  1. 1. ED34-862 Specifications 2. Specifications Ceiling Suspended Cassette Type Indoor Unit FXUQ71MAV1 FXUQ100MAV1 FXUQ125MAV1 Model Connection Unit BEVQ71MAVE BEVQ100MAVE BEVQ125MAVE kcal/h 7,100 10,000 12,500 ★1 Cooling Capacity (19.5°CWB) Btu/h 28,300 39,600 49,500 kW 8.3 11.6 14.5 ★2 Cooling Capacity (19.0°CWB) kW 8.0 11.2 14.0 Casing Color White (10Y9/0.5) White (10Y9/0.5) White (10Y9/0.5) Dimensions: (H×W×D) mm 165×895×895 230×895×895 230×895×895 Coil (Cross Rows×Stages×Fin Pitch mm 3×6×1.5 3×8×1.5 3×8×1.5 Fin Coil) Face Area m² 0.265 0.353 0.353 Model QTS48A10M QTS50B15M QTS50B15M Type Turbo Fan Turbo Fan Turbo Fan Motor Output × Number W 45×1 90×1 90×1 Fan of Units m³/min 19/14 29/21 32/23 Air Flow Rate (H/L) cfm 671/494 1,024/741 1,130/812 Drive Direct Drive Direct Drive Direct Drive Temperature Control Microprocessor Thermostat for Microprocessor Thermostat for Microprocessor Thermostat for Cooling and Heating Cooling and Heating Cooling and Heating Sound Absorbing Thermal Insulation Material Heat Resistant Foamed Polyethylene, Heat Resistant Foamed Polyethylene, Heat Resistant Foamed Polyethylene, Regular Foamed Polyethylene Regular Foamed Polyethylene Regular Foamed Polyethylene Liquid Pipes mm φ9.5 (Flare Connection) φ9.5 (Flare Connection) φ9.5 (Flare Connection) Piping Gas Pipes mm φ15.9 (Flare Connection) φ15.9 (Flare Connection) φ15.9 (Flare Connection) Connections Drain Pipe mm VP20 VP20 VP20 (External Dia. 26 Internal Dia. 20) (External Dia. 26 Internal Dia. 20) (External Dia. 26 Internal Dia. 20) Machine Weight kg 25 31 31 ★4 Sound Level (H/L) (230V) dBA 40/35 43/38 44/39 Safety Devices Thermal Protector for Fan Motor Thermal Protector for Fan Motor Thermal Protector for Fan Motor Operation Manual, Installation Operation Manual, Installation Operation Manual, Installation Manual, Drain Hose, Clamp Metal, Manual, Drain Hose, Clamp Metal, Manual, Drain Hose, Clamp Metal, Standard Accessories Insulation for Fitting, Sealing Pads, Insulation for Fitting, Sealing Pads, Insulation for Fitting, Sealing Pads, Clamps, Screws, Washers, Holding Clamps, Screws, Washers, Holding Clamps, Screws, Washers, Holding Plate. Plate. Plate. Drawing No. C : 4D045395A Notes: ★1 Indoor temp. : 27°CDB, 19.5°CWB / outdoor temp.: 35°CDB / Equivalent piping length: 7.5m, level difference: 0m. Conversion Formulae 12 ★2 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp.: 35°CDB / Equivalent piping length: 7.5m, level difference: 0m. kcal/h=kW×860 3 Capacities are net, including a deduction for cooling (an additional for heating) for indoor fan motor heat. Btu/h=kW×3412 ★4 Anechoic chamber conversion value, measured at a point 1.5m downward from the unit center. These values are normally somewhat higher cfm=m³/min×35.3 during actual operation as a result of ambient conditions. 5 Refer to page 391 for Fan Motor Input.Please purchase PDF Split-Merge on www.verypdf.com to remove this watermark. FXUQ-MA 383
  2. 2. Specifications ED34-862 BEV Units Model BEVQ71MAVE BEVQ100MAVE BEVQ125MAVE Power Supply 1 Phase 50Hz 220~240V 1 Phase 50Hz 220~240V 1 Phase 50Hz 220~240V Casing Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate Dimensions: (H×W×D) mm 100×350×225 100×350×225 100×350×225 Sound Absorbing Thermal Insulation Flame and Heat Resistant Foamed Flame and Heat Resistant Foamed Flame and Heat Resistant Foamed Material Polyethylene Polyethylene Polyethylene Indoor Liquid Pipes 9.5mm (Flare Connection) 9.5mm (Flare Connection) 9.5mm (Flare Connection) Unit Gas Pipes 15.9mm (Flare Connection) 15.9mm (Flare Connection) 15.9mm (Flare Connection) Piping Connection 9.5mm (Flare Connection) 9.5mm (Flare Connection) 9.5mm (Flare Connection) Outdoor Liquid Pipes Unit Suction Gas Pipes 15.9mm (Flare Connection) 15.9mm (Flare Connection) 15.9mm (Flare Connection) Machine Weight (Mass) kg 3.0 3.0 3.5 Installation manual, Gas piping Installation manual, Gas piping Installation manual, Gas piping Standard Accessories connections, Insulation for fitting, connections, Insulation for fitting, connections, Insulation for fitting, Sealing material, Clamps Sealing material, Clamps Sealing material, Clamps Drawing No. 4D045387A 4D045387A 4D045388A Connection Example Transmission 1. Wiring Work line •The connecting line between SkyAir Indoor Unit Power supply – BEV Unit : 3 cores…like a Transmission Line Control line Wiring •BEV Unit’s power supply line; Single phase 2 line…like a VRV Indoor unit •BEV Unit – other VRV indoor unit or outdoor unit – : 2 cores…DIII network wiring (super wiring) BRC1C62 2. Piping work SkyAir side,Outdoor Unit Side,They are both flare connection. Consideration matter - When connecting centralized-control device, it is necessary to install an interface adaptor for SkyAir series in an indoor unit. - Distance between indoor unit and –BEV unit must be within 5m. Outline figure Terminal block Gas pipe (With Thermistor, Insulation pipe cover) Piping part cover PC board SW.BOX cover Hanger (Wall surface attachment is also possible) Liquid pipe Electric valve drive part Installation pattern / maintenance 1. Level installation (It hangs by two hangers) 2. Vertical Installation Hanger bolt Liquid pipe (Wall Surface Mounted) Service space*2 Gas pipe 100 or more Installation Service space*1 Screw fixed space (x2 Screws x2 place) 150 or more Service access panel (450 x 450 ) *1; Service space for switch box. (Service access panel is required for the bottom side. When there is nothing, 350 or more spaces are required. ) *2; For electric valve drive part’s maintenance. (a control box is removed)Please purchase PDF Split-Merge on www.verypdf.com to remove this watermark. 384 FXUQ-MA

×