Sinoscopy ENT Catalogue

4,093 views

Published on

Sinoscopy ENT Catalogue

Published in: Health & Medicine
0 Comments
2 Likes
Statistics
Notes
  • Be the first to comment

No Downloads
Views
Total views
4,093
On SlideShare
0
From Embeds
0
Number of Embeds
10
Actions
Shares
0
Downloads
0
Comments
0
Likes
2
Embeds 0
No embeds

No notes for slide

Sinoscopy ENT Catalogue

  1. 1. Medical Catalogue Endoscopy Visualisation solutions in sight Fiberoptics Engineering Service Schölly Fiberoptic GmbH Fon + 49 (0) 76 66 / 908-0 eMail info@schoelly.de Robert-Bosch-Strasse 1-3 Fax + 49 (0) 76 66 / 908-380 Internet www.schoelly.de D -79211 Denzlingen Fax-Service + 49 (0) 76 66/ 908-381 MPC003-000-0610-01
  2. 2. Minimal Invasive Surgery Fields of application of Schölly medical products • 3D Robot Surgery „Da Vinci® “ • Laparoscopy • Plastic Surgery • Arthroscopy • Neurosurgery • Spinal Surgery • Dermatology • Ophthalmology • Urology • Gynecology • Pediatrics • Vessel Harvesting • ENT • PDT • Your Application?
  3. 3. More than 30 years experience in the medical field The Company Schölly does not only stand for carefully engi- neered high-end products. We are also commit- ted to corporate ethics and responsibility in dea- ling with our employees, customers, business partners, suppliers and our home town Denzlingen alike. For more than 30 years now, we have been maintaining a corporate culture that is both self- contained and open to inspiration from the out- side world. Our teams are staffed with professio- nals who create superior products of utmost reli- ability, based on future-oriented, well-integrated designs. By focusing our creative energy, we can offer visualization technology that is tailor-made to the needs of our customers: solutions in sight. Corporate History Since its establishment in 1973 our company has evolved from a single-product manufacturer to a vendor of high sophisticated visualization systems. At our Denzlingen site alone, a work- force of about 200 team members develop and manufactur a yearly output of next to 13,000 visualization systems. At the same time a net- work of agencies spans the globe to cater for our customers’ needs worldwide. The future will see an increasing miniaturization of our medical devices, aimed at easing minimal invasive surgery for patients even further. In engineering, new fields of application will open up as modular optical probes converge with camera imaging and video archiving technologies. I-06
  4. 4. Our Program Visualization for medical and engineering applications is our core business. All products made by Schölly are targeted at making concealed structures visible and accessible for non-destructive/mini- mal invasive treatment, using technology such as micro-optics, fiberoptics and electronics. We design, manufacture and sell all components dedicated to that purpose independently from the endoscope, almost a classic in our product line, to highly complex visualization systems. Long-term partnerships with OEM customers and users promote the continuous improvement and further development of our products as well as research into new fields of application. Our flexibility and readiness to adapt to other mindsets and markets has added much to our credit with partners worldwide. Quality Management System DIN EN ISO 9001:2000 Reg.-Nr. 058247 QM DIN EN ISO 13485:2001 Reg.-Nr. 058247 MP21 DIN EN ISO 13485:2003 Reg.-Nr. 058247 MP23 Anh. II RL 93/42/EWG Reg.-Nr. 058247-07 Reliability & Precision To support minimal invasive medical applications we offer visualization systems for diagnostics and surgery. The main goal here is to anticipate specific customer requirements and translate them into marketable and cost-effective products and systems. By continuously investing in the improvements of existing products, we guarantee to our customers optimal product quality and make their life easier. This means that our endoscopes and fiber-optic systems must meet extremely exacting demands in terms of image quality, reliability and corrosion resistance in order to perform well under the extreme conditions of use that are so frequently met in medical applications. I-06
  5. 5. * Orthopedics * Laparoscopy * Gynecology * Urology * Ear - Nose - Throat Light Sources, Cameras & Accessories FlexiFairplay Technology & Special Endoscopes * Copyright 1998 3B Scientific GmbH, Hamburg, Germany I-06
  6. 6. Ear - Nose - Throat I-06
  7. 7. Content ENT * Ear - Nose - Throat Page Content ENT 500 Sinuscopes Ø 1.7/2.7 mm, Otoscopes Ø 2.7 mm ENT 501 Sinuscopes Ø 4.0 mm, Pharyngoscopes ENT 502 Pharyngoscopes ENT 503 Trocar sleeves and trocars ENT 504 Endoscope hand pieces ENT 505 Instruments * Copyright 1998 3B Scientific GmbH, Hamburg, Germany I-06
  8. 8. ENT Sinuscopes FlexiLux - Sinuscope, soakable FlexiLux - Otoscopes, soakable Endoscope-Ø: 1.7 mm Working-Ø: 2.7 mm Working length: 96 mm Working length: 34 mm Minioptic 31.0022s Viewing direction: 0° wide angle 21.0130s Viewing direction: 0° standard 31.0023s As item no. 31.0022s but with adapter for ear speculum 31.0060s Ear speculum for otoscope item no. 31.0023s 1 box = 10 pieces FlexiLux II - Sinuscopes FlexiLux II - Sinuscopes Endoscope-Ø: 2.7 mm Endoscope-Ø: 4.0 mm Working length: 110 mm Working length: 175 mm 31.0005a Viewing direction: 0° standard 21.0003a Viewing direction: 0° wide angle 31.0007a Viewing direction: 30° standard 21.0013a Viewing direction: 30° standard 31.0009a Viewing direction: 70° standard 21.0008a Viewing direction: 30° wide angle 21.0101a Viewing direction: 45° wide angle 21.0011a Viewing direction: 70° wide angle FlexiLux II - Sinuscopes FlexiLux II - Sinuscopes Endoscope-Ø: 2.7 mm Endoscope-Ø: 2.7 mm Working length: 187 mm Working length: 187 mm 21.0617a Viewing direction: 0° standard 21.0619a tu Viewing direction: 30° standard 21.0619a Viewing direction: 30° standard 21.0621a tu Viewing direction: 70° standard 21.0621a Viewing direction: 70° standard Endoscope-Ø: 4.0 mm Working length: 175 mm 21.0008a tu Viewing direction: 30° standard 21.0101a tu Viewing direction: 45° standard Viewing direction rotated 180° light cable connector. ENT 500 I-06
  9. 9. ENT Sinuscopes/Pharyngoscopes Tele-Laryngo-Pharyngoscope • Sharp image, significant depth of field • High performance illumination • 2 different magnifications: Panoramic view and examination of details • Integrated air channel for prevention of condensation (with Luer-Lock connection) • Soakable and gas sterilizable 31.0606s FlexiLux Tele-Laryngo-Pharyngoscope Working diameter: 10 mm Working length: 153 mm, rigid Viewing direction: 90° Working distance: 15 mm to infinity Magnification: 1 : 1.6 FlexiLux II Sinuscopes Endoscope-Ø: 4.0 mm Compatible to the brands Wolf and Stryker Compatible to system Wolf Working length: 170 mm 21.0051a Viewing direction 25° wide angle 21.0053a Viewing direction 70° wide angle Compatible to system Stryker Working length: 142 mm 21.0081a Viewing direction 30° wide angle with Stryker coupler I-06 ENT 501
