  1. 1. www.E-Inst.com P: (215) 750-1212 F: (215) 750-1399 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 2017 Product Catalog Built With Quality In Mind Emiss ions Analyzers Combustion Ana lyzers Ind oor Air Quality Automotive Emiss ions
  2. 2. E Instruments International Built With Quality In Mind The E Instruments organization is a privately held company originally incorporated in 2001 by experts with over 30 years of experience in design manufacturing and industrial applications. The initial business mission was to provide high quality instrumentation designed to measure the flue gas emissions from industrial applications. After many years of successful growth and recognition in the international markets, the company was incorporated as E Instruments International LLC with the expanded mission to design, manufacture and market a complete range of innovative instrumentation solutions encompassing portable Emissions, Exhaust, and Combustion Analyzers, and Indoor Air Monitors especially designed for the industrial, HVAC, commercial, automotive, and institutional markets worldwide. E Instruments’ continued success is based on our commitment to: With manufacturing facilities in the USA and Europe, our team continues to grow and we are currently exporting to over 65 countries worldwide. ABOUT US 1) Design instruments to meet our customer’s needs 2) Apply our expertise to monitoring unique and specialized applications 3) Deliver Analyzers and Monitors Built with Quality in Mind 4) Provide excellent Customer Support
  3. 3. Contents HVAC Combustion Analyzers Page 4-19 Portable Emissions Analyzers Page 20-33 Indoor Air Quality Monitors Page 42-57 & Calibration Services NONNNNNNNOOOOOOO CH O2 CO2CCCCCOOOOOO22222222 SSSSSSS2H CCCOOO % RH%%%% RRRHHHH%%%% RRRRRHHHHH NO2NNNNNNNNNNNOOOOOOOO22222222 SO2 O2 Quality Control, Customer Support Qualified customer support & technical specialists will work with you and your team with any product and application questions you may have on a timely manner. We appreciate that your time is precious and that your analyzers/instruments are important tools for your business. Our modern Calibration Laboratories provide high quality calibration services and certificates using EPA protocol gases and NIST traceable calibration standards. Additional traceable calibration services are offered at our ISO 17025 & ISO 9001 accredited laboratory. Our Distribution network offers sales and technical product support in many countries around the world. E Instruments’ quality control premise encompasses the complete business process from design, manufacturing, administration, customer support, and after sale Calibration & repair Services. Our team of qualified professionals is fully committed to our basic philosophy of “Built with Quality in Mind”, which applies to all products and services offered by our company. Automotive Exhaust Gas Analyzers Page 34-41
  4. 4. Markets & Applications ‡ Boiler, Furnace, and Burner Manufacturers ‡ Residential, Commercial,& Light Industrial ‡ Condensing Boilers and Furnaces ‡ Boilers, Furnaces, and Heaters ‡ HVAC & Controls Wholesale ‡ HVAC Technical Schools ‡ Retail, Malls, Hotels ‡ Energy Auditing ‡ Weatherization ‡ Hospitals ‡ Schools Built With Quality In Mind HVAC Product Line
  5. 5. Combustion Analyzers 4500 O2, CO, NO NO2, SO2 7899 Gas Leak Detector 1500 O2, COO2, C900 O2, CO, NO, CxHy O2, C C700 O2, CO
  6. 6. Built With Quality In Mind ‡ Gas & Diesel Engines ‡ Laboratory Analysis ‡ Gas Turbines ‡ Incinerators ‡ Furnaces ‡ Heaters ‡ Boilers ‡ Kilns Applications Relevant Markets ‡ Chemical & Industrial Processes ‡ Cement & Mineral Processing ‡ Natural Gas Compression ‡ Universities & Research ‡ Utilities & Power Plants ‡ Power Generation ‡ Petrochemical ‡ Heat Treating ‡ Biomass ‡ Marine ‡ Mining Industrial Product Line
  7. 7. Emissions Analyzers 1500 O2, COO 4500 O2, CO, NO NO2, SO2, CxHy E8500 Plus Up to 9 Gas Sensors O2, CO, NO, NO2, SO2, H2S NDIR: CO2, High CO, CxHy PID: VOC O 2, 6000 O2, CO, NO NO2, SO2, CxHy, H2S (Max 4 Gas Sensors) (4 or 5 Gas Sensors) 4 Gas Sensors)4 Gas E9000 Up to 9 Gas Sensors O2, CO, NO, NO2, SO2, H2S NDIR: CO2, High CO, CxHy Heated Sample Line
  8. 8. Built with Quality in MindFor Boiler & Burner Set-Up, Servicing, & Maintenance Economical Residential Combustion Analyzer Robust Fast Reliable Accurate CO CO2 O2 Draft & Differential Pressure Built-In Manometer Ambient CO Monitor Flue & Ambient Temp CO Sensor with NOx Filter Combustion Efficiency PC Software w/ Auto Saving Unbreakable Metal Connections 5 Tools-In-One TRUE High- Efficiency for ALL Condensing Systems TTTT ffi i Automatic, EfEf TRUE High y f d i S t TTTTatic, Calculations Field ReplaceableFiFieldFie Pre-Calibrated Sensors Wireless Bluetooth™ PrinterWirreWire Built with QuaMaintenance ure p Ox Filter iency g i ns e E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com
  9. 9. CO CO˺ Tair Tgas Differential Temp Pressure/Draft Excess Air Efficiency Warranty Electrochemical Calculated Pt100 Tc K Calculated Calculated Calculated Semiconductor 2 years: Analyzer + Sensors 0 - 8000 ppm 0 - 99.9% -10 to 212°F -10 to 1830°F -10 to 1830°F ±0 - 80 inH˺0 0 - 850% 0 - 100% 1 ppm 0.1% 0.1°F 0.1°F 0.1°F 0.001 inH˺0 1% 0.1% Parameter Sensor ResolutionRange Accuracy O˺ Electrochemical 0 - 25% 0.1% ±0.2% vol ±8 ppm <400 ppm ±1°F ±1% rdg. ±2°F Built with Quality in Mind Ordering Information Model No. Description 700 - A 700 - AP Model 700 Kit = O˺, CO, CO˺, Draft, Diff. Pressure, Flue/Air Temperature, Efficiency, Excess Air, 300 Internal Test Memory, PC Software Included + New Auto Outdoor Air Temp. Saving for TRUE Efficiency Calculations Model 700 Kit w/ Printer = O˺, CO, CO˺, Draft, Diff. Pressure, Flue/Air Temperature, Efficiency, Excess Air, 300 Internal Test Memory, PC Software Included + Wireless Bluetooth™ Printer + New Auto Outdoor Air Temp. Saving for TRUE Efficiency Calculations E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com ˒ New Auto Outdoor Air Temp ˒ O˺, CO, CO˺ ˒ Combustion Efficiency, Losses, & Excess Air ˒ CO Air Free ˒ Draft & Differential Pressure ˒ Temperature Measurements ˒ 300 Test Internal Memory ˒ Bluetooth Connectivity ˒ Long Lasting Rechargeable Battery & AC Charger ˒ Gas Sampling Probe & Hoses ˒ Water Trap with Filter Cartridge ˒ Operating Manual ˒ Calibration Certification All Model 700 Kits Include: ˒ Magnetic Rubber Holster ˒ PC Software & USB Cable ˒ Vinyl Carrying Case ˒ ɟÞNjsĶsǣǣ DĶȖsǼŸŸǼÌ˗ ƻNjÞŘǼsNj Optional Wireless Bluetooth™ Printer (No More Lining Up Infrared Printers!) NNNEEEWW!!! Internal Memory & PC Software Included Pre-Calibrated Field Replaceable Sensors 10 Fuel / Oil Types Including Bio-Heat 5% Unbreakable Metal Connections Outdoor Air Temp. & High Efficiency (Condensing Systems) H˺ Compensated w/ Built-In NOx Filter ±10 % rdg for >2000 ppm ±5% rdg up to 2000 ppm O Air Temp & Automatic mpppp. & Higggh y sing Systems) Calculations AA Options:
  10. 10. The Latest in Combustion Analysis Technology CO CO2 O2 Field Replaceable SensorsFiFieFi Robust Fast Reliable Accurate E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind Wireless Bluetooth™ Printer N o w W ith WirelessBl uetooth™ Printer Economical Combustion & Emissions Analyzer Upgradeable to NO/NOxUpgU Draft & Differential Pressure Built-In Manometer Ambient CO Monitor Flue & Ambient Temp Upgradeable to NO/NOx Combustion Efficiency PC Software w/ Auto Saving Unbreakable Metal Connections TRUE High- Efficiency for ALL Condensing Systems TTT Effi i Automatic, E TRUE High y f d i S t TTTatic, Calculations 5 Tools-In-One NOx d Replaceablieldie eless Bluetooth™ PrinterWiWireWir N o w W ith WirelessBl uetooth™ Printer mp o NO/NOx Efficiency In-One
