Skip to main content
B. Pharmacy III Semester
Pharmaceutical Engineering
BP304T
Mr. Ayushmaan Roy
Assistant Professor
Department of Pharmacy
Kalinga University
Naya Raipur (C.G.), India
COURSE OBJECTIVE
Upon completion of the unit student shall be able :
• Different ways to measure the pressure and their machinery instrumentation.
• Study the different materials used in the pharmaceutical plant constructions.
• Emphasize principles, mechanisms and theories of different unit operations.
COURSE OUTCOME
BP304T-PHARMACEUTICAL ENGINEERING 2
• This course is of various unit operations used in pharmaceutical industry designed
to impart a fundamental knowledge on the art and science.
CONTENTS
CLASS NAME- B.Pharmacy
Semester- 3
rd
sem
Paper Code – BP304T
SUBJECT NAME-Pharmaceutical Engineering
S.No. Unit Name /Topic
1
Fluid properties Reynolds experiment , Manometer Orificemeter
2
Rotameter Current flow meter
3
Size reduction Factors principles and applications
4
Apparatus used in size reduction like ball mill, hammer mill
5
Size seperation
Apparatus used in the seperation process
BP304T-PHARMACEUTICAL ENGINEERING 3
CONTENTS
Fluid properties
• Reynolds experiment , Manometer
• Orificemeter
• Venturimeter, Pitot tube
• Rotameter
• Current flow meter
Size reduction
• Factors principles and applications
• Apparatus used in size reduction like ball mill, hammer mill
Size seperation
• Apparatus used in the seperation process
BP304T-PHARMACEUTICAL ENGINEERING 4
REFERENCES/TEXT BOOKS
1. Introduction to chemical engineering – Walter L Badger & Julius
Banchero, Latest edition.
2. Solid phase extraction, Principles, techniques and applications by Nigel
J.K. Simpson- Latest edition.
3. Unit operation of chemical engineering – Mcabe Smith, Latest edition.
4. Pharmaceutical engineering principles and practices – C.V.S
Subrahmanyam et al., Latest edition.
5. Remington practice of pharmacy- Martin, Latest edition.
6. Theory and practice of industrial pharmacy by Lachmann., Latest
edition.
7. Physical pharmaceutics- C.V.S Subrahmanyam et al., Latest edition.
8. Cooper and Gunn’s Tutorial pharmacy, S.J. Carter, Latest edition
BP304T-PHARMACEUTICAL ENGINEERING 5
LECTURE PLAN
Lecture No. Topics to be covered Slide No.
L-1 Flow of fluids: Types of manometers 10-17
L-2
Reynolds number and its significance, Bernoulli’s theorem and its
applications, Energy losses, Orifice meter,
18-30
L-3 manometers 31-55
L-4
·Size Reduction: Objectives, Mechanisms & Laws governing size
reduction, factors affecting size reduction, 56-70
L-5
principles, construction, working, uses, merits and demerits of Hammer
mill, ball mil 71-82
L-6 fluid energy mil 83-96
L-7
Size Separation: Objectives, applications & mechanism of size separation,
official standards of powders, sieves, 97-105
L-8
Principles, construction, working, uses, merits and demerits of Sieve
shake 106-110
9 cyclone separator, Air separator, 111-115
Quiz 20 mcqs with answers 116-126
BP304T-PHARMACEUTICAL ENGINEERING 6
UNIT 1
BP304T-PHARMACEUTICAL ENGINEERING 7
FLUID FLOW
A fluid is a substance that continually deforms (flows) under an applied shear stress.
Fluids are a subset of the phases of matter and include liquids, gases both.
Fluid flow may be defined as the flow of substances that do not permanently resist
distortion.
The subject of fluid flow can be divided into fluid statics and fluid
dynamics.