  10. 10. ENT Naso-Pharyngoscopes Naso-Pharyngoscope 3.2 mm Nase-Pharyngoscope 3.8 mm • Conventional image bundle, 7,000 pixels • Conventional image bundle, 12,000 pixels • 2 way deflection • 2 way deflection • One hand operation • One hand operation • Completely soakable and designed for gas • Completely soakable and designed for gas sterilization sterilization 31.1001s Flexible Naso-Pharyngoscope 31.0001s Flexible Naso-Pharyngoscope with ETO valve mit ETO valve Scope of delivery: transport case, leakage Scope of delivery: transport case, leakage tester, light guide 05.0086L tester, light guide 05.0086L Working length: 300 mm Working length: 300 mm Working-Ø: 3.2 mm Working-Ø: 3.8 mm Deflection: up 160°, down 160° Deflection: up 125°, down 125° Length of movable Length of movable tip section: 20 mm tip section: 25 mm Viewing direction: 0° wide angle Viewing direction: 0° wide angle Field of view 90° Depth of focus: 5 mm to infinity Depth of focus: 3 mm to 60 mm Leakage tester On request all flexible Nose-Pharyngoscopes are available for left-hand use. ENT 502 I-06
  11. 11. ENT Trocar sleeves/Trocars For Sinuscopes - Ø 1.7 mm Für Sinuscopes - Ø 2.7 mm Trocar Sleeve with 1 fixed stop cock Trocar Sleeve with 1 fixed stop cock 21.0145a Trocar Sleeve 31.0628a Trocar Sleeve Working length: 96 mm Working length: 110 mm Ø outside: 2.5 mm Ø outside: 3.4 mm Suitable for item no.: 21.0130s For endoscopes with viewing direction: 0°, 30°, 70° Trocar Sleeve with two stop cocks, rotatable Trocar Sleeve with two stop cocks, rotatable 21.0146a Trocar Sleeve 31.0631a Trocar Sleeve Working length: 96 mm Ø outside: 2.5 mm Working length: 110 mm Suitable for item no.: 21.0130s Ø outside: 3.4 mm For endoscopes with viewing direction: 0°, 30°, 70° 31.0632a Trocar Sleeve Working length: 110 mm Ø outside 3.4 mm For endoscopes with viewing direction: 30° 21.0147a Trocar with 3 edges 31.0630a Trocar with 3 edges Suitable for item no.: 21.0145a Suitable for item no.: 31.0628a 21.0146a 31.0631a 31.0632a 21.0148a Trocar blunt 31.0629a Trocar blunt Suitable for item no.: 21.0145a Suitable for item no.: 31.0628a 21.0146a 31.0631a 31.0632a All trocars are secured against rolling off. I-06 ENT 503
  12. 12. ENT Endoscope Handle/Instruments Endoscope Handles Ø 2.7 mm Endoscope Handles Ø 4.0 mm 31.0202a Endoscope Handle, round 31.0201a Endoscope Handle, round Suitable for item no.: 21.0617a Suitable for item no.: 21.0003a 21.0619a 21.0008a 21.0621a 21.0101a 31.0005a 21.0011a 31.0007a 21.0013a 31.0009a 31.0203a Endoscope Handle, 2 surfaces 31.0200a Endoscope Handle, 2 surfaces Suitable for item no.: 21.0617a Suitable for item no.: 21.0003a 21.0619a 21.0008a 21.0621a 21.0101a 31.0005a 21.0011a 31.0007a 21.0013a 31.0009a 31.0620a Gumholeaspirator, with short edge 31.0654a Suction and Irrigation Tube ø 3.0 mm ø 5.0 mm 31.0624a Suction Canula, short, smooth 31.0618a Antrum- and Sinuscopy Trocar ø 3.0 mm Ø 5.0 mm, incl. pyramid-shaped trocar ENT 504 I-06
  13. 13. ENT Instruments 31.0683a Biopsy Punch, straight, vertical 31.0668a Sickle Knife, 200 mm 3.0 mm double mobile 31.0669a Sickle Knife, 200 mm, long curved 31.0670a Nasal Cutting Forceps, Weil-Blakesley, sharp, without neck, straight, 190 mm 31.0667a Spoon, sharp, round form, 200 mm 31.0665a Spoon, sharp, small form, 200 mm 31.0671a Nasal Cutting Forceps, Weil-Blakesley, sharp, without neck, 45°, 190 mm 31.0666a Spoon, sharp, oval form, 200 mm 31.0678a Nasal Scissors, straight 31.0658a Septum-Elevator, „Freer“ sharp/blunt, 180 mm 31.0676a Nasal Scissors, right curved 31.0677a Nasal Scissors, left curved I-06 ENT 505
  14. 14. Light sources, Cameras & Acessories I-06
  15. 15. Content Light Sources, Cameras & Accessories Light Sources, Cameras & Accessories Page Content ACC 600 FlexiLux LED-/Halogen light sources ACC 601 FlexiLux 50 MH, FlexiLux 180X light sources ACC 602 Adapter fitting to FlexiLux 50MH, 180X ACC 603 FlexiLux 300X Xenon light source ACC 604 Light guide cables and adapters ACC 605 FlexiScope IQ101 Compact camera ACC 606 FlexiScope IQ101 Compact camera power cords ACC 607 FlexiScope C1301 camera ACC 608 FlexiScope C33001 3CCD camera ACC 609 FlexiScope 50MH light source-camera unit ACC 610 FlexiScope 50MH light source-camera unit ACC 611 FlexiScope 180X-CC light source-camera unit ACC 612 FlexiScope 180X-301 light source-camera unit ACC 613 FlexiScope 180X-3CCD light source-camera unit ACC 614 TV adapter ACC 615 Camera cable ACC 616 Peripheral units ACC 617 LCD video monitors 15”/19” ACC 618 FlexiView image archiving software ACC 619 FlexiCart video cart ACC 620 Endoscope baskets, sterisafes, eye pieces I-06
  16. 16. Light Sources FlexiLux 3LED FlexiLux 3000 High Power 3 Watt LED Light Source Halogen Power Light Source Small handsome and mobile light source with roll-off Light, robust synthetic casing, continuous control of protection. Battery supplied with one 3 Volt high brightness, lateral plug-in unit for colour filter, power lithium battery. Perfect for office or in the field stackable, simple bulb exchange, longer average wor- use e.g. ENT or other applications. king life of bulb due to soft start function. Lamp type: Luxeon 3 Watt LED Colour temperature: 5,500 Kelvin (nominal) Light intensity: 35 K Lux (nominal) Lamp life: > 10,000 h (nominal) Battery: 1 x Lithium CR123A, 3 Volt Nominal power 150 W Illumin. period: approx. 110 min. Colour temperature: 3,250 Kelvin per Battery charge Light intensity: 9.2 Mio. Lux Light guide connection: compatible with ACMI Average lamp life: Step 4: 1,500 h Dimension (mm): 83 x 26 (L x ø) Step 5: 200 h Weight: 75 g Light guide connection: compatible with Schölly Dimension (W x H x D): 168 x 120 x 268 mm 05.0750led.ac FlexiLux 3LED 05.0750led.bat 2 x lithium CR123A, 3 Volt 05.0165h.240 220 - 230 Volt AC, 50/60 Hz as spare part 05.0166h.120 110 - 120 Volt AC, 50/60 Hz 05.0750led.ac.set FlexiLux 3LED, incl. 3 rechargeable 05.0167h Spare lamp 150 W halogen lithium batteries and charger as set FlexiLux 650.2 FlexiLux 250.2 H Standard Light Source High power Economy Light Source Switchable, with an integrated spare lamp. High inten- Switchable, with an integrated spare lamp. High sity, incl. iris diaphragm, low noise fan with reduced intensity, incl. iris diaphragm, powerful fan, optical air turbulence. light concentrator for optimized use of the existing light energy. Nominal power Nominal power Active position: 1 x 150 W Active position: 1 x 250 W Spare position: 1 x 150 W Spare position: 1 x 250 W Colour temperature: 3,200 Kelvin Step 1 Step 2 Light intensity: 12 mio. Lux Colour temperatur: 3,100 3,230 Kelvin Lamp life: 50 h (average) Light intensity: 5.6 7.8 Mio.Lux Connection: 115/230 V AC Lamp life: 400 100 St. switchable (50/60 Hz) Light guide connection: compatible with Schölly Light guide connection: compatible with Storz Dimension (W x H x D): 258 x 110 x 263 mm Dimension (W x H x D): 367 x 132 x 250 mm 05.0080h 115 - 230 Volt AC, 50/60 Hz 05.0082h 115 V - 230 V AC, 50/60 Hz 05.0136h Spare lamp 150 W Halogen 05.0081h Spare lamp 250 W halogen ACC 600 I-06