  11. 11. Built with Quality in Mind Ordering Information Model No. Description 900 - 2 900 - 3 900 - 3P Base Kit = O˺, CO, CO˺, Upgradeable to NO/NOx, Draft, Diff. Pressure, Flue/Air Temperature, Efficiency, Excess Air, 600 Internal Test Memory, PC Software Included + New Auto Outdoor Air Temp. Saving for TRUE Efficiency Calculations 900 - 2P Base Kit w/ Printer = O˺, CO, CO˺, Upgradeable to NO/NOx, Draft, Diff. Pressure, Flue/Air Temperature, Efficiency, Excess Air, 600 Internal Test Memory, PC Software Included + Wireless Bluetooth™ Printer + New Auto Outdoor Air Temp. Saving for TRUE Efficiency Calculations NOx Base Kit = O˺, CO, CO˺, NO/NOx Included, Draft, Diff. Pressure, Flue/Air Temperature, Efficiency, Excess Air, 600 Internal Test Memory, PC Software Included + New Auto Outdoor Air Temp. Saving for TRUE Efficiency Calculations NOx Kit w/ Printer = O˺, CO, CO˺, NO/NOx Included, Draft, Diff. Pressure, Flue/Air Temperature, Efficiency, Excess Air, 600 Internal Test Memory, PC Software Included + Wireless Bluetooth™ Printer + New Auto Outdoor Air Temp. Saving for TRUE Efficiency Calculations E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com ˒ New Auto Outdoor Air Temp ˒ O˺, CO, CO˺ ˒ Upgradeable to NO/NOx ˒ Combustion Efficiency, Losses, & Excess Air ˒ CO Air Free ˒ Draft & Differential Pressure ˒ Temperature Measurements ˒ 600 Test Internal Memory ˒ Bluetooth Connectivity ˒ Long Lasting Rechargeable Battery & AC Charger ˒ Gas Sampling Probe & Hoses ˒ Water Trap with Filter Cartridge ˒ Magnetic Rubber Holster ˒ PC Software & USB Cable ˒ Operating Manual ˒ Calibration Certification ˒ Vinyl Carrying Case ˒ ŷƼǼÞŸŘ Ķ ɟÞNjsĶsǣǣ DĶȖsǼŸŸǼÌ˗ ƻNjÞŘǼsNj All Model 900 Kits Include: Optional Wireless Bluetooth™ Printer (No More Lining Up Infrared Printers!) NNEEWW!!! Internal Memory & PC Software Included Pre-Calibrated Field Replaceable Sensors 10 Fuel / Oil Types Including Bio-Heat 5% Unbreakable Metal Connections Outdoor Air Temp. & High Efficiency (Condensing Systems) CO CO˺ NO NOx Tair Tgas Differential Temp Pressure/Draft Excess Air Efficiency Warranty Electrochemical Electrochemical Calculated Calculated Pt100 Tc K Calculated Calculated Calculated Semiconductor 2 years: Analyzer + Sensors 0 - 8000 ppm 0 - 99.9% 0 - 4000 ppm 0 - 5000 ppm -10 to 212°F -10 to 1830°F -10 to 1830°F ±0 - 80 inH˺0 0 - 850% 0 - 100% 1 ppm 0.1% 1 ppm 1 ppm 0.1°F 0.1°F 0.1°F 0.001 inH˺0 1% 0.1% Parameter Sensor ResolutionRange Accuracy O˺ Electrochemical 0 - 25% 0.1% ±0.2% vol ±8 ppm <400 ppm ±5 ppm <100 ppm ±5% rdg up to 1000 ppm ±10% rdg for >4000 ppm ±1°F ±1% rdg. ±2°F H˺ Compensated w/ Built-In NOx Filter ±10 % rdg for >2000 ppm ±5% rdg up to 2000 ppm O Air Temp & Automatic mpppp. & Higggh y sing Systems) Calculations AA
  12. 12. The Latest in Combustion Analysis Technology CO CO˺ O2 Field Replaceable SensorsFiFieFie Robust Fast Reliable Accurate E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind Wireless Bluetooth™ Printer Combustion & Safety Analyzer Measure CxHy Hydrocarbons for SafetyMeaM Draft & Differential Pressure Built-In Manometer Ambient CO Monitor Flue & Ambient Temp Burner/Boiler Safety Combustion Efficiency PC Software w/ Auto Saving Unbreakable Metal Connections Ideal for Maintaining & Troubleshooting Residential Commercial Burners 5 Tools-In-One CxHy d Replaceablelde eless Bluetooth™ PrinterWiWireWir p afety Efficiency n-One
  13. 13. CO CO˺ Tair Tgas Differential Temp Pressure/Draft Excess Air Efficiency Warranty Electrochemical Calculated Pt100 Tc K Calculated Calculated Calculated Semiconductor 2 years: Analyzer + Sensors 0 - 8000 ppm 0 - 99.9% -10 to 212°F -10 to 1830°F -10 to 1830°F ±0 - 80 inH˺0 0 - 850% 0 - 100% 1 ppm 0.1% 0.1°F 0.1°F 0.1°F 0.001 inH˺0 1% 0.1% Parameter Sensor ResolutionRange Accuracy O˺ Electrochemical 0 - 25% 0.1% ±0.2% vol ±10 ppm <400 ppm ±1°F ±1% (-4.014 - 0.806 inH˺0) ±0.008 (-0.802 - 0.802 inH˺0) ±1% (0.806 - 0.292 inH˺0) ±2°F Built with Quality in Mind Ordering Information Model No. Description 900 - C CxHy Base Kit = O˺, CO, CO˺, CxHy Included, Draft, Diff. Pressure, Flue/Air Temperature, Efficiency, Excess Air, 600 Internal Test Memory, PC Software Included + New Auto Outdoor Air Temp. Saving for TRUE Efficiency Calculations 900 - CP CxHy Kit w/ Printer = O˺, CO, CO˺, CxHy Included, Draft, Diff. Pressure, Flue/Air Temperature, Efficiency, Excess Air, 600 Internal Test Memory, PC Software Included + Wireless Bluetooth™ Printer + New Auto Outdoor Air Temp. Saving for TRUE Efficiency Calculations E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com Optional Wireless Bluetooth™ Printer NNEEWW!! Pre-Calibrated Field Replaceable Sensors 10 Fuel / Oil Types Including Bio-Heat 5% Unbreakable Metal Connections Outdoor Air Temp. & High Efficiency (Condensing Systems) H˺ Compensated w/ Built-In NOx Filter ±10 % rdg for >2000 ppm ±5% rdg up to 2000 ppm O Air Temp & Automatic mpppp. & Higggh y sing Systems) Calculations AA CxHy (HC) Pellistor 0 - 5% 0.01% ±5% Full Scale Troubleshoot Burner Defects Draft/Air Supply Malfunction Damaged or Clogged Burner Tip
  14. 14. Residential & Commercial COMBUSTION ANALYZER The Latest in Combustion Analysis Technology CO CO2 O2 BUILT-IN PrinterBUIIUI Full COLOR Graphic DisplayFulFullFull Field Replaceable SensorsFiFielFie Robust Fast Reliable Accurate 5 Tools-In-One Built-In Manometer Ambient CO Monitor Flue & Ambient Temp Draft & Differential Pressure Combustion Efficiency E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com ial USTIOCOMBUS LLT IN PrinterLTI One r Temp ential Pressure Built with Quality in Mind PC Software w/ Auto Saving r Unbreakable Metal Connections , TRUE High- Efficiency for ALL Condensing Systems EEffii iiE Automatic TTRRUUE High yy f d i S t ,,,,attiicc Calculations ols-In-OOne
  15. 15. resse E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind O˺ CO CO˺ Tair Tgas Differential Temp. Pressure/Draft Excess Air Efficiency Warranty Parameter H˺ Compensated w/ Built-In NOx Filter Sensor Electrochemical Electrochemical Calculated Pt100 Tc K Calculated Semiconductor Calculated Calculated Range Resolution Accuracy 0 - 25 % 0 - 8000 ppm 0 - 99.9% -10 to 212 ̿F -10 to 1830 ̿F -10 to 1830 ̿F ±0 - 80 inH˺O 0 - 850% 0 - 100% 0.1 % 1 ppm 0.1 % 0.1 ̿F 0.1 ̿F 0.1 ̿F 0.001 inH˺O 1 % 0.1 % ±0.2 % vol ±8 ppm <400 ppm ±5 % rdg up to 2000 ppm ±10 % rdg for >2000 ppm ±1 ̿F ±2 ̿F ±1 % rdg. 2 years: Analyzer + Sensors Ordering Information Model No. Description 1500-1 Model 1500 Base Kit = Analyzer w/ O˺, CO, CO˺, Efficiency, Excess Air, Draft, Pressure, Temp, Rechargeable Battery & AC Plug, 10’ Dual Hose, 12” Probe, Vinyl Case, Calibration Certificate, Operating Manual, Cheat Sheet, Water Trap, Paper Roll, 2000 Internal Data Storage, PC Software, Bluetooth™ Connectivity, Automatic Outdoor Air Temperature Saving for ALL 90%+ Systems & Condensing Systems for TRUE Efficiency Calculations + Built-In Printer + New Android App Included 1500-Oil Standard 1500-1 Kit PLUS: Oil Smoke Pump, Smoke Filter Papers, and Comparison Chart PC Software, Bluetooth, & App Included Large Color Graphic Display All Model 1500 Kits Include: Magnetic Rubber Holster Pre-Calibrated Field Replaceable Sensors BUILT-IN PRINTER (NON-Fading Paper) Simple Menu Interface Full COLOR Graphic Display Unbreakable Metal Connections Outdoor Air Temp. & High- Efficiency (Condensing Systems) ˒ New Android App ˒ New Auto Outdoor Air Temp. ˒ Built-In Printer ˒ Large Color Display ˒ O˺, CO, CO˺ ˒ Combustion Efficiency, Losses, Excess Air ˒ CO Air Free ˒ Draft & Differential Pressure ˒ Temperature Measurements ˒ 2000 Test Internal Memory ˒ Bluetooth Connectivity ˒ Long Lasting Rechargeable Battery & AC Charger ˒ Gas Sampling Probe & Hose ˒ Water Trap with Filter Cartridge ˒ Magnetic Rubber Holster ˒ PC Software & USB Cable ˒ Operating Manual ˒ Calibration Certificate ˒ Carrying Case O Air Temp &A Automatic mppp. & High- y sing S stems) Calculations
  16. 16. Industrial Combustion Gas & Emissions Analyzer CO CO2 O2 Robust Fast Reliable Accurate Internal Memory (2000 Tests) 2 Channel Thermometer CO Sensor w/ NOx Filter Draft & Differential Pressure E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com is & Emi re Built with Quality in Mind BUILT-IN PrinterBUILFull COLOR Graphic DisplayFull Customizable Display Screen & Print-Out Pre-Calibrated, Field Replaceable Gas Sensors Combustion Efficiency Up To FOUR Gas Sensors NO2 SO2 NO NOx CxHy (HC) Handheld Versatile Gas Analyzer for Emissions Monitoring of Boiler, Engine, Furnace, and Other Combustion Applications Dilution Pump For CO Auto-Range Measurements Up To 10% PC Software with Bluetooth Total NOx Capable NEW Sample Conditioning Unit For Low NOx & Low SO2 Applications Automatic Data Saving N SSam ple Conditioning Unit For Low NOx & SO2
