Office BuildingsSolutions for energy efficient, flexible andproductive work-placesWhere I spend most of my active life
Solutions for office buildings    Offices account for more         At Schneider Electric, we    than 30% of total commerci...
50 kWh/m                                           2per yearOur energy management solutions combined with appropriate buil...
4
Solutions for office buildingsA new way of thinkingabout energyThe amount of energy an office building uses is about moret...
A successful project is    one that is delivered    on time and on    budget. Our solutions    for office buildings    can...
Optimize ROI andoccupant experienceOffice buildings come in a variety of shapesand sizes. They also offer different levels...
Up to    - 30 %     Our solutions     contribute to more     efficient building     operation that can     reduce energy  ...
Active energy efficiency and environmentally-sound business practicesKnowledge is power:the power to saveYou can’t manage ...
Consume smarter     and consume less     Track and manage consumption                        Optimise building energy cons...
Buy energy at prime rates by using                      targeted information to select the best utility rate              ...
Sustain maximum     performance levels     Sustaining maximum performance over long             Our active energy-efficien...
Implement environmentally-                                  sound practices                                  A building’s ...
- 30 %      Reduce      set-up and      reconfiguration      time by 30% thanks      to our flexible,      prefabricated  ...
Flexible, upgradeable buildingsPut your office buildingto work – full timeA fully-occupied building is a profitable buildi...
You can increase     occupancy rates     by making your     building safer and     improving occupant     experience16
Change your installation at                                                     key designa moment’s notice               ...
18
Safer, more efficient buildingsFrom always ”on”to ”on demand”Safe, efficient office buildings optimise temperature, lighti...
keys to     productivity     > Control of the work environment:     heating, cooling, air, lighting     > Secure, reliable...
Improve safety andsecurityEnsure a high-availability power supplyfor lighting and safety systems, data networksand sensiti...
Choosing innovative solutions     that add value                                                          3               ...
4                             Technical facilities on each floor                             Distribution board s n l     ...
Best-in-class solutionson which you can count on            Schneider Electric solutions:            > Minimise your capit...
Upcoming SlideShare
Loading in …5
×

Office-building-catalogue-India

658 views

Published on

Published in: Technology, Business
0 Comments
1 Like
Statistics
Notes
  • Be the first to comment

No Downloads
Views
Total views
658
On SlideShare
0
From Embeds
0
Number of Embeds
3
Actions
Shares
0
Downloads
24
Comments
0
Likes
1
Embeds 0
No embeds