  17. 17. Light Sources FlexiLux 50MH Very compact, light intensive metal halide light source with xenon-like colour temperature, a long lamp life and a low power consumption. • Operation control front plate ON/OFF • Nominal power 50 W metal halide • Colour temperature 4,500 Kelvin • Light output 10.5 mio. Lux • Lamp life 2.500 h (average) • Power connection 100-250 V AC, 50/60 Hz, 110 VA • Light cable connector changeable, compatible to system Storz, stepless illumination adjustment with diaphragm • Dimensions/Weight 263 x 100 x 315 mm (W x H x D) approx. 3.8 kg 05.0800mh FlexiLux 50MH, incl. Storz light guide adapter 05.0140mh Spare lamp for FlexiLux 50MH FlexiLux 180X Compact and powerful xenon light source for all needs. • Operation control front plate ON/OFF with LED indicator, lifetime (bulb) indicator • Nominal power 180 W Xenon • Colour temperature 6,000 Kelvin • Light output 25 mio. Lux • Lamp life 500 h (average) • Power connection 100-250 V AC, 50-60 Hz, 400 VA • Light cable connector Light cable connector compatible to system Storz, stepless illumination adjustment with mechanical diaphragm • Dimensions/Weight 360 x 128 x 320 mm (W x H x D) approx. 6.8 kg 05.0620x.m1 FlexiLux 180X, incl. Storz light guide adapter 05.0139x.m1 Spare lamp for FlexiLux 180X (for models as of 2004) 05.0139x Spare lamp for FlexiLux 180X (for models as of 2003) I-06 ACC 601
  18. 18. Adapter Adapter suitable for Schölly FlexiLux light sources 50MH, 180X 05.0601r.st Light guide connector for Storz compatible light guides 05.0601r.sc Light guide connector for Schölly compatible light guides 05.0601r.wo Light guide connector for Wolf compatible light guides 05.0601r.ac Light guide connector for ACMI compatible light guides 05.0601r.ol Light guide connector for Olympus compatible light guides 05.0601r.dy Light guide connector for Dyonics compatible light guides ACC 602 I-06
  19. 19. Light Source FlexiLux 300X High Power 300 Watt xenon light source for all applications which require a specially high quantity of light. • Operation control front plate ON/OFF with LED indicator, lifetime (bulb) indicator • Nominal power 300 W Xenon • Colour temperature 6,000 Kelvin • Light output 50 mio. Lux • Lamp life 500 h (average) • Power connection 120-240 V AC, 50/60 Hz, 850 VA, automatic change over • Light guide connector adjustable, compatible to Storz, ACMI, Wolf, Olympus, stepless illumination adjustment with mechanical diaphragm • Dimensions/Weight 360 x 140 x 260 mm (W x H x D) approx. 6.8 kg Item numbers 05.0625x FlexiLux 300X 05.0626x Spare lamp module for FlexiLux 300X I-06 ACC 603
  20. 20. Light Guide Cable & Adapter Hightrans Light Cable Light cable adapters* - light source end armored and highly flexibleg (s. picture 1 ) suitable for light cables and Strain relieved by kevlar and protected by a sturdy silicone tube, guaranteed autoclavable, internal ben- 05.0100z Storz light sources ding protection at the light source end, min. 5,000 V overvoltage protection, incl. adapters for your end- oscope and light source. Please indicate when ordering 05.0102b Wolf light sources with which adapters the light cable should be delive- red. In case this information should be missing we would automatically deliver the light cable suitable for STORZ system. 05.0107r Fujinon light sources 05.0104f SCHÖLLY light sources 1 05.0106c ACMI light sources (Circon) 05.0101o Olympus light sources 05.0103o Schölly adapter for 2 3 Olympus light sources LCV-S 20, -30, -40 05.0084l Length: 1.8 m Light cable adapters* - endoscope end Fiber-Ø: 3.5 mm (s. picture 2 ) suitable for light cables and 05.0088l Length: 2.3 m Fiber-Ø: 3.5 mm 05.0108z Storz endoscope 05.0085l Length: 3.0 m Fiber-Ø: 3.5 mm 05.0086l Length: 1.8 m 05.0110b Wolf endoscope Fiber-Ø: 4.8 mm 05.0090l Length: 2.3 m 05.0112c ACMI endoscope Fiber-Ø: 4.8 mm (Circon) 05.0087l Length: 3.0 m Fiber-Ø: 4.8 mm * One adapter set included per endoscope. Same features as standard light guide, but recommen- ded for xenon light sources over 180 W: Optic Adapters (s. picture 3 ) suitable for 05.0090L HT Lenth: 2.3 m Fiber-Ø: 4.8 mm 05.0114z Storz light cable* 05.0116b Wolf light cable* 05.0115z Schölly angulated light port adapter (optimized light distribution) compatible to system Storz Screw sleeves at the optic. All Schölly endoscopes with fix integrated ACMI (Circon) compatible light guide connector. * Included in delivery of a Schölly endoscope. ACC 604 I-06
  21. 21. Camera 1CCD FlexiScope IQ101 Compact CCD Camera Compact 1CCD camera system with integrated electronics in camera head. 2 camera head versions for standard endoscopes and optimized for image bundle endoscopes in combination with 2 different smartboxes (Video/ S-Video or Video/USB 2.0). Camera head Smartbox White balance/ Function key window function Video Video/USB 2.0 Optionally available as anti-Moiré version with removable TV adapter • Operation control Hand piece: White balance/window function, function key • Smartbox outputs Version video: 1 x S-Video (Y/C), 1 x Video (FBAS) Version video, USB: 1 x USB 2.0, 1 x Video (FBAS) • Camera head Image sensor: 1/3" CCD Image resolution lines: 470 (H) x 420 (V) PAL 470 (H) x 350 (V) NTSC Image resolution act. pixels: 440,000 (PAL)/380,000 (NTSC) Light sensitivity: 2 Lx/f = 1.4 Endoscope coupler: Standard eye piece, C-mount, detachable Focal length TV adapter: f = 23 mm Versions: with/without integrated anti-Moiré filter • Disinfection/Sterilisation Camera head soakable in liquids, suitable for disinfection • System Acc. guideline Med. Prod. 93/42 EWG Class 1 Electromagn. compatibility: EN 60601-1 Classification: BF/CE mark Power connection: 100-240 V AC, 50/60 Hz Power consumption: 2 VA Separat power supply • Dimensions/Weight Smartbox: 80 x 34 x 170 mm (W x H x D) Camera head: 135 x 50 mm (L x ø) Camera cable: 3m Weight smartbox: max. 200 g Weight camera head: 300 g I-06 ACC 605
  22. 22. Camera 1CCD Item numbers 95.2050s.CC Flexiscope IQ101 Compact, PAL 95.2050s.CC.DIG Flexiscope IQ101 Compact, PAL, USB 2.0, FlexiView 95.2053s.CC FlexiScope IQ101 Compact anti-Moiré, PAL 95.2053s.CC.DIG FlexiScope IQ101 Compact anti-Moiré, PAL, USB 2.0, FlexiView NTSC versions available on request. The FlexiView software for simple image recording and storage is included in delivery of cameras with USB 2.0 interface. Power cords has to be ordered separately together with chosen camera! 05.0700r.cord.eu Power cord Euro CEE 7/7 05.0700r.cord.indaf Power cord India/Africa BS 546 05.0700r.cord.uk Power cord UK BS 1363 05.0700r.cord.na Power cord USA Medical grade 05.0700r.cord.jap Power cord Japan JIS 8303 05.0700r.cord.chi Power cord China GB2099.1 Without anti-Moiré Filter With anti-Moiré Filter The anti-Moiré filter provides opti- mization of image quality at appli- cation of image bundle endo- scopes are used. It reduces arte- facts significantly. ACC 606 I-06
