Skip to main content
ASSESSMENT OF HETEROPHORIA
Presented by: Suraj Kumar Sahani
Prabin Gautam
BOVS 6th batch, LEIRC
Introduction
■ Heterophoria is a condition where in the tendency of the eye to deviates
is kept latent by fusional reflex
■ Orthophoria is a condition where the visual axes of both eyes are directed
towards the fixation point and no deviate on dissociation
Evaluation of heterophoria
■ Examination of patient comprises of detailed history
■ Determination of visual acuity, refractive error by refraction including
(initial undilated retinoscopy)
■ Testing for ocular movement ( uniocular as well as binocular in all gaze)
■ Determination of phoria by cover-uncover test
■ Measurement of heterophoria
■ Measurement of convergence, accommodation and AC/A ratio
■ Measurement of fusional reserve
■ Assessment of state of binocular vision
Cover-uncover test
■ It should be performed for both distance and near
■ One eye of patient is covered with occluder while fixating with other eye
at near or distance target. The eye is then uncovered after few second and
refixation movement is noted
■ After the cover is removed, the speed and smoothness of refixation
indicates the strength of motor fusion
■ The direction of deviation, degree of deviation and speed of recovery is
noted
■ No movement: if the uncovered eye doesn’t move when covered and the
covered eye doesn’t move when uncovered, the patient has normal
binocular alignment (orthophoria)
■ Covered eye moves to fixate when uncovered: phoria present
■ Refixation movement toward nasal upto Central : exophoria
■ Refixation movement toward temporal upto central : esophoria
Measurement of heterophoria
■ Objective test : prism and cover test
■ Subjective test :
1. Maddox rod test
2. Maddox wing test
3. Double prism test
4. Von Graefe method
5. Modified Thorington test
6. Synaptophore method
Prism and cover test
■ Objective method of measuring phoria
■ Test should be performed for both near and distance
■ Prism with Apex towards the deviation placed in front of one eye and the
patient is asked to fixate a target with the other eye
■ Alternate cover test is performed till there is no recovery movement of
the eye under cover
■ Amount of deviation in prism diopter is noted with base orientation
Maddox rod test
■ Principle : dissociation of fusion image
■ Equipment Required
1. Maddox Rod: A red lens made up of series of parallel glass cylinder
(Plano convex) of higher power that converts a point source of light into a
line or streak.
2. Small Fixation Light: A penlight or fixed target light used as the point
source.
3. Prism Bar (or Loose Prisms): Used to neutralize and measure the
amount of deviation (measured in prism diopters, PD).
4. Trial Frame: To hold the Maddox Rod and prisms.
Procedure
■ Room should be dimmed and patient should wears their refractive
correction of best vision distance or near
■ The patient should fixates on the point source of light with both eye open
■ The Maddox rod is placed in front of RE ( that eye see a line streak
perpendicular to the rod’s cylinder ) and LE sees the point source of light
MEASURING HORIZONTAL PHORIA
■ Rod‘s cyl is oriented horizontally and vertical streak is seen
■ The patient is asked whether the vertical red streak and point light is
coincide or the red streak is to the left or right of point source
■ If coincide – orthophoria
■ If vertical red streak is at right side of point source then esophoria BO
prism is required to coincide these two
■ If vertical red streak is at left side of point source then exophoria BI
prism is required to coincide these two
■ The pd of prism by which they coincide gives the amount of deviation in
pd
Maddox wing test
 Maddox wing consists of:
1. The handle
2. The eye piece
3. The eye-piece lens holder
4. The septa(2)
5. The scale card
6. The torsion lever
Maddox wing test
■ Subjective method of measuring phoria for near only
■ Based on principle of dissociation of fusion by dissimilar object
■ The instrument is designed in such a way that when the patient looks
through the eyepiece of the instrument, the right eye sees a vertical white
arrow and a horizontal red arrow, while the left eye sees a vertical and
horizontal line of numbers.
The patient is asked to tell the number on the horizontal line to which the vertical white
arrow is pointing (this will give the amount of horizontal phoria)
the number on the vertical line at which the red arrow is pointing this will measure the
vertical phoria
■ The cyclophoria is measured by asking the patient to align the red arrow with the
horizontal line of number
Double prism test
■ Double prism test consists of two prisms which are mounted base to base to
elict cyclophoria
■ double prism is placed before one eye in such a manner that the junction of the
two bases intersects the pupil and is horizontal
■ Then the patient is asked to look at a horizontal line against an empty
background which does not offer any fusional stimuli and inferences drawn are
as follows:
■ Patient will see two parallel lines with the eye having double prism in front of
it, i.e. one line displaced above and the other displaced below with respect to
the single line seen by the other eye.
■ In the absence of any cyclophoria, all three lines will be parallel.
■ If a cyclophoria is present, the single line will have an angle relative to
the other two lines as follows:
■ In incyclophoria , the line or lines seen by the right eye will be tilted
towards right and those seen by left eye will be tilted towards left.
