Successfully reported this slideshow.
We use your LinkedIn profile and activity data to personalize ads and to show you more relevant ads. You can change your ad preferences anytime.

Vinod Resume dt 01.01.2015

523 views

Published on

  • Be the first to comment

  • Be the first to like this

Vinod Resume dt 01.01.2015

  1. 1. CURRICULAM VITAE Vinod kumar.KANUKURTHI Mobile +91- 9177881133 vinod.kumark@yahoo.co.in BE Mechanical with 10+ Years Experience in Quality Inspection OBJECTIVE Carve a Niche in an organization and to be involved in challenging field of QA/QC Inspection, Supplier Quality Inspection & Expediting, Project engineering and quality management activity to become an important spoke of corporate. Education:  B.E in Mechanical Engineering from Chaitanya Bharathi Institute of Technology (CBIT), affiliated to Osmania University, Hyderabad. INDIA (June 2001-2005)  Diploma in Civil Engineering from Quli Qutubshah Govt. Polytechnic , Hyderabad State Board of Technical Education & Training, Andhra Pradesh, INDIA (June 1996-1999.) Professional Certifications: ASNT Level-II certificates in Non destructive testing methods in  Ultrasonic Testing  Radiographic Testing  Magnetic Particle Testing  Die Penetrant Testing Work Experience: (Overall Total 10+ years) 1. M/s. Air Liquide Global E&C Solutions., Delhi, INDIA as Dy. Manager -Supplier Quality Inspection & Expediting (Aug 2012 – Till date) AIR LIQUIDE a France based company is world leader in gases, technologies and services for Industry and Health Present in 80 countries. Air Liquide Global E&C Solutions (Global engineering and construction Solutions) is a world business unit of the Air Liquide Group and technology partner of choice for the design, engineering and construction of leading-edge processing facilities and related infrastructures worldwide. Role & Responsibilities:  Handling complete inspection activities of a project & Reporting to Lead Inspection Manager of procurement department.  Co ordination with Project team for smooth execution of Project inspections  Attending Kick off meeting/ pre manufacturing meeting (PIM) at suppliers  Preparation of Inspection data Sheet (IDS) in line with project requirement during enquiry stage of Purchase order to suppliers.  Approval of Quality Assurance Plans/Inspection Test Plans, Welding documents & NDE procedures.  Inspection of various equipments & items of project like cold box structures, APU Skid modules, Pr.Vessels, Columns, Compressors, Heat exchangers, cryogenic tanks, Control valves,Manual Valves, pipes, fittings, Forgings, Fasteners,Bulk items, Pressure & temperature gauges,Temp Elements ,Transmitters Flow meters, Instruments, Cooling Towers, Pumps, Structural steels, etc.  Witness of Inspection & testing activities at manufacturing units as per Inspection Test plans  Preparation of Inspection Visit reports for the inspection carried out & also un safety practices will be recorded.  Review of Supplier documents/MTC’s and issue of Inspection Release Note.  Discussions with Respective Engineering departments to sort out any Quality issues/Deviations  Compiling of Manufacturers’ Data Report (Final Quality Documents) in line with project requirement & submission to Client. Page 1 of 7 Updated on Dt. 01.01.2015
