Fmcat l smccb

  1. 1. circuit BreakerS MoLded caSe circuit BreakerS (MccB) 64 www.factorymation.com/circuitbreakers 162 from $ Formerly LG Industrial Systems Four Compact Frame Sizes Features: 15–125A • Internal electrical auxiliaries (auxiliaries, alarms) • Through-the-door rotary disconnect handles • Flange-mount disconnect handles • Locking devices Rated Amps TS250 150–250A Std. Breaking Capacity 15 TD125NU-FTU-LL-15 $162 TD125HU-FTU-LL-15 $239 30 TD125NU-FTU-LL-30 $162 TD125HU-FTU-LL-30 $239 125 Amp Frame 20 TD125NU-FTU-LL-40 50 TD125NU-FTU-LL-50 60 TS400 Part Number TD125NU-FTU-LL-20 40 300–400A Accessories: • UL489 Listed MCCB for Branch Circuit Protection • Breaking capacity choices: Standard, 35kA @ 480V High, 65kA @ 480V • Optimal overload protection • 600VAC maximum rated operational voltage • UL File #E191605 600VAC UL489 TD125 Susol TD and TS circuit breakers come in 4 compact frame sizes and are rated from 15 through 800 amperes. Super Solution TD125NU-FTU-LL-60 80 TD125NU-FTU-LL-80 100 TD125NU-FTU-LL-100 Price $162 $162 $162 $162 $162 $162 High Breaking Capacity Part Number TD125HU-FTU-LL-20 TD125HU-FTU-LL-40 TD125HU-FTU-LL-50 TD125HU-FTU-LL-60 TD125HU-FTU-LL-80 TD125HU-FTU-LL-100 Price Trip Unit Terminals Fixed thermal/ Fixed magnetic Line-side/ Load-side Lugs Fixed thermal/ Fixed magnetic Line-side/ Load-side Lugs $436 Fixed thermal/ Fixed magnetic Line-side/ Load-side Lugs $436 Fixed thermal/ Fixed magnetic Line-side/ Load-side Lugs Adjustable Thermal/ Fixed Magnetic Line-side/ Load-side Lugs Adjustable Thermal/ Fixed Magnetic Line-side/ Load-side Lugs $239 $239 $239 $239 $252 $252 TD125NU-FTU-LL-125 $288 TD125HU-FTU-LL-125 150 TS250NU-FTU-LL-150 $340 TS250HU-FTU-LL-150 $436 TS250NU-FTU-LL-200 $340 TS250HU-FTU-LL-200 $436 250 500–800A 125 200 TS800 TS250NU-FTU-LL-250 $340 TS250HU-FTU-LL-250 250 Amp Frame 175 TS250NU-FTU-LL-175 225 TS250NU-FTU-LL-225 400 Amp Frame $340 $340 TS250HU-FTU-LL-175 TS250HU-FTU-LL-225 $367 $436 TS400NU-FMU-LL-300 $601 TS400HU-FMU-LL-300 $897 500 TS800NU-FMU-LL-500 $1,170 TS800HU-FMU-LL-500 $1,595 800 TS800NU-FMU-LL-800 $1,300 TS800HU-FMU-LL-800 $1,772 300 400 800 Amp Frame 600 General Specifications Series Frame size (AF) TD125NU 125 TS400NU-FMU-LL-400 TS800NU-FMU-LL-600 $601 $1,170 Lead time items. Lead time 5-7 days. Call to confirm delivery. Standard Breaking Capacity TS250NU 250 TS400HU-FMU-LL-400 TS800HU-FMU-LL-600 TS400NU TS800NU 250 - 500 kcmil (2 conductor) 300 - 400 kcmil (3 conductor) AWG 14 - 1/0 600V AC 400 800 TD125HU $897 $1,595 High Breaking Capacity TS400HU TS800HU AWG 1 - 400 kcmil 250 kcmil - 500 kcmil 3/0 (2 conductor) 600V AC 600V AC 600V AC 250 - 500 kcmil (2 conductor) 300 - 400 kcmil (3 conductor) 125 TS250HU 250 400 800 AWG 14 - 1/0 AWG 1 - 400 kcmil 250 kcmil - 500 kcmil 3/0 (2 conductor) 600V AC 600V AC 600V AC 240 VAC 50/60Hz 50kA 50kA 50kA 50kA 100kA 100kA 100kA 100kA 600 VAC 50/60Hz 10kA 10kA 10kA 10kA 14kA 14kA 14kA 14kA Wire/Cable Size Rated operational voltage UL interrupting rating 480 VAC 50/60Hz Reference standard Mechanical life (operations) Electrical life (operations) Weight (lbs) 35kA 4,000 4,000 @ 600V AC 2.7 35kA 5,000 35kA UL 489, File No. E231289 1,000 @ 600V AC 12.6 5,000 1,000 @ 600V AC 12.6 35kA 3,000 500 @ 600V AC 30.0 65kA 4,000 4,000 @ 600V AC 2.7 To order call 1.800.972.0436 or visit factorymation.com 65kA 65kA UL 489, File No. E231289 5,000 1,000 @ 600V AC 12.6 5,000 1,000 @ 600V AC 12.6 600V AC 65kA 3,000 500 @ 600V AC 30.0