  23. 23. Camera 1CCD FlexiScope C1301 Camera Fine adjustable 10 bit 1CCD camera with 3 presettings. Camera head, bent Camera head, straight Camera head with self-adjusted TV adapter (for Resectoskope applications) • Operation control ON/OFF with LED indicator, white balance, window function, preset function with three selectable basic setups - all with OSD/LED indicator, contrast/brightness adjustment with OSD indicator • Camera controller Outputs: 1 x S-Video (Y/C), 1 x Video (FBAS) • Camera head Image sensor: 1/2" CCD Image resolution lines: 470 (H) x 420 (V) PAL 470 (H) x 350 (V) NTSC Image resolution act. pixels: 440.000 (PAL)/380.000 (NTSC) Light sensitivity: 2 Lx/f = 1.4 Endoscope coupler: Standard eye piece, C-mount, detachable Focal length TV adapter: f = 30 mm, with integrated anti-Moiré filter • Disinfection/Sterilisation Camera head soakable in liquids suitable for disinfection; compatible to Steris® • System Acc. Guideline Med. Prod. 93/42 EWG Class 1 Electromagn. compatibility: EN 60601-1 Classification: BF/CE mark Power connection: 100-240 V AC, 50/60 Hz Power consumption: 25 VA • Dimensions/Weight Camera station: 360 x 88 x 320 mm (W x H x D) Weight: approx. 4 kg Camera head and adapter: approx. 140 x 60 mm (L x ø) Camera cable: 3m Item numbers 95.2007s.C1 FlexiScope C1301 with Camera head, straight, PAL 95.2008s.C1 FlexiScope C1301 with Camera head, bent, PAL 95.2015s.C1 FlexiScope C1301 with Camera head, self-adjusted TV adapter, PAL NTSC versions available on request. I-06 ACC 607
  24. 24. Camera 3CCD FlexiScope C33001 3CCD Camera Fine adjustable 3CCD camera with 3 preset programs - individually to customize by user. White balance Function key • Operation control ON/OFF with LED indicator, white balance, window function, preset function with three selectable basic setups - all in OSD menu modifiable, brightness adjustment with OSD indicator Camera head: white balance, function key • Camera controller Outputs: 1 x RGB Sub-D 2 x S-Video (Y/C) 1 x Video (FBAS) 1 x 3.5 mm cinch for remote control • Camera head Image sensor: 3 x 1/3" CCD Image resolution lines: 750 (H) x 430 (V) PAL 750 (H) x 350 (V) NTSC Image resolution act. pixels: 440,000 (PAL)/380,000 (NTSC) Light sensitivity: 5 Lx/f = 2.2 Endoscope coupler: Standard eye piece, C-mount, detachable Focal length TV adapter: f = 23 mm • Disinfection/Sterilisation Camera head soakable in liquids, suitable for disinfection, compatible to Steris® and Sterrad® • System Acc. guideline Med. Prod. 93/42 EWG Class 1 Electromagn. compatibility: EN 60601-1 Classification: BF/CE mark Power connection: 100-250 V AC, 50/60 Hz Power consumption: 25 VA • Dimensions/Weight Camera station: 360 x 88 x 320 mm (W x H x D) Weight: approx. 4.1 kg Camera head and adapter: 165 x 50 mm (L x ø) Camera cable: 3m Item number 05.9090s.m1 FlexiScope C33001 NTSC versions available on request. ACC 608 I-06
  25. 25. Light Source-Camera Unit FlexiScope 50MH - Light Source-Camera Unit The FlexiScope 50MH incorporates the compact, easy-to-use 1CCD Camera IQ101 Compact, combined with a compact high intensity metal halide light source. The new metal halide lamp technology guarantees a high light intensity with a low power consumption as well as a xenon-like colour temperature and a long lamp life. The elec- tronic, which is integrated in the camera head offers an optimized image quality. Optional, a digital USB 2.0 inter- face with an easy-to-handle picture recording software (FlexiView) is available. For application with image bundle endoscopes, we recommend the optional available version with integrated anti-Moiré filter. Function key White balance/ Window function • Camera Operation control: White balance/window function, function key • Camera controller Outputs: 1 x S-Video (Y/C), 1 x Video (FBAS) 1 x USB 2.0 (optional) • Camera head Image sensor: 1/3" CCD Image resolution lines: 470 (H) x 420 (V) PAL 470 (H) x 350 (V) NTSC Image resolution act. pixels: 440,000 (PAL)/380,000 (NTSC) Light sensitivity: 2 Lx/f = 1.4 Endoscope coupler: Standard eye piece, C-mount, detachable Focal length TV adapter: f = 23 mm Versions: w/o integrated anti-Moiré filter • Disinfection/Sterilisation Camera head soakable in liquids, suitable for disinfection I-06 ACC 609
  26. 26. Light Source-Camera Unit • Data light source ON/OFF Light guide connector (changeable) compatible with system Storz, stepless illumination adjustment with diaphragm Nominal output: 50 W metal halide Colour temperature: 4,500 Kelvin Light output: 10.5 mio. Lux Lamp life: 2,500 h (average) • System Acc. guideline Med. Prod. 93/42 EWG Class 1 Electromagn. compatibility: EN 60601-1 Classification: BF/CE mark Power connection: 100-250 V AC, 50/60 Hz, 110 VA • Dimensions/Weight: Housing: 263 x 100 x 315 mm (W x H x D) Weight: 4 kg Camera head: approx. 135 x 50 mm (L x ø) Camera cable: 3m Item numbers 95.1011mh FlexiScope 50MH; 50 W LS. + Compact Camera, PAL 95.1011mh.a FlexiScope 50MH; 50 W LS. + Compact Camera, PAL, anti-Moiré 95.1011mh.d FlexiScope 50MH; 50 W Lv. + Compact Camera, PAL, USB 2.0, FlexiView 95.1011mh.a.d FlexiScope 50MH; 50 W LS. + Compact Camera, PAL, anti-Moiré, USB 2.0, FlexiView 05.0140mh Spare lamp metal halide NTSC versions available on request. The FlexiView software for simple image recording and storage is included in delivery of cameras with USB 2.0 interface. ACC 610 I-06
  27. 27. Light Source-Camera Unit FlexiScope 180X-CC - Light Source-Camera Unit The FlexiScope 180X-CC incorporates a Schölly IQ101 Compact Camera - a compact 1CCD camera system, combined with a high intensity 180 W xenon light source for maximal light intensity. The electronics, which is integrated in the camera head offers an optimized image quality. For application with image bundle endoscopes, we recommend the optional available version with integrated anti-Moiré filter. Function key Withe balance/ Window function • Operation control Camera head: White balance/window function, function key • Camera controller Outputs: 1 x S-Video (Y/C), 1 x Video (FBAS), USB 2.0 (only digital version), remote output • Camera head Image sensor: 1/3" CCD Image resolution lines: 470 (H) x 420 (V) PAL 470 (H) x 350 (V) NTSC Image resolution act. pixel: 440,000 (PAL)/380,000 (NTSC) Light sensitivity: 2 Lx/f = 1.4 Endoscope coupler: Standard eye piece, C-mount, detachable Focal length TV adapter: f = 23 mm • Disinfection/Sterilisation Camera head soakable in liquids, suitable for disinfection • Data light source ON/OFF with LED indicator, lifetime (bulb) indicator, Nominal output: 180 W xenon Colour temperature: 6,000 Kelvin Light output: 25 mio. Lux Lamp life: 500 h (average) Light guide connector: compatible to system Storz, stepless illumination adjustment with mechanical diaphragm • System Acc. guideline Med. Prod. 93/42 EWG Class 1 Electromagn. compatibility: EN 60601-1 Classification: BF/CE mark Power connection: 100-250 V AC, 50-60 Hz, 400 VA • Dimensions/Weight Housing: 360 x 128 x 338 mm (W x H x D) Weight: 7.1 kg Camera head: 135 x 50 mm (L x ø) Camera cable: 3m Item numbers 95.1008x FlexiScope 180X-CC; 180 W Xenon LS. with Compact Camera, PAL 95.1008x.DIG FlexiScope 180X-CC; 180 W Xenon LS. with Compact Camera, PAL, USB 2.0, FlexiView 95.1009x FlexiScope 180X-CC; 180 W Xenon LS. with Compact Camera, PAL, anti-Moiré 95.1009x.DIG FlexiScope 180X-CC; 180 W Xenon LQ. with Compact Camera, PAL, USB 2.0, anti-Moiré, FlexiView NTSC versions available on request. The FlexiView software for simple image recording and storage is included in delivery of cameras with USB 2.0 interface. I-06 ACC 611