  17. 17. E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind Sample Conditioning Unit For Low NOx & SO˺ Applications Removes Moisture at the Probe For More Accurate Low NOx & SO2 Measurements O˺ CO CO˺ Tair Tgas Pressure/Draft Excess Air Efficiency Parameter H˺ Compensated w/ Built-In NOx Filter Sensor Electrochemical Electrochemical Calculated Pt100 Tc K Semiconductor Calculated Calculated Range Resolution Accuracy 0 - 25 % 0 - 8000 ppm 0 - 99.9% -10 to 212 ̿F -4 to 2280 ̿F ±0 - 80 inH˺O 0 - 850% 0 - 100% 0.1 % 1 ppm 0.1 % 0.1 ̿F 0.1 ̿F 0.001 inH˺O 1 % 0.1 % ±0.2 % vol ±8 ppm (0 - 200ppm) ±5 % rdg (201 - 2000ppm) ±10 % rdg (2001 - 8000ppm) ±1 ̿F ±0.5 ̿C (-20 to 100 ̿C) ±1.0% rdg CO DILUTED Electrochemical 0.8% - 10.00% 0.01% ±10% rdg NO Electrochemical NO˺ Electrochemical Low NO and/or Low NO˺ NOx Calculated SO˺ Electrochemical Electrochemical 0 - 5000 ppm 0 - 1000 ppm 0 - 100.0 ppm 0 - 5000 ppm 0 - 5000 ppm 1 ppm 1 ppm 0.1 ppm 1 ppm 1 ppm ±5 ppm (0 - 100 ppm) ±5% rdg (101 - 5000ppm) ±5 ppm (0 - 100 ppm) ±5% rdg (101 - 1000ppm) ±1.5 ppm (0.0 - 40.0ppm) ±5% rdg (40.1 - 100.0ppm) ±5 ppm (0 - 100ppm) ±5% rdg (101 - 5000ppm) -20 to 1250 ̿C -10 to 100 ̿C ±1 ̿C ̝˟ʳˤ̇ Nj_¶ ʹˠ˟ˠ ǼŸ ˠˡˤ˟ ̿C) 0.1 ̿C 0.1 ̿C Ordering Information Model No. Description 4500 with O˺, CO, NO/NOx, SO˺ Gas Sensors & CO Dilution Auto-Range to 50,000 ppm 4500 with O˺, CO, NO/NOx Gas Sensors Installed, Upgradeable to 4th Gas Sensor4500-3 4500 with O˺, CO, NO/NOx, NO˺ Gas Sensors & CO Dilution Auto-Range to 50,000 ppm4500-N 4500-S Probes & Hoses Standard: 12”, 300mm Probe, 1470̿F/800̿C max with 10’/3m Dual Hose Long: 30”, 750mm Probe, 1470̿F/800̿C max with 10’/3m Dual Hose Long & High Temp: 40”, 1m Probe, 2190̿F/1200̿C max, with 10’/3m Hose Hose Extensions: 10’/3m Length Available All Model 4500 Kits Include: ˒ Built-In Printer ˒ Draft & Differential Pressure ˒ Temperature Measurements ˒ Calculation for CO˺, Efficiency & Excess Air ˒ Rechargeable Batteries & AC Charger ˒ Gas Sampling Probe & Hoses ˒ Water Trap with Filter Cartridge ˒ Magnetic Rubber Holster ˒ 2000 Test Internal Memory ˒ PC Software & USB Cable ˒ Bluetooth Module (Internal) ˒ Operating Manual ˒ Calibration Certificate ˒ ABS Hard Plastic Carrying Case 4500 with O˺, CO, NO/NOx, CxHy (HC) Gas Sensors & CO Dilution Auto-Range to 50,000 ppm4500-C CxHy (HC) Pellistor 0 - 5% 0.01% ±5% Full Scale Bulletin:E4500.3Ed.01/2017Information&designsubjecttochangeatmanufacture’sdiscretion Low SO˺ Electrochemical 0 - 100.0 ppm 0.1 ppm ±1.5 ppm (0.0 - 40.0ppm) ±5% rdg (40.1 - 100.0ppm) 4500-NLow 4500-SLow 4500 with O˺, CO, Low NO/NOx, Low NO˺ Gas Sensors & CO Dilution Auto-Range to 50,000 ppm 4500 with O˺, CO, NO/NOx, Low SO˺ Gas Sensors & CO Dilution Auto-Range to 50,000 ppm High Temperature Probe & Sintered Filter Available P eeeeree ed FFilter Avvailableinte& Sintered FFilter Av
  18. 18. Six Gas Industrial Emissions Analyzer CO CO2 O2 Robust Fast Reliable Accurate Internal Memory (2000 Tests) Low NOx & Low SO˺ Capable CO Sensor w/ NOx Filter Draft & Differential Pressure E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com Capable r ure Built with Quality in Mind BUILT-IN PrinterBUILFull COLOR Graphic DisplayFull Customizable Display Screen & Print-Out Pre-Calibrated, Field Replaceable Gas Sensors Combustion Efficiency Up To SIX Gas Sensors Hand-Held Versatile Gas Analyzer for Emissions Monitoring of Boiler, Engine, Furnace, and Other Combustion Applications Dilution Pump For CO Auto-Range Measurements Up To 10% PC Software with Bluetooth Total NOx Capable NEW Sample Conditioning Unit For Low NOx & Low SO˺ Applications Automatic Data Saving Sam ple Conditioning Unit For Low NOx & SO2 NO˺ SO˺ NO NOx CxHy (HC) H˺Ǣ
  19. 19. E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind Sample Conditioning Unit For Low NOx & SO˺ Applications Removes Moisture at the Probe For More Accurate Low NOx & SO2 Measurements O˺ CO CO˺ Tair Tgas Pressure/Draft Excess Air Efficiency Parameter H˺ Compensated w/ Built-In NOx Filter Sensor Electrochemical Electrochemical Calculated Pt100 Tc K Semiconductor Calculated Calculated Range Resolution Accuracy 0 - 25 % 0 - 8000 ppm 0 - 99.9% -10 to 212 ̿F -4 to 2280 ̿F ±0 - 80 inH˺O 0 - 850% 0 - 100% 0.1 % 1 ppm 0.1 % 0.1 ̿F 0.1 ̿F 0.001 inH˺O 1 % 0.1 % ±0.2 % vol ±8 ppm (0 - 200ppm) ±5 % rdg (201 - 2000ppm) ±10 % rdg (2001 - 8000ppm) ±1 ̿F ±0.5 ̿C (-20 to 100 ̿C) ±1.0% rdg CO DILUTED Electrochemical 0.8% - 10.00% 0.01% ±10% rdg NO Electrochemical NO˺ Electrochemical Low NO and/or Low NO˺ NOx Calculated SO˺ Electrochemical Electrochemical 0 - 5000 ppm 0 - 1000 ppm 0 - 100.0 ppm 0 - 5000 ppm 0 - 5000 ppm 1 ppm 1 ppm 0.1 ppm 1 ppm 1 ppm ±5 ppm (0 - 100 ppm) ±5% rdg (101 - 5000ppm) ±5 ppm (0 - 100 ppm) ±5% rdg (101 - 1000ppm) ±1.5 ppm (0.0 - 40.0ppm) ±5% rdg (40.1 - 100.0ppm) ±5 ppm (0 - 100ppm) ±5% rdg (101 - 5000ppm) -20 to 1250 ̿C -10 to 100 ̿C ±1 ̿C ̝˟ʳˤ̇ Nj_¶ ʹˠ˟ˠ ǼŸ ˠˡˤ˟ ̿C) 0.1 ̿C 0.1 ̿C Ordering Information Model No. Description E6000 with O˺, CO, NO, SO˺, H˺S Gas Sensors Installed, Upgradeable to 6th Gas Sensor* E6000 with O˺, CO, NO, NO˺ , SO˺ Gas Sensors Installed, Upgradeable to 6th Gas Sensor*E6000-5DS E6000 with O˺, CO, NO, NO˺, CxHy(HC) Gas Sensors Installed, Upgradeable to 6th Gas Sensor*E6000-5DC E6000-5SH Probes & Hoses Standard: 12”, 300mm Probe, 1470̿F/800̿C max with 10’/3m Dual Hose Long: 30”, 750mm Probe, 1470̿F/800̿C max with 10’/3m Dual Hose Long & High Temp: 40”, 1m Probe, 2190̿F/1200̿C max, with 10’/3m Hose Hose Extensions: 10’/3m Length Available All E6000 Kits Include: ˒ Built-In Printer ˒ CO Dilution Auto-Range to 10% ˒ Draft & Differential Pressure ˒ Temperature Measurements ˒ Calculation for CO˺, Efficiency & Excess Air ˒ Rechargeable Batteries & AC Charger ˒ Gas Sampling Probe & Hoses ˒ Water Trap with Filter Cartridge ˒ Magnetic Rubber Holster ˒ 2000 Test Internal Memory ˒ PC Software & USB Cable ˒ Bluetooth Module (Internal) ˒ Operating Manual ˒ Calibration Certificate ˒ ABS Hard Plastic Carrying Case ˒ Android Smart Phone App CxHy (HC) Pellistor 0 - 5% 0.01% ±5% Full Scale Bulletin:E6000.2Ed.01/2017Information&designsubjecttochangeatmanufacture’sdiscretion Low SO˺ Electrochemical 0 - 100.0 ppm 0.1 ppm ±1.5 ppm (0.0 - 40.0ppm) ±5% rdg (40.1 - 100.0ppm) E6000-5SC E6000 with O˺, CO, NO, SO˺, CxHy(HC) Gas Sensors Installed, Upgradeable to 6th Gas Sensor* High Temperature Probe & Sintered Filter Availabled FFilter Aveeeereee ed vailable& Sinteered FFilter Avere *All Configurations Available With Low NO, Low NO˺, and/or Low SO˺ Sensors H˺S Electrochemical 0 - 500 ppm 0.1 ppm ±5 ppm (0.0 - 125.0ppm) ±4% rdg (125.1 - 500.0ppm) E6000-6DSH E6000-6DSC E6000 with O˺, CO, NO, NO˺, SO˺, H˺S Gas Sensors Installed* E6000 with O˺, CO, NO, NO˺, SO˺, CxHy(HC) Gas Sensors Installed*
  20. 20. Portable Industrial Flue Gas & Emissions Analyzer Complete Portable Emissions Analyzer with up to Nine Gas Sensors for Boiler, Engine, Furnace, and other Combustion Applications CO O˺ E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind NO E8500 PLUS Built-In Thermoelectric Chiller Up to 9 Total Gas Sensors MADE IN USA CO Dilution Auto-Range Automatic Condensate Drain Long Life Rechargeable Battery Upgraded Memory (2000 Tests) True NOx & Low NOx Measurements High Accuracy NDIR Sensors NO˺ SO˺ H˺S VOC CO˺ NEW Display Screen & Keypad NEW Software with Automatic Data Logging Direct CO˺ Measurement to 50% y 2000 Tests) ents creen & Keypad nt to 50% CxHy(HC) NEW Display Screen & Keypad Design with Easy Filter Replacement NEW REAL-TIME Software Package with Automatic Data Logging REA NEW PID VOC Sensor OptionNEW (NDIR) True SO˺ & Low SO˺ Measurements Sample Conditionniinng UUnnit For Looww NNOOx & SO2 Backlit Display with Zoom Function
  21. 21. E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind E8500 PLUS The updated “EGAS” software package includes the ability to save & graph data in real-time in the field with a laptop or in a laboratory with a PC. It also allows the user to automatically log data for an exact number of tests for a specified time period. Communications between the E8500 PLUS and a computer are established either by wireless Bluetooth communications or USB cable. A Bluetooth wireless adapter for a computer comes standard with each E8500 PLUS gas analyzer. Data from the “EGAS” software can be exported to other spreadsheet programs for more user flexibility to create detailed emissions reports. Real-Time Software with Data Logging EGAS Software The internal thermoelectric chiller efficiently and quickly removes the water vapor from the flue gas sample to prevent combustion gases from bubbling from the gas phase into the condensate. The built-in condensate drain pump automatically pumps the accumulated water out through the bottom of the unit for greater convenience. Built-In Thermoelectric Chiller with Auto Condensate Drain 40”(1m) & 60”(1.5m) High Temperature Probeshh Temperature Prob 40”(1m) & 600”(1 5m) Sintered Filter
  22. 22. E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind ϴϱϬϬ Wh^ ^ƉĞĐŝĮĐĂƟŽŶƐ The E8500 PLUS has a newly designed user interface that includes an easily accessible filter compartment for quick and simple inspection replacement of filters in the field. Easy Filter Replacement The E8500 PLUS can have a maximum of nine total gas sensors; up to six electrochemical type sensors, up to three NDIR type sensors, and an optional PID sensor for measuring VOC. Gas Sensors An internal pressure sensor allows the analyzer to measure both pressure and stack draft. With two pressure inputs, differential pressure can also be measured. Gas velocity can be measured using the differential pressure and an optional Pitot tube. Draft, Pressure, Velocity Parameter Sensor Range Res. Accuracy O CO CO NO NO Pressure/Draft Excess Air Gas Velocity Efficiency 2 x ppm=±4% up to 5000 ppm=±4% 1.00 - infinity Electrochemical up to 2000 ppm=±4% 2000 ppm=±10% NDIR Electrochemical up to 5000 up to 1000 ppm=±4% up to 500 ppm=±4% 14.0 - 212.0°F 32.0 - 1830°F 32.0 - 1830°F Calculated Calculated Calculated Auto Range CO NO Low NO Low NO SO CO CO C H H S VOC Tair Tgas 2 2 2 2 2 x y 2 'T 0 - 8000 ppm 1 ppm 300 ppm=±8 ppm 0.01% ±0.1% vol0 - 25%Electrochemical ±10% rdg.1 ppm0 - 20,000 ppmElectrochemical 0 - 15.00% 0.01% ±3% rdg. 0 - 5000 ppm 1 ppm 1 ppm 125 ppm=±5 ppm Electrochemical 0 - 1000 ppm 125 ppm=±5 ppm up to 100.0 ppm=±4% 0 - 100.0 ppm 0.1 ppmElectrochemical 50.0 ppm=±1.5 ppm Calculated 0 - 5000 ppm 1 ppm 0 - 5000 ppmElectrochemical 125 ppm=±5 ppm 1 ppm Calculated 0 - 99.9% 0.1% 0 - 50.0% 0 - 3.00% 0.1% 0.01% ±3% rdg. + 0.01% ±3% rdg. 20% NDIR NDIR Electrochemical 0 - 500 ppm 1 ppm 125 ppm=±5 ppm PID 0 - 200 ppm 1 ppm ±10 % rdg. + 1 ppm Calculated Pt100 -10 - 99.9°C 1°C 1°F ±2°C ±3°F Tc K 0 - 999.9°C 0.1°C ±3°C 0.1°F ±5°F 0 - 999.9°C 1°F 1°C Bridge ± 40.0 in H O 0.1 in H O ±1% rdg. 0.01 0 - 99.9 m/s 0 - 330 ft/s 0.1 m/s 0.1 ft/s 1 - 99.9% 0.1% 2 2 0 - 100.0 ppm 0.1 ppmElectrochemicalLow SO 0 - 100.0 ppm 0.1 ppmElectrochemical 2 up to 100.0 ppm=±4% 50.0 ppm=±1.5 ppm up to 100.0 ppm=±4% 50.0 ppm=±1.5 ppm The Sample Conditioning Unit is mounted directly at the sampling probe exit, where excess moisture rapidly condenses and separates from the gas sample. This minimizes contact of the gases with moisture, which could potentially affect NOx and SO2 measurements. Sample Conditioning Unit ±5% rdg. 20%