Identification of type of flow is important in
Manufacture of dosage forms
Handling of drugs for administration
8
BP304T-PHARMACEUTICAL ENGINEERING
FLUID STATICS
 Fluid statics deals with the fluids at rest in equilibrium,
 Behavior of liquid at rest
 Nature of pressure it exerts and the variation of pressure at different layers
Pressure differences between layers of liquids
h1
h2
Point 1
Point 2
9
9
BP304T-PHARMACEUTICAL ENGINEERING
Consider a column of liquid with two openings Which are provided at the
wall of the vessel at different height
The rate of flow through these opening s are different due to the pressure exerted at the
different height
Consider a stationary column the pressure ps is acting on the surface of the fluid, column is
maintained at constant pressure by applying pressure
The force acting below and above the point 1 are evaluated
Substituting the force with pressure x area of cross section in the above equation
Force acting on the liquid
At point 1 =
Force on the surface
+ Force excreted by the liquid
1
0
Above point 1
Pressure at point 1 x Area =
Pressure on the surface x area
+ mass x acceleration
10
BP304T-PHARMACEUTICAL ENGINEERING
11
P1S = PsS + volume x density x acceleration
= PsS + height x area x density x acceleration P1S =
PsS + h1 S ρg
Since surface area is same
P1 = Ps + h1 ρ g
Pressure acting on point 2 may be written as
P2 = Ps + h2 ρ g
Difference in the pressure is obtained by
P2 - P1 = g (Ps + h2 ρ ) – ( Ps + h1 ρ) g
∆P = (Ps + h2 ρ – Ps - h1 ρ ) g
= ∆ h ρ g
11
BP304T-PHARMACEUTICAL ENGINEERING
FLUID DYNAMICS
 Fluid dynamics deals with the study of fluids in motion
 This knowledge is important for liquids, gels, ointments which
will change their flow behavior when exposed to different stress
conditions
MIXING
FLOW THROUGH PIPES
FILLED IN CONTAINER
1
2
12
BP304T-PHARMACEUTICAL ENGINEERING
 The flow of fluid through a closed
channel can be viscous or turbulent and
it can be observed by;
 Reynolds experiment
 Consider Glass tube which is connected
to reservoir of water, rate of flow of
water is adjusted by a valve, a reservoir
of colored solution is connected to one
end of the glass tube with help of nozzle
colored solution is introduced into the
nozzle as fine stream.
1
3
13
BP304T-PHARMACEUTICAL ENGINEERING
1
4
14
BP304T-PHARMACEUTICAL ENGINEERING
1
5
 Laminar flow is one in which the fluid particles move in layers or
laminar with one layer sliding with other.
 There is no exchange of fluid particles from one layer to other.
 When velocity of the water is increased the thread of the colored water disappears and mass of
the water gets uniformly colored, indicates complete mixing of the solution and the flow of the
fluid is called as turbulent flow.
 The velocity at which the fluid changes from laminar flow to turbulent
flow that velocity is called as critical velocity.
15
BP304T-PHARMACEUTICAL ENGINEERING
REYNOLDS NUMBER
In Reynolds experiment the flow conditions are affected by
Diameter of pipe
Average velocity
Density of liquid
Viscosity of the fluid
This four factors are combined in one way as Reynolds number
Reynolds number is obtained by the following equation
D u ρ
η
 Inertial forces are due to mass and the velocity of the fluid particles trying to diffuse the
fluid particles
 viscous force if the frictional force due to the viscosity of the fluid
which make the motion of the fluid in parallel
INERTIAL FORCES
= ------------------------------ =
VISCOUS FORCES
MASS X ACCELERATION OF LIQUID FLOWING
----------------------------------------------------------
SHEAR STRESS X AREA
10
16
BP304T-PHARMACEUTICAL ENGINEERING
17
 If Re < 2000 the flow is said to be laminar
 If Re > 4000 the flow is said to be turbulent
 If Re lies between 2000 to 4000 the flow change between laminar to turbulent
 APPLICATIONS
 Reynolds number is used to predict the nature of the flow
 Stocks law equation is modified to include Reynolds number to study the rate of sedimentation in
suspension
BP304T-PHARMACEUTICAL ENGINEERING
BERNOULLI'S THEOREM
When the principals of the law of conservation energy is applied to the flow of the fluids the
resulting equation is called Bernoulli's theorem
 Consider a pump working under isothermal conditions between points A and B as shown in
figure;
18
BP304T-PHARMACEUTICAL ENGINEERING
19
BP304T-PHARMACEUTICAL ENGINEERING
20
 At point a one kilogram of liquid is assumed to be entering at this