  28. 28. Light Source-Camera Unit FlexiScope 180X-301 - Light Source-Camera Unit FlexiScope 180X-301 - the combination, includes a fine adjustable 10 bit 1CCD camera and light intensity xenon light source. • Operation control White balance, window function, preset function with three selectable basic setups - all with OSD/LED indicator, contrast/brightness adjustment with OSD indicator • Camera controller Outputs: 1 x S-Video (Y/C), 1 x Video (FBAS) • Camera head Image sensor: 1/2" CCD Image resolution lines: 470 (H) x 420 (V) PAL 470 (H) x 350 (V) NTSC Image resolution act. pixels: 440,000 (PAL)/380,000 (NTSC) Light sensitivity: 2 Lx/f = 1.4 Endoscope coupler: Standard eye piece, detachable C-mount over adapter Focal length TV adapter: f = 30 mm integrated anti-Moiré filter • Disinfection/Sterilisation Camera head soakable in liquids, suitable for disinfection, compatible to Steris® • Data light source with LED indicator, lifetime (bulb) indicator Nominal output: 180 W xenon Colour temperature: 6,000 Kelvin Light output: 25 mio. Lux Lamp life: 500 h (average) Light guide connector: compatible to system Storz, stepless illumination adjustment with mechanical diaphragm • System Acc. guideline Med. Prod. 93/42 EWG Class 1 Electromagn. compatibility: EN 60601-1 Classification: BF/CE mark Power connection: 100-250 V AC, 50-60 Hz, 400 VA • Dimensions/Weight: Housing: 360 x 128 x 338 mm (W x H x D) Weight: 7.4 kg Camera head: approx. 140 x 60 mm (L x ø) Camera cable: 3m Item numbers 95.1005x FlexiScope 180X-301; 180 W Xenon LS. with Camera C1301, straight, PAL 95.1006x FlexiScope 180X-301; 180 W Xenon LS. with Camera C1301, bent, PAL 95.1007x FlexiScope 180X-301; 180 W Xenon LS. with Camera C1301, self-adjusted TV adapter, PAL NTSC versions available on request. ACC 612 I-06
  29. 29. Light Source-Camera Unit FlexiScope 180X-3CCD - Light Source-Camera Unit FlexiScope 180X-3CCD, the combination of a high intensity xenon light source and a fine adjustable 3-chip camera. To allow digital archiving of camera images, this unit is equipped with a modern USB 2.0 interface for direct connection to a standard PC. 3 preset programs - individually to costumize by user. White balance Function key • Operation control White balance, window function, preset function with three selectable basic setups - all in OSD menu modifiable, brightness adjustment with OSD indicator Camera head: white balance, function key • Camera controller Outputs: 1 x RGB Sub-D 1 x S-Video (Y/C) 1 x Video (FBAS) 1 x USB 2.0 1 x 3.5 mm cinch for remote control • Camera head Image sensor: 3 x 1/3" CCD Image resolution lines: 750 (H) x 430 (V) PAL 750 (H) x 350 (V) NTSC Image resolution act. pixels: 440,000 (PAL)/380,000 (NTSC) Light sensitivity: 5 Lx/f = 2.2 Endoscope coupler: Standard eye piece, C-mount, detachable Focal length TV adapter: f = 23 mm • Disinfection/Sterilisation Camera head soakable in liquids, suitable for disinfection, compatible to Steris® and Sterrad® • Data light source ON/OFF with LED indicator, lifetime (bulb) indicator, connector for light cable adapter system Storz, stepless illumination adjustment with mechanical diaphragm Nominal output: 180 W xenon Colour temperature: 6,000 Kelvin Light output: 25 mio. Lux Lamp life: 500 h (average) • System Acc. guideline Med. Prod. 93/42 EWG Class 1 Electromagn. compatibility: EN 60601-1 Classification: BF/CE mark Power connection: 100-250 V AC, 50-60 Hz, 400 VA • Dimensions/Weight Housing: 360 x 150 x 338 mm (W x H x D) Weight: 8.3 kg Camera head: 165 x 50 mm (L x ø) Camera cable: 3m Item numbers 95.1010x.DIG FlexiScope 180X-3CCD; 180 W Xenon LS. with Camera C33001, USB 2.0, FlexiView NTSC versions available on request. The FlexiView software for simple image recording and storage is included in delivery of cameras with USB 2.0 interface. I-06 ACC 613
  30. 30. TV Adapter TV Adapter for cameras with C-mount TV Adapter for FlexiScope C1301/180X-301 With C-mount for all camera heads and quick coupler Direct coupling to the camera modules C1301/180X- for all endoscopes with eye piece (ACMI/BS); 301 and all endoscope eye pieces; incl. focusing, with quick coupler and retaining screw. incl. focusing, with anti-fogging holes and retaining Low weight with anti-fogging holes. screw for endoscope eye piece, low weight. Sterilization: soaking and gas. Sterilization: Soaking and gas. Standard TV Adapter FlexiScope Camera TV Adapter * ** 95.2010s TV adapter: f = 25 mm 95.2011s TV adapter: f = 30 mm 05.0062s TV adapter: f = 18 mm ** 05.0067s.M2 TV adapter: f = 25 mm * 05.0064s.M2 TV adapter: f = 30 mm * 05.0066s.M2 TV adapter: f = 40 mm * Self-adjusted Camera TV Adapter for FlexiScope C1301/180X-301 Zoom TV Adapter This TV adapter avoids the problem of the „leaning image“ in case of rotated endoscope. With this With C-mount for all camera heads and quick coupler “Pendulum”- construction, the TV-adapter ensures an for all endoscopes with eye piece (ACMI/BS); always upright orientation picture, even if the end- incl. focusing, with quick coupler and retaining screw. oscope is turned during the procedure. Quick coupler Low weight with anti-fogging holes. with retaining screw. Sterilization: soaking and gas. „Pendolino“ 95.2014s Self-adjusted camera TV adapter f = 30 mm, only for camera head C1301/180X-301. 05.0063s Zoom TV Adapter f = 18 - 50 mm, with C-mount, Sterilization: soaking and gas. C - mount Adapter for FlexiScope C1301/180X-301 95.2012s C-mount Adapter for C1301/180X-301 Image size on the screen with 1/2'' CCD camera Image size on the screen with 1/3'' CCD camera ! ! ! ! ! ! ! ! f = 18 mm f = 25 mm f = 30 mm f = 40 mm f = 18 mm f = 25 mm f = 30 mm f = 40 mm standard standard Base: Endoscope Ø 4 mm Base: Endoscope Ø 4 mm ACC 614 I-06
  31. 31. Camera Cable 05.9105k Video Cable (FBAS) 2 m with BNC plug 05.9102k S-Video (Y/C) Cable 2 m with mini hosiden 05.9090s.v Remote control cable between camera remote output and video peripheral units 3.5 mm phone jack at cinch (RCA) plug I-06 ACC 615