No notes for slide

Office-building-catalogue-India

  1. 1. Office BuildingsSolutions for energy efficient, flexible andproductive work-placesWhere I spend most of my active life
  2. 2. Solutions for office buildings Offices account for more At Schneider Electric, we than 30% of total commercial deliver energy management building energy use expertise that can help your organization optimize energy consumption2
  3. 3. 50 kWh/m 2per yearOur energy management solutions combined with appropriate buildingdesign improve building operation and cut energy consumption by up to50 kWh/m2 per year – for energy-positive buildings, it is possible to achievezero consumption Make the most of your energy 3
  4. 4. 4
  5. 5. Solutions for office buildingsA new way of thinkingabout energyThe amount of energy an office building uses is about morethan just utility bills. What if you could leverage smarter buildingenergy management as a key differentiator for your business?Not only is this possible – in today’s fiercely competitive marketit is crucial. Your building energy investments must:> Ensure excellent financial returns.> Provide an attractive, well-designed working environment thatcontributes to greater employee efficiency.> Comply with current and – ideally – future legal and regulatoryrequirements.> Support Corporate Social Responsibility (CSR 2001) objectives.The capacity to meet these expectations has a direct impacton the business value your organization can deliver to all of itsstakeholders. 10 to 15 kg CO2 / 3 min The carbon dioxide emissions of a 10,000 m2 office building 5
  6. 6. A successful project is one that is delivered on time and on budget. Our solutions for office buildings can help you reduce capital expenditures.6
  7. 7. Optimize ROI andoccupant experienceOffice buildings come in a variety of shapesand sizes. They also offer different levels ofamenities. However, all office buildings mustmeet a common set of requirements:> Optimise energy efficiency, e.g. byadjusting energy consumption to actualneeds.> Be flexible enough to allow office space tobe restructured as old occupants move outand new ones move in.> Improve the working environment andquality of life.> Comply with health, safety and energystandards and regulations.Choose solutions thatmeet your unique needs> Secure, reliable power supply systems.> Energy efficiency audits and assessments.> Energy consumption tracking and analysis.> Optimised control of heating, ventilation, Optimise yourair conditioning, lighting and blinds. capital expenditures,> Secure, supervised access to buildings. reduce your operating> Fire safety systems. costs and increase> Integrated voice/data/image networks. the business value your office buildings deliver 7
  8. 8. Up to - 30 % Our solutions contribute to more efficient building operation that can reduce energy consumption by up to 30 %.8
  9. 9. Active energy efficiency and environmentally-sound business practicesKnowledge is power:the power to saveYou can’t manage what you can’t measure. Rising energy costsand environmental awareness have spurred investors, developers,builders, operators and occupants to make their buildings more energyefficient. But to truly optimise building energy consumption, you needdetailed, accurate data about how that energy is being used. 70% of the energy consumed by an office building is used for lighting and HVAC 9
  10. 10. Consume smarter and consume less Track and manage consumption Optimise building energy consumption to detect opportunities for savings There are several ways to strike the best balance Installing tracking equipment and analysis between occupant experience and energy software can provide you with valuable consumption: information on building operations and > Use reactive energy compensation to improve energy consumption. Setting up and analysing the quality of the energy used and get the best energy indicators is an effective way to pinpoint possible utility rates. consumption peaks and energy losses. > Install variable-speed drives on pumping and You can then take targeted corrective measures ventilation systems. and assess their impact. > Manage indoor and outdoor lighting systems; install manual switches, timers and light or motion detectors. A kWh/m2/year > Manage and integrate heating, ventilation, air conditioning and window-blind operation. B > Manage heating, ventilation, air conditioning C and window-blind operation independently, D zone by zone, depending on actual occupation, exposure, etc. E > Improve power supply reliability and security F by correcting the power factor and reducing G harmonics.10
  11. 11. Buy energy at prime rates by using targeted information to select the best utility rate on a given day. > Install hardware and software to automate consumption tracking. > Monitor consumption logs and profiles. > Predict energy demand. > Analyse utility rates and generate virtual use scenarios to assist in decision-making. > Consider the possibility of consolidating consumption data from several buildings. > Negotiate rates with utilities:50% • Based on the combined consumption of several buildings. • Avoiding consumption peaks by shutting down pre-selected equipment to reduce load.Variable-speeddrives for HVAC and Use renewable energy resourcespumping equipment to produce electricity, by investing in solar panels,can reduce energy for instance.consumption by50% > Supply, manage and secure the energy your buildings need. 11
  12. 12. Sustain maximum performance levels Sustaining maximum performance over long Our active energy-efficiency solutions incorporate periods of time is a real challenge. Buildings various levels of service from simple audits to and insulation materials age, office uses change comprehensive Energy Efficiency Contracts. and occupants tend to reduce performance These contracts include an obligation to through day-to-day habits like changing air generate savings that will pay for some or all conditioning settings or forgetting to turn off of the building improvements made. lights, etc. However, there are solutions that can help you to improve performance. > Set up management tools to track and analyse data. > Carry out scheduled maintenance. > Keep upgrades consistent throughout the building’s lifetime. > Provide training on products and systems.12
  13. 13. Implement environmentally- sound practices A building’s environmental impact and carbon footprint must be taken into account from the design stage and at each phase of construction. At Schneider Electric, we integrate eco-design into all of our solutions: > Lower building energy consumption. > Recyclable materials. > Lower volume and/or weight to lessen impacts related to transport and end-of-life waste quantities. > Manufacturing processes that generate less pollution. Our solutions also comply with25  % international standards (RoHS Directive) concerning the disposal of hazardous waste in obsolete electrical and electronic equipment.The difference between theenergy efficiency calculated We also offer end-of-lifetime equipmentat the design stage and the management and disposal solutions.actual efficiency during usecan be up to 25%. The onlyway to reduce this differenceis to monitor energy efficiencyon a regular basis. 13
  14. 14. - 30 % Reduce set-up and reconfiguration time by 30% thanks to our flexible, prefabricated solutions.14
