  1. 1. POWER8 Hardware Enhancements and Update July 9, 2014
  2. 2. Student Guide & Workshop & Internal Training & Confidential Update Daily https://goo.gl/VVmVZ0 © 2014 International Business Machines Corporation 2 Competitive Positioning Power vs. Oracle Systems 2 http://ouo.io/DH476 Competitive Positioning Power vs. Oracle Systems 1 http://ouo.io/HpEK0 KVM on Power -- Open Virtualization Choice for Linux http://ouo.io/sSB89 Power Hardware and System Software Announcement Overview http://ouo.io/8rqfXm Power Systems Management - PowerVC http://ouo.io/A0clE POWER8 Hardware Announcements and Enhancements 1 http://ouo.io/Lvy0At POWER8 Hardware Announcements and Enhancements 2 http://ouo.io/m6Zoj9 POWER8 Hardware Deep Dive Technical Presentation http://ouo.io/hyAP3P POWER8 Hardware Enhancements and Update http://ouo.io/M41Xh POWER8 Proof-of-Technology http://ouo.io/mF5Kh Virtualization differences of Power VM, Power KVM and VMware http://ouo.io/KfLNVM Win the Battle Against x86! Arm Yourself with the IBM POWER8 Playbook http://ouo.io/hRoW6
  3. 3. Agenda Power S814 July Announcement Edward Liu POWER8 Processor and I/O Enhancements Mark Olson Corsa and FPGA Overview Robert Sherwood IBM Rackswitches – MTM Transitions Pramodh Mallipatna 3© 2014 International Business Machines Corporation
  4. 4. POWER S814 July Announcement Revolutionizing how IT is created and consumed Edward Liu Offering Manager
  5. 5. 5 Power Systems S822L Power Systems S812L •1-socket, 2U •Up to 12 cores POWER 8 •512 GB memory •6 PCI Gen3 siot •Linux only •Up to One CAPI support •PowerVM or PowerKVM •2-socket, 2U •Up to 24 cores POWER8 •1 TB memory •9 PCI Gen3 slot •Linux only •Up to 2 CAPI support •PowerVM or PowerKVM •2-socket, 2U •Up to 20 cores POWER8 •1 TB memory •9 PCIe Gen 3 •AIX & Linux •Up to 2 CAPI support •PowerVM Power Systems S822 1 & 2 Sockets Power Systems S814 •1-socket, 4U •Up to 8 cores POWER8 •512 GB memory •7 PCIe Gen 3 •AIX, IBM i, Linux •Up to 1 CAPI support •PowerVM Power Systems S824 Power Systems: Innovation to put data to work •2-socket, 4U •Up to 24 cores POWER8 •1 TB memory •11 PCIe Gen 3 •AIX, IBM i, Linux •Up to 1 CAPI support •PowerVM POWER Scale-out Systems - Created for New Workloads & Enhanced Core Values  Provide efficient consolidation of business workloads  Designed for demanding environments where uptime is critical and downtime is costly  Deliver a higher value, more secure, and more reliable platform than competitors • Processor and Memory – Up to 12-core POWER8 processor card – Up to 8 Simultaneous Multi Thread per core – Transactional Memory – Java Code Optimization w/HW Assist • I/O innovation – PCIe Gen3 – Coherent Accelerator Processor Interface • RAS – RAID 0, 5, 6, 10 in the base – Concurrent maintenance PCIe Gen3 slots – Standard redundant power/cooling New 4-core © 2014 International Business Machines Corporation
  6. 6. 6 The New 4-core Power S814 • 1 socket, 4 EIA units with 4, 6 or 8 core processor card, 16- 512GB memory • Standard, split, and high perf RAID backplanes •PowerVM virtualization •AIX, IBM i, RHEL, SUSE OS Highlights • Highly secure and scalable architecture providing a stable database and middleware platform for efficient deployment of business processing and mission critical applications • Ideal for mid-sized business customers consolidating UNIX, IBM i and Linux workloads •The new Power S814 4-core POWER8 processor offering with IBM i P05 pricing tier ( while S814 6-core and 8-core with IBM i P10 pricing tier ), small tier AIX and Linux pricing as roadmap to 4-core Power 720 and address market low cost pricing requirement.  Include IBM i Solution Edition and CBU support  Limited I/O support  no feature code I/O drawers like #5887 and no future PCIe expansion drawer. (Fibre Channel attached drawers/SANs supported.)  Max of 8 (June) or 10 (July) storage bays  Support only HHD 139G & 283G and SSD 387G drives (#ELDT and #ELDU available at July 25th) Open Technology Server for mid-sized business solutions © 2014 International Business Machines Corporation
  7. 7. 7 POWER 720 and Power S814 Power 720 Power S814 Processor Offerings POWER 7 4-core 3.6 GHz 6-core 3.6 GHz 8 core 3.6 GHz POWER8 4-core and 6-core 3.02 GHz 8-core 3.72 GHz ( Rack only) Memory Features 8 / 16 / 32 / 64GB DDR2 8 to 512GB 4-core (16GB DDR3 max 64GB ) 6-or 8-core (16 / 32 / 64GB DDR3) 16 to 512GB OS Support AIX V7.1, V6.1 IBM i 6.1. 7.1, 7.2 Linux RHEL 6.4, SLES 11 SP2 AIX V7.1, V6.1 IBM i 7.1, 7.2 Linux RHEL 6.5, 7 SLES 11 HDD/SSD Bays in system unit HDD/SSD Bays in system unit Standard 6SFF or 8 SFF 4-core: 8SFF 6 -or 8-core :Standard: 12 SFF or 18 SFF PCIe Slots (low profile) Ten Gen2 slots: Five x8, One x4 and 4 LP x8* Np Hot swap No CAPI capable Seven Gen3 slots: Two x16 and Five x8 (one x8 PCIe slot must contain a 4-port 1Gb Ethernet LAN) Hot swap CAPI capable – max 1 Integrated SAS Controller Standard: JBOD, RAID 0,1,10 Optional: 175MB cache & RAID 5 & 6 Standard JBOD, RAID 0,5,6,10 Optional: 7200MB# cache & Easy Tier function Ethernet Adapter In one PCIe Slot Quad 10/100/1000 Quad 10/100/1000 PCIe I/O Drawers Max 2 PCIe Gen1 Drawers n/a (SOD Gen3) Storage Drawer Max 14 EXP24S 6-or 8-core only: Max 24 EXP24S Electrical Power Tower : 100 to 127AV or 200V to 240V AC Rack 200V to 240V AC Tower : 100 to 127V AC or 200V to 240V AC Rack 200V to 240V AC Redundant Power and Cooling Optional Standard EnergyScale Active Thermal Power Management Dynamic Energy Save & Capping Warranty 3 Years # 1.8GB write cache with compression up to 7.2 GB effective * 4 LP slots required optional PCIe raiser card which takes a GX++ slot • Highly secure and scalable architecture providing a stable database and middleware platform for efficient deployment of business processing and mission critical applications • Ideal for mid-sized business customers consolidating UNIX, IBM i and Linux workloads © 2014 International Business Machines Corporation