point, pressure energy at joule can be written as
Pressure energy = Pa /g ρA
Where Pa = Pressure at point a
g = Acceleration due to gravity ρA = Density of the
liquid
Potential energy of a body is defined as the energy possessed by
the body by the virtue of its position or configuration
Potential energy = XA
Kinetic energy of a body is defined as the energy possessed by the body by virtue of its
motion,
kinetic energy = UA / 2g 2
Total energy at point A = Pressure energy + Potential energy+ Kinetic
energy
BP304T-PHARMACEUTICAL ENGINEERING
21
Total energy at point A = Pa /g ρA +XA + UA / 2g
2
According to the Bernoulli's theorem the total energy at point A is constant
Total energy at point A = Pa /g ρA +XA + UA / 2g = Constant
2
After the system reaches the steady state, whenever one kilogram of liquid enters at point A,
another one kilogram of liquid leaves at point B
Total energy at point B = PB /g ρB +XB + UB / 2g 2
INPOUT = OUT PUT
Pa /g ρ A +XA + U 2 / 2g =PB /g ρ B +XB + U 2 / 2g
A B
Theoretically all kids of the energies involved in fluid flow should be accounted, pump has
added certain amount of energy
Energy added by the pump = + wJ
BP304T-PHARMACEUTICAL ENGINEERING
22
During the transport some energy is converted to heat due to frictional
Forces
Loss of energy due to friction in the line = FJ
A B
Pa /g ρ A +XA + U 2 / 2g – F + W = PB /g ρ B +XB + U 2 / 2g
• This equation is called as Bernoulli's equation
• Application
 Used in the measurement of rate of fluid flow
 It applied in the working of the centrifugal pump, in this kinetic energy is converted in to
pressure
BP304T-PHARMACEUTICAL ENGINEERING
23
ENERGY LOSS
 According to the law of conversation of energy ,energy balance have to
be properly calculated
 fluids experiences energy losses in several ways while
flowing through pipes, they are
 Frictional losses
 Losses in the fitting
 Enlargement losses
 Contraction losses
BP304T-PHARMACEUTICAL ENGINEERING
24
FRICTIONAL LOSSES
During flow of fluids frictional forces causes a loss in pressure Type of fluid flow also influences
the losses
In general pressure drop will be
PRESSURE DROP αVELOCITY (u)
α Density of fluid(ρ)
α Length of the pipe (L)
α 1 / diameter of the pipe (D)
These relationships are proposed in Fanning equation for calculating friction losses
Fanning equation ∆p = 2fu2Lρ/ D
F = frictional factor
For viscous flow pressure drop Hagen –Poiseullie equation
= 32 Luη / D2
BP304T-PHARMACEUTICAL ENGINEERING
LOSSES IN FITTING
Fanning equation is applicable for the losses in straight pipe When fitting are introduced
into a straight pipe, They cause disturbance in the flow, Which result in the additional loss of
energy
losses in fitting may be due to
Change in direction
Change in the type of fittings
Equivalent length of fitting = Equivalent length x internal diameter
For globe valve = 300 x 50
= 15 meter
That means globe valve is equal to 15 meters straight line, so this length is substituted in
fanning equation
Tee fitting Equivalent
length = 90
Globe valve equivalent length = 300
25
BP304T-PHARMACEUTICAL ENGINEERING
ENLARGEMENT LOSS
If the cross section of the pipe enlarges gradually, the fluid adapts itself to the changed section
with out any disturbance So no loss of energy
If the cross section of the pipe changes suddenly then loss in energy is observed due to eddies
These are greater at this point than straight line pipe
Than u2< u1
For sudden enlargement = ∆ H = (u1 – u2 )2 / 2g
∆ H = loss of head due to sudden enlargement
µ1 µ2
µ1
26
µ2
BP304T-PHARMACEUTICAL ENGINEERING
CONTRACTION LOSSES
If the cross section of the pipe is reduced suddenly the fluid flow is disturbed, the diameter of the
fluid stream is less than the initial value of diameter this point of minimum cross section is known
as vena contracta.
the velocity of fluid at smaller cross section will be greater than at larger cross section, u2> u1
27
BP304T-PHARMACEUTICAL ENGINEERING
28
MANOMETERS
Manometers are the devices used for measuring the pressure difference Different type of
manometers are;
1) Simple manometer
2) Differential manometer
3) Inclined manometer
BP304T-PHARMACEUTICAL ENGINEERING
29
SIMPLE MANOMETER
 This manometer is the most commonly used one
 It consists of a glass U shaped tube filled with a liquid A- of density ρ
Akg /meter cube and
above A the arms are filled with liquid B of density ρ
B .