  32. 32. Peripheral Units MediCapture MediCapture captures and stores digital images on USB flash drive from your existing camera equipment works with existing endoscopes, surgical microscopes, etc. System PAL and NTSC (switch selectable) Inputs/Outputs S-Video or composite BNC Power 100 - 240 V AC Foot switch (optional) Hands-free capture, standard 3.5 mm mini jack Media MediCapture brand USB flash drives (required) Image formats DICOM, DICOM True Color, JPG, BMP PCX color, PCX greyscale , Image size 800 x 600 pixels Environmental Storage: - 40° to + 85° Operating: - 20° to + 40° Dimensions (mm) 240 x 63 x 200 (W x H x D) Certifications UL, FCC, CE Kit contents MediCapture, USB flash drive, power cable, user guide Item numbers 05.9190v MediCapture 05.9191v USB MediCap100 extender stick 05.9192v Foot switch for MediCapture 05.9070v DVD Recorder DVO-1000MD-Sony 05.9180p Colour Video Printer UP21MD - SONY Recording system: DVD recording, Print technology: Colour thermo-sublimation NTSC/PAL switchable Resolution: 403 dpi (1664 pixels) Video recording format: MPEG-2 Paper size: A6 Playable media: DVD + RW Image storage: 4 image storage Video input: 2 x S-Video (Y/C, mini DIN) Remote control: 3.5 mm mini plug 2 x Video (FBAS, BNC) Video In-/Output: Video, S-Video, RGB Remote: 1x RS-232C Power consumption: 240 VA 2 x Stereo mini plug Power supply: 120/240V, 50/60 Hz 1 x USB 2.0 Dimension (Wx H x D): 212 x 125 x 395 mm Power supply: 100-240 V AC, 50/60 Hz Weight: approx. 6.5 kg Power consumption: 35 VA Safety tests: UL2601-1, CSA, Dimension (Wx H x D): 212 x 128,5 x 382 mm EN60601-1, CE Weight: 6 kg 05.9281r Paper + Toner for Sony UP21MD - SONY 1 Package = 240 sheets ACC 616 I-06
  33. 33. Monitors LCD Video Monitors 15''/ 19'' Daten 15'' 19'' Visible area 304 x 228 mm 376 x 301 mm Dimensions (Wx H x D) 385 x 309 x 80 mm 465 x 400 x 98 mm Weight 4.8 kg 6.8 kg Colours 16.8 mio. 16.8 mio. Greyscales 256 256 Resolution 1,024 x 768 XGA 1,280 x 1,024 SXGA Viewing angle (H/V) 170°/170° 170°/170° Brightness 430 cd/m2 350 cd/m2 Contrast ratio 500 : 1 650 : 1 Response time 10-16 ms 10-16 ms Nominal voltage display 16-24 VDC (100-240 V AC) 16-24 VDC (100-240 V AC) Power input 40 W 60 W Video through Yes Yes Input - Video (FBAS, BNC) - Video (FBAS, BNC) - S-Video - S-Video (Y/C, mini-DIN or 2 x BNC) (Y/C, mini-DIN or 2 x BNC) - Component Video - Component Video (RGB, 5 x BNC or HD 15) (RGB, 5 x BNC or HD 15) - VGA (VGA, HD 15) - VGA (VGA, HD 15) Output - Video (FBAS, BNC) - Video (FBAS, BNC) - S-Video (Y/C, mini-DIN) - S-Video (Y/C, mini-DIN) - Component Video - Component Video (RGB, 5 x BNC oder HD 15) (RGB, 5 x BNC oder HD 15) Overscan Yes Yes VESA compatible 100 100 Item numbers 05.9032m 15” LCD Video monitor with medical authorization, with RGB 05.9033m 19” LCD Video monitor with medical authorization, with RGB I-06 ACC 617
  34. 34. Software FlexiView - Software for Image Archiving Developed as a specially easy and user-friendly desktop. Picture recording per mouse click,alternative via camera function key live Open picture overview Video settings Program options Quad split view Main screen: Full screen view live video image, last 4 stored images, settings for folder, file name, file number. Description Opening the pictures with available image processing programs Standard version included in the delivery of cameras with USB 2.0 interface DirectX/Direct Show compatible Executable on WIN2000 (SP4) and XP (SP1) Remote control via camera function key (in connection with Schölly camera systems with dig. USB 2.0 output and PC 2 GHz or more.) FlexiView Video Grabbing System: Developed as accessory for all Schölly cameras without digital USB 2.0 interface. Item no. Description 95.2070.dig Smartbox, foot switch, video- /foot pedal connecting cable, USB cable, Driver software and FlexiView software ACC 618 I-06
  35. 35. Flexi Cart Flexi Cart For easy handling and for transport purposes, a multi functional OP-Cart - FlexiCart - is available. FCW.MED40.1 Flexi Cart consisting of: • Basis cart 40E/width 500 mm • 4 double free rotating rolls 100 mm • 1 layer with handle • 4 layers standard • 1 lockable drawer • 2 power profiles 40E • 1 multiplug socket 6 x • Surface RAL 7035 light grey • Decoration elements RAL 5012 light blue FCW.GH.1 FlexiCart gas bottle holder For lateral fixation of customary gas bottles with max. diameter of 145 mm. FCW.TT.1 FlexiCart option safety transformer • Isolating transformer 1,600 VA • ISO Max isolation keeper • Cold unit extension lead 8-fold with one POAG plug each and one fuse per socket instead of a normal extension lead • roll set Ø 125 mm, conductible 05.0700r.cord.cart Power connector cable Power connector cable between Schölly cameras, insufflators or light sources and the option safety transformer extension lead • Length 1.8 m • Straight I-06 ACC 619
  36. 36. Baskets / Sterisafe / Ocular Funnel Endoscope Baskets 02.0050a Sterisafe E42 Whether it is a matter of cleaning, sterilizing, storage or transport, the endoscope basket offers secure pro- tection for the sensitive endoscopes against damage. The endoscope baskets are made of chrome nickel steel, are electrolytically polished, free of burs manu- factured and have closed wire strap. The removable cover equipped with a special rotata- ble adapter made of high-grade synthetic material protects against self-opening. Plugged-on silicone store elements guarantee an opti- Dimension (mm): 440 x 107 x 71 mal fixation of your endoscopes during the washing (W x H x D) and sterilizing process. The outer contours of the basket are arranged with- Spare parts for Sterisafe: out overhang edges and create excellent conditions 02.0060a Silicone-insert (7- pieces) for shrink-wrap of baskets. A clean solution for stora- ge and transport of endoscopes after sterilization. 02.0070a Filter 02.0080a Date insert 02.0090a Seal with indication point (2,000 - pieces) 02.0010a Endoscope Basket with cover 02.0091a Safety lead seal 02.0095a PST Steritray + Silicone mat for Arthroscopes and Sinuscopes Dimensions (mm): 290 x 80 x 52 (W x H x D) 02.0020a Endoscope Basket with cover for flexible mini endoscopes Dimensions (mm): 265 x 45 x 160 (W x H x D) Eye Pieces for Laparoscopes, Cystoscopes, Hysteroscopes etc. Dimensions (mm): 460 x 80 x 52 (W x H x D) 02.0030a Endoscope Basket with cover 21.0550a Eye Piece for endoscopes of Ø outer: 2.7 mm - 6.5 mm Ø 18 mm 21.0551a Eye Piece for endoscopes of for Laparoscopes, Cystoscopes, Ø outer: 2.7 mm - 6.5 mm Hysteroscopes etc. Ø 20 mm Dimensions (mm): 670 x 80 x 52 21.0560a Eye Piece (W x H x D) for endoscopes of Ø outer: 10 mm Ø 19.2 mm ACC 620 I-06
  37. 37. FlexiFairplay Worldwide Service Germany-trained national competence with Schölly technology Service Denzlingen I-06 SER 701
  38. 38. FlexiFairplay Worldwide Service Your advantages with a „Schölly licensed Service Partner“: • Same quality standards worldwide • Centralized spare parts management for service centers • Online know-how transfer by Schölly • Identical test devices, supplied by Schölly • Centralized data base with technical specifications and working instructions for use • Training for all service partners in Denzlingen/Germany Service Centers USA Saudi Arabia Korea Russia India China Australia Japan Brazil SER 702 I-06