  15. 15. Flexible, upgradeable buildingsPut your office buildingto work – full timeA fully-occupied building is a profitable building. To maximise occupancyrates, office buildings must be flexible enough to be restructured quicklyand inexpensively. Smart office building design allows partition walls to bechanged quickly and easily, new safety functions and facilities to be added,workstations to be reorganised and power, data and lighting networks to bemodified – effectively putting your building to work full time. Build better and faster Use prefabricated equipment that is easier to connect, reducing construction delivery times. Examples include modular electrical switchboards, prefabricated wiring systems, pre-wired power sockets and data outlets, etc. Simplify the integration of all technical facilities by using open, standard communication protocols. In today’s buildings, electrical wiring must be integrated into Building Management Systems (BMS) from the very beginning. 15
  16. 16. You can increase occupancy rates by making your building safer and improving occupant experience16
  17. 17. Change your installation at key designa moment’s notice principles forModular electrical installations flexible offices> Simplify future modifications by supplying the premises with electricity > Separate areas depending onthrough prefabricated wiring systems, with regularly distributed how they are to be used: forconnectors. example, separate technical facilities for common areas> Facilitate access to power sockets and network sockets by using from those for rental unitsperipheral cable trunking, floor-level boxes and posts that can be easilymoved or upgraded – or build sockets directly into office furniture. > Separate the fixed parts related to the building from changeableData networks accessible anywhere in the building parts related to the occupants> Installing voice/data/image consolidation points on the floor deck > Separate areas into small modulesmakes network sockets easy to reconfigure. of 25 m2 to 50 m2, each with its own electrical supply, its own system toOpen-ended Building Managment Systems (BMS) manage lighting and air-conditioning, and its own utility bills. Depending on> Using open-ended, standard protocols means that hardware, software occupant needs, modules may beand integrating systems can be extended or modified at will. combined in units of varying sizes.Fully reliable energy cost breakdown > Apply the same design principles to all technical facilities: power> Breaking down consumption by tenant and usage (lighting, HVAC, distribution, tracking, heating,etc.) provides detailed information according to the surface areas ventilation, air conditioning,occupied. lighting, fire safety, access control, Building Management Systems, data networks, etc. 5 years On average, occupants move to new premises or make significant changes to their existing premises (moving partition walls, converting individual offices into open-plan offices, etc.) every 5 years 17
  18. 18. 18
  19. 19. Safer, more efficient buildingsFrom always ”on”to ”on demand”Safe, efficient office buildings optimise temperature, lighting, ventilation andnoise and provide convenient access to various networks when and wherethey are needed. They also guarantee the safety of employees and thesecurity of property and data. Making it easy for building occupants to useenergy more efficiently can have a positive impact on comfort, safety andproductivity – not to mention your bottom line. Make offices easier to use Regardless of how each office floor is organised, our solutions guarantee that each workstation will be close to wall sockets, voice/data/image connections and HVAC and lighting controls. Bring controls closer to users, and provide climate control in the office or a particular area through the use of multiple temperature, light, motion and CO2 detectors. Integrate power and network sockets discreetly into walls, floors or furniture using removable modules. A wide range of equipment and designs are available offering up to six functions conveniently grouped together at the same access point. Place flexible, easily adjustable connection boxes and posts near meeting tables and offices. Maintain constant lighting levels by adjusting lighting intensity according to changes in natural light.+ 2 %Well-designedand comfortableoffices can increaseemployee productivityby 2% 19
  20. 20. keys to productivity > Control of the work environment: heating, cooling, air, lighting > Secure, reliable access to electricity > Access to data > Safety and security: access, intrusion, fire > Occupant health 99 % By having Schneider Electric coordinate electrical protection and secure power supplies for your building, you can achieve service continuity of 99%20
  21. 21. Improve safety andsecurityEnsure a high-availability power supplyfor lighting and safety systems, data networksand sensitive equipment such as lifts. The powersupply is only interrupted in the event of anextreme risk thanks to coordinated controlgearand protection equipment.Protect occupants and visitors fromelectrical hazards. Total safety is guaranteedthrough differential protection, preventing anyrisk of electrocution.Integrate building security into a solutionthat can combine up to five essential functions:access control, intrusion alarm, fire alarm, CCTVand safety lighting. In the case of fire detection,for example, the CCTV system will displayimages of the location where the alarm has beentriggered. 21
  22. 22. Choosing innovative solutions that add value 3 Solar panels UPS, protection, network coupling l Source management l l Energy efficiency s Flexibility 2 n Productivity and safety Heating, ventilation, air conditioning Variable-speed drives on motors l 3 Control and monitoring l 2 4 2 1 Offices, open spaces, meeting rooms 4 Power sockets s n VDI network sockets s n HVAC control l n Control of lighting and roller blinds l n Emergency lighting n Fire safety n Access control n 4 2 9 Electrical room Medium-voltage incoming station n l Low voltage distribution board n l Energy consumption tracking l Reactive energy compensation l Management of harmonics l22
  23. 23. 4 Technical facilities on each floor Distribution board s n l Energy tracking per use and per tenant l s Individual invoicing l s Prefabricated electrical distribution equipment s VDI dispatching racks s n VDI Distribution s n Access control n Secure power supply (UPS) n 5 Services Energy efficiency audit l Audit of equipment and systems installed l Energy Efficiency Contract l Energy consumption tracking l 1 6 Car park and surrounding areas Access control n Lighting control n l 1 Surveillance n Ventilation and air extraction l 6 1 58 9 7 8 Building management 7 system Energy consumption Control room tracking l Access control n Supervision l Video surveillance n Fire safety n 23
  24. 24. Best-in-class solutionson which you can count on Schneider Electric solutions: > Minimise your capital expenditures and operating costs. > Are built on the best-performing products and equipments in the market. > Are based on certified architectures. > Use open-ended, interoperable communication protocols. > Are associated with dedicated services covering the entire life-cycle of the building. > Meet pre-defined performance criteria. > Are designed to be deployed by building energy professionals. > Are consistent with environmentally- sound and sustainable business practices. > Our solutions are available wherever you need them: the products and equipment we use are sold in more than 130 countries. For more information visit our website at: www.schneider-electric.co.in Schneider Electric India Pvt. Ltd. (A 100% subsidiary of Schneider Electric Industries SAS) Corporate office : A-29, Mohan Co-operative Industrial Estate, New Delhi-110044. Tel: 011-39404000. Fax: 41678010/11 Customer Care Centre: Toll Free: 1800 111 341 (BSNL/MTNL), 1800 103 0011 (Airtel) Phone: +91 11 4168 2434/35, email: in-care@in.schneider-electric.com, website: www.schneider-electric.co.in

×