  2. 2. circuit BreakerS www.factorymation.com/circuitbreakers Switches Internal Accessories Part Number Price S-AL $11 Part Number Price Control Voltage Current Operating Voltage S-SHT-24 Alarm Switch Type $41 24V AC/DC 24mA 0.7–1.1Vn $14 S-AX Common use to all Susol TD and TS circuit breakers Shunt Trip Modules $41 S-SHT-12 Aux. Switch 380-500V AC/DC 2.3mA Undervoltage Trip Modules Shunt Trip 25mA 10.5mA 220-240V AC/DC $41 S-SHT-440 30mA 110-130V AC/DC $41 S-SHT-230 Alarm Switch 48V AC/DC $41 S-SHT-120 Configuration 3A@250VAC / 4A@30VDC 12V DC $41 S-SHT-48 Contact Rating Auxiliary Switch 7.5mA SPDT (1 N.O., 1 N.C.) Applicable MCCB Price Control Voltage Current Tripping Voltage $57 48V AC/DC 23mA 0.35–0.70Vn $57 24V AC/DC $57 S-UVT-120 5.8mA 380-440V AC 3.8mA 220-240V AC, 250V DC $57 440-4800V AC $57 S-UVT-410 S-UVT-460 Alarm Switch (AL) Alarm switches offer provisions for immediate audio or visual indication of a tripped breaker due to overload, short circuit, shunt trip, or undervoltage release conditions. They are particularly useful in automated plants where operators must be signaled about changes in the electrical distribution system. This switch features a closed contact when the circuit breaker is tripped automatically. In other words, this switch does not function when the breaker is operated manually. Its contact is open when the circuit breaker is reset. 3.5mA TD125 TS250 TS400 TS800 0.35–0.70Vn Module TS400TS250 TS400 TS800 TD125 TS250 Left Side Compartment AX AL AL AX AX AX AX AL SHT/ UVT *FAL SHT/ UVT SHT or UVT - 1 3 1 1 1 AX 1 1 - 2 1 AL - - *FAL - - - 1 2 AX AX AX SHT/ UVT SHT/ UVT TS800 AX Shunt Trip (SHT) The shunt release opens the mechanism in response to an externally applied voltage signal. The shunt trip includes coil clearing contacts that automatically clear the signal circuit when the mechanism has tripped. The shunt release can be installed in the left accessory compartment of the Susol TD and TS circuit-breakers. FREE Ground Shipping!* for online orders over $500 T 3 1 Right Side Compartment AX AX AX AL TS400 AL Undervoltage Trip (UVT) SHT/ *FAL UVT The undervoltage release automatically opens a circuit breaker when SHT/ UVT voltage drops to a value ranging between 35% to 70% of the line voltage. The operation is instantaneous, and after tripping, the circuit breaker cannot be closed again until the voltage returns to 85% of line voltage. The undervoltage release can be easily installed in the left accessory compartment of the Susol TD and TS circuit-breakers. AX 5.4mA TD125 TS250 TS400 TS800 Possible configuration of electrical auxiliaries Internal electrical auxiliaries common for all frames AX AX 27mA 110-130V AC/DC $57 S-UVT-230 TD125 Auxiliary Switch (AX) TD125 TS250 Auxiliary switch is for applications requiring remote “ON” and “OFF” indication. Each switch contains two contacts having a common connection. One is open and the other closed when the circuit breaker is open, and vice-versa. AL TD125 TS250 TS400 TS800 TD125 TS250 TS400 TS800 S-UVT-48 Undervoltage Trip Applicable MCCB 0.7–1.1Vn Part Number S-UVT-24 65 AX AX AX AL *FAL AX AX AX AL AL SHT/ UVT *FAL SHT/ UVT ®
