Agenda
• Introduction
• Power save study
• Implementation s...
Teleste Proprietary. All rights reserved. Company confidential
Introduction
Teleste Proprietary. All rights reserved. Company confidential
Capabilities vs utilisation
Teleste Proprietary. All rights reserved. Company confidential
Saving potential
RF amplifier components consume 70% of
all...
Teleste Proprietary. All rights reserved. Company confidential
The core idea of Teleste solution
Many optical nodes and am...
Teleste Proprietary. All rights reserved. Company confidential
Three novel options to save power in practice
#1
Remotely a...
Teleste Proprietary. All rights reserved. Company confidential
#1 Remotely adjusted performance levels
• Power save modes ...
Teleste Proprietary. All rights reserved. Company confidential
#2 Autonomous performance adjustment
• Power save modes are...
Teleste Proprietary. All rights reserved. Company confidential
#3 Load-based performance adjustment
• RPD analyses total R...
Teleste Proprietary. All rights reserved. Company confidential
Power Save Study
Teleste Proprietary. All rights reserved. Company confidential
Power save
function
RPD node
(4 active outputs)
Coaxial cab...
Teleste Proprietary. All rights reserved. Customer confidential
47 dBmV
Reference load (full spectrum)
Channel load in use...
Teleste Proprietary. All rights reserved. Customer confidential
47 dBmV
Reference load (full spectrum)Reference load - 2.5...
Teleste Proprietary. All rights reserved. Customer confidential
47 dBmV
Reference load (full spectrum)Reference load - 2.5...
Teleste Proprietary. All rights reserved. Company confidential
RPD + 3 line extender performance results
(Source MER: ~49....
Teleste Proprietary. All rights reserved. Company confidential
Power save
implementation
status
Teleste Proprietary. All rights reserved. Company confidential
#1 Remotely adjusted performance levels
• Teleste’s all cla...
Teleste Proprietary. All rights reserved. Company confidential
#2 Autonomous performance adjustment
• Power save trigger l...
Teleste Proprietary. All rights reserved. Company confidential
#3 Load-based performance adjustment
• RPD node platforms s...
Teleste Proprietary. All rights reserved. Company confidential
Saves money, energy and nature
Makes sense, right?
Teleste power saving innovation - Reduce operational costs and save nature
Upcoming SlideShare
Loading in …5
×

of

Teleste power saving innovation - Reduce operational costs and save nature Slide 1 Teleste power saving innovation - Reduce operational costs and save nature Slide 2 Teleste power saving innovation - Reduce operational costs and save nature Slide 3 Teleste power saving innovation - Reduce operational costs and save nature Slide 4 Teleste power saving innovation - Reduce operational costs and save nature Slide 5 Teleste power saving innovation - Reduce operational costs and save nature Slide 6 Teleste power saving innovation - Reduce operational costs and save nature Slide 7 Teleste power saving innovation - Reduce operational costs and save nature Slide 8 Teleste power saving innovation - Reduce operational costs and save nature Slide 9 Teleste power saving innovation - Reduce operational costs and save nature Slide 10 Teleste power saving innovation - Reduce operational costs and save nature Slide 11 Teleste power saving innovation - Reduce operational costs and save nature Slide 12 Teleste power saving innovation - Reduce operational costs and save nature Slide 13 Teleste power saving innovation - Reduce operational costs and save nature Slide 14 Teleste power saving innovation - Reduce operational costs and save nature Slide 15 Teleste power saving innovation - Reduce operational costs and save nature Slide 16 Teleste power saving innovation - Reduce operational costs and save nature Slide 17 Teleste power saving innovation - Reduce operational costs and save nature Slide 18 Teleste power saving innovation - Reduce operational costs and save nature Slide 19 Teleste power saving innovation - Reduce operational costs and save nature Slide 20 Teleste power saving innovation - Reduce operational costs and save nature Slide 21 Teleste power saving innovation - Reduce operational costs and save nature Slide 22
Upcoming SlideShare
What to Upload to SlideShare
Next
Download to read offline and view in fullscreen.

0 Likes

Share

Download to read offline

Teleste power saving innovation - Reduce operational costs and save nature

Download to read offline

Presentation by Rami Kimari, VP of HFC business, at Teleste customer seminar in Maastricht, March 2019

