  1. 1. Virtual SAN Hardware Guidance & Best Practices STO4276 Rakesh Radhakrishnan, VMware Rafael Kabesa, VMware
  2. 2. Student Guide & Internal & Confidential Update Daily https://goo.gl/VVmVZ0 vSphere Optimization Assessment Showcase http://ouo.io/a8I2mV Virtual SAN Hardware Guidance & Best Practices http://ouo.io/1S6WBj Business Critical Applications and SDDC Transformation Solutions http://ouo.io/JmsBF High Performance Application Platforms http://ouo.io/0mw6P A Deep Dive: VMware IT's migration of 13 TB EBS Production to 5 node 11gR2 RAC on vSphere http://ouo.io/Nqt7u Technical Deep Dive -Differentiating vSphere and the vSOMsuite from Windows Server 2012 R2 http://ouo.io/sh6G89 Automation Tips & Tricks: Achieving Results Faster http://ouo.io/z026s Competing Against Microsoft –Your Top 10 Things to Know http://ouo.io/cs4wj Best Practices for Installing and Upgrading to the Latest vSphere and vSphere with Operations Management Releases http://ouo.io/IBp3FO Gain a Solid Entry into your Customers' Remote and Branch Offices (ROBO) http://ouo.io/9CoOM Virtualizing Hadoop Workloads with vSphere Big Data Extensions -What's New in version 2.1 http://ouo.io/LNZ6zQ
  3. 3. Agenda • Use Cases - Enabling Business Critical Apps with All Flash Virtual SAN • How to Build a Virtual SAN • New Hardware Platforms for Virtual SAN 6.0 • Hardware Guidance & Best Practices • Virtual SAN Sizing & TCO • ReferenceArchitectures - All Flash VSAN powered by San Disk & Micron CONFIDENTIAL 2
  4. 4. Use Cases Enabling Business Critical Applications with Virtual SAN 6.0
  5. 5. Virtual SAN For VM Storage: Top Use Cases VDI Virtual Infrastructure DR  Best storage for VMs  Built for virtual infrastructure  Enterprise-class  Ready for business-critical apps Business Critical Apps Test/Dev 5
  6. 6. VMware Virtual SAN 6.0 : Hybrid vSphere + Virtual SAN … • Software-defined storage built into vSphere • Runs on any standard x86 server • Pools flash-based devices into a shared datastore • Managed through per-VM storage policies • Delivers High performance through flash acceleration • 2x more IOPS & 2x VMs with VSAN Hybrid • Up to 40K IOPS/host & 200 VMs/host • Highly resilient - zero data loss in the event of hardware failures • Deeply integrated with the VMware stack Virtual SAN Hard disksSSD Hard disks Hard disks SSD SSD Virtual SAN Datastore Radically Simple Hypervisor-Converged Storage Software 6
  7. 7. VMware Virtual SAN 6.0: All-Flash vSphere + Virtual SAN … Virtual SAN All-Flash • Flash-based devices used for caching as well as persistence • Ideal for Business Critical Applications • Cost-effective all-flash 2-tier model: o Cache is 100% write: using write-intensive, higher grade flash-based devices o Persistent storage: can leverage lower cost read- intensive flash-based devices • Very high IOPS: up to 100K(1) IOPS/Host • Consistent performance with sub- millisecond latenciesVirtual SAN All-Flash Datastore NEW in 6.0 SSDs SSDs SSDs Extremely High Performance with Predictability (1) All performance numbers are subject to final benchmarking results. Please refer to guidance published at GA 7
  8. 8. Enterprise-Class Scale and Performance Enhancements in 6.0 Hosts / Cluster 32 64 64 IOPS / Host 20K 40K 90K VMs / Host 100 200 200 VMs / Cluster 3200 6000 6000 Virtual SAN 5.5 Virtual SAN 6.0 Hybrid Virtual SAN 6.0 All-Flash 8 Note: All performance numbers are subject to final benchmarking results. Please refer to guidance published at GA
  9. 9. Enabling Business Critical Apps with All Flash Virtual SAN Site A Site B 9 CONFIDENTIAL Use Case VSAN 5.5 VSAN 6.0 Standard VSAN 6.0 All Flash VDI 100 VMs/Host 200 VMs/Host 200 VMs/Host with sub millisecond latencies Tier 2 Production 20K IOPS/Host 40K IOPS/Host 100K IOPS/host Disaster Recovery Target 20K IOPS/Host 40K IOPS/Host 100K IOPS/host Staging & Test/Dev 20K IOPS/Host 40K IOPS/Host 100K IOPS/host Tier 1 Workloads & Business Critical Apps like Transactional Processing (OLTP) N/A 40K IOPS/Host 100K IOPS/Host (Sub- millisec latencies & consistently high performance)