  2. 2.  Verification of Purchase requisitions according to project specifications & applicable codes.  Dual Inspection carried out with Equipment Experts  Preparation of Monthly Inspection progress Reports.  Evaluation & Qualification Audits of new suppliers for Vendor development  Co ordination with Third Party Inspection agencies for arranging inspections & Clarifications.  Verifying Inspectors are qualified/able to cover scope of work  Reviewing inspection reports for sufficient detail to cover PO requirements and ensuring necessary actions are taken to resolve reported issues and NCRs  Monitoring the issuance & coordination of the resolution of Project NCRs and Corrective Action Requests  Lessons Learned transfer from previous projects and identifying new lessons learned during project activities  Ensuring all delivery consignments are inspected prior to release for shipment  Co ordination with imported vendors & indigenous Vendors for Quality issues & expediting.  Carry out a workshop tour in order to survey the fabrication status and to ascertain if the Supplier will be capable to meet the Contractual delivery dates  Expediting of manufacturing progress & follow up with suppliers to meet the delivery within Contractual delivery.  Issuing of despatch instructions & coordinating for despatch of consignments with suppliers. Projects Handled at Airliquide Global E&C Solutions: 1. Client -RELIANCE, Dahej , Project: 240 TPD (Air Separation Plant for OSBL Project) Role: Project Supplier Quality Inspector 2. Client -Godrej Industries Ltd , Project: 250 TPD Fat splitting & 110TPD Glycerine water Evaporation Plant Role: Project Supplier Quality Inspector & Expeditor 3. Client – GASAL, Qatar Project: 2450 TPD (Air Separation Plant) supplying to SHELL PETCHEM & SHELL PEARL Role: Project Supplier Quality Inspector 2. M/s. TUV SUD South Asia Pvt. Ltd., Hyderabad, INDIA as Sr.Inspection Engineer. (Feb 2006 – Aug 2012 ) TÜV SÜD is a global international service corporation focusing on testing, inspection, Certification and Training at over 800 locations, primarily in Europe, North America, Asia Pacific, TÜV SÜD Group Employs approximately 19,000 staff. TÜV SÜD Group is headquartered in Munich, Germany  Carried out Third party inspections for Various Items like Valves, pipes, Tubes, Fasteners, Plates, Structural steel, Fittings, Castings, Forgings, Shafts, MDPE pipes, PVC pipes, Gas Metering Skids, Regulators, PEB Structures, Pr Gauges, Hand pumps, Gas compressors, Drive Turbine & other products at following Vendor Premises. Items Vendors Client/Owner Valves: Inspection of Pressure Relief valves, Flow control valves, LPG Cylinder Valves, Gate valves, Globe valves, Swing Check Valves, Ball valves, Wafer check valves, Plug valves, Safety Valves, Control Valves as per A216, A217, A351 Gr.CF8, CF8M , A105 etc. 1 Audco India Ltd, Chennai 2. Microfinish Valves, Hubli. 3. Weir BDK Valves, Hubli. 4. NSSL valves, Nagpur. 5. Belgaum Aqua valves, Belgaum. 6. MIL control valves 7. Trans valves, Hyderabad 8. Hawa valves, Hubli. 9. Gadge Patil Industries, Kolhapur 10. Severn Glocon, Chennai 11. Niton valves 12. Flow Serve 13. Fainger Lesser 14. Advance Valves IOTL RMG Automation, VA-Tech Wabag Chemtrols Industries HMWSSB. L&T GAIL MEGHA Engg. IGL RIL Page 2 of 7 Updated on Dt. 01.01.2015