  23. 23. E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind E8500 PLUS E8500 PLUS Ordering Code Part # 8500P - Table A - Table B - Table C Table C - Sampling Probes and Hoses 12 12” (300mm) Probe, 1470°F (800°C) max, with 10’ (3m) Dual Hose 30 40 60 30” (750mm) Probe, 1470°F (800°C) max, with 10’ (3m) Dual Hose 40” (1m) Probe, 2190°F (1200°C) max, with 10’ (3m) Hose for High Temperature Combustion Applications 60” (1.5m) Probe, 2190°F (1200°C) max, with 10’ (3m) Hose for High Temperature Combustion Applications Table B - NDIR (non-dispersive infrared) Sensors ABC CO Sensor (0 - 50 %), CxHy Sensor (0 - 3 %), High CO Sensor (0 - 15 %)2 and 0 No NDIR sensors Standard E8500 PLUS Configuration (E8500P-OCN-0-12) Includes: - O2, CO, and NO Gas Sensors - Thermoelectric Chiller with Automatic Condensate Drain Pump - Rechargeable Battery Pack - 110-240VAC/50-60Hz Battery Charger - 12”/300mm Probe with 10’/3m Dual Hose - Stack Gas Air Temperature Measurements - Draft Differential Pressure Measurements - Calculated Values for Efficiency, Excess Air, CO % - Internal Memory (2,000 Tests) - Real-Time Software Package with Bluetooth Module - Wireless Bluetooth Communications - Protective Carrying Case - Calibration Certificate - Operations Manual 2 Weight: 11 lbs. (5 kg) Dimensions: 10x6x9.5” (26x15x24 cm) mp Bulletin:E8500PLUS.2Ed.01/2017Informationdesignsubjecttochangeatthemanufacturer’sdiscretion Table A - Electrochemical Sensors O C N D S H O Sensor (0 - 25 %) CO Sensor (0 - 8000 ppm) with Dilution Auto-Range up to 20,000 ppm NO Sensor (0 - 5000 ppm) NO Sensor (0 - 1000 ppm) SO Sensor (0 - 5000 ppm) H S Sensor (0 - 500 ppm) 2 2 2 2 V VOC Sensor (0 - 200 ppm)** *H S VOC sensors cannot concurrently be installed on one E8500 PLUS2 **Must include NDIR sensor option to include VOC sensor
  24. 24. Portable Industrial Flue Gas Emissions Analyzer Portable Emissions Analyzer with Temperature Controlled NOx Measurement for Boiler, Engine, Furnace, and other Combustion Applications E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind E8500 Cooled NOx Built-In Thermoelectric Cooler for NO Sensor Up to 9 Total Gas Sensors MADE IN USA CO Dilution Auto-Range Long Life Rechargeable Battery Upgraded Memory (2000 Tests) True NOx Low NOx Measurements NEW Display Screen Keypad NEW Software with Automatic Data Logging Direct CO˺ Measurement to 50% USAMADE IN UUS NEW Cooled NO Sensor to Optimize Accuracy of NOx Measurements NEW A Displays Records the Temperature at the Cooled NO Sensor DispDisp CO O˺ NO˺ SO˺ H˺S VOC CxHy CO˺(NDIR) NEW PID VOC Sensor Option NOx NO(Cooled)
  25. 25. E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind E8500 Cooled NOx The updated “EGAS” software package includes the ability to save graph data in real-time in the field with a laptop or in a laboratory with a PC. It also allows the user to automatically log data for an exact number of tests for a specified time period. Communications between the E8500 Cooled NOx and a computer are established either by wireless Bluetooth communications or USB cable. A Bluetooth wireless adapter for a computer comes standard with each E8500 Cooled NOx gas analyzer. Data from the “EGAS” software can be exported to other spreadsheet programs for more user flexibility to create detailed emissions reports. Real-Time Software with Data Logging EGAS Software The accuracy of the gas sensor for NO, the primary component of NOx, can be compromised when exposed to ambient temperatures above 86°F (30°C) and significantly more so above 104°F (40°C). To help prevent this temperature effect on the NO sensor, the E8500 Cooled NOx keeps the NO sensor cooled with an internal cooling system. The analyzer measures, displays, records the NO sensor temperature to make it easier to comply with US EPA conditional test methods such as CTM-030. Cooled NO Sensor for Optimal Accuracy Sintered Filter 40”(1m) 60”(1.5m) High Temperature Probes
  26. 26. E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind ϴϱϬϬ ŽŽůĞĚ EKdž ^ƉĞĐŝĮĐĂƟŽŶƐ The E8500 Cooled NOx has a newly designed user interface that includes an easily accessible filter compartment for quick and easy inspection replacement of filters in the field. Easy Filter Replacement The E8500 Cooled NOx can have a maximum of nine total gas sensors; up to six electrochemical type sensors, up to three NDIR type sensors, and an optional PID sensor for measuring VOC. Gas Sensors An internal pressure sensor allows the analyzer to measure both pressure and stack draft. With two pressure inputs, differential pressure can also be measured. Gas velocity can be measured using the differential pressure and an optional Pitot tube. Draft, Pressure, Velocity Parameter Sensor Range Res. Accuracy O CO CO NO NO Pressure/Draft Excess Air Gas Velocity Efficiency 2 x ppm=±4% up to 5000 ppm=±4% 1.00 - infinity Electrochemical up to 2000 ppm=±4% 2000 ppm=±10% NDIR Electrochemical up to 5000 up to 1000 ppm=±4% up to 500 ppm=±4% 14.0 - 212.0°F 32.0 - 1830°F 32.0 - 1830°F Calculated Calculated Calculated Auto Range CO NO Low NO Low NO SO CO CO C H H S VOC Tair Tgas 2 2 2 2 2 x y 2 'T 0 - 8000 ppm 1 ppm 300 ppm=±8 ppm 0.01% ±0.1% vol0 - 25%Electrochemical ±10% rdg.1 ppm0 - 20,000 ppmElectrochemical 0 - 15.00% 0.01% ±3% rdg. 0 - 5000 ppm 1 ppm 1 ppm 125 ppm=±5 ppm Electrochemical 0 - 1000 ppm 125 ppm=±5 ppm up to 100.0 ppm=±4% 0 - 100.0 ppm 0.1 ppmElectrochemical 50.0 ppm=±1.5 ppm Calculated 0 - 5000 ppm 1 ppm 0 - 5000 ppmElectrochemical 125 ppm=±5 ppm 1 ppm Calculated 0 - 99.9% 0.1% 0 - 50.0% 0 - 3.00% 0.1% 0.01% ±3% rdg. + 0.01% ±3% rdg. 20% NDIR NDIR Electrochemical 0 - 500 ppm 1 ppm 125 ppm=±5 ppm PID 0 - 200 ppm 1 ppm ±10 % rdg. + 1 ppm Calculated Pt100 -10 - 99.9°C 1°C 1°F ±2°C ±3°F Tc K 0 - 999.9°C 0.1°C ±3°C 0.1°F ±5°F 0 - 999.9°C 1°F 1°C Bridge ± 40.0 in H O 0.1 in H O ±1% rdg. 0.01 0 - 99.9 m/s 0 - 330 ft/s 0.1 m/s 0.1 ft/s 1 - 99.9% 0.1% 2 2 0 - 100.0 ppm 0.1 ppmElectrochemicalLow SO 0 - 100.0 ppm 0.1 ppmElectrochemical 2 up to 100.0 ppm=±4% 50.0 ppm=±1.5 ppm up to 100.0 ppm=±4% 50.0 ppm=±1.5 ppm The Sample Conditioning Unit is mounted directly at the sampling probe exit, where excess moisture rapidly condenses and separates from the gas sample. This minimizes contact of the gases with moisture, which could potentially affect NOx and SO2 measurements. Sample Conditioning Unit ±5% rdg. 20%
  27. 27. E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind E8500 Cooled NOx E8500 Cooled NOx Ordering Code Part # 8500CN - Table A - Table B - Table C Table C - Sampling Probes and Hoses 12 12” (300mm) Probe, 1470°F (800°C) max, with 10’ (3m) Dual Hose 30 40 60 30” (750mm) Probe, 1470°F (800°C) max, with 10’ (3m) Dual Hose 40” (1m) Probe, 2190°F (1200°C) max, with 10’ (3m) Hose for High Temperature Combustion Applications 60” (1.5m) Probe, 2190°F (1200°C) max, with 10’ (3m) Hose for High Temperature Combustion Applications Table B - NDIR (non-dispersive infrared) Sensors ABC CO Sensor (0 - 50 %), CxHy Sensor (0 - 3 %), High CO Sensor (0 - 15 %)2 and 0 No NDIR sensors Standard E8500 Cooled NOx Configuration (E8500CN-OCN-0-12) Includes: - - - Rechargeable Battery Pack - 110-240VAC/50-60Hz Battery Charger - 12”/300mm Probe with 10’/3m Dual Hose - Stack Gas Air Temperature Measurements - Draft Differential Pressure Measurements - Calculated Values for Efficiency, Excess Air, CO % - Internal Memory (2,000 Tests) - Real-Time Software Package with Bluetooth Module - Wireless Bluetooth Communications - Protective Carrying Case - Calibration Certificate - 2 Weight: 11 lbs. (5 kg) Dimensions: 10x6x9.5” (26x15x24 cm) T Bulletin:E8500CooledNOx.1Ed.03/2017Informationdesignsubjecttochangeatthemanufacturer’sdiscretion Table A - Electrochemical Sensors O C N D S H O Sensor (0 - 25 %) CO Sensor (0 - 8000 ppm) with Dilution Auto-Range up to 20,000 ppm NO Sensor (0 - 5000 ppm) NO Sensor (0 - 1000 ppm) SO Sensor (0 - 5000 ppm) H S Sensor (0 - 500 ppm) 2 2 2 2 V VOC Sensor (0 - 200 ppm)** *H S VOC sensors cannot concurrently be installed on one E8500 Cooled NOx2 **Must include NDIR sensor option to include VOC sensor - - NL Low NO Sensor (0 - 100.0 ppm) DL Low NO Sensor (0 - 100.0 ppm)2 - NO Sensor Temperature Measurement Operations Manual External Water Trap with Filter Thermoelectric Cooler for NO Sensor O2, CO, and NO Gas Sensors Sample Conditioning Unit