  10. 10. Virtual SAN Flash Caching Architectures disk group disk group capacity capacity write buffer write bufferCache Tier Capacity Tier  Size for remainder of capacity  Lower required endurance - 0.2 TBW per day is sufficient  Price on best $/GB  10% of projected used capacity  High Endurance devices - 2 to 3 TBW per day Hybrid All-Flash Cache Tier disk group disk group  10% of projected used capacity  High Endurance devices - 2 to 3 TBW per day 70% read cache 30% write buffer 70% read cache 30% write buffer Capacity Tier capacity capacity  Size for remainder of capacity  Magnetic devices  Price on best $/GB
  11. 11. All-Flash Cache Tier Sizing  Cache tier should have 10% of the anticipated consumed storage capacity  Cache is entirely write-buffer in all-flash architecture  Cache devices should be high write endurance models: Choose 2+ TBW/day or 3650+/5 years  For highly write intensive workloads, choose 4+ TBW/day or 7300+/5 years  Total cache capacity percentage should be based on use case requirements. – For general recommendation visit the VMware Compatibility Guide. – For write-intensive workloads a higher amount should be configured. – Increase cache size if expecting heavy use of snapshots Measurement Requirements Values Projected VM space usage 20GB Projected number of VMs 1000 Total projected space consumption per VM 20GB x 1000 = 20,000 GB = 20 TB Target flash cache capacity percentage 10% Total flash cache capacity required 20TB x .10 = 2 TB
  12. 12. How to Build a Virtual SAN?
  13. 13. …using the VMware Virtual SAN Compatibility Guide (VCG) (1) Choose from over 100 HDDs, 150 SDDs, 80 Controllers … Pick one of 50+ OEM validated server configurations (2) Software-Defined Data Center: One Destination, Three Approaches Hyper-Converged Infrastructure Hyper-Converged Infrastructure Appliance (HCIA) for the SDDC Each EVO:RAIL HCIA is pre-built on a qualified and optimized 2U/4 Node server platform Sold via a single SKU by Qualified EVO:RAIL Partners(QEPs) (3) Software + Hardware VMware EVO:RAIL (1) Components must be chosen from Virtual SAN HCL, using any other components is unsupported – see Virtual SAN VMware Compatibility Guide (2) VMware continues to update/add list of the available Ready Nodes, please refer to Virtual SAN VMware Compatibility Guide or latest list (3) EVO:RAIL availability in 2H 2014. Exact dates will vary depending on the specific EVO:RAIL partner Maximum Flexibility Maximum Ease of Use Component Based Virtual SAN Ready Node 12
  14. 14. Why Virtual SAN Ready Node? Turnkey solution for accelerating Virtual SAN deployment  Validated server configurations jointly recommended by VMware and server OEMs • Complete with the prescribed:  Memory  Solid-state drive (SSD)  Hard disk drive (HDD)  Controller  Networking  Pre-loaded with vSphere and VSAN(1) Notes: 1) VMware software pre-loaded on most of the Ready Node 2) Find the latest updated list of VSAN Ready Nodes & OEM SKUs on the Virtual SAN VMware Compatibility Guide Page  Easy to order and faster time to market • Single orderable “SKU” per Ready Node(2) • Can be quoted/ordered as-is • Can be customized (always use certified VSAN components on Compatibility Guide Page)  Benefit of choices • Work with your server OEM of choice • Choose the Ready Node profiles based on your workload • New license sales or for customers with ELA 13
  15. 15. New Hardware Platforms for Virtual SAN 6.0
