• In a Group all DIMMS must have the same SUN Part No.• No clocking down of memory in any config.• 8GB DIMMs will be qualified/evaluated after RR Sun Internal and Approved Partners Only 25
  26. 26. Network Ports and Options XAUI 0 XAUI 1 Device NET 0 NET 1 NET 2 NET 3 XAUI 0 XAUI 1 Driver nxge0 nxge1 nxge2 nxge3 nxge0* nxge1* PCI Device PCI@300/0/8/0,0 PCI@300/0/8/0,1 PCI@300/0/8/0,2 PCI@300/0/8/0,3 PCI@300/0/8/0,0 PCI@300/0/8/0,1 NOTES All Ethernet ports provided by a single Neptune Chip on the motherboard NET 0 and NET 1 are disabled by XAUI cards if installed to take advantage of 10GbE networking * If a XAUI card is installed, the matching RJ-45 port is disabled XAUI cards take one of three current Fibre 10GbE transceivers Short Reach(SR), Long Reach(LR) and Long Reach Multimode(LRM) Copper versions of the XAUI card are expected Post-RR XAUI Cards consume the same physical space in the chassis as a PCI card, so are mutually exclusive with PCI cards in the same location Sun Internal and Approved Partners Only 26
  27. 27. 10GbE XAUI Option Cards• Interface to the Neptune chip to upgrade two of its ports to 10GbE• Cards each consume a PCIe slot if installed• Attach to dedicated XAUI sockets on special risers• 10Gbe XAUI Card – SESY7XA1Z > Requires Fibre Tranceivers – 10GbE Short Reach(SR) – SESY7XT1Z – 10GbE Long Reach (LR) – SESY7XT2Z – 10GbE Long Reach multimode (LRM) – part No. TBD• Copper connector XAUI versions to follow post-RR Sun Internal and Approved Partners Only 27
  28. 28. PCI Riser Cards• Various Riser Cards are used• Risers should not be moved between slots• All slots accommodate low Profile PCI-Express cards• T5140 – 25 Watts per card, 75 Watts Max (3 Slots)• T5240 – 25 Watts per card, 102 Watts Max (6 Slots) > Riser Card Mechanical and Electrical widths for T5140 and T5240 T5140 Slot 0 Slot 1 Slot 2 Only Slot x8/XAUI(m) x8(e) x8/XAUI(m) x8(e) x16(m) x8(e) T5240 Slot 1 Slot 1 Slot 2 Top Slot x8(m) x8(e) x8(m) x8(e) x8(m) x8(e) Bottom Slot x8/XAUI(m) x8(e) x8/XAUI(m) x8(e) x16(m) x8(e) Sun Internal and Approved Partners Only 28
  29. 29. Disk Cage• Disk chassis is a FRU – 4 screws and disconnect cables• Contains DVD-RW/Dual USB module as a sub-FRU/CRU – Standard in all default configs – remove disk 3/7 to access release latch, pre-RR• Non-DVD module available as X-Option – Still provides Dual USB ports Remove Disk and locate latch beneath DVD Press up and pull DVD out• T5140 will be available with only a 4 disk chassis (8 disk may be post RR) > Only uses one of the x4 SAS links• T5240 will be available with 8 or 16 disk chassis > 16 Disk systems requires High-Line Power (220VAC) Sun Internal and Approved Partners Only 29
  30. 30. Disk Drives• Disk drives are all 2.5” form factor• Chassis support both SAS and SATA (post-RR)• SAS Drives – 73GB @ 10K RPM – 146GB @ 10K RPM – 73GB @ 15K RPM Improved Airflow above and below – 146GB @ 15K RPM (post-RR) disks• SATA Drives – 300GB @ 5400 RPM (H2CY08) – 500GB @ 7200 RPM (end CY08) Disk LEDs• New mounting bracket “Marlin” Ready to Remove > Allows better cooling in denser chassis Fault Status• Same disks as T5x20 systems Sun Internal and Approved Partners Only 30
  31. 31. Disk Controller Options• T5x40 has embedded LSI1068E on the motherboard – JBOD up to 8 disks – Controls internal disks only – RAID 0 (striping) and RAID 1(mirroring), using radictl – Hot-plug supported – Hot-swap in non-RAID configs is done with cfgadm• Optional Extended RAID functionality cards > SPARC Drivers are available, SAS cables are being produced now > SGXPCIESAS-R-INT-Z – 8 port SAS RAID 0,1,1E,5,5EE,6,10,50,60 (depending on number of disks available) – Adaptec Card and Firmware with Intel SunRiseLake chipset – Battery Backed Write Cache (BBWC) of 256MB – BBWC battery at least 72 hours (much longer when new/fully charged) – Only for internal disks, replaces cables to route to standard disk chassis > SGXPCIESAS-R-EXT-Z – External port version, for external disk arrays only (no internal ports) > Not available for T5440 due to chassis design and only 4 disk capacity Sun Internal and Approved Partners Only 31