  39. 39. FlexiFairplay Service is our obligation to you As a manufacturer we have the possibility to offer a comprehensive service range, which is more than an common repair. At Schölly Fiberoptic you decide which of our service versions should be applied at the repair of your endoscopes. ClassicRepair • Repair if cheaper and safe, • Exchange if necessary FlexiFairplay FlexiLine 8 Best Prices 8 Market Share 8 Win-Win Situation A new weapon to win market share ConsiStock • Winning through response time • Immediate exchange is key to success Have in mind: 70% of the future endoscopy business will be service. I-06 SER 703
  40. 40. FlexiFairplay ClassicRepair ClassicRepair Repair if cheaper and safe - Exchange if necessary! „ Schölly repairs or exchanges 90 % of all rigid medical scopes “ With our well established ClassicRepair program you can offer your customers a fair and transparent service. You may rest assured, 90 % of all rigid surgical endoscopes can be repaired or exchanged. With the experience of 60,000 repaired scopes we really know what we are talking about. Send us the damaged scopes and we offer you: Repair if cheaper and safe Exchange if necessary Four different repair levels keep the program easy and straightforward. Detailed cost estimate reports and service reports with images before / after repair as well as our quality management system gives you full traceability of all repairs. And we guarantee fast transactions, local pricing due to more than 20 licensed or Schölly owned repair centers and the ambition to have the same quality standard world- wide. Don't wait and leave the service business to the others Start today with the ClassicRepair program! Come and fly with us! I-06 SER 709
  41. 41. FlexiFairplay ClassicRepair ClassicRepair (Nose-Pharyngoscope/Uretero-Renoscope) Repair if cheaper and safe - Exchange if necessary! „ 70 % of future endoscopy business will be service “ With our well established ClassicRepair program you can offer your customers a fair and transparent service. With the experience of 60,000 repaired scopes we really know what we are talking about. Send us the damaged scopes and we offer you: Repair if cheaper and safe Exchange if necessary Four different repair levels keep the program easy and straightforward. Detailed cost estimats and service reports with images before / after repair as well as our quality management system gives you full traceability of all repairs. And we guarantee fast transactions, local pricing due to more than 20 licensed or Schölly owned repair centers and the ambition to have the same quality standard worldwide. Don't wait and leave the service business to the others Start today with the ClassicRepair program! Come and fly with us! I-06 SER 711
  42. 42. FlexiFairplay ClassicRepair ClassicRepair (Nose-Pharyngoscope/Uretero-Renoscope) Repair if cheaper and safe - Exchange if necessary! Maintenance Repair save and Repair save and Repair or Repair levels Schölly cheaper cheaper exchange Exchange Nose-Pharyngoscope Level 0 Level A Level B Level C Action Cleaning and sterilization into new Schölly Nose-Pharyngoscope Incoming inspection & damage analysis Repair of fiber optics (distal and proximal) You receive a Replacement of eye piece brand new Schölly endoscope suitable Replacement of ocular/ for your diaphragm instruments Replacement of objective Replacement of image guide incl. objective with a warranty of Replacement of tubing 12 months. Replacement of tip mechanics Replacement of fiber optics Your defect or old New adjustment according scope is accepted in specification payment. Leak test Service Report & Warranty Certificate Maintenance Repair save and Repair save and Repair or Repair levels Schölly cheaper cheaper exchange Exchange Uretero-Renoscope Level 0 Level A Level B Level C Action into new Schölly Cleaning and sterilization Uretero-Renoscope Incoming inspection & damage analysis You receive a Cleaning and polishing brand new Schölly of surface endoscope suitable Cleaning of fiber optics, for your glueing and polishing instruments Dismantling and cleaning of ocular system Replacement of eye piece with a warranty of Replacement of ocular/ 12 months. diaphragm Replacement of image guide incl. objectives Your defect or old Replacement of shaft scope is accepted in mechanics incl. fiber optics payment. New adjustment according specification Compatible to Leak test Schölly and Wolf. Further brands in Service Report & preparation. Warranty Certificate SER 712 I-06
  43. 43. Prevention of Damage The consideration of critical areas of an endoscope helps to prevent damages. 1 Critical Area 1 Distal End 2 Critical Area 2 Endoscope sheath 3 Critical Area 3 Changeover Sheath/Main body I-06 SER 719
  44. 44. Prevention of Damage Critical Areas of an Endoscope Critical parts of a scope are the optical systems, which have to withstand heavy mechanical stress depending on application: Examples: Critical Area 1: Distal end of the endoscope In this area defects can occur by shaver use and HF powered systems if these are in contact with the endoscope. This is often the case in orthopedic and gynecological applications. Critical Area 2: Endoscope sheath Sometimes heavy damages occur at the endoscope sheath if the scope is wrongly inserted in a working channel. The longer the working length of the endoscope is, the higher the risk is for such damage. Damage often occurs when the scope is inserted into the sheath. If the inser- tion is not done axially but radially to the optic sheath, care should be taken during this procedure. Critical Area 3: Changeover sheath/Main body It is in most cases a consequence of the above-mentioned problem (compare critical area 2). Additionally compressions of the sheath to the main body occur what is often to attribute to improper use during decontamination. SER 720 I-06
  45. 45. Assembly of Light Guide Cable Light Guide Cables Schölly light guide cables are not glued at the light source end but compressed and optically treated. They are able to withstand breakdown voltages of 5 kV and temperatures up to 300°C. Optical fibers Silicone tube Steel thread Nylon protection Bending radius Chain reactions may occur - especially if the light entrance area is damaged. Example: The capillary space between the fibers of the most used endoscopes are polished, ground and filled in with the appropriate medical adhesive. Cleaning with common cleaning procedures ==> Washouts in the spaces between the fibers ==> Extension of the surface at the point of incidence ==> Disproportionate heating at the input through the extended surface ==> Burns at the distal end with significant loss of transmission and change of colour ==> Gas evolution of adhesive residues I-06 SER 721
  46. 46. Reviewing of Light Guide Cable Picture of a light guide at delivery Gives optimum of illumination Sectional fiber breakage (black faces) Reduced illumination Distributed fiber breakage Most of the fibers are broken Out burned light guide Fibers are melted = unusable We recommend the exchange of a light guide as soon as more than 50% of the fibers are broken. SER 722 I-06