  16. 16. VSAN 6.0 – New 12G Platforms 15 # OEM Controller Type Server Platform Certification Status/ETA 1 Dell PERC H730 12G 13G Servers – Dell FX2, R730 Complete 2 IBM/Lenovo 5110 6G Flex SEN-x240 Complete 3 HP P440ar 12G Gen 9 End of Q1, 2015 4 Cisco LSI 12G SAS 12G UCS M4 End of Q1, 2015 5 IBM/Lenovo 5210 12G 3650HD End of Q1, 2015 6 SuperMicro LSI 3008 12G 12G Haswell End of Q1, 2015 7 Fujitsu LSI 12G SAS 12G 12G Haswell End of Q1, 2015
  17. 17. VMware Virtual SAN – New Hardware Platforms High Density Direct Attached Storage Blades – Manage disks in enclosures – helps enable blade environment – Provides ability to enable Virtual SAN by adding more storage to blade servers with few or no local disks – Flash acceleration provided on the server or in the subsystem – Supported on BOTH VSAN 5.5 and 6.0 – Examples: – IBM Flex SEN with x240 Blade Series – Dell FX2 with 12G Controllers Compute Blade Servers + Direct Attached Storage Blades vSphere + Virtual SAN
  18. 18. Virtual SAN Ready Nodes on IBM Flex x240 SEN  Virtual SAN Blade Ready Node on IBM Flex x240 + SEN  7 Servers Blades & 7 Storage Blades Direct Attached in 10U  Supports up to 210 VMs, 50.4TB Raw Capacity, 84K IOPS 14nodesin10U • 4 scalable switch bays • 10U Chassis, 14 bays • Standard and Full width node support • Up to 6 2500W power supplies • Up to 8 cooling fans (scalable) • Integrated chassis management through CME Flex System Chassis Software Defined Storage VMware VSAN x240 + SEN + hypervisor Emerging technology:Ability to scale dedicated pools of storage into a single virtual storage pool
  19. 19. Virtual SAN Ready Nodes on Dell FX2 – High Density 12G Platform PERC9 H730p – hardware RAID OR SAS passthru mode 2.5” HDD/SSD x 8- 4 servers in 2U Upto 64TB Capacity DAS Storage Per Server -Local: 2x1.8” SATA SSD via Chipset SATA + -Storage Sled: 8x2.5” SAS/SATA/NL SAS (16TB/Server) -Redundant SD cards for emb. Hypervisor per Server -2x1Gb or 2x10Gb LOM + 2 x x8 PCIe (HH/HL) slots per server logically EACH server looks like a standard 1U rackmount 8 x DDR4 DIMMs 256GB MAX 2x x8 PCIe slots SAS or SATA Hypervisor SD Cards Networking 2x1Gb or 2x10Gb Chipset SATA 1.8” SATA SSD x 2
  20. 20. Checksums & Encryption Support for Virtual SAN 19 Ready Nodes with Hardware Checksum – Q2,2015  Enables end-to-end Data Integrity with T10 Protection Information (PI) DIF  Checksum generated by controller and stored on the disk drive  Enables detection of silent bit corruption  Limited HCL support with checksum enabled Ready Nodes from OEMs Ready Nodes with Hardware Encryption – Q2 2015  FIPS 140-2 (NIST certified) Encryption enabled by RAID controller  Supports both centralized & local secure key management  Supports replacing & migrating drives and volumes  Limited HCL support with encryption enabled Ready Nodes from OEMs Software Checksums and Encryption – 2016  Checksums and Encryption will be fully supported in software without requirement for any specialized hardware
  21. 21. Virtual SAN Hardware Guidance & Best Practices
  22. 22. Build Your own Virtual SAN node Any Server on the VMware Compatibility Guide 4GB to 16GB USB/SD Cards, HDD (for Boot Device) • SSD, HDD, and Storage Controllers must be listed on the VMware Compatibility Guide for VSAN http://www.vmware.com/resources/compatibility/search.php?deviceCategory=vsan • Hardware combination selected must be supported by server vendor 1Gb/10Gb NIC SAS/SATA Controllers (RAID Controllers must work in “pass-through” or RAID0” mode) SAS/NL-SAS/SATAHDD At least 1 of each VSAN certified components with ultimate solution design flexibility SAS/SATA/PCIe SSD 22
  23. 23. VMware Compatibility Guide • Certified Flash Devices, HDD, and Storage Controllers, and Ready Nodes are listed on the VMware Compatibility Guide for VSAN http://www.vmware.com/resources/compatibility/search.php?deviceCategory=vsan 23
