  1. 1. POWER ELECTRONICAL Oil Testing Experts http://www.powerelectronical.com/   Transformer Oil Testing   Oil suffers from electrical and mechanical stresses while a transformer is in operation. In addition there are contaminations caused due  to  chemical  interactions  with  windings  and  other  solid  insulations,  catalyzed  by  high  operating  temperature.  As  a  result  the  original  chemical properties of Transformer Oil changes gradually, rendering it ineffective for its intended purpose after many years. Hence this  oil  has  to  be  periodically  tested  to  ascertain  its  basic  electrical  properties,  and  make  sure  it  is  suitable  for  further  use  or  necessary  actions like filtration/regeneration has to be done.      Power Electronical  Transformer Oil Testing Laboratory (TOTL)    PE‐TOTL  is  India’s  leading  private  laboratory  for  Transformer  Oil  testing.  It  is  located  in  the  same  premises  as  the  HQ  office,  and  this  allows  for  constant  supervision  and  monitoring  of  test  methods  and  testing  procedures,  and  constant upgradation to higher standards of testing. The NABL accreditation  for  this  test  laboratory  is  the  icing  on  the  cake,  and  allows  us  to  certify  our  test results with authority that very few laboratories across India can match.  The testing is usually done as per IEC 17025:2000, but we have the capability  to test as per the customer’s requirements for any other local standard also.  Add  the  low  turnaround  time  for  sample  testing,  the  precise  and  accurate  results, and the record maintenance; the high demand from our customers is  making  us  almost  approach  the  end  of  spare  capacity.  The  plan  hence  is  to  replicate  the  high  standards  of  Oil  testing  and  set  up  a  couple  more  of  regional laboratories across India and Mid‐East.        Tests profile  Sr.  Tests  IEC  ASTM  IS  1  Color & Appearance  ISO 2049  D‐1524  IS 335  2  Breakdown Voltage  IEC 60156  D‐877  IS 6792  3  Water Content  IEC 60814  D‐1533 B  IS 13567  4  Acidity (Neutralization Value)  IEC 62021  D‐974  IS 1448 [P‐2]  5  Dielectric Dissipation Factor  IS 6262  IEC 60247  D‐924  6  Resistivity  IS 6103  7  Sediments & Sludge  IEC 61125  D‐1524  IS 1866  8  Interfacial Tension  ISO 6295  D‐971  IS 6104  9  Flash Point  IEC 2719  D‐92  IS 1448  10  Pour Point  ISO 3016  D‐97  IS 1448  11  Density  IEC 60814  D‐1298  IS 1448  12  Kinematic Viscosity  ISO 3104  D‐445  IS 1448 [P‐25]  13  Dissolved Gas Analysis  NA  D‐3612‐A  IS 9434  15  Furan Analysis   IEC 61198  D‐5837  ‐‐‐  D-24, Classic Indl Premises, Timely & Correct Diagnosis saves efforts & money MIDC Ambad, Nasik – 422010, MH, India. Tel : +91 253 6602387 Trust the experts!! Fax : +91 253 6602388 Email : contact@powerelectronical.com
  2. 2. POWER ELECTRONICAL Oil Testing Experts http://www.powerelectronical.com/    NABL Accreditation  Power  Electronical’s  TOTL  has  been  certified  for  Transformer  Oil testing  by  NABL  (T‐1424).  It  is  only  one  of  the  few  private  labs  in India to be accorded this status. The NABL accreditation allows our customers  to  be  able  to  compare  and  use  the  test  readings  to  a scale  comparable  with  National  test  laboratories.  It  is  also  a  proof of  our  unswerving  commitment  to  highest  levels  of  quality standards for Oil testing. Under NABL, the following parameters are under  periodic  scrutiny,  thus  allowing  our  customers  to  work peacefully while we work for them 24X7  ‐ our facilities  ‐ test procedurals, and,  ‐ record maintenance                   ISO 9001 : 2000 Certification    We believe International systems accreditation contributes to our  better working and better quality of service for our customers.  Power  Electronical’s  TOTAL  has  been  certified  ISO  9001:2000  compliant  for  its  procedures  and  Quality  management  systems  Transformer Oil testing by TUV SUD.     Certificate Regn No – 99 100 03494 valid until 23 Jan 2011    These  certificates  only  prove  our  systems,  calibration  and  testing  standards.  But,  it  is  our  response  system  and  the  services  we  render to our customers, that allows us to scale higher echelons of  reputation.      D-24, Classic Indl Premises, Timely & Correct Diagnosis saves efforts & money MIDC Ambad, Nasik – 422010, MH, India. Tel : +91 253 6602387 Trust the experts!! Fax : +91 253 6602388 Email : contact@powerelectronical.com
