  1. 1. ACTIVITY NAME Vapor Intrusion Mitigation Former Naval Air Station Moffett Field Restoration Advisory Board Meeting May 11, 2017 Wilson Doctor Navy Project Manager
  2. 2. 5 BRAC Program Management Office. Vapor Intrusion Mitigation Schematic of Vapor Intrusion Pathway
  3. 3. 6 BRAC Program Management Office. Vapor Intrusion Mitigation Methods Vapor Intrusion Mitigation Methods – Eliminate preferential pathways – Increase ventilation inside the building – Active sub-slab ventilation (depressurization)
  4. 4. 7 BRAC Program Management Office. Vapor Intrusion Mitigation Methods Eliminate Preferential Pathways – Fill subsurface vaults – Seal cracks/expansion joints in floor slabs – Seal pipe penetrations/floor drains Sealing floor cracks Sealing floor drains
  5. 5. 5 BRAC Program Management Office. Vapor Intrusion Mitigation Schematic of Vapor Intrusion Pathway
  6. 6. 6 BRAC Program Management Office. Vapor Intrusion Mitigation Methods Vapor Intrusion Mitigation Methods – Eliminate preferential pathways – Increase ventilation inside the building – Active sub-slab ventilation (depressurization)
  7. 7. 7 BRAC Program Management Office. Vapor Intrusion Mitigation Methods Eliminate Preferential Pathways – Fill subsurface vaults – Seal cracks/expansion joints in floor slabs – Seal pipe penetrations/floor drains Sealing floor cracks Sealing floor drains
  8. 8. 8 BRAC Program Management Office. Vapor Intrusion Mitigation Methods Increase Ventilation Inside the Building – Fresh air intake – Increased air exchange rate
  9. 9. 9 BRAC Program Management Office. Vapor Intrusion Mitigation Methods Active Sub-slab Ventilation – Sub-slab depressurization system creates a negative pressure field below the building preventing soil gas from entering the building Schematic Sub-Slab Depressurization System Sub-Slab Depressurization Blower and Vent
  10. 10. 10 BRAC Program Management Office. Confirmation Sampling ROD Amendment for the Vapor Intrusion Pathway (EPA, 2010) for long-term exposure Chemical of Concern Indoor Air Cleanup Level (µg/m3) Commercial Trichloroethene (TCE) 5 Perchloroethylene (PCE) 2 cis-1,2-Dichloroethene 210 trans-1,2-Dichloroethene 210 Vinyl Chloride 2 1,1-Dichloroethane 6 1,1-Dichloroethene 700 Following implementation of mitigation measures, conduct air sampling to verify effectiveness.
  11. 11. 11 BRAC Program Management Office. Current Status and Schedule • Vapor Intrusion Mitigation Work Plan – Draft submitted March 17, 2017 – Final scheduled for Summer 2017 • Vapor Intrusion Mitigation Field Work – Scheduled for Fall 2017 through Spring 2018 • Completion Report – Draft scheduled for Summer 2018 – Final Scheduled for Winter 2018
  12. 12. 12 BRAC Program Management Office. Vapor Intrusion Mitigation QUESTIONS ?

×