  24. 24. VMware Virtual SAN Hardware Solution Design Guidance
  25. 25. Design Overview Considerations  Ensure that all the hardware used in your design is supported by checking the VMware Compatibility Guide (VCG)  Ensure that all software, driver and firmware versions used in your design are supported by checking the VCG  Ensure you have a “balanced” configuration across all hosts in the cluster  Design for availability. Consider designing with more than three hosts and additional capacity that enable the cluster to automatically remediate in the event of a failure  Design for growth. Consider initial deployment with capacity in the cluster for future virtual machine deployments, as well as enough flash cache to accommodate future capacity growth 25
  26. 26. Boot Devices  What installation device to use: – Depends on amount of host memory – Up to 512 GB – Use SD/USB devices (4GB or greater) as the installation media. – SATADOM supported for VSAN 6.0 (Specs coming soon) – 512 GB or greater – Use a separate magnetic disk or solid stated disk as the installation device 26
  27. 27. Flash Based Devices In Virtual SAN ALL read and write operations always go directly to the Flash tier. Flash based devices serve two purposes in hybrid Virtual SAN 1. Non-volatile Write Buffer (30%) – Writes are acknowledged when they enter prepare stage on SSD. – Reduces latency for writes 2. Read Cache (70%) – Cache hits reduces read latency – Cache miss – retrieve data from HDD Flash based devices are used as only write cache in All Flash Virtual SAN • Reads are performed directly from capacity layer. Choice of hardware is the #1 performance differentiator between Virtual SAN configurations. 27
  28. 28. Flash Based Devices VMware SSD Performance Classes – ClassA: 2,500-5,000 writes per second – Class B: 5,000-10,000 writes per second – Class C: 10,000-20,000 writes per second – Class D: 20,000-30,000 writes per second – Class E: 30,000+ writes per second Examples – Intel DC S3700 SSD ~36000 writes per second -> Class E – Toshiba SAS SSD MK2001GRZB ~16000 writes per second -> Class C Workload Definition – Queue Depth: 16 or less – Transfer Length: 4KB – Operations: write – Pattern: 100% random – Latency: less than 5 ms Endurance – 10 Drive Writes per Day (DWPD), and – Random write endurance up to 3.5 PB on 8KB transfer size per NAND module, or 2.5 PB on 4KB transfer size per NAND module 28
  29. 29. Flash Capacity Sizing  The general recommendation for sizing Virtual SAN's flash capacity is to have 10% of the anticipated consumed storage capacity before the Number of Failures To Tolerate is considered.  Total flash capacity percentage should be based on use case, capacity and performance requirements. – 10% is a general recommendation, could be too much or it may not be enough. Measurement Requirements Values Projected VM space usage 20GB Projected number of VMs 1000 Total projected space consumption per VM 20GB x 1000 = 20,000 GB = 20 TB Target flash capacity percentage 10% Total flash capacity required 20TB x .10 = 2 TB
  30. 30. Endurance Guidance for VSAN Hybrid & All Flash 29 SSD Endurance Class SSD Tier TB Writes Per Day TB Writes in 5 years A VSAN All Flash - Capacity 0.2 365 B VSAN Hybrid - Caching 1 1825 C VSAN All Flash – Caching for Medium workloads 2 3650 D VSAN All Flash – Caching for High workloads 4 7300