  8. 8. 8 S814 list price summary * Due to the memory module limitation of 4-core configuration, 2x16GB RAM price is higher than 32GB © 2014 International Business Machines Corporation +20% +39%
  9. 9. POWER8 Processor and I/O Enhancements Mark Olson Power Systems WW Product Management
  10. 10. 10© 2014 International Business Machines Corporation 4-core S814
  11. 11. 12© 2014 International Business Machines Corporation 4-core 1S4U Scale-out System (June) Power S814  Form Factor: 4U or Tower  Single Socket  Cores: 4 (3.0 GHz)  Memory: Up to 64 GB  Slots: 7 PCIe Gen3 Full-high (Hotplug)  Ethernet: 4-port 1 Gbt in PCIe slot  Integrated ports: USB (4/5), Serial (1), HMC (2)  Internal Storage  DVD  8 SFF Bays * -- Split Backplane: 4 + 4  or 8 SFF Bays * with Easy Tier with 7GB write cache  Hypervisor: PowerVM  OS: AIX, IBM i (P05 software tier), Linux 3 Yr Warranty * Physically 12 bays or 18 bays are present, but usage of a max of 8 drives (SSD or HDD or mix) is supported, Note 10 June announcement was for 8 drives and 15 July announcement increased to 10 drives.
  12. 12. 13© 2014 International Business Machines Corporation 4-core 1S4U Scale-out System (July) Power S814  Form Factor: 4U or Tower  Single Socket  Cores: 4 (3.0 GHz)  Memory: Up to 64 GB  Slots: 7 PCIe Gen3 Full-high (Hotplug)  Ethernet: 4-port 1 Gbt or 2-port 10/1 Gbt in PCIe slot  Integrated ports: USB (4/5), Serial (1), HMC (2)  Internal Storage  DVD  10 SFF Bays * -- Split Backplane: 5 + 5  or 10 SFF Bays * with Easy Tier with 7GB write cache  Hypervisor: PowerVM  OS: AIX, IBM i (P05 software tier), Linux 3 Yr Warranty * Physically 12 bays or 18 bays are present, but usage of a max of 10 drives (SSD or HDD or mix) is supported, Note 10 June announcement was for 8 drives and 15 July announcement increased to 10 drives. Also not split back plane can also be split 4+6 as well as 5+5
  13. 13. 14© 2014 International Business Machines Corporation 4-Core Power S814 Four-core server for AIX, IBM i and Linux.  Especially interesting to IBM i clients because of its P05 software tier  3 GHz cores  Like the POWER7 4-core offering – no feature code I/O drawers like #5887 and no future PCIe expansion drawer. (Fibre Channel attached drawers/SANs supported.)  Like the POWER7 4-core – 64GB memory maximum. 4-core POWER8 uses only 16GB memory features  Max of ten SFF-3 drives in system unit (SSD or disk or mix) -- POWER7 4-core maximum is eight. POWER8 4-core is 25% more drives as of July.  Supports 15k 139/146GB and 15k 283/300GB disk drives and supporting 387GB SSD. Not supporting other drive sizes. 4-core S814 offers better price/performance than 4-core 720 and higher function, but the absolute price of S814 4-core option higher than 720 4-core
  14. 14. 16© 2014 International Business Machines Corporation Power 720 Power System S814 Processor POWER7+ POWER8 Sockets 1 1 Cores 4 4 Maximum Memory* 64 GB @ 1066 MHz 64 GB @ 1600 MHz Memory Cache No Yes Memory DRAM Spare No Yes System unit PCIe slots 6 PCIe Gen2 FH Opt 4 PCIe Gen2 LP 7 PCIe Gen3 FH PCIe Hot Plug Support No Yes Ethernet ports in required PCIe adapter 4-port 1 Gbt (in x4 slot) 4-port 1 Gbt (x8 Slot) or 2-port 10/1 Gbt (x8 slot) * SAS bays in system unit 6 or 8 SFF-1 bays 10** SFF-3 bays Integrated write cache Optional 175 MB Optional effectively 7GB Easy Tier Support No (IBM i can use OS integrated capability) Yes (AIX/Linux) IBM i can use OS integrated capability Integrated split backplane* Yes ( 3 + 3 ) But not supported by IBM i Yes ( 5 + 5 ) note zero write cache for SAS controller Bay for SAS tape drive in System unit 1 HH bay No HH bay 4U Scale-out Comparison – 4-core * with latest microcode level in adapter available late August ** Physically more than 10 SAS bays, but a max of 10 drives (July) supported. Could split 4+6 if desired.
  15. 15. 17© 2014 International Business Machines Corporation CPW S824 (1 or 2 socket)  6-core 3.8 GHz 72,000  12-core 3.8 GHz 130,000  8-core 4.1 GHz 94,500  16-core 4.1 GHz 173,500  12-core 1-socket not offered  24-core 3.5 GHz 230,500 S814 (1 socket)  4-core 3.0 GHz 39,500  6-core 3.0 GHz 59,500  8-core 3.7 GHz 85,500 740 POWER7+ (1 or 2 socket)  6-core 4.2 GHz 49,000  12-core 4.2 GHz 91,700  8-core 3.6 GHz 56,300  16-core 3.6 GHz 106,500  8-core 4.2 GHz 64,500  16-core 4.2 GHz 120,000 720 POWER7+ (1 socket)  4-core 3.6 GHz 28,400  6-core 3.6 GHz 42,400  8-core 3.6 GHz 56,300 +40%
  16. 16. 18© 2014 International Business Machines Corporation rPerf (with SMT8) S824 (1 or 2 socket)  6-core 3.8 GHz 120.8  12-core 3.8 GHz 235.6  8-core 4.1 GHz 166.0  16-core 4.1 GHz 323.6  12-core 1-socket not offered  24-core 3.5 GHz 421.8 S814 (1 socket)  4-core 3.0 GHz 66.9  6-core 3.0 GHz 97.5  8-core 3.7 GHz 143.9 S822 (1 or 2 socket)  6-core 3.8 GHz 120.8  12-core 3.8 GHz 235.6  10-core 3.4 GHz 177.8  20-core 3.4 GHz 346.7
