Ascada remote-monitoring-of-equipment-and-objects

834 views

Published on

remote-monitoring-of-equipment-and-objects-ASCADA

Published in: Technology, Business
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
834
On SlideShare
0
From Embeds
0
Number of Embeds
71
Actions
Shares
0
Downloads
9
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Ascada remote-monitoring-of-equipment-and-objects

  1. 1. Avoid worries , save time and money ASCADA - remote equipment and objects monitoring system
  2. 2. Problem and solution <ul><li>Remote monitoring! </li></ul>Difficulties in geographically dispersed equipment monitoring ? Solution
  3. 3. ASCADA - remote equipment and objects monitoring system A complex solution for work processes automation Accounting Monitoring Control On-line !
  4. 4. System capabilities <ul><li>Measurements , results processing , database storage </li></ul><ul><li>Online data display at the workstation </li></ul><ul><li>Report generation , editing, printout </li></ul><ul><li>Equipment operability monitoring </li></ul><ul><li>Multilevel unauthorized access protection </li></ul><ul><li>Competent , technically reasonable management at various levels </li></ul>
  5. 5. Problems to solve <ul><li>Equipment with no built - in features for remote monitoring </li></ul><ul><li>Expensive site maintenance visits </li></ul><ul><li>Painful losses due to equipment underperformance and untimely detected defects </li></ul><ul><li>Expensive equipment can fail between maintenance visits </li></ul><ul><li>Difficulty to detect early failure symptoms </li></ul>
  6. 6. Main idea Sensor RS-232 interface Older equipment that has only local interfaces and lacks some needed sensors Central server Communication channel (GSM, Internet, … ) Custom-made monitoring and control software that provides web access Controller Web client
  7. 7. Technical details <ul><li>RS-232, RS-485, Ethernet interfaces </li></ul><ul><li>Power consumption – max. 50 VA </li></ul><ul><li>Supply voltage – 187-242 V </li></ul><ul><li>Overall dimensions – max. 190 x114x 85 mm </li></ul><ul><li>Weight – max. 3 kg </li></ul><ul><li>Mean lifetime – min. 12 years </li></ul><ul><li>MTBF – min. 20 000 h </li></ul>
  8. 8. Communication channels <ul><li>Internet through Ethernet </li></ul><ul><li>GSM channels for data transmission (standard GPRS) </li></ul><ul><li>Radio channels for data transmission </li></ul><ul><li>FO communication lines </li></ul><ul><li>Cable TV networks </li></ul><ul><li>Telephone lines </li></ul>
  9. 9. Associated equipment <ul><li>Measurement components </li></ul><ul><li>pressure sensor , </li></ul><ul><li>temperature sensor , </li></ul><ul><li>flow sensor , </li></ul><ul><li>volume sensor , </li></ul><ul><li>vibration sensor , </li></ul><ul><li>voltage sensor , </li></ul><ul><li>current sensor </li></ul><ul><li>Auxiliary components </li></ul><ul><li>- lightning protection units , </li></ul><ul><li>UPS units , </li></ul><ul><li>printers, etc . </li></ul>
  10. 10. Advantages Cost effective – € 3,000 – 4,000 per node Risk free – no satisfaction – no invoice Flexible – many interfaces, any sensors
  11. 11. Customer benefits <ul><li>15-25% energy saving </li></ul><ul><li>Up to 3-8 times shorter emergency response time </li></ul><ul><li>5-7 times accident reduction due to the prediction </li></ul><ul><li>on key parameters </li></ul><ul><li>System pay-off period: around 1 year in industrial facilities, 2-3 years in residential buildings </li></ul>
  12. 12. Next steps Request with technical details and number of objects Research and commercial offer Pilot area opening , if reasonable If you are satisfied : Full-scale contract Delivery, installation Maintenance , extensions
  13. 13. Contacts Viktoria Anatsko Marketer SIS Group International, Belarus Tel. : +375 17  259 13 81 Mob.: +375 29 572 02 01 e-mail: [email_address] http :// www.sis-group.com We are looking forward to working together!

×