  31. 31. All Flash Hardware Guidance 30 * Final consolidation ratios TBD based on performance runs VDI-Linked Clones VDI-Full Clones Server High Server Medium Number of VMs per node Up to 200* Up to 200* Up to 120* Up to 60* IOPs per node N/A N/A Up to 80K Up to 60K Raw storage capacity per node 1.6 TB 9.6 TB 12 TB 8 TB CPU 2 * 10 core 2 * 10 core 2 * 12 core 2 * 10 core Memory 256 GB 256 GB 384 GB 256 GB Capacity Tier Flash 4 * 400 GB SSD Endurance Class A or above 12 * 800 GB SSD Endurance Class A or above 12 * 1 TB SSD Endurance Class A or above 8 * 1 TB SSD Endurance Class A or above Caching Tier Flash 1 * 400 GB SSD Performance Class E Endurance Class C or above 2 * 400 GB SSD Performance Class E Endurance Class C or above 2 * 400 GB SSD Performance Class E Endurance Class D or above 2 * 200 GB SSD Performance Class D or above Endurance Class C or above I/O Controller Queue Depth >=256 Queue Depth >=256 Queue Depth >=512 Queue Depth >=256 NIC 10GbE (Jumbo Frames Enabled) 10GbE (Jumbo Frames Enabled) 10GbE 10GbE
  32. 32. Magnetic Disks (HDD) • SAS/NL-SAS/SATA HDDs supported – 7200 RPM for capacity – 10000 RPM for performance – 15000 RPM for additional performance • NL SAS will provide higher HDD controller queue depth at same drive rotational speed and similar price point – NL SAS recommended if choosing between SATAand NL SAS • Differentiate performance between clusters with SSD selection, and SSD:HDD ratio. Rule of thumb guideline is 10% of anticipated capacity usage 32
  33. 33. Storage Controllers • SAS/SATA Storage Controllers – Pass-through or “RAID0” mode supported – Pass through recommended for simplicity and performance • Performance using RAID0 mode is controller dependent – Check with your vendor for SSD performance behind a RAID-controller • Storage Controller Queue Depth matters – Higher storage controller queue depth will increase performance – Greater than 256 Queue depth recommended for all but entry level solution profiles • Validate number of drives supported for each controller 33
  34. 34. Storage Controllers – RAID0 Mode • Configure all disks in RAID0 mode – Flash based devices (SSD) – Magnetic disks (HDD) • Disable the storage controller cache – Allows better performance as cache is controlled by Virtual SAN • Disks Device cache support – Flash based devices leverage write through caching – • ESXi may not be able to differentiate flash based devices from magnetic devices. – Use ESXCLI to manually flag the devices as SSD 34
  35. 35. Network • 1Gb / 10Gb supported for hybrid – 10Gb shared with NIOC for QoS will support – If 1GB then recommend dedicated links for Virtual SAN • 10Gb required forAll Flash • Jumbo Frames will provide nominal performance increase – Enable for greenfield deployments • Consider NIC teaming for availability/redundancy • Multicast must be configured and functional between all hosts • Virtual SAN supports both VSS & VDS – NIOC requires VDS – most environments • Network bandwidth performance has more impact on host evacuation, rebuild times than on workload performance 35
  36. 36. Firewalls • Virtual SAN Vendor Provider (VSANVP) – Inbound and outbound - TCP 8080 • Cluster Monitoring, Membership, and Monitoring Services (CMMDS) – Inbound and outbound UDP 12345 - 23451 • Reliable Datagram Transport (RDT) – Inbound and outbound TCP 2233 36
  37. 37. Virtual SAN Sizing & TCO Rafael Kabesa – kabesar@vmware.com @rafikabesa
  38. 38. Sizing & TCO for Virtual SAN?
  39. 39. Why should you care? 1. You want to bring value add to your customers 2. You don’t want to over or under size 3.You want your customer to understand why • Sizing Recommendation • VSAN Value 38
  40. 40. Sizing & TCO Made Easy VSANTCO.VMware.com Or at least easier..
  41. 41. Sizing Inputs Screen 41
  42. 42. Step 1 – VM Profiling What do you want to run on Virtual SAN? 1 2 3 4 5 42
  43. 43. Multiple Profiles? 43
  44. 44. Aggregated Results 44
  45. 45. What about the Hardware? 45
  46. 46. Step 2 – Pick Your Hardware 46 CONFIDENTIAL
  47. 47. Select Performance Profile 1 47
  48. 48. Hardware Quick Reference Guide www.vmware.com/go/virtualsan-hcl 48
  49. 49. Tweak the Configuration to Your Needs 2 49