  17. 17. 20© 2014 International Business Machines Corporation Processor Activation Features S814 S824 S822 S812L S822L 8286-41A 8286-42A 8284-22A 8247-21L 8247-22L Processor DCM Charge activate No-charge activate #EPXK 4c 3.02 GHz #EPYK #EPZK #EPXE 6c 3.89 GHz #EPYE - #EPX1 6c 3.89 GHz #EPY1 - #ELPD 10c 3.42 GHz -- #ELAD #ELPD 10c 3.42 GHz -- #ELAD Processor DCM Charge activate No-charge activate #EPX0 6c 3.02 GHz #EPY0 #EPZ0 #EPXF 8c 4.15 GHz #EPYF - #EPXD 10c 3.42 GHz #EPYD - #ELP3 12c 3.02 GHz -- #ELA3 #ELP4 12c 3.02 GHz -- #ELA4 Processor DCM Charge activate No-charge activate #EPX6 8c 3.72 GHZ #EPY6 #EPZ6 #EPXH 12c 3.52 GHz #EPYH - 100% of processor cores are activated. No-charge activations used with IBM i solution editions or with Linux-only models #2319 factory deconfiguration is supported. New 10 June
  18. 18. 21© 2014 International Business Machines Corporation IBM i Solution Editions Prices are USA suggested list prices and are subject to change without notice. Reseller prices may vary. #4927 For qualified sales of new servers with participating ISVs Minimum size deal required Registration/Approval of deal required prior to installation 6-core or 8-core Power 8S14 • 5 no charge processor core activations • IBM i users @ only $70 • 1 IBM Service voucher • Unlimited users for IBM i Access Family • Reduced price development tools #4928 4-core Power 8S14 • 3 no charge processor core activations • IBM i users @ only $70 • 1 IBM Service voucher • Unlimited users for IBM i Access Family • Reduced price development tools New 10 June Same as for POWER7+
  19. 19. 22© 2014 International Business Machines Corporation CBU for i -- Power S814 Offering for IBM i HA/DR environments Prerequisites New server order Primary server must be a POWER7 720, 740, 750 or POWER8 S814, S824 with equal or higher IBM i software tier. Must purchase minimum of one IBM i processor license entitlement for new CBU server Registration of primary system and CBU is required prior to CBU order being manufactured #0444 Primary for 6/8-core (P10) = Power 720, 740, 750, S824 or S814 (a P10 or P20) ----------------------------------------- Primary for 4-core (P05) = Power 720, S814 ( a P05 or P10 ) IBM i processor license entitlement IBM i user entitlements Offering Advantages Temporary transfer of unused IBM i processor license entitlement from primary to CBU server Temporary transfer of unused IBM i user license entitlements Note: no lower-priced hardware or lower priced IBM i licensing – savings is in transferability. Can not transfer user entitlements from primary servers which have no user entitlements. Temporary transfers CBU Power S814 See S814 sales manual for more details New 10 June Same as for POWER7+ except no POWER6 as primary
  20. 20. 23© 2014 International Business Machines Corporation Memory Card for 4-core Power S814 Card capacity: 16 GB … feature code #EM8B (no other memory features supported on 4-core) Up to 4 Cards --- Max 64GB 1600 MHz Memory Sparing - RAS improvement vs POWER7+ Plugs into backplane (no riser card) 4-core usage announced 10 June
  21. 21. 24© 2014 International Business Machines Corporation 4-core S814 Storage Backplanes Op-panel DVD Backplanes provide  High performance integrated SAS controller(s) built on IBM industry leading PCIe Gen3 SAS adapter technology  All include RAID 0, 1, 5, 6, 10. Plus hot spare capability  Split backplane option with zero-write cache controllers Make sure performance ok without write cache  Easy Tier® function* (AIX/Linux)  10** SAS bays for 2.5-inch (SFF) HDD or SSD  One DVD bay * With dual IOA, expanded function backplane with write cache for AIX/LInux ** Physically more SAS bays are present, but only 10 bays are supported 4-core announced 10 June with full set of backplane features
  22. 22. 25© 2014 International Business Machines Corporation Availability plan: - eConfig 15 July - GA Sept 4-core S814: 4U Storage Backplane Options Must select one  10* SFF SAS bays 1 SAS controller No write cache RAID-0,1,5,6,10 DVD bay 10* SFF SAS bays Dual SAS controllers 7.2**GB cache RAID-0,1,5,6,10 DVD bay Easy Tier function Base Expanded Function * 5+5* SFF SAS bays 2 SAS controllers No write cache RAID-0,1,5,6,10 DVD bay Split * Physically more than 10 SAS bays are present, but use of max of 10 are supported. Also note the split backplane could be split 6+4 in addition to 5+5. ** 1.8GB physical write cache provides up to 7.2GB effectively with compression 4U server Staged availability 4-core announced 10 June
  23. 23. 26© 2014 International Business Machines Corporation S814 / S824
  24. 24. 27© 2014 International Business Machines Corporation PCIe Slots & Expanded Function Backplane for 4U 4U 1S 4U 2S 4U Total PCIe slots (all hot swap) 7 11 Required* LAN adapter (available for client use) 1 1 PCIe slots after required* LAN adapter 6 10 However if use high performance, expanded function backplane AND DECIDE NOT TO USE #EJ0Z 6 without EJ0Z 10 without EJ0Z PCIe slots after required* LAN and if using high performance backplane 5 with EJ0Z 9 with EJ0Z • PCIe slots are all Gen3 slots • 4U are all full high • There is no PCI expansion drawer announced. There is an SOD. * required for IBM Manufacturing July 2014 news: optional #EJ0Z
  25. 25. 29© 2014 International Business Machines Corporation General Scale-out server info