■ In excyclophoria, the line or lines seen by the right eye will be tilted
towards left and those seen by left eye will be tilted towards right.
Von Graefe method
■ Subjective test for evaluating the presence, direction, and the magnitude
of the phoria
■ Equipment required: phoropter or trial frame , isolated 20/30 target, risley
prism or prism bar in trial frame ( 6 pd and 12 pd)
■ Procedure: MEASURING HORIZONTAL PHORIA
1. Patient is instructed to see the target
2. A vertical prism of 6 pd as dissociating prism is placed in front of one
eye and a 12 pd base in as measuring prism in other eye
3. If BU in LE and BI in RE, lower image toward left is seen by LE and
upper image towards right is seen by RE
4. The strength of the measuring prism is decreased until both image are on
same line
5. If image are on same line in 0 pd, it is orthophoric But if measuring prism
indicate BI prism at alignment the pt. is exophoric and if it indicate BO the
pt. is esophoric of that pd
MEASURING VERTICAL PHORIA
1. Patient is instructed to see the target
2. A vertical prism of 6 pd (BU or BD) as measuring prism is placed in
front of one eye and a 12 pd base IN as dissociation prism in other eye
3. Pt. is asked to report when the two letters are on same horizontal level
4. Measuring prism is reduced until the pt. Report alignment
■ If the measuring prism is BU in LE, and if alignment obtained at
■ O pd – orthophoric
■ BU – left hypophoria
■ BD-left hyperphoria or right hypophoria
Modified thorington method
■ Principle: Maddox rod used to dissociate the eyes preventing binocular
fusion
■ Equipment required: Maddox rod , thorington card and penlight or
transilluminator
■ Procedure:
1. The patient should wear their near and distance vision correction glasses
2. The patient hold the Maddox rod before the RE with the striation of
Maddox rod oriented toward the direction of deviation
3. Hold the thorington card 40 cm with penlight behind central hole of card
4. Instruct the patient to look directly at the centre of the card
5. The patient should see a red vertical line if horizontal phoria or red
horizontal line if vertical phoria
6. Ask the patient to report the number through which the line is passing and
whether it is left or right of the zero or above or down the zero
If Maddox rod is in RE:
• Line is passing left to zero crossed type =exophoria
• Line is passing right to zero uncrossed = esophoria
• Line passing above to zero = RE hypophoria
• Line is passing below to zero= RE hyperphoria
Synaptophore method
Heterophoria and heterotropia can be measured accurately by both objective
and subjective method
The synoptophore uses the haploscopic principle, presenting separate images
to each eye to fully dissociate them, revealing any latent deviation (phoria)
or manifest deviation
■ The measurement is done by adjusting the angle of the instrument’s tubes
until the visual axes are aligned according to either the examiner’s
observation (objective) or the patient’s perception (subjective).
Objective method
■ The objective method relies on the examiner's observation of eye
movements and does not require a verbal response from the patient,
making it suitable for young children or those with communication
difficulties.
■ Procedure:
■ Preparation and Instrument Setup
■ Seat the patient comfortably with their chin on the chin rest and
forehead against the headrest.
■ Adjust the instrument’s Pupillary Distance (PD) dials to match the
patient’s PD.
– Set the horizontal, vertical, and torsional scales to zero (0).
■ Insert Simultaneous Macular Perception (SMP) slides (e.g., a Lion and a Cage ) into
the slide carriers of both tubes. These slides present dissimilar images to each eye,
which is essential for revealing a heterophoria.
■ Using the alternate flashing device (or an external occluder) to rapidly switch
illumination between the two tubes, alternate stimulation between the eyes. This
completely dissociates the eyes if refixation movement present
■ Slowly adjust the horizontal and/or vertical arm of the Synoptophore corresponding to
the direction of the deviation until no refixation movement is observed until no
movement
■ If no movement is detected, the objective angle of deviation (OAD) is found. This is
the magnitude of the heterophoria.
Subjective method
■ The subjective method relies on the patient's perception and their ability
to superimpose the two images
■ Procedure: Simultaneous Perception slides are used and the lights for
both slides are kept on continuously.
■ The patient is asked to superimpose the images (e.g., put the lion in the
cage) by moving the tubes until the images are perceived as a single,
combined image
■ The measurement on the scale at this position is the subjective angle of
deviation.In a patient with normal retinal correspondence (ARC), the
subjective angle will be the same as the objective angle. A difference
between the two indicates abnormal retinal correspondence, which is
common in constant strabismus.
Reference
Noorden GK von, Campos EC. Binocular Vision and Ocular Motility:
Theory and Management of Strabismus. 6th
edition. Mosby. 2002:7-37.
Billson FA. Fundamentals of Clinical Ophthalmology: Strabismus. BMJ
Books. 2003:8-19.
Khurana AK. Anatomy and Physiology of Eye. 2nd
edition. CBS Pub.
2006:327-364.
■ Mukherjee PK. Pediatric Ophthalmology. New Age Int Pub. 2005:637-
672