  3. 3. Pipes: Inspection of CS & SS Pipes as per API5L, A106, A53, 304L, 316L, 358 etc. 1. Maharashtra Seamless Ltd, Nagothane 2. PSL, Gandhidham & Vizag. 3. Surya Roshni Ltd. Bahadurgarh. 4. Jindal, Kosi kalan, Mathura. 5. Megha Engg & Infrastructures 6. Ratnadeep Pipes IGL, GSPL, Reliance, HMWSSB. Tubes: Inspection of SS & Brass tubes 1. CST Valinox, Hyderabad. 2. Cubex Tubings, Hyderabad 3. Swagelok Godavari Engg. Essar Refinery RIL Inspection of FRP Pr. Tubes & FRP structures 1. PENTAIR, Verna, Goa 2. Hemon cooling towers IOCL, Baurani Steel Plates: Inspection of Steel Plates as per API 5L, A516, IS2062 etc. 1. ISPAT India limited, Dolvi. 2. ESSAR 3. JSW steels GSPL Fasteners: Inspection of Fasteners as per A193, A194, A320, IS 1364 etc. 1. Hiten Fasteners, Bangalore 2. Sangamesh Fasteners, Hubli. 3. Fasteners & Allied Products, Hubli 4. Anuraj Industries Alstom Projects. Jaihind Projects NLC. Forgings: Inspection of Forgings & Shafts 1. Bay Forge India Ltd, Tamilnadu. 2. Shivaani Alloy Castings, Hyderabad 3. Engineers Enterprises, Rajnandgaon 4. UI Fittings, Hyderabad 5. CD Engineering 6. CHW forge Alstom NLC RS Associates Castings: Inspection of Castings of Valves, Chain link, Gears, Bearings, Heater tube support plates. 1. Shivaani Alloy Castings, Hyderabad 2. NSSL, Nagpur. 3. Barton Firtop, Verna, Goa. 4. Vaksh steels, Hyderabad 5. Hastalloy , Anakapalle 6. Tulip Castings, Kolhapur IOTL Chemtrols Fittings & Flanges Inspection of Fittings as per A234, A403, A105, A181 1. Gujarat infra Pvt. Ltd. 2. Lebracs Rubber Lining Pvt. Ltd. 3. UI Fittings, Hyderabad 4. Petrochem , Baroda 5. Metal Forge, Thane 6. Paras Engineering VA-Tech. RS Associates Pressure vessels Inspection of Pr. vessels 1. Technoweld, Gajuvaka , Vishakhapatnam 2. SGK Techo ventures, Pashyamylaram 3. Inox India Ltd, Kalol-Baroda 4. OMPL Baroda 5. Fabtech Engineers 6. Multimax Engineering BOC IOTL Heat Exchangers Final Inspection of Heat Exchanger 1. Godavari Engg. Hyderabad 2. Radiant Heat Exchangers 3. Fabtech Engineers 4. Multimax Engineering IOCL Gaskets Inspection of Gaskets Starflex sealings, Goa IGP Engineers Paharpur cooling towers Page 3 of 7 Updated on Dt. 01.01.2015
  4. 4. Air Pre Heater Stage inspection of Air pre heater Thermal Systems, Jeedimetla, Hyd. Paradeep Phosphates MDPE Pipes & Fittings: Online Inspection of MDPE Pipes as IS 14885 Jain Irrigation Systems, Jalgaon. Glynwed pipe systems- Goa IGL CUGL HMWS& SB Regulators: Inspection of Regulators for Skids Chemtrols Industries, Goa Kabsons Regulators, Hyd IGL SGL Gas Metering Skids FAT for Gas Metering Skids Chemtrols Industries, Goa GAIL IGL Structural Steel Inspection of Structural steel like rods, Angles, C Channels, I sections. Vandana ISPAT, Raipur Vandana Rolling Mills, Raipur Sarda Ispat , Nagpur & JSW Steel, Bellary Reliance Infra. (SASAN Project) PEB Structures Inspection of PEB Structures. Kirby Pre engineering Structures Hansan drives Sany Engg, Indo space Pr. Gauges & Temp Gauges Inspection of Pressure Gauges, Temp gauges & RTD’s Forbes marshal, Hyderabad. General Instruments, Goa. Goa Thermostatic Ltd, Goa. L&T VA Tech Paharpur cooling Insulating Material Inspection of LRB mattresses Rockwool India Ltd. Kandi, Zaheerabad IOTL Refractory Material Castwell Industries, Nagpur Petron Motors: Inspection of Electric Motors Kirloskar Electric Company Ltd, Hubli. VA-Tech High Mast Lighting System: Inspection of Lighting System Bajaj Electricals Limited, Pune. Flsmidth Centrifugal Pumps Microfinish Pumps Paradeep phosphates Rocket Motor Tubes & Fibre reinforced plastic tubes Bharat Dynamics Limited, Hyderabad Oil Country Tubular Limited, Narkatpally Allen Reinforced Plastics Pvt Ltd, Hyd Armament Research dev. Organization steam Turbine & Compressor BHEL, Hyderabad Siemens NOCL cuddalore RIL  Experience in the Field of Refinery (Plant Turnover Inspection) ♣ Project: Refinery III M&I Shutdown Jan-Feb ‘2010 Client: Chennai. (Plants: CDU, VBU & SRU) ♣ Project: M&I Shutdown Dec-2009 (Plant: CDU) Client: IOCL, Haldia. ♣ Project: M&I Shutdown Dec-2010 (Plant: CDU) Client: IOCL, Barauni ♣ Project: M&I Shutdown May-2011 (Plant: HGU, DHDT) Client: IOCL, Digboi Page 4 of 7 Updated on Dt. 01.01.2015