  3. 3. 66 circuit BreakerS External Accessories Rotary Disconnect Handles www.factorymation.com/circuitbreakers Features • Mechanism for mounting on outside of enclosure • Padlockable provision for safety lockout • 3 shaft lengths available: 12, 16 & 24” • Shafts can be cut to length to fit your enclosure • Choose from UL Type 1, 12 or UL Type 3, 4, 4X • UL File #E223241 UL Type 4x Rotary Disconnect Handles Type 1 Type 4X Applicable Shaft Price Price Handle P/N Handle P/N MCCB Length S-EHU1-12 $64 S-EHX1-12 $78 S-EHU1-24 $77 S-EHX1-24 $101 S-EHU1-16 $70 S-EHX1-16 S-EHU2-12 $70 S-EHX2-12 S-EHU2-24 $83 S-EHX2-24 S-EHU3-16 $90 S-EHU2-16 S-EHU3-12 S-EHU3-24 $77 S-EHX2-16 Flange-mount Handles and Cables $98 $104 S-EHX3-12 $96 S-EHX3-24 $110 S-EHX4-16 $134 S-EHX3-16 $128 S-EHX4-12 S-EHU4-24 $140 S-EHX4-24 $134 Flange Handles Features $84 $83 S-EHU4-12 S-EHU4-16 $95 $86 $104 $116 $140 12 inch TD125 16 inch 24 inch 12 inch TS250 16 inch 24 inch 12 inch TS400 16 inch 24 inch 12 inch TS800 16 inch 24 inch Part Number Price Applicable MCCB Type Rating S-FH2 $101 TS250 1, 12, 3R S-FH4 $154 Part Number Price S-FC2-48 • Cable-operated disconnect handle for flange mount • Flexible cable allows for easy installation • Padlockable for safety lockout • 4 cable lengths available: 36, 48, 60 & 72” • Cable sold separately • UL Type 1, 12, 3R $38 $91 S-FH1 $117 S-FH3 Flange Cables $35 S-FC2-36 $35 S-FC4-36 $38 S-FC4-48 $41 S-FC4-60 $45 S-FC4-72 Locking Devices Removable locking device • Easily attaches to the MCCB • Allows handle to be locked in “OFF” position which guarantees isolation according to UL489 • 3 padlocks may be used with shackle diameters ranging from 0.2” - 0.3” (not supplied) Mechanical Interlock Device • Prevents simultaneous closing of the two breakers • Interlock attaches directly to the cover • Front interlocking plate allows installation of a padlock in order to fix the position TS400 Applicable MCCB Cable Length TD125, TS250 36 inch TS400, TS800 36 inch TD125, TS250 TS400, TS800 60 inch TS400, TS800 72 inch Removable Locking Device, TS250 S-PL3 $19 S-PHL1 $14 $40 $80 $95 S-PL4 S-PHL2 MIT43 $21 $16 $41 $89 $99 Removable Locking Device, TD125 Removable Locking Device, TS400 Removable Locking Device, TS800 Fixed Locking Device, TD125 Fixed Locking Device, TS250 Fixed Locking Device, TS400 Fixed Locking Device, TS800 Mechanical Interlock Assembly, TD125 Mechanical Interlock Assembly, TS250 Mechanical Interlock Assembly, TS400 Mechanical Interlock Assembly, TS800 Left MCCB: ON/OFF is possible Right MCCB: Off lock Left MCCB: Off lock Right MCCB: ON/OFF is possible Left MCCB: Off lock lock Left MCCB: Off Right MCCB: ON/OFF is possible Right MCCB: ON/OFF is possible Both MCCBs are offare off locked Both MCCBs locked Operation Operation • Easily attaches to the MCCB 0.2 - 0.3inch (5 - 8mm) • Allows handle to be locked in “ON” or “OFF” 0.2 - 0.3inch position. Locking in “OFF” position guarantees (5 - 8mm) isolation according to IEC 60947-2 • 3 padlocks may be used with shackle diameters ranging from 0.2” - 0.3”(not supplied) To order call 1.800.972.0436 or visit factorymation.com 48 inch TS400, TS800 $16 $14 MIT33 0.2 - 0.3inch (5 - 8mm) 48 inch S-PL2 S-PL1 MIT23 Left MCCB: ON/OFF is possible Left MCCB: ON/OFF is possible Right MCCB: Off lock lock Right MCCB: Off 1, 12, 3R Description MIT13 Fixed locking device 1, 12, 3R TS800 Price S-PHL4 0.2 - 0.3inch (5 - 8mm) 1, 12, 3R Part Number S-PHL3 Operation TD125 Both MCCBs are off lock