  3. 3. POWER ELECTRONICAL Oil Testing Experts http://www.powerelectronical.com/   Condition Monitoring Services  Testing  is  only  half  the  work  done….without  correct  and  accurate  analysis,  it  serves  no  worthwhile  purpose.  Our  engineers  and  laboratory  staff  are  well  equipped  with  knowledge  and  experience  to  be  able  to  analyze  the  results  and  predict  any  kind  of  rapid  degradation of Oil parameters, or advise residual life expectancy or fault interpretation. We follow it up with site visit and testing of  other  parameters  of  your  equipment,  to  confirm  the  assessment,  and help  the  customer  take preventive  and corrective  measures  well within time. A maintenance contract signed with us for all your critical equipment gives you complete peace of mind, because  we look after them 24X7 thereafter, including scheduled and emergency visits.    Convenience with TOTL association    • Test results provided within 3 working days from sample receipt  • Urgent testing provision at additional 25% charge. Test result provided within 1 working day  • Logistic control and handling may be done by TOTL, on customer’s request  • All tests done under controlled temperature and humidity, to maintain test integrity  • All testing data records maintained for a period of 6 years  • Statistical trending & analysis, on request  • Experienced persons handling test operations, on continual basis since past 5 years  • Single point communication window established for all customers  • Volume discount available to special customers with committed volumes  • Credit limits for special customers, post 6 months of association    Sample Procedure & Costs    • Sampling will be done by our person. Travelling to & fro charges from Nasik will be to customer’s account.  • Customer can issue sampling bottles from us, and do their sampling themselves. To & fro logistics cost of bottles, including  taxes/custom levies will be to customer’s account.  • Sampling bottle may be provided on request. Deposit per bottle is 7500 INR (150US$), on refundable basis.  • Test results will be provided by email. For any paper copy requirement, shipping within India is free, but outside India is to  customer’s account.          Contact  PE‐TOTL  for  world  class  Transformer  Oil  Testing  services,  exclusively at TOTL@powerelectronical.com              Note  –  Power  Electronical  reserves  the  right  to  change  service  specifications  for  continual  improvement.  Please  order  a  fresh  copy  of  service  contract  from  contact@powerelectronical.com, before placing new orders. Jurisdiction limits within territory of Republic of India only. Our other Products are –   • Automatic Cap & Tan Delta test system 10kV / 12kV  • Automatic Oil Resistivity & DF tester  • Manual C&DF test system 12kV  • Insulation Testers (10M to 15T, 2% accuracy)  • Auto Oil Breakdown Voltage Tester 80kV / 100kV  • High Voltage Breakdown testers (10kV‐50kV)  • Motorised Oil BDV set 0‐100kV  • SF6 Gas filled Standard Capacitors (upto 1000kV)  D-24, Classic Indl Premises, Timely & Correct Diagnosis saves efforts & money MIDC Ambad, Nasik – 422010, MH, India. Tel : +91 253 6602387 Trust the experts!! Fax : +91 253 6602388 Email : contact@powerelectronical.com

Power Electronical provides Transformer Oil Testing and Oil Analysis services. Our lab is NABL accreditated, and provide IEC/IS/ASTM standard test services.