ATEX / IECEx
CERTIFIED

8 Series Ex de Floodlight

CAT II
ZONE 1

The 8 Series is a ‘de’ certified light fitting designed ...
Ordering and fixing options
How to select your product for ordering
Example: An 8 Series 400W SON with angle mount bracket...
Upcoming SlideShare
Loading in …5
×

Zone 1 Lighting, Hazardous Area (ATEX) - Ex de - Petrel Floodlight

792 views

Published on

Petrel hazardous area (ATEX certified) Zone 1 floodlight is extensively specified for Ex de lighting applications - Petrel hazardous area floodlights for Zone 1 lighting feature rapid re-lamping through threaded access cover, narrow/wide angle beam adjustment, symmetrical reflector and integral Ex e terminal chamber.

Petrel Hazardous Area Zone 1 Flood Light (ATEX) - Ex de
Floodlight for Hazardous Area Lighting

Hazardous area floodlights are suitable for Zone 1 lighting and feature an adjustable beam suitable for a range of hazardous area lamps from 150 watts to 500 watts. Hazardous area floodlights are ATEX certified for use with SON, MBF and tungsten lamps in Zone 1 lighting installations.

Hazardous Area Zone 1 floodlight lamp options : SON, MBI, HPMV, tungsten.

Hazardous Area, Zone 1 Certification : EEx de II 2 GD IIB T2 – T3

Zone 1 Lighting, Hazardous Area (ATEX) - Ex de - Petrel Floodlight

Benefits

Narrow/Wide beam adjustment to focus floodlight output
Low installation costs with integral 'e' terminal chamber (inexpensive glanding)
Single cast body (no junction box required), more resistant to corrosion

Options

Pole mounting
Fully angular adjustable stirrup mounting
8/150w SON-T/240/50 (150W SON version), 8/250w SON-T/240/50 (250W SON version)
8/400w SON-T/240/50 (400W SON version)
8/250w MBI-T/240/50 (250W metal halide version), 8/400w MBI-T/240/50 (400W metal halide version)
8/500w TH/240/50 (500W tungsten halogen version)
8/250w HPMV/240/50 (250W mercury vapour version), 8/400w HPMV/240/50 (400W mercury vapour version)

Features

230v 50Hz - alternative voltages and frequency.
-20°C to +55°C standard supply
Tubular : SON, MBI, HPMV, Tungsten. Symmetrical reflector fitted to all versions (lamps not provided).

Zone 1 hazardous area defines areas in which an explosive atmosphere caused by a mixture air and gases, vapours and mists is expected to occur occasionally.

Published in: Technology
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
792
On SlideShare
0
From Embeds
0
Number of Embeds
196
Actions
Shares
0
Downloads
1
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Zone 1 Lighting, Hazardous Area (ATEX) - Ex de - Petrel Floodlight

  1. 1. ATEX / IECEx CERTIFIED 8 Series Ex de Floodlight CAT II ZONE 1 The 8 Series is a ‘de’ certified light fitting designed for maximum light output offering a wide variety of lamps. It offers the following benefits:  Robust, long life Zone 1 fitting  Fast re-lamping through easy access lamping port  Large range of lamp options  Easy beam focus with in-situ wide/narrow adjustment  Accurate angled mounting using optional bracket  Certified for use in gas and dust zoned applications  Replaceable glass gives longer life  Ex e terminal chamber for lower cost glanding Typical applications Chemical sites Refineries Docks / jetties Offshore Marine Pharmaceutical Paint spray shops Grain storage Paper mills Lamp options & ‘T’ ratings Specification & options Specification Fuel storage facilities Water treatment plants Metal treatment plants Details Certification Code (Gas) Ex de IIB Gb T4 or T3 Certification Code (Dust) Lamp Type / E40 Lamp holder in all cases Ex tb IIIC Db Protection type Group II Category 2 GD Certification standards EN 60079, EN 61241, IEC 60079, IEC 61241 500W Tungsten (110-127V, AC or DC) T3@Ta=55⁰C 500W Tungsten (220-250V AC or DC) Ex de (flameproof, increased safety) ATEX / IECEx type class Certificate(s) 8 Series ‘T’ rating All certified Ex de IIB (gas) and Ex tb IIIC (dust) T3@Ta=50⁰C 250W SON (110V 50Hz) T4@Ta=40⁰C 250W SON (127V 60Hz) T4@Ta=40⁰C SIRA01ATEX1035, IEC Ex SIR09.0030 Suitable zoned areas Zone 1 and Zone 2, Zone 21 and Zone 22 Gas group suitability IIA and IIB -20⁰C to 55⁰C - see lamp types 250W SON/MBI (up to) (210-250V 50Hz) T3@Ta=55⁰C Ambient range (max) Marine grade corrosion resistant aluminium body and covers with tough Borosilicate glass 250W SON/MBI (up to) (220-277V 60Hz) T3@Ta=55⁰C 400W SON/MBI (210-250V 50Hz) T3@Ta=40⁰C 400W SON/MBI (220-277V 60Hz) T3@Ta=40⁰C 250W HPMV (up to) (210250V 50Hz) T3@Ta=55⁰C 250W HPMV (up to) (220277V 60Hz) T3@Ta=55⁰C 400W HPMV (210-250V 50Hz) T3@Ta=40⁰C 400W HPMV (220-277V 60Hz) T3@Ta=40⁰C Material Ingress protection (IP rating) Cable Entries Electrical connections Control Gear Supply voltage Installation / Mounting Re-lamp access IP66 2 x M20—ISO (1 plugged) as standard. Other threads available. 2 2 wire and earth. Cable size 6mm max with looping facility Integral within the luminaire with power correction where fitted 110-270V 50/60 Hz see lamp options Direct to rear of body, optional graduated angle bracket, or optional pole mount kit Via threaded lamp cover Weight 29kg to 31 kg depending on lamp type Options Details Ballast Available as spares for models where fitted Stirrup mount bracket For accurate angled mounting (Option SM) Pole mount kit Easy lamp access Beam adjustment Adjustable bracket option Sturdy pole mounting bracket kit (Option PM) www.petrel-ex.co.uk Tel: +44 (0)191 490 1547 Fax: +44 (0)191 477 5371 Email: northernsales@thorneandderrick.co.uk Website: www.cablejoints.co.uk www.thorneanderrick.co.uk
  2. 2. Ordering and fixing options How to select your product for ordering Example: An 8 Series 400W SON with angle mount bracket for use in the UK Model / Lamp type / Mains voltage / Mains frequency / Options 8 400WSON 240 50Hz SM Product code required is: 8/ 400WSON / 240 / 50 / SM Photometric data available contact for details Fixing & Dimensions Pole mount bracket available Shown with optional angle mount bracket, all dimensions in mm Also available from Petrel Zone 1 Wellglass Zone 2 Floodlight Zone 2 Fluorescent Industrial Bulkhead Representation worldwide Hazardous area control equipment www.petrel-ex.co.uk A Chamberlin plc company Tel: +44 (0)191 490 1547 Petrel Limited 477 5371 Fax: +44 (0)191 Birmingham, B33 0LB United Kingdom 22 Fortnum Close, Kitts Green, Email: northernsales@thorneandderrick.co.uk T +44 (0)121 783 7161 • F +44 (0)121 783 5717 • E sales@petrel-ex.co.uk • W www.petrel-ex.co.uk Website: www.cablejoints.co.uk Registered No. 1539429 England www.thorneanderrick.co.uk Registered Office: Chuckery Road, Walsall WS1 2DU • VAT No. GB 695 8648 58

×