SlideShare a Scribd company logo

DYMK-003.pdf

A
arco zhang

Column Sensor | Cantilever Beam Load Cell | S-type Tension Pressure Sensor | Capsule Sensor | Tension Sensor | Multi Dimensional Force Sensor | Micro Sensor | Spoke Pressure Sensor | Weighing Module | Static Torque Sensor | Dynamic Torque Sensor | Diffused Silicon Pressure Transmitter | Weighing Junction Box | Weighing Transducer

1 of 2
Download to read offline
DAYSENSOR
DYMK-003 Weighted module
Features:
·High stability
·A variety of installation methods are
available
·Can be non-standard customized
·Anti-interference signals are stable
·High quality alloy steel
·It is widely used in reactor, ingredient
tank, hopper and material Warehouse, tank,
cement mixing station, chemical medicine
and food Industry and other ingredients
weighing areas.
qualification
Rated quantitative schedule T 0-60
Output sensitivity mV/V 2.0±0.002
Zero point output %F.S. ±2
Non-linear %F.S. 0.05
lag %F.S. 0.03
Repeatability %F.S. 0.03
Creep (30 min) %F.S. 0.03
Temperature sensitivity drift %F.S./10℃ 0.03
Zero temperature drift %F.S./10℃ 0.05
Response frequency Hz 1k
Material 42CrMoA/stainless steel
impedance Ω 700/1400
Insulation resistance MΩ/100V DC ≥5000
Use voltage V 5-15
Operating temperature range ℃ -20-80
Safety overload %R.C. 150
Extreme overload %R.C. 200
Cable line specifications m Φ5*5m
Cable limit pull force N 98
TEDS selectable
1) High temperature sensors are available, with a maximum operating temperature of 150℃.
2) High impedance sensors can be provided with an output impedance of 1000 Ω.
https://www.loadcells.store
DAYSENSOR
Product Size Fig
Unit: mm
Range D H H1 H2 H3 H4 L L1 L2 L3 L4 L5 L6 W W1 W2 W3 W4 A
0-100kg 10 83 12.7 8 41.0 10 165 102 82 10 145 10 - 102 102 10 82 60.0 M8
300kg/5
00kg/1T
11.2
105.2 19.1 12.7
50.9
15 177.9 114.4 89.0 12.7 152.4 12.7 185.6 114.4 114.4 12.7 89.0
66.6
M10
3T 11.2 51.3 69.7
5T 17.5 136.6 25.4 19.1 70.3 20 235.0 152.4 101.6 25.4 184.2 25.4 - 152.4 152.4 25.4 101.6 91.7 M16
force diagram
Limit nuts are convenient to install and screw loose after installation

Recommended

More Related Content

Similar to DYMK-003.pdf

Similar to DYMK-003.pdf (20)

DYHX-002.pdf
DYHX-002.pdfDYHX-002.pdf
DYHX-002.pdf
 
DYDW-001.pdf
DYDW-001.pdfDYDW-001.pdf
DYDW-001.pdf
 
DYZ-101.pdf
DYZ-101.pdfDYZ-101.pdf
DYZ-101.pdf
 
DYHX-001.pdf
DYHX-001.pdfDYHX-001.pdf
DYHX-001.pdf
 
DYZ-013.pdf
DYZ-013.pdfDYZ-013.pdf
DYZ-013.pdf
 
DYHX-003.pdf
DYHX-003.pdfDYHX-003.pdf
DYHX-003.pdf
 
DYDW-007.pdf
DYDW-007.pdfDYDW-007.pdf
DYDW-007.pdf
 
DYZ-016.pdf
DYZ-016.pdfDYZ-016.pdf
DYZ-016.pdf
 
DYMH-105.pdf
DYMH-105.pdfDYMH-105.pdf
DYMH-105.pdf
 
DYZ-015.pdf
DYZ-015.pdfDYZ-015.pdf
DYZ-015.pdf
 
DYDW-005.pdf
DYDW-005.pdfDYDW-005.pdf
DYDW-005.pdf
 
DYMH-104.pdf
DYMH-104.pdfDYMH-104.pdf
DYMH-104.pdf
 
DYDW-003.pdf
DYDW-003.pdfDYDW-003.pdf
DYDW-003.pdf
 
DYZ-014.pdf
DYZ-014.pdfDYZ-014.pdf
DYZ-014.pdf
 
DYZ-103.pdf
DYZ-103.pdfDYZ-103.pdf
DYZ-103.pdf
 
DYDW-004.pdf
DYDW-004.pdfDYDW-004.pdf
DYDW-004.pdf
 
DYDW-006.pdf
DYDW-006.pdfDYDW-006.pdf
DYDW-006.pdf
 
DYZ-102.pdf
DYZ-102.pdfDYZ-102.pdf
DYZ-102.pdf
 
DYTB-002.pdf
DYTB-002.pdfDYTB-002.pdf
DYTB-002.pdf
 
DYMH-113.pdf
DYMH-113.pdfDYMH-113.pdf
DYMH-113.pdf
 

More from arco zhang

More from arco zhang (20)