  28. 28. Portable Industrial Flue Gas Emissions Analyzer Transportable Emissions Analyzer for Boiler, Engine, Furnace, Kiln, and other Combustion Applications CO O˺ E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind NO E9000 Built-In Thermoelectric Chiller Up to 9 Total Gas Sensors CO Dilution Auto-Range Automatic Condensate Drain Pre-Calibrated Gas Sensors Upgraded Memory (16,000 Tests) True NOx Low NOx Measurements High Accuracy NDIR Sensors Including CO˺ Sensor to 50% NO˺ SO˺ H˺S Low NOx CO˺ Color Graphic Display Software with Automatic Data Logging Built-In Printer CxHy(HC) Heated Probe Head Sample HoseHea Software Package with Automatic Data Logging Soft (NDIR) Android App to Monitor Save Data lt-In Thermoelectric Chiller ge tic Condensate Drain rs emory (16,000 Tests) ments s % isplay Software US EPA CTM-030 CTM-034 Compliant Customize to Meet Your Em issio ns Monitoring Requirem ents Heavy Duty Case
  29. 29. E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind E9000 Specifications Heated Sample Hose Probe Head The E9000 has an optional heated probe head and flexible heated sample line. This feature maintains the sample gas at a temperature higher than the dew point to prevent condensation from occurring before the stack gas reaches the internal thermoelectric chiller. The water vapor condenses very rapidly at the chiller so the gases do not have ample opportunity time to dissolve into the condensate. This sample conditioning system maintains the integrity of the gas composition especially for the most water soluble gases such as NO˺ and SO˺. The large multi-color graphic display screen includes a zoom function. The capacitive touch sensing keypad guides the operator through the user friendly menus on the display screen. The measured calculated parameters on the display screen can be fully customized as the operator requires. The internal printer is included with each E9000 and prints on a special non-fading polymer paper so it can still be easily read even when exposed to water, heat, or light. As with the display screen, the parameters on the print-out can be customized by each operator. Each E9000 includes an internal high efficiency Peltier thermoelectric chiller with a built-in condensate drain pump that automatically pumps the accumulated water out through the bottom of the unit for greater convenience. Along with the optional heated sample hose probe head, this sample conditioning system allows for longer test periods while maximizing the integrity and composition of the sampled stack gas so the gases measured by the analyzer are representative of the actual stack/flue gases. Superior Sample Conditioning for Semi-Continuous Use Display Screen Keypad Built-In Printer
  30. 30. E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind E9000 Specifications Parameter Sensor Range Res. Accuracy O CO CO NO NO 2 x ppm=±4% up to 5000 ppm=±4% Electrochemical up to 2000 ppm=±4% 2000 ppm=±10% NDIR Electrochemical up to 5000 up to 1000 ppm=±4% up to 500 ppm=±4% Auto Range CO NO Low NO Low NO SO CO CO C H H S 2 2 2 2 2 x y 2 0 - 8000 ppm 1 ppm 200 ppm=±5 ppm 0.1% ±0.1% vol0 - 25%Electrochemical ±10% rdg.0.01%0 - 10.00%Electrochemical 0 - 15.00% 0.01% ±3% rdg. 0 - 5000 ppm 1 ppm 1 ppm 125 ppm=±5 ppm Electrochemical 0 - 1000 ppm 125 ppm=±5 ppm up to 100.0 ppm=±4% 0 - 100.0 ppm 0.1 ppmElectrochemical 50.0 ppm=±1.5 ppm Calculated 0 - 5000 ppm 1 ppm 0 - 5000 ppmElectrochemical 125 ppm=±5 ppm 1 ppm Calculated 0 - 99.9% 0.1% 0 - 50.0% 0 - 50,000 ppm 0.1% 1 ppm NDIR NDIR Electrochemical 0 - 500 ppm 0.1 ppm 125 ppm=±5 ppm Pellistor 0 - 5.00% 0.01% ±5 % Full Scale 0 - 100.0 ppm 0.1 ppmElectrochemicalLow SO 0 - 100.0 ppm 0.1 ppmElectrochemical 2 up to 100.0 ppm=±4% 50.0 ppm=±1.5 ppm up to 100.0 ppm=±4% 50.0 ppm=±1.5 ppm C Hx y up to 50,000 ppm=±2% 1000 ppm=±50 ppm up to 50%=±5% rdg. 8%=±3% rdg.
  31. 31. E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind E9000 Table C - Sampling Probes and Hoses 12 12” (300mm) Probe, 1470°F (800°C) max, with 10’ (3m) Dual Hose 30 40 60 30” (750mm) Probe, 1470°F (800°C) max, with 10’ (3m) Dual Hose 40” (1m) Probe, 2190°F (1200°C) max, with 10’ (3m) Hose for High Temperature Combustion Applications 60” (1.5m) Probe, 2190°F (1200°C) max, with 10’ (3m) Hose for High Temperature Combustion Applications Table B - NDIR (non-dispersive infrared) Sensors IR CO Sensor (0 - 50 %), CxHy Sensor (0 - 5 %), High CO Sensor (0 - 15 %)2 and 0 No NDIR sensors Standard E9000 Configuration (E9000-OCN-0-12) Includes: - O2, CO, and NO Gas Sensors, Upgradeable to 9 Gas Sensors Total - Thermoelectric Chiller with Automatic Condensate Drain Pump - Rechargeable Battery Pack - 110-240VAC/50-60Hz Battery Charger - 12”/300mm Probe with 10’/3m Dual Hose - Stack Gas Air Temperature Measurements - Draft Differential Pressure Measurements - Calculated Values for Efficiency, Excess Air, CO % - Internal Memory (16,000 Tests) - Software Package with USB Bluetooth Interface - Wireless Bluetooth Communications - Heavy Duty Aluminum Carrying Case - Calibration Certificate - Operations Manual 2 Weight: 29 lbs. (13 kg) Dimensions: 20x14x8” (50x36x20 cm) -12) Includeses: Sensors Totalal Pump Bulletin:E9000.1Ed.6/2016Informationdesignsubjecttochangeatthemanufacturer’sdiscretion E9000 Ordering Code Part # 9000 - Table A - Table B - Table C Table A - Electrochemical Sensors (Maximum of Six) O C N D S H O Sensor (0 - 25 %) CO Sensor (0 - 8000 ppm) with Dilution Auto-Range up to 10% NO Sensor (0 - 5000 ppm) NO Sensor (0 - 1000 ppm) SO Sensor (0 - 5000 ppm) H S Sensor (0 - 500 ppm) 2 2 2 2 NL Low NO Sensor (0 - 100.0 ppm) DL Low NO Sensor (0 - 100.0 ppm) SL Low SO Sensor (0 - 100.0 ppm)2 2 12” (300mm) Probe, 1470°F (800°C) max, with 10’ (3m) Heated Sample Hose Probe Head 12H 40” (1m) Probe, 2190°F (1200°C) max, with 10’ (3m) Heated Sample Hose Probe Head 40H SINT1 Sintered Filter with Half Shield for Probe Tip ( ) p
  32. 32. Application Notes Emissions Monitoring E Instruments is Proud to Offer A Wide Variety of In-Depth Application Notes to its Customers Such As: MARPOL ANNEX VI Compliance Using a Portable Emissions Analyzer Application Note # IA-14-0701 Flexibility Versatility of a Portable Emissions AnalyzerApplication Note # IA-13-0501 Mining Using Portable Emissions Analyzers for Optimizing the Performance of a Cogeneration Plant Application Note # IA-13-0801 Cogeneration Forklifts Marine Power Generation Engines Industrial Boilers For a Complete List of Our Application Notes Please Visit Our Website at www.E-Inst.com Refineries Cement Incinerators
  33. 33. Application Notes Combustion Analysis E Instruments is Proud to Offer A Wide Variety of In-Depth Application Notes to its Customers Such As: Why Use NOx Filters on CO Sensors?Application Note # HV-16-0915 The Importance of Combustible Gas Leak DetectionApplication Note # HV-13-0516 Boilers Measuring Combustion Efficiency on Atmospheric Boilers Furnaces Application Note # HV-13-0717 Technical Schools Burners For a Complete List of Our Application Notes Please Visit Our Website at www.E-Inst.com Furnaces Heaters Weatherization Research Development Energy Auditing Controls Building Inspection Facilities
  34. 34. Gas Sampling Probes Accessories 12(300mm) Standard Probe (gas draft), 1470F(800C) max, with 10'(3m) dual hose 30(750mm) Probe (gas draft), 1470F(800C) max, with 10'(3m) dual hose Sintered Filter with Half-Shield for End of Probe (compatible with 40 60 Probes only) for High Dust, Particle, Ash Applications 36 (900mm) Pitot Tube for Measurements Calculations of: Standard Probes Sintered Filter Pitot Tube ˒ Stack/Flue Gas Velocity ˒ Coal Fired Boilers ˒ Cement Kilns ˒ Volumetric Flow Rate ˒ Mass Emissions ˒ Steel Furnaces ˒ Incinerators ˒ Boilers ˒ Burners ˒ Heaters ˒ Engines Applications: Applications: 40 (1m) Probe, 2190F (1200C) max, with 10' (3m) Hose 60 (1.5m) Probe, 2190F (1200C) max, with 10' (3m) Hose Longer High Temperature Probes ˒ Cement ˒ Power Plants obes ˒ Steel ˒ Glass Applications: * Customized Probes available up to 100” (2.5m) in length available upon request Sample Conditioning Unit ˒ High Moisture Flue Gases ˒ ĵŸɠ ŗŷɮ ˓ ĵŸɠ Ǣŷ˺ Measurements Applications: Removes moisture at probe handle to maintain the integrity of the sampled flue gas. Available with all gas analyzers.