 The liquid A and B are immiscible and the interference can be seen clearly
 If two different pressures are applied on the two arms the meniscus of
the one liquid will be higher than the other
 Let pressure at point 1 will be P1 Pascal's and point 5 will be P2 Pascal's
 The pressure at point 2 can be written as
= P1+ (m + R ) ρB g
(m + R ) = distance from 3 to 5
BP304T-PHARMACEUTICAL ENGINEERING
P1 P2
m
R
1
30
2
3
4
5
Liquid A
LIQUID
B
BP304T-PHARMACEUTICAL ENGINEERING
31
Since the points 2 and 3 are at same height the pressure at 3 can be written as
Pressure at 3 =P1+ (m + R ) ρB g Pressure at 4 can be
written as
= P2 + gm ρ B
or
= P1+ ρ B ( m + R ) g- ρ a R g
Both the equations should be equal
P2 + gm ρ B = P1+ ρ B ( m + R ) g- ρ a R g
P1 – P2 = gm ρ B - ρ B ( m + R) g + ρ A R g
∆P = gm ρ B - gm ρ B - R ρ B g + R ρ A
=R (ρ A- ρ B )g
BP304T-PHARMACEUTICAL ENGINEERING
32
DIFFERENTIAL MANOMETERS
 These manometers are suitable for measurement of small pressure differences
 It is also known as two – Fluid U- tube manometer
 It contains two immiscible liquids A and B having nearly same densities
 The U tube contains of enlarged chambers on both limbs,
 Using the principle of simple manometer the pressure differences can be written as
∆P =P1 –P2 =R (ρc – ρA) g
BP304T-PHARMACEUTICAL ENGINEERING
33
BP304T-PHARMACEUTICAL ENGINEERING
34
INCLINED TUBE MANOMETERS
Many applications require accurate measurement of low pressure such as drafts and very low
differentials, primarily in air and gas installations
In these applications the manometer is arranged with the indicating tube inclined, as in Figure,
therefore providing an expanded scale
This enables the measurement of small pressure changes with increased
accuracy
P1 –P2 = g R (ρ A - ρ B) sin α
BP304T-PHARMACEUTICAL ENGINEERING
35
BP304T-PHARMACEUTICAL ENGINEERING
36
MEASUREMENT OF RATE OF FLOW OF
FLUIDS
When ever fluid are used in a process it is necessary to measure the rate at which the fluid is
flowing through the pipe,
Methods of measurement are
Direct weighing or measuring
Hydrodynamic methods
Orifice meter
Venturi meter
Pitot meter
Rotameter
Direct displacement meter
BP304T-PHARMACEUTICAL ENGINEERING
37
DIRECT WEIGHING OR MEASURING
The liquid flowing through a pipe is collected for specific period at any point and
weighed or measured, and the rate of flow can be determined.
Gases can not be determined by this method.
ORIFICE METER
Principle:
Orifice meter is a thin plate containing a narrow and sharp aperture
When a fluid stream is allowed to pass through a narrow constriction the velocity of the fluid
increase compared to up stream
This results in decrease in pressure drop and the difference in the
pressure may be read from a manometer
The velocity of the fluid at thin constriction may be written as
U0 =C 0 √ 2g ∆H
BP304T-PHARMACEUTICAL ENGINEERING
38
∆H = difference in height, can be measured by manometer C0 = constant
U0 = velocity of fluid at the point of orifice meter
CONSTRUCTION
 It is consider to be a thin plate containing a sharp aperture through which fluid flows
 Normally it is placed between long straight pipes
 For present discussion plate is introduced into pipe and manometer is connected at points A
and B
WORKING
 Orifice meter is referred as the variable head meter, ie it measure the variation in the pressure
across a fixed construction placed in the path of flow
BP304T-PHARMACEUTICAL ENGINEERING
39
BP304T-PHARMACEUTICAL ENGINEERING
40
 When fluid is allowed to pass through the orifice the velocity of the fluid at point B increase, as a
result at point A pressure will be increased
 Difference in the pressure is measured by manometer
 Bernoulli's equation is applied to point A and point B for experimental conditions
õ0
2 –µ 2 =C √2g ∆H
A 0
µ0 = velocity of fluid at orifice µA = velocity of fluid at
point A C0 = constant
 If the diameter of the orifice is 1/5 or less of the pipe diameter then µA
is neglected so,
Applications
µ0 = C0 √2g ∆H
 Velocity at either of the point A and B can be measured
 Volume of liquid flowing per hour can be determined
BP304T-PHARMACEUTICAL ENGINEERING
41
VENTURI METER
• Principle:
 Venturi meter consist of two tapered sections in the pipe line with
a gradual constriction at its centre.
