Sterilization

1,371 views

Published on

Published in: Health & Medicine
1 Comment
1 Like
Statistics
Notes
  • SO GOOD NIC WORK
       Reply 
    Are you sure you want to  Yes  No
    Your message goes here
No Downloads
Views
Total views
1,371
On SlideShare
0
From Embeds
0
Number of Embeds
862
Actions
Shares
0
Downloads
0
Comments
1
Likes
1
Embeds 0
No embeds

No notes for slide

Sterilization

  1. 1. OUR STERILIZATION STANDARDS For 25years, we have cared for you!!
  2. 2. 25 years of caring.At Pradhan Dental Centre; we follow:1. International standards of sterilization,2. Ethical guidelines to deliver assured quality sterilization
  3. 3. OUR STERILIZATION CERTIFICATIONS: OHSAS 18001 VERTIFIED It oversees safety standards in sterilization & disinfection & ensures safety to our patients and staff.
  4. 4. WE ARE ALSO ISO 14001 & ISO 19001: 2008 CERTIFIED ISO 14001 CERTIFIED ISO 19001: 2008It monitors environmental It maintains & establishes standards quality management systems
  5. 5. Sterilization room Juhu
  6. 6. Sterilization room Bandra
  7. 7. Need for sterilizationMinimal bacterial counts are what weaim for and in the interest of bestpatient care, international standardsfor sterilization are followed to preventthe spread of infections.
  8. 8. Our goals include:1. Elimination of spread of infections such as Hepatitis B and HIV viruses2. Patient safety3. Healthcare workers safety
  9. 9. All the water used for dental treatment is of the highest standard since it is treated as follows before use. TAP WATER AQUAGUARD TREATED BOILED BOTTLED TESTED FOR MICROBES
  10. 10. RELIGARE WATER TEST REPORT - JUHU
  11. 11. RELIGARE WATER TEST REPORT - BANDRA
  12. 12. Sterilization procedure for Dental instruments:STAGE 1:Soaking:After use, all the instruments from eachpatient are dipped in an antisepticsolution. This ensures safety of both thepatient and the healthcare worker.STAGE 2:Scrubbing:All instruments are scrubbed usingautoclaved brushes to remove the debris.
  13. 13. STAGE 3:Ultrasonic water bath:The instruments are kept in anUltrasonic cleaner to shake off all thedebris.STAGE 4:Packaging:All instruments are packed insterilization rolls and heat sealed.
  14. 14. STAGE 4:Autoclaving:i. International standards require the use of a Class B autoclavei. A Prion cycle at 134°C is used by us for all surgical instruments.ii. A validation of every sterilization cycle is performed with maintenance of all records. Validation indicator Our clinic’s – strip Class B autoclave
  15. 15. STAGE 5:Storage:Instruments are packed and stored along with theirvalidation indicator strip.
  16. 16. STAGE 6:Before use all stored instruments are checked for dateof sterilization and santity of heat seal.
  17. 17. Our Sterilization certifications:At Pradhan Dental Centre, we constantly strive toensure SAL (Sterility Assurance Levels) in tandem withall the International standards.Pradhan Dental Centre is one of the only clinics withthe OSHAS 18001 certification (Occupational Health& Safety Management system) that ensures safety ofthe patients and the healthcare workers

×