  35. 35. Built With Quality In Mind ‡ Automobiles ‡ Forklifts ‡ Trucks ‡ Buses ‡ Burnishers ‡ Loaders ‡ Excavators ‡ Tractors ‡ Motorcycles Applications Relevant Markets ‡ Material Handling ‡ Automotive Maintenance ‡ Transpotation Shipping ‡ Fleet Maintenance ‡ Mining ‡ Fuel Additives ‡ Engine Catalysts ‡ Construction ‡ Combustion Research Automotive Emissions Product Line
  36. 36. Automotive Emissions Analyzers F900 O2 CO F5000 O2, CO, NO, CxHy 7899 Hydrocarbon Detector
  37. 37. O2Robust Fast Reliable Accurate E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind N Forklift Small Engine Exhaust Gas Analyzer Pre-Compliance VerificationPre- CO Safety TestingCO S Engine Tuning MaintenanceEngi CO Traceable Calibration Certificate Optional Wireless Bluetooth™ Printer Oxygen (O2)Measurement Internal Memory (2,000 Tests) Measure CO Up to 50,000 ppm (5%) Sampling Probe S-Type Exhaust Fitting Real-Time Data Logging Software g yp h Ideal For: Automatic Data Saving Feature Protective Magnetic Boot MADE IN USA
  38. 38. Built with Quality in Mind Ordering Information Model No. Description F900 F900-P Base Kit = CO Sensor, 2,000 Internal Test Memory, PC Software, Bluetooth™, Exhaust Sampling Probe Base Kit w/ Printer = CO Sensor, 2,000 Internal Test Memory, PC Software, Bluetooth™, Exhaust Sampling Probe + Wireless Bluetooth™ Printer E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com ˒ CO Sensor (0 to 50,000 ppm, 5%) ˒ Option for O2 Sensor ˒ 2,000 Test Internal Memory ˒ Bluetooth Connectivity ˒ Rechargeable Battery AC Charger ˒ ˠˡˇ Gas Sampling Probe Hose ˒ ŷƼǼÞŸŘ ¯ŸNj Ǣ˚ǻɴƼs ƻNjŸEs ®ÞǼǼÞŘض ˒ ŷƼǼÞŸŘ ¯ŸNj ®ĶsɮÞEĶs ƻNjŸEs ǻÞƼ ˒ Water Trap with Filter Cartridge ˒ Magnetic Rubber Holster ˒ PC Software USB Cable ˒ Operating Manual ˒ Calibration Certification ˒ Vinyl Carrying Case ˒ ŷƼǼÞŸŘ ¯ŸNj ɟÞNjsĶsǣǣ Bluetooth™ Printer All F900 Kits Include: S-Type Probe Fitting w/ Exhaust Clamp Flexible Tip Optional Wireless Bluetooth™ Printer NEW!! PC Software Wireless Bluetooth High Range CO Sensor (0 - 50,000 ppm, 5%) Internal Memory Automatic Data Saving Gas Sampling Probe Magnetic Boot Applications Parameter Sensor ResolutionRange Accuracy ŷ˺ CO Electrochemical Electrochemical 0 - 25% 0 - 50,000 ppm (0 - 5 %) ˟ʳˠ̇ ˠ ƼƼŎ ±0.2% vol ±8 ppm 300 ppm ±4% rdg up to 4000 ppm ̝ˠ˟̇ Nj_¶ ̤ˣ˟˟˟ ƼƼŎ Technical Specifications Hands Free Operation Durable Design Forklifts Propane Burnishers Polishers Other Small Engines Propane Grinders Bulletin:F900.3Ed.01/2017Informationdesignsubjecttochangeatmanufacture’sdiscretion nical Specificat PC Software with Real-Time Automatic Data Logging Save, Graph, Export Data Wirelessly via Bluetooth S-Type P w/ Exhaust Clamp Flexible Tip sly
  39. 39. E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com Automotive Forklift Exhaust Gas Analyzer Pre-Compliance VerificationPre- Vehicle DiagnosticsVehi Engine Tuning MaintenanceEngi Applications: Built with Quality in Mind Flexible Exhaust Probe Tip Sampling Probe with S-Type Exhaust Fitting Real-Time Data Logging Software Wireless Bluetooth™ Printer High Accuracy NDIR Sensors: CO, CO2, HC For Propane, Diesel, LPG, CNG, Gasoline Engines CO HC CO2 NOxO2 AFR Lambda (ʭ)
  40. 40. Built with Quality in Mind E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com ˒ CO2 Sensor ˒ CO Sensor ˒ HC Sensor ˒ O2 Sensor ˒ NO/NOx Sensor ˒ Internal Memory (2000 Tests) ˒ Bluetooth Connectivity ˒ Rechargeable Battery Charger ˒ ˠˡˇˀˢ˟˟ŎŎ Sampling Probe ˠ˟˅ˀˢŎ Ǣ ŎƼĶÞض ËŸǣs ˒ S-Type Exhaust Fitting w/ Clamp ˒ Sample Conditioning Unit (SCU) For Condensation Removal ˒ PC Software USB Cable ˒ Operating Manual ˒ Calibration Certificate ˒ ŷƼǼÞŸŘ ¯ŸNj ɟÞNjsĶsǣǣ Bluetooth™ Printer ˒ ŷƼǼÞŸŘ ¯ŸNj ®ĶsɮÞEĶs Probe Attachment ˒ ŷƼǼÞŸŘ ¯ŸNj ƻNjŸǼsOǼÞɚs N NjNjɴÞض N ǣs F5000-5GAS Includes: Optional Wireless Bluetooth™ Printer Applications Bulletin:F5000.3Ed.01/2017Informationdesignsubjecttochangeatmanufacture’sdiscretion ndBuilt with Quality in Min Flexible Probe Tip PC Software with Real-Time Automatic Data Logging Technical SpecificationsTe Parameter Sensor ResolutionRange Accuracy CO NDIR ˟˚ˠˤ ̇ ˟ʳ˟ˠ ̇ ˟ʳ˟ˡ̇ ̝ˢ̇ Nj_¶ʳ NDIR ˟˚ˡ˟ ̇ ˟ʳˠ ̇ ˟ʳˠ̇ ̝ˢ̇ Nj_¶ʳNŷ˺ HC NDIR ˟ ˚ ˠ˟ʰ˟˟˟ ƼƼŎ ˠ ƼƼŎ ŷ˺ Electrochemical ˟ ˚ ˡˤ̇ ˟ʳˠ̇ ̝˟ʳˠ̇ ɚŸĶ NO/NOx Electrochemical ˟ ˚ ˤʰ˟˟˟ ƼƼŎ ˠ ƼƼŎ ̣ˠˡˤ ƼƼŎ̠̝ˤ ƼƼŎ ȖƼ ǼŸ ˤʰ˟˟˟ ƼƼŎ̠̝ˣ̇ Light Weight, Portable, Durable Printed Digital Emissions Reports Rechargeable, Long Life Battery Vehicles Trucks Buses Forklifts MADE IN USA Swivel Handle For Easy Operation Transport S-Type Probe Fitting Exhaust Clamp ̝ˢ̇ Nj_¶ʳ ʹˢ˟ˠ˚ˣʰ˟˟˟ ƼƼŎʺ ̝˧ ƼƼŎ ʹ˟˚ˢ˟˟ ƼƼŎʺ ̝ˤ̇ Nj_¶ʳ ʹˣʰ˟˟ˠ˚ˠ˟ʰ˟˟˟ ƼƼŎʺ
  41. 41. Economical Accurate Combustible Hydrocarbon Gas Detector for Automotive, Small Engines, and Forklifts Hydrocarbon Gas Detector Model 7899 Propane Propane Propane 2 0.0 - 5,500 ppm
  42. 42. Automotive Emissions Sampling Probes Accessories 12(300mm) Exhaust Gas Sampling Probe with 10'(3m) hose Standard Probe 12(300mm) Exhaust Gas Sampling Probe with S-Type Fitting, Exhaust Clamp, 10'(3m) hose Standard Probe with S-Type Fitting 12(300mm) Exhaust Gas Sampling Probe with Sample Conditioning Unit (SCU), S-Type Fitting, Exhaust Clamp, 10'(3m) hose Automotive Probe Flexible Extension for Probes Installed with an S-Type Fitting Flexible Tip Extension Wireless Bluetooth Printer Sampling Prob lamp, 10'(3m) hose Probes Installed with an S-Type Fitting Wireless Bluetooth Printer for On-Site Emissions Reports (Comes With SCU)
  43. 43. Built With Quality In Mind Product Line Markets Applications ‡ Architects Building Developers ‡ Research Development ‡ Manufacturing Facilities ‡ Research Laboratories ‡ Greenhouse Buildings ‡ Hospitals Medical ‡ Building Inspectors ‡ LEED Certification ‡ Industrial Hygiene ‡ Building Hygiene ‡ Energy Auditing ‡ Weatherization ‡ VOC Testing ‡ Warehouses ‡ Universities ‡ Incubators ‡ Airports IAQ
  44. 44. Indoor Air Quality Monitors AQ PRO AQ Incuba AQ VOC AQ Comfort AQ Expert NONNNNNNNOOOOOOO CH O2 CO2CCCCCOOOOOOOO22222222 SSSSSSS2H COCCCCCCCCCOOOOOOOO % RHRRRRRRHHHHHHHH%%%% RRRRRRRR NO2NNNNNNNOOOOOOO222222222 SO2 O2 VOC O3
  45. 45. Protective Magnetic Rubber Boot Handheld Indoor Air Quality Monitor PC Software USB Cable E Instruments International www.E-Inst.com P: 215-750-1212 Wireless Communications with Computer Remote Printer Light Weight, Durable, Handheld Design F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 CO2 The Latest in Indoor Air Quality Monitoring Real-Time Data-Logging for IAQ Analysis in Homes, Schools, Offices, and much more Real-Time Data-Logging for Graphs, Data Review, IAQ Reports “Built with Quality in Mind” Temp. % RH Optional Handheld Probe Temp. Differential Optional Wireless Printer AQ ComfortAQ Comfort CO Add Safety- Long Lasting Rechargeable Battery Easy to Use Menu System Large Internal Memory (2000) Innovative IAQ Tool for HVAC Professionals REAL-TIME Continuous Data-Logging Provide your own Comfort Audit ™ Active Internal Sampling Pump Compact Handheld Unit Dew Point Differential Pressure Wet Bulb Accessories: MADE IN USA
  46. 46. P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 E Instruments International www.E-Inst.com Applications Distributed By: Bulletin:AQCOMFORT.1Ed.10/2016Informationdesignsubjecttochangeatthemanufacture’sdiscretion.’ (Optional) AQ Gas Real-time Datalogging Software ® CO % RH CO2 ALL AQ Comfort Kits Include: Ɣ Continuous Active Internal Sampling Pump Ɣ Differential Pressure Ɣ Operating Manual Ɣ Long Lasting Battery AC Charger Ɣ Factory Calibration Certificate Ɣ Differential Temperature AQ ComfortAAQQQ ComfortComfortComfort Temp ¨P Temp. CO Relative Humidity Ambient CO2 Temperature Type K T1 Differential Pressure Specifications Parameter Sensor Range Res. Accuracy 0 - 200 ppm 0.1 ppm ± 1% rdg. ± 0.2 ppmElectrochemical NDIR 0 - 5,000 ppm 1 ppm 0.1°C/F Tc K (0 - 1100°C) 0.1%TFC Bridge ± 8.0 inH O ± 1% rdg.2 (±20.0 mbar) (0.25 mbar) (-40 - 125°C) Electomagnetic Compatibility EN 61326-1, Portable Equipment Temperature CO Features AQ Comfort ORDERING CODE AQ Comfort Kit CO2 Bluetooth AmbientTemp %RH, Wet Bulb Dew Point Carrying Case Ŷ Kit-1 Kit-2 Ŷ Ŷ Ŷ Ŷ Ŷ Ŷ Ŷ Ŷ Ŷ Ŷ Ŷ Ŷ Ŷ Ŷ Ŷ Ŷ Ŷ Kit-3 Kit-4 Internal Memory (2000) PC Software Kit ŶŶ -40 - 257°F Pt100 20.1 inH O 5°F (3°C) or 2% of rdg1°C/F 0 - 2000°F 5 - 95% ± 0.4°C (0 - 60°C) ± 2% RH ± 2% rdg. ± 10 ppm