  32. 32. Fans and Cooling• T5140 Unused Fan slots can be populated, but not recommended, fans will run and wear, so not a great way of keeping spares.... > Requires 6 Fan modules – Main System Cooling FBD1 FBD0 PSUs FM3 FM3 FM3 – FANBD0/FM0 Disk Chassis Disk Chassis FBD1 – FANBD0/FM1 FBD0 FM2 FM2 FM2 – FANBD0/FM2 – FANBD1/FM0 FBD1 FBD0 Motherboard FM1 FM1 FM1 – FANBD1/FM1 – FANBD1/FM2 FBD1 FBD0 FM0 FM0 FM0 – No Modules in FM3• T5240 Back Front > Requires 5 Fan Modules – Main system Cooling PSUs FBD1 FBD0 FM2 FM2 FM2 FM2 – FANBD0/FM0 Disk Chassis Disk Chassis – FANBD0/FM1 FBD1 FBD0 FM1 FM1 FM1 FM1 – FANBD0/FM2 Motherboard – FANBD1/FM0 – FANBD1/FM1 FBD1 FBD0 FM0 FM0 FM0 – No Modules in FANBD1/FM2 Sun Internal and Approved Partners Only 32
  33. 33. Fans modules and boards• Fans are speed controlled by the Service Processor• Each fan has an Amber FAULT LED – if lit the fan module is faulty• 1RU modules – 2 Fans at 15K RPM Max. Fan Fault• 2RU modules Amber LED – 2 Fans at 12K RPM Max Lit if fan faulty• Monitored through ILOM/IPMI/Web Vibration Absorbing Silicon Dampers Sun Internal and Approved Partners Only 33
  34. 34. Power Supplies• PSUs are high efficiency• Output 12V (and 3.3v standby) PSU LEDs• Most DC-DC conversion done in MBD Ready to Remove Fault• Shared with Doradi/o, Tucani/a AC Present• Integrated Fan• T5140 > Side-by-Side > AC 720Watts• T5240 > Vertically Stacked > 1100Watts > DC 1200 Watts option coming post-RR > DC or AC, no sharing > BEWARE... – Same form factor as SunFire X4200 PSUs ... DO NOT MIX – 1.4Ghz and 16 Disk configs require 220VAC (called “High Line Power”) Sun Internal and Approved Partners Only 34
  35. 35. Rack Mounting Options• Two Rack mounting options are available..• Standard Rack Mount (4 post)SESY9RK1Z > Standard configs contain this kit – ATO : SESY9RK1Z, X-ATO : SESY9RK1Z• Tool-less Rack Kit (4 post) > Optional kit, purchased seperately > Snaps into most 3rd party Racks > Requires no tools to fit or remove – ATO : SESY9RK2Z, X-ATO : SESX9RK2Z Sun Internal and Approved Partners Only 35
  36. 36. Solaris for Sun SPARC Enterprise T5x40• T5x40 servers will require Solaris10 8/07 (update 4) with patches > A Patch CD is supplied in the box – Mandatory patches = 127111-08,126434-05,125416-05 – Available patches = 124235-02, 125369-13,125476-02,127111-07 – Likely to be out of date, so customers should check SunSolve...• This incorporates several specific UltraSPARC T2/T2 Plus optimizations and for CMT servers in general• Also includes some specific T5x40 optimisations > UltraSPARC T2 Plus MPO optimisations > nxge driver tweaks for 10GbE devices > MMU DMA relaxed scheduling > LDOMs pre-install upgrade to version 1.0.2 (US T2 Plus support) Sun Internal and Approved Partners Only 36
  37. 37. Solaris FMA• Now aware of CPU Core offlining• PCIe Fabric diagnostics improved• Crypto Unit offlining• Neptune awareness (though XAUIs not diagnosed)• POST memory CE tolerance improved• FRU identity info improved in fault reports (part/ser #)• Diagnostic Engines (DE) – Existing DE have been extended for T5x40 – New Eversholt DE used for HostBridge, PCIe diagnostics• Limitations... – Cant isolate Uncorrectable Errors to a single DIMM – PCIe riser cards not in topology – XAUI card and XFP not in the topology – SouthBridge chip is not diagnosed at this time (DVD, USB,...) – IO Expansion box is not diagnosed via FMA Sun Internal and Approved Partners Only 37
  38. 38. ILOM Features at a Glance• Hardware Control, Inventory, Monitoring• Host Configuration and Administration• SP Configuration and Administration• Logging, Auditing and Alerting• Authentication : – LDAP, RADIUS, Active Directory, Local Users• Services : – SSH, HTTP(S), NTP, Syslog, SMTP• Out-of-Band – Via Serial port, or dedicated Ethernet port• In-Band – Via Host OS, firmware upload, Explorer, Syslog Sun Internal and Approved Partners Only 38