  26. 26. 30© 2014 International Business Machines Corporation Additional Scale-out Server AIX Support On August 29, 2014, AIX 7.1 Technology Level (TL) 1 Service Pack (SP) 10, or later, AIX 7.1 TL 2 SP 5, or later, AIX 6.1 TL 7 SP 10, or later, and AIX 6.1 TL 8 SP 5, or later, will extend support for the following IBM Power Systems:  IBM Power System S822 Server (8284-22A)  IBM Power System S814 Server (8286-41A)  IBM Power System S824 Server (8286-42A)
  27. 27. 31© 2014 International Business Machines Corporation Additional Scale-out Server VIOS Support On August 29, 2014, VIOS 2.2.2.5, or later, and VIOS 2.2.1.9, or later will extend support for the following IBM Power Systems: IBM Power System S822 Server (8284-22A) IBM Power System S814 Server (8286-41A) IBM Power System S824 Server (8286-42A) IBM Power System S812L Server (8247-21L) IBM Power System S822L Server (8247-22L)
  28. 28. 32© 2014 International Business Machines Corporation SOD for PCIe3 Expansion Drawers The following information is not publically announced and is shared only for sales planning purposes. If sharing with clients, it needs to be under non-disclosure  PCIe drawer for Scale-out server attachment is not planned for 2014 announce  A drawer will connect to server using two x16 PCIe slots Note this future drawer is for PCIe slots. The POWER8 servers already have support for the EXP24S disk/SSD only drawer. Unannounced and subject to change Repeating information shared in April – no change
  29. 29. 33© 2014 International Business Machines Corporation Dual port 10GBase-T RJ45 ports - Ethernet NIC traffic Ports default to auto negotiate the highest speed: 10Gb (10GBaseT), 1Gb (1000BaseT) or 100Mb (100BaseT) full duplex. Port's configuration are independent of the one other, but both ports owned by one partitions or one VIOS CAT-6A cabling supported NIM/Linux Install support announced July 2014 (planned GA 29 Aug) PCIe2 2-port 10/1GbE BaseT RJ45 Adapter Supported on POWER8 Systems Operating System support: AIX 6.1 & AIX 7.1 or later IBM i via VIOS Linux RHEL 6 or later SLES 11 or later PowerKVM Host VIOS #EN0W (FH) / #EN0X (LP) CCIN 2CC4 Only $950 Plus inexpensive cabling Prices are USA list prices and are subject to change. Reseller prices may vary.
  30. 30. 34© 2014 International Business Machines Corporation PCIe2 4-Port (10Gb+1GbE) Copper SFP+RJ45 Adapter #EN0V (FH) / #EN0U (LP) CCIN 2CC3 Supported on POWER8 Systems Operating System support: AIX 6.1 & AIX 7.1 or later IBM i via VIOS Linux RHEL 6 or later SLES 11 or later PowerKVM Host VIOS Quad ports: Two 10GbE Copper SFP+ optical Plus Two 1GbE RJ45 Ethernet NIC traffic 10Gb Copper SFP+ ports does not include transceiver – transceivers provided with active twinax cables for up to 5m cable distance (Cables = #EN01, #EN02, #EN03) RJ45 are 1Gb or 100Mb and use CAT-5 or CAT-6A UTP cabling Port's configuration are independent of the one other, but all four ports owned by one partitions or one VIOS CAT-6A cabling supported NIM/Linux install support announced July 2014 (planned GA 29 Aug) Only $1200 Prices are USA list prices and are subject to change. Reseller prices may vary.
  31. 31. 35© 2014 International Business Machines Corporation PCIe2 4-Port (10Gb+1GbE) SR+RJ45 Adapter #EN0S (FH) / #EN0T (LP) CCIN 2CC3 Supported on POWER8 Systems Operating System support: AIX 6.1 & AIX 7.1 or later IBM i via VIOS Linux RHEL 6 or later SLES 11 or later PowerKVM Host VIOS Quad ports: Two 10GbE SR optical Plus Two 1GbE RJ45 Ethernet NIC traffic 10Gb SR ports include optical transceiver for up to 100m cable distance RJ45 are 1Gb or 100Mb and use CAT-5 or CAT-6A UTP cabling Port's configuration are independent of the one other, but all four ports owned by one partitions or one VIOS CAT-6A cabling supported NIM/Linux Install support announced July 2014 (planned GA 29 Aug) Only $1600 Prices are USA list prices and are subject to change. Reseller prices may vary. SR transceivers not shown in picture, but would be included in shipment
  32. 32. 36© 2014 International Business Machines Corporation AIX NIM and Linux Network Install Support 29 August Lack of current function fixed with microcode change to the three adapters:  PCIe2 2-port 10/1GbE BaseT RJ45 Adapter  PCIe2 4-Port (10Gb+1GbE) Copper SFP+RJ45 Adapter  PCIe2 4-Port (10Gb+1GbE) SR+RJ45 Adapter Fix planned to be available 29 August 2014 Newly shipped above adapters will have the fix loaded on the adapter by that time (end August). Already shipped adapters will need to have the clients download the fix from IBM and apply to the adapter to gain the function For PCIe2 4-Port (10Gb+1GbE) SR+RJ45 Adapter (#EN0S, #EN0T) and PCIe2 4-Port (10Gb+1GbE) SFP+ Copper+RJ45 Adapter (#EN0U, #EN0V) the latest level of adapter microcode, level 20100130, or later, is required. For PCIe2 LP 2-port 10/1GbE BaseT RJ45 Adapter (#EN0W, #EN0X, and #EL3Z) the latest level of adapter microcode, level 30080130, or later is required. For download: http://www-933.ibm.com/eserver/support/fixes/fixcentral
  33. 33. 37© 2014 International Business Machines Corporation Additional Config Option for “base” Ethernet For Scale-out servers: Before July annc: Must include a 4-port 1Gb Ethernet Adapter (#5899 or #5260) After July annc with 29 Aug 29 ship dates  For AIX/Linux/VIOS: Must include either one 4-port 1Gb Ethernet adapter (#5899/5260) or one 2-port 10/1Gb Ethernet adapter (#EN0W, #EN0X, #EL3Z)  For IBM i: no change, must include a 4-port 1Gb Ethernet Adapter (#5899 or #5260) (#EN0W IBM i support through VIOS, can not be LAN console) 4-port 1Gb 2-port 10/1Gb Feat code #5899, 5260 #EN0W, EN0X, EL3Z NIC 1Gb 10GBase-T speed 1Gb or 100Mb or 10Mb 10Gb or 1Gb or 100Mb NIM, Linux install Yes Yes * ports RJ45 RJ45 cabling CAT5/6 CAT6A List price on S814/S822 $315 $950 USA list prices. Subject to change without notice. Reseller prices may vary. * with latest fixes planned 29 August