 When fluid stream is allowed to pass through the narrow throat the
velocity of the fluid increases at the venturi compared to velocity of
the upstream.
 This results in decrease in the pressure head.
 This resulting decrease in the pressure head is measured directly
from the manometer.
BP304T-PHARMACEUTICAL ENGINEERING
42
BP304T-PHARMACEUTICAL ENGINEERING
43
BP304T-PHARMACEUTICAL ENGINEERING
44
BP304T-PHARMACEUTICAL ENGINEERING
45
Disadvantages
 Expensive
 Need technical expert
 Not flexible
 Occupies more space
Advantages
 Power loss is less
 Head loss is negligible
Applications:
 It is commonly used for liquids, specially for water.
 It can also be used for the measurement of gases.
BP304T-PHARMACEUTICAL ENGINEERING
46
PITOT TUBE
• Principle:
 Pitot tube consists of sensing element with a small constriction
compared to the size of the flow channel.
 When the sensing element is inserted at the center of the stream,
the velocity of flow is increased.
 This results in decrease in pressure head.
∆Hp = u2 /2g
BP304T-PHARMACEUTICAL ENGINEERING
PITOT
TUBE
47
BP304T-PHARMACEUTICAL ENGINEERING
48
Construction
 It is also known as insertion meter or insertion tube
 The size of the sensing element is small compared to the flow channel
 The point of measurement may be at the center of the channel
 One tube is perpendicular to the flow direction and the other is parallel to the flow
 Two tubes are connected to the manometer
Working
 Tube are inserted in the flow shown is the figure.
 Pitot tube is used to measure the velocity head of the flow.
 In this tube velocity of fluid is increased at the narrow constriction which
results in decreased pressure.
BP304T-PHARMACEUTICAL ENGINEERING
 Tube at right angles to the flow measures pressure head only
while the tube that points upstream measures pressure head
and velocity head.
µ2= Cv √2g ∆H
 Cv coefficient of Pitot tube
49
BP304T-PHARMACEUTICAL ENGINEERING
50
ROTAMETER
Principle:
 Rotameter is known as area meter as it measures area of flow.
 It consist of a vertical, tapered and transparent tube in which plummet is
placed.
 During the fluid flow through the tube the plummet rises and falls because of
variation of flow.
BP304T-PHARMACEUTICAL ENGINEERING
51
BP304T-PHARMACEUTICAL ENGINEERING
Construction
 It consists of vertically tapered and transparent tube with narrow end down, in which a
plummet is placed.
 A solid plummet is placed in the tube. The diameter of the plummet is smaller than the
narrowest part of the tube.
 Floats/plummet is made up of glass, aluminium or plastic.
 The tube is usually made of glass on which linear scale is given.
 During the flow the plummet rise due to variation in flow
 The upper edge of the plummet is used as an index to note the reading
52
BP304T-PHARMACEUTICAL ENGINEERING
53
BP304T-PHARMACEUTICAL ENGINEERING
•SIZE REDUCTION
BP304T-PHARMACEUTICAL ENGINEERING 54
DEFINITION:
SIZE REDUCTION
5
5
 Size reduction is the operation carried out for reducing
the size of bigger particles into smaller one of desired size
and shape with the help of external forces.
 COMMINUTION is another term used for size reduction.
55
BP304T-PHARMACEUTICAL ENGINEERING
5
6
56
BP304T-PHARMACEUTICAL ENGINEERING
OBJECTIVES OF SIZE REDUCTION:
 Increase the surface area because, in most reactions
involving solid particles, the rate of reactions is directly
proportional to the area of contact with a second phase.
 Break a material into very small particles in order to
separate the valuable amongst the two constituents.
 Achieve intimate mixing.
 To dispose solid wastes easily .
 To improve the handling characteristics.
 To mix solid particle more intimately.
4
57
BP304T-PHARMACEUTICAL ENGINEERING
ADVANTAGES:
5
8
 Content uniformity
 Uniform flow
 Effective drying
 Increases surface area or viscosity
 Uniform mixing and drying
 Improve rate of absorption. particles
greater is absorption.
 Improve dissolution rate.
Smaller the
58
BP304T-PHARMACEUTICAL ENGINEERING
DISADVANTAGES:
5
9
 Drug degradation
 Contamination
59
BP304T-PHARMACEUTICAL ENGINEERING
MECHANISM OF SIZE REDUCTION:
 Impact- particle size reduced by a single rigid force
(hammer).