  39. 39. ILOM – Industry Standard Manageability • ILOM enables Sun systems to be easily integrated into third party management infrastructures • Key functionality > IPMI 2.0 > SNMP V1, V2c, V3 > SSH 2.0 > LDAP, RADIUS & MS Active Directory authentication > Browser UI, SMASH DMTF CLP + ALOM style CLI • NOTE : No RKVMS functionality like Galaxy ILOM > No Java plugin required • Browsers tested include, these base versions an later releases – Mozilla 1.7 on Solaris 10, IE 6.0 on W2K Server, Firefox 1.0 and 1.5 on W2K server Sun Internal and Approved Partners Only 39
  40. 40. ILOM – Industry Standard Manageability • Identical to ILOM 2.0 for T5x20 • Default user is root with password changeme > Use for ILOM WEB GUI access and SSH access and IPMI • The ALOM admin user is not defined by default, create this user with an ALOM CLI • Lost root password and ILOM config is reset using jumpers > T5140/T5240 - Motherboard Jumper J10401 (short pins 1-2) • Note... sunservice user shares the password of the root user ONLY FOR SERVICE ACCESS* • Passwords must be 8 to 16 chars (used to be max 8) • Max of 10 users allowed (used to be 16) Sun Internal and Approved Partners Only 40
  41. 41. ILOM Common Tasks• Setting up an ALOM admin user from the ILOM CLI > SUNSP00144F4641BD login: root Password: changeme Waiting for daemons to initialize... Daemons ready Sun(TM) Integrated Lights Out Manager Version 2.0.4.0 Copyright 2007 Sun Microsystems, Inc. All rights reserved. Use is subject to license terms. Warning: password is set to factory default. ->create /SP/users/admin role=Administrator cli_mode=alom Creating user... Enter new password: ******** Enter new password again: ******** Created /SP/users/admin2 -> exit SUNSP00144F4641BD login: admin Password: ******** Waiting for daemons to initialize... Daemons ready Sun(TM) Integrated Lights Out Manager Version 2.0.4.0 Copyright 2007 Sun Microsystems, Inc. All rights reserved. Use is subject to license terms. sc> Sun Internal and Approved Partners Only 41
  42. 42. ILOM Common Tasks• Setting up ILOM IP configuration from the ILOM CLI > SUNSP00144F4641BD login: root Password: changeme Waiting for daemons to initialize... Daemons ready Sun(TM) Integrated Lights Out Manager Version 2.0.4.0 Copyright 2007 Sun Microsystems, Inc. All rights reserved. Use is subject to license terms. Warning: password is set to factory default. -> set /SP/network state=enabled Set ’state’ to ’enabled’ -> set /SP/network pendingipaddress=10.8.31.163 Set ’pendingipaddress’ to ’10.8.31.163’ -> set /SP/network pendingipdiscovery=static Set ’pendingipdiscovery’ to ’static’ -> set /SP/network pendingipnetmask=255.255.252.0 Set ’pendingipnetmask’ to ’255.255.252.0’ -> set /SP/network pendingipgateway=10.8.31.248 Static IP Set ’pendingipgateway’ to ’10.8.31.248’ configuration -> set /SP/network commitpending=true Set ’commitpending’ to ’true’ -> -> set/SP/pendingipdiscovery=dhcp Set ’pendingipdiscovery’ to ’dhcp’ -> set /SP/network commitpending=true Set ’commitpending’ to ’true’ -> Dynamic IP (DHCP) configuration Sun Internal and Approved Partners Only 42
  43. 43. ILOM IPMI functionality• IPMI is a widely used management protocol for x86 servers• ... But its new for SPARC boxes...• Download the required tools from > The Solaris Supplemental CD (an older binary package) > Latest is available at http://ipmitool.sourceforge.net – Binary packages (usually older versions) are available for Solaris x86 and SPARC, as well as Linux, Windows, Mac...etc > There is a Blueprint available from Sun also (mainly x64 centric, but applies to SPARC now too) – http://www.sun.com/blueprints/0107/820-1011.pdf -bash-ventus2$ /opt/ipmitool/bin/ipmitool -U root -P changeme -H 10.10.10.10 sdr /MB/V_+1V0_VDD | 1.01 Volts | ok /MB/V_+3V3_STBY | 3.36 Volts | ok Get the Sensor /MB/V_+3V3_MAIN | 3.36 Volts | ok Data /MB/V_+5V0_VCC | 4.97 Volts | ok Repository /MB/V_+12V0_MAIN | 12.16 Volts | ok .. .. -bash-ventus2$ /opt/ipmitool/bin/ipmitool -U root -P changeme -H 10.10.10.10 sunoem sbled set /SYS/LOCATE on /SYS/LOCATE | ON Set the System -bash-ventus2$ Locator LED flashing Sun Internal and Approved Partners Only 43