  34. 34. 38© 2014 International Business Machines Corporation #5289/5290 2-port Async Adapter Update  The above adapter was announced as supported in the April 2014 announcement. However in mid May, testing found a problem which requires the adapter to not be supported on POWER8 servers. (The problem is an adapter problem, but the problem fortunately does not occur when used in the POWER6/7/7+ servers or their I/O drawers.)  As a result we will not be shipping any POWER8 servers which have a #5289/5290 adapter in their configuration and we will be removing #5289/#5290 from the POWER8 product structure. eConfig will be updated as soon as possible, but as of today still shows these adapters as valid options.  If you have a POWER8 proposal which uses one of these adapters, you should re-run the configuration without the adapter. No change is required for POWER6/7/7+ servers.  We are working to replace #5289/5290 with a future similar product, but it’s not ready to announce as of June.  Interim to that future product, if you need async ports:  For AIX/LInux ... The 4-port Async card #5785/#5277 is was announced/supported on the POWER8 on 10 June.  For IBM i ... The #2893/2894 communications adapter was always supported, but was made orderable for the POWER8 server on 10 June. If IBM i 7.2, consider a WAN over LAN option. As of 13 June July announce: #EN27/#EN28 2-port Async Adapter announced Equivalent to #5289/5290 – same function, same everything (except is supported on POWER8 servers) #EN27/EN28 support not announced on POWER7/POWER7+ servers. Continue to use #5289/5290 on POWER7+ servers
  35. 35. 39© 2014 International Business Machines Corporation CNA = Converged Network Adapter  Fibre Channel over Ethernet (FCoE) and NIC traffic simultaneously  NIC = Network Interface Card  “Like 3 cards in one” …  A 2-port 10Gb Ethernet NIC card  A 2-port 8Gb Fibre Channel Card  A 2-port 1Gb Ethernet NIC card  Save by buying one card vs 2 or 3 cards – lower price  Save up 2 PCIe slots … 66% reduction !!! 4-port 10GbE CNA (NIC/FCoE) & 1GbE Adapter #EN0M – full high #EN0N – low profile 2 ports 10GbE CNA 2 ports 1GbE NIC only For POWER8 Scale-out server 10Gb optical Fibre LR ports New 15 July 2014 Long Range optical fibre Very similar to #EN0H/EN0J/EL3B – optical SR #EN0K/EN0L/EL3C – copper twinax LR = long range optical fiber Up to 10 km (NIC) Not announced on POWER7+ servers Max 300m if using FCoE Transceiver included in #EN0M/EN0N
  36. 36. 40© 2014 International Business Machines Corporation POWER8 PCIe Adapters Adds: June 2014 June Additions Communications 2-port Async/Bisync (IBM i) #2893, #2894 Add orderable Communications 4-port Async (AIX / Linux) #5277, #5785 Add support & order Graphics 3D graphics for RHEL7 #EC42, #EC41 Linux REH7 only
  37. 37. 41© 2014 International Business Machines Corporation POWER8 PCIe Adapters Adds: July 2014 July Additions Ethernet NIC 2-port 1GbE RJ45 #5767, #5281 Ethernet NIC 2-port 1GbE SX optical #5768, #5274 Ethernet NIC 4-port 1Gbe RJ45 #5717, #5271 Ethernet NIC 1-port 10GbE SR optical #5769, #5275 Ethernet NIC & FCoE 2-port 10GbE SR optical #5708, #5270 Ethernet NIC & FCoE 4-port 10GbE+1GbE Copper Twinax+RJ45 #EN0K, #EN0L, #EL3C Ethernet NIC & FCoE 4-port 10GbE+1GbE LR+RJ45 #EN0M, #EN0N NEW adapter Ethernet NIC & RoCE 2-port 10GbE Copper twinax #EC28, #EC27, #EL27 Fibre Channel 2-port 4Gb #5774, #5276, #EL09 SAS RAID 2-port 380MB cache PCIe1 HDD/SSD #5805 Add support only SAS RAID 3-port large cache PCIe2 HDD/SSD #5913 Add support only SAS RAID 3-port large cache PCIe2 HDD/SSD #ESA3 Add support only Communications 2-port Async (AIX / IBM i / Linux ) #EN27, #EN28 NEW Replace 5289/5290
  38. 38. 42© 2014 International Business Machines Corporation POWER8 PCIe Adapters Adds: June/July 2014 June Additions Communications 2-port Async/Bisync (IBM i) #2893, #2894 Add orderable Communications 4-port Async (AIX / Linux) #5277, #5785 Add support & order Graphics 3D graphics for RHEL7 #EC42, #EC41 Linux REH7 only July Additions Ethernet NIC 2-port 1GbE RJ45 #5767, #5281 Ethernet NIC 2-port 1GbE SX optical #5768, #5274 Ethernet NIC 4-port 1Gbe RJ45 #5717, #5271 Ethernet NIC 1-port 10GbE SR optical #5769, #5275 Ethernet NIC & FCoE 2-port 10GbE SR optical #5708, #5270 Ethernet NIC & FCoE 4-port 10GbE+1GbE Copper Twinax+RJ45 #EN0K, #EN0L, #EL3C Ethernet NIC & FCoE 4-port 10GbE+1GbE LR+RJ45 #EN0M, #EN0N NEW adapter Ethernet NIC & RoCE 2-port 10GbE Copper twinax #EC28, #EC27, #EL27 Fibre Channel 2-port 4Gb #5774, #5276, #EL09 SAS RAID 2-port 380MB cache PCIe1 HDD/SSD #5805 Add support only SAS RAID 3-port large cache PCIe2 HDD/SSD #5913 Add support only SAS RAID 3-port large cache PCIe2 HDD/SSD #ESA3 Add support only Communications 2-port Async (AIX / IBM i / Linux ) #EN27, #EN28 NEW Replace 5289/5290