Related Books

Free with a 30 day trial from Scribd

See all
  • Be the first to like this

Teleste power saving innovation - Reduce operational costs and save nature

  1. 1. Teleste Proprietary. All rights reserved. Company confidentialTeleste Proprietary. All rights reserved. Company confidential Teleste’s power-saving innovation - Reduce operational costs and save nature Customer Seminar April 5, 2019, Maastricht Rami Kimari VP, HFC business
  2. 2. Teleste Proprietary. All rights reserved. Company confidential Agenda • Introduction • Power save study • Implementation status
  3. 3. Teleste Proprietary. All rights reserved. Company confidential Introduction
  4. 4. Teleste Proprietary. All rights reserved. Company confidential Capabilities vs utilisation
  5. 5. Teleste Proprietary. All rights reserved. Company confidential Saving potential RF amplifier components consume 70% of all power in outside plants Our solution saves up to 30% of power used by the RF amplifier components  Save up to 20% of your cable network power consumption
  6. 6. Teleste Proprietary. All rights reserved. Company confidential The core idea of Teleste solution Many optical nodes and amplifiers are optimised for a speculative situation: • Full RF load • Maximum signal levels In practice: • Highest frequencies are not used • Required RF levels are lower than maximum
  7. 7. Teleste Proprietary. All rights reserved. Company confidential Three novel options to save power in practice #1 Remotely adjusted performance levels #2 Autonomous performance adjustment #3 Load-based performance adjustment
  8. 8. Teleste Proprietary. All rights reserved. Company confidential #1 Remotely adjusted performance levels • Power save modes are used to set optimal amplifier bias current based on the total RF load • Modes are enabled by operators, locally or remotely
  9. 9. Teleste Proprietary. All rights reserved. Company confidential #2 Autonomous performance adjustment • Power save modes are used to set optimal amplifier bias current based on total RF load • Linear and dynamic power save modes are enabled automatically • No need for local or remote access
  10. 10. Teleste Proprietary. All rights reserved. Company confidential #3 Load-based performance adjustment • RPD analyses total RF load • Analysis is used to set right amplifier bias current, leading to optimal power consumption • Operation is autonomous
  11. 11. Teleste Proprietary. All rights reserved. Company confidential Power Save Study
  12. 12. Teleste Proprietary. All rights reserved. Company confidential Power save function RPD node (4 active outputs) Coaxial cables (resistive loss) Line extenders (1 active output) TOTAL Disabled 150 W 60 W 476 W 686 W Power Save Study - RPD node + 3 line extender amplifiers Enabled 112 W 35 W 364 W 511 W -26% RPD NODE: 4 active outputs (ICON9000) LINE EXTENDER AMPs: 7 amps (E3) / node output => 28 pcs in total 53 dBmV @ 1.2 GHz 47 dBmV @ 1.2 GHz
  13. 13. Teleste Proprietary. All rights reserved. Customer confidential 47 dBmV Reference load (full spectrum) Channel load in use (levels at line extender output)
  14. 14. Teleste Proprietary. All rights reserved. Customer confidential 47 dBmV Reference load (full spectrum)Reference load - 2.5 dB Channel load in use (levels at line extender output)
  15. 15. Teleste Proprietary. All rights reserved. Customer confidential 47 dBmV Reference load (full spectrum)Reference load - 2.5 dBReference load - 5.3 dB Channel load in use (levels at line extender output)
  16. 16. Teleste Proprietary. All rights reserved. Company confidential RPD + 3 line extender performance results (Source MER: ~49.5 dB) 16 Power [W] SC-QAM 256 114 MHz SC-QAM 256 634 MHz OFDM 1024 738 MHz OFDM 1024 930 MHz OFDM 1024 1122 MHz MER BER MER BER MER BER MER BER MER BER Max. 47.0 <10-9 45.0 <10-9 45.1 <10-9 44.6 <10-9 43.6 <10-9 -26% 42.6 2.7x10-9 38.5 2.2x10-7 38.8 <10-9 39.3 <10-9 40.4 <10-9 Max. 47.2 <10-9 45.3 <10-9 45.5 <10-9 45.5 <10-9 -26% 45.7 <10-9 42.4 <10-9 42.4 <10-9 43.5 <10-9 Max. 47.6 <10-9 45.7 <10-9 46.0 <10-9 -26% 47.2 <10-9 44.8 <10-9 45.1 <10-9
  17. 17. Teleste Proprietary. All rights reserved. Company confidential Power save implementation status
  18. 18. Teleste Proprietary. All rights reserved. Company confidential #1 Remotely adjusted performance levels • Teleste’s all classical HFC node and amplifier platforms include 2 step based (enabled/disabled) power save function • Remote control is available with transponders (DOCSIS/HMS) and coming with unidirectional RIS control • Compact line extender amplifier (E3) is the first design that supports power save control with RIS receiver
  19. 19. Teleste Proprietary. All rights reserved. Company confidential #2 Autonomous performance adjustment • Power save trigger level is defined for compact line extender amplifier (E3) • Broadband RF load power meter module (E62) has a release candidate • RIS module (E62) supports remote control and software update • Further platform implementations are under discussions
  20. 20. Teleste Proprietary. All rights reserved. Company confidential #3 Load-based performance adjustment • RPD node platforms support adjustable power save function • RPD module will report load content information in Q2/2019 • Knowledge of load information and adjustable power save function will be implemented to 4 active output strand mounted node platform (ICON9000) during Q2/2019 • Further platform implementations are under discussions (DAN300, AC9100 NEO)
  21. 21. Teleste Proprietary. All rights reserved. Company confidential Saves money, energy and nature Makes sense, right?

Presentation by Rami Kimari, VP of HFC business, at Teleste customer seminar in Maastricht, March 2019

Views

Total views

452

On Slideshare

0

From embeds

0

Number of embeds

40

Actions

Downloads

4

Shares

0

Comments

0

Likes

0

×