Skip to main content
Performance Evaluation of
Gait Classification
Using Quaternion Waveforms
ID-30
8th International Conference on
Activity and Behavior Computing
Akifumi Sugimoto1, Hirofumi Hori 2,
Hideki Higashioka 3, Mitsunori Matsushita 4
1Faculty of Health Sciences, Aino University, Osaka, Japan
2Faculty of Nursing and Rehabilitation, Konan Women’s University, Hyogo, Japan
3,4Faculty of Informatics, Kansai University, Osaka, Japan
◉ Background
・Gait analysis is important in clinical practice.
・Observational gait analysis is widely used.
→ Reliability and validity can vary.
・Objective measurement is needed.
◉ Problem
・3D motion capture systems are accurate.
→ Expensive and low portability.
・Wearable sensors are more practical.
→ Acceleration alone cannot represent
rotation.
◉ Purpose
・IMU-based gait analysis has progressed.
・Quaternions can represent 3D rotation.
→ Most studies focus on posture or angle
estimation.
Time-series structural analysis is limited.
This study focuses on quaternion waveform structure.
◉ Participants & Gait patterns
・N = 19 healthy adults
(7 M / 12 F, 20 - 22 yrs)
L R
normal Trendelenburg circumduction
Duchenne Duchenne
without
hip abduction
Pattern 1 Pattern 2 Pattern 3 Pattern 4 Pattern 5
with
hip abduction
Gait patterns
Participants
・Normal gait
・4 simulated abnormal gaits
◉ Data Acquisition
・Acceleration (X, Y, Z)
・Quaternion (X, Y, Z, W)
Data Acquisition
Smartphone attachment (pelvis level)
Z
X
Y
◉ Gait Segmentation
Quaternion waveforms → 400-dimensional feature vector
・Segmentation based on Z-axis Acceleration
Right
heel contact
1 gait cycle (R-L-R)
◉ Preprocessing & Dataset
Normalization
Feature Vector
Offset Correction
Resampled to 100 points
( linear interpolation )
400-dimensional vector
( 100 × 4 axes )
Initial value aligned to zero
Dataset
pattern 1 2 3 4 5 total
n 107 142 136 144 155 684
●Structural Analysis
・PCA ・K-means clustering
●Classification
・SVM ( RBF kernel )
●Evaluation
・Accuracy / Macro F-1
◉ Analysis
・5-fold
・Repeated 5×10
・LOSO
・Cross-validation
◉ Results(PCA)
PC1 and PC2 mainly reflected X- and Y-axis rotational structure.
◉ Results( Clustering )
Pattern Cluster 1 Cluster 2 Cluster 3 Cluster 4 Cluster 5
1
98.1 0 0 0 1.9
2
24.6 0 0 0 75.4
3
19.1 6.6 25.7 48.5 0
4
3.5 24.3 22.9 39.4 0
5
7.1 20.0 32.9 39.4 0.7
( % )
Patterns 3–5 showed mixed cluster structures.
Cluster Composition Ratio Across Gait Patterns
Normal
Trendelenburg
Circumduction
Duchenne
Duchenne
without hip abd
with hip abd
◉ Results( SVM )
SVM Classification Performance
Method Accuracy Macro-F1
5-fold CV 0.83 (0.81-0.84) 0.84 (0.82-0.85)
Repeated 5×10 CV 0.83±0.03 0.84±0.03
LOSO 0.74 (0.69-0.78) 0.71 (0.67-0.76)
Values are expressed as percentages (%).
Performance decrease in LOSO suggests inter-subject
waveform variability.
◉ Conclusion
・Structural differences were detected in
quaternion waveforms
・Classification performance was stable
・Generalization across subjects remains
challenging
・Future validation using patient data is required