  47. 47. Technology Sterilization Sterilization - Our Main Competence All Schölly endoscopes with AUTOCLAVE mark are according to WHO-recom- mendation suitable for steam sterilization - 18 min. at 134 °C/273 °F. Since the outbreak of the Creutzfeldt-Jakob disease, many scientists have been busy to find out how to avoid the risk of transmission of the Spongiform Encephalopathy (Creutzfeldt-Jakob Disease, or BSE) during invasive operations particularly in the field of neurosurgery, spinal surgery or in case of oph- thalmological surgical operations. The World Health Organisation (WHO) has now published a report with recommendations regarding the handling of surgical instruments and endoscopes in view of ste- rility (WHO/CDS/CSR/APH/2000.3 http://www.who.int/csr/en). According to this report, it is advisable to use disposable material. If not possible or too costly, the autoclaving and chemical sterilization are considered to be most effective methods in order to main- tain the heat resistance and reusability of endoscopes. In this context, the mandatory holding time with a defined maximum temperature (18-20 minutes with 134 °C) is a new and technically very com- plex requirement for rigid endoscopes. Schölly Fiberoptic GmbH, having its core competence exactly in this field, offers now all autoclavable rigid endoscopes with validation concerning this new requi- rement of 18-20 minutes with a temperature of 134 °C. As an additional innovation Schölly offers as one of few suppliers autoclavable, flexible endoscopes with a minimal diameter of 0.35 mm up. These endoscopes have an optical system with 3.000 - 50.000 pixels and additional illumination fibers for illumination. These have been specified according the requirements of the WHO. Reconditioning Compatibility of Schölly - Endoscopes New sterilization methods require a constructive consideration in scope manufacturing. In times of increased infections new sterilization methods have been developed to assure a safe and fast sterilization process. Those sterilization methods which do not have the major disadvantages of gas sterilization (residues, environmental compatibility), are finding more and more acceptance in hospitals. The adavantages are evident: • Short cycle times (usually < 75 minutes) • No cooling cycles • No toxic residues, therefore no burden for the persons in charge • Remaining humidity < 5 %, not corrosive • Virucide, sporicide, tuberculocide, bacteriozide, fungizide • Suitable for thermolabile materials, as temperature is < 56 °C • Process controlled Schölly endoscopes have shown their material compatibility for these application methods by passing several tests. The effects of the sterilizing process have to be documented by the user. TEC 800 I-06
  48. 48. Technologie Sterilization STERIS® from Steris Corporation STERIS® is a „cold“ liquid sterilization. Acetic peroxide is mixed with sterile water, the instruments to be sterilized are washed with solvents. After twelve minutes of dipping the instrument in the sterili- zing solution, the solution is pumped out and the instrument is rinsed with sterile water four times. The working channel of rigid/flexible endoscopes can be attached to a pressurized fitting for sterili- zation. Precise information on www.steris.com STERRAD® from Johnson & Johnson STERRAD® is a low temperature-plasma sterilization. The hydrogen peroxide dioxide is transported from the magnetic field to the plasma phase. One cycle consists of following phases • Phase of vacuum: evacuate up to a pressure of 0.3 mbar. • Phase of injection: 2 ml liquid H2O2 are injected into the vacuum. • Phase of diffusion: app. 50 minutes are necessary for the homogeneous distribution of hydrogen peroxide in the chamber, the pressure increases to 7 - 11 mbar. • Phase of plasma (app. 20 Min.) : Production of primary plasma; secondary plasma follows; actual phase of sterilization; end products are water (H2O) and oxygen (O2). • Phase of pressure compensation: Adjustment of atmospheric pressure in the chamber. The methods of STERRAD® and STERIS® help to avoid high temperatures on optical systems. This results in a very gentle sterilization method. Nevertheless, the use of peracedic acid as well as hydro- gen peroxide may cause a more intensive wear of the endoscope surfaces (washout, bleeching effects). However, these effects do not have any influence on the lifetime of the endoscopes. It is main- ly a „cosmetical“ effect. These effects have such a minor influence on the lifetime of the endoscopes compared to the effects of high temperature methods. The effecs of the sterilizing process have to be documented by the user. All Schölly endoscopes are material compatible regarding following process: • Soaking in disinfectant which is approved for instrument disinfection • Gas sterilization: formaldehyde, ethylene oxide • STERRAD® und STERIS® methods • Autoclavation 18 - 20 minutes at 134 °C according to WHO-recommendation, see label I-06 TEC 801
  49. 49. Technology Endoscopes Assembly of Endoscopes An endoscope is an optical instrument which is equipped with a light source and other optical devi- ces. It allows to illuminate and to view a visceral cavity or a hollow organ. ocular objective (image enlargement) Insulating synthetic ocular part. Stainless steel body. laser-welded fiber cone for light tight connections amplification light guide fibers • large perspective • diameter: 0.03 mm Image transfering rod lens stainless steel body, no coating Objective (picture taking) TEC 802 I-06
  50. 50. Technology Why Schölly Endoscopes? 6 convincing reasons for Schölly Endoscopes 1 Proximal and distal saphir-window, scratch-resistant, no glass corrosion 1 2 2 Scope body and sheath are made of stainless steel, no coating 3 4 3 Laser-welded optical centering = hermetic sealing between optics/fiber optics 4 Laser-welded connection between body and outer tube 5 Airspaces filled with drying agent = less humidity, longer service life 5 6 Service-friendly objective; 6 most parts can be reused 1 I-06 TEC 803
  51. 51. Technology Side View Objectives Side view objectives Besides endoscopes with direct view objectives (0°), some applications need 10°, 30°, 45°, 70°, 90° or 110° side view. For side view objectives, complex prism-systems are necessary. Please see the drawings of a 30° objective in detail: 30 °O bj ec tiv e TEC 804 I-06
  52. 52. 3D - Robot Surgery „Da Vinci® “ System The complete visualization part for the „Da Vinci® “ robot system has been developed in close cooperation between Intuitive and Schölly. Contents of this Schölly Solution 3D - Endoscope • Two single optical channels. • High resolution, low image distortion. • Homogeneous 4-point illumination with twin adaptation for light guide cables. • All mechanical parts in stainless steel, all connecting parts laser welded. • The optical system is calculated to see even smallest blood vessels crystal clear. 3CCD Cameras & TV adapter • 2 x 3 CCD Cameras for PAL or NTSC • The TV adapter has a motor driven zooming device. All INDIA Distributor: ENDOSYS INTERNATIONAL Mumbai +91-9820422965 Ahmedabad TEC 806 I-06 +91-9824269063

×