  39. 39. 43© 2014 International Business Machines Corporation POWER8 PCIe Adapters as of July (page 1) Ethernet NIC 4-port 1GbE RJ45 #5899, #5260 Ethernet NIC 2-port 10GbE 10GBase-T RJ45 #EN0W, #EN0X, #EL3Z Ethernet NIC & FCoE (CNA) 4-port 10GbE+1GbE SR+RJ45 #EN0H, #EN0J, #EL3B Ethernet NIC 4-port 10GbE+1GbE SR optical #EN0S, #EN0T Ethernet NIC 4-port 10GbE+1GbE Copper twinax #EN0U, #EN0V Ethernet NIC & RoCE 2-port 10GbE SR optical #EC29, #EC30, #EL2Z Ethernet NIC 2-port 10GbE SR optical iSCSI TOE #5744, #5280 Ethernet NIC 2-port 10GbE SR optical #5284, #5287, #EL2P Ethernet NIC 1-port 10GbE LR optical (IBM i native) #5772 Ethernet NIC & OpenOnload 2-port 10GbE Copper twinax #EL39, #EC2J, #EC2G Ethernet NIC & RoCE 2-port 40GbE QSFP+ #EC3A, #EC3B Ethernet NIC 2-port 1GbE RJ45 #5767, #5281 Ethernet NIC 2-port 1GbE SX optical #5768, #5274 Ethernet NIC 4-port 1Gbe RJ45 #5717, #5271 Ethernet NIC 1-port 10GbE SR optical #5769, #5275 Ethernet NIC & FCoE 2-port 10GbE SR optical #5708, #5270 Ethernet NIC & FCoE 4-port 10GbE+1GbE Copper Twinax+RJ45 #EN0K, #EN0L, #EL3C Ethernet NIC & FCoE 4-port 10GbE+1GbE LR+RJ45 #EN0M, #EN0N Ethernet NIC & RoCE 2-port 10GbE Copper twinax #EC28, #EC27, #EL27 w/ NIM w/ NIM w/ NIM * Late change to drop. See details in following chart Jul
  40. 40. 44© 2014 International Business Machines Corporation POWER8 PCIe Adapters as of July (page 2) Fibre Channel 2-port 8Gb #5735, #5273, #EL2N Fibre Channel 4-port 8Gb (FH) #5729 Fibre Channel 4-port 8Gb (LP) #EN0Y Fibre Channel 2-port 16Gb #EN0A, #EN0B Fibre Channel 2-port 4Gb #5774, #5276, #EL09 Communications 1-port Bisync (IBM i) #EN13, #EN14 Communications 2-port Async/Bisync (IBM i) #2893, #2894 Communications 4-port Async (AIX / Linux) #5277, #5785 Communications 2-port Async RS232 5289/5290 replace #EN27, #EN28 SAS RAID 4-port no-cache PCIe3 for SSD/HDD #EJ0J, #EJ0M, #EL3B SAS Tape/DVD 4-port tape/DVD PCIe3 #EJ10, #EJ11, #EL60 SAS RAID 4-port huge-cache PCIe3 for SSD/HDD #EJ0L SAS RAID/Tape/DVD 2-port no-cache PCIe1 for HDD #5901, #5278, #EL10 SAS RAID 2-port 380MB cache PCIe1 HDD/SSD #5805 SAS RAID 3-port large cache PCIe2 HDD/SSD #5913 SAS RAID 3-port large cache PCIe2 HDD/SSD #ESA3 Jun Jul Jul Jul
  41. 41. 45© 2014 International Business Machines Corporation POWER8 PCIe Adapters as of July (page 3) Infiniband (IB) 2-port QDR IB SR optical #5285, #5283 Graphics 2D graphics for general use #5748, #5269 Graphics 3D graphics for RHEL7 #EC42, #EC41 Encryption Crypto Coprocessor 4765-001 #4807 USB 4-port USB-3 #EC45, #EC46 Programmable FPGA PCIe3 FPGA Accelerator #EJ12, #EJ13 Jun
  42. 42. 46© 2014 International Business Machines Corporation PCIe Adapters NOT Supported: July 2014 Ethernet NIC 2-port 10GbE copper twinax #5288, #5286 old Ethernet NIC 1-port 10GbE CX4 #5732, #5272 Old Ethernet NIC 4-port 10GbE+1GbE Copper twinax+ RJ45 #5745, #5279 Old Ethernet NIC 2-port 10GbE Copper twinax #EL3A, #EC2K, #EC2H Use OpenOnload Fibre Channel 1-port 4Gb #5773 Old, use 8Gb or if must, use 2-port 4Gb Communications 2-port Async RS232 5/2014 add to list #5289, #5290 Use EN27/EN28 SAS RAID 2-port 380MB cache PCIe1 HDD/SSD #5903 Use PCIe3, or use #59805 if you must SAS RAID 2-port zero cache PCIe2 SSD #ESA1, #ESA2, #EL2K Use PCIe3 EJ0J/M USB 4-port USB-2 #2728 Old, use USB-3 SSD on PCIe card 4-slot 1.8-inch SSD on SAS adapter #2053, #2054, 2055 Use controller in storage backplaneFlash on card Flash Adapter 90 #ES09 Much shorter list of “not supported” adapters now
  43. 43. 48© 2014 International Business Machines Corporation Integrated Ports on the System Unit No port feature codes (except 4U SAS ports) 4U 2U USB-3 with full client usage 2 front 2 rear 2 front, 2 rear USB-2 primarily IBM use, limited client use supported*. Ports off Service Processor card 2* rear 2 rear HMC ports - 1Gb Ethernet RJ45 2 rear 2 rear Serial / System port - RJ45 ** 1 rear 1 rear 2 SAS ports with high performance, dual IOA controller storage backplane on 2-socket servers – can attach one EXP24S drawer 2 rear Mandatory #EJ0Z feature. Ports take a PCIe slot 2 rear No feat code. Ports do not take a PCIe slot * For IBM i Unlike POWER7 or POWER6, IBM i communication to UPS is NOT via the serial port on POWER8 server. POWER8 connection to UPS for IBM i is over the USB-2 ports off the service processor card. A converter cable #ECCF should be used to convert USB port to 9-pin D-Shell connector which can be connected to the UPS cable. The cable can be attached after the server is powered up and running. Once the cable is plugged in, the service processor to which the USB-2 ports are attached senses the cable and its integrated cable type ID information and then sets the USB-2 port up for UPS communications. ** For AIX/Linux For attaching serial devices like a Async console which doesn’t have a RJ45 interface. Just like on POWER7/POWER7+, use #3930 converter cable to provide a 9-pin D-Shell connector. Depending on country, #ECCF availability varies
  44. 44. 49© 2014 International Business Machines Corporation ECCF Cable Details Late breaking news in late May 2014. Testing/approvals by different certification organizations around the world for the #ECCF cable didl not support a 10 June 2014 GA. Functionally the cable has been tested and is ready for GA. However, cables have to be approved by different organizations with different standards around the world. We project to have certifications/approvals in place for this cable on the following schedule. 18 June Canada/USA 25 June Australia/Japan 9 July European Union 16 July remainder of the world except Korea/Taiwan 6 Aug Korea/Taiwan The above projections are our current best estimates and are subject to change. The UPS communication does NOT impact the ability of a 9910 UPS to provide power to the server. But the cable allows status information to be provided to the , the server, alerting it to the fact its electrical power is coming from a UPS. Assuming you‘ve set up your server to do so, it can more gracefully shut down if the UPS batteries are running out before regular power sources are restored. This is the only UPS communication mechanism for IBM i. AIX/Linux can alternatively implement an Ethernet-based option where UPS-provided appliction code runs on the server and talks to the UPS. The cable can be attached without booting the server.