  44. 44. ILOM Common Tasks• Logging into the ILOM Web GUI • Point Web Browser at the IP address of the ILOM > Will automatically redirect to a secure HTTPS port > Best to disable any Web Proxies for best performance > Make sure port 80, 443 are open on any firewall • Log in as any defined user, default Administration user is root Sun Internal and Approved Partners Only 44
  45. 45. ILOM/ALOM Common Tasks• A Tour of the ILOM Web GUI • GUI provides ways to set up IP address configurations for ILOM • Configure additional ILOM/ALOM users • Access Sensor Readings • Control System configurations • Carry out firmware updates. • etc.... Sun Internal and Approved Partners Only 45
  46. 46. ALOM 2.0 vs. 1.4 CLI Differences• Default CLI appearance is ILOM – User is root – Must create an admin Administrator user with the ALOM CLI• Flashupdate in new ALOM expects a TFTP server not an FTP server• ALOM IP address changes now active only after running ... – setsc netsc_commit true – Previously changes were active only after SC reset – DHCP is enabled by default• View firmware versions with – showhost version sc> showhost version Sun System Firmware 7.0.0_build_13 2007/08/10 23:44• Only Admin and Operator roles Host flash versions: Hypervisor 1.5.0.build_13**PROTOTYPE** 2007/08/10 22:54 OBP 4.27.0.build_04***PROTOTYPE BUILD*** 2007/08/10 13:25 are defined Sun Fire[TM] Huron POST 4.27.0.build_04***PROTOTYPE BUILD*** 2007/08/10 13:51 Sun Internal and Approved Partners Only 46
  47. 47. ALOM backward Compatibilty CLI• Uses ALOM-CMT 1.2 for a base feature set• Includes ALOM-CMT 1.4 features... > break -d > Host Watchdog Timer > Bootmode LDOMs awareness > Forward SP events to Hot/Solaris syslog via inband channel Sun Internal and Approved Partners Only 47
  48. 48. Logical Domains 1.0.2 FeaturesRelease in Q1CY08 aligned with UltraSPARC T2 Plus launch• UltraSPARC T2 Plus Platform Support > 128 domains supported at RR – 256 domains work on T5440, may be qualified later, requires Solaris fixes• Feature Set very similar to 1.0.1• I/O domain can reboot while the other domains keep running > Dependant domains would wait for IO transactions to complete• LDoms SNMP MIB > Modeled after industry standard DMTF CIM (Common Information Model) > Running on control domain to enable remote SNMP monitoring• Domain minimization support > Minimal/reduced Solaris installation > Base minimal packages plus optional ones for guest, control, I/O or service domains Sun Internal and Approved Partners Only 48
  49. 49. Logical Domains 1.0.2 Requirements • Solaris 10 08/07 (update 4) and required patches • Systems firmware version – T5x40 Firmware 7.1.0 = SP FW 2.0.4.20+ – T5x20/SB6320 Firmware 7.0.4+ = SP FW 2.0.4.0+ – T2000/T1000/T6300/Pelton Firmware 6.5.x • SUNWldm.v LDOMs Manager Package – Version 1.0.2 Sun Internal and Approved Partners Only 49