  4. 4. circuit BreakerS www.factorymation.com/circuitbreakers Susol MCCB Characteristic Curves TD125 Frame TS250 Frame 10000 10000 150 50 2000 1000 400 Minute FTU:Ir=1× In FMU:Ir=0.8~1× In 700 200 1000 100 700 1000 3 100 60 60 1 10 10 0.8 1 2 3 4 5 6 7 8 10 20 30 40 50 70 100 200 40 50 50 Second 10000 5000 120 100 50 120 100 50 Minute Minute 10 7 2 0.8 1 2 3 4 3 5 4 6 7 8 10 5 6 7 8 10 20 30 20 40 50 70 30 40 50 100 70 100 200 300 200 60 1 FTU/FMU:Im=10 × In 5 6 7 8 10 30 40 40 50 50 20 30 40 50 70 100 200 300 100 FTU:Ir=1 × In FTU:Ir=1 × In FMU:Ir=0.8~1× In FMU:Ir=0.8~1× In 10 20 30 40 50 50 150 100 50 0 Ambient temperature (40°C) 0 10 10 20 20 30 30 40 1 FTU/FMU:Im=10× In FTU/FMU:Im=10× In 0.1 pressure tripping pressure tripping t 10ms t 10ms 0.01 0.001 0.001 0.5 0.5 0.8 1 0.8 1 X Normal Current In (I/Ir) FREE Ground Shipping!* for online orders over $500 2 2 3 4 3 40 50 50 Ambient temperature (40°C) Ambient temperature (40°C) 10 10 0.01 0.001 150 0 60 60 0.1 pressure tripping t 10ms 0.01 150 10000 1 Second Second 1 4 30 Second 10 Operating time Operating time 1 3 20 Temp. Characteristic 100 50 100 2 20 300 200 3 200 3 100 0.8 1 0.8 1 100 1000 1000 700 10 700 400 7 400 200 0.5 10 pressure tripping t 10ms 2000 2000 FTU:Ir=1 × In FMU:Ir=0.8~1× In 0.1 10 In:15A -> Im=400A In:20A -> Im=400A In:30A In FTU/FMU:Im=10 × -> Im=400A In:40A -> Im=400A FTU/FMU:Im=10× In Min. 400A 5000 5000 50 2000 400 0 Ambient temperature (40°C) Ambient temperature (40°C) TS800 Frame 1000 700 50 0 X Normal Current In (I/Ir) X Normal Current In (I/Ir) 10000 Operating time 30 1 0.5 TS400 Frame 1 20 100 10 0.001 0.001 0.5 300 X Normal Current In (I/Ir) 3 10 0.01 0.01 0.001 0.5 10 7 0 60 0.1 0.1 0.01 120 100 100 50 1 In:15A -> Im=400A In:20A -> Im=400A In:30A -> Im=400A In:40A -> Im=400A FTU/FMU:Im=10× In Min. 400A 0.1 200 Second Second 1 100 Ambient temperature (40°C) Operating time Operating time Operating time 1 400 150 Rated current compensation ratio (%) Rated current compensation ratio (%) 1 400 200 3 100 FTU:Ir=1 × In FTU:Ir=1× In FMU:Ir=0.8~1 × In FMU:Ir=0.8~1× In 700 10 10 7 7 Rated current compensation ratio (%) 3 Rated current compensation Rated current ratio (%) compensation ratio (%) 2000 Minute Minute Rated current compensation ratio (%) 50 2000 10 7 150 120 5000 100 120 5000 100 5000 50 Minute Temp. Characteristic 10000 120 100 67 4 5 6 7 8 10 5 6 7 8 10 20 20 30 40 50 70 30 40 50 70 100 100 200 200 300 300 X Normal Current In (I/Ir) X Normal Current In (I/Ir) ®
  5. 5. 68 circuit BreakerS www.factorymation.com/circuitbreakers Susol MCCB Dimensions TD125 Frame TS250 Frame 3.385 (86) 3.035 (77.1) 2.952 (75) 2.958 (75.15) 4.133 (105) 7.007 (178) 2.716 (69) 2.362 (60) 2.362 (60) 6.456 (164) 2.716 (69) 3.937 (100) 3.543 (90) 3.389 (86.1) 0.578 (14.7) 3.496 (88.81) 0.629 (16) 3.625 (92.1) Dimensions : inch [mm] 4.212 (107) 3.546 (90.1) 3.661 (93) Dimensions : inch [mm] TS800 Frame TS400 Frame 4.318 (109.7) 5.846 (148.5) 5.511 (140) 4.33 (110) 8.267 (210) 3.838 (97.5) 5.511 (140) 3.149 (80) 1.082 (27.5) 4.645 (118) 4.685 (119) 4.842 (123) Dimensions : inch [mm] 3.543 (90) 3.279 (83.3) 1 (25.4) 16.85 (428) 11.496 (292) 6.353 (166) 4.015 (102) 3.11 (79) 4.566 (116) 5.039 (128) 6.181 (157) 5.314 (135) Dimensions : inch [mm] To order call 1.800.972.0436 or visit factorymation.com 7.775 (197.5)

×