  45. 45. 52© 2014 International Business Machines Corporation POWER7+ EXP30 Ultra Drawer
  46. 46. 53© 2014 International Business Machines Corporation SSD Refreshed in EXP30 Ultra Drawer New 1.8-inch SSD feature codes: #ES0J/ES0K and #ESRJ/ESRK New CCIN 59BE Same 387GB capacity as existing SSD features Newer eMLC3 technology, a little faster than eMLC2 SSD (#ES02/ES04) Almost 20% LOWER LIST PRICE than eMLC2 1.8-inch SSD Can intermix eMLC2 and eMLC3 SSD in the same EXP30 drawer (#EDR1 or #5888) and can mix in the same array Differs physically from previous features. New features require a carrier #EB2W to fit into EXP30 bay. Each SSD needs one carrier. Six pack SSD features need six #EB2W. Previous SSD included a carrier already NOT used in POWER8 servers June 10 annc
  47. 47. 54© 2014 International Business Machines Corporation Reminder: the April 30th hardware deepdive pitch on Scale-out servers and other April content has been updated w/ fixes & add’l content. Do you have the “update4” version? Posted on SSI / PartnerWorld  IBMers: http://w3.ibm.com/sales/support/ShowDoc.wss? docid=SGDF097039N48949N97&node=brands,B5000|brands,B5Y00| clientset,IA (http://w3.ibm.com/sales/support/ShowDoc.wss? docid=SGDF097039N48949N97&node=brands,B5000%7Cbrands,B5Y00% 7Cclientset,IA)  IBM Business Partners: http://www.ibm.com/partnerworld/wps/servlet/ContentHandler/SGDF0970 39N48949N97
  48. 48. 55© 2014 International Business Machines Corporation Thanks !
  49. 49. Corsa and FPGA Overview Robert Sherwood Product Offering Manager, IBM
  50. 50. Corsa 5 A7  Altera Stratix V PCIE Gen 3 card  Supports both PCIe I/O & CAPI models  Initial offering with Z gzip use case for JAVA  Dual 10 GB (lower latency internal PHY)  Not currently supported on Power  8 GB DDR3 1600 SDRAM  Full Card Level RAS  Partial Reconfiguration Attributes  FPGA base accelerator card  PCIe gen3 x8, ranges between 25W & 40W depending on application  ~21W for gzip application  Follows Altera Stratix roadmap PCIe base I/O adaptor  JAVA 7.1 gzip acceleration use case  Single root I/O virtualization, 15 virtual functions Future support for Power Server CAPI  Coherent Accelerator Processor Interface OS Support  AIX 7.1 Software/Firmware Support  eFW 8.1 RAS  Evaluation in progress of existing device driver features  This application not reprogammable by customers Energy Efficiency / Power Management  FPGA thermals are use-case dependent Certifications  FCC Class A  Environmental Support TBD (pending compliance test)  Acoustic Category – TBD (pending thermal eval) Corsa PCI-E FPGA JAVA gzip adapter PoC Ready May 2013, general use case Transparent zlib HW acceleration integrated into JAVA 7.1 Driving PCIe Tuleta AIX attach 2Q14 JAVA use case Future RPQ: Driving PCIe Tuleta RHEL 6.6 attach JAVA use case © 2014 International Business Machines Corporation 62
  51. 51. Custom Hardware Application POWER8 CAPP Coherence Bus PSL FPGA or ASIC Customizable Hardware Application Accelerator • Specific system SW, middleware, or user application • Written to durable interface provided by PSL POWER8 PCIe Gen 3 Transport for encapsulated messages Processor Service Layer (PSL) • Present robust, durable interfaces to applications • Offload complexity / content from CAPP Virtual Addressing • Accelerator can work with same memory addresses that the processors use • Pointers de-referenced same as the host application • Removes OS & device driver overhead Hardware Managed Cache Coherence • Enables the accelerator to participate in “Locks” as a normal thread Lowers Latency over IO communication model POWER8 CAPI (Coherent Accelerator Processor Interface) © 2014 International Business Machines Corporation 63
  52. 52. © 2014 International Business Machines Corporation 64 Processor Enablement CAPP PCIe Power Processor CAPI over PCIe Coherently Attached Device  Coherent Attached Processor Proxy (CAPP) in processor – Unit on processor that extends coherency to an attached device – On processor directory responds on behalf of off-chip device (Filtering snoops)  Coherency protocol tunneled over standard PCIe – Eliminates the need for special I/Os and protocol logic • CAPI utilizes standard Posted Write and Non-posted Reads – Reduces the complexity and bandwidth requirements of the attached device  Enables attached device to be a peer to the processor – Simplifies programming model between application – Enables device to use same effective address as application running in processor – Eliminates the cumbersome I/O Device Driver requirements • Pinned memory not required