  47. 47. PC Software USB Included Long Lasting Rechargeable Battery Barometric Air Pressure Protective Magnetic Rubber Boot Large Internal Memory (2000) Handheld Indoor Air Quality Monitor E Instruments International www.E-Inst.com P: 215-750-1212 Wireless Communications with Computer Remote Printer Light Weight, Durable, Handheld Design F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 CO CO 2 Customize UP to 3 Gases The Latest in Indoor Air Quality Monitoring Real-Time Data-Logging for IAQ Analysis in Hospitals, Universities, Labs, Airports, and more Graphs, Data Review, IAQ reports AQ PRO REAL-TIME Continuous Data-Logging Active Internal Sampling Pump “Built with Quality in Mind” H S2 NO2 SO2 Temp AAQQQ OPROPRO % RH Compact Handheld Unit O2 Optional Handheld Probe Barometric Pressure Formaldehyde NO Optional Wireless Printer MADE IN USA Real-Time Data-Logging for attery oot a-LLoooogging mp (Multiple Parameters - Up to 6 Total)
  48. 48. P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 E Instruments International www.E-Inst.com AQ PROAQ PRO Relative Humidity Temp. Ambient Barometric Pressure Pressure Temperature Type K T1 Differential Specifications Parameter Sensor Range Res. Accuracy Pt100 -40 - 257°F 0.1°C/F ± 0.4°C (0 - 60°C) Solid State Tc K 0 - 2000°F 1°C/F ± 2% of rdg (0 - 1100°C) 5 - 95% RH 0.1% RH ± 2% RHTFC Bridge ± 8.0 inH O 0.1 inH O ±1% of rdg.2 2 Distributed By: NO2 SO2 O2 CO H2S % RH CO2 CH O2 Bulletin:AQPRO.5Ed.01/2017Informationdesignsubjecttochangeatthemanufacture’sdiscretion.’ AQ Gas Real-Time Datalogging Software 260 - 1260 mbar 1 mbar ± 2 mbar NNNNNNNOOOOOOOO222222222 OOOOOOOOO2222222 CCCCCCCCOOOOOOOO SSSSSSOOOOOO22222SS %%%% RRRRRRRHHHHHHH%%%% HHHHHHH2222222SSSSS CCCCHHHHHHH OOOOOOOO22222 OO CCCCCOOOOOOO2222222 (±20.0 mbar) (0.25 mbar) (-40 - 125°C) Electomagnetic Compatibility EN 61326-1, Portable Equipment Operating Manual Quick Reference Guide ALL AQ PRO Kits Include: Temperature, % Relative Humidity Continuous Active Internal Sampling Pump Differential Pressure Long Lasting Battery AC Charger Factory Calibration Certificate AQ PRO ORDERING CODE Barometric Pressure PC Software USB Cable Bluetooth Connectivity Protective Carrying Case Select UP to ANY 3* Gases Below: Part #: PRO - ___ - ___ - ___ Optional Accessories Wireless Bluetooth™ Printer ories Example: Part #: PRO - C2 - C - H = CO2, CO, H2S Parameter Sensor Range Res. Accuracy O - Oxygen (O ) EC 0 - 25% 0.1 % ± 0.1% vol rdg.2 C2 - Carbon Dioxide (CO ) NDIR 0 - 5,000 ppm 1 ppm ± 2% of rdg. ± 10 ppm2 1 EC 0 - 20 ppmN - Nitrogen Dioxide (NO )2 EC 0 - 250 ppm 0.1 ppm ± 4% of rdg. ± 0.5 ppmX - Nitric Oxide (NO) 2 EC 0 - 20 ppm 0.1 ppm ± 4% of rdg. ± 0.5 ppm- Sulfur Dioxide (SO )2 1 H - Hydrogen Sulfide (H S) 0 - 100 ppm 1 ppm2 ±4% of rdg. ± 0.5 ppm C - Carbon Monoxide (CO) 0 - 200 ppm 0.1 ppm ± 4% of rdg. ± 0.5 ppm ® REAL-TIME Continuous Data-Logging F 0 - 10 ppm- Formaldehyde (CH O) ± 5% of rdg. ± 50 ppb (0 - 10,000 ppb) (EE900P) (E85AACSF13) Pitot Tube (BB610032) for Air Velocity Sampling Probe 0 - 300 ft/sec 1 ft/secAir Velocity Calculated ElectrochemicalOther Ranges are Available Upon Request Accuracy Based on Laboratory Conditions2.1. 3. This sensor may have interference from H2 , CO, H2S and other reducing gases such as alcohols4. 2,5 2,5 2,5 2,5 2,5 2,5 2,5 EC EC 1 3,4 EC 1 1 1 Maximum of TWO (2) Electrochemical (EC) Sensors Per Unit*5. (AQMET) Moisture Exchange Tube for Calibration ± 4% of rdg. ± 0.5 ppm0.1 ppm 1 ppb
  49. 49. Portable Handheld VOC Monitor E Instruments International www.E-Inst.com P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 AQ VOC “Built with Quality in Mind” AAQQQ CVOCVOC Accurate VOC Monitoring Real-Time Data-Logging for Air Quality Analysis in Industrial Safety, Environmental, Laboratories and other IAQ Applications Wireless Communications with Computer Remote Printer Light Weight, Durable, Handheld Design Real-time Data-Logging Software for Graphs, Data Review, IAQ reports VOC Formaldehyde CO CO 2 H S2 NO2 SO2 Temp % RH O2 Barometric Pressure NO REAL-TIME Continuous Data-Logging Active Internal Sampling Pump Large Internal Memory (2000) PC Software USB Included Long Lasting Rechargeable Battery Barometric Air Pressure Protective Magnetic Rubber Boot Optional Wireless Printer Optional Handheld Probe Dynamic PID VOC Sensor Technology VOC in ppb/μg/m³ or ppm/mg/m³ UPGRADEABLE: (Add UP TO 2 More Gas Sensors) 0 - 20,000 PPB 0 - 200 PPM MADE IN USA a-Logging mp ) ttery ot m/mg/m³ ensors)
  50. 50. EC P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 E Instruments International www.E-Inst.com AQ VOCAQ VOC Specifications Parameter Sensor Range Res. Accuracy Relative Humidity 5 - 95% RHTFC Distributed By: NO2 SO2 O2 CO H2S % RH Bulletin:AQPRO.2Ed.01/2017Informationdesignsubjecttochangeatthemanufacture’sdiscretion.’ AQ Gas Real-Time Datalogging Software SSSSSOOOOO222222 ® Barometric Pressure Solid State 260 - 1260 mbar 1 mbar NNNNNNNOOOOOOOO22222222 SS OOOOOOOOO2222222 CCCCCCCCOOOOOOOO %%%% RRRRRRRHHHHHHHH% HHHHHHH222222222SSSS CH O2 CCCCHHHHHH OOOOOOO22222 OO CO2CCCCCOOOOOO2222222 Temp. Ambient -40 - 257°F (-40 - 125°C) Electomagnetic Compatibility EN 61326-1, Portable Equipment Optional Accessories Wireless Bluetooth™ Printer Electrochemical EC 0 - 20 ppm- Sulfur Dioxide (SO ) EC ±4% of rdg. ± 0.5 ppmN - Nitrogen Dioxide (NO )2 X - Nitric Oxide (NO) EC 1 ppbF - Formaldehyde (CH O)2 ± 5% od rdg. ± 50 ppb 2 Other Ranges are Available Upon Request H - Hydrogen Sulfide (H S) EC 0 - 100 ppm 1 ppm2 ± 4% of rdg. ± 0.5 ppm Accuracy Based on Laboratory Conditions C - Carbon Monoxide (CO) EC 0 - 200 ppm 0.1 ppm ± 4% of rdg. ± 0.5 ppm Optional Gas Sensor Upgrades (Choose UPTo ANY 2) S - Carbon Dioxide (CO ) NDIR 0 - 5,000 ppm 1 ppm ± 2% of rdg. ± 10 ppm O - Oxygen (O ) EC 0 - 25%2 2C2 sories Sampling Probe (E85AACSF13)(EE900P) VOC Select Your VOC Range: Parameter Sensor Range (0 - 46,000 μg/m )3V1- PID 0 - 20,000 ppbLow Range VOC V2- PID 0 - 200 ppmHigh Range VOC (0 - 460 mg/m )3 ALL AQ VOC Kits Include: AQ VOC ORDERING CODE Part #: VOC- ___ - ___ - ___ Example: Part #: VOC - 1 - F - C2 = 2Low Range VOC, CH O, CO Operating Manual Quick Reference Guide Temperature, % Relative Humidity Continuous Active Internal Sampling Pump Long Lasting Battery AC Charger Factory Calibration Certificate Barometric Pressure PC Software USB Cable Bluetooth Connectivity Protective Carrying Case REAL-TIME Continuous Data-Logging 2 (0 - 46,000 μg/m )3 (1 μg/m )3 PID 0 - 20,000 ppb 1 ppb ±10 % of rdg. ± 20 ppb (1 mg/m ) PID 0 - 200 ppm 1 ppm ±10 % of rdg. ± 2 ppm (0 - 460 mg/m ) 3 Low Range VOC High Range VOC Pt100 ± 2% RH OR 3 Differential Pressure Bridge ±8.0 in H O 0.1 inH O ±1% of rdg.2 2 (±20 mbar) (0.25 mbar) Air Velocity 0 - 300 ft/secCalculated Pitot Tube (BB610032) for Air Velocity 1 1 2 2 2 2 2 2 2 2. 3,4 1 1 1 1 1. 3. 4. This sensor may have interference from H2 , CO, H2S and other reducing gases such as alcohols (AQ CAL-ZF) Zero Filter for Calibration (AQMET) Moisture Exchange Tube for Calibration y Conditions f Zero Filter for ation ± 2 mbar ± 0.4°C (0 - 60°C)0.1°C/F 0.1% RH 1 ft/sec 0 - 10,000 ppb 0 - 20 ppm 0.1% ± 0.1% vol rdg. 0 - 250 ppm 0.1 ppm 0.1 ppm 0.1 ppm ± 4% of rdg. ± 0.5 ppm ± 4% of rdg. ± 0.5 ppm
  51. 51. CO˺ Incubator Monitor The Latest in Incubator Monitoring Real-Time Data-Logging for Air Quality Analysis for Incubators E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind AQ INCUBA Relative Humidity Temperature CO2 Measurement Ranges of: (0 - 5%, 0 - 10%, 0 - 20%) MADE IN USA Active Internal Sampling Pump Long Lasting Rechargeable Battery Barometric Pressure CO˺ User Friendly Interface REAL-TIME Data-Logging Large Internal Memory (2000) Real-Time Data-Logging for Graphs, Data Review, IAQ Reports ReaeaRea Wireless Communications with Computer Remote Printer Wire Light Weight, Durable, Hand-Held Design Lig Accessories: Real-Time PC Software Protective Magnetic Hands-Free Boot Optional Wireless Printer Optional Temperature Probe Temp. Fast Reliable Accurate Samplililing Pump ttery etric Pressure ce E Data-Logging 000) ess CoCommunicationns wiitttttttthn ommp t oot %RH