  5. 5. Job Scope :External and internal inspection of all type of static equipment like storage tanks, columns, vessels, piping, heat exchangers, safety valves etc.  Visual Inspection for Columns, Pressure vessels, Drums, Heat Exchangers and Piping.  Visual inspection (internal & external) of static equipment for weld /material surface discontinuities.  Pre-welding and weld joint fit-up inspection, in- process welding inspection.  Witnessing Hydro Test for Piping, Exchangers, tubes bundles, Fin fan coolers & Pressure vessels.  Witnessing Ultrasonic Thickness gauging for pipe lines, Columns, Pr. Vessels, Heat Exchangers, Drums & Nozzles.  Monitoring & Record Review of Pre Heat, Post Weld Heat Treatment and Stress Reliving activities.  Witnessing NDT like UT/PT/MT against relevant codes & standards.  Interpretation of RT Films & Review of RT Reports  Inspection of surface roughness after sand / grit blasting and measurement of paint DFT after application of each coat (primer, intermediate and finish Coat)  Witnessing Holiday test for linings & coatings  Witnessing the safety valve testing.  Witnessing of hydrostatic test and pneumatic test of piping & other equipments.  Preparation of M&I Shutdown report with observations & Recommandations.  Experience in the Field of Pipeline Project: Jamnagar Export Refinery Project Client: Reliance Marine Terminal, Jamnagar Contractor: Leighton Contractors India Pvt.Ltd. Manufacturer: PSL, Gandhidham, Gujarat. Involved in different inspection activities viz. Incoming inspection of SAW pipes, review of WPS/PQR/WPQ, witnessing welder Qualification, 3LPE coating, Concrete weight coating, PU coating for bends, material inspection & testing. Visual & dimensional inspection of fit-up and finish weld for Onshore/offshore pipeline, NDT, , Hydro test of Subsea & floating hoses, PLEM hydro testing & Preparation of all Inspection reports in line with requirements of client specifications. Project: Morbi to Mundra Gas pipe line Project (API 5L Gr.x65 -323.9mm OD x 7.1mm WT) Client: GSPL Contractor: Tehran Jonoob-Jaihind Consortium Manufacturer: Surya roshni, Bahadurgarh, Haryana. Inspection Agency: TUV SUD Involved in different inspection activities viz. Incoming inspection of coil, review of WPS/WPQ, material inspection & testing. ERW pipe welding inspection, Heat treatment, Visual & Dimensional inspection, Hydrostatic test, UT (Auto & manual), RT, Mechanical testing, Macro hardness, Impact Test, calibration of Pressure gauges, Preparation of all Inspection reports in line with requirements of client specifications, and Final Documentation. Project: Delhi City Gas Distribution Project (API 5L Gr.x65 - 4’’ NB x 6.4mm WT) Client: Indraprastha Gas Ltd. Consultant: Tractable Manufacturer: Jindal Saw Ltd (Coating div.), Kosikalan, Mathura . Inspection Agency: TUV SUD Witnessed different activities of 3LPE Coating viz. review of PQT, Visual inspection, surface roughness after blasting, Holiday test, peel off test, Impact test, Adhesion test, CD test, Indentation hardness, overall coating Page 5 of 7 Updated on Dt. 01.01.2015