  50. 50. CRU/FRU List - T5140• Lots shared with other Jake and Elwood systems Item Description FRU/CRU Disk Backplane 4 drive Disk Backplane to support 4 Drives only FRU Disk Backplane 8 drive Disk Backplane to support 8 Drives (post -RR) FRU Fan Module 1U Dual Fan module, 4 populated in system CRU Fan Board 1U Fan connector board to accommodate Fan Modules, 2 per system FRU DVD Assembly DVD Assembly including front USB board FRU Paddle board 1U Conection between PDB, fan boards and Disk Backplane FRU PDB 1U Power distribution board, contains master chassis serial number FRU PSU 1U Power supply (720 Watts) CRU X8 &XAUI, 1U PCIe Riser PCI Riser assembly for left and centre motherboard slots CRU x16 1U PCIe Riser PCI Riser for right motherboard slot CRU Rack mount kit (requires tools) Rack mount kit CRU Rack Mount Kit (tooless) Rack mount kit, no tools required for installation CRU CMA Cable management arm CRU Bus Bars Power Bus Bars between PDB and Motherboard FRU PDB to MB Ribbon Cable Ribbon cable for control connections between PDB abd Motherboard FRU Light pipe kit Light pipe assemblies for left and right of disk cage FRU Motherboard assembly Motherboard assembly, part no varies depending on Core count FRU DIMMs FBDIMMs (three different part numbers for 1GB, 2GB, 4GB) CRU XAUI board optical/copper XAUI Adapter card (two different parts for copper/optical) CRU XFP module XFP GBIC module for use in XAUI cards (three different parts SR, HR, HRMM) CRU Battery Battery backup for NVRAM of Service Processor CRU HDD 73GB/146GB SAS Hard Disk drive, different part numbers for capacities CRU System Configurations PROM System Configuration PROM FRU Maramba Cable Kit SAS Cable kit FRU Sun Internal and Approved Partners Only 50
  51. 51. CRU/FRU List - T5240• Lots shared with other Jake and Elwood systems Item Description FRU/CRU Disk Backplane 16 drive Disk Backplane to support 16 Drives only FRU Disk Backplane 8 drive Disk Backplane to support 8 Drives only FRU Fan Module 2U Dual Fan module, 3 populated in system CRU Fan Board 2U Fan connector board to accommodate Fan Modules, 2 per system FRU DVD Assembly DVD Assembly including front USB board FRU Paddle board 2U Connection between PDB, fan boards and Disk Backplane FRU PDB 2U Power distribution board, contains master chassis serial number FRU PSU 2U Power supply (1100 Watts) CRU X8,X8, XAUI, 2U PCIe Riser PCI Riser assembly for left and centre motherboard slots CRU X8, x16 2U PCIe Riser PCI Riser for right motherboard slot CRU Rack mount kit (requires tools) Rack mount kit CRU Rack Mount Kit (tooless) Rack mount kit, no tools required for installation CRU CMA Cable management arm CRU Bus Bars Power Bus Bars between PDB and Motherboard FRU PDB to MB Ribbon Cable Ribbon cable for control connections between PDB abd Motherboard FRU Light pipe kit Light pipe assemblies for left and right of disk cage FRU Motherboard assembly Motherboard assembly, part no varies depending on Core count FRU DIMMs FBDIMMs (three different part numbers for 1GB, 2GB, 4GB) CRU XAUI board optical/copper XAUI Adapter card (two different parts for copper/optical) CRU XFP module XFP GBIC module for use in XAUI cards (three different parts SR, HR, HRMM) CRU Battery Battery backup for NVRAM of Service Processor CRU HDD 73GB/146GB SAS Hard Disk drive, different part numbers for capacities CRU System Configurations PROM System Configuration PROM FRU Maramba Cable Kit SAS Cable kit FRU Sun Internal and Approved Partners Only 51
  52. 52. Option Parts List for T5140/T5240 Part Number Option Description Available SECY9PS41Z AC PSU 1RU (720 Watts) RR SEDY9PS51Z AC PSU 2RU (1100 Watts) RR - DC PSU 2RU (1200Watts) post-RR SESY2A1Z 2GB Memory (2x1GB) RR SESY2B1Z 4GB memory (2x2GB) RR SESY2C1Z 8GB Memory (2x4GB) RR SESY9FF1Z FB-DIMM Filler panel RR SEUY2MM1Z Memory Mezzanine Assembly 2U only RR SEU9AD1Z Memory Mezzanine Air Duct RR SETY9BA1Z 4 Disk Backplane for 1U RR SETY9BB1Z 8 Disk Backplane for 1U post-RR SEUY9BB1Z 8 Disk Backplane for 2U RR SEUY9BC1Z 16 Disk Backplane for 2U (High Line only (220VAC) RR SESY3A11Z 73GB, 10KRpm 2.5” SAS Drive RR SESY3C11Z 146GB, 10KRpm 2.5” SAS Drive RR SESX3A21Z 73GB, 15KRpm, 2.5” SAS Drive RR - SATA Drives (300,500GB) post-RR SESY9MF1Z HDD Filler Panel RR SESY9DV1Z DVD, 8X RW, Slot Load RR SESY9RK1Z Slide Rail Kit, requires screwdriver (1RU and 2RU) RR SESY9RK2Z Slide Rail Kit, Tool-less (1RU and 2RU) RR Sun Internal and Approved Partners Only 52

×