  53. 53. Coherent Accelerator Processor Interface (CAPI) Overview CAPP PCIe Power Processor FPGA Functionn Function0 Function1 Function2 CAPI IBM Supplied POWER Service Layer Typical I/O Model Flow Flow with a Coherent Model Shared Mem. Notify Accelerator Shared Mem. Notify Accelerator AccelerationAcceleration Shared Memory Completion Shared Memory Completion DD CallDD Call Copy or Pin Source Data Copy or Pin Source Data MMIO Notify Accelerator MMIO Notify Accelerator AccelerationAcceleration Poll / Int Completion Poll / Int Completion Copy or Unpin Result Data Copy or Unpin Result Data Ret. From DD Completion Ret. From DD Completion Advantages of Coherent Attachment Over I/O Attachment  Virtual Addressing & Data Caching – Shared Memory – Lower latency for highly referenced data  Easier, More Natural Programming Model – Traditional thread level programming – Long latency of I/O typically requires restructuring of application  Enables Applications Not Possible on I/O – Pointer chasing, etc… Actual feature(s) Interface logic © 2014 International Business Machines Corporation 65
  54. 54. IBM PowerLinux FPGA Development Kit (RPQ 8A2158) • Provides a platform which allows programmers to develop OpenCL code which targets IBM PowerLinux processors and accelerator cards with Altera FPGAs • Utilizes the Nallatech “Power OpenCL Development Kit” PN: P385-A72-SYSP-01 with an IBM PowerLinux 7R2. • The Nallatech Power OpenCL Development Kit includes - PCIe-385 Card PN: P385-A72-0813P-81 w/CCR (A7 Card) - USB Blaster II (UB2) Development and debug Card PN NT101-0563-03 - Altera Quartus II DKE License - Altera OpenCL SDK - Altera provided Power Linux device driver • The IBM PowerLinux FPGA Development Kit also includes 8 hours of on site IBM Lab Services expertise • The kit requires a separate purchase of an IBM PowerLinux 7R2 server (8246-L2D with 4.2GHz processors) • To order the IBM PowerLinux FPGA Development Kit – Order the PowerLinux 7R2 – Order and Apply RPQ 8A2158 to the PowerLinux 7R2 – Order the Nallatech Power OpenCL Development Kit directly from Nallatech – Call IBM Lab Services to schedule installation and set up. © 2014 International Business Machines Corporation 66
  55. 55. © 2014 International Business Machines Corporation 67
  56. 56. IBM GZIP Acceleration Adapter (EJ13) • Corsa card with GZIP compression/decompression • Useful for customers running workloads which require frequent GZIP compression and decompression such as WebSphere • Customers running JAVA/Util/GZIP will also see significant performance improvements • Feature is particularly effective for workloads requiring transfer of large buffers • Utilizing this adapter can reduce both the storage requirements and congestion in a customer’s environment 68 © 2014 International Business Machines Corporation 68
  57. 57. Field-Programmable Gate Arrays (FPGAs) Hardware-back Java compression APIs Work sent to custom card firmware rather than the CPU. Not only does it run faster on the card, but it frees up the CPU to do other things. Benchmarking Liberty Power Linux shows high performance extensible log (HPEL) engine writes compressed logs as quick as uncompressed© 2014 International Business Machines Corporation 69
  58. 58. © 2014 International Business Machines Corporation Store your Data - Power Data Compression and IBM Java 7R1 ** IDC: The Digital Universe in 2020: Big Data, Bigger Digital Shadows, and Biggest Growth in the Far East With IBM Java 7R1 : Java application to compress files using java.util.zip.GZIPOutputStream class Up to 91% reduction in CPU time using zEDC hardware versus zlib software Up to 74% reduction in Elapsed time (not shown) Compression ratio up-to ~5x Every day over 2000 petabytes of data are created • Between 2005 to 2020, the digital universe will grow by 300x, going from 130 to 40,000 exa-bytes** • 80% of world's data was created in last two years alone (Controlled measurement environment, results may vary) What is it?  zEDC Express is an IO adapter that does high performance industry standard compression  Applications can use zEDC via industry standard APIs (zlib and Java)  Raw throughput up to 1 GB/s per zEDC Express Hardware Adapter HW Exploit of FPGA Compression on POWER 70
  59. 59. IBM Rackswitches MTM Transitions Pramodh Mallipatna Networking Products
  60. 60. 7272 SND Switch OEM-out to Power - MTM Transitions Name MTM Current MTM New IBM RackSwitch G8264 1455-64C 7120-64C IBM RackSwitch G8124E 1455-24E 7120-24E IBM RackSwitch G8052 1455-48E 7120-48E IBM RackSwitch G7028 1455-24L 7120-24L IBM RackSwitch G8264T 1455-48T 7120-48T IBM RackSwitch G8264CS 1455-64F 7120-64F IBM RackSwitch G8316 1611-16E 7120-16E 7 current MTMs will be withdrawn from Power WTAAS; Announced 05/13 with Effective Date 07/31. 7 MTMs will be re-introduced in 2 stages. • Stage 1: 4 MTMs to be re-released. • G8264, G8124W, G8052, G7028 - Announce 08/12; GA 09/01 • Stage 2: 3 MTMs to be re-released • G8264T, G8264CS, G8316 - Announce & GA TBD (GCOIM align). © 2014 International Business Machines Corporation 72
  61. 61. 73 Thank You Merci Grazie Graci as Obrigado Danke Japanese English French Russian German Italian Spanish Brazilian PortugueseArabic Traditional Chinese Simplified Chinese Hindi Tamil Thai Korean © 2014 International Business Machines Corporation

    Be the first to comment

    Login to see the comments

  • h1pan

    Apr. 7, 2016
  • SungYoonMyung

    Aug. 8, 2016
  • bhattu.r

    Mar. 13, 2019

Power8 hardware technical deep dive workshop

Views

Total views

4,701

On Slideshare

0

From embeds

0

Number of embeds

16

Actions

Downloads

211

Shares

0

Comments

0

Likes

3

×