 Compression- in this mode material is crushed between
rollers by the application of pressure.
 Attrition- arising from particles scraping
against one another or against a rigid surface by
rubbing action.
 Cutting- the material is cut by means of sharp blades.
7
60
BP304T-PHARMACEUTICAL ENGINEERING
61
BP304T-PHARMACEUTICAL ENGINEERING
MECHANISMS AND LAWS
62
 The energy requirement for particle size reduction is a
function of input and output of particle size, hardness,
strength and other properties of solids.
 Various theories are:-
 Rittinger’s theory
 Kick’s theory
 Bond’s theory
for energy requirement
BP304T-PHARMACEUTICAL ENGINEERING
63
BP304T-PHARMACEUTICAL ENGINEERING
 Integrating equation (1),
E=C ln(di/dn) . . . . (2)
(di/dn) =reduction ratio.
If n=1.0equation (2)becomes Kick’s theory. If n=1.5equation
(2) becomes Bond’s theory.
Ifn=2.0equation (2) becomes Rittinger’s theory.
64
BP304T-PHARMACEUTICAL ENGINEERING
RITTINGER’S THEORY
13
• E= amount of energy
 According to this theory energy E required for size
reduction of unit mass is directly
area
proportional to the new surface produced.
E=KR (Sn – Si) …. (3)
Where
• Si = initial surface area
• Sn = new specific surface area
• KR = Rittinger’s constant.
65
BP304T-PHARMACEUTICAL ENGINEERING
BOND’S THEORY
 According to bond theory the energy used in crack propagation is
proportional to the new crack length produced.
 It states that energy required for deforming a set of particle of
equivalent shape is proportional to the change in particle
dimensions.
14
66
BP304T-PHARMACEUTICAL ENGINEERING
KICK’S THEORY:
 It states that energy required for deforming a set of particle of
equivalent shape is proportional to the ratio of the change in
particle size.
67
BP304T-PHARMACEUTICAL ENGINEERING
Rittinger’s theory:(n=2.0)
 Energy α new surface area formed.
• Bond’s theory:(n=1.5)
Energy used in crack propagation α Crack length
produced.
Energy α Ratio of change in particle dimensions.
Kick’s theory:(n=1.0)
Energy α Ratio of change in size.
16
68
BP304T-PHARMACEUTICAL ENGINEERING
69
BP304T-PHARMACEUTICAL ENGINEERING
CONSTRUCTION & WORKING
70
 A hammer mil is essential y a steel drum containing a vertical or
horizontal rotating shaft or drum on whichhammersare mounted.
 The hammers swings on the ends or fixed to the central rotor.
 The rotor is rotates at a high speed inside the drumwhile
materialisfed into a feed hopper.
 The material is put into the hopper which is connectedwith
the drum.
 The material is powdered to the desired size due to fast
rotation of hammers and is colected under the screen.
BP304T-PHARMACEUTICAL ENGINEERING
This are mainly
operated at
2500 rpm or
1000 to 2500
rpm for the
reduction of the
large
particles.
speed
sized
High
rotor
uses 10000 rpm
speed.
71
BP304T-PHARMACEUTICAL ENGINEERING
72
BP304T-PHARMACEUTICAL ENGINEERING
ADVANTAGES:
• It israpidin action,andiscapableof grindingmany different types of
materials.
• Theyare easyto instal and operate, the operation iscontinuous.
• There is little contamination of the product with metal abraded
from the mil as no surface move againsteach other.
• The particle size of the material to be reduced can be easily control
ed by changing the speed of the rotor, hammer type, shape and
sizeof the screen.
21
73
BP304T-PHARMACEUTICAL ENGINEERING
DISADVANTAGES:
 Heat buildup during milling is more, product
degradationispossible.
therefore,
 Hammer mills cannot be employed to mill sticky,fibrousandhard
materials.
 Thescreensmayget clogged.
22
74
BP304T-PHARMACEUTICAL ENGINEERING
BALL MILL:
 These are also knows as tumbling mills or pebble mills.
 Principle: The ball mill works on the principle of impact
between the rapidly moving balls and the powder material,
both enclosed in a hollow cylinder.
 At low speed the balls roll over each other attrition will be
mode of action thus in the ball mill attrition and impact
both mechanisms takes place.