  52. 52. P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 E Instruments International www.E-Inst.com Applications Bulletin:AQINCUBA.1Ed.04/2017Informationdesignsubjecttochangeatthemanufacture’sdiscretion.’ AQ Gas Real-time Datalogging Software ® AQ INCUBAAQ INCUBA % RH CO2 Temp P. Bar O2 Ambient CO2 Temperature Type K T1 Specifications Parameter Sensor Range Res. Accuracy NDIR 0 - 5% 0.1°C/F Tc K (0 - 1100°C) (-40 - 125°C) Electomagnetic Compatibility EN 61326-1, Portable Equipment Temperature -40 - 257°F Pt100 5°F (3°C) or 2% of rdg1°C/F 0 - 2000°F ± 0.4°C (0 - 60°C) ± 3% of rdg.0.1% 0 - 25% ± 0.1% vol rdg.ElectrochemicalO2 0.1% Barometric Pressure Solid State 260 - 1260 mbar 1 mbar ± 2 mbar 0 - 10% 0 - 20% 0.1% 0.1% ± 3% of rdg. ± 3% of rdg. ALL AQ INCUBA Kits Include: Ɣ Continuous Active Internal Sampling Pump Ɣ Operating Manual Ɣ Long Lasting Battery AC Charger Ɣ Factory Calibration Certificate Ɣ Differential Temperature Features CO2 Measurement Ɣ Sampling Hose Filter Ɣ Barometric Pressure Moisture Removal SystemƔ AQ INCUBA ORDERING CODE AQ INCUBA Kit CO2 Ambient Temp 100 O (0 - 25%)2 101 Optional Accessories Wireless Bluetooth™ Printer (EE900P) (E1500SP) Temperature Probe (AQMET) Moisture Exchange Tube 102 Barometric Pressure 0 - 5% 0 - 10% 0 - 20% Option Option Option Relative Humidity TFC 5 - 95% RH 0.1% RH ± 2% RH % Relative Humidity Ɣ (TRH-EXT) Temp. RH Extension Probe Temp. RH (AQ650078) Pack of 3 Moisture Filters
  53. 53. Easy to Use Menu System Optional Wireless Printer Barometric Air Pressure Optional Air Sampling Probe Large Internal Memory (2000) Portable Indoor Air Quality Monitor PC Software USB Included Long Lasting Rechargeable Battery E Instruments International www.E-Inst.com P: 215-750-1212 Wireless Communications with Computer Remote Printer Light Weight, Durable, and Easy to Transport Design F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 CO CO2 Customize UP to 7 Gases Providing the latest in Monitoring Data Logging for IAQ testing in Buildings, Hospitals, Universities, Labs, Clean Rooms, Airports more Portable w/ Swivel Handle Real-Time Data-Logging Software For Graphs, Data Review, IAQ Reports AQ EXPERT REAL-TIME Continuous Data-Logging Active Internal Sampling Pump Dual Temp TcK Inputs “Built with Quality in Mind” % RH Temp Barometric Pressure H S2 VOC Formaldehyde O2 NO2 NO 2SO O3 MADE IN USA (Multiple Parameters - Up to 12)
  54. 54. P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 E Instruments International www.E-Inst.com Features Applications CO2, CO, % RH, Temp, TVOC’s, O2, NO, NO2, O3, CH2O, SO2, H2S, Barometric Pressure Easy Calibration Custom to Your Application REAL-TIME Data Logging Save and graph using USB or wireless Bluetooth to a Computer or Tablet Made in USA Designed and manufactured in the USA AQ EXPERT NO CO2 O2 CO NO2 SO2 H2S NNNNNNOOOOOOOOOO % RH Built-in menu driven calibration procedure CH2O AQ Gas Real-Time Datalogging Software AQ G R l T ® Up to 7 different toxic gases to meet the needs of most air quality analyses VOCs VOCs
  55. 55. Sampling Probe P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 E Instruments International www.E-Inst.com Accessories AQ EXPERT Wireless Bluetooth Printer Carrying Case Air Velocity w/ Pitot Tube Parameter Sensor Range Res. Accuracy CO O2 Electrochemical 0 - 25% 0.1% ±0.1% vo rdg.l 0 - 200 ppm 0.1 ppm ±4% of rdg. ±0.5 ppm Electrochemical 0 - 100 ppm 1 ppm ±4% of rdg. ± 0.5 ppm Electrochemical NDIR 0 - 5,000 ppm 1 ppm ±2% of rdg. ±10 ppm PID 0 - 20,000 ppb 1 ppb ±10 % of rdg. ± 20 ppb HR%2±HR%1.0HR%59-5eviticapaCmliFnihT Pt100 -40 - 257°F 0.1°C/F ±2°F (32-140°F) Electrochemical 0 - 5 ppm 1 ppb VOCs % RH Temperature Ambient Ozone (O ) CO2 H S2 Specifications CO2 NDIR 0 - 20% 0.1% ±3% of rdg. VOCs PID 0 - 200 ppm (-40 - 125°C) (± 0.4°C [0-60°C]) 3 (0 - 46,000 μg/m ) (1 μg/m ) (0 - 460 mg/m ) (1 mg/m )3 3 3 3 1 ppm Other Ranges are Available Upon Request Accuracy Based on Laboratory Conditions1. 2. 3. 1 1 CH O2 bpp05±.gdr% of5bpp1lacimehcortcelE Barometric Pressure Solid State Temperature Type K T1 T2 Tc K 0 - 2000°F 1°C/F 2% of rdg. (0 - 1100°C) Air Velocity 0 - 300 ft/sec 1 ft/secCalculated Electrochemical 0 - 20 ppm 0.1 ppmNO2 NO Electrochemical 0 - 250 ppm 0.1 ppm 2SO Electrochemical 0 - 20 ppm 0.1 ppm Differential Pressure Bridge ±40.0 inH O 0.1 inH O ±1% of rdg.2 2 (±100 mbar) (0.25 mbar) 260 - 1260 mbar 1 mbar ±2 mbar Electromagnetic compatibility EN 61326-1, Portable Equipment 0 - 10,000 ppb 2,3 1 1 1 ±10 % of rdg. ± 2 ppm This sensor may have interference from H2 , CO, H2S and other reducing gases such as alcohols Moisture Exchange Tube for Calibration Ambient Air Zero Filter Exchange Calibration Ambient Air Zero Filter ±4% of rdg. ±0.5 ppm ±4% of rdg. ±0.5 ppm ±4% of rdg. ±0.5 ppm ± ±
  56. 56. P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 E Instruments International www.E-Inst.com AQ EXPERT ORDERING CODE Part Number: EXPERT-___-___-___-___-___ (Example: EXPERT-C2-C-V1 = 2 Ambient Temp, % RH, Barometric Pressure, CO (0-5000 ppm), CO (0-200 ppm), VOC (0-20,000 ppb) AQ EXPERT Base Unit Including: - Ambient Temperature, % Relative Humidity - Barometric Pressure, Wet Bulb Dew Point - - REAL-TIME data logging - PC Software (with USB Cable) - Wireless Bluetooth External Dongle - Dual-channel TcK (Diff. Temp) - Differential Pressure - Operating Manual - Swivel Handle for Easy Transport - Rechargeable Battery AC Charger - Factory Calibration Certificate ADD UP TO 7 (SEVEN) ADDITIONAL SENSORS FROM THE LIST BELOW: PART NUMBER DESCRIPTION Expert- AQ Expert Base Unit w/ Ambient Temp, %RH, Barometric Pressure 2CO Sensor (0-5,000 ppm)-C2 -C CO Sensor (0-200 ppm) -V1 VOC Sensor (0-20,000 ppb) -V2 VOC Sensor (0-200 ppm) -N NO2 Sensor (0-20 ppm)** -Z O3 Sensor (0-5 ppm)** -H H2S Sensor (0-100 ppm) -O O2 Sensor (0-25%) -S SO2 Sensor (0-20 ppm)** -X NO Sensor (0-250 ppm) -F CH2O Sensor (0-10,000 ppb) OPTIONAL ACCESSORIES: PART NUMBER DESCRIPTION E858140 Protective Carrying Case E85AACSF13 12” (300mm) Probe, 10’ (3m) Dual Hose EE900P Bluetooth Wireless Printer BB610032 12” (300mm) Pitot Tube (Air Velocity) AACKP01 Differential Pressure Kit AQ EXPERT * * * * * Other Ranges are Available Upon Request Bulletin:AQEXPERT.2Ed.01/2017Informationdesignsubjecttochangeatthemanufacture’sdiscretion. Note: All 3 O3, NO2, SO2 Sensors Cannot Concurrently be Installed on one Instrument ** - Differential Temperature * Continuous Internal Sampling Pump * AQ CAL-ZF Ambient Air Zero Filter AQ MET Moisture Exchange Tube for Calibration
  57. 57. Application Notes Indoor Air Quality E Instruments is Proud to Offer A Wide Variety of In-Depth Application Notes to its Customers Such As: The Toxic Effects of Hydrogen Sulfide (H˺S) Gas From Sewers on Health Infrastructure Application Note # AQ-14-0723 VOCs: An Indoor Air Quality Health RiskApplication Note # AQ-13-0601 Warehouses Why Energy Auditors Need to Measure CO˺Application Note # AQ-14-0313 Manufacturing Facilities Architecture Buildings For a Complete List of Our Application Notes Please Visit Our Website at www.E-Inst.com Laboratories Hospitals Medical Incubators Research Development Clean Rooms Building Hygiene Industrial Hygiene LEED Certification Universities
  58. 58. Air Quality Probes Accessories 12(300mm) Standard Probe (gas draft), 1470F (800C) max, with 10'(3m) dual hose Standard Probe Temp. %RH module extension cable for testing inside incubators Temperature Humidity Module Extension Tem cable ity Hose and moisture filter for testing inside incubatorsIncubator Sampling Hose Tubing for equalizing humidity in span gas with atmosphereMoisture Exchange Tube T in (See Figure 1 Below) Disposable filter for simple zero calibration of gas sensorsAQ Zero Filter be diity Disposa calibratFilter (Figure 1)
  59. 59. For more information about our products please call: (215) 750-1212 or visit our website at: www. E-Inst.com Built With Quality In Mind E Instruments International is a designer, manufacturer, provider of a complete range of innovative instrumentation solutions including portable combustion gas and emissions analyzers, automotive exhaust analyzers, gas leak detectors, and IAQ Monitors, which we export to over 65 countries worldwide. more

×