  50. 50. Advanced - Customize HDDs & SSDs Types and Prices 50
  51. 51. Optimize HDDs & SSDs Numbers 3 51
  52. 52. Check Cache Ratio & #Nodes 4 5 52
  53. 53. Step 3 – Review Your Sizing Results 53 CONFIDENTIAL
  54. 54. Summary Tables 54
  55. 55. Step 4 – TCO Inputs 55 CONFIDENTIAL
  56. 56. Pick the Appropriate License 56
  57. 57. Choose Alternative Solution to Compare To 57
  58. 58. Advanced – Customize the Alternative Solution 58
  59. 59. Advanced – Edit Networking Costs 59
  60. 60. Step 5 – OPEX Assumptions 60 CONFIDENTIAL
  61. 61. Edit Labor Savings Estimates 61
  62. 62. Edit Power & Cooling Savings 62
  63. 63. Define TCO Time Frame 63
  64. 64. Step 6 – Review TCO Results 64 CONFIDENTIAL
  65. 65. TCO Results – Graphical Representation 65
  66. 66. TCO Results – Graphical Representation 66
  67. 67. TCO Results – Graphical Representation 67
  68. 68. Feedback? Questions? Rafael Kabesa – kabesar@vmware.com https://vsantco.vmware.com 68
  69. 69. Virtual SAN All Flash Reference Architecture Powered by
  70. 70. OLTP Results Summary All Flash Virtual SAN™ (VSAN) February 5, 2015 © 2014 SanDisk Corporation | 70 Biswapati Bhattacharjee
  71. 71. OLTP Solution with All-Flash Virtual SAN 6.0 Server Platform  4 Node of Dell R730 G13 series servers  2 Disk Groups per node (1 SAS + 3 SATA each DG)  Caching: SanDisk Lightning Ascend Gen II 12G SAS Drive (400 GB)  Capacity: SanDisk CloudSpeed SATA Drive (960 GB)  Disk Controller: Dell PERC H730P Controller VM Configuration  8 vCPU and 30 GB RAM  4 VM – each node running 1 VM and 1 database instance  ~ 600 GB disk file for each VM, Oracle SGA16GB Software  VSAN 6.0, ESXi 6.0, Oracle 12c,TPHMa=mTrmanesarcDtioBn P–erOSLecToPnd, RHEL 7.0 2 Million TPMs on VSAN 6.0 DG 1 DG 1 DG 1 DG 1 DG 1 DG 1 DG 1 DG 1 Node 1 Node 2 Node 3 Node 4 4-Node VSAN Cluster for OLTP Workload DG 1 DG 2 Virtual SAN 6.0 Node 1 Node 2 Node 3 Node 4 DG 1 DG 2 DG 1 DG 2 DG 1 DG 2 Oracle Instance 1 Oracle Instance 2 Oracle Instance 3 Oracle Instance February 5, 2015 © 2014 SanDisk Corporation | 71 4
  72. 72. HammerDB Steady State TPM February 5, 2015 © 2014 SanDisk Corporation | 72 VM 01 VM 12 VM 03 VM 04 VM Name Avg. TPM VM 01 517189 VM 02 530608 VM 03 509138 VM 04 531184 Total Avg. TPM (HammerDB ) 2088119
  73. 73. Oracle DB Memory (SGA) Setting February 5, 2015 © 2014 SanDisk Corporation | 73 SGA = 16G cache=12G * This is not an IOPS test and this box can drive more IOPS with ample CPU cycle available to it VM Name HammerDB TPM HammerDB NOPM IOPS* VM 01 517189 54009 6330.88 VM 02 530608 47716 6919.96 VM 03 509138 51152 7129.40 VM 04 531184 47013 6952.98 Total TPM 2088119
  74. 74. Oracle DB Memory (SGA) Setting February 5, 2015 © 2014 SanDisk Corporation | 74 SGA = 2G cache=1G VM Name HammerDB TPM HammerDB NOPM IOPS VM 01 460608 24461 15219.66 VM 02 485881 22898 14221.75 VM 03 416861 26012 16487.35 VM 04 450486 25439 17154.53 Total TPM 1813836
  75. 75. VSAN Disks Latency – Steady State TPM VM 01 (msec) – 1 hr. Latency Graph February 5, 2015 © 2014 SanDisk Corporation | 75 VM 02 (msec) – 1 hr. Latency Graph VM 03 (msec) – 1 hr. Latency Graph VM 04 (msec) – 1 hr. Latency Graph
  76. 76. Key Takeaways Beginning of All Flash VSAN Journey  Tests were performed using HammerDB with a OLTP workload (e.g. e- commerce applications, order processing/fulfillment (Amazon, E-bay), shopping cart creation etc…)  Out of the box 2 million transaction per minute (TPM)  Consistently sub-millisecond latency during 1 hr. test Way more to go  More TPM can be squeezed out of the box  Test scale out  Test database consolidation February 5, 2015 © 2014 SanDisk Corporation | 76
  77. 77. Please submit your feedback via our mobile app.
  78. 78. 77 Rakesh Radhakrishnan radhakrishnanr@vmware.com THANK YOU Rafael Kabesa kabesar@vmware.com

×