23
75
BP304T-PHARMACEUTICAL ENGINEERING
 Construction:
 It consists of a hollow cylinder which is mounted on a metallic
frame in such a way that it can be rotated on its longitudinal axis.
 The length of the cylinder is slightly higher than its diameter.
 The cylinder contains balls that occupy 30 to 50% of the mill
volume.
 The ball size depends on the size of the feed and the diameter
of the mill. Ballsare made up of
steel, iron or stoneware
medium.
and act as grinding
24
76
BP304T-PHARMACEUTICAL ENGINEERING
77
BP304T-PHARMACEUTICAL ENGINEERING
 Working:
 The drug to be ground is put into the cylinder of the mill in such a
quantity that it is filled to about 60% of the volume.
 A fixed number of balls are introduced and the cylinder is closed.
The mill is allowed to rotate on its longitudinal axis.
 The speed of rotation is very important
26
78
BP304T-PHARMACEUTICAL ENGINEERING
Uses:
For fine grinding with a particle size of 100 to 5 mm or less.
For production of ophthalmic and parenteral products.
For milling dyes, pigments and insecticides at low speed.
27
79
BP304T-PHARMACEUTICAL ENGINEERING
ADVANTAGES:
80
 It can produce very fine powder.
 Ball mill is used for both wet and dry grinding processes.
 Toxic substances can be ground, as the cylinder is closed
system.
 Rod or bars can also be used as grinding media.
 Sticky material are size reduced in ball mill,
 Installation, operation and labor costs are low.
 Since the mill is closed system used for sterile products and
oxygen sensitive products.
BP304T-PHARMACEUTICAL ENGINEERING
DISADVANTAGES:
81
 The ball mill is a very noisy machine.
 Ball mill is a slow process.
 Soft, fibrous material cannot be milled by ball mill.
BP304T-PHARMACEUTICAL ENGINEERING
FLUID ENERGY MILL/ JET MILL/
MICRONIZERS/ ULTRAFINE GRINDERS
82
 Principle:
 Fluid energy mill operates on the principle of impact and attrition.
Milling takes place because of high velocity collisions between the
suspended particles.
 Construction:
 It consist of an elliptical pipe which has a height of about 2 meters
and diameter may be ranging from 20 to 200 mm.
BP304T-PHARMACEUTICAL ENGINEERING
83
BP304T-PHARMACEUTICAL ENGINEERING
 The mill surface may be made up of either soft stainless steel or
tough ceramics.
 Grinding nozzles are placed tangential and opposed to the initial
flow path of a powder.
 Compressed air is used at 600 kilopascals to 1 megapascals.
 Venturi feeder is provided in the path of the airflow. An outlet with
a classifier is fitted to allow the escape of air.
84
BP304T-PHARMACEUTICAL ENGINEERING
85
BP304T-PHARMACEUTICAL ENGINEERING
 Uses:
 To reduce the particle size of most of drugs such as antibiotics and
vitamins.
 Advantages:
 It has no moving parts heat is not produced during milling.
 It is rapid and efficient method for reducing powder to 30 mm or less.
 No contamination is possible.
 Disadvantages:
 Not suitable for milling of soft, tacky and fibrous
material.
 Equipment is expensive.
34
86
BP304T-PHARMACEUTICAL ENGINEERING
EDGE RUNNER MILL:
 Principle:
 The size reduction is done by crushing due to heavy weight of
stones.
 Construction:
 It consist of two heavy rollers and may weigh several tons.
 The roller move on a bed which is made up of granite or
stone.
 Each roller has a central shaft and revolve on its axis.
 The rollers are mounted on horizontal shaft and move
around the bed.
35
87
BP304T-PHARMACEUTICAL ENGINEERING
88
BP304T-PHARMACEUTICAL ENGINEERING
WORKING:
89
 The material to be ground is placed on the bed with the
help of the scrapper in such a way that it comes in the
path of the stone wheel.
 These stones revolve on its own axis and at the same time
travel around the shallow stone bed.
 The material is ground for definite period.
 The powder is collected and passed through a sieve to get
powder of required size.
BP304T-PHARMACEUTICAL ENGINEERING
90
BP304T-PHARMACEUTICAL ENGINEERING
END RUNNER MILL:
 Principle:
 Size reduction is done by crushing due to presence of
heavy weight steel pestle.
 Construction:
 It is considered as mechanical mortar pestle.
 It consist of a steel mortar which is fixed to a plate.