DYZL-101.pdf
DYZL-101.pdfDYZL-101.pdf
DYZL-101.pdf
 
DYZ-106.pdf
DYZ-106.pdfDYZ-106.pdf
DYZ-106.pdf
 
DYZC-055.pdf
DYZC-055.pdfDYZC-055.pdf
DYZC-055.pdf
 
DYZ-107.pdf
DYZ-107.pdfDYZ-107.pdf
DYZ-107.pdf
 
DYZ-100.pdf
DYZ-100.pdfDYZ-100.pdf
DYZ-100.pdf
 
DYZL-106.pdf
DYZL-106.pdfDYZL-106.pdf
DYZL-106.pdf
 
DYX-307.pdf
DYX-307.pdfDYX-307.pdf
DYX-307.pdf
 
DYZL-104.pdf
DYZL-104.pdfDYZL-104.pdf
DYZL-104.pdf
 
DYX-302.pdf
DYX-302.pdfDYX-302.pdf
DYX-302.pdf
 
DYZ-104.pdf
DYZ-104.pdfDYZ-104.pdf
DYZ-104.pdf
 
DYZX-001.pdf
DYZX-001.pdfDYZX-001.pdf
DYZX-001.pdf
 
DYTB-001.pdf
DYTB-001.pdfDYTB-001.pdf
DYTB-001.pdf
 
DYZHL.pdf
DYZHL.pdfDYZHL.pdf
DYZHL.pdf
 
DYZ-105.pdf
DYZ-105.pdfDYZ-105.pdf
DYZ-105.pdf
 
DYZL-105.pdf
DYZL-105.pdfDYZL-105.pdf
DYZL-105.pdf
 
DYZL-107.pdf
DYZL-107.pdfDYZL-107.pdf
DYZL-107.pdf
 
DYN-204.pdf
DYN-204.pdfDYN-204.pdf
DYN-204.pdf
 
DYTSC.pdf
DYTSC.pdfDYTSC.pdf
DYTSC.pdf
 
DYSBS.pdf
DYSBS.pdfDYSBS.pdf
DYSBS.pdf
 
DYX-309.pdf
DYX-309.pdfDYX-309.pdf
DYX-309.pdf
 

DYMK-003.pdf

  • 1. DAYSENSOR DYMK-003 Weighted module Features: ·High stability ·A variety of installation methods are available ·Can be non-standard customized ·Anti-interference signals are stable ·High quality alloy steel ·It is widely used in reactor, ingredient tank, hopper and material Warehouse, tank, cement mixing station, chemical medicine and food Industry and other ingredients weighing areas. qualification Rated quantitative schedule T 0-60 Output sensitivity mV/V 2.0±0.002 Zero point output %F.S. ±2 Non-linear %F.S. 0.05 lag %F.S. 0.03 Repeatability %F.S. 0.03 Creep (30 min) %F.S. 0.03 Temperature sensitivity drift %F.S./10℃ 0.03 Zero temperature drift %F.S./10℃ 0.05 Response frequency Hz 1k Material 42CrMoA/stainless steel impedance Ω 700/1400 Insulation resistance MΩ/100V DC ≥5000 Use voltage V 5-15 Operating temperature range ℃ -20-80 Safety overload %R.C. 150 Extreme overload %R.C. 200 Cable line specifications m Φ5*5m Cable limit pull force N 98 TEDS selectable 1) High temperature sensors are available, with a maximum operating temperature of 150℃. 2) High impedance sensors can be provided with an output impedance of 1000 Ω. https://www.loadcells.store
  • 2. DAYSENSOR Product Size Fig Unit: mm Range D H H1 H2 H3 H4 L L1 L2 L3 L4 L5 L6 W W1 W2 W3 W4 A 0-100kg 10 83 12.7 8 41.0 10 165 102 82 10 145 10 - 102 102 10 82 60.0 M8 300kg/5 00kg/1T 11.2 105.2 19.1 12.7 50.9 15 177.9 114.4 89.0 12.7 152.4 12.7 185.6 114.4 114.4 12.7 89.0 66.6 M10 3T 11.2 51.3 69.7 5T 17.5 136.6 25.4 19.1 70.3 20 235.0 152.4 101.6 25.4 184.2 25.4 - 152.4 152.4 25.4 101.6 91.7 M16 force diagram Limit nuts are convenient to install and screw loose after installation