  6. 6. thickness & raw material test of Epoxy, adhesive and polyethylene, Preparation of all Inspection reports in line with requirements of client specifications. Project: Gas metering stations Client: Sabarmati Gas Ltd. Gujarat Inspection Agency: TUV SUD Witnessed different activities of Piping Station viz. review of WPS, PQR, Visual inspection, Fitup check, Weld Visual DP Test , Review of RT Films, Hydrostatic test , Pneumatic Test, surface roughness after blasting, Painting & review of raw material test reports, Preparation of all Inspection reports in line with client specifications. Project: IN-Situ PUF application of 16’’ dia. Ammonia Pipe line Client: Coromandel Fertilizers, Vishakapatnam Inspection Agency: TUV SUD Witnessed different activities of IN-Situ PUF like mockup test, surface preparation, painting DFT, Aluminum sheet cladding, pouring of PUF & review of raw material test reports, Preparation of all Inspection reports in line with requirements of client specifications. Project: Krishna Drinking water supply project (Cross-Country/Plant Piping Fabrication) Client: HMWS&SB, Hyderabad. Contractors: L&T, NCC, IVRCL, Megha, KCCPL. Taher Ali. Inspection Agency: TUV SUD Length of pipeline: 110 KM (dia: 2200 & 2375mm.) Review of Raw material TC’s, Review of WPS, PQR. Visual Inspection, fit up check, Weld Visual , NDT tests like UT, RT are carried out and witnessed/reviewed. Witness of Hydro test. Documentation will be maintained for each stage of inspection witnessed/reviewed. 3. M/s. Larsen & Toubro, heavy engg.works, Hazira. as NDT Engineer.(June'05- Jan'06) As a NDT engineer through Industrial Inspection Services, I used to test and interpretation of ultrasonic testing of welding joints for different thickness for pressure vessels, Heat exchangers, piping, and welder Qualification specimens. 4. M/s. KCCPL, Hyderabad as a QC Engineer. (Aug'99 – Feb’01) (Cross-Country/Plant Piping Fabrication)  Preparing spool drawings from the main drawing.  Dimensional and fit-up inspection prior to welding.  Preparation of all Inspection reports in line with requirements of client specifications.  Co-ordination with NDT service providers of RT, UT, PT & MT.  Site work distribution and supervision.  Co-ordination with erection team for Lowering Back filling. Page 6 of 7 Updated on Dt. 01.01.2015
  7. 7. Other particulars & abilities. • Well versed with welding processes SMAW, SAW and GTAW. • Well versed with NDT methods i.e UT, DPT, MPT & RT Film Interpretation. • Familiar with International codes & standards of ASME-II, V, IX, VIII div.1, API, ASTM & BIS • Preparation of WPS & PQR. • Well versed in MS-WORD, MS-EXCEL, windows98, 2000, xp, 2007. Extra-circular activities. Holding NCC ‘C’ certificate in 2(Andhra) Air sqn.Tech. NCC, Secunderabad. My Strengths  Job knowledge  Sincere  Hard-working  Positive attitude Computer skills: MS Office 2007(Word, Excel, PPT, Outlook), windows 7, XP Personal Profile: Date of Birth : 10.10.1979 Marital Status : Married Children’s (2) : Boy & Girl Languages Known : English, Hindi & Telugu Permanent Address : H.No.17-1-181/M/15, Madannapet, Saidabad, Hyderabad, Telangana.–500059, India. Present Address : 394, Part III, Ashoka Enclave, Sector 35, Faridabad. NCR Delhi. INDIA Passport No. : Z2314765 Date of Expiry : 29.05.2022 Expected CTC : Negotiable Notice Period : 2 months (Negotiable) Mobile No : +91 9177881133 Page 7 of 7 Updated on Dt. 01.01.2015

×