 The construction of mortar is connected to horizontal shaft
bearing a pulley so the plate with mortar can be rotated at
high speed.
 The pestle is dumb-bell shaped and bottom of pestle is flat. 39
91
BP304T-PHARMACEUTICAL ENGINEERING
40
92
BP304T-PHARMACEUTICAL ENGINEERING
 Construction of pestle is done in such a way that it can be
raised from mortar for cleaning and emptying.
 Working:
 The material to be ground is placed in the mortar. The scraper
puts the material in the path of the pestle.
 The mortar revolves at high speed and the pestle is placed in
the mortar.
 The revolving mortar causes pestle to revolve.
 The material is collected and passed through a sieve to get the
powder of desired size.
41
93
BP304T-PHARMACEUTICAL ENGINEERING
94
BP304T-PHARMACEUTICAL ENGINEERING
SIZE SEPERATION
BP304T-PHARMACEUTICAL ENGINEERING 95
Size Separation
A special technique is used to separate particles of
specified size which is known as the "process of size
separation".
OFFICIAL STANDARDS FO R POWDERS
The Indian Pharmacopoeia has laid down the standards
for powders for pharmaceutical purposes. The I.P.
specifies five grades of powder which are as under:
1. Coarse powder : A powder of which al! the particles pass
through a sieve with nominal mesh aperture of 1.70 mm
(No. 10 sieve) and not more than 40.0 per cent through a
sieve with nominal mesh aperture of 355 urn (No. 44
sieve) is called coarse powder.
2. Moderately coarse powder: A powder of which all the
particles pass through a sieve with nominal mesh
aperture of 710 nm (No. 22 sieve) and not more than 40.0
per cent through a sieve with nominal mesh aperture of
250 nm (No. 60 sieve) is called moderately coarse
powder.2
96
BP304T-PHARMACEUTICAL ENGINEERING
3. Moderately fine powder : If all the particles of apowder pass through a
sieve with nominal mesh aperture of 355 µm (No. 44 sieve) and not more
than 40.0 per cent through a sieve with nominal mesh aperture of 180
µm(No. 85 sieve), it falls in this group.
4.Fine powder : In case all the particles pass through a sieve with a
nominal mesh aperture of 180 µm (No. 85 sieve), it is called fine powder,
5.Very fine powder : If all the particles of the powder pass through a sieve
with a nominal mesh aperture of 125 µm (No. 120sieve), it is said to be very
fine powder.
SIEVES
Sieves for pharmacopoeial testing are constructed from wire cloth with square
meshes, woven from wires of brass, bronze, stainless steel or any other
suitable material. The wires should be of uniform circular cross-section and
should not be coated or plated. There should not be any reaction between the
material of the sieve and the substance which is being sifted from it.
3
97
BP304T-PHARMACEUTICAL ENGINEERING
4
98
BP304T-PHARMACEUTICAL ENGINEERING
Standards for sieves used for pharmacopoeial testing must specify the
following:
1.Number of sieve : Sieve number indicates the number of meshes in a length
of 2.54 cm in each transverse direction parallel to the wires.
2.Nominal size of aperture : Nominal size of aperture indicates the distance
between the wires. It represents the length of the side of the square aperture.
The I.P. has given the nominal mesh aperture size for majority of sieves in
mm or in cm.
3.Nominal diameter of the wire : Wire mesh sieves are made from the wire
having the specified diameter in order to give a suitable aperture size and
sufficient strength to avoid distortion of the sieve.
4.Approximate percentage sieving area : This standard expresses the area of
the meshes a percentage of the total area of the sieve. It depends on the size
of the wire used
for any particular sieve number. Generally the sieving
area is kept within the range of 35 to 40 per cent in ord5
er to give suitable
strength to the sieve.
99
BP304T-PHARMACEUTICAL ENGINEERING
5. Tolerance average aperture size : Some variation in theaperture
size is unavoidable and when this variation is expressed as a percentage,
it is known as the 'aperture tolerance average'.
SIEVING METHOD
In this method, the fine powder is separated from the coarse powder by using
sieves of desired number. The degree of fineness of a powder is known with the
help of sieve through which the powdered material is passed. Sieves are
numbered in order to distinguish from each other. Size separation of
powder is done by passing the powdered material through a set of sieves.
Sieves are arranged in descending order i.e. sieve of larger size is at the top
and the smallest one at the bottom. The bottom sieve is attached to the
receiving pan.
6
100